REPUBLIC OF THE PHILIPPINES

PROVINCE OF ABRA

T A B L E O F
C O N T E N T

OFFICE OF THE BUILDING


OFFICIALS
MUNICIPALITY OF BANGUED

BUILDING OFFICIAL

CS - 1

PERSPECTIVE
SITE DEVELOPMENT PLAN
LOCATION PLAN
VICINITY MAP

A-1

LAND USE AND ZONING

FLOOR PLANS
ROOF PLAN
ELEVATIONS
SECTIONS

LINE AND GRADE

SCHEDULE OF DOORS AND WINDOWS

S-1

FOUNDATION PLAN
SECOND FLOOR FRAMING PLAN
ROOF FRAMING PLAN
SCHEDULE OF BEAMS,SLABS,FOOTINGS

ARCHITECTURAL

WALL FOOTING DETAILS


TYPICAL BEAM DETAILS
COLUMN DETAILS
TRUSS SCHEMATIC LAYOUTS
STRUCTURAL

E-1

GENERAL NOTES & LEGEND


ELECTRICAL LAYOUT PLANS
SCHEDULE OF LOADS
COMPUTATIONS
ELECTRICAL

PANEL BOARD DETAIL


RISER DIAGRAM
P-1

GENERAL NOTES & LEGEND


PLUMBING LAYOUT PLANS
PLUMBING

DETAIL OF SEPTIC TANK


DETAIL OF CATCH BASIN
ISOMETRIC LAYOUTPLAN

MECHANICAL

JUN MICHAEL A. VELASCO


D

#101 SAO-ATAN PROPER


BANGUED,ABRA

R.A. 545 :

ARCHITECT:

CP # : 09154462503

P.T.R. No. :

ISSUED ON :

R.E.G. No. :

ISSUED AT :

DRAWINGS AND SPECIFICATIONS DULY SIGNED,


STAMPED OR SEALED, AS INSTRUMENTS OF SERVICE,
ARE THE PROPERTY AND DOCUMENTS OF THE
ARCHITECT AND ENGINEER, WHETHER THE OBJECT
FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT
SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE
WRITTEN CONSENT OF THE ARCHITECT/ENGINEER, TO
DUPLICATE OR MAKE COPIES OF SAID DOCUMENTS
FOR USE IN THE REPETITION OF AND FOR OTHER
PROJECTS OR BUILDINGS, WHETHER EXECUTED
PARTLY OR IN WHOLE.

PROJECT TITLE:

OWNER:

SHT. NO.:

SHEET CONTENTS:

CS-1
DRAWN :

CHECKED :

DESIGNED :

DATE :

A-03

A-04

7.87 m.
SERVICE ENTRY

W
3

+200 mm

7.87 m.

2ND FLOOR LINE

2.65 m.

11

A-04

A-04

STREET LVL
00.00

4.25 m.

#101 SAO-ATAN PROPER


BANGUED,ABRA

CP # : 09154462503

P.T.R. No. :

ISSUED ON :

R.E.G. No. :

ISSUED AT :

A-04

A-2

R.A. 545 :

1:40m.

ARCHITECT:

W
1

W
1

3.25 m.

SCALE

JUN MICHAEL A. VELASCO


E

FIRST FLOOR PLAN

A-2

1
A-03

TABLE

DRAWINGS AND SPECIFICATIONS DULY SIGNED,


STAMPED OR SEALED, AS INSTRUMENTS OF SERVICE,
ARE THE PROPERTY AND DOCUMENTS OF THE
ARCHITECT AND ENGINEER, WHETHER THE OBJECT
FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT
SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE
WRITTEN CONSENT OF THE ARCHITECT/ENGINEER, TO
DUPLICATE OR MAKE COPIES OF SAID DOCUMENTS
FOR USE IN THE REPETITION OF AND FOR OTHER
PROJECTS OR BUILDINGS, WHETHER EXECUTED
PARTLY OR IN WHOLE.

