Documente Academic
Documente Profesional
Documente Cultură
CFA Faculty
Advanced Level Telecom Training Centre
de_cfa1_alttc@bsnl.co.in/ 9412739234
About Speaker
Working experience.
2
CSC3300 Configuration
Agenda
CSC3300 Configuration
Configure
Configure
Configure
Data of P-CSCF Data of I-CSCF Data of S-CSCF
Configure Feature Data
End
4
CSC3300 Configuration
MML
C C C C
G S G S
P C P C
F
F
Base bus
CGP distributes
the command to
CSCF through
the Base bus.
CSC3300 Configuration
Hardware Management
Software Management
Service
CSCF
management
Common
information
P-CSCF
I-CSCF
S-CSCF
CSC3300 Configuration
Local domain
Trust domain
Contents
CSCF Data Configuration Overview
CSCF Hardware Data Configuration
CSCF ME & Module Data Configuration
CSC3300 Configuration
Hardware Configuration
Device number
Rack number
Subrack number
Rack 00-19
Filler Panel
Extension
Subrack 01
Extension
Subrack 04
Basic
Subrack 00
Extension
Subrack 03
LAN Switch/
Hard Disk
Array/KVMS/
Filler Panel
CSC3300 Configuration
Extension
Subrack 02
Filler Panel
Hardware Configuration
Subrack number:
In actual deployment, the subrack numbers are
determined by the 8-bit DIP switches on the SDM board.
Switch
Subrack No.
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
on
off
off
off
off
off
off
on
off
off
off
off
off
off
off
on
on
on
on
on
on
on
255
10
on
on
on
CSC3300 Configuration
Hardware Management
11
CSC3300 Configuration
ADD BRD
Example
0
Back panel
card position
Physical
board name
Application
type
Slot No.
12
BASIC SUBRACK 00
Slot No.
9 10 11 12 13
6
O
6
C
6
O
6
C
6
C
CSC3300 Configuration
9 10 11 12 13
Example
Data Configuration:
Step1: Add Rack and Subrack
Select CGP launch the MML command
ADD RACK: RN=0,RNM="IMS",POSNUM=0,ROWNUM=0,
COLNUM=0,MOG="PUBLIC;
ADD SUBRACK: SRN=0,RN=0,PN=1,SBVER=T8280,
SRMUSN1=0, SRMUSN2=2,
SWFBRDT=SWUA0, SWBBRDT=SWIA0,
SRNNM=BASIC SUBRACK",MOG="PUBLIC";
CSC3300 Configuration
Example
Step2: ADD BRD
ADD BRD: SRN=0,SN=10, METYPE=CSCF,
14
CSC3300 Configuration
Function
Type
CSSCU
CSBSU
CSDPU
CSDSU
CSISU
of the CSCF.
CSCDB
15
CSC3300 Configuration
Processes
(modules)
Application
SCU+
CDB+
BSU+ DPU+
IMU
IMU
IMU
CSSCU
BSG + IMU
DPU+SCU+
BSU+CDB+
IMU
CSISU
DPU+
IMU
CSDPU
type
Physical boards
16
CSC3300 Configuration
CSSCU
CSCDB
Module
Application
Type
Physical
Board
UPB0
8BSU+1IMU
UPBA0 11SCU+1IMU
UPBA0
16BSU+1IMU
UPB0
UPB0
4DPU+1IMU
UPBA0
8DPU+1IMU
UPB0
2DPU+4BSU+2CDB+
3SCU+1IMU
UPBA0
2DPU+4BSU+2CDB+
10SCU+1IMU
UPB0
1DPU++1BSU+1CDB
+4SCU+1IMU
UPBA0
1DPU+2BSU+1CDB+
11SCU+1IMU
UPB0
4SCU+1IMU
2CDB+1IMU
CSBSU
CSDPU
UPBA0 2CDB+1IMU
CSDSU
17
Module
CSISU
CSC3300 Configuration
Contents
CSCF Data Configuration Overview
CSCF Hardware Data Configuration
CSCF ME & Module Data Configuration
18
CSC3300 Configuration
The ME and NE
ME (Managed Element) & NE
CGP could manage the following ME:
HSS, CSCF, ATS, CCF ..
