Sunteți pe pagina 1din 11

R10 BTS FAULT CODE LIST

=====SO CF,
Fault No
CF-1A 0
CF-1A 1
CF-1A 2
CF-1A 3
CF-1A 4
CF-1A 5
CF-1A 6
CF-1A 7
CF-1A 8
CF-1A 9
CF-1A 9
CF-1A 10
CF-1A 11
CF-1A 12
CF-1A 13
CF-1A 14
CF-1A 15
CF-1A 16
CF-1A 17
CF-1A 18
CF-1A 19
CF-1A 20
CF-1A 21
CF-1A 22
CF-1A 23
CF-1A .
CF-1A .
CF-1A 47

Internal Fault Map Class 1A=====


Fault type

=====SO CF,
Not used.
=====SO CF,
Fault No
CF-2A 0
CF-2A 1
CF-2A 2
CF-2A 3
CF-2A 4
CF-2A 5
CF-2A 6
CF-2A 7
CF-2A 8
CF-2A 9
CF-2A 10
CF-2A 11
CF-2A 12
CF-2A 13
CF-2A 14
CF-2A 14
CF-2A 15
CF-2A 16
CF-2A 17
CF-2A 18

Internal Fault Map Class 1B=====

Reset, Power On
Reset, Switch
Reset, Watchdog
Reset, SW Fault
Reset, RAM Fault
Reset, Internal Function Change
XBus Fault
Timing Unit VCO Fault
(R9 only) Time Distribution Fault
(R10 only) Timing Bus Fault
Indoor Temp Out of Safe Range
DC Voltage Out Of Range
Bus Fault
IDB Corrupted
RU Data Base Corrupted
HW And IDB Inconsistent
Internal Configuration Failed
HW Fault
Air Time Counter Lost
(R10 only) Time Distribution Fault

Internal Fault Map Class 2A=====


Fault Type
Reset, Power On
Reset, Switch
Reset, Watchdog
Reset, SW Fault
Reset, RAM Fault
Reset, Internal Function Change
RX Internal Amplifier Fault
VSWR Limits Exceeded
Power Limits Exceeded
DXU-Opt EEPROM Checksum Fault
RX Maxgain/Mingain Violated
Timing Unit VCO Ageing
(R9 only) Supervision/Communication Lost
(R10 only) CDU Supervision/Communication Lost
VSWR/Output Power Supervision Lost
Indoor Temp Out Of Normal Conditional Range
Indoor Humidity
DC Voltage Out Of Range

CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A
CF-2A

19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
.
.
95

=====SO CF,
Fault No
EXT CF-1B 4
EXT CF-1B 5

Power and Climate System in Standalone Mode


Internal Power Capacity Reduced
Battery Backup Capacity Reduced
Climate Capacity Reduced
HW Fault
Loadfile Missing in DXU or ECU
Climate Sensor Fault
System Voltage Sensor Fault
A/D Converter Fault
Varistor Fault
Bus Fault
High Frequency of Software Fault
Non-Volatile Memory Corrupted
RX Diversity Lost
Output Voltage Fault
Optional Synchronization Source
RU Data Base Corrupted
Circuit Breaker Tripped or Fuse Blown
Default Values Used
RX Cable Disconnected
Reset, DXU Link Lost
Lost communication to TRU
Lost communication to ECU
Internal Configuration Failed
ESB Distribution Failure
High Temperature
DB parameter fault
Antenna Hopping Failure
GPS Synch Fault
Battery Backup time shorter than expected
RBS running on battery
TMA Supervision/Communications Lost
CXU Supervision/Communication Lost
HW and IDB Inconsistent

External Condition Map Class 1=====


Fault Type
L/R SWI (BTS In Local Mode)
L/R TI (Local to Remote while Link Lost)

=====SO CF, External Condition Map Class 2=====


Fault No
Fault Type
EXT CF-2A 9 RBS DOOR (RBS cabinet door open)
EXT CF-2A 10 MAINS FAIL (External power source fail)
EXT CF-2A 11 ALNA/TMA Fault
EXT CF-2A 12 ALNA/TMA Degraded
EXT CF-2A 13 Auxiliary Equipment Fault
EXT CF-2A 14 Battery Backup External Fuse Fault
EXT CF-2A 15
=====SO CF, Replacement Unit Map=====
No
Replacement Unit
CF RU 0
DXU or IXU

CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF

RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU
RU

1
2
3
4
5
6
7
8
8
9
9
10
11
12
13
14
15
16
17
18
19
20
21
21
22
23
24
25
26
27
27
28
28
29
30
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51

ECU

MICRO RBS

Y LINK
TIM
CDU
CCU
PSU

(R9 only)
(R10 only) BFU
(R9 only) BDM or BFU or BFU Fuse or Circuit Breaker
(R10 only) BDM
ACCU
ACTIVE COOLER
ALNA/TMA A
ALNA/TMA B
BATTERY
FAN
HEATER
HEAT EXCHANGER EXT FAN
HEAT EXCHANGER INT FAN
HUMIDITY SENSOR
TMA CM
(R9 only) TEMPERATURE SENSOR or ACTIVE COOLER FAN
(R10 only) TEMPERATURE SENSOR
CDU HLOUT HLIN CABLE
CDU RX IN CABLE
CU
DU
FU
(R9 only) FU CU PFWD CABLE or CDU CDU PFWD CABLE
(R10 only) FU CU PFWD CABLE
(R9 only)FU CU PREFL CABLE or CDU CDU PREFL CABLE
(R10 only) FU CU PREFL CABLE
CAB HLIN CABLE
(R9 only) CDU BUS/IOM BUS
(R10 only) CDU BUS
ENVIRONMENT
LOCAL BUS
EPC BUS / POWER COMMUNICATION LOOP
IDB
TIMING BUS
CDU CXU RXA CABLE
CDU CXU RXB CABLE
XBUS
ANTENNA
PSU DC CABLE
CXU
FLASH CARD
BATTERY TEMP SENSOR
FCU
TMA_CM CABLE
GPS RECEIVER or LMU
GPS RECEIVER DXU CABLE
ACTIVE COOLER FAN
BFU Fuse or Circuit Breaker

CF
CF
CF
CF
CF
CF
CF
95

RU
RU
RU
RU
RU
RU
RU

52
53
54
55
56
57
58

CDU
CDU
IOM
ASU
ASU
ASU
ASU

CDU
CDU
BUS
RXA
RXB
CDU
CDU

PFWD CABLE
PREFL CABLE
UNITS OR CABLES
UNITS OR CABLES
RXA CABLE
RXB CABLE

=====SO TRXC, Internal Fault Map Class 1A=====


Fault No
Fault Type
TRX-1A 0
TRX-1A 1
Reset, Power On
TRX-1A 2
Reset, Switch
TRX-1A 3
Reset, Watchdog
TRX-1A 4
Reset, SW Fault
TRX-1A 5
Reset, RAM Fault
TRX-1A 6
Reset, Internal Function Change
TRX-1A 7
TRX-1A 8
Timing Reception Fault
TRX-1A 9
Signal Processing Fault
TRX-1A 10
RX Communication Fault
TRX-1A 11
DSP CPU Communication Fault
TRX-1A 12
Terrestrial Traffic Channel Fault
TRX-1A 13
RF Loop Test Fault
TRX-1A 14
RU Data Base Corrupted
TRX-1A 15
XBus Communication Fault
TRX-1A 16
Initiation Fault
TRX-1A 17
X-Interface Fault
TRX-1A 18
DSP Fault
TRX-1A 19
Reset, DXU Link Lost
TRX-1A 20
HW And IDB Inconsistent
TRX-1A 21
Internal Configuration Failed
TRX-1A 22
Voltage Supply Fault
TRX-1A 23
Air Time Counter Lost
TRX-1A 24
High Temperature
TRX-1A 25
TX/RX Communication Fault
TRX-1A 26
Radio Control System Load
TRX-1A 27
Traffic Lost Downlink
TRX-1A 28
Traffic Lost Uplink
TRX-1A 29
Y Link Communication HW Fault
TRX-1A 30
DSP RAM Soft Error
.
.
TRX-1A 47
=====SO TRXC, Internal Fault Map Class 1B=====
Fault No
Fault Type
TRX-1B 0
CDU/Combiner Not Usable
TRX-1B 1
Indoor Temp Out Of Safe Range
TRX-1B 2
TRX-1B 3
DC Voltage Out Of Range
TRX-1B 4
TRX-1B 5
TRX-1B 6
TRX-1B 7
TX Address Conflict
TRX-1B 8
Y Link Communication Fault