1.00 m.

TABLE

0.75 m.

4.25 m.

+800 mm

2ND FLOOR LINE

G
STAIR LANDIN

1.00 m.

20.0
%

20.0

+100 mm

CORRIDOR LVL

GATE ENTRANCE
+200 mm

2.65 m.

COMPUTER SHOP

2.65 m.

+200 mm

D-1

ENTRANCE LVL

UP

+800 mm

G
STAIR LANDIN

+3200 mm

PROJECT TITLE:

TABLE

A-03

A-04

10

2.70 m.

TABLE

12

A-04

TABLE

1.08 m.

PERIMETER LINE

0.50 m.

14
13

TABLE

1.00 m.

A-04

1.55 m.

STO.

+3150 mm

TABLE

0.56 m.

A-03

DN

2.65 m.

CARPORT

+200 mm

13

1.04 m.

A-03

1.92 m.

14

TOILET FOR GIRLS

ENTRANCE
PERIMETER LINE

D-3

D-3

WASH ROOM
+3200 mm

W
2

+3150 mm

UNTER
D FLOOR CO

2.70 m.

PERIMETER LINE

PERIMETER LINE

COUNTER

+200 mm

TABLE

TOILET FOR BOYS

2N
+3200 mm

1.08 m.

REF.

CLOSET

D-3

W
3

W
3

KITCHEN AND SINK

+150 mm

1.75 m.

1.58 m.

D-2

A-03

A-04

2.91 m.

A-03

B
A

3.25 m.

1
A-03

STREET LVL
00.00

SECOND FLOOR PLAN

1:40m.

SCALE

OWNER:

SHT. NO.:

SHEET CONTENTS:

DRAWN :

CHECKED :

DESIGNED :

DATE :

2
A

GA. 26 PREPAINTED
RIDGE ROLL

GA. 26
PREPAINTED END
FLASHING

25mm x 300mm
FASCIA BOARD

PREPAINTED RIB TYPE LONG


SPAN ROOFING SHEET

GA. 24 SPANISH
TYPE GUTTER
(TYPICAL)

TOP OF ROOF BEAM

1.20 m.

1.20 m.

F
25mm x 300mm
FASCIA BOARD

C.H.B. WALL WITH CEMENT PLASTER FINISH


AND WATERPROOFING CEMENT BASE

GA. 24 SPANISH
TYPE GUTTER
(TYPICAL)

TOP OF ROOF BEAM

(ROOF BEAM 200X400mm)

C.H.B. WALL WITH CEMENT PLASTER FINISH

DOWNSPOUT

DOWNSPOUT

0.50 m.

3.10 m.

3.10 m.

DOWNSPOUT

TOP OF BEAM

W
1

STACKED SLAB WALL STONE

W
1

C.H.B. WALL WITH CEMENT PLASTER FINISH


AND WATERPROOFING CEMENT BASE

TOP OF BEAM
(FLOOR BEAM 200X400mm)

RESTAURANT
W.I. GRILLES
3.20 m.

3.20 m.

SIGN BOARD
WITH ROLL-UP
DOOR
C.H.B. WALL WITH CEMENT
PLASTER FINISH

D-1
FLOOR FINISH
CORRIDOR LVL.
STREET LVL.

FLOOR FINISH
FINISH GROUND LINE

1 FRONT

A-3

SCALE

1.20 m.

0.10 m.

2 R IGHT SIDE EL EVATION

ELEVATION

A-3

1:45m.

TOP OF BEAM

STREET LVL.

GA. 26 PREPAINTED
RIDGE ROLL

GA. 26
PREPAINTED END
FLASHING

GA. 26
PREPAINTED END
FLASHING

25mm x 300mm
FASCIA BOARD

PREPAINTED RIB TYPE LONG


SPAN ROOFING SHEET

GA. 24 SPANISH
TYPE GUTTER
(TYPICAL)

TOP OF ROOF BEAM

1:45m.

