Sunteți pe pagina 1din 40

TA1179-D-5212-1000

NOT TO SCALE

LINE

VALVE INSTRUMENT AND LINE SYMBOLS

LINE IDENTIFICATION
X "- AA - BBBB - SPEC -IN

GATE VALVE NORMALLY OPEN

`T' TYPE STRAINER

GATE VALVE NORMALLY CLOSED

`Y' TYPE STRAINER

(OPTIONAL DESIGNATION)

GLOBE VALVE NORMALLY CLOSE

PIPE MATERIAL SPECIFICATION

CHECK VALVE

CONE TYPE STRAINER


BASKET STRAINER

BUTTERFLY VALVE

BAG FILTER

PLUG VALVE

LINE SIZE (IN INCHES)

CANDLE FILTER

BALL VALVE

LINE LEGEND

NEEDLE VALVE

PROCESS/UTILITY LINE
BURIED LINE

ANGLE VALVE

VENDOR LIMIT LINE

SPECTACLE BLIND (OPEN)

BLOWDOWN ANGLE VALVE

FUTURE LINE

SPECTACLE BLIND (CLOSE)

DIAPHRAGM VALVE

TRACED LINE

SPACER

ANGLE BALL VALVE

INSTRUMENT LINE SYMBOLS


(HARDWIRED)

CAPILLARY TUBING

(FILLED SYSTEM)

EXPANDER/REDUCER
3-WAY VALVE

PNEUMATIC SIGNAL

HYDRAULIC SIGNAL

OPEN DRAIN FUNNEL

ANGLE CHOKE VALVE


ELETRICAL SIGNAL

SOFTWARE SIGNAL

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

INSULATION SPECIFICATION

TEMPORARY STRAINER

TS

GLOBE VALVE NORMALLY OPEN

LINE NUMBER (FIRST DIGIT


INDICATES ORIGIN)
PRODUCT IDENTIFICATION

BELLOWS

CONTROL VALVE
(GENERAL/ GLOBE)

ST

STEAM TRAP

CONTROL VALVE (BALL)

AT

AIR TRAP

MT

MOISTURE TRAP

CONTROL VALVE (DIAPHRAGM)

ELETROMAGNETIC/ SONIC SIGNAL

RUPTURE DISC

CONTROL VALVE (BUTTERFLY)

PRODUCT IDENTIFICATION

UNION

3-WAY CONTROL VALVE

COUPLING

PRODUCTID
10
11
12
21
22
23
24
25
26
31
32
33
34
35
61
62
63
64

CONTROL VALVE (ANGLE TYPE)

PRODUCTNAME
CPO
RBDST
METHANOL
RBDPO
SLOPBIODIESEL
SLOPGLYCERIN
CRUDEGLYCERIN
YELLOWGLYCERIN
INTERMEDIATEBIODIESEL
BIODIESEL
PFAD
REFINEDGLYCERIN
PITCHGLYCERIN
FATTYMATTER
SODIUMMETHYLATE
HYDROCHLORICACID
SODIUMHYDROXIDE
PHOSPHORICACID

CAP WELDED
DRAIN DIRECTION

CONTROL VALVE
WITH POSITIONER
PILOT OPERATED

SLOPE
VALVE

FLAME ARRESTOR
GOOSE NECK VENT
WITH BIRD MESH

CONTROL VALVE
WITH HAND WHEEL

CONTINUTY
ARROW, LINES

PLUNGER OPERATED VALVE

PIPE MATERIAL SPECIFICATION

CAP THREADED

CONTROL VALVE
(UPSTREAM SELF ACUATING)

MOTOR OPERATED VALVE

MATERIAL
CARBONSTEEL
CARBONSTEEL(HIGHTEMP.)
CARBONSTEEL(VACUUM)
SS304L
SS304L(VACUUM)
SS316L
SS316L(HIGHTEMP.)
SS316L(VACUUM)
SS316L
PVDF
PVDF
TEFLONLINEDCARBONSTEEL
FRP

BLIND FLANGE

CONTROL VALVE
(DOWNSTREAM SELF ACUATING)

CODE
A001
A002
A003
B001
B003
C001
C002
C003
C004
D003
D001
D002
E001

GENERAL ABBREVIATIONS

SOLENOID VALVE (2-WAY)

SPECIFICATION
API5L
API5L
API5L
ASTMA182F304L
ASTMA182F304L
ASTMA182F316L
ASTMA182F316L
ASTMA182F316L
ASTMA182F316L
ASTMF1673
ASTMF1673
ASTMA53PTFE
API15LR

SCHEDULE
40
40
40
10S
10S
10S
10S
10S
10S
40
40
40
ASMEB31.3

CONTINUTY ARROW,
INST. SIGNAL
PULSATION DAMPNER

SOLENOID VALVE (3-WAY)

RATING
150#
150#
150#
150#
150#
150#
150#
150#
150#
PN10
PN10
150#
150#

VORTEX BRAKER
FLEXBLE LINE/ HOSE

DRAIN WITH BLIND FLANGE


DRAIN WITH THREADED CAP
VENT WITH THREADED CAP

SP
xx

SPECIALITY ITEM

UTP
xx

UTILITY TIE-IN POINT

INSTRUMENTATION SYMBOLS AND LEGEND

PSV
PVV
RCC
TE
TI
TL
TRV
TSO
TT
UC
VAC
VFD
XL
ZSC
ZSH
ZSL
ZSO

AUTO RESET
ATMOSPHERE
AIR VENT VALVE
BIODIESEL
BATTERY LIMIT
CONVENTIONAL BUOY MOORING
CONTROL ROOM MANUAL RESET (FOR SOV)
CHEMICAL SEWER
CAR SEAL CLOSED
CAR SEAL OPEN
DOUBLE BLOCK & BLEED
DIESEL GENERATOR
DIFFERENTIAL PRESSURE GAUGE
EMERGENCY RELIEF VALVE
EMERGENCY SHUT DOWN
FULL BORE
FAIL CLOSED
FINISHED GROUND LEVEL
FAIL LOCK
FIELD MANUAL RESET(FOR SOV)
FAIL OPEN
HAND SWITCH
HAND CONTROL VALVE
INSIDE BATTERY LIMIT
LEVEL ALARM
LOCK CLOSE
LEVEL GAUGE
LEVEL INDICATOR
LOW LIQUID LEVEL
LOCK OPEN
LEVEL SWITCH
LEVEL SWITCH HIGH HIIGH
LEVEL TRANSMITTER
LEVEL SWITCH (SIL CERTIFIED)
MOTOR OPERATED VALVE
MANWAY
NORMALLY CLOSED
NORMAL LIQUID LEVEL
NORMALLY NO FLOW
NORMALLY OPEN
OIL INDICATOR
OIL MONITOR
OUTSIDE BATTERY LIMIT
PUSH BUTTON
SELF ACTUATED PRESSURE REGULATOR
PRESSURE DIFFERENTIAL INDICATOR
PRESSURE INDICATOR
PRESSURE INDICATOR TRANSMITTER
PIG INDICATOR
PRESSURE SAFETY VALVE
PRESSURE VACUUM RELIEF VALVE
REINFORCED CEMENT CONCRETE
TEMPERATURE ELEMENT
TEMPERATURE INDICATOR
TANGENT LINE
THERMAL RELIEF VALVE
TIGHT SHUT OFF
TEMPERATURE TRANSMITTER
UTILITY CONNECTION
VACUUM
VARIABLE FREQUENCY DRIVE
PUMP RUNNING INDICATION LAMP
POSITION SWITCH CLOSE
POSITION SWITCH HIGH (VALVE OPEN)
POSITION SWITCH LOW (VALVE CLOSE)
POSITION SWITCH OPEN

XS
XA

SWITCH
FAULT ALARM

AR
ATM
AVV
BD
BL
CBM
CMR
CS
CSC
CSO
DBB
DG
DPG
ERV
ESD
FB
FC
F.G.L
FL
FMR
FO
HS
HV
ISBL
LA
LC
LG
LI
LLL
LO
LS
LSHH
LT
LZS
MOV
MW
NC
NLL
NNF
NO
OI
OM
OSBL
PB
PCV
PDI
PI
PIT
PIG SIG

NOTE :INSTRUMENTATION SYMBOLS AND LEGEND SHALL BE AS PER


ISA STANDARDS AND RECOMMENDED PRATICES FOR
INSTRUMENTATION AND CONTROL.

IJ

MEASURED
OR
INITIATING VARIABLE

SUCCEEDING - LETTERS
READOUT
OR
PASSIVE FUNCTION

MODIFIER

ANALYSIS

ALARM

BURNER, COMBUSTION

USER'S CHOICE

USER'S CHOICE

USER'S CHOICE

VOLTAGE

FLOW RATE

USER'S CHOICE

HAND

CURRENT (ELECTRICAL)

POWER

SCAN

TIME, TIME SCHEDULE

TIME RATE OF
CHANGE

LEVEL

USER'S CHOICE

OUTPUT
FUNCTION

USER'S CHOICE
CONTROL

DIFFERENTAL
SENSOR
(PRIMARY ELEMENT)
RATIO (FRACTION)
GLASS,
VIEWING DEVICE
HIGH
INDICATE

CONTROL STATION
LIGHT

LOW
MIDDLE,

MOMENTARY

USER'S CHOICE

USER'S CHOICE

USER'S CHOICE

ORIFICE RESTRCTION

PRESSURE VACUUM

POINT (TEST)
CONNECTION

QUANTITY

RADIATION

SPEED, FREQUENCY

TEMPERATURE

MULTIVARIABLE

VIBRATION, MECHANICAL
ANALYSIS

USER'S CHOICE

INTEGRATE / TOTALIZE
RECORD
SAFETY

SWITCH
TRANSMIT
MULTIFUNCTION

MULTIFUNCTION

WELL

UNCLASSFIED

X AXIS

EVENT STATE OR
PRESENCE

Y AXIS

RELAY, COMPUTE
CONVERT

POSITION DIMENSION

Z AXIS

DRIVER, ACTUATOR,
UNCLASSFIED FINAL
CONTROL ELEMENT

UNCLASSFIED

FUNCTION BLOCKS
FUNCTION DESCRIPTIONS
SYMBOL

VALVE, DAMPER
LOUVER

W WEIGHT, FORCE

No.

MODIFIER

No.

FUNCTION

UNCLASSFIED

UNCLASSFIED

DCS/COMPUTER SYSTEM SYMBOLS


SYMBOL

INSULATING ISOLATION JOINT

CC

CORROSION COUPON

CP

CORROSION PROBE

SUMMING

AVERAGING

DIFFERENCE

PROPORTIONAL

12

TIME FUNCTION

13

HIGH SELECTING

14

LOW SELECTING

15

HIGH LIMITING

F(t)

FUNCTION ON PLC

INSULATION FLANGE

TURBINE METER

ALLPIPINGSHALLFOLLOWASMEB31.3;FLANGESASMEB16.5.FORPVDFEN10921SHALLBE
FOLLOWED.

IDENTIFICATION LETTERS
FIRST - LETTER

SILENCER
FLOW ELEMENT (ORIFICE)

NOTES :

FM

PD METER

FLOW METER

RUNNING LIGHT (LOCAL)


ROTAMETER
S

SONIC METER

MAGNETIC METER

OM

SC
AP
SP
AA
AS
AG
NP

PITOT TUBE
ANNUBAR

OIL MONITOR
-

RTU

HORIZONTAL CENTRIFUGAL
PUMP WITH MOTOR

INLET SIZE, INCHES

SET PRESSURE Kg/Cm g


RELIEF VALVE

POSITIVE DISPLACEMENT OR
SCREW PUMP WITH MOTOR

HOT INSULATION
COLD INSULATION
PERSONNEL PROTECTION
STEAM TRACED
ELECTRICAL TRACED
STEAM JACKETED
NON-INSULATED

LESS FREQUENTLY USED SYMBOLS

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

DERIVATIVE

MULTIPLYING

DIVIDING

ROOT EXTRACTION

16
d

17

dt

18

LOW LIMITING

DISPLAY.

REVERSE
PROPORTIONAL

PRESSURE VACUUM
SAFETY VALVE

10

AIR-OPERATED DOUBLE
DIAPHRAGM (AODD) PUMPS

11

CONTINUOUS DRAIN

NON LINEAR OR
UNSPECIFIED
FUNCTION

F(x)

LOCAL INTERLOCK FUNCTION.

E
I
P
A
H
D

VOLTAGE
CURRENT
PNEUMATIC
ANALOG
HYDRAULIC
DIGITAL

SPRING LOADED VALVE

TNB

TNB

30/10/15

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

DESCRIPTION

IZ

LOCAL SAFETY INTERLOCK FUNCTION.

DATE

PMC :

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


TITLE :

CENTRAL PANEL MOUNTED


INSTRUMENT

LOCAL PANEL INSTRUMENT

REAR CENTRAL PANEL


MOUNTED INSTRUMENT

PIPING & INSTRUMENTATION DIAGRAM


TEMPLATE

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179

REAR LOCAL PANEL


INSTRUMENT

P&ID

CHKD APPD

REVISIONS

FIELD MOUNTED INSTRUMENT

HAND OPERATED VANES VALVE


VERTICAL SUSPENDED PUMP

HVG

HVG

PT. SMART Tbk.

FUNCTIONAL SYMBOLS

VANE CONTROL VALVE

EXPONENTIAL

HVG

ISSUE FOR BASIC DESIGN (POST-HAZOP)

ACCESSIBLE TO OPERATOR.

INTERLOCK FUNCTION (PLC).

ISSUE FOR TENDER

CLIENT :

BIAS

CONVERTER

REV.

n
19

HAND OPERATED VALVE


A

INTEGRAL

DIAPHRAGAM

PILOT OPERATED
SAFETY VALVE

INSULATION / TRACING TYPE


IH
IC
PP
IT
IE
IJ
NI

REMOTE TRANSMISSION UNIT

FOUR WAY VALVE

SAFETY VALVE NUMBER

SOFTWARE CALCULATION BOX.

STOP CHECK VALVE

ORIFICE CODE, LETTER


OUTLET SIZE, INCHES

RUNNING LIGHT (DCS)

IN LINE INSTRUMENT
(SIGHT GLASS, MASS FLOW
METER ETC.)

PSV
1101

RUNNING LIGHT
(LOCAL PANEL)

PUMPS

VENTURI METER

2J3
01

RUNNING LIGHT (PANEL)

SAMPLE CONNECTION
AIR PURGE
STEAM PURGE
AERATION AIR
AERATION STEAM
AREATION GAS
NITROGEN PURGE

TA1179-D-5212-1000

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1001
A

NOT TO SCALE

NOTES :

JETTY

PUBLIC PIPERACK

PUBLIC PIPERACK

SMART SITE

1. UTILITY STATION AT JETTY SHALL PROVIDE NITROGEN,


COMPRSSED AIR, AND DOMESTIC WATER.
2. SHUT DOWN VALVE (SDV) SHALL BE FAIL CLOSE (FC).

NITROGEN
-

3. HANDSWITCH OF SDV SHALL CLOSE VALVES AND FOR BIODIESEL


AND CRUDE GLYCERIN, STOP EXPORT PUMPS P-3102 A/B RESP. P2403 A/B.

4. DRIVING MEDIUM FOR PIGGING OF BIODIESEL AND METHANOL


LINES SHALL BE NITROGEN.

COMPRESSED AIR
-

5. DRIVING MEDIUM FOR PIGGING OF CRUDE GLYCERIN LINES


SHALL BE COMPRESSED AIR.
6. ALL PIGGING OPERATIONS SHALL BE FROM JETTY TO TANKFARM
AREA.

DOMESTIC WATER
-

7. LOCATION OF PIG LAUNCHER / RECEIVERS TO BE CONFIRMED.


8. PERMANENT NITROGEN CONNECTION FOR LINE FLUSHING
(BIODIESEL AND METHANOL).
U.S.

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

NOTE1

9. PERMANENT COMPRESSED AIR CONNECTION FOR LINE


FLUSHING (CRUDE GLYCERINE).
10. INDICATED SCOPE, FROM PUBLIC PIPERACK UP TO THE JETTY IS
FOR INFORMATION ONLY, AND NOT PART OF CURRENT SCOPE.

PI
12001

PI
12011

N2

NOTE8
N2

H-1201

JETTY SCOPE ON HOLD, PENDING


MANAGEMENT DECISION

PIG.SIG.
12011

PIG LAUNCHER/
RECEIVER PL/PR-1202

8 "- 12 - 0101 -A001 -NI

METHANOL
TA1179-D-5212-1007

PL/PR-1201
3 "- 12 - 0106 - A001 - NI

8 "- 12 - 0102 -A001 -NI

DRIP TRAY

TYPICAL XV (ON/OFF VALVE):

ZAHH

NOTE 3
PI
31001

HS

PI
31191

N2

NOTE8

HS

N2

H-3101

PIG.SIG.
31191

8 "- 31 - 0105 -A001 -NI

PIG LAUNCHER/
RECEIVER PL/PR-3102
BIODIESEL
TA1179-D-5212-1027

PL/PR-3101
8 "- 31 - 2712 -A001 -NI

3 "- 31 - 0107 - A001 -NI

TRIP
EXPORT
PUMP

ZSC

ZSO

SDV

DRIP TRAY

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

6"
6 "- 24 - 2916 - B001 -NI

PI
24091

N2
PIG.SIG.
24091
PI
24001

PL/PR-2401
6"
6 "- 24 - 0104 - B001 -NI

NOTE9

H-2401

CA

6"
6 "- 24 - 0103 - B001 -NI

DESCRIPTION

CRUDE GLYCERIN
TA1179-D-5212-1029

PMC :

PIG LAUNCHER/
RECEIVER PL/PR-2402

CONSULTANT :

CRUDE GLYCERIN
TA1179-D-5212-1016

ROYAL HASKONINGDHV

SMART MARUNDA BIODIESEL PLANT


TITLE :

PIPING & INSTRUMENTATION DIAGRAM


BD1 PRODUCT JETTY

SLOPE
SUMP
NOT IN SCOPE

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179

CONTRACTOR

P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

PROJECT :

CURBED AREA

DATE

PT. SMART Tbk.

DRIP TRAY

CHKD APPD

REVISIONS

CLIENT :

CRUDE GLYCERIN
EXPORT PUMPS
P-2403 A&B

3 "- 24 - 0108 - B001 - NI

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

TA1179-D-5212-1001

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1002
A

NOT TO SCALE

NOTES :
1. CHEMICAL TANKER UNLOADING AREA IS SHELTERED AND
BUNDED.
2. LOADING HOSE MATERIAL SHALL BE SUITABLE FOR HANDLING OF
CHEMICALS, AND HOSE SHALL BE EQUIPPED WITH SELF SEALING
COUPLING.

4. CHECK VALVE SHALL BE SWING TYPE DUE TO POTENTIAL FOR


CLOGGING.
5. TRUCK UNLOADING PUMPS SHALL BE SELF PRIMING TYPE.
6. UTILITY STATION AT CHEMICAL UNLOADING AREA SHALL
CONTAIN NITROGEN, COMPRESSED AIR, DOMESTIC WATER AND
LOW PRESSURE STEAM.
7. NITROGEN CONNECTIONS FOR LINE FLUSHING TO TOP OF PIPE
WITH QUICK COUPLING.
8. FLOW SWITCH SHALL STOP TRUCK UNLOADING PUMP WHEN
DONE, UPON DETECTION OF NO FLOW. TIME DELAY SHALL BE SET
TO ALLOW START OF PUMP.

