Documente Academic
Documente Profesional
Documente Cultură
RE 22058/07.06
Replaces: 06.06
/14
Type M-.SEW
NG 6
Component series 3X
Maximum operating pressure 420/630 bar [6100/9150 psi]
Maximum flow 25 l/min [6.6 gpm]
H7383
Table of contents
Contents
Features
Order code
Standard types
Function, cross-section, symbols
Technical data
Characteristic curves
Features
Page
1
2, 3
3
4, 5
6
7, 8
Power limits
Dimensions
10 to 12
12
Mating connector
13
13
13
General notes
13
/14
M-.SEW
RE 22058/07.06
Order code
M
SEW 6
3X
=2
=3
=4
2 main ports
3 main ports
4 main ports
Poppet valve, direct operated
=6
Main ports
=P
=N
=U
=C
T
a
b
P
T
a
b
P
A
a
Symbols
A
a
b
P
A
a
=D
=Y
T
B
b
= available
= 3X
Component series 30 to 39
(30 to 39: Unchanged installation and connection dimensions)
Operating pressure 420 bar [6100 psi]
Operating pressure 630 bar [9150 psi]
= 420
= 630
=M
24 V DC
205 V DC
96 V DC
For further order codes for other voltages, see page 6
= G24
= G205 1)
= G96
AC electricity supply
system (permissible
voltage tolerance 10%)
Order
code
110 V - 50/60 Hz
96 V
G96
120 V - 60 Hz
110 V
G110
230 V - 50/60 Hz
205 V
G205
RE 22058/07.06
M-.SEW
K4
/14
*
Further details in clear text
No code =
/62 =
No code =
V =
No code =
P=
B12 =
B15 =
B18 =
B20 =
B22 =
Accessories
Inductive position indicator, see RE 24830
Without indicator
Indicator monitors position a
Indicator monitors position b
No code =
QMAG24 2) =
QMBG24 2) =
Electrical connection
Without mating connector with connector as per DIN EN 175301-803
K4 3) =
N9 =
No code =
Note!
Other types of actuators (e. g pneumatic, hydraulic, rotary knob, rotary knob with lock, plunger, lever, roller lever) upon
request!
1) When
connecting to an AC voltage, a DC solenoid and an AC rectifier must be used (see table on page 2).
For individual connections a large mating connector with integrated rectifier can be used (
order separately
, see page 13).
2) 420
3) Mating
Standard types
Type
Material number
M-3SEW 6 C3X/420MG205N9K4
R900050514
M-3SEW 6 C3X/420MG24N9K4
R900566273
M-3SEW 6 C3X/420MG96N9K4
R900570252
M-3SEW 6 U3X/420MG205N9K4
R900050515
M-3SEW 6 U3X/420MG24N9K4
R900566283
M-3SEW 6 U3X/420MG96N9K4
R900570744
/14
M-.SEW
RE 22058/07.06
Basic principle
De-energized position
P and T connected
Energized position
P closed
T
Symbol P
b
P
T
Symbol N
b
P
De-energized position
P closed
Energized position
P and T connected
Note!
The 3/2-way poppet valves have a "negative switching
overlap". Therefore port T must always be connected to tank.
This means that during the switching process from the
start of opening one valve seat to the closing of the other
seat all of the ports PAT are connected with each other.
This, however takes place in such a short space of time that
in most applications it is irrelevant.
The hand override (10) makes it possible to actuate the valve
without energizing the solenoid.
Caution!
Care has to be taken to ensure that the stated maximum
flows are not exceeded! If necessary a throttle orifice for flow
limitation has to be fitted (see page 13).
10
2
a
a
b
P
De-energized position
P and A connected,
T closed
Energized position
P closed,
A and T connected
A
Symbol C
a
a
b
P
De-energized position
P closed,
A and T connected
Energized position
P and A connected,
T closed
6
4
7
9
1
3
Type M-3SEW 6 U
P
A
T
Type M-2SEW 6 N
RE 22058/07.06
M-.SEW
/14
Energized position:
P is connected to A. As the pump pressure acts via A on
the large area of the pilot spool (12), ball (13) is pushed onto
seat (16). Thus, B is connected to T and P to A. Ball (13) in
the plus-1 plate has a "positive switching overlap".
Caution!
In order to prevent pressure intensification when singlerod cylinders are used, the annulus area of the cylinder
must be connected to port A.
The use of the Plus-1 plate allows the following configurations:
A
Symbol D:
Symbol Y:
B
b
b
P
4.2
4.1
9
4.2
15
11
4.1
15
11
P
Plus-1 plate
Type M-4SEW 6 Y
12
14
13
16
/14
M-.SEW
RE 22058/07.06
Technical data (for applications exceeding these parameters, please consult product support!)
General
Weight
Installation orientation
Unrestricted
C [F] 30 to +50 [22 to +122] (NBR seals)
20 to +50 [4 to +122] (FKM seals)
Hydraulic
bar [psi] see power limits on page 9
Maximum flow
Mineral oil (HL, HLP) to DIN51524 1); fast bio-degradable hydraulic fluids to VDMA 24568 (see also
RE90221); HETG (rape seed oil) 1); HEPG (polyglycols) 2); HEES (synthetic esters) 2); other hydraulic
fluids upon request
Hydraulic fluid
Viscosity range
Class 20/18/15 3)
Electrical
Voltage type
Available voltages
4)
DC
AC
% 10
Power consumption
W 30
Duty cycle
% 100
ON
OFF
temperature 5)
1) Suitable
2) Suitable
3) The
ms 25 to 40 (without rectifier)
30 to 55 (with rectifier)
10 to 15 (without rectifier)
35 to 55 (with rectifier)
1/h 15000
IP 65 with mating connector mounted and secured
C [F] 150 [302]
When making the electrical connection, properly connect
the ground conductor (PE ).
