V100R003
Hardware Description
Issue
04
Date
2011-02-15
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Website:
http://www.huawei.com
Email:
support@huawei.com
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Product Version
The following table lists the product version related to this document.
Product Name
Product Version
BTS3900
V100R003
Intended Audience
This document is intended for:
l
System engineers
Organization
1 Changes in the BTS3900 Hardware Description
This describes the changes in the BTS3900 Hardware Description.
2 Exterior of the BTS3900 Cabinet
The BTS3900 cabinet is a vertical cabinet, which is designed in compliance with the IEC297
standard.
3 BTS3900 Hardware Configuration
Issue 04 (2011-02-15)
iii
BTS3900
Hardware Description
This section describes the cabinet, power system, transmission system, CPRI port, and
monitoring system configurations of the BTS3900, and provides reference for planning and
deploying the BTS3900.
4 BTS3900 Components
This describes the components of the BTS3900, which are the BBU3900, RFUs, DCDU-01,
FAN unit, DC/DC power system, AC/DC power system and optional modules. The AC/DC
power system is configured in the BTS3900 cabinet (220 V); the DC/DC power system is
configured in the BTS3900 cabinet (+24 V).
5 BTS3900 Cables
This chapter describes the BTS3900 cables. The BTS3900 cables consist of the PGND cable,
power cable, transmission cable, CPRI cable, signal cable, and RF cable.
6 BTS3900 Auxiliary Equipment
This chapter describes the auxiliary equipment of the BTS3900.
Conventions
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol
Description
Indicates a hazard with a high level of risk, which if not
avoided, will result in death or serious injury.
Indicates a hazard with a medium or low level of risk, which
if not avoided, could result in minor or moderate injury.
Indicates a potentially hazardous situation, which if not
avoided, could result in equipment damage, data loss,
performance degradation, or unexpected results.
Indicates a tip that may help you solve a problem or save
time.
Provides additional information to emphasize or supplement
important points of the main text.
General Conventions
The general conventions that may be found in this document are defined as follows.
iv
Convention
Description
Boldface
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Convention
Description
Italic
Courier New
Command Conventions
The command conventions that may be found in this document are defined as follows.
Convention
Description
Boldface
Italic
[]
{ x | y | ... }
[ x | y | ... ]
{ x | y | ... }*
[ x | y | ... ]*
GUI Conventions
The GUI conventions that may be found in this document are defined as follows.
Convention
Description
Boldface
>
Keyboard Operations
The keyboard operations that may be found in this document are defined as follows.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Format
Description
Key
Press the key. For example, press Enter and press Tab.
Key 1+Key 2
Key 1, Key 2
Mouse Operations
The mouse operations that may be found in this document are defined as follows.
vi
Action
Description
Click
Double-click
Drag
Press and hold the primary mouse button and move the
pointer to a certain position.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Contents
Contents
About This Document...................................................................................................................iii
1 Changes in the BTS3900 Hardware Description..................................................................1-1
2 Exterior of the BTS3900 Cabinet..............................................................................................2-1
3 BTS3900 Hardware Configuration..........................................................................................3-1
3.1 Board and Module Configurations..................................................................................................................3-2
3.1.1 Module Configurations in the Cabinet...................................................................................................3-2
3.1.2 Board Configurations of the BBU3900..................................................................................................3-5
3.2 Combinations of Cabinets.............................................................................................................................3-14
3.3 Power System of the BTS3900.....................................................................................................................3-18
3.3.1 Configurations of the Upper-Level Circuit Breaker and Power Cables...............................................3-19
3.3.2 Power Distribution of the BTS3900.....................................................................................................3-20
3.4 Transmission Board Configurations..............................................................................................................3-22
3.5 CPRI Port Configurations.............................................................................................................................3-23
3.5.1 CPRI Port Specifications......................................................................................................................3-23
3.5.2 Configuration Principles for the CPRI Ports on the RFU in the GSM Only Base Station..................3-25
3.5.3 Configuration Principles for the CPRI Ports on the RFU in the UMTS Only Base Station................3-27
3.5.4 Configuration Principles for the CPRI Ports on the RFU in the LTE Only Base Station....................3-29
3.5.5 Configuration Principles for the CPRI Ports on the RFU in the GSM+UMTS Base Station..............3-31
3.5.6 Configuration Principles for the CPRI Ports on the RFU in the GSM+LTE Base Station..................3-33
3.5.7 Configuration Principles for the CPRI Ports on the RFU in the UMTS+LTE Base Station...............3-35
3.6 BTS3900 Monitoring System........................................................................................................................3-36
3.6.1 BBU Monitoring Port...........................................................................................................................3-36
3.6.2 Monitoring Principles of the Cabinet ..................................................................................................3-37
3.6.3 Customized Alarm Inputs.....................................................................................................................3-39
3.7 RF Configurations.........................................................................................................................................3-41
3.7.1 RFU Configurations.............................................................................................................................3-42
3.7.2 Slot Assignment for the RFUs in a Base Station Working in GSM Only Mode.................................3-43
3.7.3 Slot Assignment for the RFUs in a Base Station Working in UMTS Only Mode...............................3-46
3.7.4 Slot Assignment for the RFUs in a Base Station Working in LTE Only Mode..................................3-47
3.7.5 Slot Assignment for the RFUs in a Base Station Working in GSM+UMTS Mode.............................3-50
3.7.6 Slot Assignment for the RFUs in a Base Station Working in GSM+LTE Mode.................................3-56
3.7.7 Slot Assignment for the RFUs in a Base Station Working in UMTS+LTE Mode..............................3-61
Issue 04 (2011-02-15)
vii
BTS3900
Hardware Description
Contents
4 BTS3900 Components................................................................................................................4-1
4.1 BBU3900 Equipment......................................................................................................................................4-3
4.1.1 Exterior of the BBU3900.......................................................................................................................4-3
4.1.2 Boards and Module of the BBU3900.....................................................................................................4-4
4.2 GRFU............................................................................................................................................................4-39
4.3 DRFU............................................................................................................................................................4-43
4.4 WRFU...........................................................................................................................................................4-49
4.5 MRFU............................................................................................................................................................4-53
4.6 LRFU.............................................................................................................................................................4-57
4.7 DCDU-01......................................................................................................................................................4-60
4.8 Fan Box.........................................................................................................................................................4-62
4.9 GATM...........................................................................................................................................................4-63
4.10 ELU.............................................................................................................................................................4-65
4.11 Power Equipment (DC/DC)........................................................................................................................4-65
4.11.1 Components of the Power Equipment (DC/DC)................................................................................4-66
4.11.2 PSU (DC/DC).....................................................................................................................................4-66
4.11.3 Power Subrack (DC/DC)....................................................................................................................4-68
4.12 Power Equipment (AC/DC)........................................................................................................................4-69
4.12.1 Components of the Power Equipment (AC/DC)................................................................................4-69
4.12.2 PMU...................................................................................................................................................4-70
4.12.3 PSU (AC/DC).....................................................................................................................................4-73
4.12.4 Power Subrack (AC/DC)....................................................................................................................4-75
5 BTS3900 Cables...........................................................................................................................5-1
5.1 List of BTS3900 Cables..................................................................................................................................5-3
5.2 BTS3900 Cable Connections..........................................................................................................................5-8
5.2.1 Power Cable Connections......................................................................................................................5-9
5.2.2 Transmission Cable Connections.........................................................................................................5-12
5.2.3 CPRI Cable Connections......................................................................................................................5-38
5.2.4 Monitoring Signal Cable Connections.................................................................................................5-50
5.2.5 RF Cable Connections..........................................................................................................................5-53
5.3 PGND Cables................................................................................................................................................5-66
5.4 Equipotential Cable.......................................................................................................................................5-67
5.5 BTS3900 Power Cable..................................................................................................................................5-68
5.5.1 Input Power Cable for the Cabinet.......................................................................................................5-68
5.5.2 Power Cable for the DCDU-01............................................................................................................5-70
5.5.3 Power Cable for the BBU.....................................................................................................................5-71
5.5.4 Power Cable for the Fan Box...............................................................................................................5-72
5.5.5 Power Cable for the RFU.....................................................................................................................5-72
5.5.6 Power Cable for the GATM.................................................................................................................5-73
5.6 BTS3900 Transmission Cable.......................................................................................................................5-74
5.6.1 E1/T1 Cable..........................................................................................................................................5-75
5.6.2 FE/GE Cable........................................................................................................................................5-77
viii
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Contents
Issue 04 (2011-02-15)
ix
BTS3900
Hardware Description
Figures
Figures
Figure 2-1 Exterior of a BTS3900 cabinet...........................................................................................................2-1
Figure 2-2 Dimensions of a BTS3900 cabinet.....................................................................................................2-2
Figure 3-1 Module configurations in the BTS3900 cabinet (-48 V DC)............................................................. 3-2
Figure 3-2 Module configurations in the BTS3900 cabinet (+24 V DC)............................................................ 3-3
Figure 3-3 Module configurations in the BTS3900 cabinet (AC)........................................................................3-3
Figure 3-4 Slots in the BBU3900.........................................................................................................................3-5
Figure 3-5 Typical configuration of the BBU3900 in GO mode.........................................................................3-6
Figure 3-6 Typical configuration of the BBU3900 in UO mode.........................................................................3-8
Figure 3-7 Typical configuration of the BBU3900 in LO mode..........................................................................3-9
Figure 3-8 Typical configuration of the BBU3900 in GU mode.......................................................................3-11
Figure 3-9 Typical configuration of the BBU3900 in GL mode........................................................................3-12
Figure 3-10 Typical configuration of the BBU3900 in UL mode......................................................................3-14
Figure 3-11 Two BTS3900 (-48 V DC) cabinets installed side by side.............................................................3-15
Figure 3-12 Two BTS3900 (+24 V DC) cabinets installed side by side............................................................3-15
Figure 3-13 Two BTS3900 (AC) cabinets installed side by side.......................................................................3-16
Figure 3-14 Two stacked BTS3900 (-48 V DC) cabinets..................................................................................3-17
Figure 3-15 Two stacked BTS3900 (AC) cabinets............................................................................................3-18
Figure 3-16 Power distribution of the BTS3900 (-48 V DC) cabinet................................................................3-20
Figure 3-17 Power distribution of the BTS3900 (+24 V DC) cabinet...............................................................3-21
Figure 3-18 Power distribution of the BTS3900 (AC) cabinet..........................................................................3-21
Figure 3-19 CPRI port connection principles.....................................................................................................3-25
Figure 3-20 Configuration principles for the CPRI ports in a single cabinet.....................................................3-26
Figure 3-21 Configuration principles for the CPRI ports in two cabinets.........................................................3-27
Figure 3-22 CPRI port connection principles.....................................................................................................3-28
Figure 3-23 CPRI port configuration principles (1)...........................................................................................3-28
Figure 3-24 CPRI port configuration principles (2)...........................................................................................3-29
Figure 3-25 CPRI port connection principles.....................................................................................................3-30
Figure 3-26 CPRI port configuration principles.................................................................................................3-30
Figure 3-27 CPRI port connection principles.....................................................................................................3-31
Figure 3-28 Configuration principles for the CPRI ports on the MRFUs (1)....................................................3-32
Figure 3-29 Configuration principles for the CPRI ports on the MRFUs (2)....................................................3-33
Figure 3-30 CPRI port connection principles.....................................................................................................3-34
Figure 3-31 Configuration principles for the CPRI ports on the MRFUs..........................................................3-34
Issue 04 (2011-02-15)
xi
BTS3900
Hardware Description
Figures
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Figures
xiii
BTS3900
Hardware Description
Figures
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Figures
Figure 5-35 Transmission cable connections in a base station in GSM 8E1/T1+LTE FE/GE mode (1)..........5-28
Figure 5-36 Transmission cable connections in a base station in GSM 8E1/T1+LTE FE/GE mode (2)..........5-29
Figure 5-37 Transmission cable connections in a base station in GSM FE/GE+LTE FE/GE mode (1)...........5-29
Figure 5-38 Transmission cable connections in a base station in GSM FE/GE+LTE FE/GE mode (2)...........5-30
Figure 5-39 Transmission cable connections for a UMTS+LTE base station in IP over E1 common transmission
mode (1)..............................................................................................................................................................5-30
Figure 5-40 Transmission cable connections for a UMTS+LTE base station in IP over E1 common transmission
mode (2)..............................................................................................................................................................5-31
Figure 5-41 Transmission cable connections for a UMTS+LTE base station in IP over FE/GE common
transmission mode (1).........................................................................................................................................5-31
Figure 5-42 Transmission cable connections for a UMTS+LTE base station in IP over FE/GE common
transmission mode...............................................................................................................................................5-32
Figure 5-43 Transmission cable connections for a UMTS+LTE base station in route backup mode with IP common
transmission (1)...................................................................................................................................................5-33
Figure 5-44 Transmission cable connections for a UMTS+LTE base station in route backup mode with IP common
transmission (2)...................................................................................................................................................5-33
Figure 5-45 Transmission cable connections in hybrid transmission mode (1).................................................5-34
Figure 5-46 Transmission cable connections in hybrid transmission mode (2).................................................5-35
Figure 5-47 Transmission cable connections in a base station in UMTS 4E1/T1+LTE FE/GE mode (1)........5-35
Figure 5-48 Transmission cable connections in a base station in UMTS 4E1/T1+LTE FE/GE mode (2)........5-36
Figure 5-49 Transmission cable connections in a base station in UMTS 8E1/T1+LTE FE/GE mode (1)........5-36
Figure 5-50 Transmission cable connections in a base station in UMTS 8E1/T1+LTE FE/GE mode (2)........5-37
Figure 5-51 Transmission cable connections in a base station in UMTS FE/GE+LTE FE/GE mode (1).........5-37
Figure 5-52 Transmission cable connections in a base station in UMTS FE/GE+LTE FE/GE mode (2).........5-38
Figure 5-53 Star topology...................................................................................................................................5-39
Figure 5-54 Chain topology...............................................................................................................................5-39
Figure 5-55 Star topology over CPRI ports........................................................................................................5-40
Figure 5-56 Chain topology over CPRI ports....................................................................................................5-40
Figure 5-57 Chain topology over CPRI ports on the WBBPd...........................................................................5-41
Figure 5-58 CPRI cable connections in the 3 x 10 MHz 2T2R configuration...................................................5-41
Figure 5-59 CPRI cable connections in the 3 x 20 MHz 2T2R configuration...................................................5-42
Figure 5-60 CPRI cable connections in the 3 x 10 MHz 4T4R configuration...................................................5-42
Figure 5-61 CPRI cable connections in the 3 x 20 MHz 4T4R configuration...................................................5-43
Figure 5-62 Dual-star topology over CPRI ports (1).........................................................................................5-43
Figure 5-63 Dual-star topology over CPRI ports (2).........................................................................................5-44
Figure 5-64 Dual-star topology over CPRI ports (3).........................................................................................5-44
Figure 5-65 Dual-star topology over CPRI ports (4).........................................................................................5-44
Figure 5-66 CPRI cable connections in a co-cabinet base station with WRFUs and DRFUs/GRFUs (1)........5-45
Figure 5-67 CPRI cable connections in a co-cabinet base station with WRFUs and DRFUs/GRFUs (2)........5-46
Figure 5-68 CPRI cable connections in a co-cabinet base station with MRFUs and WRFUs (1).....................5-47
Figure 5-69 CPRI cable connections in a co-cabinet base station with MRFUs and WRFUs (2).....................5-47
Figure 5-70 CPRI cable connections in a co-cabinet base station with MRFUs and DRFUs/GRFUs..............5-48
Figure 5-71 Dual-star topology over CPRI ports...............................................................................................5-49
Figure 5-72 CPRI cable connections in co-cabinet mode..................................................................................5-49
Issue 04 (2011-02-15)
xv
BTS3900
Hardware Description
Figures
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Figures
Issue 04 (2011-02-15)
xvii
BTS3900
Hardware Description
Tables
Tables
Table 3-1 Components in the cabinet...................................................................................................................3-4
Table 3-2 Principles for configuring the boards in the BBU3900 in GO mode...................................................3-6
Table 3-3 Principles for configuring the boards in the BBU3900 in UO mode...................................................3-7
Table 3-4 Principles for configuring the boards in the BBU3900 in LO mode...................................................3-8
Table 3-5 Principles for configuring the boards in the BBU3900 in GU mode.................................................3-10
Table 3-6 Principles for configuring the boards in the BBU3900 in GL mode................................................. 3-11
Table 3-7 Principles for configuring the boards in the BBU3900 in UL mode................................................. 3-13
Table 3-8 Applicable AC input voltage ranges..................................................................................................3-18
Table 3-9 Applicable DC input voltage ranges..................................................................................................3-19
Table 3-10 Recommended configurations of the upper-level circuit breaker and power cables....................... 3-19
Table 3-11 Transmission modes supported by the boards................................................................................. 3-22
Table 3-12 Specifications of the CPRI ports on the boards in the BBU............................................................3-24
Table 3-13 Specifications of the CPRI ports on the RFUs.................................................................................3-24
Table 3-14 Configuration principles for the CPRI ports in a single cabinet......................................................3-26
Table 3-15 Configuration principles for the CPRI ports in cabinet 1 of the two cabinets.................................3-27
Table 3-16 Configuration principles for the CPRI ports in cabinet 2 of the two cabinets.................................3-27
Table 3-17 CPRI port configuration principles (1)............................................................................................ 3-29
Table 3-18 CPRI port configuration principles (2)............................................................................................ 3-29
Table 3-19 CPRI port configuration principles..................................................................................................3-30
Table 3-20 Configuration principles for the CPRI ports on the MRFUs (1)......................................................3-32
Table 3-21 Configuration principles for the CPRI ports on the MRFUs (2)......................................................3-33
Table 3-22 Configuration principles for the CPRI ports on the MRFUs........................................................... 3-34
Table 3-23 CPRI port configuration principles..................................................................................................3-36
Table 3-24 Ports on the UPEU and UEIU..........................................................................................................3-37
Table 3-25 Configuration of monitoring boards in the BTS3900......................................................................3-39
Table 3-26 RFU configurations..........................................................................................................................3-42
Table 3-27 Slot assignment for GRFUs or DRFUs............................................................................................3-44
Table 3-28 Slot assignment for GRFUs or DRFUs............................................................................................3-45
Table 3-29 Slot assignment for GRFUs or DRFUs............................................................................................3-45
Table 3-30 Slot assignment for MRFUs and LRFUs in a single-band base station...........................................3-48
Table 3-31 Slot assignment for MRFUs and LRFUs in a dual-band base station..............................................3-49
Table 3-32 Slot assignment for GRFUs (or DRFUs) and WRFUs.................................................................... 3-51
Table 3-33 Slot assignment for GRFUs (or DRFUs) and WRFUs.................................................................... 3-52
Issue 04 (2011-02-15)
xix
BTS3900
Hardware Description
Tables
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Tables
xxi
BTS3900
Hardware Description
Tables
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Tables
Table 5-40 Transmission cable connections in a base station in GSM 8E1/T1+LTE FE/GE mode (1)............5-28
Table 5-41 Transmission cable connections in a base station in GSM 8E1/T1+LTE FE/GE mode (2)............5-29
Table 5-42 Transmission cable connections in a base station in GSM FE/GE+LTE FE/GE mode (1).............5-29
Table 5-43 Transmission cable connections in a base station in GSM FE/GE+LTE FE/GE mode (2).............5-30
Table 5-44 Transmission cables for a UMTS+LTE base station in IP over E1 common transmission mode (1)
.............................................................................................................................................................................5-30
Table 5-45 Transmission cables for a UMTS+LTE base station in IP over E1 common transmission mode (2)
.............................................................................................................................................................................5-31
Table 5-46 Transmission cables for a UMTS+LTE base station in IP over FE/GE common transmission mode (1)
.............................................................................................................................................................................5-32
Table 5-47 Transmission cables for a UMTS+LTE base station in IP over FE/GE common transmission mode
.............................................................................................................................................................................5-32
Table 5-48 Transmission cables for a UMTS+LTE base station in route backup mode with IP common transmission
(1)........................................................................................................................................................................5-33
Table 5-49 Transmission cables for a UMTS+LTE base station in route backup mode with IP common transmission
(2)........................................................................................................................................................................5-34
Table 5-50 Transmission cables in hybrid transmission mode (1).....................................................................5-34
Table 5-51 Transmission cables in hybrid transmission mode (2).....................................................................5-35
Table 5-52 Transmission cable connections in a base station in UMTS 4E1/T1+LTE FE/GE mode (1)..........5-35
Table 5-53 Transmission cable connections in a base station in UMTS 4E1/T1+LTE FE/GE mode (2)..........5-36
Table 5-54 Transmission cable connections in a base station in UMTS 8E1/T1+LTE FE/GE mode (1)..........5-37
Table 5-55 Transmission cable connections in a base station in UMTS 8E1/T1+LTE FE/GE mode (2)..........5-37
Table 5-56 Transmission cable connections in a base station in UMTS FE/GE+LTE FE/GE mode (1)..........5-38
Table 5-57 Transmission cable connections in a base station in UMTS FE/GE+LTE FE/GE mode (2)..........5-38
Table 5-58 Monitoring signal cable connections of the BTS3900 (-48 V DC).................................................5-51
Table 5-59 Monitoring signal cable connections of the BTS3900 (+24 V DC).................................................5-52
Table 5-60 Signal cable connections of the BTS3900 (AC)..............................................................................5-53
Table 5-61 -48 V power cable............................................................................................................................5-68
Table 5-62 +24 V power cable...........................................................................................................................5-69
Table 5-63 220 V power cable...........................................................................................................................5-70
Table 5-64 Power cable for the DCDU-01.........................................................................................................5-71
Table 5-65 Pin assignment of the power cable for the BBU..............................................................................5-72
Table 5-66 Pin assignment for the wires of the power cable for the fan box.....................................................5-72
Table 5-67 Pin assignment for the wires of the power cable for the RFU.........................................................5-73
Table 5-68 Pin assignment for the wires of the power cable for the GATM.....................................................5-74
Table 5-69 Connectors of the 75-ohm E1 coaxial cable.....................................................................................5-75
Table 5-70 Pin assignment for the wires of the 75-ohm E1 coaxial cable.........................................................5-76
Table 5-71 Pin assignment for the wires of the 120-ohm E1 twisted pair cable................................................5-76
Table 5-72 Pin assignment for the wires of the FE/GE cable............................................................................5-78
Table 5-73 Pin assignment for the wires of the monitoring signal cable for the PMU......................................5-81
Table 5-74 Pin assignment for the wires of the in-position signal cable for the PSU (DC/DC)........................5-83
Table 5-75 Pin assignment for the wires of the monitoring signal cable for the fan box...................................5-84
Table 5-76 Pin assignment of the fan box cascade signal cable.........................................................................5-85
Table 5-77 Pin assignment for the wires of the monitoring signal cable for the EMU......................................5-86
Issue 04 (2011-02-15)
xxiii
BTS3900
Hardware Description
Tables
Table 5-78 Pin assignment for the wires of the monitoring signal cable for the GATM...................................5-87
Table 5-79 Pin assignment for the wires of the BBU alarm cable.....................................................................5-88
Table 5-80 Pin assignment for the wires of the signal cable for the ELU..........................................................5-90
Table 6-1 Cables between the BTS3900 and the PS4890....................................................................................6-2
Table 6-2 Technical specifications of the DDF....................................................................................................6-4
xxiv
Issue 04 (2011-02-15)
BTS3900
Hardware Description
04 (2011-02-15)
This is the third commercial release.