NITROGEN
-

6
9. SAFETY SHOWER + EYE WASH SHALL BE LOCATED NEAR
CHEMICAL TRUCK UNLOADING AREA.

COMPRESSED AIR
-

10. PUMPS FORESEEN WITH TEMPERATURE SAFETY SWITCH, TO


PROTECT MOTOR FROM DAMAGE AT BLOCKED INLET OR OUTLET.

DOMESTIC WATER
LOW PRESSURE STEAM
FAULT
ALARM

XL
61031

RUNNING
LIGHT

13. ESD PUSH BUTTON WILL STOP ALL PUMPS IN UNLOADING AREA
(B1).

I
START/
STOP

HS
61031

01
TSH
61031

PDI
61031

14. DUMMY HOSE COUPLING, WHEN FLEXIBLE HOSE IS NOT IN USE.

PI
61031
FSI

11. CONCRETE FLOOR SHALL BE FORESEEN WITH CORROSION


RESISTANT LINING, SUITABLE TO WITHSTAND HYDROCHLORIC
ACID, SODIUM HYDROXIDE AND SODIUM METHYLATE.
12. CHEMICAL UNLOADING HOSES SHALL BE CLEARLY IDENTIFIED
OR FORESEEN WITH DEDICATED CONNECTIONS TO AVOID
ACCIDENTAL WRONG LINE-UP.

XA
61031

XS
LOCAL/
REMOTE 61031

NOTE 4
44""- 61 - 0202 -A001 -NI

15. TRUCK UNOADING STATION SHALL BE SUITABLE FOR A


MAXIMUM TRUCK SIZE OF 30 M3 ISOTANKERS.

SODIUM METHYLATE
TANKS T-6101, T-6102

61031

4 "- 61 - 0201 -A001 -NI

16. TRUCKS SHALL BE SAMPLED PRIOR TO UNLOADING

SODIUM METHYLATE
TA1179-D-5212-1008

1/2

P-6101
SODIUM METHYLATE
UNLOADING PUMP
NOTE 3, 5, 10

FAULT
ALARM

XA
62041

XS
LOCAL/
REMOTE 62041

XL
62041

RUNNING
LIGHT
I

4
START/
STOP

HS
62041
TSH
62041

1/2"

1/2"

PI
62041
FSI

HYDROCHLORIC ACID
TANKS T-6201 T-6203

62041

NOTE 4

1/2"

1/2"

1/2"
1/2"

1/2"

01

PDI
62041

U.S.

1/2"

4 "- 62 - 0203 - E001 -NI

44""- 62 - 0204 - E001 -NI

HYDROCHLORIC ACID
UNLOADING PUMP
NOTE 5, 10

FAULT
ALARM

HYDROCHLORIC ACID
TA1179-D-5212-1009

P-6201

1/2

NOTE6

XA
63021

XS
LOCAL/
REMOTE 63021

XL
63021

RUNNING
LIGHT

3
I

ESD

START/
STOP

ESD

HS
63021

01
TSH
63021

PDI
63021

NOTE13

NOTE7

PI
63021
FSI

SODIUM HYDROXIDE
TANK T-6301

63021

NOTE 4

H-6101

44""- 63 - 0206 -A001 -NI

4 "- 63 - 0205 -A001 -NI

SODIUM HYDROXIDE
TA1179-D-5212-1010

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

P-6301

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

SODIUM HYDROXIDE
UNLOADING PUMP
NOTE 5, 10

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

1/2

NOTE2,12

NOTE7

H-6201

REV.

DESCRIPTION

NOTE3

XS
61031

NOTE2,12
FAULT
ALARM

XS
LOCAL/
REMOTE 64021

NOTE7

TANK TRUCK
(BY OTHERS)

TRUCK
GROUNDING

H-6301

XL
64021

NOTE2,12

PMC :

HS
64021

01
TSH
64021

NOTE7

PI
64021

CONSULTANT :

FSI

PHOSPHORIC ACID
TANK T-6401

64021

NOTE 4

H-6401

44""- 64 - 0208 - C001 -NI

4 "- 64 - 0207 - C001 -NI


NOTE2,12

NOTE11

NOTE14

SLOPE

RUNNING
LIGHT
I

START/
STOP
PDI
64021

DATE

PT. SMART Tbk.

XA
64021

CHKD APPD

REVISIONS

CLIENT :

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

3. SODIUM METHYLATE TRUCK UNLOADING PUMPS ARE


INTERLOCKED WITH GROUNDING CONNECTION; WHEN NOT
CONNECTED, TRUCK UNLOADING CANNOT TAKE PLACE.

CANOPY

SLOPE

ROYAL HASKONINGDHV

PHOSPHORIC ACID
TA1179-D-5212-1011

PROJECT :

SMART MARUNDA BIODIESEL PLANT

P-6401
PHOSPHORIC ACID
UNLOADING PUMP
NOTE 5, 10

TITLE :

NOTE11

PIPING & INSTRUMENTATION DIAGRAM


CHEMICAL TRUCK UNLOADING (B1) 1/2

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1002

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1003
A

NOT TO SCALE

NOTES :
1. PUMP SUPPLIED BY LIPICO (ONLY PUMP; PIPE AND FITTINGS BY
SMART).
2. SAMPLE CONNECTION ON PUMP DISCHARGE VENT LINE.
3. SWING TYPE CHECK VALVE DUE TO POTENTIAL FOR CLOGGING.
4. TIE-IN LOCATIONS AT EXISTING TANKFARM TO BE CONFIRMED.

EXISTING TANKFARM

RBDST
(EXISTING)
T-2101 / 2102 RBDPO
TANKS
RBDPO / RBDST
TA1179-D-5212-1012

5
6"
6 "- 21 - 0301 -A001 - IT

TI
0.3

NOTE 4

PRE-TREATMENT
PLANT (P1)
RBDPO
TA1179-D-5212-1004

4 "- 21 - 0402 - B001 - IT


FAULT
ALARM

RBDPO
(EXISTING)

TI
0.1

XA
10011

XS
LOCAL/
REMOTE 10011

XL
10011

RUNNING
LIGHT

4
I

HS
10011
TSH

PDI
10011

PI
10011

10011
FSI

NOTE 2

1/2

START/
STOP

NOTE 4

10011

NOTE 3

44""- 10 - 0305 - A001 - IT

6 "- 10 - 0304 - A001 - IT

PRE-TREATMENT
PLANT (P1)
REJECT CPO
TA1179-D-5212-1004

1/2

PU301 A

44""- 10 - 0308 -A001 - IT

6 "- 10 - 0303 -A001 - IT

CPO TRANSFER
PUMP
NOTE 1

3
PRE-TREATMENT
PLANT (P1)

4"
4 "- 10 - 0408 - A001 - IT

CPO TANK
(EXISTING)

TI
0.5

4 "- 10 - 0302 - A001 - IT

FAULT
ALARM

TI
0.2

4 "- 10 - 0309 - A001 - IT

XA
10021

XS
LOCAL/
REMOTE 10021

XL
10021

RBDPO / RBDST
TA1179-D-5212-1004

RUNNING
LIGHT
I

NOTE 4

START/
STOP

HS
10021
TSH

PDI
10021

PI
10021

10021

FSI

NOTE 2

1/2

NOTE 4

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

10021

DESCRIPTION

CLIENT :

4"
4 "- 10 - 0307 - A001 - IT

6 "- 10 - 0306 - A001 - IT

PRE-TREATMENT
PLANT (P1)
PFAD
TA1179-D-5212-1004

CHKD APPD

DATE

REVISIONS

NOTE 3

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

PT. SMART Tbk.

PU301 B
CPO TRANSFER
PUMP
NOTE 1

PMC :

2 "- 32 - 0403 - A001 - IT


CONSULTANT :

PFAD TANK
(EXISTING)

TI
0.4

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT

NOTE 4

TITLE :

PIPING & INSTRUMENTATION DIAGRAM


EXISTING TANKFARM

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1003

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1004
A

NOT TO SCALE

NOTES :
1. ISBL SCOPE IS PART OF VENDOR PACKAGES, SUPPLIED BY EITHER
LIPICO (P1, P3, P4) OR LURGI (P2).
2. LOCATION OF B/L VALVES SHALL BE BY PREFERENCE INSIDE
BUILDING, FOR ACCESSIBILTY REASONS.
3. PITCH GLYCERIN STARTS SOLIDIFYING AT 70-80 C; REQUIRES
STEAM TRACING BY SPIRAL TRACING TO MAINTAIN PRODUCT AT
SUFFICIENTLY HIGH TEMPERATURE.

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

TI
1.2

RBDPO TANKS T-2101,


T-2102

6
4 "- 21 - 0401 -A001 - NI

PHOSPHORIC ACID
TRANSFER PUMP P-6402

RBDPO
TA1179-D-5212-1012

TI
1.6

PHOSPHORIC ACID
TA1179-D-5212-1023

2 "- 64 - 2309 - C001 - NI

TI
1.3

2" X 1"

EXISTING RBDPO
TANKS
4 "- 21 - 0402 - B001 - IT

P1
PRE-TREATMENT PLANT (BY LIPICO)

RBDPO
TA1179-D-5212-1003

TI
1.5

EXISTING CPO TANKS

CPO
TA1179-D-5212-1003

44""- 10 - 0408 -A001 - IT

5" X 4"

TI
1.1

CPO TRANSFER
PUMPS PU301 A&B

REJECT CPO
TA1179-D-5212-1003

4 "- 10 - 0309 -A001 - IT


TI
1.4

EXISTING PFAD TANKS


2 "- 32 - 0403 -A001 - IT

PFAD
TA1179-D-5212-1003

SODIUM HYDROXIDE
TRANSFER PUMPS
516G10 A&B

3
TI
2.6

SODIUM HYDROXIDE
TA1179-D-5212-1039

2 "- 63 - 3907 -A001 - NI

PITCH GLYCERIN
TANKS T-3401, T-3402

TI
2.3

2" X 1 "
2 "- 34 - 0405 - C001 - IT

PITCH GLYCERIN
TA1179-D-5212-1022

TI
2.7

2 "- 25 - 0409 - B001 -NI

CRUDE GLYCERIN
TRANSFER PUMPS
P-2402 A&B
2

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

TI
2.1

P2
GLYCERIN REFINING PLANT (BY LURGI)

2" x 3"

CRUDE GLYCERIN
TA1179-D-5212-1029

2 "- 24 - 2907 - B001 - NI

DESCRIPTION

CLIENT :

3" x 2"
2 "- 25 - 0406 - B001 - NI

DATE

REVISIONS
2

PT. SMART Tbk.

YELLOW GLYCERIN
TANK T-2501

TI
2.4

CHKD APPD

YELLOW GLYCERIN
TA1179-D-5212-1017

PMC :

CONSULTANT :

YELLOW GLYCERIN
TRANSFER PUMP
P-2501

TI
2.2

YELLOW GLYCERIN
TA1179-D-5212-1030

REFINED GLYCERIN
DAY TANKS T-3301,
T-3302

TI
2.5
3" x 2"
2 "- 33 - 0407 - B001 - NI

ROYAL HASKONINGDHV

REFINED GLYCERIN
TA1179-D-5212-1018

PROJECT :

2 "- 25 - 3011 - B001 -NI

SMART MARUNDA BIODIESEL PLANT

TITLE :

PIPING & INSTRUMENTATION DIAGRAM

PRE-TREATMENT & GLYCERIN REF. PLANT (P1&P2)


PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1004

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1005
A

NOT TO SCALE

NOTES :
1. ISBL SCOPE IS PART OF VENDOR PACKAGES, SUPPLIED BY EITHER
LIPICO (P1, P3, P4) OR LURGI (P2).
2. LOCATION OF B/L VALVES SHALL BE BY PREFERENCE INSIDE
BUILDING, FOR ACCESSIBILTY REASONS.

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

TI
3.9

METHANOL TANKS
T-1201 & T-1202
2 "- 12 - 0501 -A001 -NI

METHANOL TRANSFER
PUMPS P-1201 A&B
METHANOL
TA1179-D-5212-1025

2 "- 12 - 2507 - A001 -NI

SODIUM METHYLATE
TA1179-D-5212-1025

2 "- 61 - 2514 - A001 -NI

2 "- 61 - 2515 - A001 -NI

6 "- 26 - 0507 - A001 -NI


2" X 1"

RBDPO
TA1179-D-5212-1026

4" x 6"

INT. BIODIESEL
TA1179-D-5212-1013

6 "- 26 - 0506 -A001 -NI

TI
3.19

TI
3.6

1" x 2"
2 "- 22 - 0512 - A001 -NI

4 "- 21 - 2606 - A001 - IT

TI
3.15

TI
3.7

FATTY MATTER TANK


T-3501
1" x 2"
2 "- 35 - 0508 - B001 - IT

2 "- 22 - 3309 - A001 -NI

SLOP GLYCERIN
TRANSFER PUMP
P-2301
SLOP GLYCERIN
TA1179-D-5212-1033

INT. BIODIESEL
TA1179-D-5212-1006

INTERMEDIATE
BIODIESEL TANKS
T-2601 & T-2602

TI
3.14

2" X "

SLOP BIODIESEL
TRANSFER PUMP
P-2201
SLOP BIODIESEL
TA1179-D-5212-1033

P3
BIODIESEL PLANT (BY LIPICO)

TI
3.5

2 "- 63 - 2407 - A001 -NI


2"

SODIUM METHYLATE
TA1179-D-5212-1008

COLD FILTRATION
PLANT (P4)

TI
3.4

2 "- 64 - 2308 - C001 -NI

HYDROCHLORIC ACID
TA1179-D-5212-1009

SODIUM METHYLATE
TANKS T-6101 & T-6102
2 "- 61 - 0505 -A001 -NI

RBDPO TRANSFER
PUMPS PU3301 A&B
3

TI
3.13

2" X 1"

SODIUM HYDROXIDE
TRANSFER PUMPS
PU4222 A&B
SODIUM HYDROXIDE
TA1179-D-5212-1024

2 "- 62 - 0504 -D003 - IE

2" X 1"

2 "- 62 - 2307 -E001 -NI

PHOSPHORIC ACID
TA1179-D-5212-1011

HYDROCHLORIC ACID
TANKS T-6201, T-6202
& T-6203

TI
3.12

TI
3.3

SODIUM HYDROXIDE
TA1179-D-5212-1010

PHOSPHORIC ACID
TANK T-6401
2 "- 64 - 0503 - B001 - IE

TI
3.20

PHOSPHORIC ACID
TRANSFER PUMP
P-6402
PHOSPHORIC ACID
TA1179-D-5212-1023

TI
3.11

2" X 1"

HYDROCHLORIC ACID
TRANSFER PUMPS
PU4211 A&B
HYDROCHLORIC ACID
TA1179-D-5212-1023

2 "- 63 - 0502 -A001 -NI

TI
3.2

SODIUM METHYLATE
TRANSFER PUMPS
PU3322 A, B & C
5

SODIUM HYDROXIDE
TANK T-6301

2" X 2"

SODIUM METHYLATE
TRANSFER PUMPS
PU3322 A, B & C
SODIUM METHYLATE
TA1179-D-5212-1025

TI
3.10

TI
3.1

METHANOL
TA1179-D-5212-1007

TI
3.16

TI
3.8

FATTY MATTER
TA1179-D-5212-1014

SLOP BIODIESEL TANK


T-2201
4 "- 22 - 0509 -A001 -NI

2 "- 23 - 3310 - B001 - IT

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

SLOP BIODIESEL
TA1179-D-5212-1020

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

2" X 1"

PT. SMART Tbk.


TI
3.17

PMC :

SLOP GLYCERIN TANK


T-2301
1" x 2"
2 "- 23 - 0510 - B001 - IT

SLOP GLYCERIN
TA1179-D-5212-1021
CONSULTANT :

ROYAL HASKONINGDHV

TI
3.18

CRUDE GLYCERIN
TANKS T-2401 & T-2402
1" x 2"
2 "- 24 - 0511 - B001 -NI

PROJECT :

CRUDE GLYCERIN
TA1179-D-5212-1016

SMART MARUNDA BIODIESEL PLANT

TITLE :

PIPING & INSTRUMENTATION DIAGRAM


BIODIESEL PLANT (P3)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1005

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1006
A

NOT TO SCALE

NOTES :
1. ISBL SCOPE IS PART OF VENDOR PACKAGES, SUPPLIED BY EITHER
LIPICO (P1, P3, P4) OR LURGI (P2).

P4
COLD FILTRATION PLANT (BY LIPICO)

4" X 6"

6" X 4"

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

2. LOCATION OF B/L VALVES SHALL BE BY PREFERENCE INSIDE


BUILDING, FOR ACCESSIBILTY REASONS.

BIODIESEL TANKS
T-3101 T-3104

BIODIESEL PLANT (P3)


INT. BIODIESEL
TA1179-D-5212-1005

6 "- 26 - 0507 -A001 -NI

BIODIESEL
TA1179-D-5212-1015

6 "- 31 - 0601 - A001 -NI

SLUDGE BIODIESEL
RETURN FROM PUMP
P-3101 A/B/C

SLUDGE BIODIESEL
TA1179-D-5212-1028

3 "- 31 - 2813 -A001 -NI

3" X 6"

INTERMEDIATE
BIODIESEL TRANSFER
PUMPS PU6611 A&B
INT. BIODIESEL
TA1179-D-5212-1026

66""- 26 - 2611 -A001 -NI

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


PMC :

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

PIPING & INSTRUMENTATION DIAGRAM


COLD FILTRATION PLANT (P4)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1006

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1007
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. PV VALVE.

METHANOL FROM
JETTY
METHANOL
TA1179-D-5212-1001

3. IN CASE OF BLANKETED TANK, EMERGENCY HATCH SHALL BE


PROVIDED TO AVOID TANK DAMAGE DUE TO OVERPRESSURE.
8 "- 12 - 0102 -A001 -NI

5. TANK FOAMBOX NOZZLE FOR FIRE FIGHTING; FOR DETAILS REFER


TO FIREFIGHTING DESIGN DOCUMENTS.

METHANOL PUMPBACK FROM


BIODIESEL PLANT (P3)
METHANOL
TA1179-D-5212-1005

6. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF


NEEDED.
2 "- 12 - 0501 -A001 -NI

7. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN


CONTROL ROOM.
8. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION
WILL INITIATE PUMP SHUTDOWN.

METHANOL TRANSFER
PUMPS PU3321 A&B
METHANOL
TA1179-D-5212-1024

4. DIPPING HATCH + STILLING WELL AND DATUM PLATE.

9. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP


SHUTDOWN.

2 "- 12 - 2525 -A001 -NI

10. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.


PVV
12011

NOTE 2, 11

REF. DWG M-00.014, 054


FOR DETAILS ON TANK
NITROGEN
BLANKETING SYSTEM

ATM

ATM

NOTE 3
RN03, 04
8"
RN31

NOTE 4

RM01
20

RN32

HH

LZA
12011

LZSHH
12011

LI

LIA

12011

12011

H
L

12. AMOUNT AND TYPE OF FOAM BOXES REQUIRED MAY DIFFER WITH
SIZE AND TYPE OF TANK. REQUIREMENTS OF NFPA 11 SHALL BE MET.

I
LI
12011

LT
12011

13. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

NOTE 10

NOTE 1

14. TANK FIRE FIGHTING PROVISIONS INCL. SPRINKLER COOLING AND


FOAM SUPPLY SHALL BE ACCORDING TO NFPA REQUIREMENTS.

