rapidly being replaced by automatic devices. This valve is still used in large system as
by pass valve around automatic control valve to allow operation in case of automatic
valve failure and during repairs. Some flooded evaporator control system also as a hand
expansion valve, For trotting and for liquid control. These have a float switch and
solenoid as the over riding control.
load does not interfere at the acceptable winding temperature over its entire operating
range.
FILTER DRIER
Filter drier are highly capable of keeping the system to low level of dryness. The
excellent quality of desiccants used which have the best properties to remove moisture,
acid and foreign contaminants. The incorporate brass screen and phospher bronze
screen in let and out let side for effective filtration of course and fine impurities as small
as 20 microns. The conical spring compresses the desiccant to such extent that the
individual particles cannot more during the passage of the refrigerant thus eliminating
the possibility of power formation. All internal parts are rust and heat resistant and are
unaffected during brazing of drier with system. Filter drier are principally used on
Refrigeration and Air conditioning system because of their excellent filtering, During
and acid removing characteristics. They are available in two type of desiccants i.e.
Molecular sieves Silica gel.
RECEIVER VALVE
This can be used for to fill the refrigerant gas or to use for to discharge the refrigerant
from cylinder/ receiver.
PTC RELAY
PTC relay is the need for improved or higher starting torque on some typical occasions
where PSC applied compressors are expected to start at extreme low voltage or under
circumstances beyond normal start conditions PTC start Assist Device is not introduce
to replace the difference combination of CSR electrical accessories Viz. Start capacitor
and start relay currently used on PSC design compressor.
INDUSTRIAL THERMOSTAT
The purpose of industrial thermostat is same as Refrigerant Thermostat. The industrial
Thermostat is used mostly in plant Air Conditioning.
current element which is a bimetallic strip disconnect the supply to the motor when
excessive current is taken by the motor. Bimetallic strip and the contacts are broken.
DISCHARGE VALVE
This valve is divides the compressor from the rest of the system for that the machine
may be shut down and worked on without interference from refrigerant.
stop the compressor when pressure (and therefore temperature) conditions have been
satisfied. These controls also have an adjustable range and differential.
STARTING CAPACITOR
It gives starting torque to the motor and cut off after running the motor.
RUNNING CAPACITOR
The function of the running capacitor is to give regular torque to the FHB motor or split
phase induction run motor. It connected in paralleled.
Y TYPE STRAINER
The function of the Y type strainer is to prevent foreign practical going to the expansion
valve. The Y type strainer fixed in the liquid line of the package Air Conditioner,
Central & other industrial & commercial air conditioners.
SUCTION GAUGE
The function of the suction gauge is to show the low side pressure of the system. It
works on spring tension as shown in equipment fitted on the board.
PRESSURE GAUGE
The function is to show high pressure of the system in terms of Kg/cm2 or Bar.
CHECK VALVE
The function of the check valve is to prevent the liquid into the line. It works on
pressure of the liquid. The spring lift up when pressure exists and allow liquid to pass
and prevent the way when pressure drop. It is also called saving device.
ANGLE VALVE
Angle valve on the liquid line located between the liquid shut off valve and the strainer
is very helpful in charging the system with liquid refrigerant. All these valves have seal
caps with seal washers to prevent any leakage of the refrigerant through the gland of the
valve stem. The flare ends should be capped in the angle valves provided for servicing
purpose.
HEAT EXCHANGERS
A heat exchanger may be defined as equipments, which transfers the energy from a hot
fluid with maximum rate and minimum investment and running cost. In heat
exchangers the temperature of each fluid changes as it passes through the exchangers
and hence the temperature of dividing wall between the fluids also changes along the
length of the exchanger.
OIL SEPERATOR
Oil separator is provided on the hot gas line to arrest oil carried by the refrigerant hot
gas from the compressor. Like in the accumulator, the heavier oil drops down into the
oil separator shell because of the low gas velocity in the shell. Oil catching screens or
centrifugal separation is also adopted. Oil separator is a must where oil is not miscible
with refrigerant (e.g. ammonia).
BALANCING VALVE
Balancing valves are used in the refrigerant cycle where we have to maintain the
temperature and pressure of two evaporators through the single compressor. The gauges
are also fixed in the balancing valve. So that we can adjust the pressure of the liquid
refrigerant while checking the gauges.