SCALE

1.20 m.

0.10 m.
0.10 m.

A
25mm x 300mm
FASCIA BOARD

C.H.B. WALL WITH CEMENT PLASTER FINISH


AND WATERPROOFING CEMENT BASE

GA. 24 SPANISH
TYPE GUTTER
(TYPICAL)

TOP OF ROOF BEAM

(ROOF BEAM 200X400mm)

3.10 m.

DOWNSPOUT

DOWNSPOUT

C.H.B. WALL WITH CEMENT PLASTER FINISH


AND WATERPROOFING CEMENT BASE

1.50 m.

W
3

1.50 m.

W
3

3.10 m.

C.H.B. WALL WITH CEMENT PLASTER FINISH

TOP OF BEAM

TOP OF BEAM
(FLOOR BEAM 200X400mm)

(FLOOR BEAM 200X400mm)

3.20 m.

3.20 m.

C.H.B. WALL WITH CEMENT


PLASTER FINISH

1.50 m.

W
3

C.H.B. WALL WITH CEMENT PLASTER FINISH


AND WATERPROOFING CEMENT BASE

D-2

FLOOR FINISH

FLOOR FINISH

0.20 m.

STREET LVL.

FINISH GROUND LINE

0.20 m.

3 REAR

A-3

SCALE

JUN MICHAEL A. VELASCO


D

#101 SAO-ATAN PROPER


BANGUED,ABRA

A-3

1:45m.

R.A. 545 :

ARCHITECT:

CP # : 09154462503

4 LEFT SIDE ELEVATION

ELEVATION

P.T.R. No. :

ISSUED ON :

R.E.G. No. :

ISSUED AT :

DRAWINGS AND SPECIFICATIONS DULY SIGNED,


STAMPED OR SEALED, AS INSTRUMENTS OF SERVICE,
ARE THE PROPERTY AND DOCUMENTS OF THE
ARCHITECT AND ENGINEER, WHETHER THE OBJECT
FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT
SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE
WRITTEN CONSENT OF THE ARCHITECT/ENGINEER, TO
DUPLICATE OR MAKE COPIES OF SAID DOCUMENTS
FOR USE IN THE REPETITION OF AND FOR OTHER
PROJECTS OR BUILDINGS, WHETHER EXECUTED
PARTLY OR IN WHOLE.

PROJECT TITLE:

SCALE

OWNER:

1:45m.

SHT. NO.:

SHEET CONTENTS:

DRAWN :

CHECKED :

DESIGNED :

DATE :

3
A

SEE TRUSS DETAILS FOR ROOF


SEE TRUSS DETAILS FOR ROOF

TOP OF ROOF BEAM


TOP OF ROOF BEAM

COMPUTER SHOP

R E S T A U R A N T

3.10 m.

3.10 m.

C O U N T E R

C O U N T E R

OPEN

TOP OF BEAM

SECOND FLOOR LINE

TOP OF BEAM

C A R

SECOND FLOOR LINE

P O R T

3.20 m.

TO

STORAGE ROOM

REF

RIG

STORAGE ROOM

ERA

3.20 m.

C O U N T E R

FIRST FLOOR LINE


FINISH GRADE LINE

FIRST FLOOR LINE


FINISH GRADE LINE

A S E C T I O N

A-4

A-4

1:40m.

W
1

TOP OF BEAM

W
2

0.60 m.

W
3

3
16"

tinted glass
clear outside

3
16"

A-4

#101 SAO-ATAN PROPER


BANGUED,ABRA

CP # : 09154462503

P.T.R. No. :

ISSUED ON :

R.E.G. No. :

ISSUED AT :

D-1

75mm x
200mm(3"x8") Yakal
door head and
jambs

0.60 m.

PVC door panel

tinted glass

44mm (1-3/4")
thick Narra
panel door

44mm (1-3/4")
thick Narra
panel door

D-2

D-3

FLOOR FINISH

A-4
R.A. 545 :

ARCHITECT:

0.70 m.