RN08
3

RN06
6

NOTE 7

RN05
8"

RN33*

MH

11. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API


2000.

NOTE 8

15. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

RN07
6

RN20
8"

16. PRODUCT INLET AND RECIRCULATION VIA TANK TOP, WITH J-TUBE
+ IMPINGEMENT PLATE TO AVOID SPLASHING AND STATIC BUILD-UP
IN PRODUCT.

REF. DWG M-00.059, 019


FOR DETAILS OF
FIRE FIGHTING SYSTEM

5
SN20,
21, 22

17. CLOSED MOV INTERLOCKED WITH PUMP P-1201 A/B; IF MOV


CLOSED, PUMP CANNNOT START; IF PUMP TRIPS, MOV CLOSES.

FOAM BOX NOZZLE

NOTE 16
NOTE 5, 12, 24

T-1201
METHANOL

SN10
3

MANHOLE
WITH DAVIT

LSLL
12011

NOTE 9

3
I

MOV
12011

SN02
2"
2

MH

8 "- 12 - 0701 -A001 -NI

2 "- 12 - 0703 -A001 -NI


SM01 - 24
SM01 - 24
SM02 - 24"

WATER
DRAWOFF

SN04
2"
2

NOTE 17

SN03
2"
NOTE 6

3
BS01

NOTE 15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

DATE

PT. SMART Tbk.

T-1202
METHANOL

8 "- 12 - 0702 -A001 -NI

CHKD APPD

REVISIONS

CLIENT :

2 "- 12 - 0704 - A001 -NI


PMC :

CONSULTANT :

ROYAL HASKONINGDHV

PI
12061

N2
PIG.SIG.
12061

PL/PR-1202
1

PROJECT :

2 "- 12 - 0707 -A001 -NI

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

SMART MARUNDA BIODIESEL PLANT


TITLE :

METHANOL TRANSFER
PUMPS P-1201 A/B
2 "- 12 - 0705 - A001 -NI

PIPING & INSTRUMENTATION DIAGRAM


METHANOL TANKS (T2)

METHANOL
TA1179-D-5212-1024

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179

2 "- 12 - 0706 -A001 - NI

P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1007

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1008
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. PV VALVE.

SODIUM METHYLATE
UNLOADING PUMP
P-6101
4"
4 "- 61 - 0202 -A001 -NI

5. TANK FOAMBOX NOZZLE FOR FIRE FIGHTING; FOR DETAILS REFER


TO FIREFIGHTING DESIGN DOCUMENTS.

DOMESTIC WATER
2 "- 61 - 2524 -A001 -NI

4. DIPPING HATCH + DATUM PLATE.

COMPRESSED AIR
-

SODIUM METHYLATE
RETURN FROM PUMPS
PU3322 A, B & C
SODIUM METHYLATE
TA1179-D-5212-1025

3. IN CASE OF BLANKETED TANK, EMERGENCY HATCH SHALL BE


PROVIDED TO AVOID TANK DAMAGE DUE TO OVERPRESSURE.

NITROGEN
-

LOW PRESSURE STEAM


-

6. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF


NEEDED.
7. PRODUCT INLET VIA TANK TOP, WITH J-TUBE AND IMPINGEMENT
PLATE, TO AVOID SPASHING AND STATIC BUILD-UP IN PRODUCT.
8. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN
CONTROL ROOM.
9. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION
WILL INITIATE PUMP SHUTDOWN.
10. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.

PVV
61011

NOTE 2, 12

REF. DWG M-00.014, 054


FOR DETAILS ON TANK
NITROGEN
BLANKETING SYSTEM

ATM

ATM

NOTE 3
RN03, 04
8"
RN31

NOTE 4

HH

LZA
61011

LZSHH
61011

LI

LIA

61011

61011

LT
61011

LI
61011

11. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.

NOTE 8
L

12. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API


2000.
13. AMOUNT AND TYPE OF FOAM BOXES REQUIRED MAY DIFFER WITH
SIZE AND TYPE OF TANK. REQUIREMENTS OF NFPA 11 SHALL BE MET.

I
01

NOTE 11

NOTE 1

14. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

RN05
8"
RN08
3

RN06
6

15. TANK FIRE FIGHTING PROVISIONS INCL. SPRINKLER COOLING AND


FOAM SUPPLY SHALL BE ACCORDING TO NFPA REQUIREMENTS.
RN07
6

16. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

RN20
4"

REF. DWG M-00.059, 019


FOR DETAILS OF
FIRE FIGHTING SYSTEM

5
SN20

17. UTILITY STATION IN TANK BUNDED AREA SHALL PROVIDE


NITROGEN, COMPRSSED AIR, DOMESTIC WATER AND LOW PRESSURE 5
STEAM.

FOAM BOX NOZZLE

NOTE 17

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

U.S.
NOTE 5, 13

1/2"

RM01
20

RN32
RN33*

MH

NOTE 9

1/2"

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

SODIUM METHYLATE
TA1179-D-5212-1002

NOTE17

T-6101
SODIUM METHYLATE

SN10
3

MANHOLE
WITH DAVIT

LSLL
61011

MOV
61011

SN02
2"
2

MH

4 "- 61 - 0801 -A001 -NI


NO

SN04
2"
2

3
I
01

2 "- 61 - 0803 -A001 -NI


SM01 - 24
SM01 - 24
SM02 - 24"

WATER
DRAWOFF

NOTE 10

SN03
2"
NOTE 6

3
BS01

NOTE 16

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

4 "- 61 - 0802 -A001 -NI

CHKD APPD

DATE

REVISIONS

CLIENT :

T-6102
SODIUM
METHYLATE

DESCRIPTION

PT. SMART Tbk.


PMC :
2 "- 61 - 0804 - A001 -NI

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

SODIUM METHYLATE
TRANSFER PUMPS
PU3322 A, B & C
2 "- 61 - 0805 - A001 -NI

PIPING & INSTRUMENTATION DIAGRAM


SODIUM METHYLATE TANKS (T2)

SODIUM METHYLATE
TA1179-D-5212-1025

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1008

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1009
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. PV VALVE.

HYDROCHLORIC ACID
UNLOADING PUMP
P-6201

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

HYDROCHLORIC ACID
TA1179-D-5212-1002

3. DIPPING HATCH + DATUM PLATE.


4. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF
NEEDED.

44""- 62 - 0204 - E001 -NI

HYDROCHLORIC ACID
FROM TRANSFER
PUMP PU4211 A&B
HYDROCHLORIC ACID
TA1179-D-5212-1023

5. PRODUCT INLET VIA TANK TOP, WITH DIP-TUBE + WEEP HOLE, TO


AVOID SPLASHING AND PRODUCT SYPHONING.
6. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN
CONTROL ROOM.

2 "- 62 - 2311 - E001 -NI

7. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION


WILL INITIATE PUMP SHUTDOWN.
8. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.

4 "- 62 - 0908 - E001 -NI

9. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.


10. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API
2000.
PVV
62011

6
NOTE 7
LZA
62011

ATM

ATM

NOTE 3

LIA
62011

H
L

LT
62011

LI
62011

13. ALL STEEL ITEMS IN HCL BUNDED AREA SHALL BE FORESEEN


WITH ACID RESISTANT COATING.

NOTE 9

NOTE 1

14. IN CASE OF BLANKETED TANK, EMERGENCY HATCH SHALL BE


PROVIDED TO AVOID TANK DAMAGE DUE TO OVERPRESSURE.

RN05
RN04
8"
4

EDUCTOR

RN08
3"

RM02
20

RN06
6

12. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

M-6201
HCL SCRUBBER (VENDOR PACKAGE)

NOTE 14
RN03, 04
8"

RN22
4

LI
62011

NOTE 15

LZSHH
62011

RN21
4

11. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

NOTE 7
NOTE 2, 10

HH

ATM

15. RECIRCULATING SCRUBBER (VENDOR PACKAGE) FOR


NEUTRALISATION OF VENT GAS FROM TANKS.

4 "- 62 - 0911 - E001 -NI


RN07
6

RN20
20

S-6201
HCL
SCRUBBER

NOTE 5

NOTE 5, 12, 24

T-6201
HYDROCHLORIC ACID

SN10
3

MANHOLE
WITH DAVIT

62011

NOTE 8

SN02
2

MH

44""- 62 - 0901 - E001 -NI

LSLL

2 "- 62 - 0904 - E001 -NI


SM01 - 24

WATER
DRAWOFF

NOTE 20

SN04
2

SN03
2"

NO SLOPE,
NO SUMP

NOTE 4

NOTE 12

NOTE 25

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

44""- 62 - 0902 - E001 -NI

4 "- 62 - 0909 - E001 -NI

PMC :

CONSULTANT :
4 "- 62 - 0910 - E001 -NI

ROYAL HASKONINGDHV
PROJECT :
2 "- 62 - 0906 - E001 -NI

SMART MARUNDA BIODIESEL PLANT


TITLE :

HCL TRANSFER
PUMPS PU4211 A&B
2 "- 62 - 0907 - E001 -NI

PIPING & INSTRUMENTATION DIAGRAM


HYDROCHLORIC ACID TANK (T1)

HCL
TA1179-D-5212-1023

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

PT. SMART Tbk.

DATE

2 "- 62 - 0905 - E001 -NI

T-6203
HYDROCHLORIC
ACID

44""- 62 - 0903 - E001 -NI

CHKD APPD

REVISIONS

CLIENT :

T-6202
HYDROCHLORIC
ACID

DESCRIPTION

TA1179-D-5212-1009

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1010
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. VENT + BIRDSCREEN.

SODIUM HYDROXIDE
UNLOADING PUMP
P-6301

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

SODIUM HYDROXIDE
TA1179-D-5212-1002

3. DIPPING HATCH + DATUM PLATE.


4. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF
NEEDED.

44""- 63 - 0206 -A001 -NI

SODIUM HYDROXIDE
TRANSFER PUMP
PU4222 A&B
SODIUM HYDROXIDE
TA1179-D-5212-1024

5. PRODUCT INLET VIA TANK TOP, WITH J-TUBE AND IMPINGEMENT


PLATE TO AVOID SPLASHING AND STATIC BUILD-UP IN PRODUCT.
6. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN
CONTROL ROOM.

2 "- 63 - 2409 -A001 -NI

7. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION


WILL INITIATE PUMP SHUTDOWN.
8. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.
9. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.
10. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API
2000.
6
NOTE 7
LZA

HH

NOTE 2, 10

63011

LI

LIA

63011

63011

11. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

H
L

12. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

ATM
LZSHH
63011

LI
63011

LT
63011

RN01, 02
6"

NOTE 6

NOTE 9

NOTE 1

NOTE 3
RN08
3

MH
RM01
20

RN07
6

RN06
6

RN20
4"

NOTE 5

T-6301
SODIUM HYDROXIDE

SN10
3

MANHOLE
WITH DAVIT

SN04
2"
2

NOTE 8

2 "- 63 - 1002 - A001 -NI


SM01 - 24

WATER
DRAWOFF

63011

SN02
2"
2

MH

4 "- 63 - 1001 - A001 -NI

LSLL

SN03
2"
NOTE 4

3
BS01

NOTE 12

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


PMC :

CONSULTANT :

ROYAL HASKONINGDHV
SODIUM HYDROXIDE
TRANSFER PUMPS
516G10 A & B
2 "- 63 - 1004 - A001 - NI

PROJECT :

SMART MARUNDA BIODIESEL PLANT

SODIUM HYDROXIDE
TA1179-D-5212-1039

TITLE :

SODIUM HYDROXIDE
TRANSFER PUMPS
PU4222 A&B
2 "- 63 - 1003 - A001 - NI

PIPING & INSTRUMENTATION DIAGRAM


SODIUM HYDROXIDE TANK (T1)

SODIUM HYDROXIDE
TA1179-D-5212-1024

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1010

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1011
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2.VENT + BIRDSCREEN.

PHOSPHORIC ACID
UNLOADING PUMP
P-6401

3. DIPPING HATCH + DATUM PLATE.


NITROGEN
-

44""- 64 - 0208 - C001 -NI

PHOSPHORIC ACID
FROM TRANSFER
PUMP P-6402
PHOSPHORIC ACID
TA1179-D-5212-1023

4. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF


NEEDED.

COMPRESSED AIR
-

2 "- 64 - 2313 - C001 -NI

5. PRODUCT INLET VIA TANK TOP, WITH J-TUBE AND IMPINGEMENT


PLATE TO AVOID SPLASHING AND STATIC BUILD-UP IN PRODUCT.

DOMESTIC WATER
LOW PRESSURE STEAM
-

6. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN


CONTROL ROOM.
7. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION
WILL INITIATE PUMP SHUTDOWN.
8. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.
9. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.
10. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API
2000.

6
NOTE 7
HH

LZA

NOTE 2, 10

64011

LI

LIA

64011

64011

LT
64011

LI
64011

11. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

H
L

12. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

ATM
LZSHH
64011

RN01, 02
6"

NOTE 6

13. UTILITY STATION IN TANK BUNDED AREA SHALL PROVIDE


NITROGEN, COMPRSSED AIR, DOMESTIC WATER AND LOW PRESSURE
STEAM.

NOTE 9

NOTE 1

NOTE 3
RN08
3

MH
RM01
20

RN07
6

RN06
6

RN20
4"

NOTE 5

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

U.S.

1/2"

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

PHOSPHORIC ACID
TA1179-D-5212-1002

NOTE13

T-6401
PHOSPHORIC ACID

SN10
3

MANHOLE
WITH DAVIT

SN04
2"
2

NOTE 8

2 "- 64 - 1102 - C001 -NI


SM01 - 24

WATER
DRAWOFF

64011

SN02
2"
2

MH

4 "- 64 - 1101 -C001 -NI

LSLL

SN03
2"
NOTE 4

3
BS01

NOTE 12

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


PMC :

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

PHOSPHORIC ACID
TRANSFER PUMP
P-6402
2 "- 64 - 1103 - C001 -NI

PIPING & INSTRUMENTATION DIAGRAM


PHOSPHORIC ACID TANK (T1)

PHOSPHORIC ACID
TA1179-D-5212-1023

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1011

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1012
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. VENT + BIRDSCREEN.

RBDPO FROM PRETREATMENT PLANT


(P1)

3. DIPPING HATCH AND DATUM PLATE.


NITROGEN
-

4 "- 21 - 0401 -A001 -NI

EXISTING RBDPO /
RBDST TANKS
RBDPO / RBDST
TA1179-D-5212-1003

6"
6 "- 21 - 0301 -A001 - IT

5. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN


CONTROL ROOM.

DOMESTIC WATER
LOW PRESSURE STEAM
-

RECYCLE FROM
RBDPO TRANSFER
PUMPS PU3301 A&B
RBDPO / RBDST
TA1179-D-5212-1026

4. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF


NEEDED.

COMPRESSED AIR
-

6. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION


WILL INITIATE PUMP SHUTDOWN.
7. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.
8. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.

6 "- 21 - 2605 -A001 - IT

9. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API


2000.
10. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO
GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.
6
NOTE 6
LZA

HH

NOTE 2, 9

21011

LI

LIA

21011

21011

LT
21011

LI
21011

11. NUMBER OF INLET AND OUTLET NOZZLES FOR HEATING COIL


DEPENDS ON THE REQUIRED HEATING CAPACITY PER TANK. REFER
TO UTILITY DRAWING M-00.070 (TANK DETAIL) FOR DETAILS OF TANK
HEATING ARRANGEMENT.

NOTE 5
L

ATM

12. HEAT CONSERVATION INSULATION TO SHELL AND PERSONNEL


PROTECTION INSULATION TO ROOF.

LZSHH
21011

NOTE 8

13. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

NOTE 12

RN01, 02
8"

NOTE 1

PP

NOTE 3

RM01
20

14. SIDE ENTRY MIXER TO ASSURE HOMOGENEUS PRODUCT QUALITY


AND FACILITATE PRODUCT HEATING.

RN08
3

MH

RN07
6"

RN06
6

15. UTILITY STATION IN TANK BUNDED AREA SHALL PROVIDE


NITROGEN, COMPRSSED AIR, DOMESTIC WATER AND LOW PRESSURE
STEAM.

RN20
6"

16. SIDE ENTRY AGITATOR TO BE FORESEEN WITH PERMISSIVE


INTERLOCK, TO ALLOW RUN ONLY IF PRODUCT LEVEL IS ABOVE LOW
LEVEL, AND TO SHUTOFF AGITATOR ON TRIGGER OF LOW LEVEL
SWITCH.

IH

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

U.S.
NOTE 12

1/2"

NOTE 12

1/2"

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

RBDPO
TA1179-D-5212-1004

NOTE15

T-2101
SN34
6"

RBDPO

HS
12011

NOTE 14,16

SN11
2"

HS
21011

TT
21011

6"
6 "- 21 - 1201 -A001 - IT

REF. DWG M-00.XXX


FOR DETAILS ON TANK HEATING SYSTEM

SN10
3

MANHOLE
WITH DAVIT

SN30, 31

LSLL
21011

NOTE 7

NOTE 11
SN02
4"
2

MH

SN32, 33

4 "- 21 - 1203 - A001 - IT


SM01 - 24

WATER
DRAWOFF

SN04
2"
2

SN03
2"
NOTE 4

3
BS01

NOTE 13

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

PT. SMART Tbk.

T-2102
RBDPO

6"
6 "- 21 - 1202 -A001 - IT

DATE

REVISIONS

CLIENT :

CHKD APPD

4 "- 21 - 1204 - A001 - IT


PMC :

CONSULTANT :

ROYAL HASKONINGDHV
RBDPO TRANSFER
PUMPS PU3301 A&B
4 "- 21 - 1205 - A001 - IT

PROJECT :

SMART MARUNDA BIODIESEL PLANT

RBDPO
TA1179-D-5212-1026

TITLE :

RBDPO TRANSFER
PUMPS PU3301 A&B
4 "- 21 - 1206 - A001 - IT

PIPING & INSTRUMENTATION DIAGRAM


RBDPO TANKS (T3)

RBDPO
TA1179-D-5212-1026

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1012

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1013
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. PV VALVE.
3. DIPPING HATCH + DATUM PLATE.

BIODIESEL PLANT (P3)


7

INT. BIODIESEL
TA1179-D-5212-1005

4. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF


NEEDED.

6 "- 26 - 0506 -A001 -NI

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

5. J-TUBE + IMPINGEMENT PLATE FOR TOP INLET.


6. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN
CONTROL ROOM.
7. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION
WILL INITIATE PUMP SHUTDOWN; STOP OF DESMET PUMPS 390P5 AND
1000P6 A/B.
8. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.
9. IN CASE OF BLANKETED TANK, EMERGENCY HATCH SHALL BE
PROVIDED TO AVOID TANK DAMAGE DUE TO OVERPRESSURE.
10. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.
PVV
26011

NOTE 2, 11

REF. DWG M-00.014, 054


FOR DETAILS ON TANK
NITROGEN
BLANKETING SYSTEM

ATM

ATM

NOTE 9
RN03, 04
8"
RN31

NOTE 3

RM01
20

RN32

HH

LZA
26011

LZSHH
26011

LI

LIA

26011

26011

LT
26011

LI
26011

NOTE 6
L

12. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.
13. TANK FIRE FIGHTING PROVISIONS INCL. SPRINKLER COOLING AND
FOAM SUPPLY SHALL BE ACCORDING TO NFPA REQUIREMENTS.