Compared with issue 03 (2010-10-25), no topic is added.
Compared with issue 03 (2010-10-25), this issue incorporates the following change:
Contents
Change Description
FAN
UPEU
03 (2010-10-25)
This is the second commercial release.
Compared with issue 02 (2010-08-30), no topic is added.
Compared with issue 02 (2010-08-30), this issue incorporates the following change:
Contents
Change Description
1-1
BTS3900
Hardware Description
02 (2010-08-30)
This is the first commercial release.
Compared with issue 01 (2010-05-04), this issue is added with the following topic:
l
FMU
4.3 DRFU
3.5.4 Configuration Principles for the CPRI Ports on the RFU in the LTE Only Base
Station
3.5.6 Configuration Principles for the CPRI Ports on the RFU in the GSM+LTE Base
Station
3.5.7 Configuration Principles for the CPRI Ports on the RFU in the UMTS+LTE
Base Station
RF Configurations
Modification
01 (2010-05-04)
This is the draft release.
1-2
Issue 04 (2011-02-15)
BTS3900
Hardware Description
The BTS3900 cabinet is a vertical cabinet, which is designed in compliance with the IEC297
standard.
Figure 2-1 shows the exterior of a BTS3900 cabinet.
Figure 2-1 Exterior of a BTS3900 cabinet
Issue 04 (2011-02-15)
2-1
BTS3900
Hardware Description
2-2
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Issue 04 (2011-02-15)
3-1
BTS3900
Hardware Description
3-2
(1) RFU
(4) BBU3900
(5) DCDU-01
Issue 04 (2011-02-15)
BTS3900
Hardware Description
(1) RFU
(4) BBU3900
(5) DCDU-01
(1) RFU
Issue 04 (2011-02-15)
3-3
BTS3900
Hardware Description
(5) DCDU-01
3-4
Module
Optional or
Mandatory
Maximum
Number of
Boards or
Modules
Configured
in a Single
Cabinet
Remarks
RFU
Optional
RFU filler
panel
Optional
Fan box
Mandatory
BBU3900
Optional
DCDU-01
Mandatory
Power
equipment
(DC/DC)
Optional
Power
equipment
(AC/DC)
Optional
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Module
Optional or
Mandatory
Maximum
Number of
Boards or
Modules
Configured
in a Single
Cabinet
Remarks
Idle space
BBU3900 in GO Mode
Table 3-2 describes the principles for configuring the boards in the BBU3900 in GO mode.
Issue 04 (2011-02-15)
3-5
BTS3900
Hardware Description
Table 3-2 Principles for configuring the boards in the BBU3900 in GO mode
Board
Optional/
Mandatory
Maximum
Quantity
Slot
Configuration
Restriction
GTMU
Mandatory
Slots 5 and 6
Configured only
in slot 6 (both
slots 5 and 6 are
occupied)
FAN
Mandatory
Slot 16
Configured only
in slot 16
UPEU
Mandatory
Slot 18 or slot 19
Preferentially
configured in
slot 19 in the
case of a single
UPEU
USCU
Optional
Slot 0 or slot 1
Preferentially
configured in
slot 1
Configured in
slot 1 in the case
of 1 U dualsatellite-card (in
this case, slot 0
is also occupied)
UEIU
Optional
Slot 18
BBU3900 in UO Mode
Table 3-3 describes the principles for configuring the boards in the BBU3900 in UO mode.
3-6
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Table 3-3 Principles for configuring the boards in the BBU3900 in UO mode
Board
Optional/
Mandatory
Maximum
Quantity
Slot
Configuration
Restriction
WMPT
Mandatory
Slot 6 or slot 7
Preferentially
configured in
slot 7 in the case
of a single
WMPT
WBBP
Mandatory
Slots 0 to 3
Configured in
slot 3 by default:
l If an
expansion of
the CPRI
port is
required,
configure
the board in
slot 2.
l If an
expansion of
the CPRI
port is not
required,
configure
the board in a
slot, with
slot priority
of slot 0, slot
1, and slot 2.
Issue 04 (2011-02-15)
FAN
Mandatory
Slot 16
Configured only
in slot 16
UPEU
Mandatory
Slot 18 or slot 19
Preferentially
configured in
slot 19 in the
case of a single
UPEU
UEIU
Optional
Slot 18
UTRP
Optional
Slot 0, slot 1,
slot 4, and slot 5
Configured in a
slot, with slot
priority of slot 4,
slot 5, slot 0, and
slot 1
3-7
BTS3900
Hardware Description
Board
Optional/
Mandatory
Maximum
Quantity
Slot
Configuration
Restriction
USCU
Optional
Slot 1 or slot 0
Preferentially
configured in
slot 1
Configured in
slot 1 in the case
of 1 U dualsatellite-card (in
this case, slot 0
is also occupied)
BBU3900 in LO Mode
Table 3-4 describes the principles for configuring the boards in the BBU3900 in LO mode.
Table 3-4 Principles for configuring the boards in the BBU3900 in LO mode
3-8
Board
Optional/
Mandatory
Maximum
Quantity
Slot
Remarks
LMPT
Mandatory
Slot 6 or slot 7
Configured only
in slot 7 in the
case of a single
LMPT
LBBP
Mandatory
Slots 0 to 3
Configured in a
slot, with slot
priority of slot 3,
slot 1, and slot 2
in the case of a
single LBBP
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Board
Optional/
Mandatory
Maximum
Quantity
Slot
Remarks
FAN
Mandatory
Slot 16
Configured only
in slot 16
UPEU
Mandatory
Slot 18 or slot 19
Configured only
in slot 19 in the
case of a single
UPEU
UEIU
Optional
Slot 18
UTRP
Optional
Slot 4 or slot 5
Preferentially
configured in
slot 4
USCU
Optional
Slot 0, slot 1,
slot 4, or slot 5
Preferentially
configured in
slot 5 in the case
of a single
USCU;
configured in
slot 5 in the case
of 1 U USCU (in
this case, slot 4
is also occupied)
Preferentially
configured in
slot 1 if slot 4
and slot 5 are
occupied;
configured in
slot 1 in the case
of 1 U USCU (in
this case, slot 0
is also occupied)
Issue 04 (2011-02-15)
3-9
BTS3900
Hardware Description
BBU3900 in GU Mode
Table 3-5 describes the principles for configuring the boards in the BBU3900 in GU mode.
Table 3-5 Principles for configuring the boards in the BBU3900 in GU mode
Board
Optional/
Mandatory
Maximum
Quantity
Slot
Configuration
Restriction
WMPT
Mandatory
Slot 7
Configured only
in slot 7
GTMU
Mandatory
Slots 5 and 6
Configured only
in slot 6 (both
slots 5 and 6 are
occupied)
WBBP
Mandatory
Slots 0 to 3
Configured in a
slot, with slot
priority of slot 3,
slot 0, slot 1, and
slot 2
FAN
Mandatory
Slot 16
Configured only
in slot 16
UPEU
Mandatory
Slot 18 or slot 19
Configured only
in slot 19 in the
case of a single
UPEU
UEIU
Optional
Slot 18
UTRP
Optional
Slot 0, slot 1, or
slot 4
Configured in a
slot, with slot
priority of slot 4,
slot 0, and slot 1
USCU
Optional
Slot 0 or slot 1
Preferentially
configured in
slot 1
Configured in
slot 1 in the case
of 1 U dualsatellite-card (in
this case, slot 0
is also occupied)
3-10
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Board
Optional/
Mandatory
Maximum
Quantity
Slot
Configuration
Restriction
UBRI
Optional
Slot 2
For
V100R003C01,
the UBRI can be
installed in slot
1 or 2, and it is
preferrentially
installed in slot
2.
BBU3900 in GL Mode
Table 3-6 describes the principles for configuring the boards in the BBU3900 in GL mode.
Table 3-6 Principles for configuring the boards in the BBU3900 in GL mode
Issue 04 (2011-02-15)
Board
Optional/
Mandatory
Maximum
Quantity
Slot
Remarks
LMPT
Mandatory
Slot 7
Configured only
in slot 7
GTMU
Mandatory
Slots 5 and 6
Configured only
in slot 6 (both
slots 5 and 6 are
occupied)
LBBP
Mandatory
Slots 0 to 3
Configured in a
slot, with slot
priority of slot 3,
slot 1, and slot 2
FAN
Mandatory
Slot 16
Configured only
in slot 16
3-11
BTS3900
Hardware Description
Board
Optional/
Mandatory
Maximum
Quantity
Slot
Remarks
UPEU
Mandatory
Slot 18 or slot 19
Configured only
in slot 19 in the
case of a single
UPEU
UEIU
Optional
Slot 18
UTRP
Optional
Slot 0, slot 1, or
slot 4
Configured in a
slot, with slot
priority of slot 4,
slot 0, and slot 1
The slot priority
of the GO UTRP
is higher than
that of the LO
UTRP
USCU
Optional
Slot 0 or slot 1
Preferentially
configured in
slot 1
Configured in
slot 1 in the case
of 1 U dualsatellite-card (in
this case, slot 0
is also occupied)
UBRI
Optional
Slot 2
For
V100R003C01,
the UBRI can be
installed in slot
1 or 2, and it is
preferrentially
installed in slot
2.
3-12
Issue 04 (2011-02-15)
BTS3900
Hardware Description
BBU3900 in UL Mode
Table 3-7 describes the principles for configuring the boards in the BBU3900 in UL mode.
Table 3-7 Principles for configuring the boards in the BBU3900 in UL mode
Board
Optional/
Mandatory
Maximum
Quantity
Slot
Remarks
LMPT
Mandatory
Slot 6
Configured only
in slot 6
WMPT
Mandatory
Slot 7
Configured only
in slot 7
LBBP
Mandatory
Configured only
in slot 2 in the
case of a single
LBBP
WBBP
Mandatory
Slot 0, slot 1, or
slot 3
Configured in a
slot, with slot
priority of slot 3,
slot 0, and slot 1
in the case of a
single WBBP
FAN
Mandatory
Slot 16
Configured only
in slot 16
UPEU
Mandatory
Slot 18 or slot 19
Configured only
in slot 19 in the
case of a single
UPEU
UEIU
Optional
Slot 18
UTRP
Optional
Slot 0, slot 1,
slot 4, or slot 5
Configured in a
slot, with slot
priority of slot 4,
slot 5, slot 0, and
slot 1
The slot priority
of the UO UTRP
is higher than
that of the LO
UTRP
Issue 04 (2011-02-15)
3-13
BTS3900
Hardware Description
Board
Optional/
Mandatory
Maximum
Quantity
Slot
Remarks
USCU
Optional
Slot 0 or slot 1
Preferentially
configured in
slot 1
Configured in
slot 1 in the case
of 1 U dualsatellite-card (in
this case, slot 0
is also occupied)
By default, the primary cabinet is positioned on the left, and the secondary cabinet is
positioned on the right. If restricted by the actual situation in the equipment room, the
primary cabinet can be positioned on the right.
The BTS3900 (-48 V DC) cabinet, BTS3900 (+24 V DC) cabinet, and BTS3900 (AC)
cabinet support side-by-side installation mode.
NOTE
The primary cabinet is the cabinet that is configured with the BBU.
The secondary cabinet is the cabinet that is not configured with the BBU.
Figure 3-11, Figure 3-12, and Figure 3-13 show the side-by-side installation mode with two
cabinets.
3-14
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Figure 3-11 Two BTS3900 (-48 V DC) cabinets installed side by side
Figure 3-12 Two BTS3900 (+24 V DC) cabinets installed side by side
Issue 04 (2011-02-15)
3-15
BTS3900
Hardware Description
Stack Mode
The principles for stacking two cabinets are as follows:
l
The stacking of the BTS3900 (AC) cabinets is not recommended. If cabinets are stacked,
the highest operating temperature of the cabinets is 50C.
Figure 3-14 and Figure 3-15 show the stack mode with two cabinets.
3-16
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Issue 04 (2011-02-15)
3-17
BTS3900
Hardware Description
3-18
Rated Voltage
Working Voltage
220 V AC single-phase
220 V AC to 240 V AC
176 V AC to 290 V AC
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Rated Voltage
Working Voltage
220 V AC three-phase
220 V AC to 240 V AC
176 V AC to 290 V AC
110 V AC dual-live-wire
100 V AC to 120 V AC
90 V AC to 135 V AC
Rated Voltage
-48 V DC
-38.4 V DC to -57 V DC
+24 V DC
21.6 V DC to 29 V DC
Issue 04 (2011-02-15)
Power Supply
Requirement for
the Circuit
Breakers on
Customer
Equipment
Cross-Sectional
Area of the Power
Cable
Length of the
Power Cable
-48 V DC
2 x 80 A
16 mm2
15 m
+24 V DC
1 x 160 A or 2 x 100
A
25 mm2
15 m
200 V AC singlephase
1 x 63 A or 1 x 50 A
(both using the two-
6 mm2
40 m
3-19
BTS3900
Hardware Description
Power Supply
Requirement for
the Circuit
Breakers on
Customer
Equipment
110 V AC dual-livewire
220 V AC threephase
1 x 25 A or 1 x 32 A
(both using the threelevel magnetic blast
breaker)
Cross-Sectional
Area of the Power
Cable
Length of the
Power Cable
2.5 mm2
40 m
NOTE
NOTE
3-20
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Issue 04 (2011-02-15)
3-21
BTS3900
Hardware Description
Board
GSM/UMTS
Mode
Port
Port Capacity
WMPT
UMTS
Four channels
UTRP3
UMTS
Eight channels
IP over E1/T1
GTMU/
GTMUb
GSM
Four channels
WMPT
UMTS
Four channels
UTRP4
UMTS
Eight channels
UTRPb4
LTE
Eight channels
GTMU/
GTMUb
GSM
Four channels
UTRPb4
GSM
Four channels
GTMU/
GTMUb
GSM
10 Mbit/s and
100 Mbit/s
LMPT
LTE
10 Mbit/s, 100
Mbit/s, and
1000 Mbit/s
WMPT
UMTS
10 Mbit/s and
100 Mbit/s
UTRP2
UMTS
10 Mbit/s, 100
Mbit/s, and
1000 Mbit/s
GTMU/
GTMUb
GSM
10 Mbit/s and
100 Mbit/s
LMPT
LTE
10 Mbit/s, 100
Mbit/s, and
1000 Mbit/s
WMPT
UMTS
10 Mbit/s and
100 Mbit/s
Transmission
over FE/GE
optical cable
Transmission
over FE/GE
electrical cable
3-22
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Transmission
Mode
Board
GSM/UMTS
Mode
Port
Port Capacity
UTRP9
UMTS
10 Mbit/s, 100
Mbit/s, and
1000 Mbit/s
NOTE
l The GTMU/GTMUb is mandatory for the GSM mode. When the channels of the E1/T1 signals are
more than four, the UTRPb4 must be configured for E1/T1 signal transmission.
l The WMPT is mandatory for the UMTS mode. When the channels of the E1/T1 signals are more than
four, the UTRP3 or UTRP4 must be configured for E1/T1 signal transmission. When the transmission
rate for the FE optical cable is higher than 100 Mbit/s, the UTRP2 must be configured. When the
transmission rate for the FE electrical cable is more than 100 Mbit/s, the UTRP9 must be configured.
l The transmission over FE/GE optical cable is recommended for the LMPT.
3-23
BTS3900
Hardware Description
Number of CRPI
Ports
Transmission
Rate of the CPRI
Port
Supported
Topology
GTMU
1.25 Gbit/s
GTMUb
UBRI
WBBPa
1.25 Gbit/s
WBBPb
WBBPd
LBBPb
LBBPc
3-24
RFU
Number of CRPI
Ports
Transmission
Rate of the CPRI
Port
Supported
Topology
DRFU
1.25 Gbit/s
Star or chain
GRFU
1.25 Gbit/s
Star or chain
WRFU
Star or chain
MRFU
1.25 Gbit/s
Star
MRFU V2
Star
Issue 04 (2011-02-15)
BTS3900
Hardware Description
RFU
Number of CRPI
Ports
Transmission
Rate of the CPRI
Port
Supported
Topology
LRFU
Star
3.5.2 Configuration Principles for the CPRI Ports on the RFU in the
GSM Only Base Station
When a base station works in GSM mode, the DRFUs/GRFUs in the slots of the cabinet are
connected to the CPRI ports on the GTMU.
The DRFUs can be connected over the CPRI ports with a maximum of three levels of
cascading, the GRFUs can be connected over the CPRI ports with a maximum of two levels
of cascading, and the DRFUs and GRFUs can be connected over the CPRI ports with a
maximum of two levels of cascading. The data transmission rates over the CPRI ports of
the cascaded DRFUs/GRFUs are the same.
The CRPI1 port on the DRFU is connected to the GTMU, and the CPRI0 port is connected
to the lower-level RFU.
The CRPI0 port on the GRFU is connected to the GTMU, and the CPRI1 port is connected
to the lower-level RFU.
The CPRI port configuration principles in a base station with a single cabinet are shown in
Figure 3-20 and listed in Table 3-14. The CPRI ports corresponding to an idle slot in the
cabinet are idle.
Issue 04 (2011-02-15)
3-25
BTS3900
Hardware Description
Figure 3-20 Configuration principles for the CPRI ports in a single cabinet
Table 3-14 Configuration principles for the CPRI ports in a single cabinet
3-26
Slot
Number
of the
DRFU/
GRFU
Number
of the
CPRI
Port on
the
GTMU
CPRI0
CPRI1
CPRI2
CPRI3
CPRI4
CPRI5
The CPRI port configuration principles in a base station with two cabinets are shown in
Figure 3-21 and listed in Table 3-15 and Table 3-16.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Figure 3-21 Configuration principles for the CPRI ports in two cabinets
Table 3-15 Configuration principles for the CPRI ports in cabinet 1 of the two cabinets
Slot Number of the
DRFU/GRFU
0 and 1
2 and 3
4 and 5
Number of the
CPRI Port on the
GTMU
CPRI0
CPRI2
CPRI4
Table 3-16 Configuration principles for the CPRI ports in cabinet 2 of the two cabinets
Slot Number of the
DRFU/GRFU
0 and 1
2 and 3
4 and 5
Number of the
CPRI Port on the
GTMU
CPRI1
CPRI3
CPRI5
3.5.3 Configuration Principles for the CPRI Ports on the RFU in the
UMTS Only Base Station
When a base station works in UMTS mode, the WRFUs in the slots of the cabinet are connected
to the WBBPbs/WBBPds in the BBU.