RE 22058/07.06
M-.SEW
22
20
16
2
1
12
= 40 C 5 C [104 F 9 F])
12
16
20
24 25
22
20
1
2
16
12
12
16
20
1 M-2SEW 6 N , P to T
1 M-3SEW 6
2 M-3SEW 6 P , P to T
2 M-3SEW 6 U , P to A
3 M-3SEW 6 C , P to A
22
20
16
12
12
16
20
24 25
/14
1 M-4SEW 6
D
, A to T
Y
2 M-4SEW 6
D
, P to A
Y
3 M-4SEW 6
D
, P to B and B to T
Y
24 25
/14
M-.SEW
12
10
8
6
4
2
0
= 40 C 5 C [104 F 9 F])
RE 22058/07.06
12
10
20
24 25
630
600
B12
500
400
B15
300
B18
200
100
B20
0
12
16
20
B22
24 25
2-way circuit
(3/2 directional poppet valve)
2-way circuit
(2/2 directional poppet valve)
Symbol
Remark
T
b
P
b
P
Flow in
l/min
[gpm]
420/630
[6100/
9150]
100
[1450]
25
[6.6]
420/630
[6100/
9150]
100
[1450]
25
[6.6]
420/630
[6100/
9150]
100
[1450]
25
[6.6]
pA pT
420/630
[6100/
9150]
100
[1450]
25
[6.6]
420/630 420/630
[6100/
[6100/
9150]
9150]
100
[1450]
25
[6.6]
420/630 420/630
[6100/
[6100/
9150]
9150]
100
[1450]
25
[6.6]
100
[1450]
25
[6.6]
100
[1450]
25
[6.6]
3-way circuit
pP pA pT
A
pP pT
4-way circuit
= 40 C 5 C [104 F 9 F])
b
P
B
b
Attention!
Please take into account the General guidelines stated on page 13!
The power limits were determined with the solenoids at operating temperature, 10% undervoltage and with the tank not
pressurized.
10/14
M-.SEW
RE 22058/07.06
Dimensions: 2/2 directional poppet valve and 3/2 directional poppet valve
(nominal dimensions in mm [inch])
2
9 1
140 [5.51]
51
[2.01]
[0.33] 8,5
[0,59]
[0,59]
15
23 [0.9]
36,5 [1.44]
15
[0.79]
20
SW22
72,2 [2.84]
116,5 [4.59]
14
125 [4.92]
11
64+1 [2.52+0.39]
[0.54]
7 [0.28]
F1
12
F2
B
A
F4
F2
B
A
F4
3/2 directional
poppet valve
F3
13
F1
Rzmax 4
45 [1.77]
13,8
8
0,01/100mm
10
2/2 directional
poppet valve
F3
For item descriptions and valve mounting bolts see page 12.
RE 22058/07.06
M-.SEW
11/14
[2.01]
9 1 3
140 [5.51]
51
[0,59]
[0,59]
15
81 [3.19]
6
SW22
[0.35]
44,5 [1.75]
23 [0.9]
15
[0.79]
20
62,7 [2.47]
72,2 [2.84]
116,5 [4.59]
11
14
125 [4.92]
0,01/100mm
Rzmax 4
64+1 [2.52+0.39]
F1
7 [0.28]
12, 13
[0.54]
F2
45 [1.77]
13,8
B
AP
F4
F3
For item descriptions and valve mounting bolts see page 12.
12/14
M-.SEW
RE 22058/07.06
Dimensions
1 Solenoid a (ANSI coil designation see RE 08010)
10
Attention!
NFPA T3.5.1
13 Port pattern as per ISO 4401-03-02-0-94,
MR1 and ANSI B93-7 D03 interface (with locating bore
for anti-rotation pin ISO 8752-3x8-St, material number
R900005694, included in the scope of supply)
7 Plus-1 plate
8 Nameplate
9 Hand nut, tightening torque MA = 4 Nm [2.95 ft-lbs]
RE 22058/07.06
M-.SEW
13/14
Cable
gland
M16 x 1,5
1/2 NPT
(Pg16)
Valve side
Material Numbers
Color
Without circuitry
With rectifier
12 240 V
grey
R901017010
a/b
black
R901017011
R901017022
R901017025
R901017026
red/brown
R900004823
a/b
black
R900011039
R900057453
R900842566
The use of the throttle insert is required, if, due to the given
operating conditions, flows can occur during the switching
processes, which exceed the power limit of the valve.
Example:
Accumulator operation,
General notes
Poppet valves must be used in accordance with the spool symbols and the specified operating pressures and flows (see performance limit on page 7).
To ensure their reliable operation, the following points must be
strictly observed:
In order to operate the valve safely and maintain the switched
position, the pressure in pP must be pA pT (for design
reasons).
Poppet valves feature a negative overlap, i.e. during the
switching process, P-A-B leakage occurs. But this process
is completed within such a short time that it is irrelevant in
almost any application.
The specified maximum flow must not be exceeded (if required, use a throttle insert to limit the flow)!
Plus-1 plate:
When using the Plus-1 plate (4/2 directional function), the
following lower operating values must be taken into account:
pmin = 8 bar; qV > 3 l/min.
Ports P, A, B and T are strictly designated and assigned.
They must not be interchanged nor plugged!
Port T must always be connected in the case of a 3- and
4-way operation.
Take note of the pressure level and pressure distribution!
Flow is only permitted in the direction of the arrow!
14/14
M-.SEW
RE 22058/07.06
Notes
Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de
RE 22058/07.06
M-.SEW
15/14
Notes
Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de
16/14
M-.SEW
RE 22058/07.06
Notes
Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de