NOTE 10

NOTE 1

14. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

RN05
8"
RN08
3

RN33*

MH

11. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API


2000.

NOTE 7

RN06
6

RN07
6

RN20
6"

NOTE 5

T-2601
INTERMEDIATE BIODIESEL

SN10
3

MANHOLE
WITH DAVIT

SN04
4"
2

NOTE 8

6 "- 26 - 1303 - A001 -NI


SM01 - 24
SM01 - 24
SM02 - 24"

WATER
DRAWOFF

26011

SN02
6"
2

MH

6 "- 26 - 1301 - A001 -NI

LSLL

SN03
4"
2"
NOTE 4

3
BS01

NOTE 14

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

6 "- 26 - 1302 - A001 -NI

CHKD APPD

DATE

REVISIONS

CLIENT :

T-2602
INTERMEDIATE
BIODIESEL

DESCRIPTION

PT. SMART Tbk.


6 "- 26 - 1304 - A001 -NI
PMC :

CONSULTANT :

ROYAL HASKONINGDHV
INTERMEDIATE
BIODIESEL TRANSFER
PUMPS PU6611 A&B
6 "- 26 - 1305 - A001 - NI

PROJECT :

SMART MARUNDA BIODIESEL PLANT

INT. BIODIESEL
TA1179-D-5212-1026

TITLE :

INTERMEDIATE
BIODIESEL TRANSFER
PUMPS PU6611 A&B
6 "- 26 - 1306 - A001 - NI

PIPING & INSTRUMENTATION DIAGRAM


INTERMEDIATE BIODIESEL TANKS (T3)

INT. BIODIESEL
TA1179-D-5212-1026

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1013

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1014
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. VENT + BIRDSCREEN.
3. DIPPING HATCH + DATUM PLATE.

BIODIESEL PLANT (P3)


7

FATTY MATTER
TA1179-D-5212-1005

4. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF


NEEDED.

2 "- 35 - 0508 - B001 - IT


2"

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

5. J-TUBE + IMPINGEMENT PLATE FOR TOP INLET.


6. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN
CONTROL ROOM.
7. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION
WILL INITIATE PUMP SHUTDOWN.
8. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.
9. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.
10. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API
2000.
11. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO
GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

6
NOTE 7
LZA

HH

NOTE 2, 10

35011

LI

LIA

35011

35011

NOTE 6

12. NUMBER OF INLET AND OUTLET NOZZLES FOR HEATING COIL


DEPENDS ON THE REQUIRED HEATING CAPACITY PER TANK. REFER
TO UTILITY DRAWING M-00.070 (TANK DETAIL) FOR DETAILS OF TANK
HEATING ARRANGEMENT.

NOTE 9

13. TANK FIRE FIGHTING PROVISIONS INCL. SPRINKLER COOLING AND


FOAM SUPPLY SHALL BE ACCORDING TO NFPA REQUIREMENTS.

ATM
LZSHH
35011

LI
35011

LT
35011

RN01, 02
6"

NOTE 1

14. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

NOTE 3
RN08
3

MH
RM01
20

RN07
6"

RN06
6

RN20
2"

NOTE 5

T-3501
FATTY MATTER
SN11
2"

TT
35011

2 "- 35 - 1401 - B001 - IT


2"

REF. DWG M-00.XXX


FOR DETAILS ON TANK HEATING SYSTEM

SN10
3

MANHOLE
WITH DAVIT

SN30, 31

LSLL
35011

NOTE 8

NOTE 12
SN02
4"
2

MH

SN32, 33

4 "- 35 - 1402 - B001 - IT


SM01 - 24

WATER
DRAWOFF

SN04
2"
2

SN03
2"
NOTE 4

3
BS01

NOTE 14

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


PMC :

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

FATTY MATTER
TRANSFER PUMPS
P-3501 A&B
4 "- 35 - 1403 - B001 - IT

PIPING & INSTRUMENTATION DIAGRAM


FATTY MATTER TANK (T3)

FATTY MATTER
TA1179-D-5212-1030

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1014

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1015
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. PV VALVE.

COLD FILTRATION
PLANT (P4)

3. DIPPING HATCH + DATUM PLATE.


4. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF
NEEDED.

6 "- 31 - 0601 -A001 -NI

RECYCLE FROM
TRUCK LOADING
PUMPS P-3101 A/B/C
BIODIESEL
TA1179-D-5212-1028

5. J-TUBE + IMPINGEMENT PLATE FOR TOP INLET.


6. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN
CONTROL ROOM.
3 "- 31 - 2814 -A001 -NI

7. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION


WILL INITIATE PUMP SHUTDOWN; STOP OF DESMET PUMPS 390P5 AND
1000P6 A/B.
8. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.
9. IN CASE OF BLANKETED TANK, EMERGENCY HATCH SHALL BE
PROVIDED TO AVOID TANK DAMAGE DUE TO OVERPRESSURE.
10. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.
PVV
31011

NOTE 2, 11

REF. DWG M-00.014, 054


FOR DETAILS ON TANK
NITROGEN
BLANKETING SYSTEM

ATM

ATM

NOTE 9
RN03, 04
8"
RN31

NOTE 3

RM01
20

RN32

HH

LZA
31011

LZSHH
31011

LI

LIA

31011

31011

LT
31011

LI
31011

NOTE 6
L

12. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.
13. TANK FIRE FIGHTING PROVISIONS INCL. SPRINKLER COOLING AND
FOAM SUPPLY SHALL BE ACCORDING TO NFPA REQUIREMENTS.

NOTE 10

NOTE 1

14. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

RN05
8"
RN08
3

RN33*

MH

11. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API


2000.

NOTE 7

RN06
6

RN07
6

RN20
6"

NOTE 5

T-3101
BIODIESEL

SN10
3

MANHOLE
WITH DAVIT

SN04
4"
2

BIODIESEL EXPORT
PUMPS P-3102 A&B

SN03
8"
2"
NOTE 4

3
BS01

NOTE 14

12 "- 31 - 1512 - A001 - NI

10 "- 31 - 1511 - A001 - NI

T-3102
BIODIESEL

6 "- 31 - 1502 -A001 -NI

12 "- 31 - 1505 -A001 -NI


SM01 - 24
SM01 - 24
SM02 - 24"

WATER
DRAWOFF

NOTE 8

SN02
12"
2

MH

6 "- 31 - 1501 -A001 -NI

31011

12 "- 31 - 1510 - A001 -NI

LSLL

10 "- 31 - 1509 - A001 -NI

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

BIODIESEL
TA1179-D-5212-1006

BIODIESEL
TA1179-D-5212-1027

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

BIODIESEL TRUCK
LOADING PUMPS
P-3101 A, B & C

REV.

BIODIESEL
TA1179-D-5212-1028

CLIENT :

DESCRIPTION

CHKD APPD

DATE

REVISIONS
2

PT. SMART Tbk.


12 "- 31 - 1506 - A001 -NI
PMC :

CONSULTANT :

T-3103
BIODIESEL

6 "- 31 - 1503 -A001 -NI

ROYAL HASKONINGDHV

12 "- 31 - 1507 - A001 -NI


PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

T-3104
BIODIESEL

6 "- 31 - 1504 -A001 -NI

PIPING & INSTRUMENTATION DIAGRAM


BIODIESEL TANKS (T3)

12 "- 31 - 1508 - A001 -NI


PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1015

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1016
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. VENT + BIRDSCREEN.
3. DIPPING HATCH + DATUM PLATE.

BIODIESEL PLANT (P3)


2 "- 24 - 0511 - B001 -NI

OFF-SPEC GLYCERIN
FROM T-3301 & T-3302
OFF-SPEC GLYCERIN
TA1179-D-5212-1031

3 "- 33 - 3108 - B001 -NI

NITROGEN
-

4. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF


NEEDED.

COMPRESSED AIR
-

5. J-TUBE + IMPINGEMENT PLATE FOR TOP INLET.

DOMESTIC WATER
-

6. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN


CONTROL ROOM.

LOW PRESSURE STEAM


-

OFF-SPEC GLYCERIN
FROM T-3311 - T-3314
OFF-SPEC GLYCERIN
TA1179-D-5212-1032

7. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION


WILL INITIATE PUMP SHUTDOWN.
8. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.

44""- 33 - 3211 - B001 -NI

9. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.


10. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API
2000.

JETTY

CRUDE GLYCERIN
TA1179-D-5212-1001

11. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

6"
6 "- 24 - 0104 - B001 -NI
NOTE 7

RECYCLE FROM
EXPORT PUMPS
P-2403 A&B

LZA

HH

NOTE 2, 10

24011

CRUDE GLYCERIN
TA1179-D-5212-1029

LIA

24011

24011

LZSHH
24011

LI
24011

LT
24011

RN01, 02
8"

NOTE 6

12. NUMBER OF INLET AND OUTLET NOZZLES FOR HEATING COIL


DEPENDS ON THE REQUIRED HEATING CAPACITY PER TANK. REFER
TO UTILITY DRAWING M-00.070 (TANK DETAIL) FOR DETAILS OF TANK
HEATING ARRANGEMENT.

NOTE 9

13. TANK FIRE FIGHTING PROVISIONS INCL. SPRINKLER COOLING AND


FOAM SUPPLY SHALL BE ACCORDING TO NFPA REQUIREMENTS.

NOTE 1

14. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

NOTE 4
4"
4 "- 24 - 3802 - B001 -NI

RN08
3

MH
RM01
20

ATM

TRUCK UNLOADING
PUMP P-2401 (B1)
CRUDE GLYCERIN
TA1179-D-5212-1038

LI

X "- 24 - 2915 - B001 -NI

15. SIDE SKIMMING NOZZLES FOR REMOVAL OF FATTY MATTER.


RN07
6

RN06
6

RN20
8"

16. UTILITY STATION IN TANK BUNDED AREA SHALL PROVIDE


NITROGEN, COMPRSSED AIR, DOMESTIC WATER AND LOW PRESSURE
STEAM.

SN05
6"

3 "- 24 - 1607 - B001 -NI

SN06
6"

3 "- 24 - 1608 - B001 -NI

SN07
6"

3 "- 24 - 1609 - B001 -NI

17. CONNECTION FOR PIPE PURGING.

NOTE 5

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

U.S.

NOTE 15

NOTE16

T-2401
4

CRUDE GLYCERIN

LG

SN11
2"

TT
24011

6"
6 "- 24 - 1601 - B001 -NI

REF. DWG M-00.XXX


FOR DETAILS ON TANK HEATING SYSTEM

LG

LG

HH
H
L
I

SN10
3

MANHOLE
WITH DAVIT

SN30, 31

LSLL
24011

NOTE 8

NOTE17

NOTE 12
SN02
6"
2

MH

SN32, 33

6"
6 "- 24 - 1603 - B001 - NI
SM01 - 24
SM01 - 24
SM02 - 24"

WATER
DRAWOFF

3 "- 24 - 1613 - B001 -NI

SN04
4"
2

NOTE 20

SN03
4"
2"
NOTE 4

3
BS01

NOTE 14

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

PMC :

2 "- 24 - 1607 - B001 -NI


N2

CONSULTANT :

CRUDE GLYCERIN
TA1179-D-5212-1029

ROYAL HASKONINGDHV

CRUDE GLYCERIN
TRANSFER PUMPS
P-2402 A&B
2"
2 "- 24 - 1605 - B001 -NI

PROJECT :

SMART MARUNDA BIODIESEL PLANT

CRUDE GLYCERIN
TA1179-D-5212-1029
TITLE :

CRUDE GLYCERIN
EXPORT PUMPS
P-2403 A&B
6"
6 "- 24 - 1606 - B001 -NI

PIPING & INSTRUMENTATION DIAGRAM


CRUDE GLYCERIN TANKS (T3)

CRUDE GLYCERIN
TA1179-D-5212-1029

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

6"
6 "- 24 - 1604 - B001 -NI

NOTE17

PI
24101

PL/PR-2402

DATE

PT. SMART Tbk.

3 "- 24 - 1612 - B001 -NI

CRUDE GLYCERIN
TRANSFER PUMPS
P-2402 A&B

PIG.SIG.
24101

CHKD APPD

REVISIONS

3 "- 24 - 1611 - B001 -NI

T-2402
CRUDE GLYCERIN

6"
6 "- 24 - 1602 - B001 -NI

DESCRIPTION

CLIENT :

3 "- 24 - 1610 - B001 -NI

3 "- 24 - 1614 - B001 -NI

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

CRUDE GLYCERIN
TA1179-D-5212-1005

TA1179-D-5212-1016

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1017
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. PV VALVE.

GLYCERIN REFINING
PLANT (P2)

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

YELLOW GLYCERIN
TA1179-D-5212-1004

3. DIPPING HATCH + DATUM PLATE.


4. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF
NEEDED.

2 "- 25 - 0406 - B001 -NI

YELLOW GLYCERIN
TRANSFER PUMP
P-2501
YELLOW GLYCERIN
TA1179-D-5212-1030

5. PRODUCT INLET VIA TANK TOP, WITH J-TUBE AND IMPINGEMENT


PLATE TO AVOID SPLASHING.
6. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN
CONTROL ROOM.

2 "- 25 - 3013 - B001 -NI

7. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION


WILL INITIATE PUMP SHUTDOWN.
8. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.
9. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.
10. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API
2000.
PVV
25011

REF. DWG M-00.014, 054


FOR DETAILS ON TANK
NITROGEN
BLANKETING SYSTEM

ATM

ATM

NOTE 14
RN03, 04
8"
RN31

NOTE 3

RM01
20

RN32

HH

LZA
25011

LZSHH
25011

LI

LIA

25011

25011

LI
25011

LT
25011

H
L

12. NUMBER OF INLET AND OUTLET NOZZLES FOR HEATING COIL


DEPENDS ON THE REQUIRED HEATING CAPACITY PER TANK. REFER
TO UTILITY DRAWING M-00.070 (TANK DETAIL) FOR DETAILS OF TANK
HEATING ARRANGEMENT.
NOTE 9

13. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

RN05
8"

14. IN CASE OF BLANKETED TANK, EMERGENCY HATCH SHALL BE


PROVIDED TO AVOID TANK DAMAGE DUE TO OVERPRESSURE.

RN08
3

RN06
6

NOTE 6

NOTE 1

RN33*

MH

11. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

NOTE 7
NOTE 2, 10

RN07
6

RN20
8"

NOTE 5

T-2501
YELLOW GLYCERIN
SN11
2"

TT
25011

2 "- 25 - 1701 - B001 -NI

L
I

REF. DWG M-00.XXX


FOR DETAILS ON TANK HEATING SYSTEM

HH
H

SN10
3

MANHOLE
WITH DAVIT

SN30, 31

LSLL
25011

NOTE 8

NOTE 12
SN02
2"

MH

SN32, 33

2 "- 25 - 1702 - B001 -NI


SM01 - 24

WATER
DRAWOFF

SN04
2"

SN03
2"
NOTE 4

3
BS01

NOTE 13

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


PMC :

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

YELLOW GLYCERIN
TRANSFER PUMP
P-2501
2 "- 25 - 1703 - B001 -NI

PIPING & INSTRUMENTATION DIAGRAM


YELLOW GLYCERIN TANK (T3)

YELLOW GLYCERIN
TA1179-D-5212-1030

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1017

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1018
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. PV VALVE.

GLYCERIN REFINING
PLANT (P2)

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

REFINED GLYCERIN
TA1179-D-5212-1004

3. DIPPING HATCH + STILLING WELL AND DATUM PLATE.


4. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF
NEEDED.

2 "- 33 - 0407 - B001 -NI

REFINED GLYCERIN
DAY TANK TRANSFER
PUMPS P-3301 A&B
REFINED GLYCERIN
TA1179-D-5212-1031

5. J-TUBE + IMPINGEMENT PLATE FOR TOP INLET.


6. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN
CONTROL ROOM.
2 "- 33 - 3116 - B001 -NI

7. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION


WILL INITIATE PUMP SHUTDOWN.
8. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.
9. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.
10. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API
2000.
PVV
33011

REF. DWG M-00.014, 054


FOR DETAILS ON TANK
NITROGEN
BLANKETING SYSTEM

ATM

ATM

NOTE 15
RN03, 04
8"
RN31

NOTE 3

RM01
20

RN32

HH

LZA
33011

LZSHH
33011

LI

LIA

33011

33011

LI
33011

LT
33011

NOTE 6

12. NUMBER OF INLET AND OUTLET NOZZLES FOR HEATING COIL


DEPENDS ON THE REQUIRED HEATING CAPACITY PER TANK. REFER
TO UTILITY DRAWING M-00.070 (TANK DETAIL) FOR DETAILS OF TANK
HEATING ARRANGEMENT.

NOTE 9

13. TANK FIRE FIGHTING PROVISIONS INCL. SPRINKLER COOLING AND


FOAM SUPPLY SHALL BE ACCORDING TO NFPA REQUIREMENTS.

NOTE 1
RN05
8"

14. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

RN08
3

RN33*

MH

11. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

NOTE 7
NOTE 2, 10

RN06
6

15. IN CASE OF BLANKETED TANK, EMERGENCY HATCH SHALL BE


PROVIDED TO AVOID TANK DAMAGE DUE TO OVERPRESSURE.

RN07
6

RN20
2"

NOTE 5

T-3301
REFINED GLYCERIN DAY TANK
SN11
2"

TT
33011

2 "- 33 - 1801 - B001 -NI

REF. DWG M-00.XXX


FOR DETAILS ON TANK HEATING SYSTEM

SN10
3

MANHOLE
WITH DAVIT

SN30, 31

LSLL
33011

NOTE 8

NOTE 12
SN02
3"

MH

SN32, 33

3 "- 33 - 1803 - B001 -NI


SM01 - 24

WATER
DRAWOFF

SN04
2"

SN03
2"
NOTE 4

3
BS01

NOTE 14

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

T-3302
REFINED GLYCERIN
DAY TANK

2 "- 33 - 1802 - B001 -NI

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


3 "- 33 - 1804 - B001 -NI
PMC :

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

REFINED GLYCERIN
TRANSFER PUMPS
P-3301 A&B
3 "- 33 - 1805 - B001 -NI

PIPING & INSTRUMENTATION DIAGRAM


REFINED GLYCERIN DAY TANKS (T3)

REFINED GLYCERIN
TA1179-D-5212-1031

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1018

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1019
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. PV VALVE.

DAYTANK TRANSFER
PUMPS P-3301 A&B

3. IN CASE OF BLANKETED TANK, EMERGENCY HATCH SHALL BE


PROVIDED TO AVOID TANK DAMAGE DUE TO OVERPRESSURE.
6 "- 33 - 3107 - B001 -NI

REFINED GLYCERIN
TA1179-D-5212-1032

5. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF


NEEDED.
6. J-TUBE + IMPINGEMENT PLATE FOR TOP INLET.
6 "- 33 - 3207 - B001 -NI

7. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN


CONTROL ROOM.

REFINED GLYCERIN
DRUMMING TRANSER
PUMPS P-3303 A&B
REFINED GLYCERIN
TA1179-D-5212-1031

4. DIPPING HATCH +DATUM PLATE.

RECYCLE FROM
TRUCK LOADING
PUMPS P-3302 A&B

8. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION


WILL INITIATE PUMP SHUTDOWN.
2 "- 33 - 3117 - B001 -NI

9. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP


SHUTDOWN.
10. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.
PVV
33111

REF. DWG M-00.014, 054


FOR DETAILS ON TANK
NITROGEN
BLANKETING SYSTEM

ATM

ATM

NOTE 3
RN03, 04
8"
RN31

NOTE 4

RM01
20

RN32

HH

LZA
33111

LZSHH
33111

LI

LIA

33111

33111

LT
33111

LI
33111

12. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

NOTE 7
L

13. NUMBER OF INLET AND OUTLET NOZZLES FOR HEATING COIL


DEPENDS ON THE REQUIRED HEATING CAPACITY PER TANK. REFER
TO UTILITY DRAWING M-00.070 (TANK DETAIL) FOR DETAILS OF TANK
HEATING ARRANGEMENT.