19
CSC3300 Configuration
20
CSC3300 Configuration
DPU Module
CDB Module
BSU Module
21
CSC3300 Configuration
Commands Navigation
The following commands will be used when
configuring the CSCF.
ME
CGP
ADD ME
ADD P-CSCF
CSCF
ADD I-CSCF
ADD S-CSCF
ADD MODULE
22
CSC3300 Configuration
Example
Physical board Application
name
type
Front panel card position
Slot No.
6
O
6
C
6
O
6
C
6
C
9 10 11 12 13
CSC3300 Configuration
Example
Data Configuration:
Step1: Add ME
Select CGP launch the MML command
ADD ME: MEID=5,MENAME=ALTTC-CSCF01,
METYPE=CSCF, MEVER="V100R010C00SPC100",
MEVD=XYZ, MELN=LAB;
24
CSC3300 Configuration
Example
Step2: Add NE (P-CSCF, I-CSCF, S-CSCF)
ADD PCSCF: EN=ALTTC-PCSCF01", DN="ims.bsnl.in",
HN=alttc-pcscf01.ims.bsnl.in", LNID=ims.bsnl.in";
ADD ICSCF:EN=ALTTC-ICSCF01", DN="ims.bsnl.in",
HN=alttc-icscf01.ims.bsnl.in;
ADD SCSCF:EN=ALTTC-SCSCF01", DN="ims.bsnl.in",
HN=alttc-scscf01.ims.bsnl.in, IESDN="e164.arpa",
ECPATTERN= EC_COMMON, ENQOR=Y;
25
CSC3300 Configuration
Example
Step3: Add module (SCU, CDB, BSU, DPU)
ADD MODULE: MID=101, MT=SCU, SUBRN1=0,
SN1=10, SUBRN2=0, SN2=12, MNAME=SCU";
ADD MODULE: MID=102, MT=SCU, SUBRN1=0,
SN1=10, SUBRN2=0, SN2=12, MNAME=SCU";
ADD MODULE: MID=103, MT=SCU, SUBRN1=0,
SN1=10, SUBRN2=0, SN2=12, MNAME=SCU";
ADD MODULE: MID=7, MT=DPU, SUBRN1=0,
SN1=10, SUBRN2=0, SN2=12, MNAME="DPU";
26
CSC3300 Configuration
Example
Step3: Add module (SCU, CDB, BSU, DPU)
ADD MODULE: MID=91, MT=CDB, SUBRN1=0,
SN1=10, SUBRN2=0, SN2=12, MNAME="CDB";
ADD MODULE: MID=32, MT=BSU,
SGNLGRP=DNS-1 & DIAM-1 & SIP-1 & COPS-1
& H248-1 & HTTP-1, SUBRN1=0, SN1=10,
SUBRN2=0, SN2=12, MNAME="BSU";
27
CSC3300 Configuration
Contents
28
CSC3300 Configuration
Contents
CSCF Data Configuration Overview
CSCF Hardware Data Configuration
CSCF ME & Module Data Configuration
29
CSC3300 Configuration
Trust Domain
Trust domain
A register or session request from trust domain will
be accepted.
A register or session request from an un-trusted
domain will be rejected.
P-CSCF
Trust
domain A
S-CSCF
Local
domain
P-CSCF
P-CSCF
Untrusted
domain B
31
CSC3300 Configuration
Trust domain
Local domain
32
CSC3300 Configuration
Commands Navigation
Commands for domain configuration
ME
ADD LDMI
CSCF
ADD TDMI
33
CSC3300 Configuration
Example
upw.ims.bsnl.in is the home network and
ims.bsnl.in and ims.rel.in are the visited networks.