Issue 04 (2011-02-15)
3-27
BTS3900
Hardware Description
The WRFUs can be connected over the CPRI ports with a maximum of two levels of
cascading. The two cascaded WRFUs work in the same sector and the data transmission
rates over the CPRI ports on the two WRFUs are the same.
The CRPI0 port on the WRFU is connected to the WBBP, and the CPRI1 port is connected
to the lower-level WRFU.
The CPRI port configuration principles in a base station configured with WBBPbs are
shown in Figure 3-23 and listed in Table 3-17.
Figure 3-23 CPRI port configuration principles (1)
3-28
Issue 04 (2011-02-15)
BTS3900
Hardware Description
MRFU
Slot
Number
Number
of the
WBBPb
in Slot3
CPRI0
CPRI1
CPRI2
The CPRI port configuration principles in a base station configured with WBBPds are
shown in Figure 3-24 and listed in Table 3-17.
Figure 3-24 CPRI port configuration principles (2)
Number
of the
WBBPd
in Slot3
CPRI0
CPRI2
CPRI4
3.5.4 Configuration Principles for the CPRI Ports on the RFU in the
LTE Only Base Station
When a base station works in LTE only mode, the RFUs in the cabinet are the LRFUs.
Issue 04 (2011-02-15)
3-29
BTS3900
Hardware Description
The LRFU can work in the star topology. The chain topology is not supported.
The CPRI port configuration principles are shown in Figure 3-26 and listed in Table 3-19.
Figure 3-26 CPRI port configuration principles
3-30
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Number
of the
CPRI
Port on
the LBBP
in Slot 3
CPRI0
CPRI2
CPRI4
3.5.5 Configuration Principles for the CPRI Ports on the RFU in the
GSM+UMTS Base Station
When a base station works in GSM+UMTS mode, the RFUs in the cabinet are the MRFUs, and
the boards configured in the BBU are the GTMU, UBRI, WMPT, and WBBPb/WBBPd.
The MRFU can work in dual-star topology rather than chain topology.
When the MRFU works in dual-star topology, the signals in the same mode cannot be
transmitted over two CPRI links.
Figure 3-27 shows the CPRI port connection principles for the MRFUs working in GSM+UMTS
mode.
Figure 3-27 CPRI port connection principles
The CPRI0 port on the MRFU is connected to the GTMU or UBRI for GSM data
transmission.
The CPRI1 port on the MRFU is connected to the WBBPb or WBBPd for UMTS data
transmission.
The configuration principles for the CPRI ports on the MRFUs are as follows:
Issue 04 (2011-02-15)
3-31
BTS3900
Hardware Description
The CPRI port configuration principles in a base station configured with WBBPbs are
shown in Figure 3-28 and listed in Table 3-20 and Table 3-21.
Figure 3-28 Configuration principles for the CPRI ports on the MRFUs (1)
Table 3-20 Configuration principles for the CPRI ports on the MRFUs (1)
MRFU
Slot
Number
Number
of the
CPRI
Port on
the
GTMU
CPRI0
CPRI1
CPRI2
CPRI3
CPRI4
CPRI5
Number
of the
WBBPb
in Slot3
CPRI0
CPRI1
CPRI2
Number
of the
WBBPb
in Slot2
CPRI0
CPRI1
CPRI2
The CPRI port configuration principles in a base station configured with WBBPds are
shown in Figure 3-29 and listed in Table 3-21.
3-32
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Figure 3-29 Configuration principles for the CPRI ports on the MRFUs (2)
Table 3-21 Configuration principles for the CPRI ports on the MRFUs (2)
MRFU
Slot
Number
Number
of the
CPRI
Port on
the
GTMU
CPRI0
CPRI1
CPRI2
CPRI3
CPRI4
CPRI5
Number
of the
WBBPd
in Slot3
CPRI0
CPRI1
CPRI2
CPRI3
CPRI4
CPRI5
3.5.6 Configuration Principles for the CPRI Ports on the RFU in the
GSM+LTE Base Station
When a base station works in GSM+LTE mode, the RFUs in the cabinet are the MRFUs, and
the boards configured in the BBU are the GTMU, UBRI, LMPT, and LBBP.
The MRFUs can work in the dual-star topology rather than chain topology.
When the MRFU works in the dual-star topology, the signals in the same mode cannot be
transmitted over two CPRI links.
Figure 3-30 shows the CPRI port connection principles for the MRFUs working in GSM+LTE
mode.
Issue 04 (2011-02-15)
3-33
BTS3900
Hardware Description
The CPRI0 port on the MRFU is connected to the GTMU or UBRI for GSM data
transmission.
The CPRI1 port on the MRFU is connected to the LBBP for LTE data transmission.
The CPRI port configuration principles are shown in Figure 3-31 and listed in Table 3-22.
Figure 3-31 Configuration principles for the CPRI ports on the MRFUs
Table 3-22 Configuration principles for the CPRI ports on the MRFUs
MRFU
Slot
Number
3-34
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Number
of the
CPRI
Port on
the
GTMU
CPRI0
CPRI1
CPRI2
CPRI3
CPRI4
CPRI5
Number
of the
CPRI
Port on
the LBBP
in Slot 3
CPRI0
CPRI1
CPRI2
CPRI3
CPRI4
CPRI5
3.5.7 Configuration Principles for the CPRI Ports on the RFU in the
UMTS+LTE Base Station
When a base station works in UMTS+LTE mode, the RFUs in the cabinet are the WRFUs and
LRFUs, and the boards configured in the BBU are the WMPT, WBBP, LMPT, and LBBP.
The WRFUs use the configuration principles for the CPRI ports on RFUs in UMTS mode.
The LRFUs use the configuration principles for the CPRI ports on RFUs in LTE mode.
The CPRI port connection principles in UMTS+LTE mode are shown in Figure 3-32 and listed
in Table 3-23.
Figure 3-32 CPRI port configuration principles
Issue 04 (2011-02-15)
3-35
BTS3900
Hardware Description
LRFU
Slot
Number
Number
of the
CPRI
Port on
the
WBBP in
Slot 3
CPRI0
CPRI2
CPRI4
Number
of the
CPRI
Port on
the LBBP
in Slot 2
CPRI1
CPRI3
CPRI5
3-36
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Board
Port
Connector
Quantity
Description
Slot19
UPEU
EXT-ALM0
RJ-45
connector
Port for
Boolean
inputs 8 to 11
EXT-ALM1
RJ-45
connector
Port for
Boolean
inputs 12 to
15
MON0
RJ-45
connector
Port for
RS485 input
0
MON1
RJ-45
connector
Port for
RS485 input
1
EXT-ALM0
RJ-45
connector
Port for
Boolean
inputs 0 to 3
EXT-ALM1
RJ-45
connector
Port for
Boolean
inputs 4 to 7
MON0
RJ-45
connector
Port for
RS485 input
0
MON1
RJ-45
connector
Port for
RS485 input
1
Slot18
UEIU
(optional)
3-37
BTS3900
Hardware Description
For details about the monitoring ports on the FMU, see 4.8 Fan Box. The FMU is configured
in the BTS3900 cabinet (-48 V DC), BTS3900 cabinet (+24 V DC), and BTS3900 cabinet
(AC). For details about the position of the FMU in the cabinet, see 3.1.1 Module
Configurations in the Cabinet and 4.8 Fan Box.
For details about the monitoring ports on the PMU, see 4.12.2 PMU. The PMU is
configured in the BTS3900 cabinet (AC). For details about the position of the PMU in the
cabinet, see 3.1.1 Module Configurations in the Cabinet.
This document describes monitoring principles of two BTS3900 cabinets. If cabinet 1 is not
configured, the monitoring cables connected to the cabinet are not required.
Figure 3-34 Monitoring system for the BTS3900 cabinet (-48 V DC)
Figure 3-35 Monitoring system for the BTS3900 cabinet (+24 V DC)
3-38
Issue 04 (2011-02-15)
BTS3900
Hardware Description
NOTE
For details about how to monitor the EMU, see the section Customized Alarm Inputs.
For details about the configuration of the customized alarms, see the related initial configuration
guide.
Monitoring Board
-48 V DC cabinet or
AC cabinet
None
UPEU
1 to 16
UPEU+UEIU
17 to 32
UPEU+UEIU+EMU
None
UPEU
+24 V DC cabinet
Issue 04 (2011-02-15)
3-39
BTS3900
Hardware Description
Cabinet Type
Monitoring Board
1 to 16
UPEU+UEIU+EMU
17 to 32
NOTE
l If backup power is required for the BBU, two UPEUs rather than UPEU+UEIU are configured.
l If three BTS3900 cabinets are configured, only one UEIU is required to monitor both RS485 and dry
contact alarms.
l Analog values can be monitored only by the EMU.
l The EMU with sensors can be configured according to site requirements.
3-40
The cable connection of the EMU in the BTS3900 cabinet (-48 V DC) and BTS3900 cabinet
(+24 V DC): The EMU is connected to the MON1 port on the UPEU in the BBU.
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
The cable connection of the EMU in the BTS3900 cabinet (AC): The EMU is connected
to the right RS232/RS422 port on the PMU in the AC/DC power equipment.
3.7 RF Configurations
The RFUs configured in a base station can be DRFUs, GRFUs, WRFUs, LRFUs, or MRFUs.
3.7.1 RFU Configurations
The RFUs configured in a base station can be MRFUs, DRFUs, GRFUs, WRFUs, or LRFUs.
3.7.2 Slot Assignment for the RFUs in a Base Station Working in GSM Only Mode
When a base station works in GSM only mode, the DRFU or GRFU slot assignment in a cabinet
must comply with specific principles.
3.7.3 Slot Assignment for the RFUs in a Base Station Working in UMTS Only Mode
When a base station works in UMTS only mode, the WRFU slot assignment in a cabinet must
comply with specific principles.
3.7.4 Slot Assignment for the RFUs in a Base Station Working in LTE Only Mode
When a base station works in LTE only mode, the LRFU or MRFU slot assignment in a cabinet
must comply with specific principles.
3.7.5 Slot Assignment for the RFUs in a Base Station Working in GSM+UMTS Mode
When a base station works in GSM+UMTS mode, the RFU slot assignment in a cabinet must
comply with specific principles.
3.7.6 Slot Assignment for the RFUs in a Base Station Working in GSM+LTE Mode
When a base station works in GSM+LTE mode, the RFU slot assignment in a cabinet must
comply with specific principles.
3.7.7 Slot Assignment for the RFUs in a Base Station Working in UMTS+LTE Mode
Issue 04 (2011-02-15)
3-41
BTS3900
Hardware Description
When a base station works in UMTS+LTE mode, the RFU slot assignment in a cabinet must
comply with specific principles.
Frequency
Band
Supported
RFU
Maximum
Number of
Supported
Carriers
Number of TX
and RX
Channels
EGSM 900
MHz
DRFU/GRFU/
MRFU V1/
MRFU V2
PGSM 900
MHz
DRFU/GRFU/
MRFU V1/
MRFU V2
DRFU/GRFU/
MRFU V1/
MRFU V2
l 2 carriers
(DRFU)
l 6 carriers
(GRFU)
l 6 carriers
(MRFU V1/
MRFU V2)
l 2T2R
(DRFU)
l 1T2R
(GRFU)
l 1T2R
(MRFU V1/
MRFU V2)
GRFU/MRFU
V1
850 MHz
WRFU
900 MHz
MRFU V1/
MRFU V2
2100 MHz
WRFU
l 2 or 4
carriers
(WRFU)
l 4 carriers
(MRFU V1/
MRFU V2)
l 1T2R
(WRFU)
l 1T2R
(MRFU V1/
MRFU V2)
AWS
LRFU
l 1 carrier
(LRFU)
l 1 carrier
(MRFU V2)
l 2T2R
(LRFU)
l 1T2R
(MRFU)
A base station
working in
GSM+UMTS
mode supports a
maximum of six
carriers, and a
maximum of
two carriers are
supported by the
UMTS side.
1T2R
UMTS only
(UO)
2600 MHz
900 MHz
MRFU V2
1800 MHz
GSM+UMTS
(GU)
3-42
MRFU V1/
MRFU V2
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Mode
Frequency
Band
Supported
RFU
Maximum
Number of
Supported
Carriers
Number of TX
and RX
Channels
GSM+LTE
(GL)
MRFU V1/
MRFU V2
A base station
working in
GSM+LTE
mode supports a
maximum of six
carriers, and one
carrier is
supported by the
LTE side.
1T2R
UMTS+LTE
(UL)
WRFU/LRFU
l 2 or 4
carriers
(WRFU)
l 1T2R
(WRFU)
l 1 carrier
(LRFU)
l 2T2R
(LRFU)
Numbering Scheme
l
The sectors in a base station working in GSM only mode are numbered from G1 in a
numerical order, for example G1 and G2. Low-frequency sectors are numbered from G1
to G6, and high-frequency sectors are numbered from G7 to G12.
The slots are numbered from 0 in a numerical order, for example slot 0, slot 1, and slot 2.
A slot can be identified through cabinet number+slot number, for example, slot 1 in cabinet
1 (primary RFC).
3-43
BTS3900
Hardware Description
Table 3-27 describes the slot assignment for GRFUs or DRFUs when not more than three singleband sectors are configured in a single RFC. If more than two GRFUs or DRFUs are configured
for G1, the GRFU or DRFU that is not inserted can be preferentially positioned in slot 2 in
cabinet 1. If more than two GRFUs or DRFUs are configured for G2, the GRFU or DRFU that
is not inserted can be preferentially positioned in slot 4 in cabinet 1. If more than two GRFUs
or DRFUs are configured for G3, the GRFU or DRFU that is not inserted can be preferentially
positioned in slot 3 in cabinet 1.
Table 3-27 Slot assignment for GRFUs or DRFUs
Sector Number
G1
G2
G3
Cabinet 1
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
If more than three single-band sectors are configured in a single RFC, GRFUs or DRFUs are
positioned in the slots from left to right in the RFC.
3-44
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Scenario 2: A dual-band base station supporting not more than three sectors for the band,
with the configuration of GRFUs or DRFUs
Table 3-28 describes the slot assignment for GRFUs or DRFUs when not more than three sectors
are configured for each band in a single RFC.
Table 3-28 Slot assignment for GRFUs or DRFUs
Sector
Number
G1
G2
G3
G7
G8
G9
Cabinet 1
Slot 0
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Scenario 2: A dual-band base station supporting not more than three sectors for each band,
with the configuration of GRFUs or DRFUs in two RFCs
If not more than three sectors are configured for each band, cabinet 1 is used for the band for
which more GRFUs or DRFUs are configured. Cabinet 2 is used for the other band. If the same
number of GRFUs or DRFUs are configured for each band, cabinet 1 is preferentially used for
900 MHz.
Table 3-29 Slot assignment for GRFUs or DRFUs
Issue 04 (2011-02-15)
Sector
Number
G1
G2
G3
G7
G8
G9
Cabinet 1
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
Cabinet 2
Slot 1 or 2
Slot 2 or 3
Slot 4 or 5
3-45
BTS3900
Hardware Description
If more than two GRFUs or DRFUs are configured for G1 or G7, the GRFU or DRFU that is
not inserted can be preferentially positioned in slot in G2 or G8. If more than two GRFUs or
DRFUs are configured for G2 or G8, the GRFU or DRFU that is not inserted can be preferentially
positioned in the slot in G1 or G7 and then in the slot in G3 or G9 when the slot is insufficient.
If more than two GRFUs or DRFUs are configured for G3 or G9, the GRFU or DRFU that is
not inserted can be preferentially positioned in slot in G2 or G8.
Numbering Scheme
l
The sectors in a base station working in UMTS only mode are numbered from U1 in a
numerical order, for example U1 and U2.
The slots are numbered from 0 in a numerical order, for example slot 0, slot 1, and slot 2.
A slot can be identified through cabinet number+slot number, for example, slot 1 in cabinet
1 (primary RFC).
Issue 04 (2011-02-15)
BTS3900
Hardware Description
If three WRFUs are configured for three sectors, the WRFUs are preferentially positioned in
slots 0, 2, and 4 in cabinet 1.
Figure 3-43 UMTS S1/1/1 (1W+1W+1W)
Issue 04 (2011-02-15)
3-47
BTS3900
Hardware Description
Numbering Scheme
l
The sectors in a base station working in LTE only mode are numbered from L1 in a
numerical order, for example L1 and L2. Low-frequency sectors are numbered from L1 to
L6, and high-frequency sectors are numbered from L7 to L12.
The slots are numbered from 0 in a numerical order, for example slot 0, slot 1, and slot 2.
A slot can be identified through cabinet number+slot number, for example, slot 1 in cabinet
1 (primary RFC).
When LRFUs are configured, they are preferentially positioned in the slots in cabinet 1.
That is, the LRFU configured for L1 is preferentially positioned in slot 0 and then slot 1 if
slot 0 is occupied. The LRFU configured for L2 is preferentially positioned in slot 2 and
then slot 3 if slot 2 is occupied. The LRFU configured for L3 is preferentially positioned
in slot 4 and then slot 5 if slot 4 is occupied.
When MRFUs are configured, they are preferentially positioned in the slots in cabinet 1.
That is, the MRFU configured for L1 is preferentially positioned in slot 0 and then slot 1
if slot 0 is occupied. The MRFU configured for L2 is preferentially positioned in slot 2 and
then slot 3 if slot 2 is occupied. The MRFU configured for L3 is preferentially positioned
in slot 4 and then slot 5 if slot 4 is occupied.
L1
L2
L3
LRFU
Slot 0 or 1 in cabinet
1
Slot 2 or 3 in cabinet
1
Slot 4 or 5 in cabinet
1
MRFU
Slot 0 or 1 in cabinet
1
Slot 2 or 3 in cabinet
1
Slot 4 or 5 in cabinet
1
3-48
Issue 04 (2011-02-15)
BTS3900
Hardware Description
If more than three single-band sectors are configured and LRFUs are configured, the LRFUs are
preferentially positioned in the slots from left to right in cabinet 1. If MRFUs are configured,
they are preferentially positioned in the slots from left to right in cabinet 1. After all the slots in
cabinet 1 are occupied, MRFUs can be positioned in the slots from left to right in cabinet 2.
Scenario 2: A dual-band base station, with the configuration of MRFUs and LFRUs
If three sectors are configured for each band, LRFUs are preferentially positioned in the slots in
cabinet 2. That is, the LRFU configured for L1 is preferentially positioned in slot 0 and then slot
1 if slot 0 is occupied. The LRFU configured for L2 is preferentially positioned in slot 2 and
then slot 3 if slot 2 is occupied. The LRFU configured for L3 is preferentially positioned in slot
4 and then slot 5 if slot 4 is occupied. MRFUs are preferentially positioned in the slots in cabinet
1. The MRFU configured for L1 is preferentially positioned in slot 0 and then slot 1 if slot 0 is
occupied. The MRFU configured for L2 is preferentially positioned in slot 2 and then slot 3 if
slot 2 is occupied. The MRFU configured for L3 is preferentially positioned in slot 4 and then
slot 5 if slot 4 is occupied. Table 3-31 describes the RFU slot assignment.
Table 3-31 Slot assignment for MRFUs and LRFUs in a dual-band base station
Issue 04 (2011-02-15)
Sector
Number
L1
L2
L3
L7
L8
L9
LRFU
Slot 0 or 1
in cabinet
2
Slot 2 or 3
in cabinet
2
Slot 4 or 5
in cabinet
2
MRFU
Slot 0 or 1
in cabinet
1
Slot 2 or 3
in cabinet
1
Slot 4 or 5
in cabinet
1
3-49
BTS3900
Hardware Description
If more than three sectors are configured for each band, LRFUs are preferentially positioned in
the slots from left to right in cabinet 2, and MRFUs are preferentially positioned in the slots from
left to right in cabinet 1. If more than six MRFUs are configured, MRFUs can be positioned in
the slots from left to right in cabinet 2 after all the slots in cabinet 1 are occupied. Then, LRFUs
are positioned to the right of the MRFUs.
3-50
The 3900 series macro base station of SRAN5.0 supports the configurations of MRFUs,
hybrid configurations of GRFUs and MRFUs, and hybrid configurations of GRFUs and
WRFUs. Hybrid configurations are used only for capacity expansion. The base station with
the hybrid configurations of GRFUs and MRFUs does not support MIMO.
In a base station, the RFUs in the same frequency band must be of the same type. For
example, in a GSM+UMTS base station with the configuration of GSM 900M S4/4/4/4
+UMTS 900M S1/1/1, four GSM sectors and three UMTS sectors are configured. In this
case, MRFUs rather than GRFUs or DRFUs must be configured for the GSM sectors.
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Numbering Scheme
l
The sectors in a base station working in GSM only mode are numbered from G1 in a
numerical order, for example G1 and G2. Low-frequency sectors are numbered from G1
to G6, and high-frequency sectors are numbered from G7 to G12.
The sectors in a base station working in UMTS only mode are numbered from U1 in a
numerical order, for example U1 and U2.