NOTE 10

NOTE 1
RN05
8"

14. TANK FIRE FIGHTING PROVISIONS INCL. SPRINKLER COOLING AND


FOAM SUPPLY SHALL BE ACCORDING TO NFPA REQUIREMENTS.

RN08
3

RN33*

MH

11. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API


2000.

NOTE 8
NOTE 2, 11

RN06
6

15. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

RN07
6

RN20
6"

NOTE 6

T-3311
REFINED GLYCERIN
SN11
2"

TT
33111

6 "- 33 - 1901 - B001 -NI

REF. DWG M-00.XXX


FOR DETAILS ON TANK HEATING SYSTEM

SN10
3

MANHOLE
WITH DAVIT

SN30, 31

LSLL
33111

NOTE 9

NOTE 13
SN02
4"

MH

4 "- 33 - 1905 - B001 -NI


SM01 - 24
SM01 - 24
SM02 - 24"

WATER
DRAWOFF

SN04
4"

DRUMMING TRANSFER
PUMPS P-3303 A&B

SN03
2"
NOTE 5

3
BS01

NOTE 15

T-3312
REFINED
GLYCERIN

2
6 "- 33 - 1902 - B001 -NI

6 "- 33 - 1912 - B001 - NI

REFINED GLYCERIN
TA1179-D-5212-1031
3

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

TRUCK LOADING
PUMPS P-3302 A&B

REV.

REFINED GLYCERIN
TA1179-D-5212-1032

CLIENT :

DESCRIPTION

CHKD APPD

DATE

REVISIONS
2

PT. SMART Tbk.


4 "- 33 - 1906 - B001 -NI
PMC :

T-3313
REFINED
GLYCERIN

6 "- 33 - 1903 - B001 -NI

4 "- 33 - 1911 - B001 - NI

4 "- 33 - 1910 - B001 -NI

SN32, 33

4 "- 33 - 1909 - B001 -NI

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

REFINED GLYCERIN
TA1179-D-5212-1031

CONSULTANT :

ROYAL HASKONINGDHV

4 "- 33 - 1907 - B001 -NI


PROJECT :

SMART MARUNDA BIODIESEL PLANT

T-3314
REFINED
GLYCERIN

6 "- 33 - 1904 - B001 -NI

TITLE :

PIPING & INSTRUMENTATION DIAGRAM


REFINED GLYCERIN TANKS (T3)

4 "- 33 - 1908 - B001 -NI


PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1019

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1020
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. PV VALVE.

SLOP BIODIESEL
TRANSFER PUMP
P-2201

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

SLOP BIODIESEL
TA1179-D-5212-1033

3. IN CASE OF BLANKETED TANK, EMERGENCY HATCH SHALL BE


PROVIDED TO AVOID TANK DAMAGE DUE TO OVERPRESSURE.
2 "- 22 - 3312 -A001 - IT

SLOP BIODIESEL
TA1179-D-5212-1028

5. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF


NEEDED.
6. J-TUBE + IMPINGEMENT PLATE FOR TOP INLET.
2"
2 "- 31 - 2812 -A001 -NI

7. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN


CONTROL ROOM.

INTERMEDIATE
BIODIESEL TRANSFER
PUMP P-2601 A/B
SLOP BIODIESEL
TA1179-D-5212-1026

4. DIPPING HATCH + DATUM PLATE.

BIODIESEL SLOP FROM


TRUCK LOADING PUMP
P-3101 A/B/C

8. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION


WILL INITIATE PUMP SHUTDOWN.
6"
6 "- 26 - 2612 -A001 -NI

9. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP


SHUTDOWN.
BIODIESEL PLANT (P3)

SLOP BIODIESEL
TA1179-D-5212-1005

10. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.


PVV
22011

4 "- 22 - 0509 -A001 - IT

REF. DWG M-00.014, 054


FOR DETAILS ON TANK
NITROGEN
BLANKETING SYSTEM

ATM

ATM

NOTE 3
RN03, 04
8"
RN31

NOTE 4

RM01
20

RN32

HH

LZA
22011

LZSHH
22011

LI

LIA

22011

22011

LT
22011

LI
22011

12. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

NOTE 7
L

13. NUMBER OF INLET AND OUTLET NOZZLES FOR HEATING COIL


DEPENDS ON THE REQUIRED HEATING CAPACITY PER TANK. REFER
TO UTILITY DRAWING M-00.XXX (TANK DETAIL) FOR DETAILS OF TANK
HEATING ARRANGEMENT.

NOTE 10

NOTE 1
RN05
8"

14. TANK FIRE FIGHTING PROVISIONS INCL. SPRINKLER COOLING AND


FOAM SUPPLY SHALL BE ACCORDING TO NFPA REQUIREMENTS.

RN08
3

RN33*

MH

11. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API


2000.

NOTE 8
NOTE 2, 11

RN06
6

15. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

RN07
6

RN20
6"

NOTE 6

T-2201
SLOP BIODIESEL
SN11
2"

TT
22011

6 "- 22 - 2001 -A001 - IT

REF. DWG M-00.XXX


FOR DETAILS ON TANK HEATING SYSTEM

SN10
3

MANHOLE
WITH DAVIT

SN30, 31

LSLL
22011

NOTE 9

NOTE 13
SN02
3"

MH

SN32, 33

3 "- 22 - 2002 - A001 - IT


SM01 - 24

WATER
DRAWOFF

SN04
2"

SN03
2"
NOTE 5

3
BS01

NOTE 15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


PMC :

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

SLOP BIODIESEL
TRANSFER PUMP
P-2201
3 "- 22 - 2003 - A001 - IT

PIPING & INSTRUMENTATION DIAGRAM


SLOP BIODIESEL TANK (T3)

SLOP BIODIESEL
TA1179-D-5212-1033

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1020

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1021
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. PV VALVE.

SLOP GLYCERIN
TRANSFER PUMP
P-2301

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

SLOP GLYCERIN
TA1179-D-5212-1033

3. DIPPING HATCH + DATUM PLATE.


4. TANK FOAMBOX NOZZLE FOR FIRE FIGHTING; FOR DETAILS REFER
TO FIREFIGHTING DESIGN DOCUMENTS.

2 "- 23 - 3311 - B001 - IT

YELLOW GLYCERIN
TRANSFER PUMP
P-2501
YELLOW GLYCERIN
TA1179-D-5212-1030

5. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF


NEEDED.
6. J-TUBE + IMPINGEMENT PLATE FOR TOP INLET.
2 "- 25 - 3012 - B001 -NI

7. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN


CONTROL ROOM.

CRUDE GLYCERIN
TRANSFER PUMPS
P-2403 A/B
SLOP GLYCERIN
TA1179-D-5212-1029

8. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION


WILL INITIATE PUMP SHUTDOWN.
2 "- 24 - 2908 - B001 -NI

9. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP


SHUTDOWN.

FATTY MATTER
EXPORT PUMPS
P-3501 A/B

SLOP GLYCERIN
TA1179-D-5212-1030

10. IN CASE OF BLANKETED TANK, EMERGENCY HATCH SHALL BE


PROVIDED TO AVOID TANK DAMAGE DUE TO OVERPRESSURE.
PVV
23011

4"
4 "- 35 - 3008 - B001 - IT

BIODIESEL PLANT (P3)


SLOP GLYCERIN
TA1179-D-5212-1005

REF. DWG M-00.014, 054


FOR DETAILS ON TANK
NITROGEN
BLANKETING SYSTEM

2"
2 "- 23 - 0510 - B001 - IT

ATM

ATM

NOTE 10, 20
RN03, 04
8"
RN31

NOTE 3

RM01
20

RN32

23011

LZSHH
23011

LI

LIA

23011

23011

LT
23011

LI
23011

12. AMOUNT AND TYPE OF FOAM BOXES REQUIRED MAY DIFFER WITH
SIZE AND TYPE OF TANK. REQUIREMENTS OF NFPA 11 SHALL BE MET.

NOTE 7
L

13. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO


GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.
NOTE 11

14. NUMBER OF INLET AND OUTLET NOZZLES FOR HEATING COIL


DEPENDS ON THE REQUIRED HEATING CAPACITY PER TANK. REFER
TO UTILITY DRAWING M-00.XXX (TANK DETAIL) FOR DETAILS OF TANK
HEATING ARRANGEMENT.

NOTE 1
RN05
8"
RN08
3

RN33*

MH

HH

LZA

RN06
6

11. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.

NOTE 8
NOTE 2, 18

RN07
6

15. PERSONNEL PROTECTION INSULATION FOR TANK SHELL AND


ROOF.

PP
NOTE 15

16. TANK FIRE FIGHTING PROVISIONS INCL. SPRINKLER COOLING AND


FOAM SUPPLY SHALL BE ACCORDING TO NFPA REQUIREMENTS.

RN20
4"

REF. DWG M-00.059, 019


FOR DETAILS OF
FIRE FIGHTING SYSTEM

5
SN20

17. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP 5


LAYER PROVIDED BY OTHERS.

FOAM BOX NOZZLE

18. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API


2000.

NOTE 6
NOTE 4, 12

PURGING.
19. CONNECTION FOR PIPE PURGING
20. ALARM TO CONTROL ROOM IN CASE HATCH IS LIFTED.

PP
NOTE 15

T-2301
SLOP GLYCERIN
SN11
2"

TT
23011

4 "- 23 - 2101 - B001 - IT

L
I

REF. DWG M-00.XXX


FOR DETAILS ON TANK HEATING SYSTEM

HH
H

SN10
3

MANHOLE
WITH DAVIT

SN30, 31

LSLL
23011

NOTE 9

NOTE19

NOTE 14
SN02
3"

MH

SN32, 33

3 "- 23 - 2102 - B001 - IT


SM01 - 24

WATER
DRAWOFF

SN04
2"

SN03
2"
NOTE 5

3
BS01

NOTE 17

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


PMC :

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

SLOP GLYCERIN
TRANSFER PUMP
P-2301
3 "- 23 - 2103 - B001 - IT

PIPING & INSTRUMENTATION DIAGRAM


SLOP GLYCERIN TANK (T3)

SLOP GLYCERIN
TA1179-D-5212-1033

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1021

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1022
A

NOT TO SCALE

NOTES :
1. RADAR TYPE LEVEL TRANSMITTER.
2. VENT + BIRDSCREEN.

GLYCERIN REFINING
PLANT (P2)

3. DIPPING HATCH + DATUM PLATE.

2 "- 34 - 0405 - C001 - IT

PITCH GLYCERIN
TRUCK LOADING
PUMPS P-3401 A&B
PITCH GLYCERIN
TA1179-D-5212-1032

2 "- 34 - 3219 - C001 - IT

NITROGEN
-

4. LOW SUCTION (STRIPPING) CONNECTION TO EMPTY TANK IF


NEEDED.

COMPRESSED AIR
-

5. J-TUBE + IMPINGEMENT PLATE FOR TOP INLET.

DOMESTIC WATER
-

6. TANK LEVEL LOW AND HIGH GENERATE AUDIOVISUAL ALARM IN


CONTROL ROOM.

LOW PRESSURE STEAM


-

7. TANK HIGH HIGH LEVEL DURING FILLING AND/OR RECIRCULATION


WILL INITIATE PUMP SHUTDOWN.
8. TANK LOW LOW LEVEL INITIATES TRANSFER / EXPORT PUMP
SHUTDOWN.
9. LEVEL INDICATOR SHALL BE VISIBLE FROM GRADE.
10. TANK VENT CAPACITY SHALL BE DESIGNED ACCORDING TO API
2000.
11. BOTTOM AND ROOF CONFIGURATION VARY PER TANK. REFER TO
GENERAL ARRANGEMENT DRAWINGS FOR DETAILS.

6
NOTE 7
LZA

HH

NOTE 2, 10

34011

LIA

34011

34011

NOTE 6

12. NUMBER OF INLET AND OUTLET NOZZLES FOR HEATING COIL


DEPENDS ON THE REQUIRED HEATING CAPACITY PER TANK. REFER
TO UTILITY DRAWING M-00.070 (TANK DETAIL) FOR DETAILS OF TANK
HEATING ARRANGEMENT.

NOTE 9

13. TANK FIRE FIGHTING PROVISIONS INCL. SPRINKLER COOLING AND


FOAM SUPPLY SHALL BE ACCORDING TO NFPA REQUIREMENTS.

ATM
LZSHH
34011

LI
34011

LT
34011

RN01, 02
3"

NOTE 1

14. TANK FOUNDATION REINFORCED CONCRETE SLAB + BITUMEN TOP


LAYER PROVIDED BY OTHERS.

NOTE 3
RN08
3

MH
RM01
20

LI

RN07
6"

RN06
6

15. HEAT CONSERVATION INSULATION TO TANK SHELL,AND


PERSONNEL PROTECTION INSULATION FOR TANK ROOF.

PP
NOTE 15

16. LOW TEMPERATURE ALARM SET AT 60C TO AVOID


SOLIDIFICATION OF PRODUCT.

RN20
2"

INS

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

U.S.

NOTE 15

1/2"

NOTE 5

1/2"

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

PITCH GLYCERIN
TA1179-D-5212-1004

NOTE6

T-3401
PITCH GLYCERIN
SN11
2"

TT
34011

2 "- 34 - 2201 - C001 - IT

L
I

REF. DWG M-00.XXX


FOR DETAILS ON TANK HEATING SYSTEM

HH
H

SN10
3

MANHOLE
WITH DAVIT

SN30, 31

LSLL
34011

NOTE 8

NOTE 12
SN02
2"
2

MH

SN32, 33

2 "- 34 - 2203 -C001 - IT


SM01 - 24

WATER
DRAWOFF

SN04
2"
2

SN03
2"
NOTE 4

3
BS01

NOTE 14

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

PT. SMART Tbk.

T-3402
PITCH GLYCERIN

2 "- 34 - 2202 - C001 - IT

DATE

REVISIONS

CLIENT :

CHKD APPD

2 "- 34 - 2204 - C001 - IT


PMC :

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

PITCH GLYCERIN
TRUCK LOADING
PUMPS P-3401 A&B
4 "- 34 - 2205 - C001 - IT

PIPING & INSTRUMENTATION DIAGRAM


PITCH GLYCERIN TANKS (T3)

PITCH GLYCERIN
TA1179-D-5212-1032

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1022

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1023
A

NOT TO SCALE

NOTES :
1. PUMP SUPPLIED BY LIPICO (PUMP + SUCTION AND DISCHARGE
FLANGES).
2. SAMPLE POINT ON PUMP VENT CONNECTION.
3. CONNECTION FOR PIPE PURGING.
7

4. PRESSURE SAFETY VALVE PROVIDED BY LIPICO.

FAULT
ALARM

XA
62051

XS
LOCAL/
REMOTE 62051

XL
62051

RUNNING
LIGHT
I

HS
62051

PDI
62051

PI
62051

NOTE 2

1/2

START/
STOP

NOTE 4
SET PRESSURE
8 BARG

HYDROCHLORIC ACID
TANKS T-6201, T-6202,
T-6203

SV
4211

2 "- 62 - 2302 - E001 - NI

2 "- 62 - 2303 - E001 - NI


2" X 1"

HYDROCHLORIC ACID
TA1179-D-5212-1009

2 "- 62 - 2311 - E001 -NI

1" X 2"

HYDROCHLORIC ACID
TA1179-D-5212-1009

2 "- 62 - 2310 - E001 - NI

PU4211 A

1/2

HYDROCHLORIC ACID
TANKS T-6201, T-6202,
T-6203

HYDROCHLORIC ACID
TRANSFER PUMP
NOTE 1

NOTE3

BIODIESEL PLANT (P3)

2 "- 62 - 0907 - E001 - NI

2 "- 62 - 2307 - E001 -NI

HYDROCHLORIC ACID
TA1179-D-5212-1005

5
XA
62061

XS
LOCAL/
REMOTE 62061

XL
62061

RUNNING
LIGHT

2 "- 62 - 2306 - E001 - NI

FAULT
ALARM

2 "- 62 - 2301 - E001 - NI

I
HS
62061

PDI
62061

PI
62061

NOTE 2

1/2

START/
STOP

M
2 "- 62 - 2304 - E001 - NI

2 "- 62 - 2305 - E001 - NI

1/2

PU4211 B
HYDROCHLORIC ACID
TRANSFER PUMP
NOTE 1

3
SET PRESSURE
8 BARG
PSV
64031

PHOSPHORIC ACID
TANK T-6401
1" X 2"

2" X 1"

2 "- 64 - 2313 - C001 -NI

XA
64031

XS
LOCAL/
REMOTE 64031

XL
64031

RUNNING
LIGHT
I

HS
64031

PDI
64031

PI
64031

NOTE 2

PHOSPHORIC ACID
TANK T-6401

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

2 "- 64 - 1103 - C001 - NI

DESCRIPTION

PHOSPHORIC ACID
TA1179-D-5212-1005

2 "- 64 - 2308 - C001 - NI

CHKD APPD

DATE

REVISIONS

CLIENT :

BIODIESEL PLANT (P3)

PHOSPHORIC ACID
TA1179-D-5212-1011

REV.

1/2

START/
STOP

PHOSPHORIC ACID
TA1179-D-5212-1011

2 "- 64 - 2312 - C001 -NI

FAULT
ALARM

PT. SMART Tbk.

P-6402

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

PMC :

PHOSPHORIC ACID
TRANSFER PUMP

CONSULTANT :

ROYAL HASKONINGDHV

GLYCERIN REFINING
PLANT (P2)
2 "- 64 - 2309 - C001 -NI

PHOSPHORIC ACID
TA1179-D-5212-1004

PROJECT :

SMART MARUNDA BIODIESEL PLANT

TITLE :

PIPING & INSTRUMENTATION DIAGRAM


CHEMICAL TRANSFER PUMPS 1 (B1)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1023

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1024
A

NOT TO SCALE

NOTES :
1. PUMP SUPPLIED BY LIPICO (PUMP + SUCTION AND DISCHARGE
FLANGES).
2. SAMPLE POINT ON PUMP VENT CONNECTION.

3. UTILITY STATION AT PUMP ROOM SHALL PROVIDE NITROGEN,


COMPRESSED AIR, DOMESTIC WATER AND LOW PRESSURE STEAM.

NITROGEN
-

DOMESTIC WATER
-

FAULT
ALARM

LOW PRESSURE STEAM


-

5. PUMPS P-1201 A/B INTERLOCKED WITH MOV1201-1 ON METHANOL


TANKS; IF MOV CLOSED, PUMPS CANNOT START; IF PUMP TRIPS, MOV
WILL CLODE.

XA
63031

XS
LOCAL/
REMOTE 63031

XL
63031

6. CONNECTION FOR PIPE PURGING.

RUNNING
LIGHT
I

HS
63031

PDI
63031

PI
63031

NOTE 2

1/2

START/
STOP

M
U.S.