D DOOR SCHEDULE

1:30m.

SCALE

JUN MICHAEL A. VELASCO


S

1:40m.

smoked glass

FLOOR FINISH LINE

FIRST FLOOR LINE

75mm x
200mm(3"x8") Yakal
door head and
jambs
3
16"

C WINDOW SCHEDULE

B - B

2.10 m.

0.60 m.
0.90 m.

0.50 m.

1.70 m.

1.38 m.

Aluminum
(single-slide)
sliding window

1.50 m.

Steel casement
window frames as
shown

1.00 m.

Aluminum
sliding window

0.55 m.

2.10 m.

2.89 m.

SCALE

" Thick tinted glass

2.10 m.

3
16

SCALE

B S E C T I O N

A - A

DRAWINGS AND SPECIFICATIONS DULY SIGNED,


STAMPED OR SEALED, AS INSTRUMENTS OF SERVICE,
ARE THE PROPERTY AND DOCUMENTS OF THE
ARCHITECT AND ENGINEER, WHETHER THE OBJECT
FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT
SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE
WRITTEN CONSENT OF THE ARCHITECT/ENGINEER, TO
DUPLICATE OR MAKE COPIES OF SAID DOCUMENTS
FOR USE IN THE REPETITION OF AND FOR OTHER
PROJECTS OR BUILDINGS, WHETHER EXECUTED
PARTLY OR IN WHOLE.

PROJECT TITLE:

OWNER:

1:30m.

SCALE

SHT. NO.:

SHEET CONTENTS:

DRAWN :

CHECKED :

DESIGNED :

DATE :

4
A

SECTION DETAILS FOR STIFFENER COLUMN

0.15 m.

7.87 m.
3.25 m.

4.58 m.

200mm O.C.

3.04 m.

WF-1

C2-F2
1.12 m.

0.15 m.
Vertical Bars

C1-F1

C1-F1

1.80 m.

2.86 m.

6" Concrete
Hallow Block
Wall (typical)

Ceramic Tile
Floor Flr. Fin.

1.42 m.

WF-1

Vertical Bars

WF-1

6" Concrete Hallow


Block Wall (typical)

200mm O.C.

TIE BEAM

0.70 m.

2.65 m.

1.10 m.

C2-F2

0.30 m.

1.80 m.

C1-F1

4" Concrete Slab


4" Gravel

0.30 m.

N.G.L.

C1-F1

TIE BEAM

EARTH FILL

EARTH FILL

0.50m. Bothways (typical)

0.35 m.

@ 100mm O.C.

3.26 m.

C1-F1

C1-F1

@ 50mm

4" Concrete
Slab on Fill
(typical)

O.C and Bothways

C2-F2

0.61 m.

WF-1
1.17 m.

4 P L A N

S-1

C1-F1

O F

SCALE

5 SECTION OF C2-F2

C 2 - F 2

S-1

(VERIFY)

(VERIFY)

SCALE

C1-F1

C2-F2

Vertical Bars

1 FOUNDATION PLAN

S-1

Cement Plaster
Finish

1:50m.

SCALE

Bothways

200mm O.C.

1.80 m.

Ceramic Tile
Floor Flr. Fin.
4" Concrete Slab
4" Gravel

N.G.L.
0.30 m.

Vertical Bars

0.30 m.

1.80 m.

4" C.H.B. w/ 10mm

Ceramic Tile
Floor Flr. Fin.

TIE BEAM

0.30 m.

0.70 m.

200mm O.C.

4" Concrete Slab


4" Gravel

EARTH FILL

@ 500mm O.C.
and Bothways

0.35 m.

@ 100mm O.C.

0.70 m.

2.65 m.

8.00 m.

200mm O.C.

0.30 m.

2.70 m.

Short Column
(Stiffener Column)

EARTH FILL

Class A - Footing
Continuous Bars

@ 50mm

0.15 m.