BALL VALVE
Ball valve are used in the air conditioning. It is hand-operated valve, which opens the
way of the refrigerant/water/liquid while flowing.
BUTTERFLY VALVE
Butterfly valve is hand-operated valve, which is commonly used in the by-pass lines of
water-cooled condenser/chiller (evaporators) and maintain and control the supply water.
We can control the supply of water to these water- cooled condensers/evaporators
immediately because these is no hand wheel on it.
2 WAY HAND SHUT OFF VALVE These valves are used in refrigerant and airconditioning cycle to close/open (on-off) the supply of refrigerant. It can be used at
various different places in the refrigerant cycle as per our requirement. It can also be
used as increase/or decrease the flow rate of liquid refrigerant.
GATE VALVE
Gate valve is hands operated valves and are used in the by-pass line of water-cooled
condensers/or chiller evaporator to control and regulate the supply of water. The supply
of water can easily be controlled by just revolving down the spindle fixed on the head
of gate valve.
the liquid flows and produces the necessary pressure drop. In operation it is not
automatic and therefore the valve has to be manually adjusted every time the load
changes.
AMMONIA HAND SHUT OFF VALVE
Ammonia hand shut off valves are used in NH 3 air-conditioning where it is used to
control and regulate the supply of NH3 (refrigerant). It is also used as open- close (onoff) the supply of the refrigerant.
COMPRESSOR SEAL
In open type compressor at a point, where the shaft comes out of the compressor body,
there must be a sealing arrangement around the shaft to prevent the leakage of the
refrigerant.
FLARE FITTING
Flared joints can be employed only with soft copper pipes. The ends of the pipes are
flared by the use of the flaring tool. Sizes of countersunk holes for taking in the copper
pipes of to diameter.
SOLDER CONNECTION FITTING
Solder or brazed method gives a stronger joint. These joints, If properly done are much
susceptible of developing leaks compared to the threaded flair joints. Hence this method
is extensively adopted for refrigeration units and air conditioning plants.
AMMETER
Ammeter is used to measure the current flow or ampere in a circuit. The coil in the
ammeter is of very low resistance and is always connected in series with the load,
which necessitates interrupting a connected load circuit.
VOLTMETER
A voltmeter shows the voltage or potential across a circuit. The coils of these meters are
of high resistance and should be connected in parallel (across the load).
ENERGY METER
The Energy meter is used to measure the power in the watts or kilowatts. Since power is
the product of voltage, current and power factor, both voltage and ammeter connections
are to be made to the wattmeter. Wattmeter in conjunction with potential and current
transformers are used to measure higher ranges of power (watts).
REVERSING SWITCH
Reversing switch is used as a phase changer. It is used with the generator and in the
main line.
ROTARY SWITCH
Rotary switch is used a phase changer and also acts as a speed controller.
wherever possible, eliminates the foaming problem at the start up. The heaters used are
of very low wattage (40 to 60W for to 60 ton compressors) and are not capable of
increasing oil temperature to a high level.
A/C HEATER
For winter heating applications, a hot water or steam heating coil is also provided in the
air-handling units. Instead of the heating coils, electrical strip heaters are also used for
heating the air when the air is heated, its relative humidity will obviously fall. So for
maintaining a proper relative humidity level, humidification of the air is also required.
KETTLE ELEMENT
Kettle element is used in boilers and used for heating the water according to the
requirement. While using the kettle element, it should merge with in the water only
otherwise the element burns out.
DUCT HEATERS
Duct heaters are the type of heaters, which are, used inside the duct of further increases
the humidity of the air. Humidification plants are extensively used for textile mills,
tobacco bulk storage, tea processing etc. Where high relative humidity levels are
required.
increasing the evaporator pressure till the desired evaporator pressure is reached. On the
other hand when the evaporator pressure rises, the diaphragm moves upwards to reduce
the opening of the valve. This decreases the flow of liquid refrigerant to the evaporator
which, in turn, lowers the evaporator pressure till the desired evaporator pressure is
reached.
When the compressor stops, the liquid refrigerant continues to flow into the
evaporator. This increase in evaporator pressure causes the diaphragm to move upwards
and the valve is closed. It remains closed until the compressor starts again and reduces
the pressure in the evaporator.