installation types
Uplink to transport network
outdoor cabinets
Fanless operation possible
Provision, configuration and
Overview
Hybrid architecture
Safety/redundancy
MPLS-TP
With MPLS-TP, the XMC20 provides data paths also in Ethernetbased transport networks which
guarantee deterministic transmission behaviour. By this, the
XMC20 achieves highest availability also in Ethernet transport networks known from SDH
technology
Technical Data
General
Number of slots (for line cards)
Slots for core units with redundancy
Slots for media gateways with redundancy
Supported fan unit
Capacity features
Capacity Ethernet star per slot
SDH capacity
Dimensions (W x D x H) and weights
Required height units
With front cover and cable stacking
Cable stacking
Heat sink
Construction type and design
Standards
Electromagnetic tolerance
Safety
Management
ECST
UNEM
Power supply
Input voltage nominal (min/max)
Operational environment
Operation temperature range
Humidity
XMC25
XMC23
up to 20
up to 7
Max. 2
Max. 2
Max. 2
Max. 2
COOL4
COOL6
XMC25
XMC23
2 x 10GbE + 2 x 1GbE
up to STM-16
XMC25
XMC23
8 HE
4HE
(with cabling)
482,6 x 306 x
482,6 x 306 x 176,1mm,
309,5mm, 7.690g
5.340g
482,6 x 240 x
contained in
87,1mm, 870g
19 adapter
482,6 x 237 x
Not required
87,8mm, 1.580g
19- und ETSI assembly
XMC22
up to 3
Max. 1 (no redundancy)
Max. 2
COOL8
XMC22
1GbE
XMC22
2,2HE
482,6 x 306 x 95mm,
3.600g
contained in
19 adapter
Not required
EN 55022, Klasse B
IEC/EN 60950-1
For local management
For central network management
48/60VDC (39,5VDC 72VDC)
25C +60C
In accordance with class 3.2, up to 95 %, without condensation
KEYMILE 2015-08-06 V002. Our products are subject to continuous development and we reserve the right to amend specifications without notice. Some functionality is subject to a feature license.
Fanless operation