The sectors in a multi-mode base station are numbered from M1 in a numerical order, for
example M1 and M2. Low-frequency sectors are numbered from M1 to M6, and highfrequency sectors are numbered from M7 to M12.
The slots are numbered from 0 in a numerical order, for example slot 0, slot 1, and slot 2.
A slot can be identified through cabinet number+slot number, for example, slot 1 in cabinet
1 (primary RFC).
Issue 04 (2011-02-15)
Sector
Number
G1
G2
G3
U1
U2
U3
Cabinet 1
Slot 0
Slot 2
Slot 4
Slot 1
Slot 3
Slot 5
Cabinet 2
3-51
BTS3900
Hardware Description
Scenario 2: A dual-mode base station working in dual-band mode on the GSM side and
supporting not more than three sectors for each band, with the configuration of GRFUs
(or DRFUs) and WRFUs
If a dual-mode base station works in dual-band mode on the GSM side and not more than six
GSM GRFUs or DRFUs are configured, the GRFUs or DRFUs are evenly positioned in the slots
in cabinet 1. By default, WRFUs are positioned in slots 1, 3, and 5 in cabinet 2.
Table 3-33 Slot assignment for GRFUs (or DRFUs) and WRFUs
3-52
Secto
r
Num
ber
G1
G2
G3
G7
G8
G9
U1
U2
U3
Cabin
et 1
Slot 0
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Cabin
et 2
Slot 1
Slot 3
Slot 5
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Scenario 3: A dual-mode base station working in dual-band mode and supporting not more
than three sectors for each band, with the configuration of MRFUs
A base station supports not more than three sectors for each band and is configured with MRFUs
in dual-band mode. Low-frequency MRFUs are positioned in slots 0, 2, and 4 in cabinet 1, and
high-frequency MRFUs are positioned in slots 1, 3, and 5 in cabinet 1.
Table 3-34 RFU slot assignment for MRFUs
Issue 04 (2011-02-15)
Sector
Number
M1
M2
M3
M7
M8
M9
Cabinet 1
Slot 0
Slot 2
Slot 4
Slot 1
Slot 3
Slot 5
Cabinet 2
3-53
BTS3900
Hardware Description
Scenario 4: A dual-mode base station working in dual-band mode and supporting not more
than three sectors for each band, with the configuration of GRFUs (or DRFUs) and MRFUs
RFUs for each band are positioned separately. MRFUs are positioned in the slots in cabinet 1,
and GRFUs (or DRFUs) are positioned in the slots in cabinet 2.
Table 3-35 RFU slot assignment for GRFUs (or DRFUs) and MRFUs
3-54
Sector
Number
M1
M2
M3
G7
G8
G9
Cabinet 1
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
Cabinet 2
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Figure 3-51 GSM S4/4/4 & S8/8/8+UMTS 900M S2/2/2 (900M: 2M+2M+2M, 1800M: 2G+2G
+2G)
Scenario 5: A dual-mode base station supporting not more than three sectors for each
band, with the configuration of MRFUs, GRFUs (or DRFUs), and WRFUs
A dual-mode base station supports not more than three sectors for each band and is configured
with MRFUs, GRFUs (or DRFUs), and WRFUs. MRFUs and WRFUs are preferentially
positioned in the slots in cabinet 1. GRFUs (or DRFUs) are preferentially positioned in the slots
in cabinet 2.
Table 3-36 RFU slot assignment for MRFUs, GRFUs (or DRFUs), and WRFUs
Issue 04 (2011-02-15)
Secto
r
Num
ber
M1
U1
M2
U2
M3
U3
G1
G2
G3
Cabin
et 1
Slot 0
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Cabin
et 2
Slot 0
or 1
Slot 2
or 3
Slot 4
or 5
3-55
BTS3900
Hardware Description
The 3900 series macro base station of SRAN5.0 supports the configurations of MRFUs,
hybrid configurations of GRFUs and MRFUs, hybrid configurations of GRFUs and LRFUs,
and hybrid configurations of MRFUs and LRFUs. Hybrid configurations are used only for
capacity expansion. The base station with the hybrid configurations of GRFUs and MRFUs
does not support MIMO.
In a base station, the RFUs in the same frequency band must be of the same type.
Numbering Scheme
l
3-56
The sectors in a base station working in GSM only mode are numbered from G1 in a
numerical order, for example G1 and G2. Low-frequency sectors are numbered from G1
to G6, and high-frequency sectors are numbered from G7 to G12.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
The sectors in a base station working in LTE only mode are numbered from L1 in a
numerical order, for example L1 and L2.
The sectors in a multi-mode base station are numbered from M1 in a numerical order, for
example M1 and M2. Low-frequency sectors are numbered from M1 to M6, and highfrequency sectors are numbered from M7 to M12.
The slots are numbered from 0 in a numerical order, for example slot 0, slot 1, and slot 2.
A slot can be identified through cabinet number+slot number, for example, slot 1 in cabinet
1 (primary RFC).
M1
M2
M3
M7
M8
M9
Cabinet 1
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
Cabinet 2
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
Issue 04 (2011-02-15)
3-57
BTS3900
Hardware Description
Scenario 2: A dual-band base station, with the configuration of MRFUs and GRFUs
Table 3-38 Slot assignment for MRFUs and GRFUs in a dual-band base station
Sector
Number
M1
M2
M3
G7
G8
G9
Cabinet 1
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
Cabinet 2
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
Scenario 3: A dual-band base station, with the configuration of MRFUs and LRFUs
Table 3-39 Slot assignment for MRFUs and LRFUs in a dual-band base station
3-58
Sector
Number
M1
M2
M3
L1
L2
L3
Cabinet 1
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
Cabinet 2
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Scenario 4: A dual-band base station, with the configuration of DRFUs (or GRFUs) and
LRFUs
Table 3-40 Slot assignment for DRFUs (or GRFUs) and LRFUs in a dual-band base station
Issue 04 (2011-02-15)
Sector
Number
G1
G2
G3
L1
L2
L3
Cabinet 1
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
Cabinet 2
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
3-59
BTS3900
Hardware Description
Scenario 5: A tri-band base station, with the configuration of MRFUs, GRFUs, and LRFUs
Table 3-41 Slot assignment for MRFUs, GRFUs, and LRFUs in a tri-band base station
3-60
Secto
r
Num
ber
M1
M2
M3
G7
G8
G9
L1
L2
L3
Cabin
et 1
Slot 0
or 1
Slot 2
or 3
Slot 4
or 5
Cabin
et 2
Slot 0
Slot 2
Slot 4
Slot 1
Slot 3
Slot 5
Issue 04 (2011-02-15)
BTS3900
Hardware Description
Numbering Scheme
l
The sectors in a base station working in UMTS only mode are numbered from U1 in a
numerical order, for example U1 and U2.
The sectors in a base station working in LTE only mode are numbered from L1 in a
numerical order, for example L1 and L2.
The slots are numbered from 0 in a numerical order, for example slot 0, slot 1, and slot 2.
A slot can be identified through cabinet number+slot number, for example, slot 1 in cabinet
1 (primary RFC).
Issue 04 (2011-02-15)
3-61
BTS3900
Hardware Description
L1
L2
L3
U1
U2
U3
Cabinet 1
Slot 0 or 1
Slot 2 or 3
Slot 4 or 5
Cabinet 2
Slot 1
Slot 3
Slot 5
3-62
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
BTS3900 Components
4-1
BTS3900
Hardware Description
4 BTS3900 Components
The Electronic Label Unit (ELU) reports the cabinet type information to the fan box.
4.11 Power Equipment (DC/DC)
The power equipment (DC/DC) converts +24 V DC power into -48 V DC power.
4.12 Power Equipment (AC/DC)
The power equipment (AC/DC) converts 220 V AC power into -48 V DC power.
4-2
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Provides ports for communication between the base station and the BSC/RNC
Provides USB ports, which facilitates automatic base station upgrade by allowing a USB
disk to be used for software installation and data configuration
Provides an OM channel between the base station and the LMT or the M2000
The Electronic Serial Number (ESN) is unique to a network element (NE) for identification, and
is used during the commissioning of the base station.
l
Issue 04 (2011-02-15)
If there is a label on the FAN unit of the BBU, the ESN is printed on a label and the mounting
ears of the BBU. Figure 4-2 shows the position of the ESN.
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
4-3
BTS3900
Hardware Description
4 BTS3900 Components
If there is no label on the FAN unit of the BBU, the ESN is printed on the mounting ears
of the BBU. Figure 4-3 shows the position of the ESN.
Figure 4-3 The position of the ESN (2)
GTMU
The GSM Transmission & Timing & Management Unit for BBU (GTMU) is the basic
transmission and control function entity of the BBU. It provides the reference clock, maintenance
port, and external alarm collection port, monitors the power supply, and controls and manages
the entire base station.
Panel
The GTMU is classified into two types: GTMU and GTMUb. Figure 4-4 and Figure 4-5 show
the panels of the GTMU and GTMUb.
4-4
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
NOTE
Functions
The GTMU and GTMUb have the following functions:
l
Provides and manages the clock source of the base station in centralized mode
Provides CPRI ports for communication between the BBU and the RFUs
Four IDX2 ports on the backplane of the GTMUb can achieve the function of baseband
resource pool backup.
LEDs
Table 4-1 describes the LEDs on the GTMU.
Issue 04 (2011-02-15)
4-5
BTS3900
Hardware Description
4 BTS3900 Components
Color
Status
Description
RUN
Green
ON
OFF
ON
An alarm is generated,
indicating a running fault.
OFF
ON
OFF
ALM
ACT
Red
Green
Besides the preceding three LEDs, there are LEDs indicating the connection status of the FE
optical port, FE electrical port, CPRI port and commissioning port. Each of the LEDs is
positioned near the relevant port without any label on the panel of the board. Table 4-2 describes
the LEDs and their status.
Table 4-2 LEDs and their status
LED
Color
Status
Description
LIU0 to LIU3
Green
ON
An E1/T1 remote
alarm is generated.
OFF
The link is
functional.
Green
ON
Red
ON
ON
CPRI0 to CPRI5
ETH
4-6
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
LED
Color
FE0
FE1(GTMUb)
Status
Description
OFF
No connection is set
up.
Blinking
Data is being
transmitted.
OFF
No data is being
transmitted.
ON
OFF
No connection is set
up.
Blinking
Data is being
transmitted.
OFF
No data is being
transmitted.
ON
OFF
No connection is set
up.
Blinking
Data is being
transmitted.
OFF
No data is being
transmitted.
M_S (GTMUb)
EXT (GTMUb)
Ports
Table 4-3 describes the ports on the GTMU.
Table 4-3 Ports on the GTMU
Issue 04 (2011-02-15)
Label
Connector
Description
CPRI0 to CPRI5
SFP female
EXT (GTMUb)
SFP female
Obligate
4-7
BTS3900
Hardware Description
4 BTS3900 Components
Label
Connector
Description
ETH
RJ-45 connector
FE0
RJ-45 connector
FE1
DLC connector
USB
USB connector
TST
USB connector
E1/T1
DB26 female
connector
The RST button on the panel of the GTMU is used for resetting the board.
DIP Switches
On the GTMU, there are five DIP switches, each of which has four bits. DIP switches S1 and
S2 must be set together. The functions of the five DIP switches are as follows:
l
S1 is used to select the E1 resistance. Table 4-4 provides details on the DIP switch.
S2 is used to select the grounding mode of E1/T1 cables. Table 4-5 provides details on the
DIP switch.
S3 is reserved.
S4 is used to select the E1 bypass. Table 4-6 provides details on the DIP switch.
S5 is used for timeslot settings when the E1 bypass is selected. Table 4-7 provides details
on the DIP switch.
Bit Status
1
S1
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
Description
Others
4-8
Unavailable
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
NOTE
Bits 3 and 4 of S1 should be kept as out-of-factory state, without any manual setting on site. The out-offactory state should be OFF. If the bits are ON, set them to OFF.
Bit Status
Description
S2
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Others
Unavailable
Bit Status
1
S4
ON
ON
ON
ON
Supporting E1 bypass
OFF
OFF
OFF
OFF
Not supporting E1
bypass
Description
Others
Unavailable
Issue 04 (2011-02-15)
DIP
Switch
Bit Status
1
S5
ON
ON
ON
ON
Not supporting E1
bypass
OFF
ON
ON
OFF
Supporting E1 bypass
of level-1 cascaded
base stations
ON
OFF
ON
OFF
Supporting E1 bypass
of level-2 cascaded
base stations
Description
4-9
BTS3900
Hardware Description
4 BTS3900 Components
DIP
Switch
Bit Status
Description
OFF
OFF
ON
OFF
Supporting E1 bypass
of level-3 cascaded
base stations
ON
ON
OFF
OFF
Supporting E1 bypass
of level-4 cascaded
base stations
OFF
ON
OFF
OFF
Supporting E1 bypass
of level-5 cascaded
base stations
NOTE
The E1 bypass function is not supported in this version. All the bits of S4 should be set to OFF, and all the
bits of S5 should be set to ON.
WMPT
The WCDMA Main Processes and Transmission unit (WMPT) of the BBU3900 processes the
signals and manages the resources for other boards.
Panel
Figure 4-6 shows the panel of the WMPT.
Figure 4-6 Panel of the WMPT
Functions
The WMPT has the following functions:
4-10
Processes signaling and manages resources for other boards in the BBU3900
Provides USB ports, one of which facilitates automatic base station upgraded when a USB
disk is inserted during software installation and data configuration
Provides one FE electrical port and one FE optical port which support the IP protocol
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
LEDs
Table 4-8 describes the LEDs on the WMPT panel.
Table 4-8 LEDs on the WMPT panel
Label
Color
Status
Meaning
RUN
Green
ON
OFF
1s ON and 1s OFF
0.125s ON and
0.125s OFF
OFF
No alarm is
generated.
ON
ON
OFF
The board is in
standby mode.
ALM
ACT
Red
Green
In addition to the previous three LEDs, the WMPT has another six LEDs indicating the
connection status of the FE optical port, FE electrical port, and the commissioning Ethernet port.
The six LEDs have no silk screen and are on both sides of each of the three ports. Figure 4-7
shows the LEDs beside the three ports.
Figure 4-7 LEDs beside the three ports on the WMPT
Issue 04 (2011-02-15)
4-11
BTS3900
Hardware Description
4 BTS3900 Components
Color
Status
Meaning
Green (LINK)
ON
OFF
Blinking
Data transmission is
ongoing.
OFF
No data transmission
is ongoing.
ON
OFF
Blinking
Data transmission is
ongoing.
OFF
No data transmission
is ongoing.
ON
OFF
Blinking
Data transmission is
ongoing.
OFF
No data transmission
is ongoing.
Green (ACT)
Green (LINK)
Yellow (ACT)
ETH
Green (LINK)
Yellow (ACT)
Ports
Table 4-10 describes the ports on the WMPT panel.
Table 4-10 Ports on the WMPT panel
4-12
Label
Connector Type
Description
E1/T1
DB26 connector
E1/T1 port
FE0
RJ45 connector
FE electrical port
FE1
SFP connector
FE optical port
GPS
SMA connector
Obligate
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Label
Connector Type
Description
ETH
RJ45 connector
Commissioning Ethernet
port
USB
USB connector
TST
USB connector
RST
DIP Switches
The WMPT has two DIP switches: SW1 for setting the E1/T1 working mode and SW2 for setting
the protection grounding for the E1/T1 cables receiving 4-way signals. Figure 4-8 shows the
DIP switches on the WMPT.
Figure 4-8 DIP switches on the WMPT
Table 4-11 and Table 4-12 describe the settings of SW1 and SW2.
Table 4-11 Settings of SW1
Issue 04 (2011-02-15)
DIP
Switch
DIP Status
1
SW1
ON
ON
OFF
OFF
T1 Mode
OFF
OFF
ON
ON
The E1
impedance is
set to 120
ohms.
Description
4-13
BTS3900
Hardware Description
4 BTS3900 Components
DIP
Switch
DIP Status
Description
ON
ON
ON
ON
The E1
impedance is
set to 75
ohms.
Disabled
DIP Status
Description
SW2
OFF
OFF
OFF
OFF
Balanced
Mode
ON
ON
ON
ON
Unbalanced
Mode
Disabled
CAUTION
All the DIP bits of SW2 are set to OFF by default. When four E1 links are faulty, you should
set all the DIP bits of SW2 to ON so that the faults are rectified.
LMPT
The LTE Main Processing & Transmission unit (LMPT) manages the entire eNodeB system in
terms of OM and signaling processing and provides the clock for the BBU3900.
Panel
Figure 4-9 shows the LMPT.
Figure 4-9 LMPT
LMPT
LMPTb
4-14
TX
RX
SFP 0
TX
RX
SFP 1
RUN
ALM
ACT
USB TST
ETH
FE/GE0
FE/GE1
RST
GPS
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Functions
The LMPT has the following functions:
l
LEDs
There are three LEDs on the panel of the LMPT. Table 4-13 describes the LEDs on the LMPT.
Table 4-13 LEDs on the panel of the LMPT
Label
Color
Status
Description
RUN
Green
On
Off
On
An alarm is reported,
indicating a fault in the
board.
Off
On
Off
ALM
ACT
Issue 04 (2011-02-15)
Red
Green
4-15
BTS3900
Hardware Description
4 BTS3900 Components
Label
Color
Status
Description
Besides the preceding three LEDs, some other LEDs used for indicating the connection status
of the FE optical port, FE electrical port, commissioning Ethernet port have no silkscreen on the
board. They are near the ports. Table 4-14 describes the LEDs.
Table 4-14 Ports and LEDs
Label
Color
Status
Description
Green (LINK)
On
Off
No connection is set
up.
Blinking
Data is being
transmitted.
Off
No data is being
transmitted.
Blinking
Data is being
transmitted.
Off
No data is being
transmitted.
On
Off
No connection is set
up.
On
Off
No connection is set
up.
Blinking
Data is being
transmitted.
Off
No data is being
transmitted.
Orange (ACT)
ETH
Orange (ACT)
Green (LINK)
FE/GE0 to FE/GE1
Green (LINK)
Orange (ACT)
4-16
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Port
Table 4-15 describes the ports on the panel of the LMPT.
Table 4-15 Ports on the panel of the LMPT
Label
Connector Type
Quantity
Application
LC
USB
USB
Software loading
TST
USB
Testing
ETH
RJ45 connector
Commissioning
FE/GE0 to FE/GE1
RJ45 connector
Ethernet electrical
port, used for
connecting
transmission
equipment or gateway
equipment
GPS
SMA
RST
Resetting the
BBU3900
NOTE
SFP0 and FE/GE0 ports on the LMPT are used for one GE input. Therefore, they are not used
simultaneously.
SFP1 and FE/GE1 ports on the LMPT are used for another GE input. Therefore, they are not used
simultaneously.
WBBP
The WCDMA Baseband Process Unit (WBBP) of the BBU3900 processes baseband signals.
Panels
The WBBP has three types of panels, as shown in Figure 4-10, Figure 4-11 and Figure 4-12.
Figure 4-10 Panel of the WBBPa
Issue 04 (2011-02-15)
4-17
BTS3900
Hardware Description
4 BTS3900 Components
Functions
The WBBP has the following functions:
l
Provides the CPRI interface for communication between the BBU and the RRU or RFU,
and supports the CPRI interface in 1+1 backup mode.
When installed in slot 2 or slot 3, the WBBPd supports the IC function of uplink data.
Number of Cells
UL CE Number
DL CE Number
WBBPa
128
256
WBBPb1
64
64
WBBPb2
128
128
WBBPb3
256
256
WBBPb4
384
384
WBBPd1
192
192
WBBPd2
384
384
WBBPd3
256
256
LEDs
Table 4-17 describes the LEDs on the WBBP and their status.
4-18
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Color
Status
Description
RUN
Green
ON
OFF
ALM
Green
Red
ON
OFF
OFF
ON
The WBBPa or WBBPb provides three LEDs indicating the status of the SFP links. The LEDs
are positioned below the SFP ports. The WBBPd provides six LEDs indicating the status of the
SFP links. The LEDs are positioned above the SFP ports.
Table 4-18 describes the LEDs.
Table 4-18 LEDs indicating the status of the SFP links
Issue 04 (2011-02-15)
Label
Color
Status
Description
TX RX
Red/Green
Steady green
Steady red
OFF
4-19
BTS3900
Hardware Description
4 BTS3900 Components
Ports
Table 4-19 describes the three CPRI ports on the panels of the WBBPa and WBBPb.
Table 4-19 Ports on the panels of the WBBPa and WBBPb
Label
Connector Type
Description
CPRIx
SFP female
The WBBPd has six ports. Table 4-20 describes the ports on the WBBPd.
Table 4-20 Ports on the WBBPd
Label
Connector Type
Description
SFP female
CPRI3/EIH0, CPRI4/EIH1,
CPRI5/EIH2
NOTE
The six CPRI ports are available on the WBBPd configured only in slot 2 or 3, and the CPRI ports are not
available on the WBBPd configured in other port.
LBBP
The LTE BaseBand Processing unit (LBBP) in the BBU3900 processes the baseband signals.