2" X "

1/2"

PU4222 A

1/2

SODIUM HYDROXIDE
TANK T-6301

SV
4222

2 "- 63 - 2403 - A001 - NI

SODIUM HYDROXIDE
TRANSFER PUMP
NOTE 1

" X 2"

2 "- 63 - 2409 -A001 -NI

NOTE3

SODIUM HYDROXIDE
TANK T-6301
SODIUM HYDROXIDE
TA1179-D-5212-1010

SODIUM HYDROXIDE
TA1179-D-5212-1010

2 "- 63 - 2408 -A001 -NI

1/2"

1/2"
1/2"

1/2"
1/2"

1/2"

NOTE 4
SET PRESSURE
8 BARG

2 "- 63 - 2402 -A001 - NI

1/2"

BIODIESEL PLANT (P3)


2 "- 63 - 1003 - A001 - NI

SODIUM HYDROXIDE
TA1179-D-5212-1005

2"
2 "- 63 - 2407 - A001 -NI

5
XA
63041

XS
LOCAL/
REMOTE 63041

XL
63041

RUNNING
LIGHT

2"
2 "- 63 - 2406 -A001 -NI

X "- 63 - 2401 -A001 -NI

FAULT
ALARM

I
HS
63041

PDI
63041

PI
63041

NOTE 2

1/2

START/
STOP

2 "- 63 - 2404 -A001 - NI

2 "- 63 - 2405 - A001 - NI

1/2

PU4222 B
SODIUM HYDROXIDE
TRANSFER PUMP
NOTE 1

FAULT
ALARM

XA
12031

XS
LOCAL/
REMOTE 12031

XL
12031

RUNNING
LIGHT
I

HS
12031

PDI
12031

PI
12031

NOTE 2

1/2

START/
STOP

M
3

2 "- 12 - 2502 -A001 - NI

2 "- 12 - 2503 - A001 - NI

1/2

P-1201 A
METHANOL
TRANSFER PUMP
NOTE 1

2 "- 12 - 2525 - A001 -NI

METHANOL TANKS
T-1201, T-1202

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

METHANOL
TA1179-D-5212-1007

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CLIENT :

FAULT
ALARM

2 "- 12 - 2506 -A001 - NI

2 "- 12 - 0705 - A001 - NI

XA
12041

XS
LOCAL/
REMOTE 12041

XL
12041

RUNNING
LIGHT

PMC :

BIODIESEL PLANT (P3)

HS
12041

PDI
12041

DATE

PT. SMART Tbk.

I
START/
STOP

CHKD APPD

REVISIONS

PI
12041

METHANOL
TA1179-D-5212-1005

2 "- 12 - 2507 - A001 -NI

NOTE 2

CONSULTANT :

1/2

METHANOL
TA1179-D-5212-1007

METHANOL TANKS
T-1201, T-1202

NOTE6

2 "- 12 - 2501 - A001 -NI

ROYAL HASKONINGDHV

M
PROJECT :
2 "- 12 - 2504 -A001 - NI

2 "- 12 - 2505 - A001 - NI

SMART MARUNDA BIODIESEL PLANT

P-1201 B

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

4. PRESSURE SAFETY VALVE PROVIDED BY LIPICO.

COMPRESSED AIR
-

TITLE :

METHANOL
TRANSFER PUMP
NOTE 1

PIPING & INSTRUMENTATION DIAGRAM


CHEMICAL TRANSFER PUMPS 2 (B1)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1024

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1025
A

NOT TO SCALE

NOTES :
1. PUMP SUPPLIED BY LIPICO.
2. SAMPLE POINT ON PUMP VENT CONNECTION.
3. UTILITY STATION AT PUMP ROOM SHALL PROVIDE NITROGEN,
COMPRESSED AIR, DOMESTIC WATER AND LOW PRESSURE STEAM.

NITROGEN
-

7
4. PRESSURE SAFETY VALVES PROVIDED BY LIPICO.

DOMESTIC WATER
LOW PRESSURE STEAM
-

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

U.S.

NOTE3

61041

XS
LOCAL/
REMOTE 61041

NOTE 4
SET PRESSURE
8 BARG

XA
XL
61041

SV
3322A

RUNNING
LIGHT

1" X 2"
2 "- 61 - 2519 - A001 -NI

2" X 1"

FAULT
ALARM

HS
61041

PDI
61041

PI
61041

NOTE 2

1/2

START/
STOP

2 "- 61 - 2518 - A001 -NI

2 "- 61 - 2509 -A001 - NI

SODIUM METHYLATE
TANKS T-6101, T-6102
SODIUM METHYLATE
TA1179-D-5212-1008

2 "- 61 - 2510 - A001 - NI


2 "- 61 - 2524 -A001 -NI

1/2

PU3322 A
SODIUM
METHYLATE
TRANSFER PUMP
NOTE 1

4
SODIUM METHYLATE
TANKS T-6101, T-6102

BIODIESEL PLANT (P3)


2 "- 61 - 0805 - A001 - NI

SODIUM METHYLATE
TA1179-D-5212-1005

2 "- 61 - 2514 - A001 -NI

FAULT
ALARM

NOTE 4
SET PRESSURE
8 BARG

XA
61051

XS
LOCAL/
REMOTE 61051

XL
61051

SV
3322B

RUNNING
LIGHT

1" X 2"
2 "- 61 - 2521 - A001 - NI

2" X 1"

SODIUM METHYLATE
TA1179-D-5212-1008

HS
61051

PDI
61051

PI
61051

NOTE 2

1/2

START/
STOP

2 "- 61 - 2520 - A001 -NI

M
2 "- 61 - 2511 -A001 - NI

2 "- 61 - 2512 - A001 - NI

1/2

PU3322 B
SODIUM
METHYLATE
TRANSFER PUMP
NOTE 1

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

DATE

PT. SMART Tbk.

BIODIESEL PLANT (P3)


SODIUM METHYLATE
TA1179-D-5212-1005

2 "- 61 - 2515 - A001 -NI

CHKD APPD

REVISIONS

CLIENT :

PMC :
NOTE 4
SET PRESSURE
8 BARG

XA

XS
LOCAL/
REMOTE 61061

XL
61061

SV
3322C

RUNNING
LIGHT

1" X 2"
2 "- 61 - 2523 - A001 - NI

PI
61061

2 "- 61 - 2522 -A001 -NI

HS
61061

NOTE 2

1/2

START/
STOP
PDI
61061

CONSULTANT :

2 "- 61 - 2513 - A001 -NI

61061

2" X 1"

FAULT
ALARM

2 "- 61 - 2508 - A001 -NI

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT

1
2 "- 61 - 2516 -A001 - NI

TITLE :

2 "- 61 - 2517 - A001 - NI

PIPING & INSTRUMENTATION DIAGRAM


CLASSIFIED PRODUCT PUMPS (B2)

PU3322 C

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

COMPRESSED AIR
-

SODIUM
METHYLATE
TRANSFER PUMP
NOTE 1

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1025

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1026
A

NOT TO SCALE

1. PUMP PU3301 A AND PU6011 A SUPPLIED BY LIPICO, PU3301 B AND


PU6011 B PROVIDED BY SMART.

COMPRESSED AIR
-

2. SAMPLE POINT ON PUMP VENT CONNECTION.

DOMESTIC WATER
-

3. UTILITY STATION AT PUMP ROOM SHALL PROVIDE NITROGEN,


COMPRESSED AIR, DOMESTIC WATER AND LOW PRESSURE STEAM.

4 "- 21 - 1205 -A001 - IT

RECIRCULATION TO
RBDPO TANKS T-2101,
T-2102
4 "- 21 - 2605 - A001 - IT

1/2"

1/2"

1/2"

1/2"

1/2"

FAULT
ALARM

XA
21031

XS
LOCAL/
REMOTE 21031

4 "- 21 - 1206 -A001 - IT

RBDPO / RBDST
TA1179-D-5212-1012

BIODIESEL PLANT (P3)


XL
21031

RUNNING
LIGHT

4 "- 21 - 2606 - A001 - IT

RBDPO / RBDST
TA1179-D-5212-1005

NOTE3
START/
STOP

HS
21031

PDI
21031

PI
21031

NOTE 2

1/2

RBDPO
TA1179-D-5212-1012

1/2"

RBDPO TANKS T-2101,


T-2102

1/2"

U.S.

1/2"

4"
4 "- 21 - 2602 - A001 - IT

6 "- 21 - 2601 -A001 - IT

1/2

PU3301 A
RBDPO / RBDST
TRANSFER PUMP
NOTE 1

FAULT
ALARM

XA
21041

XS
LOCAL/
REMOTE 21041

XL
21041

RUNNING
LIGHT
I

HS
21041

PDI
21041

PI
21041

NOTE 2

1/2

START/
STOP

M
4

4
4"
4 "- 21 - 2604 - A001 - IT

6 "- 21 - 2603 -A001 - IT

1/2

PU3301 B
RBDPO / RBDST
TRANSFER PUMP
NOTE 1

INTERMEDIATE
BIODIESEL TANKS
T-2601, T-2602
INT. BIODIESEL
TA1179-D-5212-1013

COLD FILTRATION
PLANT (P4)
FAULT
ALARM

6 "- 26 - 1305 -A001 -NI

XA
26031

XS
LOCAL/
REMOTE 26031

XL
26031

66""- 26 - 2611 - A001 -NI


RUNNING
LIGHT

INT. BIODIESEL
TA1179-D-5212-1006

INTERMEDIATE
BIODIESEL TANKS
T-2601, T-2602
INT. BIODIESEL
TA1179-D-5212-1013

START/
STOP

HS
26031

PDI
26031

PI
26031

6 "- 26 - 1306 -A001 -NI

SLOP BIODIESEL TANK


T-2201

NOTE 2

1/2

66""- 26 - 2612 - A001 -NI

INT. BIODIESEL
TA1179-D-5212-1020

66""- 26 - 2608 - A001 - NI

6 "- 26 - 2607 -A001 - NI

1/2

PU6011 A
INT. BIODIESEL
TRANSFER PUMP
NOTE 1

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


PMC :

FAULT
ALARM

XA
26041

XS
LOCAL/
REMOTE 26041

XL
26041

CONSULTANT :
RUNNING
LIGHT

ROYAL HASKONINGDHV
I

HS
26041

PROJECT :

PDI
26041

PI
26041

SMART MARUNDA BIODIESEL PLANT

NOTE 2

1/2

START/
STOP

TITLE :

66""- 26 - 2610 - A001 - NI

6 "- 26 - 2609 -A001 - NI

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

NITROGEN
-

LOW PRESSURE STEAM


-

RBDPO TANKS T-2101,


T-2102
RBDPO
TA1179-D-5212-1012

NOTES :

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

PIPING & INSTRUMENTATION DIAGRAM

RBDPO + INT. BIODIESEL TRANSFER PUMPS (B3)

PU6011 B

PROJ. NO.

DRAWING NO.

INT. BIODIESEL
TRANSFER PUMP
NOTE 1

FILE NAME

SHEET

TA1179
P&ID

TA1179-D-5212-1026

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1027
A

NOT TO SCALE

NOTES :
1. SAMPLE POINT ON PUMP VENT CONNECTION.
2. RETURN LINE FOR PIGGING.
NITROGEN
-

3. ONE FILTER IN SERVICE, ONE STANDBY OR CLEANING.

COMPRESSED AIR
-

LOW PRESSURE STEAM


-

1/2"

1/2"

1/2"
1/2"

1/2"

1/2"

1/2"

1/2"

U.S.

NOTE2

JETTY
FAULT
ALARM

BIODIESEL EXPORT
TA1179-D-5212-1001

XA
31081

XS
LOCAL/
REMOTE 31081

XL
31081

RUNNING
LIGHT
I

START/
STOP

HS
31081

PDI
31081

NOTE 1

PI
31081

1/2

M
PDI
31111

10"
10 "- 31 - 2703 - A001 - NI

14 "- 31 - 2702 -A001 - NI

1/2

P-3102 A
BIODIESEL
EXPORT PUMP

NOTE 3
PDI
31121

8 "- 31 - 2712 - A001 - NI

BIODIESEL
PRODUCT FILTER

10"
10 "- 31 - 2710 - A001 - NI

10"
10 "- 31 - 2709 - A001 - NI

F-3102 A

BIODIESEL TANKS
T-3101 TO T-3104
10"
10 "- 31 - 2711 -A001 -NI

10"
10 "- 31 - 2708 -A001 -NI
12 "- 31 - 1512 - A001 - NI

F-3102 B

XA
31091

XS
LOCAL/
REMOTE 31091

XL
31091

10"
10 "- 31 - 2707 - A001 -NI

FAULT
ALARM

RUNNING
LIGHT
I

START/
STOP

HS
31091

PDI
31091

NOTE 1

PI
31091

BIODIESEL
PRODUCT FILTER
NOTE 3

1/2

BIODIESEL
TA1179-D-5212-1015

14 "- 31 - 2701 - A001 -NI

PI
31201

N2

3 "- 31 - 2713 -A001 -NI


NOTE 2

3 "- 31 - 2714 - A001 -NI

PL/PR-3102

P-3102 B
BIODIESEL
EXPORT PUMP

3"
3 "- 31 - 2706 -A001 -NI

PIG.SIG.
31201

10"
10 "- 31 - 2705 - A001 - NI

14 "- 31 - 2704 -A001 - NI

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

DOMESTIC WATER
-

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


PMC :

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

PIPING & INSTRUMENTATION DIAGRAM


BIODIESEL EXPORT PUMPS (B3)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1027

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1028
A

NOT TO SCALE

NOTES :
1. SAMPLE POINT ON PUMP VENT CONNECTION.
2. THROTTLE VALVE TO CONTROL FLOW RATE TO SLOP BIODIESEL
TANK.

FAULT
ALARM

XA
31051

XS
LOCAL/
REMOTE 31051

XL
31051

RUNNING
LIGHT
I

HS
31051

PDI
31051

PI
31051

NOTE 1

1/2

START/
STOP

M
12 "- 31 - 2802 -A001 - NI

10"
10 "- 31 - 2803 - A001 - NI

P-3101 A

1/2

10 "- 31 - 2810 -A001 -NI

BIODIESEL TRUCK
LOADING PUMP

BIODIESEL TANKS
T-3101 TO 3104
BIODIESEL
TA1179-D-5212-1015

PDI
31101

TRUCK LOADING BAYS


(B6)

10 "- 31 - 2809 - A001 -NI


10 "- 31 - 1511 - A001 - NI

10 "- 31 - 2811 - A001 -NI

BIODIESEL
TA1179-D-5212-1034

F-3101

5
FAULT
ALARM

31061

XS
LOCAL/
REMOTE 31061

BIODIESEL
PRODUCT FILTER

XA
XL
31061

RUNNING
LIGHT
I

HS
31061

PDI
31061

PI
31061

NOTE 1

1/2

START/
STOP

M
10"
10 "- 31 - 2805 - A001 - NI

12 "- 31 - 2804 -A001 - NI

1/2

P-3101 B
BIODIESEL TRUCK
LOADING PUMP

NOTE2
FI
31001

FCV
31001

RO
31001

SLOP BIODIESEL
TANKS T-2201
SLOP BIODIESEL
TA1179-D-5212-1020

2"
2 "- 31 - 2812 -A001 -NI

COLD FILTRATION
PLANT (P4)
SLUDGE BIODIESEL
TA1179-D-5212-1006

10 "- 31 - 2808 -A001 -NI

66""- 31 - 2813 -A001 -NI

12 "- 31 - 2801 -A001 -NI

FAULT
ALARM

RECYCLE / ITT TO
BIODIESEL TANKS
T-3101 TO T-3104
BIODIESEL
TA1179-D-5212-1015

6 "- 31 - 2814 -A001 -NI

XA
31071

XS
LOCAL/
REMOTE 31071

XL
31071

RUNNING
LIGHT
I

HS
31071

PDI
31071

PI
31071

NOTE 1

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

1/2

START/
STOP

DESCRIPTION

CLIENT :

12 "- 31 - 2806 -A001 - NI

CHKD APPD

DATE

REVISIONS

PT. SMART Tbk.

10"
10 "- 31 - 2807 - A001 - NI

P-3101 C

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

PMC :

BIODIESEL TRUCK
LOADING PUMP

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

PIPING & INSTRUMENTATION DIAGRAM


BIODIESEL TRUCK LOADING PUMPS (B3)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1028

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1029
A

NOT TO SCALE

NOTES :
1. PUMP P-2401 A (516G0) PROVIDED BY LURGI; P-2401 B PROVIDED BY
SMART.
2. SAMPLE POINT ON PUMP VENT CONNECTION.

7
CRUDE GLYCERIN
TANKS T-2401, T-2402
CRUDE GLYCERIN
TA1179-D-5212-1016

GLYCERIN REFINING
PLANT (P2)

CRUDE GLYCERIN
TANKS T-2401, T-2402
CRUDE GLYCERIN
TA1179-D-5212-1016

CRUDE GLYCERIN
TA1179-D-5212-1004

2 "- 24 - 2907 - B001 -NI

2 "- 24 - 1607 - B001 - NI

FAULT
ALARM

SLOP GLYCERIN TANK


T-2301

XA
24031

XS
LOCAL/
REMOTE 24031

2 "- 24 - 1605 - B001 - NI


2"

XL
24031

RUNNING
LIGHT

SLOP GLYCERIN
TA1179-D-5212-1021

2 "- 24 - 2908 - B001 -NI


I

HS
24031

PI
24031

NOTE 2

1/2

START/
STOP
PDI
24031

M
2 "- 24 - 2902 - B001 - NI
2"

2 "- 24 - 2903 - B001 - NI

P-2402 A

1/2
2"
2 "- 24 - 2901 - B001 -NI

CRUDE GLYCERIN
TRANSFER PUMP
NOTE 1

5
FAULT
ALARM

XA
24041

XS
LOCAL/
REMOTE 24041

XL
24041

RUNNING
LIGHT
I

HS
24041

PDI
24041

PI
24041

NOTE 2

1/2

START/
STOP

2"
2 "- 24 - 2904 - B001 - NI

2 "- 24 - 2905 - B001 - NI

1/2

P-2402 B
CRUDE GLYCERIN
TRANSFER PUMP
NOTE 1

FAULT
ALARM

XA
24051

XS
LOCAL/
REMOTE 24051

XL
24051

RUNNING
LIGHT
I

HS
24051

PDI
24051

PI
24051

NOTE 2

1/2

START/
STOP

M
6 "- 24 - 2910 - B001 - NI

66""- 24 - 2911 - B001 - NI

RECIRCULATION TO
CRUDE GLYCERIN
TANKS T-2401, T-2402

1/2

P-2403 A
CRUDE GLYCERIN
EXPORT PUMP

CRUDE GLYCERIN
TA1179-D-5212-1016

X "- 24 - 2915 - B001 -NI

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

JETTY

CRUDE GLYCERIN
TA1179-D-5212-1016

CRUDE GLYCERIN
TA1179-D-5212-1001

6"
6 "- 24 - 1606 - B001 - NI

6"
6 "- 24 - 2916 - B001 -NI

CHKD APPD

DATE

REVISIONS

CLIENT :

CRUDE GLYCERIN
TANKS T-2401, T-2402

PT. SMART Tbk.

