Sunteți pe pagina 1din 4

DEAD LOAD CALCULATION FOR RCC T-GIRDER DECK :

Note : All figures in red coloured font are to be treated as input data. All dimensions are in metres.

Load from Superstructure :

Depth of Super Structure =


No. of longitudinal girders =

2.65

2.65

2.7
4

2.65

0.200
150

2.075

300
0.325
150

150

TYPICAL CROSS SECTION OF T-BEAM DECK

0.625

Cross Sectional Area :-(Intermediate Section )


i)
Intermediate Slab
(2.65-0.325)*3*0.25

1.744

m2

ii)

Cantilever Slab

1.014

m2

iii)

300 X 150 haunch

0.135

m2

iv)

Web

(2.7-0.4)*0.325*4

2.990

m2

v)

Bottom Bulb

(0.625*0.25+0.5*(0.325+0.625)*0.15)*4

0.910

m2

Total

6.792

m2

0.5*(0.2+0.33)*(2.075-0.325/2)*2
(0.5*0.3*0.15)*6

SUM(1.74375:0.91)

EFFCT OF END THICKENING OF GIRDER


0.90

280
3.24t/m

0.90

300

Load intensity at B in addition to 325th


(0.625-0.325)*2.125*2.4*4

6.12 t/m

250
150
2.125

300
1900

150
250

DEAD LOAD INTERMEDIATE DIAPHRAGM


Thickness of diaphragm

Thickness of Diaphragm =

0.325 m

0.325m

Cross Sectional area in elevation

(2.65-0.325)*(2.7-250*0.001-250*0.001)-0.15*0.3-0.15*0.15

5.048 m2

Total Load of each diaphragm


(Intermediate)

5.0475*0.325*2.4*3

11.81 T

Cross sectional area in elevation

(2.65-0.625)*(2.7-250*0.001-250*0.001)-0.15*0.075

4.444 m2

Total load of end diaphragm(2 nos thus)

(4.44375*0.325*2.4*3*)2

D.L. Running meter

6.79*2.4

DEAD LOAD OF END DIAPHRAGM

20.797 T
16.30 t/m
(Ref P-6)

S.I.D.L.
I)Wearing coat

=0.2t/m2

ii)Crash barrier

=0.2x11.1

2.22

=1.0x2
Total

S.I.D.L reaction

4.22*(26.71-2*0.02)*0.5
10.4

T
6.12

11.81

2.00
4.22
56.3 T

10.4 T

t/m
16.30 t/m

0.02

0.28

26.15
26.71

A
RA = 16.3*(26.71-0.02*2)*0.5+6.12*0.9+0.5*6.12*0.9+10.4+11.81*0.5

241.9 T

Total dead load reaction

241.93+56.27

For design of substructure increasing by 5%

298.20 T
1.05*298.2

313.11 T
Say=

Total Dead Load on Pier due to Super structure

314 T
628 T