Sunteți pe pagina 1din 6

Please comply the following items marked with tick under the MUST COMPLY

column accordingly:

N
O

ROAD

A1

Design calculation for the pavement thickness should


be submitted
Bitumen road shall be designed using road Note 29 or
31 base on the necessary Standard Axles. CBR value
for subgrade can vary according to soil condition and
minimum of 10% while CBR value for sub-base and
road base must be minimum 30% and 80% respectively
and to be stated on plan.
Road base/ sub-base/ premix thickness should comform
to the designed thickness.
Minimum width for road carriageway should be:
A. 6.1m (20 feet) for 12.2m (40ft) road reserve
B. 6.7m (22 feet) for 15.2m (50ft)road reserve
C. 7.3m (24 feet) for 20m (66ft) road reserve
All turning radius must not be less than 6.1m (20ft) for
secondary road, 9.1m (30ft) for primary road and
15.2m (50ft) for major trunk road.
The whole road surface for commercial area must be
sealed except the public utility reserve/space (eg.
Walkway, pedestrian mall etc.)
The road surface camber should not be less than 1:33
(3%)
Road shoulder must be covered with close turfing to
prevent soil erosion
Road kerb must be constructed at both sides of the
road
All precast kerb must be Grade 20 (1:2:4 mixed)
concrete and not more than 915mm (3 feet length)
The kerb must be placed on 100mm (4) thick Grade
20(1:2:4 mixed) concrete base and the joint sealed with
1:3 cement mortar.
The height of kerb measuring from the finished road
surface should be at least 200mm (8) for shop &
industrial and 150mm (6) for residential development.
Road surface water to be discharged through the kerb
via 150mm dia.upvc pipe spaced at 3m from centre to
centre
All traffic sign board and road marking must comply to

A2

A3
A4

A5

A6

A7
A8
A9
A1
0
A1
1
A1
2
A1
3
A1

Compli
ed N.A

MUST
COMPL
Y

4
A1
5
A1
6
A1
7

JKR standard
To obtain letter of approval from JKR on the design of
the entrance and/or exit from this development onto
the major JKR trunk road
Cross-section details for various roads to be submitted
Details of the proposed Road Name signboard and their
proposed locations to be submitted

N
O

DRAIN

B1

Design calculation to justify the sizes of the drains to be


submitted
Structural calculations for the various types of drain
and culvert to be submitted
While works is going on, developer must ensure no
blockage to existing drain/ water course by regular
maintenance to ensure good and smooth flow of water
at all time
Concrete must have a minimum thickness of 100mm
(4) and reinforced with BRC or high tensile bars
Lean concrete of Grade 15 (1:3:6 mix) to be laid below
the drain as base [minimum thickness= 50mm (2)]
Rubbish trap to be installed at the lower end of the
drain before entering the drain sump or culvert. Details
to be submitted for checking
Heavy duty m.s. grating to be installed at all the drain
sumps for safety purpose especially next to the
pedestrian walkway
All pre-cast drain slab/ concrete blocks to be jointed
using cement mortar in good condition to prevent
leakage
All iron grille drain covers must have hinges with m.s.
frame permanently fixed to the concrete. Details to be
submitted
All culverts must have a minimum internal diameter of
600mm (24 inches)
Culvert base shall be constructed using Grade 20 (1:2:4
mixed) concrete reinforced with BRC A8 or HT steel bar
To protect both ends of the culvert with concrete wing
walls rising at least 150mm (6) from the ground
surface
To obtain letter of approval from JPS on the MSMA
Design for the drainage system
All concrete driveway leading to buildings must be
provided with removable iron grille cover of minimum
610mm x 760mm (2 x 26) at 1.52m (50) intervals
above the drain for easy maintenance in future
All culvert must be provided with opening of min.
610mm x 760mm (2 x 36) covered with heavy duty
iron grille constructed with hinges of m.s. frame
permanently fixed to concrete directly above the

B2
B3

B4
B5
B6

B7

B8

B9

B1
0
B1
1
B1
2
B1
3
B1
4

B1
5

Compli
ed N.A

MUST
COMPL
Y

B1
6
B1
7

B1
8

culvert for easy future maintenance


All drains exceeding 380mm (13) depth must be
designed to allow for r.c.struts to protect the drain
Drain covers for shoplots must be designed for 2.44m
(8) cast-in-situ r.c. concrete slab with 1.8m (6)
opening covered with removable r.c. drains covers or
heavy duty iron grille constructed with hinges of m.s
frame permanently fixed to concrete at both ends of
drain for easy maintenance in future
The minimum gradient of r.c concrete drain should be
1:400 (0.25%)

Please comply the following items marked with tick under the MUST COMPLY
column accordingly:

N
O
A1
A2

N
O
B1
B2
B3
B4
B5

N
O
C1

GENERAL (To be stated on plan)

Complied
/N.A.

Minimum depth of back-fill above sewer pipe


should be 760mm (26)
All sewer pipe to be located below water pipe in
the road reserve

DESIGN

Complied
/N.A.

Daily Design Flow, Population Equivalent etc. to


be designed to MS 1228 standard
Minimum sewer pipe size to be 150mm (6)
diameter
1: 100 minimum slope at the upper most stream
be provided to facilitate smooth sewer flow
Minimum self-cleansing velocity at full flow
condition to be 0.8m/s (2.6 ft./s)
Velocity of flow at half or full bore to be not
greater than 4.0m/sec (13 ft./s)

LAYOUT
The Sewer pipe should be manufactured by
material approved by SIRIM and Jabatan
Pembetungan Negara (eg. Upvc etc)

MUST
COMPLY

MUST
COMPLY

Complied
/N.A.

MUST
COMPLY

C2
C3

Different sizes of pipe to be coloured or indicated


differently on the plan
No bending of sewer pipe is allowed

N
O

LONGITUDINAL SECTION

D1

The distance between 2 manholes must not be


more than 30m (100ft)
The existing ground level, proposed ground/ invert
level, distance and gradient to be indicated on
plan
The discrepancy in level for MH______ in
section________
And section_______ to be clarified
To indicate the distance and level in meters or
feet
The missing longitudinal section from MH______ to
MH______ to be submitted

D2

D3

D4
D5

N
O

DETAILS

E1

All sewer pipe under road carriageway must be


encasted in 150mm (6) thick concrete reinforced
with BRC A7
For brick manhole less than 760mm (26) depth,
the minimum wall thickness shall be 100mm (4)
For manhole with depth between 760mm (26)
and 1220mm (40), the minimum brick wall
thickness shall be 225mm (9)
All manhole over 1220mm (40) depth must be
constructed using 150mm (6) thick Grade 25
concrete reinforce with BRC A8
For manhole exceeding 1.2m (40) depth, its
diameter must be 1830mm (60)for the whole
depth
C1 steps must be provided for manhole exceeding
760mm (26)
For manhole less than 1220mm (40) depth, its
diameter must be 1220mm (40) for the whole
depth
The maximum depth of manhole must not exceed
4.5m (15 ft.)
Heavy duty manhole cover should be used in road
carriageway and light medium duty for other area

E2
E3

E4

E5

E6
E7

E8
E9

Complied
/N.A.

MUST
COMPLY

Complied
/N.A.

MUST
COMPLY

E1
0
E1
1
E1
2

All manholes (outside the building boundary)


should be constructed with r.c. round manhole
with hinges and M.P.S. logo.
Details of round manholes with hinges and logo to
be submitted.
Details and capacity calculations for the sewerage
treatment plant to be submitted