O.C and Bothways

Bar @ 200mm O.C.

1.80 m.
2 P L A N

S-1

O F

SCALE

C 1 - F 1
(VERIFY)

S-1
R.A. 545 :

JUN MICHAEL A. VELASCO


D

#101 SAO-ATAN PROPER


BANGUED,ABRA

CP # : 09154462503

P.T.R. No. :

ISSUED ON :

R.E.G. No. :

ISSUED AT :

6 DETAILS OF C.H.B. WALLS

3 SECTION OF C1-F1

DRAWINGS AND SPECIFICATIONS DULY SIGNED,


STAMPED OR SEALED, AS INSTRUMENTS OF SERVICE,
ARE THE PROPERTY AND DOCUMENTS OF THE
ARCHITECT AND ENGINEER, WHETHER THE OBJECT
FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT
SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE
WRITTEN CONSENT OF THE ARCHITECT/ENGINEER, TO
DUPLICATE OR MAKE COPIES OF SAID DOCUMENTS
FOR USE IN THE REPETITION OF AND FOR OTHER
PROJECTS OR BUILDINGS, WHETHER EXECUTED
PARTLY OR IN WHOLE.

S-1

(VERIFY)

SCALE

PROJECT TITLE:

0.40 m.

OWNER:

(VERIFY)

SCALE

SHT. NO.:

SHEET CONTENTS:

DRAWN :

CHECKED :

DESIGNED :

DATE :

1
S

4.14 m.

2.80 m.

TB

B-2

0.65 m.

0.65 m.

0.85 m.

0.85 m.

B-2

RB-1

7.50 m.

3 P L A N

S-3

S-2

SCALE

O F

2.40 m.
2.35 m.
2.35 m.

RB-1
0.85 m.

RB-1

B-2

O.C. and Bothways

RB-1

3.84 m.

0.85 m.

O.C. and Bothways

RB-1

RB-1
RB-1

RB-1

2.35 m.

B-1

B-1

B-1

1:50m.

2.35 m.

T B

RB-1

B-2

3.84 m.

S-1

RB-1

B-1

B-1

2.35 m.

3.94 m.

CB

B-1

2.35 m.

2.35 m.

RB-1

2.35 m.

S-2

RB-1

RB-1

5.10 m.

O F

2.35 m.

1 SCALE
P L A N

RB-1

B-2

CB

TB

2.80 m.

RB-1

B-2

2.80 m.

TB

4.04 m.

4.04 m.

2.35 m.

7.50 m.

4 P L A N

B - 1

S-2

(VERIFY)

O F

SCALE

R B - 1
(VERIFY)

L1

S-1

L1/3

O.C. and Bothways

L3/4

40mm. Concrete Cover

S-2
Stair
Well

O.C. and Bothways

L/4

L/2

L/4

L2/4

At Support

At Midspan
O.C. and Bothways

S-1

Top Bar

S-2

5 SCHEDULE AND DETAIL OF BEAM

S-2
S-1

SCALE

AS SHOWN

S-2

Stirrups
Bottom Bar

2.35 m.

TB

3.84 m.

RB-1

RB-1

2.40 m.

B-1

2.35 m.

CB

0.89 m.

TB

RB-1

0.93 m.

0.93 m.

CB

0.78 m.

0.73 m.

2.95 m.

TB

TB

2.80 m.

B-2

2.80 m.

TB

4.14 m.

CB

TB

3.94 m.

2.80 m.

RB-1

2.40 m.

TB

B-2

2.40 m.

2.35 m.

TB

2.35 m.

TB

B-1

TB

4.14 m.

0.23 m.

2.80 m.

B-2

B-1

4.04 m.

2.40 m.

TB

0.93 m.

TB

7.87 m.

7.87 m.

0.93 m.

2.40 m.

TB

2.40 m.

TB

Concrete Cover
40mm.

