Sunteți pe pagina 1din 19

Instrumentation Cables

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
300V PVC Insulated, PVC Jacketed ITC Rated
Applications and Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overall Shielded Pairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overall Shielded Triads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Individual and Overall Shielded Pairs . . . . . . . . . . . . . . . . . . . . . . .
Individual and Overall Shielded Triads . . . . . . . . . . . . . . . . . . . . . .

3
4
5
6
7

600V PVC/Nylon Insulated, PVC Jacketed TC Rated


Applications and Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Overall Shielded Pairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Overall Shielded Triads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Individual and Overall Shielded Pairs . . . . . . . . . . . . . . . . . . . . . . 11
Individual and Overall Shielded Triads . . . . . . . . . . . . . . . . . . . . . 12

Technical Information
Electrical Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Belden Cross-Reference by Part Number . . . . . . . . . . . . . . . . . . 14-15
Belden Cross-Reference by Description . . . . . . . . . . . . . . . . . . . . 16-17
Product and Copper Conductor Data . . . . . . . . . . . . . . . . . . . . . . 18

Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

1-866-6-NEXANS
1

Introduction
Nexans is one of the largest wire
and cable manufacturers in the
world, and in North America. In
North America we manufacture in
locations across the United States
and Canada. We design and
produce a wide range of cables
used in power, industrial,
construction and communication
applications.
With more than nine decades of
experience as a leader in the
industrial and power cable markets,
Nexans is contracted by heavy
industry and utilities world wide to
provide turnkey solutions for the
bulk transmission of power from
generating station through the
distribution system to commercial
and residential areas.
This catalogue has been prepared
for the convenience of those using
electrical conductors in industrial
applications.

It presents the important data


pertaining to the various types of
wires and cables in readily
obtainable form. We believe that
the information included in the
many tabulations will be of
particular value to the architect,
engineer, electrician, and layperson
alike.
Although we have listed herein the
types of wires and cables suitable
for most conditions, we are
equipped to manufacture other
types to suit special needs. We
would be pleased to recommend
the most suitable construction for
any special condition that you may
encounter.
The determination of the correct
cable size and type, and the
selection of methods of installation
suitable for the type and location of
particular circuits, should be made
in accordance with local
regulations. Any questions in this
respect should be directed primarily
to the local Electrical Inspection
Authority.

1-866-6-NEXANS
2

Instrumentation Cable
300V, PVC Insulated, 105C
Unshielded Pairs or Triads with Overall Shield
Shielded Pairs or Triads with Overall Shield
Type PLTC UL 13 NEC ART 725
Type ITC UL 2250 NEC ART 727
Applications

Pairs: black/white and number coded


Triads: black/white/red and number
coded

As indicated in UL 13 and 2250: The


overall jackets of these cables are a
gas/vapour tight continuous sheath
as discussed in NEC Sections
501.5(D) and 501.5(E).*
For use under raised floors in control
rooms when arranged in such a
fashion as to prevent damage to the
cables.
In Class 2 and Class 3 Circuits, as
defined in NEC ART 725 for Type
PLTC cables.

Bending Radius

Options

Insulation: polyvinyl chloride in


accordance with UL 13 and UL 2250,
flame retardant, 105C temperature
rating.

Fixed Position: 5 x cable overall


diameter
During Installation: 8 x cable
overall diameter

Insulation Shield (on shielded pair/


triad constructions): aluminum foil/
polyester shield helically wrapped to
provide 100% coverage with a tinned
copper drain wire that is two gauge
sizes smaller than the circuit
conductors.

Specifications

The following constructions can be


provided on special orders:
Tinned copper conductors
When increased mechanical,
chemical, or environmental
protection is required, cables can be
supplied with a continuously
corrugated aluminum armor and an
outer PVC jacket.
Interlocked aluminum armor with or
without an outer PVC jacket.
Direct Burial listed cable (when
ordered as ITC/DB)
Conductors with alternate color /
identification codes
Alternate jacket colors

The 300V Instrumentation Cables are


dual listed as Type PLTC per UL 13 and
Type ITC per UL 2250. These cables
are suitable for installations as outlined
in NEC ART 725 for Type PLTC cables
and NEC ART 727 for Type ITC cables.

Construction
Conductor: bare, annealed copper
conforming to ASTM B-3 and Class B
stranded in accordance to ASTM B-8.

Assembly: pairs/triads are cabled in


concentric layers. In the case of
unshielded pairs/triads, they are
cabled at staggered lengths to reduce
crosstalk.
Overall cable shield: aluminum
foil/polyester shield helically wrapped
to provide 100% coverage with a
tinned copper drain wire that is the
same size as the circuit conductors,
with the exception of single pair/triad
constructions where the drain wire is
two gauge sizes smaller than the circuit
conductors.

Jacket: UL listed sunlight and


moisture resistant, sequentially length
marked, black, flame retardant
polyvinyl chloride material. A Nylon
ripcord is included for ease of jacket
removal.

Conductor Identification

Conductor rated 105C 300V


Meets UL requirements for Type PLTC
and ITC
Designated Type PLTC per NEC ART
725
Designated Type ITC per NEC ART
727

Product Features
UL approved Type PLTC and ITC,
300V
UL approved insulated conductors
Cables pass UL 1685 and IEEE 383
vertical fire tests at 70,000 BTU/hr
Temperature rating 105C dry
Sunlight and moisture resistant jacket
For use within Class 1 Division 2 and
Class 2 Division 2 Hazardous
Locations, and Intrinsically Safe
applications as permitted by NEC
ART 392, 501, 502, 504 and 505.*

1-866-6-NEXANS
3

* Use in hazardous locations:


Please note that no investigation of
these cables has been performed
regarding the transmission of gases or
vapours through the core. When these
cables are used in hazardous locations
they should be sealed properly as
required by the NEC.