Panel
The LBBP has two types of panels, as shown in Figure 4-13 and Figure 4-14.
Figure 4-13 Panel of the LBBPb
LBBP
LBBPb
TX
RX TX
CPRI 0
RX TX
CPRI 1
RX TX
CPRI 2
RX TX
CPRI 3
RX TX
CPRI 4
RX
RUN
ALM
ACT
CPRI 5
4-20
TX
RX TX
CPRI 0
RX TX
CPRI 1
RX TX
CPRI 2
RX TX
CPRI 3
RX TX
CPRI 4
RX
RUN
ALM
ACT
CPRI 5
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
NOTE
The LBBPc can be used in both LTE FDD and LTE TDD modes, and the LBBPb can be used in only LTE
FDD mode.
Function
The LBBP has the following functions:
l
Table 4-21 describes the specifications of the LBBP working in LTE FDD mode.
Table 4-21 Specifications of the LBBP
Board
Number of Cells
Bandwidth of the
Cell
Antenna
Configuration
LBBPb
10M
2T2R
20M
2T2R
10M
4T4R
20M
2T2R
10M
4T4R
20M
4T4R
LBBPc
Table 4-22 describes the specifications of the LBBP working in LTE TDD mode.
Table 4-22 Specifications of the LBBP
Board
Number of Cells
Bandwidth of the
Cell
Antenna
Configuration
LBBPc
20M
2T2R
10M
4T4R
20M
4T4R
8T8R
LED
There are three LEDs on the panel of the LBBP. Table 4-23 describes the LEDs on the LBBP.
Issue 04 (2011-02-15)
4-21
BTS3900
Hardware Description
4 BTS3900 Components
Color
Status
Description
RUN
Green
On
Off
On
An alarm is reported,
indicating a fault in
the board.
Off
On
Off
ALM
ACT
Red
Green
The LBBP provides six LEDs indicating the status of the SFP links. The LEDs are positioned
above the SFP ports. Table 4-24 describes the LEDs.
Table 4-24 LEDs indicating the status of the SFP links
4-22
Label
Color
Status
Description
TX RX
Red/Green
Steady green
Steady red
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Label
Color
Status
Description
Off
Port
Table 4-25 describes the ports on the panel of the LBBP.
Table 4-25 Ports on the LBBP
Label
Connector
Quantity
Description
CPRI0 to CPRI5
SFP female
FAN
The FAN unit for the BBU3900 controls the speed of fans and monitors the temperature of the
fan unit. It reports the status of the fans and fan unit, and dissipates heat from the BBU.
Panels
The FAN unit has two types of exterior, which are shown in Figure 4-15 and Figure 4-16.
Issue 04 (2011-02-15)
4-23
BTS3900
Hardware Description
4 BTS3900 Components
NOTE
The FANc has FANc label, which is different from the FAN.
Functions
The FAN unit performs the following functions:
l
Reports the status, temperature, and in-position signal of the fans to the main control
processing unit.
Dissipates heat.
The FANc supports the function of reading and writing the information reported by the
electronic label unit.
LED
The FAN panel has only one LED, which indicates the operating status of the fans. Table
4-26 describes the LED.
4-24
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Color
State
Meaning
STATE
Green
The module is
functional.
Off
No alarm is
generated.
Red
UPEU
The Universal Power and Environment Interface Unit (UPEU) for the BBU3900 converts -48
V DC or +24 V DC power into +12 V DC.
Panels
The UPEU is classified into three types: Universal Power and Environment Interface Unit Type
A (UPEUa), Universal Power and Environment Interface Unit Type B (UPEUb), and Universal
Power and Environment Interface Unit Type C (UPEUc). The UPEUa and UPEUc convert -48
V DC power into +12 V DC, and the UPEUb converts +24 V DC power into +12 V DC. Figure
4-17, Figure 4-18, and Figure 4-19 show the panels of the UPEUa, UPEUb, and UPEUc
respectively.
Figure 4-17 UPEUa panel
Issue 04 (2011-02-15)
4-25
BTS3900
Hardware Description
4 BTS3900 Components
The UPEUa and UPEUb are differentiated by the silkscreens on the panels, which display -48 V and +24
V respectively. The UPEUc has UPEUc label, which is different from the UPEUa.
Functions
The UPEU performs the following functions:
l
Converts -48 V DC or +24 V DC power into +12 V DC, which is the operating voltage of
the boards.
Provides two RS485 signal ports with each transmitting one RS485 signal and two Boolean
signal ports with each transmitting four Boolean signals.
LED
The UPEU has one LED, which indicates the operating status of the UPEU. Table 4-27 describes
the LED.
4-26
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Color
State
Meaning
RUN
Green
On
The UPEU is
working properly.
Off
Ports
The UPEU has two RS485 signal ports with each transmitting one RS485 signal and two Boolean
signal ports with each transmitting four Boolean signals. When the UPEU is configured in
different slots, the ports on the UPEU have different functions. Figure 4-20 shows the slots in
the BBU.
Figure 4-20 Slots in the BBU
Label
Connecto
r
Quantity
Description
Slot 19
+24 V or
-48 V
3V3
EXTALM0
RJ-45
EXTALM1
RJ-45
MON0
RJ-45
MON1
RJ-45
+24 V or
-48 V
3V3
EXTALM0
RJ-45
Slot 18
Issue 04 (2011-02-15)
4-27
BTS3900
Hardware Description
4 BTS3900 Components
Slot
Label
Connecto
r
Quantity
Description
EXTALM1
RJ-45
MON0
RJ-45
MON1
RJ-45
UEIU
The Universal Environment Interface Unit (UEIU) transmits monitoring and alarm signals from
the external devices to the main control and transmission unit.
Panel
Figure 4-21 shows the panel of the UEIU.
Figure 4-21 Panel of the UEIU
Functions
The UEIU performs the following functions:
l
Transmits monitoring signals and alarm signals from external devices to the main control
and transmission unit.
Ports
The UEIU is configured in slot 18. It provides four ports with two ports transmitting two RS485
input signals and the other two ports transmitting eight Boolean signals.
Table 4-29 describes the ports on the panel of the UEIU.
4-28
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Label
Connect
or
Quanti
ty
Description
slot 18
EXTALM0
RJ-45
EXTALM1
RJ-45
MON0
RJ-45
MON1
RJ-45
USCU
This section describes the Universal Satellite card and Clock Unit (USCU).
Panel
There are two types of USCU: USCUb1 and USCUb2, as shown in Figure 4-22 and Figure
4-23.
Figure 4-22 Panel of the USCUb1 (0.5 U)
Functions
The USCU has the following functions:
Issue 04 (2011-02-15)
4-29
BTS3900
Hardware Description
4 BTS3900 Components
The USCU provides interface for an external RGPS device (such as a reused device of the
operator), Metro1000 device, BITS device, and TOD input.
The USCUb1 has the GPS receiver. It is used for clock synchronization or obtaining
accurate clock signals from transmission devices.
LED
Table 4-30 and Table 4-31 describe the LEDs on the USCU.
Table 4-30 LEDs on the USCU
LED
Color
Status
Description
RUN
Green
On
Off
Off
On
On
Off
ALM
ACT
4-30
Red
Green
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Meaning
Default Configuration
Green
Yellow
Ports
Table 4-32 describes the ports on the USCU.
Table 4-32 Ports on the USCU
Port
Connector
Description
GPS port
SMA coaxial
connector
RGPS port
PCB welded
wiring terminal
TOD0 port
RJ-45 connector
TOD1 port
RJ-45 connector
BITS port
SMA coaxial
connector
M-1PPS port
SMA coaxial
connector
UTRP
This describes the Universal Transmission Processing unit (UTRP) board. As the transmission
extension board of the BBU3900, the UTRP provides eight E1s/T1s, one unchannelized STM-1/
OC-3 port, four electrical ports, or two optical ports.
Specification
Table 4-33 describes the specifications of the UTRP.
Issue 04 (2011-02-15)
4-31
BTS3900
Hardware Description
4 BTS3900 Components
Sub-board/Board Type
Port
UTRP2
UEOC
UTRP3
UAEC
UTRP4
UIEC
UTRPb4
UTRP6
UUAS
UTRP9
UQEC
Panels
Figure 4-24 shows the panel of the UTRP2 supporting two optical ports.
Figure 4-24 Panel of the UTRP2 supporting two optical ports
Figure 4-25 shows the panel of the UTRP3, UTRP4, and UTRPb4 supporting eight E1s/T1s.
Figure 4-25 Panel of the UTRP3, UTRP4, and UTRPb4 supporting eight E1s/T1s
UTRP
RUN
ALM
ACT
E1/T1(0-3)
E1/T1(4-7)
Figure 4-26 shows the panel of the UTRP6 supporting one STM-1.
Figure 4-26 Panel of the UTRP6 supporting one STM-1
Figure 4-27 shows the panel of the UTRP9 supporting four electrical ports.
4-32
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Functions
The UTRP has the following functions:
l
The UTRP2 provides two 100M/1000M Ethernet optical ports, performs functions of the
MAC layer, receives and transmits data on Ethernet links, and analyzes the MAC address.
The UTRP3 provides eight E1s/T1s and performs inverse multiplexing and demultiplexing
on a single ATM cell flow on the eight E1/T1 links.
The UTRP4 provides eight E1s/T1s, frames and deframes HDLC frames, and allocates and
controls the 256 HDLC timeslot channels.
The UTRP4 provides an E1/T1 port for four TDM transmission links in GSM mode and
provides a port for four transmission links in another mode for co-transmission in a dualmode base station.
The UTRP9 provides four 10M/100M/1000M Ethernet electrical ports and performs the
functions of the MAC layer and physical layer.
LEDs
Table 4-34 describes the LEDs on the panel of the UTRP.
Table 4-34 LEDs on the panel of the UTRP
Issue 04 (2011-02-15)
Label
Color
Status
Description
RUN
Green
ON
OFF
4-33
BTS3900
Hardware Description
4 BTS3900 Components
Label
Color
Status
Description
ALM
Red
ON or blinking
rapidly
The board is
reporting alarms.
OFF
The board is
reporting a minor
alarm.
The board is
reporting a major
alarm.
The board is
reporting a critical
alarm.
ON
OFF
The board is in
standby mode.
ACT
Green
UTRP2 and UTRP9 provide two LEDs for indicating the status of the current link. Table
4-35 describes the LEDs on the Ethernet ports of the UTRP2 and UTRP9.
Table 4-35 LEDs on the Ethernet ports of the UTRP2 and UTRP9
Label
Color
Status
Description
LINK
Green
OFF
The link is
disconnected.
ON
Blinking
OFF
ACT
Orange
Ports
Table 4-36 describes the ports of the UTRP2 supporting two optical ports.
4-34
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Port Type
Quantity
Connector Type
FE/GE0 to FE/GE1
SFP connector
Table 4-37 describes the ports on the UTRP3 and UTRP4 supporting eight E1s/T1s.
Table 4-37 Ports on the panel of the UTRP3, UTRP4 an UTRPb4 supporting eight E1s/T1s
Label
Port Type
Quantity
Connector Type
E1/T1
E1/T1 port
DB26 connector
Table 4-38 describes the port of the UTRP6 supporting one STM-1.
Table 4-38 Port of the UTRP6 supporting one STM-1
Label
Port Type
Quantity
Connector Type
STM-1/OC-3
STM-1/OC-3 port
SFP connector
Table 4-39 describes the ports of the UTRP9 supporting four electrical ports.
Table 4-39 Ports of the UTRP9 supporting four electrical ports
Label
Port Type
Quantity
Connector Type
FE/GE0 to FE/GE3
RJ-45 connector
DIP Switches
There is no DIP switch on the UTRP2, UTRP6, and UTRP9.
The UTRP3, UTRP4, or UTRPb4 has three DIP switches numbered from SW1 to SW3. SW1
and SW2 are used to set the grounding status of the eight E1s. SW3 is used to set matched
impedance for the eight E1s. Figure 4-28 shows the DIP switch on the UTRP3 or UTRP4,
Figure 4-29 shows the DIP switch on the UTRPb4.
Figure 4-28 DIP switch on the UTRP3 or UTRP4
Issue 04 (2011-02-15)
4-35
BTS3900
Hardware Description
4 BTS3900 Components
Table 4-40, Table 4-41, and Table 4-42 describe how to set the DIP switches on the UTRP.
Table 4-40 DIP switch SW1 on the UTRP
DIP
Switch
SW1
DIP Status
Description
OFF
OFF
OFF
OFF
Balanced
Mode
ON
ON
ON
ON
Unbalanced
Mode
Disabled
DIP Status
1
SW2
OFF
OFF
OFF
OFF
Balanced
Mode
ON
ON
ON
ON
Unbalanced
Mode
Description
4-36
Disabled
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
CAUTION
SW1 and SW2 are set to OFF (balanced mode) by default. When the eight E1s are faulty, all the
DIP bits of SW1 and SW2 should be set to ON to rectify faults. SW1 corresponds to E1s No.4
to No.7 and SW2 corresponds to E1s No.0 to No.3.
DIP Status
Description
OFF
OFF
ON
ON
T1 Mode
ON
ON
OFF
OFF
The E1
impedance is
set to 120
ohms.
ON
ON
ON
ON
The E1
impedance is
set to 75
ohms.
Disabled
UBRI
The Universal Baseband Radio Interface Board (UBRI) provides extended CPRI optical or
electrical ports to implement convergence, distribution, and multi-mode transmission on the
CPRI.
Panel
Figure 4-30 shows the panel of the UBRI.
Figure 4-30 Panel of the UBRI
Functions
The UBRI performs the following functions:
l
Issue 04 (2011-02-15)
4-37
BTS3900
Hardware Description
4 BTS3900 Components
LEDs
Table 4-43 describes the LEDs on the panel of the UBRI.
Table 4-43 LEDs on the panel of the UBRI
LED
Color
State
Description
RUN
Green
ON steady
There is power
supply, but the board
is faulty.
OFF steady
There is no power
supply, or the board
is in the alarm status.
1s ON, 1s OFF
ON or blinking at a
high frequency
OFF steady
No alarm is
generated.
ON steady
OFF steady
ALM
ACT
Red
Green
The UBRI provides six LEDs indicating the status of the CRRI links, which are above the SFP
ports. Table 4-44 describes the CPRI link status LED.
Table 4-44 CPRI link status LED
4-38
Label
Color
State
Description
CPRIx
Red/Green
ON (green)
ON (red)
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Ports
Table 4-45 describes the ports on the panel of the UBRI.
Table 4-45 Ports on the panel of the UBRI
Label
Connector
Port Quantity
Description
CPRI0 to CPRI5
SFP
4.2 GRFU
The GSM Radio Frequency Unit (GRFU) is designed on the basis of multi-transceiver
technology. One GRFU supports 6 carriers.
Panel
Figure 4-31 shows the GRFU panel.
Figure 4-31 GRFU panel
Issue 04 (2011-02-15)
4-39
BTS3900
Hardware Description
4 BTS3900 Components
Functions
The GRFU performs modulation and demodulation of baseband signals and RF signals,
processes data, and combines or divides signals.
The GRFU has the following functions:
l
Implements the direct frequency conversion technique in the transmit channel, modulates
the baseband signals to GSM RF signals; then sends the signals to the antenna for
transmission through the duplex filter after filtering, amplifying, and combining the RF
signals (the combining can be performed as required)
Provides power control and Voltage Standing Wave Ratio (VSWR) detection
Generates the CPRI clock, recovers the CPRI clock of lost synchronization, and detects
alarms
The GRFU consists of the high-speed interface unit, signal processing unit, power amplifier,
and duplexer. Figure 4-32 shows the logical structure of the GRFU.
Figure 4-32 Logical structure of the GRFU
Transmits the signals received from the BBU to the signal processing unit
Transmits the signals received from the signal processing unit to the BBU
The signal processing unit consists of two UL RX channels and one DL TX channel.
l
4-40
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
The power amplifier amplifies the low-power RF signals from the signal processing unit.
The duplexer has the following functions:
l
LEDs
The six LEDs on the GRFU panel indicate the operating status of the GRFU. Table 4-46
describes the LEDs on the GRFU panel.
Table 4-46 LEDs on the GRFU panel
Label
RUN
ALM
ACT
Issue 04 (2011-02-15)
Color
Green
Red
Green
State
Description
ON
OFF
ON
OFF
No alarm is generated.
ON
4-41
BTS3900
Hardware Description
4 BTS3900 Components
Label
VSWR
CPRI0
CPRI1
Color
Red
Red/Green
Red/Green
State
Description
ON (red)
OFF (red)
On (green)
On (red)
OFF
On (green)
On (red)
OFF
Ports
Table 4-47 describes the ports on the GRFU panel.
Table 4-47 Ports on the GRFU panel
Port
Label
Connector
Description
RF port
ANT_RXB
DIN
ANT_TX/
RXA
DIN
CPRI0
SFP female
CPRI
4-42
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Port
Label
Connector
Description
CPRI1
SFP female
Interconnectio
n port for RF
RX signals
RX_INB
QMA female
RX_OUTA
QMA female
Power supply
socket
PWR
3V3 power
Feeding power
Monitoring
port
MON
RJ-45
Monitoring port
4.3 DRFU
The Double Radio Frequency Unit (DRFU) is a dual-density RF unit. A DRFU processes two
carriers.
Panel
There are two types of DRFU, that is, the DRFU of 900 MHz and DRFU of 1800 MHz. The
panels of the DRFUs are shown in Figure 4-33 and Figure 4-34.
Issue 04 (2011-02-15)
4-43
BTS3900
Hardware Description
4 BTS3900 Components
4-44
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
NOTE
Functions
The DRFU performs modulation and demodulation of baseband and RF signals, processes data,
combines and divides the signals.
Both the DRFU of 900 MHz and DRFU of 1800 MHz perform the following functions:
l
Adopts the direct frequency conversion technology, modulates the baseband signals to the
GSM TX band. After filtering and amplification, the baseband signals are transmitted to
the antenna system through the duplex filter.
Receives uplink RF signals from the antenna system and then down-converts the received
signals to IF signals. After amplification, analog-to-digital conversion, digital downconversion, matched filtering, automatic gain control (AGC), the IF signals are sent to the
BBU for further processing.
Issue 04 (2011-02-15)
4-45
BTS3900
Hardware Description
4 BTS3900 Components
Generates the CPRI clock, recovers the CPRI clock from loss of synchronization, and
detects alarms.
In addition, the DRFU of 900 MHz can be equipped with the Frequency Domain Reflectometer
(FDR) to implement the accurate VSWR test.
The modules inside the DRFU consist of the high-speed interface unit, signal processing unit,
power amplifier, and dual-duplexer unit. Figure 4-35 shows the logical structure of the DRFU.
Figure 4-35 Logical structure of the DRFU
Adapts and transfers the signals from the BBU to the signal processing unit.
Adapts and transfers the signals from the signal processing unit to the BBU.
The signal processing unit consists of two uplink RX channels and two downlink TX channels.
l
The PA amplifies the low-power RF signals that are received from the signal processing unit.
The dual-duplexer unit performs the following functions:
4-46
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
LEDs
There are six LEDs on the panel of the DRFU, indicating its operating status. Table 4-48
describes the status of the LEDs on the DRFU.
Table 4-48 Status of the LEDs on the DRFU
LED
Color
State
Meaning
RUN
Green
On
Off
On
Off
No alarm is generated.
On
On
Off
Steady green
Steady red
ALM
ACT
VSWR
CPRI0
Issue 04 (2011-02-15)
Red
Green
Red
Red/Green
4-47
BTS3900
Hardware Description
4 BTS3900 Components
LED
CPRI1
Color
Red/Green
State
Meaning
Off
Steady green
Steady red
Off
Ports
Table 4-49 describes the ports and sockets on the DRFU.
Table 4-49 Ports and sockets on the DRFU
Port
Connector
Label
Description
Port for
transceiving
RF signals
DIN female
ANT1
CPRI port
SFP female
Interconnecti
on port for
receiving RF
signals
ANT2
QMA female
CPRI0
CPRI1
RX1/IN
RX1/OUT
RX2/IN
RX2/OUT
Power supply
socket
3V3
PWR
QMA
QMA female
FIXED
UNCOMB
COMB
4-48
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
4.4 WRFU
One WCDMA Radio Filter Unit (WRFU) supports 2 carriers or 4 carriers.
Panel
Figure 4-36 shows the panel of the WRFU.
Figure 4-36 Panel of the WRFU
Functions
The functions of the WRFU are as follows:
l
Issue 04 (2011-02-15)
Implements the direct frequency conversion technique in the transmit channel. The
baseband signals are modulated to WCDMA RF signals. After being filtered and amplified
or being combined, the RF signals are transmitted through the duplex filter to the antenna
for radio transmission.
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
4-49
BTS3900
Hardware Description
4 BTS3900 Components
Receives UL RF signals from the antenna system and then down-converts the received
signals to IF signals. After amplification, analog-to-digital conversion, digital downconversion, matched filtering, automatic gain control (AGC), the IF signals are sent to the
BBU for further processing.
