accommodate the voltage required by the load. For many electrical circuits, the
National Electrical Code (NEC) requires a separately derived neutral secondary
connection provided by Delta-Wye connected transformers.
Transformers are manufactured in a variety of choices to meet many applications.
Dry-type transformers are offered encapsulated, ventilated or non-ventilated, 600
Volt Class, isolation type, single and three phase, through 500 kVA. Indoor and
outdoor models are an option.
General purpose transformers can be located close to the load. No vaults are required
for installation and no long, expensive feeder lines are needed. Common applications
include inductive and resistive loads such as motors, lighting and heating.
I would not recommend the centre earthed system shown in Fig 4. There are some
old control systems arranged like this but it is not necessary with modern control
equipment.
Control circuits supplied directly phase phase or phase neutral are only permitted
where a single motor starter is controlled and there are a maximum of two control
devices. (EN 60204-1 9.1.1)
Direct supplied control circuits should not be used where the control circuits go
outside a control enclosure, for example to limit switches.
Extracts from EN60204-1:2006+A1:2009 Electrical Equipment of Industrial
machines
9.1.1 Control circuit supply
Where control circuits are supplied from an a.c. source, control transformers shall be
used for
supplying the control circuits. Such transformers shall have separate windings. Where
several transformers are used, it is recommended that the windings of those
transformers be
connected in such a manner that the secondary voltages are in phase.
Where d.c. control circuits derived from an a.c. supply are connected to the
protective
bonding circuit, they shall be supplied from a separate winding of the a.c. control
Method c) Where the control circuit is not fed from a control transformer and is
either:
1) directly connected between the phase conductors of an earthed supply, or;
2) directly connected between the phase conductors or between a phase conductor
and a
neutral conductor of a supply that is not earthed or is earthed through a high
impedance,
Multi-pole control switches that switch all live conductors are used for START or STOP
of
those machine functions that can cause a hazardous situation or damage to the
machine in
the event of unintentional starting or failure to stop, or in the case of c) 2), a device
shall be
provided that interrupts the circuit automatically in the event of an earth fault.