SoftSwitch Control Equipment

PC Server Telnet Configuration


Version 2.0.1.07

ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn

LEGAL INFORMATION
Copyright 2010 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of
this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION
or of their respective owners.
This document is provided as is, and all express, implied, or statutory warranties, representations or conditions are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the
information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject
matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee,
the user of this document shall not acquire any license to the subject matter herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History
Revision No.

Revision Date

Revision Reason

R1.0

201007-15

First edition

Serial Number: SJ-20100630164932-055

Contents

About This Manual............................................. I


Declaration of RoHS Compliance ....................... I
PC Server Telnet Configurations ........................1
Configuring the background Interface................................ 1
Configuring the Foreground Interface ................................ 2
Configuring clit.out ......................................................... 5
Testing Telnet................................................................. 6

Figures ..............................................................9

Confidential and Proprietary Information of ZTE CORPORATION

ZXSS10 SS1b PC Server Telnet Configuration

This page is intentionally blank.

II

Confidential and Proprietary Information of ZTE CORPORATION

About This Manual


Purpose

At first, thank you for choosing ZXSS10 SS1b of ZTE Corporation!


ZXSS10 SS1b is fully compatible with the layered standard NGN
model. It can provide NGN with service call and connection control functions which are required by real-time services. By using
ZXSS10 SS1b, operators can provide users with many kinds of
multimedia services which involve voice, video and data. ZXSS10
SS1b is, therefore, the core of NGN in terms of call and control.
This manual introduces the PC Server Telnet configurations of
ZXSS10 SS1b.

Intended
Audience

Prerequisite Skill
and Knowledge
What Is in This
Manual

Conventions

This document is intended for:

Technical managers

Network planning engineers

Equipment installation engineers

Maintenance engineers

To use this document effectively, users should have a general understanding of SoftSwitch system.
This manual contains the following chapter:
Chapter

Summary

Chapter
1,
PC
Server Telnet Configurations

It introduces the PC Server Telnet configurations

ZTE documents employ the following typographical conventions.


Typeface

Meaning

Italics

References to other Manuals and documents.

Quotes

Links on screens.

Bold

Menus, menu options, function names, input fields,


radio button names, check boxes, drop-down lists,
dialog box names, window names.

CAPS

Keys on the keyboard and buttons on screens and


company name.
Note: Provides additional information about a certain
topic.
Checkpoint: Indicates that a particular step needs to
be checked before proceeding further.
Tip: Indicates a suggestion or hint to make things
easier or more productive for the reader.

Confidential and Proprietary Information of ZTE CORPORATION

ZXSS10 SS1b PC Server Telnet Configuration

Mouse operation conventions are listed as follows:

II

Typeface

Meaning

Click

Refers to clicking the primary mouse button (usually the


left mouse button) once.

Doubleclick

Refers to quickly clicking the primary mouse button


(usually the left mouse button) twice.

Right-click

Refers to clicking the secondary mouse button (usually


the right mouse button) once.

Confidential and Proprietary Information of ZTE CORPORATION

Declaration of RoHS
Compliance
To minimize the environmental impact and take more responsibility to the earth we live, this document shall serve as formal declaration that ZXSS10 SS1b manufactured by ZTE CORPORATION
are in compliance with the Directive 2002/95/EC of the European
Parliament - RoHS (Restriction of Hazardous Substances) with respect to the following substances:

Lead (Pb)

Mercury (Hg)

Cadmium (Cd)

Hexavalent Chromium (Cr (VI))

PolyBrominated Biphenyls (PBBs)

PolyBrominated Diphenyl Ethers (PBDEs)

The ZXSS10 SS1b manufactured by ZTE CORPORATION meet


the requirements of EU 2002/95/EC; however, some assemblies
are customized to client specifications. Addition of specialized,
customer-specified materials or processes which do not meet the
requirements of EU 2002/95/EC may negate RoHS compliance of the
assembly. To guarantee compliance of the assembly, the need for
compliant product must be communicated to ZTE CORPORATION in
written form. This declaration is issued based on our current level
of knowledge. Since conditions of use are outside our control, ZTE
CORPORATION makes no warranties, express or implied, and assumes
no liability in connection with the use of this information.

Confidential and Proprietary Information of ZTE CORPORATION

ZXSS10 SS1b PC Server Telnet Configuration

This page is intentionally blank.