Instrumentation Cable
300V, PVC Insulated, 105C, Overall Shield
UL 13 Type PLTC NEC ART 725
UL 2250 Type ITC NEC ART 727
Unshielded Pairs with an Overall Shield (POS), 300V
Part
Number

# of
Pairs

Cond.
Size
AWG

Insulation
Thickness
mils
mm

Jacket
Thickness
mils
mm

Nominal Diameter Approximate Net


over Jacket
Cable Weight
inches
mm
lb/kft
kg/km

lb

kg

669606

671206
671219

671180
671305
676494
671313
671339
671347

1
2
4
8
10
12
16
20
24
36
50

20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)

12
12
12
12
12
12
12
12
12
12
12

.30
.30
.30
.30
.30
.30
.30
.30
.30
.30
.30

37
37
42
52
52
52
62
62
62
72
72

.94
.94
1.07
1.32
1.32
1.32
1.57
1.57
1.57
1.83
1.83

.212
.264
.353
.485
.529
.570
.662
.726
.783
.951
1.095

5.38
6.71
8.97
12.32
13.44
14.48
16.81
18.44
19.89
24.16
27.81

27
49
74
133
158
182
243
291
338
495
658

40
73
110
198
235
271
362
433
503
737
979

25
40
74
140
172
205
270
336
401
598
828

11
18
34
64
78
93
122
152
182
271
376

669614
669739
671123
669633

671115
676411

671107
671099
671065

1
2
4
8
10
12
16
20
24
36
50

18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)

15
15
15
15
15
15
15
15
15
15
15

.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38

37
42
52
52
52
62
62
62
72
72
72

.94
1.07
1.32
1.32
1.32
1.57
1.57
1.57
1.83
1.83
1.83

.230
.302
.413
.541
.592
.659
.742
.851
.901
1.071
1.236

5.84
7.67
10.49
13.74
15.04
16.74
18.85
21.62
22.89
27.20
31.39

34
67
105
176
211
257
326
393
476
675
901

51
100
156
262
314
382
485
585
708
1005
1341

39
64
116
220
271
323
426
530
633
944
1306

18
29
53
100
123
147
193
240
287
428
592

669580
671156
671198
671164

671172
672220

671297
671131
671149

1
2
4
8
10
12
16
20
24
36
50

16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)

15
15
15
15
15
15
15
15
15
15
15

.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38

37
42
52
62
62
62
62
72
72
72
82

.94
1.07
1.32
1.57
1.57
1.57
1.57
1.83
1.83
1.83
2.08

.254
.339
.464
.633
.693
.748
.844
.949
1.026
1.224
1.437

6.45
8.61
11.79
16.08
17.60
19.00
21.44
24.10
26.06
31.09
36.50

47
91
142
256
307
357
454
570
667
956
1314

70
135
211
381
457
531
676
848
993
1423
1955

62
103
268
350
433
516
681
846
1011
1507
2085

28
47
122
159
196
234
309
384
459
684
946

Note: Specifications and weights shown are nominal and subject to standard industry tolerances.

1-866-6-NEXANS
4

Pulling Tension

Instrumentation Cable
300V, PVC Insulated, 105C, Overall Shield
UL 13 Type PLTC NEC ART 725
UL 2250 Type ITC NEC ART 727
Unshielded Triads with an Overall Shield (TOS), 300V
Part
Number

# of
Triads

Cond.
Size
AWG

Insulation
Thickness
mils
mm

Jacket
Thickness
mils
mm

Nominal Diameter Approximate Net


over Jacket
Cable Weight
inches
mm
lb/kft
kg/km

lb

kg

669747

1
2
4
8
10
12
16
20
24
36
50

20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)

12
12
12
12
12
12
12
12
12
12
12

.30
.30
.30
.30
.30
.30
.30
.30
.30
.30
.30

37
42
52
52
62
62
62
62
72
72
82

.94
1.07
1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
2.08

.222
.357
.433
.556
.670
.690
.765
.849
.963
1.099
1.312

5.64
9.07
11.00
14.12
17.02
17.53
19.43
21.56
24.46
27.91
33.32

33
70
107
181
233
266
336
406
496
698
961

49
104
159
269
347
396
500
604
738
1039
1430

33
57
106
204
254
303
401
500
598
893
1238

15
26
48
93
115
137
182
227
271
405
562

669622

675256
675215

1
2
4
8
10
12
16
20
24
36
50

18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)

15
15
15
15
15
15
15
15
15
15
15

.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38

37
52
52
62
62
62
62
72
72
72
82

.94
1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
1.83
2.08

.242
.413
.476
.635
.741
.764
.849
.963
1.070
1.224
1.462

6.15
10.49
12.09
16.13
18.82
19.41
21.56
24.46
27.18
31.09
37.13

42
96
141
254
311
358
454
571
674
958
1321

63
143
210
378
463
533
676
850
1003
1426
1966

51
90
168
323
401
478
633
789
944
1410
1953

23
41
76
147
182
217
287
358
428
640
886

669598

687907
671321

688093

1
2
4
8
10
12
16
20
24
36
50

16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)

15
15
15
15
15
15
15
15
15
15
15

.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38

37
52
52
62
62
62
72
72
72
82
92

.94
1.32
1.32
1.57
1.57
1.57
1.83
1.83
1.83
2.08
2.34

.267
.460
.533
.713
.836
.863
.981
1.089
1.212
1.410
1.681

6.78
11.68
13.54
18.11
21.23
21.92
24.92
27.66
30.78
35.81
42.70

58
126
192
352
432
500
661
807
954
1396
1923

86
188
286
524
643
744
984
1201
1420
2077
2862

82
144
268
516
639
763
1011
1259
1507
2250
3117

37
65
122
234
290
346
459
571
684
1021
1414

Note: Specifications and weights shown are nominal and subject to standard industry tolerances.