Implements power control and Voltage Standing Wave Ratio (VSWR) detection
Generates the CPRI clock, recovers the CPRI clock from loss of synchronization, and
detects alarms
Principle
The WRFU consists of the high-speed interface unit, signal processing unit, power amplifier,
and duplex unit. Figure 4-37 shows the principle of the WRFU.
Figure 4-37 Principle of the WRFU
Transmits the signals received from the BBU to the signal processing unit
Transmits the signals received from the signal processing unit to the BBU
The signal processing unit consists of two UL RX channels and one DL TX channel.
l
4-50
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
LEDs
Table 4-50 describes the LEDs on the WRFU panel.
Table 4-50 LEDs on the MRFU panel
Label
RUN
ALM
ACT
VSWR
Issue 04 (2011-02-15)
Color
Green
Red
Green
Red
State
Description
ON
OFF
ON
OFF
No alarm is generated.
ON
ON (red)
4-51
BTS3900
Hardware Description
4 BTS3900 Components
Label
CPRI0
CPRI1
Color
Red/Green
Red/Green
State
Description
OFF (red)
On (green)
On (red)
OFF
On (green)
On (red)
OFF
Ports
Table 4-51 describes the ports on the WRFU panel.
Table 4-51 Ports on the WRFU panel
Port
Label
Connector
Description
RF port
ANT_RXB
DIN
ANT_TX/
RXA
DIN
CPRI0
SFP female
CPRI1
SFP female
Interconnectio
n port for RF
RX signals
RX_INB
QMA female
RX_OUTA
QMA female
Power supply
socket
PWR
2V2 power
Feeding power
CPRI
4-52
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Port
Label
Connector
Description
Commissionin
g port
MON
RJ-45
4.5 MRFU
One Multi-Mode Radio Frequency Unit (MRFU) supports a maximum of six carriers.
Panel
Figure 4-38 shows the panel of the MRFU.
Figure 4-38 Panel of the MRFU
Functions
The MRFU has the following functions:
Issue 04 (2011-02-15)
4-53
BTS3900
Hardware Description
4 BTS3900 Components
Modulates and converts the signals to the TX band by up-converting the IF signals, filters
and amplifies the signals, and then transmits the signals to the antenna through the duplexer
Generates the CPRI clock, recovers the CPRI clock from loss of synchronization, and
detects alarms
Principle
The MRFU consists of the high-speed interface unit, signal processing unit, power amplifier,
and duplex unit. Figure 4-39 shows the logical structure of the MRFU.
Figure 4-39 Logical structure of the MRFU
Transmits the signals received from the BBU to the signal processing unit
Transmits the signals received from the signal processing unit to the BBU
The signal processing unit consists of two uplink RX channels and one downlink TX channel.
l
4-54
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Encapsulate data
l
The power amplifier amplifies the low-power RF signals from the signal processing unit.
The duplexer has the following functions:
l
Combines the RX signals and TX signals so that they share the same antenna channel
LEDs
Table 4-52 describes the LEDs on the panel of the MRFU.
Table 4-52 LEDs on the panel of the MRFU
Label
RUN
ALM
ACT
VSWR
Issue 04 (2011-02-15)
Color
Green
Red
Green
Red
Status
Description
On
Off
On
Off
No alarm is generated.
On
On (red)
4-55
BTS3900
Hardware Description
4 BTS3900 Components
Label
CPRI0
CPRI1
Color
Red/Green
Red/Green
Status
Description
Off (red)
On (green)
On (red)
Off
On (green)
On (red)
Off
Ports
Table 4-53 describes the ports on the panel of the MRFU.
Table 4-53 Ports on the panel of the MRFU
Port
Label
RF Port
CPRI interface
Inter-MRFU
RF signal port
4-56
Connector
Function
ANT_RXB
DIN
connector
ANT_TX/
RXA
DIN
connector
CPRI0
SFP female
connector
CPRI1
SFP female
connector
RX_INB
QMA female
connector
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Port
Label
Connector
Function
RX_OUTA
QMA female
connector
Power supply
socket
PWR
3V3 power
connector
Monitoring
ports
MON
RJ-45
connector
4.6 LRFU
LTE Radio Frequency Units (LRFUs) work in Frequency Division Duplex (FDD) mode.
Panel
Figure 4-40 shows the panel of the LRFU.
Figure 4-40 Panel of the LRFU
Issue 04 (2011-02-15)
4-57
BTS3900
Hardware Description
4 BTS3900 Components
Functions
The LRFU processes uplink and downlink services and controls and monitors internal boards
or modules. Figure 4-41 shows the logical structure of the LRFU.
Figure 4-41 Logical structure of the LRFU
Filters and amplifies two uplink signals and performs digital down-conversion, analog-todigital (A/D) conversion, digital Inphase Quadrature (IQ) signal demodulation, and
matched filtering.
Performs uplink Automatic Gain Control (AGC) and stabilizes the level in the IQ digital
domain of the BBU-RFU interface.
4-58
Provides the functions of the Remote Electrical antenna Tilt (RET) antenna.
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Provides the BBU-RFU port for signal transmission by using the CPRI electrical cable or
optical cable.
LEDs
Table 4-54 describes the LEDs on the panel of the LRFU.
Table 4-54 LEDs on the LRFU
Label
RUN
ALM
ACT
VSWR
CPRI0
Issue 04 (2011-02-15)
Color
Green
Red
Green
Red
Red/Green
Status
Description
On
Off
On
Off
No alarm is generated.
On
On (red)
Off (red)
On (green)
On (red)
4-59
BTS3900
Hardware Description
4 BTS3900 Components
Label
CPRI1
Color
Red/Green
Status
Description
Off
On (green)
On (red)
Off
Port
Table 4-55 describes the ports on the panel of the LRFU.
Table 4-55 Ports on the panel of the LRFU
Label
Connector
Description
ANT_TX/RXB
DIN
ANT_TX/RXA
DIN
CPRI0
SFP female
connector
CPRI port
SFP female
connector
CPRI port
3V3 power
connector
Power port
RJ-45 connector
Monitoring port
CPRI1
PWR
MON
4.7 DCDU-01
The Direct Current Distribution Unit-01 (DCDU-01) supplies DC power to each component in
the cabinet.
4-60
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Panel
Figure 4-42 shows the panel of the DCDU-01.
Figure 4-42 Panel of the DCDU-01
Functions
The DCDU-01 has the following functions:
l
Supplies power to only the BBU3900, RFUs, and fan box in the cabinet, but not external
devices
Ports
Table 4-56 describes the ports, terminals, and power switches on the panel of the DCDU-01.
Table 4-56 Ports, terminals, and power switches on the panel of the DCDU-01
Issue 04 (2011-02-15)
Port
Label
Connector
Description
Power input
wiring
terminals
NEG(-)
OT terminal
Power output
port
SPARE2, SPARE1,
BBU, FAN, and
RFU5 to RFU0
Parallel terminal
Providing 10 power
outputs to the modules
such as the BBU3900,
RFUs, and fan box
Power switch
SPARE2, SPARE1,
BBU, FAN, and
RFU5 to RFU0
Powering on or powering
off the modules such as
the BBU3900, RFUs, and
fan box
RTN(+)
4-61
BTS3900
Hardware Description
4 BTS3900 Components
(1) Fan
(3) FMU
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Color
Status
Meaning
RUN
Green
Off
Off
No alarm is generated.
ALM
Red
Label
Connector
Type
Description
Power port
-48 V
3V3 power
connector
Sensor port
SENSOR
RJ-45 connector
Communicatio
n port
COM OUT
RJ-45 connector
COM IN
RJ-45 connector
4.9 GATM
The GSM Antenna and TMA control Module (GATM) controls the antenna and TMA.
Panel
Figure 4-45 shows the GATM panel.
Figure 4-45 GATM panel
Issue 04 (2011-02-15)
4-63
BTS3900
Hardware Description
4 BTS3900 Components
Function
The GATM has the following functions:
l
The GATM cannot support the TMA and RET antenna simultaneously.
LED
On the GATM there are three LEDs, which indicate the operating status of the GATM. Table
4-59 describes the LEDs on the GATM.
Table 4-59 LEDs on the GATM
LED
Color
Status
Description
RUN
Green
OFF
ON
OFF
Blinking irregularly
ON
OFF
ACT
ALM
Green
Red
Port ID
There are eight ports on the GATM, of which six are used to supply power to the TMA or transmit
the RET control signals, one is used to connect the GATM to the BBU, and one is used as an
extended RS485 port. In addition, there is also a -48 V DC power supply socket. Table 4-60
describes the ports and socket on the GATM.
4-64
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Connector
Function
ANT0 to ANT5
COM1
RJ-45 connector
COM2
RJ-45 connector
-48 V
4.10 ELU
The Electronic Label Unit (ELU) reports the cabinet type information to the fan box.
Figure 4-46 shows an ELU.
Figure 4-46 ELU
4-65
BTS3900
Hardware Description
4 BTS3900 Components
Description
PSU (DC/DC)
Panel
Figure 4-48 shows the panel of the PSU (DC/DC).
4-66
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Functions
l
Converts +24 V DC power into -48 V DC power and leads the -48 V DC power into the
DCDU-01.
Monitors the unit and reports alarms related to PSU faults (such as output overvoltage, no
output, and fan faults), alarms related to PSU protection (such as overtemperature
protection, and input overvoltage/undervoltage protection), and PSU out-of-position
alarms, if any.
LEDs
Table 4-62 describes the LEDs on the panel of the PSU (DC/DC).
Table 4-62 LEDs on the panel of the PSU (DC/DC)
LED
Color
Status
Description
Power LED
Green
On
Off
There is no power
input, or the fuse is
damaged.
Off
Protection LED
Issue 04 (2011-02-15)
Yellow
4-67
BTS3900
Hardware Description
4 BTS3900 Components
LED
Color
Fault LED
Red
Status
Description
On
There is abnormal
input or output
voltage, the unit is
overheated, or the
unit is not properly
inserted.
Off
Blinking
Exterior
Figure 4-49 shows the power subrack (DC/DC).
Figure 4-49 Power Subrack (DC/DC)
Ports
Table 4-63 describes the ports and terminals on the power subrack (DC/DC).
4-68
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Label
Connector
Description
Power input
wiring terminal
DC INPUT
OT terminal
Power output
wiring terminal
DC
OUTPUT
OT terminal
Alarm signal
port
ALM
Cord end
terminal
PRESENT port
PRESENT
RJ-45
connector
Issue 04 (2011-02-15)
4-69
BTS3900
Hardware Description
4 BTS3900 Components
(1) PMU
Description
PMU
PSU (AC/DC)
4.12.2 PMU
The Power and Environment Monitoring Unit (PMU) performs the power system management,
power distribution detection, and alarm reporting functions.
Exterior
Figure 4-51 shows the PMU.
Figure 4-51 PMU
4-70
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
Functions
The PMU performs the following functions:
l
Communicates with the BBU or upper-level PMU through an RS232/RS422 serial port.
Detects and reports water damage alarms, smoke alarms, door status alarms, and
customized Boolean values.
Reports the ambient temperature, ambient humidity, battery temperature, and customized
analog values.
Monitors power distribution, reports related alarms, and reports dry contact alarms.
(2) LEDs
Issue 04 (2011-02-15)
Port/Switch
Function
RS232/RS422 port
4-71
BTS3900
Hardware Description
4 BTS3900 Components
Port/Switch
Function
TEST port
Testing
COM port
Color
Status
Description
RUN
Green
On or off
On
ALM
Red
4-72
No alarm is reported.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
NOTE
In 3s to 5s after the PMU is powered on, the ALM and RUN LEDs are simultaneously on for about 3s.
DIP Switch
The DIP switch, which is used to choose monitoring address, is positioned on the right panel of
the PMU. The DIP switch has eight bits, which are set before the PMU is delivered, as shown
in Figure 4-53.
Figure 4-53 Right panel of the PMU
Panel
Figure 4-54 shows the panel of the PSU (AC/DC).
Issue 04 (2011-02-15)
4-73
BTS3900
Hardware Description
4 BTS3900 Components
Functions
The PSU (AC/DC) performs the following functions:
l
Converts 220 V AC power into -48 V DC power and supplies -48 V DC power to the
DCDU-01.
Monitors the unit and reports alarms related to PSU faults (such as output overvoltage, no
output, and fan faults), alarms related to PSU protection (such as overtemperature
protection, and input overvoltage/undervoltage protection), and PSU out-of-position alarm,
if any.
LEDs
Table 4-67 describes the LEDs on the panel of the PSU (AC/DC).
Table 4-67 LEDs on the panel of the PSU (AC/DC)
LED
Color
Status
Description
Power LED
Green
On
Off
Off
Protection LED
4-74
Yellow
Issue 04 (2011-02-15)
BTS3900
Hardware Description
4 BTS3900 Components
LED
Fault LED
Color
Red
Status
Description
On
There is a pre-alarm
relating to
temperature or the
fan.
Off
On
There is no output
because of output
overvoltage
shutdown, the fan
fault,
overtemperature
shutdown, remote
shutdown, or an
internal PSU fault.
Panel
Figure 4-55 shows the panel of the power subrack (AC/DC).
Issue 04 (2011-02-15)
4-75
BTS3900
Hardware Description
4 BTS3900 Components
Ports
Table 4-68 describes the terminals and switch on the power subrack (AC/DC).
Table 4-68 Terminals and switch on the power subrack (AC/DC)
4-76
Terminal/Switch
Description
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
BTS3900 Cables
The colors of cables vary according to the countries and areas where Huawei products are delivered. If
cables are purchased at local market, the colors of the cables must comply with the rules and regulations.
Issue 04 (2011-02-15)
5-1
BTS3900
Hardware Description
5 BTS3900 Cables
The BTS3900 signal cables are the monitoring signal cable for the DCDU, monitoring signal
cable for the PMU, monitoring signal cable for the PSU, in-position signal cable for the PSU,
monitoring signal cable for the FAN unit, BBU alarm cable, and GPS clock signal cable.
5.9 BTS3900 RF Cable
The BTS3900 RF cables are the RF jumper and inter-RFU RF signal cable.
5-2
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Cables to be
installed on
site
Cable
One End
Connector
Installatio
n Position
Connector
Installatio
n Position
OT terminal
The main
PGND
terminal
inside the
cabinet
OT terminal
External
grounding
bar
5.4
Equipotenti
al Cable
OT terminal
Wiring
terminal for
the
equipotential
cable
OT terminal
Wiring
terminal for
the
equipotential
cable
5.5.1 Input
Power
Cable for
the Cabinet
OT terminal
NEG(-) and
RTN(+) on
the
DCDU-01
OT terminal
External
power
supply
device
OT terminal
Power input
wiring
terminals of
the power
subrack
(DC/DC)
OT terminal
External
power
supply
device
OT terminal
Power input
wiring
terminals of
the power
subrack
(AC/DC)
OT terminal
External
power
supply
device
5.3 PGND
Cables
(PGND
cable for the
cabinet)
(-48 V power
cable)
5.5.1 Input
Power
Cable for
the Cabinet
(+24 V
power cable)
5.5.1 Input
Power
Cable for
the Cabinet
(AC power
cable)
Issue 04 (2011-02-15)
5-3
BTS3900
Hardware Description
5 BTS3900 Cables
Item
Cables
installed
before
delivery
Cable
One End
Connector
Installatio
n Position
Connector
Installatio
n Position
OT terminal
PGND
terminals of
the modules
OT terminal
PGND
terminals
inside the
cabinet.
5.5.5 Power
Cable for
the RFU
3V3 power
connector
PWR port on
the RFU
Parallel
terminal
Ports RFU0
to RFU5 on
the
DCDU-01
5.5.4 Power
Cable for
the Fan Box
3V3 power
connector
-48 V port of
the fan box
Parallel
terminal
FAN port on
the
DCDU-01
5.5.3 Power
Cable for
the BBU
3V3 power
connector
PWR port on
the UPEU
Parallel
terminal
BBU port on
the
DCDU-01
5.5.2 Power
Cable for
the
DCDU-01
OT terminal
RTN(+) port
on the
DCDU-01
OT terminal
RTN(+)
wiring
terminal for
power output
of the power
subrack
(DC/DC)
OT terminal
NEG(-) port
on the
DCDU-01
OT terminal
LOAD(-)
wiring
terminal for
power output
of the power
subrack
(DC/DC)
OT terminal
RTN(+) port
on the
DCDU-01
OT terminal
RTN(+)
wiring
terminal for
power output
of the power
subrack
(AC/DC)
5.3 PGND
Cables
(PGND
cable for the
modules)
(Black)
5.5.2 Power
Cable for
the
DCDU-01
(Blue)
5.5.2 Power
Cable for
the
DCDU-01
(Black)
5-4
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Item
Cable
5.5.2 Power
Cable for
the
DCDU-01
One End
Connector
Installatio
n Position
Connector
Installatio
n Position
OT terminal
NEG(-) port
on the
DCDU-01
OT terminal
LOAD1(-)
or LOAD2
(-) wiring
terminal for
power output
of the power
subrack
(AC/DC)
(Blue)
Transmission Cables
Table 5-2 lists the transmission cables.
Table 5-2 Transmission Cables
Item
Cables to be
installed on
site
Cable
One End
Connector
Installatio
n Position
Connector
Installatio
n Position
5.6.1 E1/T1
Cable
DB26 male
connector
E1/T1 port
on the
GTMU or
WMPT or
UTRP
None
External
transmission
equipment
5.6.2 FE/GE
Cable
RJ-45
FE0 or FE1
port on the
GTMU or
WMPT or
LMPT or
UTRP
RJ-45
External
transmission
equipment
5.6.3 FE/GE
Optical
Cable
LC
connector
SFP0 or
SFP1 port on
the GTMU
or WMPT or
UTRP
l FC
connecto
r
External
transmission
equipment
l SC
connecto
r
l LC
connecto
r
Issue 04 (2011-02-15)
5-5
BTS3900
Hardware Description
5 BTS3900 Cables
Item
Cables
installed
before
delivery
Cable
One End
Connector
Installatio
n Position
Connector
Installatio
n Position
5.6.4 Cable
Between
Two FE
Electrical
Ports
RJ-45
FE0 port on
the GTMU
RJ-45
FE0 port on
the WMPT
5.6.5 Cable
Between
Two FE
Optical
Ports
LC
connector
FE1 port on
the GTMU
LC
connector
FE1 port on
the WMPT
CPRI Cables
Table 5-3 lists the CPRI Cables.
Table 5-3 CPRI Cables
Item
Cable
One End
Connector
Installatio
n Position
Connector
Installatio
n Position
SFP200 male
connector
CPRI ports
on the
GTMU or
WBBP or
LBBP
SFP200 male
connector
CPRI ports
on the RFU
Cables
installed
before
delivery
5.7 CPRI
Electrical
Cable
Cables to be
installed on
site
The BTS3900 cabinet is delivered with boards installed, and the CPRI cables
in the cabinet are already installed. The CPRI cables between multiple
cabinets may be need to be installed on site according to the configuration.
Signal Cables
Table 5-4 lists the signal cables.
5-6
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Cables to be
installed on
site
Cables
installed
before
delivery
Issue 04 (2011-02-15)
Cable
One End
Connector
Installatio
n Position
Connector
Installatio
n Position
5.8.6
Monitoring
Signal
Cable for
the EMU
RJ-45
connector
RS485 port
on the EMU
RJ-45
connector
MON1 port
on the UPEU
or UEIU
5.8.8 BBU
Alarm
Cable
RJ-45
connector
EXT-ALM0
port on the
UPEU or
UEIU
RJ-45
connector
External
alarm device
5.8.9 GPS
Clock
Signal
Cable
SMA male
connector
GPS port on
the USCU
N-type
female
connector
GPS surge
protector
5.8.1
Monitoring
Signal
Cable for
the PMU
RJ-45
connector
Left RS232/
RS422 port
on PMU
RJ-45
connector
MON1 port
on the UPEU
5.8.2
Monitoring
Signal
Cable for
the PSU
(DC/DC)
RJ-45
connector
ALM port on
the power
subrack (DC/
DC)
Cord end
terminal
EXT-ALM0
port on the
UPEU
5.8.3 InPosition
Signal
Cable for
the PSU
(DC/DC)
RJ-45
connector
PRESENT
port on the
power
subrack (DC/
DC)
RJ-45
connector
EXT-ALM1
port on the
UPEU or
UEIU
5.8.4
Monitoring
Signal
Cable for
the Fan Box
RJ-45
connector
COM IN
port on the
fan box
RJ-45
connector
MON0 port
on the UPEU
5-7
BTS3900
Hardware Description
5 BTS3900 Cables
Item
Cable
One End
Connector
Installatio
n Position
Connector
Installatio
n Position
5.8.5 Fan
Box
Cascade
Signal
Cable
RJ-45
connector
COM OUT
port on the
upper-level
fan box
RJ-45
connector
COM IN
port on the
lower-level
fan box
5.8.10
Signal
Cable for
the ELU
RJ-45
connector
NOTE
Upper-level
fan box: the
fan box
directly
connected to
the BBU.