II

Confidential and Proprietary Information of ZTE CORPORATION

Chapter

PC Server Telnet
Configurations
Table of Contents
Configuring the background Interface....................................
Configuring the Foreground Interface ....................................
Configuring clit.out .............................................................
Testing Telnet.....................................................................

1
2
5
6

Configuring the background


Interface
Prerequisites

You have the related software and files.

You have the rights to execute commands as a root user in PC


Server.

Context

This topic describes how to configure the 6000 interface in PC


Server.

Steps

1. Upload clittelnet to the directory /etc/xinetd.d/ of PC Server.


Remember to use a binary mode.
2. Modify the file /etc/services:
Add the following two lines and save them
clittelnet
clittelnet

6000/tcp
6000/udp

# Telnet 6000
# Telnet 6000

after these two lines


telnet
Telnet telnet

23/tcp

#
23/udp

# Telnet

3. Execute /etc/init.d/xinetd restart as a root user to restart the


network service:
ssdatabase:~ # /etc/init.d/xinetd restart
Shutting down xinetd:
Starting INET services. (xinetd)

done
done

4. Test whether the 6000 interface can be used or not in the SUSE
system of PC Server.
telnet 127.0.0.1 6000

END OF STEPS

Confidential and Proprietary Information of ZTE CORPORATION

ZXSS10 SS1b PC Server Telnet Configuration

Configuring the Foreground


Interface
Prerequisites

Context

Steps

You have entered the Data Configure interface.

You have the rights to configure the port distribution and the
port visit list.

This topic describes how to configure the Telnet 6000 interface (set
its interface module to be 512) on the network management interface in order to Telnet to the background by using the foreground
IP address and 6000 interface.
1. Add a 6000 interface in Port Distribution.
i.

In the Data Configure interface, select Global > IT Configuration > Port Distribution. The Port Distribution
interface appears, as shown in Figure 1.
FIGURE 1 PORT DISTRIBUTION

ii. Click Add in the Port Distribution interface. The Add


Port Distribution interface appears, as shown in Figure
2.

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 1 PC Server Telnet Configurations

FIGURE 2 ADD PORT DISTRIBUTION

iii. Configure the 6000 interface in the Add Port Distribution


interface. Remember to configure the number of the processing board which corresponds to the 6000 interface to
be 512, as shown in Figure 3.
FIGURE 3 CONFIGURING 6000 INTERFACE

iv. After finishing the configurations, click OK.


2. Add 6000 interface in Port Visit Control List Configuration.
i.

In the Data Configure interface, select Global > IT Configuration > Port Visit Control List Configuration. The
Port Visit Control List Configuration appears, as shown
in Figure 4.

Confidential and Proprietary Information of ZTE CORPORATION

ZXSS10 SS1b PC Server Telnet Configuration

FIGURE 4 PORT VISIT CONTROL LIST CONFIGURATION

ii. Click Add in the Port Visit Control List Configuration


interface. The Add Port Visit Control List Configuration
interface appears, as shown in Figure 5.
FIGURE 5 ADD PORT VISIT CONTROL LIST CONFIGURATION

iii. Configure the visit list of 6000 interface in the Add Port
Visit Control List Configuration interface. For protocols,
select 2-TCP, as shown in Figure 6.
FIGURE 6 CONFIGURING

THE

VISIT LIST

Confidential and Proprietary Information of ZTE CORPORATION

OF

6000 INTERFACE

Chapter 1 PC Server Telnet Configurations

iv. After finishing the configurations click OK.


END OF STEPS

Configuring clit.out
Prerequisites

You have the related software and files.

You have the rights to execute commands as a root user in PC


Server.

You have the rights to execute the 2496 command.

Context

This topic describes how to configure clit.out so as to start the


system after logging in to the system through Telnet.