1-866-6-NEXANS
5

Pulling Tension

Instrumentation Cable
300V, PVC Insulated, 105C, Individual and Overall Shield
UL 13 Type PLTC NEC ART 725
UL 2250 Type ITC NEC ART 727
Shielded Pairs with an Overall Shield (SPOS), 300V
Part
Number

# of
Pairs

Cond.
Size
AWG

Insulation
Thickness
mils
mm

Jacket
Thickness
mils
mm

Nominal Diameter Approximate Net


over Jacket
Cable Weight
inches
mm
lb/kft
kg/km

lb

kg

669705
669820
669697

671263
671362

671370
671388
671396

2
4
8
10
12
16
20
24
36
50

20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)

12
12
12
12
12
12
12
12
12
12

.30
.30
.30
.30
.30
.30
.30
.30
.30
.30

42
52
52
62
62
62
62
72
72
82

1.07
1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
2.08

.349
.423
.543
.654
.674
.747
.827
.939
1.071
1.278

8.86
10.74
13.79
16.61
17.12
18.97
21.01
23.85
27.20
32.46

66
101
170
220
250
316
382
466
655
902

98
150
253
327
372
470
568
693
975
1342

52
96
184
228
272
360
448
536
800
1108

24
44
83
103
123
163
203
243
363
503

669671
669689
669721

669713
671404

671412
671420
671081

2
4
8
10
12
16
20
24
36
50

18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)

15
15
15
15
15
15
15
15
15
15

.38
.38
.38
.38
.38
.38
.38
.38
.38
.38

52
52
62
62
62
62
72
72
72
82

1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
1.83
2.08

.382
.443
.577
.720
.743
.824
.935
1.038
1.187
1.417

9.70
11.25
14.66
18.29
18.87
20.93
23.75
26.37
30.15
35.99

84
121
211
285
327
415
521
614
870
1201

125
180
314
424
487
618
775
914
1295
1787

81
149
285
353
421
558
694
830
1239
1716

37
68
129
160
191
253
315
376
562
778

671222
671230
671248

671255
671438

671446
671453
671487

2
4
8
10
12
16
20
24
36
50

16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)

15
15
15
15
15
15
15
15
15
15

.38
.38
.38
.38
.38
.38
.38
.38
.38
.38

52
52
62
62
62
72
72
72
82
82

1.32
1.32
1.57
1.57
1.57
1.83
1.83
1.83
2.08
2.08

.446
.516
.690
.808
.834
.948
1.053
1.171
1.362
1.603

11.33
13.11
17.53
20.52
21.18
24.08
26.75
29.74
34.59
40.72

120
174
317
388
449
592
721
852
1245
1684

179
259
472
577
668
881
1073
1268
1853
2506

129
237
454
537
671
888
1105
1322
1972
2731

59
108
206
244
304
403
501
600
894
1239

Note: Specifications and weights shown are nominal and subject to standard industry tolerances.

1-866-6-NEXANS
6

Pulling Tension

Instrumentation Cable
300V, PVC Insulated, 105C, Individual and Overall Shield
UL 13 Type PLTC NEC ART 725
UL 2250 Type ITC NEC ART 727
Shielded Triads with an Overall Shield (STOS), 300V
Part
Number

# of
Triads

Cond.
Size
AWG

Insulation
Thickness
mils
mm

Jacket
Thickness
mils
mm

Nominal Diameter Approximate Net


over Jacket
Cable Weight
inches
mm
lb/kft
kg/km

lb

kg

693770
693788

693796
693804

2
4
8
10
12
16
20
24
36
50

20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)

12
12
12
12
12
12
12
12
12
12

.30
.30
.30
.30
.30
.30
.30
.30
.30
.30

42
52
52
62
62
62
62
72
72
82

1.07
1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
2.08

.357
.433
.556
.670
.690
.765
.849
.963
1.099
1.275

9.07
11.00
14.12
17.02
17.53
19.43
21.56
24.46
27.91
32.39

77
122
212
272
313
399
485
591
841
1155

115
182
315
405
466
594
722
880
1252
1719

68
128
249
310
370
491
612
732
1095
1518

31
58
113
141
168
223
278
332
497
689

669495
676403

671054

671040
669929

2
4
8
10
12
16
20
24
36
50

18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)

15
15
15
15
15
15
15
15
15
15

.38
.38
.38
.38
.38
.38
.38
.38
.38
.38

52
52
62
62
62
62
72
72
72
82

1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
1.83
2.08

.431
.476
.635
.741
.764
.849
.963
1.070
1.224
1.420

10.95
12.09
16.13
18.82
19.41
21.56
24.46
27.18
31.09
36.07

108
160
293
360
416
533
671
793
1137
1565

161
238
436
536
619
793
999
1180
1692
2329

106
200
389
483
577
765
953
1141
1705
2363

48
91
176
219
262
347
432
518
773
1072

671271
671693

672063

631846

2
4
8
10
12
16
20
24
36
50

16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)

15
15
15
15
15
15
15
15
15
15

.38
.38
.38
.38
.38
.38
.38
.38
.38
.38

52
52
62
62
62
72
72
72
82
82

1.32
1.32
1.57
1.57
1.57
1.83
1.83
1.83
2.08
2.08

.460
.533
.713
.836
.863
.981
1.089
1.212
1.410
1.613

11.68
13.53
18.11
21.23
21.92
24.92
27.66
30.78
35.81
40.97

146
221
410
504
587
777
953
1130
1660
2252

217
329
610
750
874
1156
1418
1682
2470
3351

170
320
619
769
919
1218
1518
1817
2715
3764

77
145
281
349
417
552
689
824
1232
1707

Note: Specifications and weights shown are nominal and subject to standard industry tolerances.