TRX-1B 9
TRX-1B 10
.
.
TRX-1B 47

Y Link Communication Lost


Timing Reception Fault

=====SO TRXC, Internal Fault Map Class 2A=====


Fault No
Fault Type
TRX-2A 0
RX Cable Disconnected
TRX-2A 1
RX EEPROM Checksum Fault
TRX-2A 2
RX Config Table Checksum Fault
TRX-2A 3
RX Synthesizer Unlocked
TRX-2A 4
RX Internal Voltage Fault
TRX-2A 5
RX Communication Fault
TRX-2A 6
TX Communication Fault
TRX-2A 7
TX EEPROM Checksum Fault
TRX-2A 8
TX Config Table Checksum Fault
TRX-2A 9
TX Synthesizer Unlocked
TRX-2A 10
TX Internal Voltage Fault
TRX-2A 11
TX High Temperature
TRX-2A 12
TX Output Power Limits Exceeded
TRX-2A 13
TX Saturation
TRX-2A 14
Voltage Supply Fault
TRX-2A 15
VSWR/Output Power Supervision Lost
TRX-2A 16
Non-Volatile Memory Corrupted
TRX-2A 17
Loadfile Missing in TRU
TRX-2A 18
DSP Fault
TRX-2A 19
High Frequency of Software Fault
TRX-2A 20
RX Initiation Fault
TRX-2A 21
TX Initiation Fault
TRX-2A 22
CDU-Bus Communication Fault
TRX-2A 23
Default Values Used
TRX-2A 24
TRX-2A 25
TX Max Power Restricted
TRX-2A 26
DB parameter fault
TRX-2A 27
TRX-2A 28
TRX-2A 29
Power Amplifier Fault
TRX-2A 30
CPU High Temperature
TRX-2A 31
TRX-2A 32
RX High Temperature
TRX-2A 33
Inter TRX Communication Fault
TRX-2A 34
TRX-2A 35
Traffic Burst Inhibit
TRX-2A 36
RX Filter Loadfile Checksum Fault
TRX-2A 37
RX Internal Amplifier Fault
TRX-2A 38
Climate Capacity Reduced
TRX-2A 39
RF-loop Test Fault, Degraded RX
TRX-2A 40
Memory Fault
TRX-2A .
TRX-2A .
TRX-2A 47

=====SO TRXC, External Condition Map Class 1=====


Fault No
Fault Type

EXT TRX-1B 4
EXT TRX-1B 5

L/R SWI (TRU In Local Mode)


L/R TI (Local to Remote while Link Lost)

===== SO TRXC, External Condition Map Class 2=====


Not used.
=====SO TRXC, Replacement Unit Map=====
No
RU
TRX RU 0
TRU, dTRU or RRU
TRX RU 1
TRX RU 2
MICRO RBS
TRX RU 3
CXU TRU RXA CABLE
TRX RU 4
CXU TRU RXB CABLE
TRX RU 5
TRX RU 6
TRX RU 7
TRX RU 8
TRX RU 9
TRX RU 10
CDU TO TRU PFWD CABLE
TRX RU 11
CDU TO TRU PREFL CABLE
TRX RU 12
CDU TO TRU RXA CABLE
TRX RU 13
CDU TO TRU RXB CABLE
TRX RU .
TRX RU .
TRX RU 47
TRX RU
=====AO CON, Internal Fault Map Class 1A=====
Not used.
=====AO CON, Internal Fault Map Class 1B=====
Not used.
=====AO CON, Internal Fault Map Class 2A=====
Not used.
=====AO CON, External Condition Map Class 1=====
Fault No Fault Type
EXT CON-1B 8 LAPD Q CG (LAPD Queue Congestion)
=====AO CON, External Condition Map Class 2=====
Fault No Fault Type
EXT CON-2B 8 LAPD Q CG (LAPD Queue Congestion)
=====AO CON, Replacement Unit Map=====
Not used. See Replacement Unit Map for SO CF for
possible HW causing the fault.
=====AO IS=====
AO IS is not supervised.
=====AO RX, Internal Fault Map Class 1A=====
Not used.
=====AO RX,
Fault No
RX-1B 0
RX-1B 1