FAULT
ALARM

6"
6 "- 24 - 2914 - B001 -NI

PMC :

6"
6 "- 24 - 2909 - B001 -NI

XA
24061

XS
LOCAL/
REMOTE 24061

XL
24061

RUNNING
LIGHT
I

CONSULTANT :

HS
24061

ROYAL HASKONINGDHV

TRUCK LOADING BAYS


PI
24061

CRUDE GLYCERIN
TA1179-D-5212-1034

NOTE 2
6"
6 "- 24 - 2917 - B001 -NI

1/2

START/
STOP
PDI
24061

PROJECT :

SMART MARUNDA BIODIESEL PLANT

M
1

TITLE :

6"
6 "- 24 - 2913 - B001 - NI

6 "- 24 - 2912 - B001 - NI

PIPING & INSTRUMENTATION DIAGRAM


CG TRANSFER AND EXPORT PUMPS (B3)

P-2403 B

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

CRUDE GLYCERIN
EXPORT PUMP

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1029

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1030
A

NOT TO SCALE

NOTES :
1. SAMPLE POINT ON PUMP VENT CONNECTION.
2. HOSE CONNECTION TO ALLOW YELLOW GLYCERIN TRANSFER TO
SLOP GLYCERIN TANK T-2301 VIA PUMP P-3501 A OR B.

FAULT
ALARM

XA
35021

XS
LOCAL/
REMOTE 35021

XL
35021

RUNNING
LIGHT
I

HS
35021

PDI
35021

PI
35021

NOTE 1

1/2

START/
STOP

6 "- 35 - 3002 - B001 - IT

4 "- 35 - 3003 - B001 - IT


4"

P-3501 A

1/2

FATTY MATTER
EXPORT PUMP

FATTY MATTER TANK


T-3501
4 "- 35 - 1403 - B001 - IT

FATTY MATTER
TA1179-D-5212-1036

4 "- 35 - 3007 - B001 - IT

44""- 35 - 3006 - B001 - IT

FATTY MATTER
TA1179-D-5212-1024

TRUCK LOADING BAYS


(B6)

6 "- 35 - 3001 - B001 - IT

FAULT
ALARM

35031

XS
LOCAL/
REMOTE 35031

XL
35031

SLOP GLYCERIN TANK


T-2301

XA
RUNNING
LIGHT

FATTY MATTER
TA1179-D-5212-1021

4"
4 "- 35 - 3008 - B001 - IT
I

HS
35031

PDI
35031

PI
35031

NOTE 1

1/2

START/
STOP

M
NOTE 2
4"
4 "- 35 - 3005 - B001 - IT

6 "- 35 - 3004 - B001 - IT

1/2

P-3501 B
FATTY MATTER
EXPORT PUMP

PSV
25021

YELLOW GLYCERIN
TANK T-2501

SET PRESSURE
8 BARG

YELLOW GLYCERIN
TA1179-D-5212-1017

2 "- 25 - 3013 - B001 -NI


FAULT
ALARM

XA
25021

XS
LOCAL/
REMOTE 25021

XL
25021

RUNNING
LIGHT
I

GLYCERIN REFINING
PLANT (P2)

PDI
25021

PI
25021

NOTE 1
2 "- 25 - 3011 - B001 -NI

YELLOW GLYCERIN
TANK T-2501
YELLOW GLYCERIN
TA1179-D-5212-1017

YELLOW GLYCERIN
TA1179-D-5212-1004

2 "- 25 - 1703 - B001 - NI

2 "- 25 - 3009 - B001 - NI

P-2501

2 "- 25 - 3010 - B001 -NI

NOTE 2

HS
25021

1/2

START/
STOP

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


PMC :

GLYCERIN SLOP TANK


T-2301

YELLOW
GLYCERIN
TRANSFER PUMP

YELLOW GLYCERIN
TA1179-D-5212-1021

2 "- 25 - 3012 - B001 -NI

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

PIPING & INSTRUMENTATION DIAGRAM

FATTY MATTER + YELLOW GLYCERIN PUMPS (B3)


PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1030

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1031
A

NOT TO SCALE

NOTES :
1. SAMPLE POINT ON PUMP VENT CONNECTION.

FAULT
ALARM

XA
33031

XS
LOCAL/
REMOTE 33031

XL
33031

RUNNING
LIGHT
I

HS
33031

PDI
33031

PI
33031

NOTE 1

1/2

START/
STOP

M
4 "- 33 - 3102 - B001 - NI

33""- 33 - 3103 - B001 - NI

REFINED GLYCERIN
DAY TANKS
T-3301, T-3302

SET PRESSURE
8 BARG

PSV
33031

P-3301 A

1/2

REFINED GLYCERIN
DAY TANK
TRANSFER PUMP

REFINED GLYCERIN
TANKS
T-3311 TO T-3314
REFINED GLYCERIN
TA1179-D-5212-1019

3 "- 33 - 3107 - B001 -NI


3 "- 33 - 1805 - B001 - NI

33""- 33 - 3106 - B001 -NI

REFINED GLYCERIN
TA1179-D-5212-1018

REFINED GLYCERIN
TA1179-D-5212-1018

2 "- 33 - 3116 - B001 -NI

REFINED GLYCERIN
DAY TANKS
T-3301, T-3302

4 "- 33 - 3101 - B001 - NI

FAULT
ALARM

XA
33041

XS
LOCAL/
REMOTE 33041

XL
33041

RUNNING
LIGHT
I

CRUDE GLYCERIN
TANKS T-2401, T-2402

HS
33041

PDI
33041

PI
33041

NOTE 1

1/2

START/
STOP

OFFSPEC RG
TA1179-D-5212-1016

3 "- 33 - 3108 - B001 -NI

M
4 "- 33 - 3104 - B001 - NI

3"
3 "- 33 - 3105 - B001 - NI

1/2

P-3301 B
REFINED GLYCERIN
DAY TANK
TRANSFER PUMP

FAULT
ALARM

XA
33071

XS
LOCAL/
REMOTE 33071

XL
33071

RUNNING
LIGHT
I

HS
33071

PDI
33071

PI
33071

NOTE 1

1/2

START/
STOP

6 "- 33 - 3110 - B001 - NI

4"
4 "- 33 - 3111 - B001 - NI

P-3303 A

1/2

REFINED GLYCERIN
DRUMMING
TRANSFER PUMP

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

44""- 33 - 3114 - B001 -NI

REFINED GLYCERIN
TA1179-D-5212-1019

REFINED GLYCERIN
TA1179-D-5212-1019

2 "- 33 - 3117 - B001 -NI

4 "- 33 - 1911 - B001 - NI

FAULT
ALARM

XS
LOCAL/
REMOTE 33081

CONSULTANT :

GLYCERIN DRUMMING
PLANT (B7)

HS
33081

PDI
33081

PI
33081

NOTE 1

ROYAL HASKONINGDHV

REFINED GLYCERIN
HOLD

4 "- 33 - 3115 - B001 -NI

PROJECT :

SMART MARUNDA BIODIESEL PLANT

4"
4 "- 33 - 3113 - B001 - NI

6 "- 33 - 3112 - B001 - NI

TITLE :

1/2

P-3303 B
REFINED GLYCERIN
DRUMMING
TRANSFER PUMP

PIPING & INSTRUMENTATION DIAGRAM

RG DAY TANK TRANSFER + DRUMMING PUMPS (B3)


PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

RUNNING
LIGHT

DATE

REVISIONS

PMC :
XL
33081

I
START/
STOP

CHKD APPD

PT. SMART Tbk.

XA
33081

DESCRIPTION

CLIENT :

1/2

REFINED GLYCERIN
TANKS
T-3311 TO T-3314

SET PRESSURE
8 BARG

PSV
33071

REFINED GLYCERIN
TANKS
T-3311 TO T-3314

6 "- 33 - 3109 - B001 -NI

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

TA1179-D-5212-1031

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1032
A

NOT TO SCALE

NOTES :
1. SAMPLE POINT ON PUMP VENT CONNECTION.
2. CONECTION FOR FLUSHING OF PIPING, USING LOW PRESSURE
STEAM (LPS) AND/OR HOT WATER FROM UTILITY STATION.

FAULT
ALARM

XA
33051

XS
LOCAL/
REMOTE 33051

XL
33051

RUNNING
LIGHT
I

HS
33051

PDI
33051

PI
33051

NOTE 1

1/2

START/
STOP

SET PRESSURE
8 BARG

PSV
33051

6"
6 "- 33 - 3203 - B001 - NI

8 "- 33 - 3202 - B001 - NI

2 "- 33 - 3220 - B001 - NI

1/2

P-3302 A
REFINED
GLYCERIN TRUCK
LOADING PUMP

RECIRCULATION / ITT
TO REFINED GLYCERIN
TANKS T-3311 TO T-3314
REFINED GLYCERIN
TA1179-D-5212-1019

6 "- 33 - 3207 - B001 - NI

PDI
33091

REFINED GLYCERIN
TANKS
T-3311 TO T-3314
REFINED GLYCERIN
TA1179-D-5212-1019

TRUCK LOADING BAYS


(B6)
6 "- 33 - 1912 - B001 - NI

6 "- 33 - 3210 - B001 -NI

XA
33061

XS
LOCAL/
REMOTE 33061

XL
33061

6"
6 "- 33 - 3206 - B001 -NI

8 "- 33 - 3201 - B001 -NI

FAULT
ALARM

RUNNING
LIGHT
I

HS
33061

PDI
33061

PI
33061

NOTE 1

STRIPPED GLYCERIN
TO CRUDE GLYCERIN
TANKS T-2401, T-2402

1/2

START/
STOP

F-3301
REFINED
GLYCERIN
PRODUCT FILTER

REFINED GLYCERIN
TA1179-D-5212-1034

6 "- 33 - 3209 - B001 -NI

6 "- 33 - 3208 - B001 -NI

OFFSPEC RG
TA1179-D-5212-1016

4"
4 "- 33 - 3211 - B001 - NI
66""- 33 - 3205 - B001 - NI

8 "- 33 - 3204 - B001 - NI

1/2

P-3302 B
REFINED
GLYCERIN TRUCK
LOADING PUMP

FAULT
ALARM

XA
34031

XS
LOCAL/
REMOTE 34031

XL
34031

RUNNING
LIGHT
I

START/
STOP

HS
34031

PDI
34031

PI
34031

6 "- 34 - 3213 - C001 - IT

44""- 34 - 3214 - C001 - IT

SET PRESSURE
8 BARG

1/2

PITCH GLYCERIN
TANKS T-3401, T-3402

PSV
34031

P-3401 A
PITCH GLYCERIN
TRUCK LOADING
PUMP

PITCH GLYCERIN
TA1179-D-5212-1022

2 "- 34 - 3219 -C001 -NI

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

PITCH GLYCERIN
TA1179-D-5212-1022

DESCRIPTION

NOTE2

4 "- 34 - 2205 - C001 - IT

FAULT
ALARM

XL
34041

PMC :

RUNNING
LIGHT

CONSULTANT :

ROYAL HASKONINGDHV

TRUCK LOADING BAYS


(B6)

HS
34041

PDI
34041

PI
34041

PITCH GLYCERIN
TA1179-D-5212-1034

4 "- 34 - 3218 - C001 - IT

PROJECT :

SMART MARUNDA BIODIESEL PLANT

M
1

TITLE :
6 "- 34 - 3215 - C001 - IT

4"
4 "- 34 - 3216 - C001 - IT

PIPING & INSTRUMENTATION DIAGRAM


RG + PG TRUCK LOADING PUMPS (B3)

1/2

P-3401 B
PITCH GLYCERIN
TRUCK LOADING
PUMP

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

PT. SMART Tbk.

DATE

XA
34041

XS
LOCAL/
REMOTE 34041
START/
STOP

CHKD APPD

REVISIONS

CLIENT :

PITCH GLYCERIN
TANKS T-3401, T-3402

44""- 34 - 3217 - C001 - IT

6 "- 34 - 3212 - C001 - IT

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

TA1179-D-5212-1032

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1033
A

NOT TO SCALE

NOTES :
1. SAMPLE POINT ON PUMP VENT CONNECTION.
2. COMMON SPARE SLOP PUMP, SUITABLE FOR PUMPING OF BOTH
TYPES OF SLOPPED PRODUCT.

SLOP BIODIESEL
TA1179-D-5212-1020

3 "- 22 - 2003 -A001 - IT

SLOP GLYCERIN TANK


T-2301
6

SLOP GLYCERIN
TA1179-D-5212-1021

FAULT
ALARM

XA
22021

XS
LOCAL/
REMOTE 22021

3 "- 23 - 2103 - B001 - IT

XL
22021

RUNNING
LIGHT

6
I

HS
22021

PDI
22021

PI
22021

NOTE 1

1/2

START/
STOP

3"
3 "- 22 - 3302 - A001 - IT

3 "- 22 - 3301 -A001 - IT

1/2

P-2201
SLOP BIODIESEL
TRANSFER PUMP

SLOP BIODIESEL TANK


T-2201
5

2 "- 22 - 3312 - A001 - IT

SLOP BIODIESEL
TA1179-D-5212-1020

BIODIESEL PLANT (P3)


33""- 22 - 3309 - A001 - IT

XL
22031

RUNNING
LIGHT
I

PDI
22031

PI
22031

NOTE 1

1/2

HS
22031

33""- 23 - 3308 - B001 - IT

XS
LOCAL/
REMOTE 22031
START/
STOP

SLOP BIODIESEL
TA1179-D-5212-1005

XA
22031

33""- 22 - 3307 - B001 - IT

FAULT
ALARM

33""- 22 - 3306 - B001 - IT

3 "- 23 - 3305 - B001 - IT

1/2

P-2202
COMMON SPARE
SLOP PUMP
NOTE 2

SLOP GLYCERIN TANK


T-2301
3
2 "- 23 - 3311 - B001 - IT

SLOP GLYCERIN
TA1179-D-5212-1021

BIODIESEL PLANT (P3)


FAULT
ALARM

XA
23011

XS
LOCAL/
REMOTE 23011

XL
23011

RUNNING
LIGHT

33""- 23 - 3310 - B001 - IT

SLOP GLYCERIN
TA1179-D-5212-1005

I
HS
23011

PDI
23011

PI
23011

NOTE 1

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

1/2

START/
STOP

DESCRIPTION

CLIENT :

DATE

PT. SMART Tbk.

33""- 23 - 3304 - B001 - IT

3 "- 23 - 3303 - B001 - IT

CHKD APPD

REVISIONS

P-2301

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

SLOP BIODIESEL TANK


T-2201

PMC :

SLOP GLYCERIN
TRANSFER PUMP

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

PIPING & INSTRUMENTATION DIAGRAM


SLOP PUMPS (B3)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1033

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1034
A

1. TANKER LEVEL HIGH WILL TRIGGER CLOSURE OF SHUTDOWN


VALVE (SDV) AND STOP OF THE TRUCK LOADING PUMP, VIA LEVEL
SWITCH IN TOP LOADING ARM OR PORTABLE LEVEL SWITCH (IN
CASE OF BOTTOM LOADING ARM).
2.TOP LOADING ARM SHALL BE ARTICULATED WITH SELF SEALING
COUPLING.
7

FQ

33151

I
FIC

TT
33151

PI
33151
FCV
33151

3. BOTTOM LOADING ARM SHALL BE ARTICULARED WITH DRY


BREAK COUPLING.

3 "- 33 - 3405 -A001 -NI

CRUDE GLYCERIN
TA1179-D-5212-1029

CG PUMPS P-2403 A&B

BIODIESEL
TA1179-D-5212-1028

BD PUMPS P-3101 A,B&C

FATTY MATTER
TA1179-D-5212-1030

FM PUMPS P-3501 A&B

PITCH GLYCERIN
TA1179-D-5212-1032

PG PUMPS P-3401 A&B

M-3301
TRUCK LOADING PACKAGE
REFINED GLYCERIN

ESV
33151

LSH

L-3301

4. TRUCK LOADING VALVE CONTROLS FLOWRATE, AND SHALL BE


FAIL CLOSE.

33151
ZS

5. LOADING ARM POSITION IS INTERLOCKED WITH TRUCK LOADING


CONTROLLER; LOADING OPERATION CAN ONLY BE DONE WHEN
ARM IS IN CORRECT POSITION.

33151

NOTE 1, 2, 5

FM

4 "- 33 - 3401 - A001 -NI

31151

NOTE 4

DRIP TRAY

6. EMERGENCY STOP (ESD) BUTTONS SHALL BE PROVIDED IN LINE


WITH NFPA 30, AS FOLLOWS:
- 1 X PER LOADING BAY (2 PCS. IN TOTAL)
- 1 X AT A SAFE DISTANCE FROM LOADING BAYS

NOTE 8

DRIP TRAY

M-3302
TRUCK LOADING PACKAGE
REFINED GLYCERIN

NOTES :

SAFE
LOCATION

33151

7. TRUCK LOADING OPERATION BATCH CONTROL SHALL BE BASED


ON MASS FLOW MEASUREMENT.

LSH
33161

8. PUSHING ESD BUTTON WILL STOP ALL TRUCK LOADING


OPERATIONS IN THE LOADING AREA AND CLOSE ESV.

NOTE 1

FQ

9. TRUCK LOADING AREA SHALL BE SLOPED TOWARDS SUMP.


CONCRETE SHALL BE COATED FOR RESISTANCE TO BIODIESEL.

TANK TRUCK
(BY OTHERS)

6"
6 "- 24 - 2917 - B001 -NI

10 "- 31 - 2811 - A001 -NI

4 "- 35 - 3007 - B001 - IT

4 "- 34 - 3218 - C001 - IT

6 "- 33 - 3210 - B001 -NI

33161

I
FIC
33161

TT
33161

PI
33161

I
FCV
33161

ESV

ZS
33161

NOTE 5

33161

L-3302

FM

4 "- 33 - 3402 - A001 -NI

31161

NOTE 4

NOTE 3

NOTE 8

NOTE 9

SLOPE
SUMP
FM

ESD
00011

SAFE
LOCATION

ESD

NOTE7

FQ

33171

3 "- 33 - 3406 - A001 -NI

M-3303
TRUCK LOADING PACKAGE
REFINED GLYCERIN

I
FIC
33171

TT
33171

PI
33171
FCV
33171

ESV
33171

LSH

L-3303

33171
ZS

33171

NOTE 1, 2, 5

FM

4 "- 33 - 3403 - B001 -NI

31171

NOTE 4

DRIP TRAY

NOTE 8

DRIP TRAY

3
I

M-3304
TRUCK LOADING PACKAGE
REFINED GLYCERIN

LSH
33181

NOTE 1

FQ

TANK TRUCK
(BY OTHERS)

33181

I
FIC
33181

TT
33181

PI
33181

I
FCV
33181

33181

ESV

4 "- 33 - 3404 - B001 -NI

ZS
33181

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

DATE

PT. SMART Tbk.

NOTE 3

NOTE 8

CHKD APPD

REVISIONS

CLIENT :

L-3304

33181

NOTE 4

NOTE 5

33181

FM

PMC :

CONSULTANT :

PROJECT :

CRUDE GLYCERIN
TA1179-D-5212-1035

TRUCK LOADING BAYS

BIODIESEL
TA1179-D-5212-1035

TRUCK LOADING BAYS

FATTY MATTER
TA1179-D-5212-1035

TRUCK LOADING BAYS

PITCH GLYCERIN
TA1179-D-5212-1035

TRUCK LOADING BAYS

ROYAL HASKONINGDHV
TRUCK LOADING BAYS
REFINED GLYCERIN
TA1179-D-5212-1035

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

RG PUMPS P-3302 A&B


REFINED GLYCERIN
TA1179-D-5212-1032

NOT TO SCALE

SMART MARUNDA BIODIESEL PLANT


SLOPE

NOTE 9

TITLE :

SUMP

PIPING & INSTRUMENTATION DIAGRAM


TRUCK LOADING BAY 1 & 2 (B5)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1034

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1035
A

CRUDE GLYCERIN
TA1179-D-5212-1034

1. TANKER LEVEL HIGH WILL TRIGGER CLOSURE OF SHUTDOWN


VALVE (SDV) AND STOP OF THE TRUCK LOADING PUMP, VIA LEVEL
SWITCH IN TOP LOADING ARM.
2.TOP LOADING ARM SHALL BE ARTICULATED WITH SELF SEALING
COUPLING.