2 SCALE
SECOND FLOOR FRAMING PLAN
1:50m.

BEAM DETAIL

S-2

R.A. 545 :

JUN MICHAEL A. VELASCO


D

#101 SAO-ATAN PROPER


BANGUED,ABRA

CP # : 09154462503

P.T.R. No. :

ISSUED ON :

R.E.G. No. :

ISSUED AT :

DRAWINGS AND SPECIFICATIONS DULY SIGNED,


STAMPED OR SEALED, AS INSTRUMENTS OF SERVICE,
ARE THE PROPERTY AND DOCUMENTS OF THE
ARCHITECT AND ENGINEER, WHETHER THE OBJECT
FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT
SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE
WRITTEN CONSENT OF THE ARCHITECT/ENGINEER, TO
DUPLICATE OR MAKE COPIES OF SAID DOCUMENTS
FOR USE IN THE REPETITION OF AND FOR OTHER
PROJECTS OR BUILDINGS, WHETHER EXECUTED
PARTLY OR IN WHOLE.

PROJECT TITLE:

OWNER:

SHT. NO.:

SHEET CONTENTS:

DRAWN :

CHECKED :

DESIGNED :

DATE :

2
S

Schedule of Stirrups (Typical)

Typical Section TB

Col.

Col.

0.20 m.

Use Grade 40 Reinforcing Steel

0.30 m.

Use Grade 40 Reinforcing Steel

At Support

At Midspan

1 TY PICAL DETAIL FOR TIE BEAM(TB)

Typical Section for CB

2.40 m.

Col.

Typical Section For B-1


0.20 m.

0.40 m.

Bottom Bar
Support

0.15 m.

At Support
L

Col.

Bottom Bar

0.25 m.

0.93 m.

3
L

0.20 m.

C-Beam Details

0.40 m.

S-3

(VERIFY)

SCALE

rest 150mm up to the mid length

0.20 m.

0.30 m.

Support

Section
4Typical
TY P
I C A L for
D ECB
TAIL FOR C-BEAM(CB)

S-3

At Midspan

(VERIFY)

SCALE

Typical Section for Lintel Beam


0.15 m.

0.15 m.

@ Midspan

2 TY PICAL DETAIL FOR BEAM-1(B-1)


(VERIFY)

SCALE

Typical Section for B-2

0.20 m.

0.40 m.

1
4.14 m.

Col.

Col.

Bottom Bar

Bottom Bar

0.20 m.

Bottom Bar

0.40 m.

S-3

At Support

OPEN WALL
FOR WINDOW

At Midspan

OPEN WALL
FOR DOOR

Support

NOTE:PROVIDE A LINTEL BEAM FOR


EVERY WINDOW OR DOOR OPENING
@ Midspan

3 TY PICAL DETAIL FOR BEAM-2(B-2)

S-3

5 TY P IC A L DE TA IL F OR L IN TE L BEA M

(VERIFY)

SCALE

S-3
R.A. 545 :

JUN MICHAEL A. VELASCO


D

#101 SAO-ATAN PROPER


BANGUED,ABRA

CP # : 09154462503

P.T.R. No. :

ISSUED ON :

R.E.G. No. :

ISSUED AT :

DRAWINGS AND SPECIFICATIONS DULY SIGNED,


STAMPED OR SEALED, AS INSTRUMENTS OF SERVICE,
ARE THE PROPERTY AND DOCUMENTS OF THE
ARCHITECT AND ENGINEER, WHETHER THE OBJECT
FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT
SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE
WRITTEN CONSENT OF THE ARCHITECT/ENGINEER, TO
DUPLICATE OR MAKE COPIES OF SAID DOCUMENTS
FOR USE IN THE REPETITION OF AND FOR OTHER
PROJECTS OR BUILDINGS, WHETHER EXECUTED
PARTLY OR IN WHOLE.

PROJECT TITLE:

OWNER:

(VERIFY)

SCALE

SHT. NO.:

SHEET CONTENTS:

DRAWN :

CHECKED :

DESIGNED :

DATE :

2