Documente Academic
Documente Profesional
Documente Cultură
RELIABILITY
REDEFINED . . .
www.facebook.com/daikinindia
www.twitter.com/daikinindia
PFS - B/2014
12th Floor, Building No. 9, Tower A, DLF Cyber City, DLF Phase III, Gurgaon - 122 002, Haryana, India.
Tel.: 0124-4555444, Fax.: 0124-4555333. Corporate Identification Number (CIN) - U74899DL2000PTC104990
Registered Office: F-25/2, Okhla Industrial Area, Phase II, New Delhi - 110 020, e-mail: ho@daikinindia.com
Visit us at www.daikinindia.com
www.daikinindiablog.com
* The specifications, designs, and information in this brochure are subject to change without notice.
A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration
Chiller Features
Long lifetime
Why Daikin
Combination of Daikins philosophy of Quality and Advanced Screw Technology
Lower noise
PFS-B series chillers utilizes colourful touch screen with user friendly design for convenient operation and maintenance.
Operators can view all running status and parameters, change set points and clear alarms, as well as maintain data logging
on PC.
Following indicator lights and switches are equipped on
the control panel:
Emergency stop switch
Unit/ Compressor switch (compressor switch only on
2 compressor model)
Power / running / alarm indicator lights
Compressor running lights
Control display, Alarm and protection function:
Display:
Touch screen display chiller operation data and alarm intimation, easy operation and maintenance.
Controller output Star Delta conversion time results in a more stable startup without extra electric maintenance.
Cooling water / chilled water pump automatically ON/OFF, water pump will be pre-startup before chiller startup and
stop after chiller shutoff.
Cooling tower fan automatically ON/OFF, Controller analyzes chillers operation load % and ELWT, select ON/OFF
logic, send ON/OFF signal, to make system always runs in energy saving condition.
Multi-compressor lead-lag balance control, before chiller startup, control will analyze each compressors total working
hours, automatically select startup compressor which runs less working hours and stop compressor which runs longer
working hours. In this way, every compressors working hours can be balanced.
Stabilized PID (Proportional Integral Derivative) regulation by microprocessor via analyzing the signal sensed by the
evaporator leaving water sensor with an accuracy of +/- 0.1 deg C.
Physical Data
Unit PFS-DBRY
1001
1101
1201
1351
1401
1501
1601
Cooling capacity
TR
98.1
106.3
118.1
128.9
134.0
144.9
155.1
Alarm information
No. of compressors
No.
Refrigeration circuits
No.
Unit length
mm
3340
3340
3340
3340
3340
3340
3340
Unit width
mm
1485
1485
1485
1485
1485
1485
1485
History trend
Unit height
mm
1956
1956
1956
1956
1956
1956
1956
kg
3136
3298
3172
3347
3284
3484
3319
kg
3390
3552
3442
3617
3572
3772
3615
Unit PFS-DBRY
1701
1801
1901
2001
2151
2301
2451
186.2
194.8
207.3
221.3
237.4
Cooling capacity
TR
166.8
174.9
No. of compressors
No.
Refrigeration circuits
No.
Unit length
mm
3340
3468
3468
3468
3468
3468
3468
Unit width
mm
1485
1676
1676
1676
1676
1676
1676
Unit height
mm
1956
2185
2185
2185
2185
2185
2185
kg
3522
4712
5030
4787
5078
4816
5117
RS485 building communication to communicate directly with 3rd party control system via public protocol. It then can
realize quick and precise data transfer.
kg
3818
5135
5453
5210
5501
5255
5556
Pre-calibration and pre-alarm protection to avoid sudden shut off result from sharply unload / load.
Built in Time Clock, 7 working days automatically startup/stop setting. It can then achieve annual non-human-operation
function.
Notes
Physical Data
Unit PFS-DBRY
2551
2652
2701
2802
3002
3051
Cooling capacity
TR
250.1
257.8
266.1
273.9
289.9
300.7
No. of compressors
No.
Refrigeration circuits
No.
Unit length
mm
3470
3468
3770
3770
3770
3470
Unit width
mm
1780
1676
1780
1676
1676
1780
Unit height
mm
2337
2235
2337
2235
2235
2337
kg
5442
5462
5876
5732
5769
5520
kg
5972
5914
6406
6209
6260
6070
3252
3301
3502
4302
4602
4902
Unit PFS-DBRY
Cooling capacity
TR
312.8
320.4
337.4
418.5
449.3
480.3
No. of compressors
No.
Refrigeration circuits
No.
Unit length
mm
3770
3770
3770
4314
4314
4314
Unit width
mm
1676
1780
1676
1908
1908
1908
Unit height
mm
2235
2337
2235
2152
2152
2152
kg
5793
5963
5848
8747
8747
8880
kg
6293
6513
6360
9411
9411
9583
Notes:
1. Nominal cooling capacity is based on AHRI conditions 6.7C leaving evaporator water temperature; 29,4C entering
condenser water temperature.
2. Within the scope of AHRI certification program, ratings are certified in accordance with AHRI 550/590.All other
ratings are in accordance with ARI 550/590.
3. Power supply: 415V/3Ph/50Hz, Voltage tolerance: 10%.
4. The dimensions given are for chiller with Wye-Delta starter..