1-866-6-NEXANS
7

Pulling Tension

Instrumentation Cable
600V, PVC/Nylon Insulated, 90C
Unshielded Pairs or Triads with Overall Shield
Shielded Pairs or Triads with Overall Shield
Type TC UL 1277 NEC ART 336
Applications

Conductor Identification

The 600V Instrumentation Cables are


listed as Type TC per UL 1277. These
cables are suitable for installations as
outlined in NEC ART 336.

Pairs: black/white and number coded


Triads: black/white/red and number
coded

Construction
Conductor: bare, annealed copper
conforming to ASTM B-3 and Class B
stranded in accordance to ASTM B-8.
Insulation: PVC/Nylon Type TFN in
accordance with UL 62, flame
retardant, 90C temperature rating.
Insulation Shield (on shielded pair/
triad constructions): aluminum foil/
polyester shield helically wrapped to
provide 100% coverage with a tinned
copper drain wire that is two gauge
sizes smaller than the circuit
conductors.
Assembly: pairs/triads are cabled in
concentric layers. In the case of
unshielded pairs/triads, they are
cabled at staggered lengths to reduce
crosstalk.
Overall cable shield: aluminum
foil/polyester shield helically wrapped
to provide 100% coverage with a
tinned copper drain wire that is the
same size as the circuit conductors,
with the exception of single pair/triad
constructions where the drain wire is
two gauge sizes smaller than the circuit
conductors.

Bending Radius
Fixed Position: 5 x cable overall
diameter
During Installation: 8 x cable
overall diameter

Specifications
Meets UL 62, TFN rated 90C 600V
conductors
Meets UL requirements for Type TC
Designated Type TC per NEC ART
336

Product Features
UL approved Type TC, 600V
UL approved insulated conductors
Cables pass UL 1685 and IEEE 383
vertical fire tests at 70,000 BTU/hr
Temperature rating 90C dry, 75C
wet
Sunlight and moisture resistant jacket
For use within Class 1 Division 2 and
Class 2 Division 2 Hazardous
Locations, and Intrinsically Safe
applications as permitted by NEC
ART 392, 501, 502, 504 and 505.*
As indicated in UL 1277: The overall
jackets of these cables are a gas/
vapour tight continuous sheath as
discussed in NEC Sections 501.5(D)
and 501.5(E).*

Jacket: UL listed sunlight and moisture


resistant, sequentially length marked,
black, flame retardant polyvinyl
chloride material. A Nylon ripcord is
included for ease of jacket removal.

1-866-6-NEXANS
8

Cables are rated for Direct Burial


applications
For use in cable trays, raceways,
conduit or for aerial applications
where installed with a messenger
Cables may be used In Class 1
Circuits, as defined in NEC Section
336.10 and ART 725 for Type TC
cables
Cables may also be used as
permitted for nonpower-limited fire
alarm circuits as defined in NEC
Sections 336.10 and 760.27
The Nylon jacket over the PVC
insulation provides excellent oil and
gasoline protection

Options
The following constructions can be
provided on special orders:
Tinned copper conductors
When increased mechanical,
chemical, or environmental
protection is required, cables can be
supplied with a continuously
corrugated aluminum armor and an
outer PVC jacket.
Interlocked aluminum armor with or
without an additional outer PVC
jacket
Conductors with alternate color/
identification codes
Alternate jacket colors

* Use in hazardous locations:


Please note that no investigation of
these cables has been performed
regarding the transmission of gases or
vapours through the core. When these
cables are used in hazardous locations
they should be sealed properly as
required by the NEC.

Instrumentation Cable
600V, PVC/Nylon Insulated, 90C
Overall Shield
UL 1277 Type TC NEC ART 336
Unshielded Pairs with an Overall Shield (POS), 600V
Part
Number

# of
Pairs

Cond.
Size
AWG

Insulation
Thickness
mils
mm

Jacket
Thickness
mils
mm

Nominal Diameter Approximate Net


over Jacket
Cable Weight
inches
mm
lb/kft
kg/km

lb

kg

669101
631275
631283
697490
627489
627208
697672
627208

697276
627190
631291

1
2
4
6
8
10
12
16
20
24
36
50

18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)

15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4

.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10

47
47
47
62
62
62
62
62
82
82
82
82

1.19
1.19
1.19
1.57
1.57
1.57
1.57
1.57
2.08
2.08
2.08
2.08

.270
.340
.442
.557
.617
.675
.728
.821
.943
1.018
1.209
1.396

6.86
8.64
11.23
14.15
15.67
17.15
18.49
20.85
23.95
25.86
30.71
35.46

42
77
114
162
208
248
286
361
469
544
765
1017

63
115
170
241
310
369
426
537
698
810
1138
1513

39
64
116
170
220
271
323
426
530
633
944
1306

18
29
53
77
100
123
147
193
240
287
428
592

697391
631242
631440
631457

631259
697474
669408
697482
627216
631267

1
2
4
8
10
12
16
20
24
36
50

16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)

15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4

.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10

47
47
47
62
62
62
82
82
82
82
82

1.19
1.19
1.19
1.57
1.57
1.57
2.08
2.08
2.08
2.08
2.08

.294
.377
.494
.690
.756
.817
.964
1.058
1.144
1.354
1.578

7.47
9.58
12.55
17.53
19.20
20.75
24.49
26.87
29.06
34.39
40.08

55
103
152
279
334
388
528
636
745
1057
1417

82
153
226
415
497
577
786
946
1109
1573
2109

62
103
268
350
433
516
681
846
1011
1507
2085

28
47
122
159
196
234
309
384
459
684
946

Note: Specifications and weights shown are nominal and subject to standard industry tolerances.