ELU
NOTE
Lower-level
fan box: the
fan box
connected to
the upperlevel fan box
and then to
the BBU.
RJ-45
connector
SENSOR on
the fan box
RF Cables
Table 5-5 lists the RF cables.
Table 5-5 RF Cables
Item
Cable
One End
Connector
Installatio
n Position
Connector
Installation
Position
Cables to be
installed on
site
5.9.1 RF
Jumper
DIN elbow
male
connector
RF ports on
the RFU
DIN straight
male
connector
Antenna
system
Cables
installed
before
delivery
5.9.2 InterRFU RF
Signal
Cable
QMA elbow
male
connector
RX OUT
port on one
RFU panel
QMA elbow
male
connector
RX IN port
on another
RFU panel
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Table 5-6 lists the power cables of the BTS3900 (-48 V).
Issue 04 (2011-02-15)
5-9
BTS3900
Hardware Description
5 BTS3900 Cables
Description
P1 to P6
P7
For details, see 5.5.4 Power Cable for the Fan Box.
P8
P11, P12
For details, see 5.5.1 Input Power Cable for the Cabinet.
Table 5-7 lists the power cables of the BTS3900 (+24 V).
Table 5-7 Power cables of the BTS3900 (+24 V)
5-10
SN
Description
P1 to P6
P7
For details, see 5.5.4 Power Cable for the Fan Box.
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
SN
Description
P8
P11, P12
P25 to P28
For details, see 5.5.1 Input Power Cable for the Cabinet.
Table 5-8 lists the power cables of the BTS3900 (220 V).
Table 5-8 Power cables of the BTS3900 (220 V)
Issue 04 (2011-02-15)
SN
Description
P1 to P6
5-11
BTS3900
Hardware Description
5 BTS3900 Cables
SN
Description
P7
For details, see 5.5.4 Power Cable for the Fan Box.
P8
P11, P12
L, N
For details, see 5.5.1 Input Power Cable for the Cabinet.
Cable Description
T1
Figure 5-5 shows the transmission cable connections when the E1/T1 cable is used for data
transmission in a GSM only base station where the GTMU and UTRP4 are configured as
transmission boards in the BBU3900.
Figure 5-5 E1/T1 cable connections
5-12
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Cable Description
T1 and T2
Cable Description
T1
Figure 5-7 shows the transmission cable connections when the FE/GE optical cable is used for
data transmission.
Figure 5-7 FE/GE optical cable connections
Issue 04 (2011-02-15)
Cable Number
Cable Description
T1
5-13
BTS3900
Hardware Description
5 BTS3900 Cables
Cable Description
T1
Figure 5-9 shows the transmission cable connections when only the E1/T1 cable is used for data
transmission in a base station where only the WMPT and UTRP3/UTRP4 is configured in the
BBU.
Figure 5-9 E1/T1 cable connections (2)
5-14
Cable Number
Cable Description
T1 and T2
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Cable Description
T1
Figure 5-11 shows the transmission cable connections when only the FE/GE Ethernet cable is
used for data transmission in a base station where only the WMPT and UTRP9 is configured in
the BBU.
Figure 5-11 FE/GE Ethernet cable connections (2)
Cable Description
T1 and T2
Figure 5-12 shows the transmission cable connections when only the FE/GE optical cable is
used for data transmission in a base station where only the WMPT is configured in the BBU.
Figure 5-12 FE/GE optical cable connections (1)
Issue 04 (2011-02-15)
5-15
BTS3900
Hardware Description
5 BTS3900 Cables
Cable Description
T1
Figure 5-13 shows the transmission cable connections when only the FE/GE optical cable is
used for data transmission in a base station where only the WMPT and UTRP2 is configured in
the BBU.
Figure 5-13 FE/GE optical cable connections (2)
Cable Description
T1 and T2
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Cable Description
T1 and T2
Cable Description
T1
Issue 04 (2011-02-15)
5-17
BTS3900
Hardware Description
5 BTS3900 Cables
Description
T1
Figure 5-17 shows the transmission cable connection for a GSM+UMTS base station in TDM
common transmission mode when the E1/T1 port on the GSM UTRP serves as the shared port
to connect to the BSC and RNC. The GSM UTRP communicates with the WMPT using the
backplane to implement TDM common transmission.
NOTE
Note that the E1/T1 ports on the GTMU and the WMPT can also be used for data transmission independently,
but the corresponding cable connections are not shown here.
Figure 5-17 Transmission cable connection for a GSM+UMTS base station in TDM common
transmission mode (2)
Description
T1
IP common transmission can also be implemented by interconnecting the FE/GE optical ports on the GTMU
and the WMPT. The transmission cable connections are similar to Figure 5-18, which are not described here.
Figure 5-18 Transmission cable connections for a GSM+UMTS base station in IP over E1
common transmission mode (1)
5-18
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Description
T1
T2
Figure 5-19 shows the transmission cable connections for a GSM+UMTS base station in IP
common transmission mode when the FE/GE electrical port on the WMPT serves as the shared
port to connect to the BSC and RNC, and the FE/GE optical ports on the GTMU and the WMPT
are interconnected to implement IP common transmission.
Figure 5-19 Transmission cable connections for a GSM+UMTS base station in IP over E1
common transmission mode (2)
Description
T1
T2
Issue 04 (2011-02-15)
5-19
BTS3900
Hardware Description
5 BTS3900 Cables
Description
T1
T2
Figure 5-21 shows the transmission cable connections for a GSM+UMTS base station in IP cotransmission mode when the WMPT FE/GE optical port is used as the shared port for data
transmission, and the FE/GE electrical ports of the GTMU and the WMPT are interconnected
to implement IP co-transmission.
Figure 5-21 Transmission cable connections for a GSM+UMTS base station in IP over FE
common transmission mode (2)
Description
T1
T2
5-20
IP transmission is applied. The GTMU and WMPT are connected to the BSC and RNC
respectively using the active channel.
The GTMU and the WMPT are interconnected using FE ports on their panels.
If the active channel is faulty, the standby channel takes over. After the active channel is
restored, the route is switched back to the active one.
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
The bandwidth required by UMTS services is larger than the processing capability of the
GSM standard transport network. Therefore, when the standby channel is used, the Quality
of Service (QoS) of only high-priority data flows can be guaranteed.
In a GSM+UMTS base station, the route backup mode with IP common transmission has the
following limitations:
l
The route backup function is not applicable when the base station uses the IP over E1
common transmission.
The route backup mode is not applicable to the ports on the UTRPs for GSM or UMTS
transmission. It is applicable only to the ports on the GTMU and WMPT panels.
In route backup mode, the FE ports of one type on the GTMU and WMPT panels are
interconnected. The FE ports of the other type on the two boards are connected to the BSC
and the RNC.
Figure 5-22 shows the transmission cable connections for a GSM+UMTS base station in route
backup mode with IP common transmission when the FE optical ports on the GTMU and WMPT
are interconnected and the FE electrical ports on the two boards are connected to the BSC and
RNC.
Figure 5-22 Transmission cable connections with FE optical ports for interconnection and FE
electrical ports connected to the BSC and RNC
Description
T1 and T2
T3
Figure 5-23 shows the transmission cable connections for a GSM+UMTS base station in route
backup mode with IP common transmission when the FE electrical ports on the GTMU and
WMPT are interconnected and the FE optical ports on the two boards are connected to the BSC
and RNC.
Figure 5-23 Transmission cable connections with FE electrical ports for interconnection and
FE optical ports connected to the BSC and RNC
Issue 04 (2011-02-15)
5-21
BTS3900
Hardware Description
5 BTS3900 Cables
Description
T1 and T2
T3
Cable Description
T1 and T2
5-22
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Cable Description
T1 and T2
Figure 5-26 shows the transmission cable connections when the FE/GE optical cables are used
for data transmission on both the GSM and UMTS sides when a GSM+UMTS base station works
in separate transmission mode.
Figure 5-26 FE/GE cable connections in separate transmission mode (2)
Cable Description
T1 and T2
Issue 04 (2011-02-15)
5-23
BTS3900
Hardware Description
5 BTS3900 Cables
Description
T1 and T2
T3
Figure 5-28 shows the transmission cable connections for a GSM+LTE base station when the
E1/T1 port on the LTE UTRP is connected to the transmission equipment and the FE/GE
electrical port on the LMPT is interconnected to the FE/GE electrical port on the GTMU.
Figure 5-28 Transmission cable connections for a GSM+LTE base station in IP over E1 common
transmission mode (2)
Description
T1 and T2
T3
5-24
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Description
T1
T2
Figure 5-30 shows the transmission cable connections for a GSM+LTE base station when the
FE/GE electrical port on the LMPT is connected to the transmission equipment and the FE/GE
optical port on the LMPT is interconnected to the FE/GE optical port on the GTMU.
Figure 5-30 Transmission cable connections for a GSM+LTE base station in IP over FE/GE
common transmission mode
Description
T1
T2
IP transmission is applied. The GTMU and LMPT are connected to the transport network
through the primary channel.
The GTMU and the LMPT are interconnected through FE ports on their panels.
If the primary channel is faulty, the secondary channel takes over. After the primary channel
is restored, the route is switched back to the primary one.
Issue 04 (2011-02-15)
5-25
BTS3900
Hardware Description
5 BTS3900 Cables
The bandwidth required by LTE services is larger than the processing capability of the
GSM standard transport network. Therefore, when the secondary channel is used, the
Quality of Service (QoS) of only high-priority data flows can be guaranteed.
In a GSM+LTE base station, the following limitations on the route backup transmission mode
apply:
l
The route backup function is not applicable when the base station uses the IP over E1
transmission.
The route backup transmission mode is not applicable on the ports on the UTRPs for GSM
and LTE transmission. It is applicable only on the ports on the GTMU and LMPT panels.
In route backup transmission mode, the FE ports of one type on the GTMU and LMPT
panels are interconnected. The FE ports of the other type on the two boards are connected
to the transport network.
Figure 5-31 shows the transmission cable connections for a GSM+LTE base station in route
backup mode with IP common transmission when the FE electrical ports on the GTMU and
LMPT are interconnected and the FE optical ports on the two boards are connected to the base
station controller.
Figure 5-31 Transmission cable connections with FE electrical ports for interconnection and
FE optical ports connected to the base station controller
Description
T1 and T2
T3
FE Optical Ports for Interconnection and FE Electrical Ports Connected to the BSC
and RNC
Figure 5-32 shows the transmission cable connections for a GSM+LTE base station in route
backup mode with IP common transmission when the FE optical ports on the GTMU and LMPT
are interconnected and the FE electrical ports on the two boards are connected to the base station
controller.
Figure 5-32 Transmission cable connections with FE optical ports for interconnection and FE
electrical ports connected to the base station controller
5-26
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Description
T1 and T2
T3
Cable Description
T1
T2
Figure 5-34 shows the transmission cable connections for a GSM+LTE base station when the
E1/T1 port (providing four E1s/T1s) on the GTMU is used for data transmission on the GSM
side and the FE/GE optical port is used for data transmission on the LTE side.
Issue 04 (2011-02-15)
5-27
BTS3900
Hardware Description
5 BTS3900 Cables
Figure 5-34 Transmission cable connections in a base station in GSM 4E1/T1+LTE FE/GE
mode (2)
Cable Description
T1
T2
Figure 5-35 shows the transmission cable connections for a GSM+LTE base station when the
E1/T1 port (providing four E1s/T1s) on the GTMU and the E1/T1 port (providing four E1s/T1s)
on the UTRP are used for data transmission on the GSM side and the FE/GE electrical port is
used for data transmission on the LTE side.
Figure 5-35 Transmission cable connections in a base station in GSM 8E1/T1+LTE FE/GE
mode (1)
Cable Description
T1 and T2
T3
Figure 5-36 shows the transmission cable connections for a GSM+LTE base station when the
E1/T1 port (providing four E1s/T1s) on the GTMU and the E1/T1 port (providing four E1s/T1s)
on the UTRP are used for data transmission on the GSM side and the FE/GE optical port is used
for data transmission on the LTE side.
5-28
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Figure 5-36 Transmission cable connections in a base station in GSM 8E1/T1+LTE FE/GE
mode (2)
Cable Description
T1 and T2
T3
Cable Description
T1 and T2
Figure 5-38 shows the transmission cable connections for a GSM+LTE base station when the
FE/GE electrical port is used for data transmission on the GSM side and the FE/GE optical port
is used for data transmission on the LTE side.
Issue 04 (2011-02-15)
5-29
BTS3900
Hardware Description
5 BTS3900 Cables
Figure 5-38 Transmission cable connections in a base station in GSM FE/GE+LTE FE/GE mode
(2)
Cable Description
T1
T2
5-30
SN
Description
T1 and T2
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
SN
Description
T3
Figure 5-40 shows the transmission cable connections for a UMTS+LTE base station when the
E1/T1 port on the LTE UTRP is connected to the transmission equipment and the FE/GE
electrical port on the LMPT is interconnected to the FE/GE electrical port on the WMPT.
Figure 5-40 Transmission cable connections for a UMTS+LTE base station in IP over E1
common transmission mode (2)
Description
T1 and T2
T3
Issue 04 (2011-02-15)
5-31
BTS3900
Hardware Description
5 BTS3900 Cables
Table 5-46 Transmission cables for a UMTS+LTE base station in IP over FE/GE common
transmission mode (1)
SN
Description
T1
T2
Figure 5-42 shows the transmission cable connections for a UMTS+LTE base station when the
FE/GE electrical port on the LMPT is connected to the transmission equipment and the FE/GE
optical port on the LMPT is interconnected to the FE/GE optical port on the WMPT.
Figure 5-42 Transmission cable connections for a UMTS+LTE base station in IP over FE/GE
common transmission mode
Description
T1
T2
5-32
IP transmission is applied. The WMPT and LMPT are connected to the transport network
through the primary channel.
The WMPT and the LMPT are interconnected through FE ports on their panels.
If the primary channel is faulty, the secondary channel takes over. After the primary channel
is restored, the route is switched back to the primary one.
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
The bandwidth required by LTE services is larger than the processing capability of the
UMTS standard transport network. Therefore, when the secondary channel is used, the
Quality of Service (QoS) of only high-priority data flows can be guaranteed.
In a UMTS+LTE base station, the following limitations on the route backup transmission mode
apply:
l
The route backup function is not applicable when the base station uses the IP over E1
transmission.
The route backup transmission mode is not applicable on the ports on the UTRPs for UMTS
and LTE transmission. It is applicable only on the ports on the WMPT and LMPT panels.
In route backup transmission mode, the FE ports of one type on the WMPT and LMPT
panels are interconnected. The FE ports of the other type on the two boards are connected
to the transport network.
Figure 5-43 shows the transmission cable connections for a UMTS+LTE base station in route
backup mode with IP common transmission when the FE electrical ports on the WMPT and
LMPT are interconnected and the FE optical ports on the two boards are connected to the
transmission equipment.
Figure 5-43 Transmission cable connections for a UMTS+LTE base station in route backup
mode with IP common transmission (1)
Description
T1 and T2
T3
Figure 5-44 shows the transmission cable connections for a UMTS+LTE base station in route
backup mode with IP common transmission when the FE optical ports on the WMPT and LMPT
are interconnected and the FE electrical ports on the two boards are connected to the transmission
equipment.
Figure 5-44 Transmission cable connections for a UMTS+LTE base station in route backup
mode with IP common transmission (2)
Issue 04 (2011-02-15)
5-33
BTS3900
Hardware Description
5 BTS3900 Cables
Description
T1 and T2
T3
Hybrid Transmission
In hybrid transmission mode, the UMTS E1/T1 port and LTE FE/GE port serve as shared ports
to connect to the transmission equipment. The E1/T1 port is used to transmit the services with
high QoS requirements, such as CS services; and the FE/GE port is used to transmit the services
with low QoS requirements, such as PS services.
The UMTS E1/T1 port and the LTE FE/GE port are used for data transmission in a UMTS+LTE
base station in hybrid transmission mode. When the UMTS FE/GE port and the LTE FE/GE
port are used for data transmission, hybrid transmission is not applicable.
Figure 5-45 shows the transmission cable connections in hybrid transmission mode (UMTS E1/
T1 port + LTE FE/GE optical port).
Figure 5-45 Transmission cable connections in hybrid transmission mode (1)
Description
T1
T2
T3
Figure 5-46 shows the transmission cable connections in hybrid transmission mode (UMTS E1/
T1 port + LTE FE/GE electrical port).
5-34
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Description
T1
T2
T3
Issue 04 (2011-02-15)
Cable Number
Cable Description
T1
5-35
BTS3900
Hardware Description
5 BTS3900 Cables
Cable Number
Cable Description
T2
Figure 5-48 shows the transmission cable connections for a UMTS+LTE base station when the
E1/T1 port (providing four E1s/T1s) on the WMPT is used for data transmission on the UMTS
side and the FE/GE optical port is used for data transmission on the LTE side.
Figure 5-48 Transmission cable connections in a base station in UMTS 4E1/T1+LTE FE/GE
mode (2)
Cable Description
T1
T2
Figure 5-49 shows the transmission cable connections for a UMTS+LTE base station when the
E1/T1 port (providing eight E1s/T1s) on the UTRP3 or UTRP4 is used for data transmission on
the UMTS side and the FE/GE electrical port is used for data transmission on the LTE side.
Figure 5-49 Transmission cable connections in a base station in UMTS 8E1/T1+LTE FE/GE
mode (1)
5-36
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Table 5-54 Transmission cable connections in a base station in UMTS 8E1/T1+LTE FE/GE
mode (1)
Cable Number
Cable Description
T1 and T2
T3
Figure 5-50 shows the transmission cable connections for a UMTS+LTE base station when the
E1/T1 port (providing eight E1s/T1s) on the UTRP3 or UTRP4 is used for data transmission on
the UMTS side and the FE/GE optical port is used for data transmission on the LTE side.
Figure 5-50 Transmission cable connections in a base station in UMTS 8E1/T1+LTE FE/GE
mode (2)
Cable Description
T1 and T2
T3
5-37
BTS3900
Hardware Description
5 BTS3900 Cables
Table 5-56 Transmission cable connections in a base station in UMTS FE/GE+LTE FE/GE
mode (1)
Cable Number
Cable Description
T1 and T2
Figure 5-52 shows the transmission cable connections for a UMTS+LTE base station when the
FE/GE electrical port is used for data transmission on the UMTS side and the FE/GE optical
port is used for data transmission on the LTE side.
Figure 5-52 Transmission cable connections in a base station in UMTS FE/GE+LTE FE/GE
mode (2)
Cable Description
T1
T2
5-38
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Issue 04 (2011-02-15)
5-39
BTS3900
Hardware Description
5 BTS3900 Cables
When the WRFUs work in single-band mode and support not more than three sectors (two
WRFUs for each sector) in a base station with MIMO supported, or when the bandwidth and
carriers are expanded, the CPRI ports are connected in chain topology, as shown in Figure
5-56 and Figure 5-57.
Figure 5-56 Chain topology over CPRI ports
5-40
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Figure 5-59 shows the CPRI cable connections in the 3 x 20 MHz 2T2R configuration.
Issue 04 (2011-02-15)
5-41
BTS3900
Hardware Description
5 BTS3900 Cables
Figure 5-60 shows the CPRI cable connections in the 3 x 10 MHz 4T4R configuration.
Figure 5-60 CPRI cable connections in the 3 x 10 MHz 4T4R configuration
Figure 5-61 shows the CPRI cable connections in the 3 x 20 MHz 4T4R configuration.
5-42
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Issue 04 (2011-02-15)
5-43
BTS3900
Hardware Description
5 BTS3900 Cables
When the MRFUs work in single-band mode and support more than three sectors, the CPRI
ports are connected in dual-star topology, as shown in Figure 5-64 and Figure 5-65.
Figure 5-64 Dual-star topology over CPRI ports (3)
5-44
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Issue 04 (2011-02-15)
5-45
BTS3900
Hardware Description
5 BTS3900 Cables
Figure 5-67 CPRI cable connections in a co-cabinet base station with WRFUs and DRFUs/
GRFUs (2)
When the MRFUs work in dual-mode and support three sectors and when the WRFU support
three sectors in a base station with MIMO not supported, the CPRI cables are connected in the
manner shown in Figure 5-68.
5-46
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Figure 5-68 CPRI cable connections in a co-cabinet base station with MRFUs and WRFUs (1)
When the MRFUs work in dual-mode and support three sectors and when the WRFU support
three sectors in a base station with MIMO supported, the CPRI cables are connected in the
manner shown in Figure 5-69.
Figure 5-69 CPRI cable connections in a co-cabinet base station with MRFUs and WRFUs (2)
Issue 04 (2011-02-15)
5-47
BTS3900
Hardware Description
5 BTS3900 Cables
When the MRFUs work in dual-mode and support three sectors, and the number of DRFUs/
GRFUs is more than three, the UBRI is required. In this case, the CPRI cables are connected in
the manner shown in Figure 5-70.