Steps

1. Copy all the files in the directory /DBServer/sun_oracle8/clit/ in the asc mode to a temporary directory folder
of the background server.
2. Assign executable rights to tel.sh in this directory:
chmod 755 tel.sh

3. Execute tel.sh in the directory and set a user name and a password (Here we assume that the directory is named as /zhao
and both the user name and the password are telnet):
ssdatabase:/zhao # ./tel.sh
Welcome to install telnet program for CLIS of SS .
Copyright : 2001 - 2002 ZTE Corp .
installing ...
mkdir: cannot create directory `clit': File exists
mkdir: cannot create directory `sshelp_ch': File exists
mkdir: cannot create directory `sshelp_en': File exists
mkdir: cannot create directory `txt': File exists
mkdir: cannot create directory `txt': File exists
groupdel: GID `45678' is primary group of `telnet'.
groupdel: Cannot remove user's primary group.
groupadd: GID 45678 is not unique.
no crontab for telnet
Please input the password of user telnet >>>
Changing password for telnet.
New Password:
Enter telnet
Bad password: too simple
Reenter New Password:
Enter telnet
Password changed.
./tel.sh: line 48: help: no help topics match folder'.
Try help help' or man -k folder' or info folder'.
Installation is over .

4. Copy clit.out in the directory PCServer/ to the directory


/home/zxss10/clit/ of the background. Remember to use a
binary mode.
5. If English prompts are needed, create /home/zxss10/config/clit_LANG.ini whose contents are
LANG=0

Confidential and Proprietary Information of ZTE CORPORATION

ZXSS10 SS1b PC Server Telnet Configuration

Note:
LANG=1 means Chinese; LANG=0 means English.
6. Execute 2496 in the command line of the network management interface to open the executable functions of clit.out:
SS:>2496 2496,CLI_TermAgent is open

END OF STEPS

Testing Telnet
Prerequisites

You have configured the foreground interface.

You have configured the background interface.

You have configured clit.out.

Context

This topic describes how to test the Telnet functions and execute
commands through Telnet.

Steps

1. Telnet from the maintenance terminal to the NIC IP address


and 6000 interface (taking 10.0.5.130 as an example) to see
whether the operator can enter the clit.out prompt:
telnet 10.0.5.130 6000
Welcome to SUSE Linux Enterprise Server 10 SP1 (i586) Kernel 2.6.16.46-0.12-bigsmp
node2 login: telnet
Password:
Last login: Tue Jan 15 16:54:29 CST 2002 from 10.0.5.217 on pts/9
[ZXSS10 CLI Remote Terminal]
[ZTE Corporation]
SS:>
SS:>2100:"root","root";
MyNE1:>

Note:
If the operator fails to Telnet to the destination, check the configurations.
2. In the prompt, use MML to test. Operators can seek help by
executing HELP. Remember, this HELP should be in uppercase:
MyNE1:>HELP 5004
Code
: 5004
Shortcut
: SHOW_REGISTER_MG
Level
: 3
Function
:
Show the information of the MG registered in Softswitch!
The
no.
1
2
3

input params :
type
name
INT\WORD MODULE
INT\DWORD S_NODEID
INT\DWORD L_NODEID

notes
MODULE
SMALL NODEID
LARGE NODEID

Confidential and Proprietary Information of ZTE CORPORATION

range
default
0-1024
0-4294967295 0
0-4294967295 4294967295

opt.
No
No
No

Chapter 1 PC Server Telnet Configurations

INT\WORD

ZONE

ZONE ID

0-65535

65535

No

Example :
5004:1=2;
Show the information of the MG Processed on module 2 in
Softswitch!
Note :
Module inputted should be right!
Two parameters: S_NODEID, L_NODEID were added to this version
comparing to the version 1.0. The two parameters have default
value: 0 and 4294967295. If want to look up the information
of all the registered MG, please select the default value of
the parameter 2, 3, 4.
relative command :
5000:SHOW_H248_STATIS(Show H248 Statis)
5002:RESET_MG(RESET MG)
5003:AUDIT_TGTID(AUDIT THE TERMINATIONID)

END OF STEPS

Confidential and Proprietary Information of ZTE CORPORATION

ZXSS10 SS1b PC Server Telnet Configuration

This page is intentionally blank.

Confidential and Proprietary Information of ZTE CORPORATION

Figures

Figure 1 Port Distribution..................................................... 2


Figure 2 Add Port Distribution .............................................. 3
Figure 3 Configuring 6000 Interface ...................................... 3
Figure 4 Port Visit Control List Configuration........................... 4
Figure 5 Add Port Visit Control List Configuration .................... 4
Figure 6 Configuring the Visit List of 6000 Interface ................ 4

Confidential and Proprietary Information of ZTE CORPORATION

S-ar putea să vă placă și