1-866-6-NEXANS
9

Pulling Tension

Instrumentation Cable
600V, PVC/Nylon Insulated, 90C
Overall Shield
UL 1277 Type TC NEC ART 336
Unshielded Triads with an Overall Shield (TOS), 600V
Part
Number

# of
Triads

Cond.
Size
AWG

Insulation
Thickness
mils
mm

Jacket
Thickness
mils
mm

Nominal Diameter Approximate Net


over Jacket
Cable Weight
inches
mm
lb/kft
kg/km

lb

kg

669119

676676

1
2
4
8
10
12
16
20
24
36
50

18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)

15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4

.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10

47
47
47
62
62
82
82
82
82
82
82

1.19
1.19
1.19
1.57
1.57
2.08
2.08
2.08
2.08
2.08
2.08

.283
.442
.513
.700
.820
.886
.982
1.088
1.208
1.382
1.628

7.19
11.23
13.03
17.78
20.83
22.50
24.94
27.64
30.68
35.10
41.35

51
90
153
282
345
427
538
651
765
1080
1451

76
134
228
420
513
635
801
969
1138
1607
2159

51
90
168
323
401
478
633
789
944
1410
1953

23
41
76
147
182
217
287
358
428
640
886

697888

687228

1
2
4
8
10
12
16
20
24
36
50

16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)

15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4

.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10

47
47
62
62
82
82
82
82
82
82
112

1.19
1.19
1.57
1.57
2.08
2.08
2.08
2.08
2.08
2.08
2.84

.309
.490
.601
.779
.955
.985
1.094
1.214
1.351
1.549
1.887

7.85
12.45
15.27
19.79
24.26
25.02
27.79
30.84
34.32
39.34
47.93

68
120
222
383
503
578
735
893
1055
1505
2142

101
179
330
570
749
860
1094
1329
1570
2240
3188

82
144
268
516
639
763
1011
1259
1509
2250
3117

37
65
122
234
290
346
459
571
684
1021
1414

Note: Specifications and weights shown are nominal and subject to standard industry tolerances.

1-866-6-NEXANS
10

Pulling Tension

Instrumentation Cable
600V, PVC/Nylon Insulated, 90C
Individual and Overall Shield
UL 1277 Type TC NEC ART 336
Shielded Pairs with an Overall Shield (SPOS), 600V
Part
Number

# of
Pairs

Cond.
Size
AWG

Insulation
Thickness
mils
mm

Jacket
Thickness
mils
mm

Nominal Diameter Approximate Net


over Jacket
Cable Weight
inches
mm
lb/kft
kg/km

lb

kg

631358
631366
631374

631382
697532
671735
697540
697557
627919

2
4
8
10
12
16
20
24
36
50

18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)

15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4

.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10

47
47
62
62
62
82
82
82
82
82

1.19
1.19
1.57
1.57
1.57
2.08
2.08
2.08
2.08
2.08

.429
.498
.678
.794
.819
.951
1.053
1.169
1.336
1.572

10.90
12.65
17.22
20.17
20.80
24.16
26.75
29.69
33.93
39.93

96
139
257
314
359
490
592
695
987
1314

143
207
382
467
534
729
881
1034
1469
1955

81
149
285
353
421
558
694
830
1239
1716

37
68
129
160
191
253
315
376
562
778

631309
631317
631325
631333
631341

697508
697516
680405
697524
680413
693564

2
3
4
6
8
10
12
16
20
24
36
50

16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)

15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4

.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10

47
47
62
62
62
82
82
82
82
82
92
112

1.19
1.19
1.57
1.57
1.57
2.08
2.08
2.08
2.08
2.08
2.34
2.84

.480
.514
.590
.694
.763
.937
.966
1.072
1.190
1.323
1.536
1.849

12.19
13.06
14.99
17.63
19.38
23.80
24.54
27.23
30.23
33.60
39.01
46.96

127
145
201
270
344
455
521
660
801
944
1370
1914

189
216
299
402
512
677
775
982
1192
1405
2039
2848

129
183
237
350
454
537
671
888
1105
1322
1972
2731

59
83
108
159
206
244
304
403
501
600
894
1239

Note: Specifications and weights shown are nominal and subject to standard industry tolerances.

1-866-6-NEXANS
11

Pulling Tension

Instrumentation Cable
600V, PVC/Nylon Insulated, 90C
Individual and Overall Shield
UL 1277 Type TC NEC ART 336
Shielded Triads with an Overall Shield (STOS), 600V
Part
Number

# of
Triads

Cond.
Size
AWG

Insulation
Thickness
mils
mm

Jacket
Thickness
mils
mm

Nominal Diameter Approximate Net


over Jacket
Cable Weight
inches
mm
lb/kft
kg/km

lb

kg

689547
631408
631416

697565

631424
697565

2
4
8
10
12
16
20
24
36
50

18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)

15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4

.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10

47
62
62
82
82
82
82
82
82
112

1.19
1.57
1.57
2.08
2.08
2.08
2.08
2.08
2.08
2.84

.453
.557
.718
.882
.909
1.008
1.118
1.242
1.421
1.734

11.51
14.15
18.24
22.40
23.09
25.60
28.40
31.55
36.09
44.04

117
190
327
432
495
628
762
899
1279
1826

170
283
487
643
737
935
1134
1338
1903
2717

106
200
389
483
577
765
953
1141
1705
2363

48
91
176
219
262
347
432
518
773
1072

631390
627133

627141
688648

683029

2
4
8
10
12
16
20
24
36
50

16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)

15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4

.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10

47
62
62
82
82
82
82
82
82
112

1.19
1.57
1.57
2.08
2.08
2.08
2.08
2.08
2.08
2.84

.509
.624
.810
.993
1.024
1.138
1.265
1.408
1.615
1.967

12.93
15.85
20.57
25.22
26.01
28.91
32.13
35.76
41.02
49.96

156
253
444
581
671
858
1046
1238
1777
2523

232
377
661
865
999
1277
1557
1842
2644
3755

170
320
619
769
919
1218
1518
1817
2715
3764

77
145
281
349
417
552
689
824
1232
1707

Note: Specifications and weights shown are nominal and subject to standard industry tolerances.