Figure 5-70 CPRI cable connections in a co-cabinet base station with MRFUs and DRFUs/
GRFUs
5-48
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
5-49
BTS3900
Hardware Description
5 BTS3900 Cables
The WRFUs and LRFUs in a UMTS+LTE base station use the same CPRI cable connection as
the RFUs in a UMTS only base station and LTE only base station respectively, as shown in
Figure 5-73.
Figure 5-73 CPRI port connection principles
If any device is not configured at the site, neglect the device and its cable connection.
5-50
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Figure 5-74 Monitoring signal cable connections of the BTS3900 (-48 V DC)
Table 5-58 Monitoring signal cable connections of the BTS3900 (-48 V DC)
Cable Number
Cable Description
S1 and S2
S3
S4
S5
S6 and S7
Issue 04 (2011-02-15)
5-51
BTS3900
Hardware Description
5 BTS3900 Cables
Figure 5-75 Monitoring signal cable connections of the BTS3900 (+24 V DC)
Table 5-59 Monitoring signal cable connections of the BTS3900 (+24 V DC)
5-52
Cable Number
Cable Description
S1 and S2
S3
S4
S5
S6 and S7
S8
S9 and S10
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Cable Description
S1 and S2
S3
S4
S5 and S6
S7
S8 and S9
5-53
BTS3900
Hardware Description
5 BTS3900 Cables
The following description is based on the RF cable connections for DRFUs with a single sector.
One DRFU
With one RX channel and two TX channels, the following items are configured for two carriers:
l
One DRFU
Two DRFUs
5-54
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
One DRFU
Two DRFUs
5-55
BTS3900
Hardware Description
5 BTS3900 Cables
One GRFU
Two GRFUs
5-56
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Three GRFUs
Issue 04 (2011-02-15)
5-57
BTS3900
Hardware Description
5 BTS3900 Cables
Four GRFUs
5-58
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
One WRFU
Issue 04 (2011-02-15)
5-59
BTS3900
Hardware Description
5 BTS3900 Cables
With one RX channel and two TX channels, the following items are configured for five to eight
carriers:
l
Two WRFUs
5-60
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Two WRFUs
Two WRFUs
Issue 04 (2011-02-15)
5-61
BTS3900
Hardware Description
5 BTS3900 Cables
A dual-polarized antenna
An LRFU
5-62
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Two LRFUs
Issue 04 (2011-02-15)
5-63
BTS3900
Hardware Description
5 BTS3900 Cables
One MRFU
5-64
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Two MRFUs
Issue 04 (2011-02-15)
5-65
BTS3900
Hardware Description
5 BTS3900 Cables
One MRFU
Two MRFUs
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
(1) OT terminal
(1) OT terminal
Structure
The equipotential cable is a single cable with OT terminals at both ends. It is a yellow and green
cable with cross-sectional area of 16 mm2. The OT terminals should be made on site.
Figure 5-92 show the equipotential cable.
Figure 5-92 Equipotential cable
(1) OT terminals
Issue 04 (2011-02-15)
5-67
BTS3900
Hardware Description
5 BTS3900 Cables
(1) OT terminal
5-68
Cable
Color
Cross-Sectional
Area
OT Aperture
Blue
16 mm2
M6
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Cable
Color
Cross-Sectional
Area
OT Aperture
Black
(1) OT terminal
Color
Cross-Sectional
Area
OT Aperture
Red
25 mm2
M6
Black
NOTE
The +24 V power cable consists of two pairs of wires, with each pair containing a red wire and a black
wire.
AC Power Cable
The BTS3900 cabinet supports three types of AC power supply. That is, the 220 V AC singlephase, 220 V AC three-phase, and 110 V AC dual-live-wire. The AC power cable feeds AC
power into a cabinet. Figure 5-95 shows the AC power cable. Table 5-63 describes the AC
power cable.
Issue 04 (2011-02-15)
5-69
BTS3900
Hardware Description
5 BTS3900 Cables
(1) OT terminal
NOTE
Different types of 220 V power cable have different exteriors and consist of different numbers of wires.
Figure 5-95 shows the 220 V AC single-phase power cable.
Wire
Cross-Sectional
Area
OT Aperture
L1 wire
2.5 mm2
M6
L2 wire
L3 wire
N wire
L wire
L1 wire
6 mm2
N wire
6 mm2
L2 wire
NOTE
The colors and exteriors of cables delivered by Huawei vary according to countries and areas. If cables are
purchased at local markets, the cables must comply with the local rules and regulations.
Exterior
Figure 5-96 shows the power cable for the DCDU-01.
5-70
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
(1) OT terminal
Cable Description
Table 5-64 describes the power cable for the DCDU-01.
Table 5-64 Power cable for the DCDU-01
Power Equipment
Cable Color
Cross-Sectional Area
OT Aperture
Power equipment
(DC/DC)
Blue
16 mm2
M6
Power equipment
(AC/DC)
Blue
16 mm2
M6
Black
Black
Exterior
Figure 5-97 shows the power cable for the BBU.
Figure 5-97 Power cable for the BBU
Issue 04 (2011-02-15)
5-71
BTS3900
Hardware Description
5 BTS3900 Cables
Pin Assignment
Table 5-65 describes the pin assignment of the power cable for the BBU.
Table 5-65 Pin assignment of the power cable for the BBU
Cable
X1 End
X2 End
Cable Color
W1
A3
B1
Black
W2
A1
B2
Blue
Exterior
Figure 5-98 shows the power cable for the fan box.
Figure 5-98 Power cable for the fan box
Pin Assignment
Table 5-66 describes the pin assignment for the wires of the power cable for the fan box.
Table 5-66 Pin assignment for the wires of the power cable for the fan box
Cable
X1 End
X2 End
Cable Color
W1
A3
B1
Black
W2
A1
B2
Blue
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Exterior
Figure 5-99 shows the power cable for the RFU.
Figure 5-99 Power cable for the RFU
Pin Assignment
Table 5-67 describes the pin assignment for the wires of the power cable for the RFU.
Table 5-67 Pin assignment for the wires of the power cable for the RFU
Cable
X1 End
X2 End
Cable Color
W1
A3
B1
Black
W2
A1
B2
Blue
Structure
One end of the power cable for the GATM is a parallel terminal, and the other end is a 3V3
power connector. Figure 5-100 shows the power cable for the GATM.
Issue 04 (2011-02-15)
5-73
BTS3900
Hardware Description
5 BTS3900 Cables
Pin Assignment
Table 5-68 describes the pin assignment for the wires of the power cable for the GATM.
Table 5-68 Pin assignment for the wires of the power cable for the GATM
Wire
X1 End
X2 End
Wire Color
W1
X1.A1
X2.B2
Blue
W2
X1.A3
X2.B1
Black
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Exterior
The E1/T1 cables are classified into two types: 75-ohm E1 coaxial cable and 120-ohm E1 twisted
pair cable.
One end of the E1/T1 cable is a DB26 male connector. The connector at the other end of the
cable should be made on site according to site requirements. Figure 5-101 shows an E1/T1 cable.
Figure 5-101 E1/T1 cable
One End
L9 male connector
L9 female connector
SMB female connector
BNC male connector
SMZ male connector
SMZ female connector
Pin Assignment
Table 5-70 and Table 5-71 describe the pin assignment for the wires of the E1/T1 cable.
Issue 04 (2011-02-15)
5-75
BTS3900
Hardware Description
5 BTS3900 Cables
NOTE
In Table 5-70, "Tip" refers to a wire in the E1 coaxial cable, and "Ring" refers to an external conductor of
the cable.
Table 5-70 Pin assignment for the wires of the 75-ohm E1 coaxial cable
Pins of the DB26
Male Connector
Wire Type
Cable Label
X1.1
Tip
RX1+
X1.2
Ring
X1.3
Tip
X1.4
Ring
X1.5
Tip
X1.6
Ring
X1.7
Tip
X1.8
Ring
X1.19
Tip
X1.20
Ring
X1.21
Tip
X1.22
Ring
X1.23
Tip
X1.24
Ring
X1.25
Tip
X1.26
Ring
RX13
RX2+
RX2-
RX3+
RX3-
RX4+
RX4-
TX1+
TX1-
TX2+
TX2-
TX3+
TX3-
TX4+
TX4-
Table 5-71 Pin assignment for the wires of the 120-ohm E1 twisted pair cable
5-76
Wire Color
Wire Type
Cable Labels
X.1
Blue
Twisted pair
RX1+
X.2
White
X.3
Orange
X.4
White
X.5
Green
X.6
White
RX1Twisted pair
RX2+
RX2-
Twisted pair
RX3+
RX3Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Wire Color
Wire Type
Cable Labels
X.7
Brown
Twisted pair
RX4+
X.8
White
X.19
Gray
X.20
White
X.21
Blue
X.22
Red
X.23
Orange
X.24
Red
X.25
Green
X.26
Red
RX4Twisted pair
TX1+
TX1-
Twisted pair
TX2+
TX2-
Twisted pair
TX3+
TX3-
Twisted pair
TX4+
TX4-
The maximum length of the FE/GE cable for remote connection is 100 m.
Exterior
The FE/GE cable is a shielded straight-through cable. It has an RJ-45 connector at each end, as
shown in Figure 5-102.
Figure 5-102 FE/GE cable
Pin Assignment
Table 5-72 describes the pin assignment for the wires of the FE/GE cable.
Issue 04 (2011-02-15)
5-77
BTS3900
Hardware Description
5 BTS3900 Cables
Table 5-72 Pin assignment for the wires of the FE/GE cable
Pin on the RJ-45
Connector
Wire Color
Wire Type
X1.2
Orange
Twisted pair
X2.2
X1.1
White and
orange
X1.6
Green
X1.3
White and
green
X1.4
Blue
X1.5
X1.8
Brown
X1.7
White and
brown
X2.1
Twisted pair
X2.6
X2.3
Twisted pair
X2.4
X2.5
Twisted pair
X2.8
X2.7
Exterior
The FE/GE optical cable has an LC connector at one end and an FC connector, SC connector,
or LC connector at the other end, as shown in Figure 5-103, Figure 5-104, and Figure 5-105
respectively.
Figure 5-103 FE/GE optical cable (FC and LC connectors)
5-78
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
CAUTION
When connecting the BBU3900 and the transmission device using the FE/GE optical cable,
adhere to the following rules:
l
The TX port on the BBU3900 is connected to the RX port on the transmission device.
The RX port on the BBU3900 is connected to the TX port on the transmission device.
Structure
The cable between two FE electrical ports has an RJ-45 connector at each end, as shown in
Figure 5-106.
Figure 5-106 Cable between two FE electrical ports
Structure
The cable between two FE optical ports has an LC connector at each end, as shown in Figure
5-107.
Issue 04 (2011-02-15)
5-79
BTS3900
Hardware Description
5 BTS3900 Cables
(1) LC connector
Exterior
The CPRI electrical cable is an SFP high speed transmission cable that has an SFP20 male
connector at each end, as shown in Figure 5-108.
Figure 5-108 CPRI electrical cable
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
The monitoring signal cable for the EMU transmits monitoring signals from the EMU to the
BBU.
5.8.7 Monitoring Signal Cable for the GATM
This cable connects the BBU and GATM, enabling the BBU to transmit control signals to the
GATM and enabling the GATM to report alarms to the BBU.
5.8.8 BBU Alarm Cable
The BBU alarm cable transmits alarm signals from an external alarm device to the BBU.
5.8.9 GPS Clock Signal Cable
The GPS clock signal cable is an optional cable that transmits GPS clock signals from the GPS
antenna system to the BBU. The GPS clock signals serve as the clock reference of the BBU.
5.8.10 Signal Cable for the ELU
The signal cable for the ELU is used to report the cabinet type information detected by the ELU
to the fan box.
Exterior
Figure 5-109 shows the monitoring signal cable for the PMU.
Figure 5-109 Monitoring signal cable for the PMU
Pin Assignment
Table 5-73 describes the pin assignment for the wires of the monitoring signal cable for the
PMU.
Table 5-73 Pin assignment for the wires of the monitoring signal cable for the PMU
Issue 04 (2011-02-15)
X1 End
X2 End
Wire Color
Wire Type
X1.1
X2.1
White
Twisted pair
X1.2
X2.2
Orange
X1.3
X2.3
White
X1.6
X2.6
Green
Twisted pair
5-81
BTS3900
Hardware Description
5 BTS3900 Cables
X1 End
X2 End
Wire Color
Wire Type
X1.5
X2.5
White
Twisted pair
X1.4
X2.4
Blue
X1.7
X2.7
White
X1.8
X2.8
Brown
Twisted pair
Exterior
The blue and white wires of the monitoring cable is used for monitoring the power status of the
PSUs. The other wires are tied to the column of the cabinet. Figure 5-110 shows the monitoring
signal cable for the PSU (DC/DC).
Figure 5-110 Monitoring signal cable for the PSU (DC/DC)
Exterior
Figure 5-111 shows the in-position signal cable for the PSU (DC/DC).
5-82
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Pin Assignment
Table 5-74 describes the pin assignment for the wires of the in-position signal cable for the PSU
(DC/DC).
Table 5-74 Pin assignment for the wires of the in-position signal cable for the PSU (DC/DC)
X1 End
X2 End
Wire Color
Wire Type
X1.1
X2.1
White
Twisted pair
X1.2
X2.2
Orange
X1.3
X2.3
White
X1.6
X2.6
Green
X1.5
X2.5
White
X1.4
X2.4
Blue
X1.7
X2.7
White
X1.8
X2.8
Brown
Twisted pair
Twisted pair
Twisted pair
Exterior
Figure 5-112 shows the monitoring signal cable for the fan box.
Issue 04 (2011-02-15)
5-83
BTS3900
Hardware Description
5 BTS3900 Cables
Pin Assignment
Table 5-75 describes the pin assignment for the wires of the monitoring signal cable for the fan
box.
Table 5-75 Pin assignment for the wires of the monitoring signal cable for the fan box
X1 End
X2 End
Color
Type
X1.1
X2.1
White
X1.2
X2.2
Orange
X1.3
X2.3
White
X1.6
X2.6
Green
X1.5
X2.5
White
X1.4
X2.4
Blue
X1.7
X2.7
White
X1.8
X2.8
Brown
Structure
Figure 5-113 shows the fan box cascade signal cable.
5-84
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Pin Assignment
Table 5-76 describes the pin assignment of the fan box cascade signal cable.
Table 5-76 Pin assignment of the fan box cascade signal cable
X1 End
X2 End
Color
Type
X1.1
X2.1
White
X1.2
X2.2
Orange
X1.3
X2.3
White
X1.6
X2.6
Green
X1.5
X2.5
White
X1.4
X2.4
Blue
X1.7
X2.7
White
X1.8
X2.8
Brown
Exterior
Figure 5-114 shows the monitoring signal cable for the EMU.
Issue 04 (2011-02-15)
5-85
BTS3900
Hardware Description
5 BTS3900 Cables
Pin Assignment
Table 5-77 describes the pin assignment for the wires of the monitoring signal cable for the
EMU.
Table 5-77 Pin assignment for the wires of the monitoring signal cable for the EMU
Pin on the
RJ-45
Connector
Wire Color
Wire Type
Label
X1.1
X2.3
White
Twisted pair
TX+
X1.2
X2.7
Orange
X1.5
X2.6
White
X1.4
X2.2
Blue
TXTwisted pair
RXRX+
Structure
Figure 5-115 shows the monitoring signal cable for the GATM.
5-86
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
Pin Assignment
Table 5-78 describes the pin assignment for the wires of the monitoring signal cable for the
GATM.
Table 5-78 Pin assignment for the wires of the monitoring signal cable for the GATM
X1 End
X2 End
Wire Color
Wire Type
X1.1
X2.1
White
Twisted pair
X1.2
X2.2
Orange
X1.3
X2.3
White
X1.6
X2.6
Green
X1.5
X2.5
White
X1.4
X2.4
Blue
X1.7
X2.7
White
X1.8
X2.8
Brown
Twisted pair
Twisted pair
Twisted pair
Exterior
The BBU alarm cable has an RJ-45 connector at each end, as shown in Figure 5-116. However,
an RJ-45 connector at one end may be removed, and an appropriate terminal may be added
according to the field requirements.
Issue 04 (2011-02-15)
5-87
BTS3900
Hardware Description
5 BTS3900 Cables
Pin Assignment
Table 5-79 describes the pin assignment for the wires of the BBU alarm cable.
Table 5-79 Pin assignment for the wires of the BBU alarm cable
BBU
Alarm
Port
Pin on the
RJ45
Connecto
r at One
End
Wire
Color
Wire
Type
Pin on the
RJ45
Connecto
r at the
Other
End
Description
EXTALM1
X1.1
White and
orange
Twisted
pair
X2.1
X1.2
Orange
X2.2
X1.3
White and
green
X2.3
X1.6
Green
X2.6
X1.5
White and
blue
X2.5
X1.4
Blue
X2.4
X1.7
White and
brown
X2.7
X1.8
Brown
X2.8
X1.1
White and
orange
X2.1
X1.2
Orange
X2.2
EXTALM0
5-88
Twisted
pair
Twisted
pair
Twisted
pair
Twisted
pair
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
BBU
Alarm
Port
Pin on the
RJ45
Connecto
r at One
End
Wire
Color
Wire
Type
Pin on the
RJ45
Connecto
r at the
Other
End
Description
X1.3
White and
green
Twisted
pair
X2.3
X1.6
Green
X2.6
X1.5
White and
blue
X2.5
X1.4
Blue
X2.4
X1.7
White and
brown
X2.7
X1.8
Brown
X2.8
Twisted
pair
Twisted
pair
Exterior
The GPS clock signal cable has an SMA male connector at one end and an N-type female
connector at the other end, as shown in Figure 5-117.
Figure 5-117 GPS clock signal cable
Issue 04 (2011-02-15)
5-89
BTS3900
Hardware Description
5 BTS3900 Cables
Exterior
Figure 5-118 shows the signal cable for the ELU.
Figure 5-118 Signal cable for the ELU
Pin Assignment
Table 5-80 describes the pin assignment for the wires of the signal cable for the ELU.
Table 5-80 Pin assignment for the wires of the signal cable for the ELU
X1 End
X2 End
Wire Color
Wire Type
X1.1
X2.1
White
Twisted pair
X1.2
X2.2
Orange
X1.3
X2.3
White
X1.6
X2.6
Green
X1.5
X2.5
White
X1.4
X2.4
Blue
X1.7
X2.7
White
X1.8
X2.8
Brown
Twisted pair
Twisted pair
Twisted pair
Issue 04 (2011-02-15)
BTS3900
Hardware Description
5 BTS3900 Cables
5.9.1 RF Jumper
The RF jumper connects the RFU and the feeder of the antenna system for signal exchange
between the base station and the antenna system.
Exterior
Figure 5-119 shows an RF jumper.
Figure 5-119 RF jumper
NOTE
Structure
Figure 5-120 shows the inter-RFU RF signal cable.
Figure 5-120 Inter-RFU RF signal cable
Issue 04 (2011-02-15)
5-91
BTS3900
Hardware Description
Issue 04 (2011-02-15)
6-1
BTS3900
Hardware Description
Table 6-1 lists the cables between the BTS3900 and the PS4890.
Table 6-1 Cables between the BTS3900 and the PS4890
SN
P1, P2
6-2
Cable
For details, see Output Power Cable for the
DCDU-04
Issue 04 (2011-02-15)
BTS3900
Hardware Description
SN
S1
Cable
For details, see 5.8.1 Monitoring Signal Cable for
the PMU
6.2 EMU
The Environment Monitoring Unit (EMU) is an environmental monitoring device that monitors
environmental conditions of the equipment room.
The EMU connects to main equipment and performs monitoring functions through the alarm
cables. The EMU performs the following functions:
l
Provides monitoring ports for the temperature, humidity, water, infrared, door control
sensors, Boolean signals, analog signals, and output control signals.
Provides the RS485 and RS232 ports for the communication with the base station.
For details about the structure and functions of the EMU, see HUAWEI QCKG1EMU User
Guide.
6.3 DDF
This section describes the structure, functions, features, and technical specifications of the DDF.
Structure
Figure 6-2 shows the structure of the DDF.
Figure 6-2 Structure of the DDF
Issue 04 (2011-02-15)
6-3
BTS3900
Hardware Description
Function
The DDF performs the following functions:
l
Transfers signals through the trunk cables between the communication devices and the
transmission devices.
Transfers signals through the alarm cables between the communication devices and the
external alarm devices.
Feature
The DDF has the following features:
l
Provides wall-mounting pieces and supporting the installations in a 19-inch cabinet and on
a wall.
Technical Specification
Table 6-2 describes the technical specifications of the DDF.
Table 6-2 Technical specifications of the DDF
6-4
Item
Specification
44 mm x 483 mm x 59 mm
Weight
1 kg
Working rate
2 Mbit/s
Characteristic impedance
120 ohms
60 dB
Insertion loss
0.4 dB
Return loss
18 dB
Issue 04 (2011-02-15)