Sunteți pe pagina 1din 2

P R O D U C T D ATA

Drillers Cabin
AXON drillers cabins provide a safe and efficient working environment for drilling, intervention, and process
controls. These self-supporting structures feature an optimized design that is focused on reducing human stress
and noise, while providing maximum line-of-sight for the operators from inside the cabin. Additional space is
also available for personnel supporting the operation crew, providing for a common collaboration environment.

FEATURES / BENEFITS
Certifications
n

Cabin exterior rated for ClD2 (Zone 2) service

Applicable equipment in the drillers cabin is rated for ClD2 (Zone 2) service

Fabricated with stainless steel exterior and insulated to an R19 level on all faces

Cabin interior is lined with A60 fire resistant material; doors are also A60 rated

Self-supporting structure includes noise and vibration considerations/restrictions

Two exits consisting of full-sized man-doors, gaskets, and self-closers to meet regulations for gas tight seal

Design
n

Doors fitted with keyed, lockable hardware for secure locking during transit and storage

Tinted safety glass windows with protection grids and exterior protection bars

Equipped with a Type Z purge from the HVAC unit

Gas detection and auto closing dampers provided at HVAC inlet (dampers close upon gas detection at inlet)

Available provisions for automatic shutdown of unrated equipment in the cabin upon internal gas detection

Wiper/flusher system with integrated controls included

Equipped with integrated PA, Drillers Talkback, Telecom and UHF

Typical installation includes an operator station designed for ease of maintenance access

8909 Jackrabbit Road Houston, Texas 77095 P 281.855.3200

axonep.com

Drillers Cabin
SPECIFICATIONS
Dimensional Data
1

3
TOP VIEW

101.68

118.62
43.97
152.80
A

159.18
C
DRAWN BY
CHECKED BY
ENGINEERED BY
APPROVED BY
CLIENT APPROVAL

ESTIMATED WEIGHT:
SE PROPRIETARY
HIS DOCUMENT IS
EIN WILL NOT BE
RITING BY AXON RIG NEXT ASSY.:

NTAL TO OR IN
HIS DOCUMENT,
SUPPLIER DWG. NO.:
ED INFORMATION
ES, OR ON DEMAND.

MMA

MMA

JSA

JSA

129.80

7095

DRAWWORKS VIEW

NCEPT
ESIGN

002501-101

48.70

V-DOOR VIEW
PROJECT:

DRILL FLOOR VIEW

118.62

TITLE:

BassDrill

FABRICATION LAYOUT AND


ELEVATION DETAILS
DRILLERS CABIN
[311-BX-002]

SHT. SIZE

SCALE

N.T.S

DRAWING NUMBER

0826-311-DWG-6000
SFI CODE:

SHEET 2 OF 5

REV.

42.44

44.87

Additional Images
9
8
7
6
5
4
3
2
1
No.

DRAWING No.

REV.

DESCRIPTION

REFERENCE DRAWINGS
1

E
D
C
B
A

12/09/2013

REV

DATE.

11/26/2013
9/20/2013
6/12/2013
6/3/2013

MMA
MMA
MMA
MMA
MMA

MMA
MMA
MMA
MMA
MMA

JSA
JSA
JSA
JSA
JSA

LAYOUT UPDATE - DSIC REVIEW NOTES


LAYOUT UPDATE - AS PER DSIC NOTES TRANSMITTAL
LAYOUT UPDATED
INCLUDING OFE DETAILS
ISSUED FOR APPROVAL

REV. BY APPVD. APPVD.

REVISIONS

DESCRIPTION

RIG CONCEPT
AND DESIGN
8909 JACKRABBIT ROAD, HOUSTON, TX 77095

NOTICE OF CONFIDENTIALITY

DRAWN BY
CHECKED BY
ENGINEERED BY
APPROVED BY
CLIENT APPROVAL

MMA

MMA

JSA

JSA

ESTIMATED WEIGHT:
THIS DOCUMENT AND THE INFORMATION CONTAINED WITHIN COMPRISE PROPRIETARY
INFORMATION OWNED SOLELY BY AXON RIG CONCEPT AND DESIGN. THIS DOCUMENT IS
PROVIDED SUBJECT TO THE PROVISION THAT THE INFORMATION HEREIN WILL NOT BE
DISCLOSED OR REPRODUCED UNLESS SPECIFICALLY AUTHORIZED IN WRITING BY AXON RIG NEXT ASSY.:
CONCEPT AND DESIGN. NOR WILL IT BE USED IN ANY WAY DETRIMENTAL TO OR IN
COMPETITION WITH INTEREST OF AXON RIG CONCEPT AND DESIGN. THIS DOCUMENT,
SUPPLIER DWG. NO.:
REPRODUCTIONS PREVIOUSLY AUTHORIZED IN WRITING, AND ASSOCIATED INFORMATION
SHALL BE RETURNED WHEN THEY HAVE SERVED THEIR INTENDED PURPOSES, OR ON DEMAND.

8909 Jackrabbit Road Houston, Texas 77095 P 281.855.3200

002501-101

axonep.com

S-ar putea să vă placă și