1-866-6-NEXANS
12

Pulling Tension

Instrumentation Cable
Electrical Properties
300V Unshielded Pairs/Triads with an Overall Cable Shield
Capacitance
Pairs
Conductor
Conductor
(pf/ft)

Triads

Conductor Size
(AWG)

DC Resistance
(ohms/kft @ 20C)

Conductor
Shield
(pf/ft)

Conductor
Conductor
(pf/ft)

Conductor
Shield
(pf/ft)

20

10.50

48

95

51

102

18

6.64

49

98

52

104

16

4.18

53

107

56

112

300V Shielded Pairs/Triads with an Overall Cable Shield


Capacitance
Pairs
Conductor
Conductor
(pf/ft)

Triads

Conductor Size
(AWG)

DC Resistance
(ohms/kft @ 20C)

Conductor
Shield
(pf/ft)

Conductor
Conductor
(pf/ft)

Conductor
Shield
(pf/ft)

20

10.50

58

115

61

122

18

6.64

61

122

64

125

16

4.18

72

143

76

147

600V Unshielded Pairs/Triads with an Overall Cable Shield


Capacitance
Pairs

Triads

Conductor Size
(AWG)

DC Resistance
(ohms/kft @ 20C)

Conductor
Conductor
(pf/ft)

Conductor
Shield
(pf/ft)

Conductor
Conductor
(pf/ft)

Conductor
Shield
(pf/ft)

18

6.64

39

79

42

103

16

4.18

47

94

50

100

600V Shielded Pairs/Triads with an Overall Cable Shield


Capacitance
Pairs

Triads

Conductor Size
(AWG)

DC Resistance
(ohms/kft @ 20C)

Conductor
Conductor
(pf/ft)

Conductor
Shield
(pf/ft)

Conductor
Conductor
(pf/ft)

Conductor
Shield
(pf/ft)

18

6.64

74

148

78

156

16

4.18

86

172

90

180

1-866-6-NEXANS
13

Instrumentation Cable
Belden Cross-Reference by Part Number
Belden
Part
Number

Nexans
Part
Number

1030A
1031A
1032A
1033A
1034A
1035A
1036A
1037A
1038A
1039A
1040A
1041A
1042A
1043A
1044A
1045A
1046A
1047A
1048A
1049A
1050A
1051A
1052A
1053A
1054A
1055A
1056A
1057A
1058A
1059A
1060A
1061A
1062A
1063A
1064A
1065A
1066A
1067A
1068A
1069A
1070A
1071A
1072A
1073A
1074A
1075A
1076A
1077A

669580
669598
669614
669606
669937
669622
631317
627919
631325
631333
631341
697508
697516
680405
697524
680413
693564
631358
631366
631374
631382
697532
697540
697557
631309
671206
671219
671180
671305
671313
671339
671347
631275
631283
627489
697672
627208
697276
631242
631440
631457
631259
697474
697482
669705
669820
669697

Description

Belden
Part
Number

Nexans
Part
Number

1pr 16AWG OS 300V


1tr 16AWG OS 300V
1pr 18AWG OS 300V
1pr 20AWG OS 300V
1tr 16AWG NS 300V
1pr 16AWG NS 300V
1tr 18AWG OS 300V
3pr16AWG SPOS 600V
50pr18AWG SPOS 600V
4pr 16AWG SPOS 600V
6pr 16AWG SPOS 600V
8pr 16AWG SPOS 600V
12pr 16AWG SPOS 600V
16pr 16AWG SPOS 600V
20pr 16AWG SPOS 600V
24pr 16AWG SPOS 600V
36pr 16AWG SPOS 600V
50pr 16AWG SPOS 600V
2pr 18AWG SPOS 600V
4pr 18AWG SPOS 600V
8pr 18AWG SPOS 600V
12pr 18AWG SPOS 600V
16pr 18AWG SPOS 600V
24pr 18AWG SPOS 600V
36pr 18AWG SPOS 600V
2pr 16AWG SPOS 600V
4pr 20AWG OS 300V
8pr 20AWG OS 300V
12pr 20AWG OS 300V
16pr 20AWG OS 300V
24pr 20AWG OS 300V
36pr 20AWG OS 300V
50pr 20AWG OS 300V
2pr 18AWG OS 600V
4pr 18AWG OS 600V
8pr 18AWG OS 600V
12pr 18AWG OS 600V
16pr 18AWGOS 600V
24pr 18AWG OS 600V
2pr 16AWG OS 600V
4pr 16AWG OS 600V
8pr 16AWG OS 600V
12pr 16AWG OS 600V
16pr 16AWG OS 600V
24pr 16AWG OS 600V
2pr 20AWG SPOS 300V
4pr 20AWG SPOS 300V
8pr 20AWG SPOS 300V

1466A
1467A
1468A
1471A
1472A
1474A
1475A
1476A
1477A
1480A
1481A
1484A
1485A
1486A
1489A
1490A
1492A
1493A
1494A
1495A
1498A
1499A
3025A
3030A
3031A
3032A
3033A
3034A
3035A
3036A
3037A
3038A
3039A
3041 A
3042A
3043A
3044A
3045A
3046A
3047A
3048A
3049A
3050A
3051A
3052A
3053A
3054A
3055A

671123
669633
671115
671107
671099
669671
669689
669721
669713
671412
671420
671198
671164
671172
671297
671131
671222
671230
671248
671255
671446
671453
669739
675256

