Documente Academic
Documente Profesional
Documente Cultură
NEOTEK PONSEL
35 Rue Michel MARION - 56850 Caudan
Tl.: +33 (02.97.89.25.30 - Fax :+33 (0)2.97.76.55.72
Email :export@neotek-web.com- www.neotek-ponsel.com
You measure the Oxygen every second or one a month: The OPTOD Dissolved Oxygen Meter ODEON has been made
for you !
Developed according requirements of all extrem situations where oxygen monitoring is essential, especially in wastewater,
aquaculture, drinking water and low oxygen applications.
Thanks to the digital plug and play probe and ODEON autodiagnostic tools, you have confidence in the displayed value.
Displayed status warn you when calibration or caps replace are required.
The large backlighted graphic display and intuitive menus provide you an extrem simplicity of use.
Thanks to low power technology and high memory inside, your instrument has no limits
Clic-Loc Plug
Watertight connectors
Large 4 320 x 240 backlighted screen
Red Photodiode
Inert DO sensitive
elements
Blue LED
ODEON Classic
Data Memory
Data Management
ID (sample, campaign, user)
Reading/Recording
Sensor status Indicator
Autodiagnostic
Display
Power supply
Autonomy
Interfaces
Box
Dimension - Weight
Protection
Operate temperature
Storage temperature
Operate hydrometry
Warranty
100 000 points (with sample ID, User ID, date and time..)
GLP compliance
Alphanumeric, 15 words max, 20 users ID max
3 modes : Manual, interval,continuous
Yes
Yes
Large backlighted graphic LCD 4 display, 240 x 320. Automatic switch in economic mode.
With date, time, user and sample user, C, status, pressure. Simultaneous display of 2
parameters (mg/L and/or % SAT)
4 AA batteries or chargeable batteries (battery charger needed)
200 hours with standard batteries (in economic mode)
USB - 1 RS 485 interface to DO probe External 12 V battery -Charger
PC/ABS
196 x 121x 30 - 400 g
Outdoor instrument, IP 67, Watertight
- 10 to + 60C
- 25 to + 65C
> 80%
2 years
3m
Dx L : 25 x 146 mm, 450 g (with 3 m cable), Inox
Modbus RS 485
Water (wastewater, seawater, naturalwater...), Ethanol, Methanol
0,00 20,00 mg/L _ 0 200% SAT
0,1 mg/L 1% SAT
0,1 %
Pressure, temp, salinity (Mode : Off, Manual, Automatic)
pH 1 -14, CO2, H2S, SO2
-10C 60C
< 5% within 30 000 000 sampling
5 points data (calibration data supplied with a new caps). Possibility of manual calibration
2 years (in the dark, -10C 60C)
2 years for the probe, 1 year for the caps
Standard Package
Meter /datalogger
Probe
Case
Software
Accessories/options
Software
Rechargeable option
External power supply
Cable
NEOTEK PONSEL
35 Rue Michel MARION - 56850 Caudan
Tl.: +33 (02.97.89.25.30 - Fax :+33 (0)2.97.76.55.72
Email :export@neotek-web.com- www.neotek-ponsel.com