Internal Fault Map Class 1B=====


Fault type
RX Internal Amplifier Fault
ALNA/TMA Fault

RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B
RX-1B

2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
.
.
47

=====AO RX,
Fault No
RX-2A 0
RX-2A 1
RX-2A 2
.
.
RX-2A 47

RX EEPROM Checksum Fault


RX Config Table Checksum Fault
RX Synthesizer A/B Unlocked
RX Synthesizer C Unlocked
RX Communication Fault
RX Internal Voltage Fault
RX Cable Disconnected
RX Initiation Fault
CDU Output Voltage Fault
TMA CM Output Voltage Fault
CDU Supervision/Communication Fault
RX High Temperature
TMA Supervision Fault
TMA Power Distribution Fault
RX Filter Loadfile Checksum Fault
RX Auxiliary Equipment Fault
Internal Fault Map Class 2A=====
Fault type
CXU Supervision/Communication Fault
RX Path Lost on A receiver side
RX Path Lost on B receiver side

=====AO RX, External Condition Map Class 1====


Not used.
=====AO RX, External Condition Map Class 2=====
Not used.
=====AO RX, Replacement Unit Map=====
Not used. See Replacement Unit Map for SO CF and SO
TRXC for possible HW causing the fault.
=====AO TF, Internal Fault Map Class 1A=====
Not used.
=====AO TF,
Fault No
TF-1B 0
TF-1B 1
TF-1B 2
.
.
TF-1B 47

Internal Fault Map Class 1B=====


Fault Type
Optional Synchronization Source
DXU-Opt EEPROM Checksum Fault
GPS Synch Fault

=====AO TF, Internal Fault Map Class 2A=====


Fault No
Fault Type
TF-2A 0
Frame Start Offset Fault
.

.
TF-2A 47
=====AO TF,
Fault No
EXT TF-1B 0
EXT TF-1B 1

External Condition Map Class 1=====


Fault Type
EXT SYNCH (No Usable External Reference)
PCM SYNCH (No Usable PCM-Reference)

=====AO TF, External Condition Map Class 2=====


Fault No Fault Type
EXT TF-2B 0 EXT SYNCH (No Usable External Reference)
EXT TF-2B 1 PCM SYNCH (No Usable PCM-Reference)
=====AO TF, Replacement Unit Map=====
Not used. See Replacement Unit Map for SO CF for
possible HW causing the fault.
=====AO TS, External Condition Map Class 1=====
Fault No
Fault Type
EXT TS-1B 3 TRA/PCU (Remote Transcoder/PCU Com. Lost)
=====AO TX, Internal Fault Map Class 1A=====
Fault No
Fault type
TX-1A 0
TX Offending
=====AO TX,
Fault No
TX-1B 0
TX-1B 1
TX-1B 2
TX-1B 3
TX-1B 4
TX-1B 5
TX-1B 6
TX-1B 7
TX-1B 8
TX-1B 9
TX-1B 10
TX-1B 11
TX-1B 12
TX-1B 13
TX-1B 14
TX-1B 15
TX-1B 16
TX-1B 17
TX-1B 18
TX-1B 19
TX-1B 20
TX-1B 21
TX-1B 22
TX-1B 23
TX-1B 24
TX-1B 25
TX-1B 26
TX-1B 27
TX-1B 28

Internal Fault Map Class 1B=====


Fault type
CU/CDU Not Usable
CDU/Combiner VSWR Limits Exceeded
CDU Output Power Limits Exceeded
TX Antenna VSWR Limits Exceeded
TX
TX
TX
TX
TX
TX
TX
TX
TX

EEPROM Checksum Fault


Config Table Checksum Fault
Synthesizer A/B Unlocked
Synthesizer C Unlocked
Communication Fault
Internal Voltage Fault
High Temperature
Output Power Limits Exceeded
Saturation

TX Initiation Fault
CU/CDU HW Fault
CU/CDU SW Load/Start Fault
CU/CDU Input Power Fault
CU/CDU Park Fault
VSWR/Output Power Supervision Lost
CU/CDU Reset, Power On
CU Reset, Communication Fault
CU/CDU Reset, Watchdog
CU/CDU Fine Tuning Fault
TX Max Power Restricted
CDU High Temperature

TX-1B 29
TX-1B 30
TX-1B 31
TX-1B 32
TX-1B 33
.
.
TX-1B 47
=====AO TX,
Fault No
TX-2A 0
.
.
47

TX CDU Power Control Fault


Power Amplifier Fault
TX Low Temperature
CDU-Bus Communication Fault
TX Auxiliary Equipment Fault
Internal Fault Map Class 2A=====
Fault Type
TX Diversity Fault