1-866-6-NEXANS
14

675215
676403
676411
671404

671040
671065
671081
671156

671271
671321
671693
671289
671438

Description

4pr 18AWG OS 300V


8pr 18AWG OS 300V
12pr 18AWG OS 300V
24pr 18AWG OS 300V
36pr 18AWG OS 300V
2pr 18AWG SPOS 300V
4pr 18AWG SPOS 300V
8pr 18AWG SPOS 300V
12pr 18AWG SPOS 300V
24pr 18AWG SPOS 300V
36pr 18AWG SPOS 300V
4pr 16AWG OS 300V
8pr 16AWG OS 300V
12pr 16AWG OS 300V
24pr 16AWG OS 300V
36pr 16AWG OS 300V
2pr 16AWG SPOS 300V
4pr 16AWG SPOS 300V
8pr 16AWG SPOS 300V
12pr 16AWG SPOS 300V
24pr 16AWG SPOS 300V
36pr 16AWG SPOS 300V
2pr 18AWG OS 300V
4tr 18AWG OS 300V
4tr 18AWG STOS 300V
8tr 18AWG OS 300V
8tr 18AWGST OS 300V
16pr 18AWG OS 300V
16pr 18AWG SPOS 300V
16tr 18AWG OS 300V
16tr 18AWG STOS 300V
24tr 18AWG OS 300V
24tr 18AWG STOS 300V
50pr 18AWG OS 300V
50pr 18AWG SPOS 300V
2pr 16AWG OS 300V
2tr 16AWG OS 300V
2tr 16AWG STOS 300V
4tr 16AWG OS 300V
4tr 16AWG STOS 300V
8tr 16AWG OS 300V
8tr 16AWG STOS 300V
16pr 16AWG OS 300V
16pr 16AWG SPOS 300V
16tr 16AWG OS 300V
16tr 16AWG STOS 300V
24tr 16AWG OS 300V
24tr 16AWG STOS 300V

Instrumentation Cable
Belden Cross-Reference by Part Number (continued)
Belden
Part
Number

Nexans
Part
Number

1078A
1079A
1080A
1081A
1082A
1083A
1084A
1085A
1086A
1087A
1088A
1089A
1090A
1091A
1092A
1093A
1094A
1095A
1096A
1097A
1098A
1099A
1100A

671263
671362
671370
671388
671396

627190
631291
627216
631267

631408
631416
697565
631390
627133
627141

Description

12pr 20AWG SPOS 300V


16pr 20AWG SPOS 300V
24pr 20AWG SPOS 300V
36pr 20AWG SPOS 300V
50pr 20AWG SPOS 300V
4tr 20AWG STOS 300V
8tr 20AWG STOS 300V
12tr 20AWG STOS 300V
24tr 20AWG STOS 300V
36pr 18AWG OS 600V
50pr 18AWG OS 600V
36pr 16AWG OS 600V
50pr 16AWG OS 600V
20pr 20AWG SPOS 300V
16tr 20AWG STOS 300V
4tr 18AWG STOS 600V
8tr 18AWG STOS 600V
12tr 18AWG STOS 600V
24tr 18AWG STOS 600V
4tr 16AWG STOS 600V
8tr 16AWG STOS 600V
12tr 16AWG STOS 600V
24tr 16AWG STOS 600V

Belden
Part
Number

Nexans
Part
Number

3056A
3057A
3064A
3066A
3068A
3069A
3080A
3081A
3088A
3089A
3090A
3091A

671149
671487

671054
672063
669226
669085
669101
669119
697391
697888

Description

50pr 16AWG OS 300V


50pr 16AWG SPOS 300V
2tr 18AWG STOS 600V
16tr 18AWG STOS 600V
12tr 18AWG STOS 300V
12tr 16AWG STOS 300V
1pr 14AWG OS 600V
1tr 14AWG OS 600V
1pr 18AWG OS 600V
1tr 18AWG OS 600V
1pr 16AWG OS 600V
1tr 16AWG OS 600V

The cross-reference to Belden part numbers are provided for informational purposes only, and Nexans makes no
representation or warranty, either express or implied, as to the accuracy of any such cross-reference. Belden is not in any way
associated with Nexans. Belden is a registered trademark of Belden Wire & Cable Company.

1-866-6-NEXANS
15

Instrumentation Cable
Belden Cross-Reference by Description
Description

1pr 20AWG
1tr 20AWG
2pr 20AWG
4pr 20AWG
4tr 20AWG
8pr 20AWG
12pr 20AWG
8tr 20AWG
16pr 20AWG
12tr 20AWG
20pr 20AWG
24pr 20AWG
16tr 20AWG
36pr 20AWG
24tr 20AWG
50pr 20AWG
1pr 18AWG
1tr 18AWG
2pr 18AWG
2tr 18AWG
4pr 18AWG
6pr 18AWG
4tr 18AWG
8pr 18AWG
12pr 18AWG
8tr 18AWG
16pr 18AWG
12tr 18AWG
24pr 18AWG
16tr 18AWG
36pr 18AWG
24tr 18AWG
50pr 18AWG

