Sunteți pe pagina 1din 8
LV. AL NAKHEEL METALS construction contracting www.nakheelmetals.com @ facebook.com/nakheelmetals CRB elec © Steel & Cladding Erection e Sliding Door © Cold Rooms CRG re ene cotald Mob. : +971 50 850 8883 | Office No : A18 | ABC Building Industrial Area 2 | Ajman - U.A.E. E-mail: sales@nakheelmetals.com STEEL BUILDINGS Basic Building Parameters AL NAKHEEL METALS Construction contracting Steel Buildings are defined by the basic parameters like Building Width, Building Length, Building Height, Roof Slope, End Bay Length, Interior Bay Length and Design Loads. Find below what these parameters mean does. Building Width Itis defined as the distance from outside of the eve strut of ‘one sidewall to the outside eve strut of opposite sidewall, Building Length ‘This is the distance between outer flanges of the endwall columns in the opposite endwalls. It is a combination of several bay lengths. End Bay Length This is the distance from outside of the outer flange of endwall columns to the centre line of the first interior column, Interior Bay Length This is the distance between centre lines of two adjacent L interior main frame columns. The most common bay : lengths are 6, 8 & 12 meters, ccs omun enesur th 5 3 1 ¥ g : rruseeD con : , 1 tee i L sono wor u STANDARD FRAME SECTION Building Height Roof Slope Building, height is the eve height which is usually the distance from the bottom of main frame base plate (Usually Finished Floor Level) to the top of the outer point of the eve strut. It is defined as the angle of roof with respect to the horizontal, usually mentioned asx /10 or x /20. Any practical roof slope is possible but most common roof slope are 0.5/10 and 1/10. STEEL SUB - STRUCTURES SIDEWALL ROOF EXTENSION CANOPY Mezzanine Systems Standard Mezzanine floor systems consist of Galvanized Steel Decking supported by joints framed onto main m¢ nine beams. A reinforced concrete slab is cast in situ on top of the metal deck. (by Civil Contractors). JOIST CONNECTION @ INTERMEDIATE BEAM AL NAKHEEL METALS Construction contracting ROOF PLATFORM ‘MEZZ. BEAM CONNECTION TO RIGID FRAME COLUMN JOIST TO BEAM CONNECTION @ END WALL AL NAKHEEL METALS Construction contracting STEEL SUB - STRUCTURES PARAPET FASCIA VERTICAL FASCIA WITH BACK-UP PANEL & VALLEY GUTTER CURVED EAVE DETAIL WITH PROJECTION CURVED EAVE DETAIL WITHOUT PROJECTION AL NAKHEEL METALS Construction contracting STEEL SUB - STRUCTURES ELEVATION SINGLE FLIGHT STAIRCASE WITH TOP LANDING ELEVATION DOUBLE FLIGHT STAIRCASE CAGE LADDER AL NAKHEEL METALS Construction contracting PURLINS - SECTIONAL DETAILS 4 and Px (opposite hand) 3 ver ena # Teariante 33 Jovernang, Centre tine of rafters 4 Centre ine of raters ” 0 o gle oo 1 Es in toe a | coteoe aq) oe 7 UU OF ; if tie Cae. th — Feb tH aoe A =f of AL NAKHEEL METALS Construction contracting AL NAKHEEL METALS Mob. : +971 50 850 8883, Office No: A18, ABC Building Industrial Area 2, Aiman - U.A.E. www. nakheelmetals.com facebook. com/nakheelmetas E-mail: sales@nakheelmetals. com construction contracting

S-ar putea să vă placă și