^^^^^ LOGICAL RU ^^^^^


A unit which can be refered to but is not a single
pysical unit. There are tree different kinds of logical RUs:
1. BUSSES
-XBUS
-LOCAL BUS
-TIMING BUS
-CDU BUS
-POWER COMMUNICATION LOOP
2. ANTENNAS
-RX A
-RX B
-TX A
-TX B
3. ENVIRONMENT
-TEMPERATURE
^^^^^^ BITMAP
000000000001
000000000002
000000000004
000000000008
000000000010
000000000020
000000000040
000000000080
000000000100
000000000200
000000000400
000000000800
000000001000
000000002000
000000004000
000000008000
000000010000
000000020000
000000040000
000000080000
000000100000
000000200000
000000400000
000000800000

FOR RXELP:MO=; ^^^^^^^^^^^^^^^^^^


0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

000001000000
000002000000
000004000000
000008000000
000010000000
000020000000
000040000000
000080000000
000100000000
000200000000
000400000000
000800000000
001000000000
002000000000
004000000000
008000000000
010000000000
020000000000
040000000000
080000000000
100000000000
200000000000
400000000000
800000000000

24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47

^^^^^^^^^^^^^^^^ DIGITAL PATH FAULTS ^^^^^^^^^^^^^^^


DIP fault 1
Alarm indication signal AIS
DIP fault 2
Loss of frame alignment
DIP fault 3
Excessive error rate
DIP fault 4
Alarm indication from the remote end
DIP fault 5
Alarm indication signal in time slot 16
DIP fault 6
Loss of multiframe alignment
DIP fault 7
Alarm ind. from remote end signalling equipment
DIP fault 8
Alarm indication signal ALL1
DIP fault 9
Loss of CRC multiframe alignment
DIP fault 10
Consectutive severely errrored seconds
^^^^^^^^^^^ RADIO X-CEIVER ADMINISTRATION ^^^^^^^^^^^^
MANAGED OBJECT STATUS
BTS: Last known state of the MO in the BTS
RES= MO is in state RESET
STA=
STARTED
DIS=
DISABLED
ENA=
ENABLED
BITMAP for BLO (Blocking origin of automatic blocking)
HEX
BIT
xxx1
0 AP object blocked from own superv. perm.
xxx2
1 AT object blocked from own superv.
temp.
xxx4
2 AS object blocked due to fault suspected
xxx8
3 TG object blocked from TG
xx10
4 TRXC
object blocked from TRXC
xx20
5 TGC
object blocked from TGC
xx40
6 OML
object blocked from OML
xx80
7 X spare
x100
8 LMT
obj. blo. due to local maint. activities
x200
9 CF object blocked from CF

10

x400
x800

10 LOM
11 LOOP

object blocked from due to local mode


obj. blo. from due to loop test failure

BITMAP for BLA (Blocking origin of blocking due to action not completed)
HEX
BIT
xxx1
0 BNU obj. needs reset & uncond. load or reset & load. in progr.
xxx2
1 BNR obj. needs reset & load check or reset & load. in progr.
xxx4
2 BNL
obj. needs reset and load check or loading in progress
xxx8
3 BNP
obj. needs polling or polling in progress
xx10
4 BNT
obj. needs testing or testing in progress
xx20
5 BNI
obj. needs intermittent test or interm. test in progr.
xx40
6 BND
obj. needs updating of MO data
xx80
7 BNS
obj. needs to be started
x100
8 BNM
obj. needs to be manually deblocked (BTS initiated)
x200
9 BNO
obj. needs loop test or loop loop test in progress
BITMAP for LMO (Blocking origin of logical managed object TS)
HEX
BIT
xx20
5 CRN
LTS blocked due to creation in progress
xx40
6 ENA
LTS blocked due to not enabled
xx80
7 X
x100
8 MO
LTS blocked from TS
x200
9 LTF
LTS blocked from LTF
x400 10 RSL
RSL blocked from RSL
x800 11 DEV
LTS blocked from speech/data device
1000 12 X
2000 13 SYNCB
LTS blo. due to sync. fault in BTS
4000 14 X
8000 15 CHG
blocked due to change
BITMAP for LMO (Blocking origin of logical managed object TF)
HEX
BIT
xx20
5 CRN
LTF blocked due to creation in progress
xx40
6 ENA
LTF blocked due to not enabled
xx80
7 X
x100
8 MO
LTF blocked from TF

11

S-ar putea să vă placă și