300 Volt - OS
Overall Shield

600 Volt - OS
Overall Shield

Belden
Part
Number

Nexans
Part
Number

1033A
1526A

669606
669747

1056A

671206

1057A
1058A

671219
671180

1059A

671305

1060A

671313

1061A

671339

1062A

671347

1032A
1036A
3025A

669614
669622
669739

3088A
3089A
1063A

669101
669119
631275

1466A

671123
675264
675256
669633
671115
675215
676411

1064A

631283
697490

1065A
1066A

627489
697672

1067A

627208

671107

1068A

697276

671099

1087A

627190

671065

1088A

631291

3030A
1467A
1468A
3032A
3034A
1471A
3036A
1472A
3038A
3041 A

Belden
Part
Number

Nexans
Part
Number

1-866-6-NEXANS
16

300 Volt - SPOS


Shielded Pairs/Triads
Overall Shield

600 Volt - SPOS


Shielded Pairs/Triads
Overall Shield

Belden
Part
Number

Nexans
Part
Number

Belden
Part
Number

Nexans
Part
Number

1075A
1076A
1083A
1077A
1078A
1084A
1079A
1085A
1091A
1080A
1092A
1081A
1086A
1082A

669705
669820

1474A

669671

631358

1475A

669689

1048A
3064A
1049A

3031A
1476A
1477A
3033A
3035A
3068A
1480A
3037A
1481A
3039A
3042A

669697
671263
671362

671370
671388
671396

669721
669713
676403
671404
671504
671412
671420
671040
671081

1093A
1050A
1051A
1094A
1052A
1095A
1053A
3066A
1054A
1096A
1038A

631366
687780
631408
631374
631382
631416
697532
697565
697540
697557
627919

Instrumentation Cable
Belden Cross-Reference by Description (continued)
Description

1pr 16AWGNS
1pr 16AWG
1tr 16AWG NS
1tr 16AWG
2pr 16AWG
3pr 16AWG
2tr 16AWG
4pr 16AWG
6pr 16AWG
4tr 16AWG
8pr 16AWG
12pr 16AWG
8tr 16AWG
16pr 16AWG
12tr 16AWG
20pr 16AWG
24pr 16AWG
16tr 16AWG
36pr 16AWG
24tr 16AWG
50pr 16AWG
1pr 14AWG
1tr 14AWG

300 Volt - OS
Overall Shield

600 Volt - OS
Overall Shield

300 Volt - SPOS


Shielded Pairs/Triads
Overall Shield

600 Volt - SPOS


Shielded Pairs/Triads
Overall Shield

Belden
Part
Number

Nexans
Part
Number

Belden
Part
Number

Nexans
Part
Number

671222

1055A
1037A

631309
631317

671230
669754
671271
671248
671255
671693
671438
672063

1039A
1040A
1097A
1041A
1042A
1098A
1043A
1099A
1044A
1045A

631325
631333
631390
631341
697508
627133
697516
627141

1046A
1100A
1047A

680413

Belden
Part
Number

Nexans
Part
Number

Belden
Part
Number

Nexans
Part
Number

1035A
1030A
1034A
1031A
3043A

669937
669580

3090A

697391

669598
671156

3091A
1069A

697888
631242

1492A

671198

1070A

631440

3045A
1493A

3044A
1484A
3046A
1485A
1486A
3048A
3050A

1489A
3052A
1490A
3054A.
3056A

671164
671172
671321
671289

1071A
1072A

631457
631259

1073A

697474

671297

1074A

697482

671131

1089A

627216

671149

1090A

631267

3080A
3081A

669226
669085

3047A
1494A
1495A
3049A
3051A
3069A
1498A
3053A
1499A
3055A
3057A

671446
671453
671487

697524

The cross-reference to Belden part numbers are provided for informational purposes only, and Nexans makes no
representation or warranty, either express or implied, as to the accuracy of any such cross-reference. Belden is not in any way
associated with Nexans. Belden is a registered trademark of Belden Wire & Cable Company.

1-866-6-NEXANS
17

Instrumentation Cable
Product Data
Test Method

Insulation

Jacket

Temperature Rating

UL 2250 and UL Subject 13

105C

90C

Physicals

Original Elongation

UL 2250 and UL Subject 13

100%

100%

Original Tensile Strength


Air Oven Aging

UL 2250 and UL Subject 13

1500 psi

1500 psi

Elongation (% retention minimum)

UL 2250 and UL Subject 13

70%

70%

Tensile Strength (% retention minimum)

UL 2250 and UL Subject 13

65%

45%

Horizontal

UL 2250 and UL Subject 13

pass

Vertical

UL 2250 and UL Subject 13

pass

Cable Tray (70,000 BTU UL 1685)

UL 2250 and UL Subject 13

Flame

pass
pass

Limiting Oxygen Index

ASTM D 2863

28

27

Cold Bend (temperature 25C)

UL 2250 and UL Subject 13

no cracks

no cracks

Deformation

UL 2250 and UL Subject 13

pass

pass

Insulation Resistance Constant (minimum at 15.6C)

UL 2250 and UL Subject 13

3000

Copper Data
AWG

Stranding

Diameter
inches

AWG

Stranding

mm

Diameter
inches

mm

22

Solid

.0254

.645

22

7 .0100"

.0300

.762

20

Solid

.0320

.813

20

7 .0121"

.0360

.914

19

Solid

.0359

.912

19

7 .0142"

.0430

1.092

18

Solid

.0403

1.024

18

7 .0152"

.0456

1.158

16

Solid

.0508

1.290

16

7 .0192"

.0576

1.463

14

Solid

.0640

1.626

14

7 .0242"

.0726

1.844

12

Solid

.0808

2.052

12

7 .0305"

.0915

2.324

1-866-6-NEXANS
18

WARNING

NOTICE

FLAMMABLE
Non-metallic covering of electrical
cables will burn and under certain
conditions may transmit fire when
ignited.

Nexans has endeavoured to ensure the


accuracy of the data in this publication,
however we cannot be liable for the
consequences of errors or omissions.
All data is subject to change without
notice. The installer and/or user assumes
all liability for the consequences of the
installation and/or use of any of our
products in contravention of any
applicable law, regulation or code.

TOXIC
Burning non-metallic coverings may
emit acid gases, which are highly toxic,
and may generate dense smoke.
CORROSIVE
Emission of acid gases may corrode
metal in the vicinity, such as sensitive
instruments and reinforcing rod in
concrete.

1-866-6-NEXANS
19

S-ar putea să vă placă și