P-CSCF
Trust Domain:
ims.bsnl.in
10.191.0.0
255.255.0.0
I/S-CSCF
Local Domain:
upw.ims.bsnl.in
10.191.0.0
255.255.0.0
Local Office
34
Page34
IP backbone
P-CSCF
Untrust domain:
ims.rel.in
192.1.0.0
Example
Data configuration:
Local domain(LDMI)
ADD LDMI: ADDRT=DOMAINNAME,
DN=upw.ims.bsnl.in";
ADD LDMI: ADDRT=IPADDRESS,
IPSEG=10.191.0.0", MASK="255.255.0.0";
(ADDRT is mandatory).
35
CSC3300 Configuration
Example
Data configuration:
36
CSC3300 Configuration
Contents
CSCF Data Configuration Overview
CSCF Hardware Data Configuration
CSCF ME & Module Data Configuration
37
CSC3300 Configuration
Contents
38
CSC3300 Configuration
10.191.0.0
255.255.0.0
168.17.3.0
AC
SBC
GGSN
WLAN
xDSL/LAN
UMTS/GPRS
192.168.0.0
39
191.1.2.0
CSC3300 Configuration
Example
Add P-CSCF access network:
ADD PACN: ANN=ALTTC,
ADDRNAME=pcscf-access01,
ANDN=upw.ims.bsnl.in,
ANT=LAN, IPT=IPV4,
UEIP=10.191.0.0,
UEMASK=255.255.0.0;
40
CSC3300 Configuration
Contents
41
CSC3300 Configuration
S-CSCF Assignment
When a subscriber initiates a SIP REGISTER request, the
I-CSCF must allocate an S-CSCF for the subscriber, that is,
select the S-CSCF .
Capability set is used by ICSCF to select an S-CSCF.
S-CSCF1
Capability: 3, 4, 5
P-CSCF
service
name
42
capability
ID
emergency
call
SIP
extending
function 1
Page42
I-CSCF
S-CSCF2
Capability: 1, 2, 3, 4, 5
S-CSCF3
Capability: 1, 2, 3
Example
SURI="sip:alttc-scscf01.ims.bsnl.in,
CAPNUM=CAPNUM0;
43
CSC3300 Configuration
Contents
44
CSC3300 Configuration
TARGET= alttc-icscf01.ims.bsnl.in";
45
CSC3300 Configuration
IPT=IPV4, ADDR="10.191.255.5";
ADD DNSRESA: NAME= alttc-icscf01.ims.bsnl.in",
IPT=IPV4, ADDR="10.191.255.6";
ADD DNSRESA: NAME= alttc-scscf01.ims.bsnl.in",
IPT=IPV4, ADDR="10.191.255.7";
46
CSC3300 Configuration
47
Page47
Contents
48
CSC3300 Configuration
Interworking with CS
The IMS network interworks with the CS domain through
the BGCF and the MGCF.
BGCF: selects the entry to the CS domain.
MGCF: All call control signaling messages from CS
subscribers are destined to the MGCF.
The MGCF is responsible for protocol translation between
the ISUP or BICC protocol and the SIP protocol, and
transfers the session to the IMS.
DNS/ENUM:
ENUM: Tel URI ----> SIP URI
DNS: SIP URI ----> IP address
49
CSC3300 Configuration
Command Explanation
Data configuration
MGCF01
IP: 10.10.1.6
PCSCF01
SCSCF01
ADD SRTADDR
ADD SRTANA
ADD SNRTANA
UE1
51
Page51
MGCF02
IP: 180.1.200.5
Example
Add Number Analysis:
ADD SRTADDR: RTAN=MGCF02, ENTITYPE=MGCF,
ADDRTYPE=IPV4, IPADDR="180.1.200.5";
ADD SRTANA: RTSN=PFX_2847, RTSSN=ALL,
RTSAN=ALL, RTAN=MGCF02;
ADD SNRTANA:
NRTANATYPE=GLOBAL_NUMBER_PREFIX,
NRTANACONT=K911202847, RTSN=PFX_2847;
53
CSC3300 Configuration
Summary
We have learn about the
CSCF Data Configuration Overview
CSC3300 Configuration
THANK YOU!
CFA Faculty
Advanced Level Telecom Training Centre
de_cfa1_alttc@bsnl.co.in/ 9412739234