M-3101
TRUCK LOADING PACKAGE
BIODIESEL

FQ

3. TRUCK LOADING VALVE CONTROLS FLOWRATE AND SHALL BE


FAIL CLOSE.

31131

3 "- 31 - 3505 -A001 -NI

TRUCK LOADING BAYS

BIODIESEL
TA1179-D-5212-1034

TRUCK LOADING BAYS

FATTY MATTER
TA1179-D-5212-1034

TRUCK LOADING BAYS

PITCH GLYCERIN
TA1179-D-5212-1034

TRUCK LOADING BAYS

NOTES :

SAFE
LOCATION

I
FIC
31131

TT
31131

PI
31131
FCV
31131

ESV
31131

L-3101

LSH

ZS

5. EMERGENCY STOP (ESD) BUTTONS SHALL BE PROVIDED IN LINE


WITH NFPA 30, AS FOLLOWS:
- 1 X PER LOADING BAY (2 PCS. IN TOTAL)
- 1 X AT A SAFE DISTANCE FROM LOADING BAYS

31131

NOTE 1, 2, 4

31131

NOTE 3

4. LOADING ARM POSITION IS INTERLOCKED WITH TRUCK LOADING


CONTROLLER, LOADING OPERATION CAN ONLY BE DONE WHEN
ARM IS IN CORRECT POSITION.

31131

FM

4 "- 31 - 3501 - A001 -NI

NOTE 8

6. TRUCK LOADING OPERATION BATCH CONTROL SHALL BE BASED


ON MASS FLOW MEASUREMENT.
DRIP TRAY

DRIP TRAY

7. PUSHING ESD BUTTON WILL STOP ALL TRUCK LOADING


OPERATIONS IN THE LOADING AREA AND CLOSE ESV.

M-2401
TRUCK LOADING PACKAGE
CRUDE GLYCERIN

8. TRUCK LOADING AREA SHALL BE SLOPED TOWARDS SUMP.


CONCRETE SHALL BE COATED FOR RESISTANCE TO BIODIESEL.

FQ

TANK TRUCK
(BY OTHERS)

6"
6 "- 24 - 2917 - B001 -NI

10 "- 31 - 2811 - A001 -NI

4 "- 35 - 3007 - B001 - IT

4 "- 34 - 3218 - C001 - IT

6 "- 33 - 3210 - B001 -NI

24071

I
FIC
24071

TT
24071

L-2401

PI
24071

LSH

24071
ZS

FCV
24071

24071

ESV
24071

NOTE 1, 2, 4

FM

4 "- 24 - 3502 - B001 -NI

24071

NOTE 3

NOTE 8

NOTE 8

SLOPE
SUMP
ESD
00021

SAFE
LOCATION

ESD

NOTE7

FQ

31141

3 "- 31 - 3506 - A001 -NI

M-3102
TRUCK LOADING PACKAGE
BIODIESEL

I
FIC
31141

TT
31141

PI
31141
FCV
31141

ESV
31141

L-3102

LSH

31141
ZS

31141

NOTE 1, 2, 4

FM

4 "- 31 - 3503 - A001 -NI

31141

NOTE 3

DRIP TRAY

NOTE 8

DRIP TRAY

M-2402
TRUCK LOADING PACKAGE
CRUDE GLYCERIN

FQ

TANK TRUCK
(BY OTHERS)

24081

I
FIC
24081

TT
24081

L-2402

PI
24081

LSH

24081
ZS

FCV
24081

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

24081

NOTE 1, 2, 4

DATE

REVISIONS

24081

ESV

CHKD APPD

CLIENT :

FM

4 "- 24 - 3504 - B001 -NI

PT. SMART Tbk.

24081

NOTE 3

NOTE 8

PMC :

CONSULTANT :

PROJECT :

CRUDE GLYCERIN
TA1179-D-5212-1036

TRUCK LOADING BAYS

BIODIESEL
TA1179-D-5212-1036

TRUCK LOADING BAYS

FATTY MATTER
TA1179-D-5212-1036

TRUCK LOADING BAYS

PITCH GLYCERIN
TA1179-D-5212-1036

TRUCK LOADING BAYS

ROYAL HASKONINGDHV
TRUCK LOADING BAYS
REFINED GLYCERIN
TA1179-D-5212-1036

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

TRUCK LOADING BAYS


REFINED GLYCERIN
TA1179-D-5212-1034

NOT TO SCALE

SMART MARUNDA BIODIESEL PLANT


SLOPE

NOTE 8

TITLE :

SUMP

PIPING & INSTRUMENTATION DIAGRAM


TRUCK LOADING BAY 3 & 4 (B5)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1035

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1036
A

CRUDE GLYCERIN
TA1179-D-5212-1035

TRUCK LOADING BAYS

BIODIESEL
TA1179-D-5212-1035

TRUCK LOADING BAYS

FATTY MATTER
TA1179-D-5212-1035

TRUCK LOADING BAYS

PITCH GLYCERIN
TA1179-D-5212-1035

TRUCK LOADING BAYS

1. TANKER LEVEL HIGH WILL TRIGGER CLOSURE OF SHUTDOWN


VALVE (SDV) AND STOP OF THE TRUCK LOADING PUMP, VIA LEVEL
SWITCH IN TOP LOADING ARM.

NITROGEN
COMPRESSED AIR
-

2.TOP LOADING ARM SHALL BE ARTICULATED WITH SELF SEALING


COUPLING.

DOMESTIC WATER
LOW PRESSURE STEAM
-

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

31151

I
FIC

NOTE8

31151

TT
31151

PI
31151
FCV
31151

ESV
31151

L-3103

LSH

6. TRUCK LOADING OPERATION BATCH CONTROL SHALL BE BASED


ON MASS FLOW MEASUREMENT.

31151
ZS

7. PUSHING ESD BUTTON WILL STOP ALL TRUCK LOADING


OPERATIONS IN THE LOADING AREA AND CLOSE ESV.

31151

NOTE 1, 2, 4

8. UTILITY STATION AT TRUCK LOADING AREA SHALL PROVIDE


NITROGEN, COMPRSSED AIR, DOMESTIC WATER AND LOW
PRESSURE STEAM.

FM

4 "- 31 - 3601 - A001 -NI

31151

NOTE 3

NOTE 8

9. TRUCK LOADING AREA SHALL BE SLOPED TOWARDS SUMP.


CONCRETE SHALL BE COATED FOR RESISTANCE TO BIODIESEL.

DRIP TRAY

M-3501
TRUCK LOADING PACKAGE
FATTY MATTER

6"
6 "- 24 - 2917 - B001 -NI

10 "- 31 - 2811 - A001 -NI

4 "- 35 - 3007 - B001 - IT

4 "- 35 - 3218 - C001 - IT

6 "- 33 - 3210 - B001 -NI

DRIP TRAY

5. EMERGENCY STOP (ESD) BUTTONS SHALL BE PROVIDED IN LINE


WITH NFPA 30, AS FOLLOWS:
- 1 X PER LOADING BAY (2 PCS. IN TOTAL)
- 1 X AT A SAFE DISTANCE FROM LOADING BAYS
3 "- 31 - 3605 - A001 -NI

1/2"
1/2"

FQ

3. TRUCK LOADING VALVE CONTROLS FLOWRATE AND SHALL BE


FAIL CLOSE.
4. LOADING ARM POSITION IS INTERLOCKED WITH TRUCK LOADING
CONTROLLER, LOADING OPERATION CAN ONLY BE DONE WHEN
ARM IS IN CORRECT POSITION.

U.S.

M-3103
TRUCK LOADING PACKAGE
BIODIESEL

NOTES :

SAFE
LOCATION

FQ

TANK TRUCK
(BY OTHERS)

35041

I
FIC

35041

TT
35041

L-3501

PI
35041

LSH

35041

ZS
FCV
35041

35041

ESV
35041

NOTE 1, 2, 4

FM

4 "- 35 - 3602 - B001 - IT

35041

NOTE 3

NOTE 8

NOTE 9

SLOPE
SUMP
ESD
00031

SAFE
LOCATION

ESD

NOTE7

FQ

31161

3 "- 31 - 3606 - A001 -NI

M-3104
TRUCK LOADING PACKAGE
BIODIESEL

I
FIC
31161

TT
31161

PI
31161
FCV
31161

ESV
31161

L-3104

LSH

31161
ZS

31161

NOTE 1, 2, 4

FM

4 "- 31 - 3603 - A001 -NI

31161

NOTE 3

DRIP TRAY

NOTE 8

DRIP TRAY

M-3502
TRUCK LOADING PACKAGE
FATTY MATTER

FQ

TANK TRUCK
(BY OTHERS)

35051

I
FIC
35051

TT
35051

L-3502

PI
35051

LSH

35051
ZS

FCV
35051

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

35051

NOTE 1, 2, 4

DATE

REVISIONS

35051

ESV

CHKD APPD

CLIENT :

FM

4 "- 35 - 3604 - B001 - IT

PT. SMART Tbk.

35051

NOTE 3

NOTE 8

PMC :

CONSULTANT :

PROJECT :

CRUDE GLYCERIN
TA1179-D-5212-1037

TRUCK LOADING BAYS

BIODIESEL
TA1179-D-5212-1037

TRUCK LOADING BAYS

FATTY MATTER
TA1179-D-5212-1037

TRUCK LOADING BAYS

PITCH GLYCERIN
TA1179-D-5212-1037

TRUCK LOADING BAYS

ROYAL HASKONINGDHV
TRUCK LOADING BAYS
REFINED GLYCERIN
TA1179-D-5212-1037

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

TRUCK LOADING BAYS


REFINED GLYCERIN
TA1179-D-5212-1035

NOT TO SCALE

SMART MARUNDA BIODIESEL PLANT


SLOPE

NOTE 9

TITLE :

SUMP

PIPING & INSTRUMENTATION DIAGRAM


TRUCK LOADING BAY 5 & 6 (B5)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1036

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1037
A

CRUDE GLYCERIN
TA1179-D-5212-1036

1. TANKER LEVEL HIGH WILL TRIGGER CLOSURE OF SHUTDOWN


VALVE (SDV) AND STOP OF THE TRUCK LOADING PUMP, VIA LEVEL
SWITCH IN TOP LOADING ARM.
2.TOP LOADING ARM SHALL BE ARTICULATED WITH SELF SEALING
COUPLING.

M-3105
TRUCK LOADING PACKAGE
BIODIESEL

FQ

3. TRUCK LOADING VALVE CONTROLS FLOWRATE AND SHALL BE


FAIL CLOSE.

31171

3 "- 33 - 3705 -A001 -NI

TRUCK LOADING BAYS

BIODIESEL
TA1179-D-5212-1036

TRUCK LOADING BAYS

FATTY MATTER
TA1179-D-5212-1036

TRUCK LOADING BAYS

PITCH GLYCERIN
TA1179-D-5212-1036

TRUCK LOADING BAYS

NOTES :

SAFE
LOCATION

I
FIC
31171

TT
31171

PI
31171
FCV
31171

ESV
31171

L-3105

LSH

ZS

5. EMERGENCY STOP (ESD) BUTTONS SHALL BE PROVIDED IN LINE


WITH NFPA 30, AS FOLLOWS:
- 1 X PER LOADING BAY (2 PCS. IN TOTAL)
- 1 X AT A SAFE DISTANCE FROM LOADING BAYS

31171

NOTE 1, 2, 4

31171

NOTE 3

4. LOADING ARM POSITION IS INTERLOCKED WITH TRUCK LOADING


CONTROLLER, LOADING OPERATION CAN ONLY BE DONE WHEN
ARM IS IN CORRECT POSITION.

31171

FM

4 "- 31 - 3701 - A001 -NI

NOTE 8

6. TRUCK LOADING OPERATION BATCH CONTROL SHALL BE BASED


ON MASS FLOW MEASUREMENT.
DRIP TRAY

DRIP TRAY

7. PUSHING ESD BUTTON WILL STOP ALL TRUCK LOADING


OPERATIONS IN THE LOADING AREA AND CLOSE ESV.

M-3401
TRUCK LOADING PACKAGE
CRUDE, PITCH AND YELLOW GLYCERIN,
FATTY MATTER.

6
4 "- 34 - 3705 - C001 - IT

8. TRUCK LOADING AREA SHALL BE SLOPED TOWARDS SUMP.


CONCRETE SHALL BE COATED FOR RESISTANCE TO BIODIESEL.

9. DRAINS AT END OF HEADERS.

4 "- 35 - 3706 - B001 - IT


4 "- 24 - 3707 - B001 -NI
FQ

TANK TRUCK
(BY OTHERS)

34061

I
FIC
34061

TT
34061

L-3401

PI
34061

LSH

34061
ZS

FCV
34061

H-3401

34061

ESV
34061

NOTE 1, 2, 4

FM
34061

4 "- 34 - 3702 - C001 - IT

NOTE 3

NOTE 8

DRIP TRAY

DRIP TRAY

6"
6 "- 24 - 2917 - B001 -NI

10 "- 31 - 2811 -A001 -NI

4 "- 24 - 3218 - C001 - IT

4 "- 35 - 3007 - B001 - IT

DRIP TRAY

6 "- 33 - 3210 - B001 -NI

NOTE 8

SLOPE
SUMP
ESD
00041

SAFE
LOCATION

ESD

NOTE7

M-3106
TRUCK LOADING PACKAGE
BIODIESEL

FQ

31181

3 "- 33 - 3706 - A001 -NI

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

TRUCK LOADING BAYS


REFINED GLYCERIN
TA1179-D-5212-1036

NOT TO SCALE

I
FIC
31181

TT
31181

PI
31181
FCV
31181

ESV
31181

L-3106

LSH

31181
ZS

31181

NOTE 1, 2, 4

FM

4 "- 31 - 3703 - A001 -NI

31181

NOTE 3

DRIP TRAY

NOTE 8

DRIP TRAY

M-3402
TRUCK LOADING PACKAGE
CRUDE, PITCH AND YELLOW GLYCERIN,
FATTY MATTER.

4 "- 34 - 3708 - C001 - IT


4 "- 35 - 3709 - B001 - IT
4 "- 24 - 3710 - B001 -NI

FQ

TANK TRUCK
(BY OTHERS)

34071

I
FIC
34071

TT
34071

L-3402

PI
34071

LSH

34071
ZS

FCV
34071

H-3401

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

34071

NOTE 1, 2, 4

DATE

REVISIONS

34071

ESV

CHKD APPD

CLIENT :

FM

NOTE 3

PT. SMART Tbk.

34071

4 "- 34 - 3704 - C001 - IT

NOTE 8

DRIP TRAY
DRIP TRAY

PMC :

DRIP TRAY

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

NOTE 9

SMART MARUNDA BIODIESEL PLANT


SLOPE

NOTE 8

TITLE :

SUMP

PIPING & INSTRUMENTATION DIAGRAM


TRUCK LOADING BAY 7 & 8 (B5)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1037

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1038
A

NOT TO SCALE

NOTES :
1. CHEMICAL TANKER UNLOADING AREA IS SHELTERED AND
BUNDED.
2. LOADING HOSE MATERIAL SHALL BE SUITABLE FOR HANDLING OF
CHEMICALS, AND HOSE SHALL BE EQUIPPED WITH SELF SEALING
COUPLING.

4. CHECK VALVE SHALL BE SWING TYPE DUE TO POTENTIAL FOR


CLOGGING.
5. TRUCK UNLOADING PUMPS SHALL BE SELF PRIMING TYPE.
6. DELETED
7. NITROGEN CONNECTIONS FOR LINE FLUSHING TO TOP OF PIPE
WITH QUICK COUPLING.
8. FLOW SWITCH SHALL STOP TRUCK UNLOADING PUMP WHEN
DONE, UPON DETECTION OF NO FLOW. TIME DELAY SHALL BE SET
TO ALLOW START OF PUMP.
9. SAFETY SHOWER + EYE WASH SHALL BE LOCATED NEAR
CHEMICAL TRUCK UNLOADING AREA.
10. PUMPS FORESEEN WITH TEMPERATURE SAFETY SWITCH, TO
PROTECT MOTOR FROM DAMAGE AT BLOCKED INLET OR OUTLET.

11. CONCRETE FLOOR SHALL BE FORESEEN WITH CORROSION


RESISTANT LINING, SUITABLE TO WITHSTAND HYDROCHLORIC
ACID, SODIUM HYDROXIDE AND SODIUM METHYLATE.
12. CHEMICAL UNLOADING HOSES SHALL BE CLEARLY IDENTIFIED
OR FORESEEN WITH DEDICATED CONNECTIONS TO AVOID
ACCIDENTAL WRONG LINE-UP.
13. ESD PUSH BUTTON WILL STOP ALL PUMPS IN UNLOADING AREA
(B1).
14. DUMMY HOSE COUPLING, WHEN FLEXIBLE HOSE IS NOT IN USE.
15. TRUCK UNOADING STATION SHALL BE SUITABLE FOR A
MAXIMUM TRUCK SIZE OF 30 M3 ISOTANKERS.
16. TRUCKS SHALL BE SAMPLED PRIOR TO UNLOADING

ESD

ESD

NOTE13

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CLIENT :
FAULT
ALARM

XS
LOCAL/
REMOTE 24011

XL
24011

START/
STOP

PMC :

HS
24011

01
TSH
24011

PDI
24011

NOTE7

PI
24011

CONSULTANT :

FSI

CRUDE GLYCERIN
TANKS T-2401, T-2402

24011

NOTE 4

H-2402
4 "- 24 - 3801 - B001 -NI

4 "- 24 - 3802 - B001 -NI

NOTE2,12

NOTE11

NOTE14

SLOPE

RUNNING
LIGHT
I

TANK TRUCK
(BY OTHERS)

DATE

PT. SMART Tbk.

XA
24011

CHKD APPD

REVISIONS

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

3. DELETED

CANOPY

SLOPE

ROYAL HASKONINGDHV

CRUDE GLYCERIN
TA1179-D-5212-1016

PROJECT :

SMART MARUNDA BIODIESEL PLANT

P-2401
CRUDE GLYCERIN
UNLOADING PUMP
NOTE 5, 10

TITLE :

NOTE11

PIPING & INSTRUMENTATION DIAGRAM


CHEMICAL TRUCK UNLOADING (B1) 2/2

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1038

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

TA1179-D-5212-1039
A

NOT TO SCALE

NOTES :
1. PUMP SUPPLIED BY LURGI.
2. SAMPLE POINT ON PUMP VENT CONNECTION.
3. UTILITY STATION AT PUMP ROOM SHALL PROVIDE NITROGEN,
COMPRESSED AIR, DOMESTIC WATER AND LOW PRESSURE STEAM.
7

4. CONNECTION FOR PIPE PURGING.

FAULT
ALARM

XA
12051

XS
LOCAL/
REMOTE 12051

XL
12051

RUNNING
LIGHT
I

HS
12051

PDI
12051

PI
12051

NOTE 2

1/2

START/
STOP

M
5

5
2 "- 63 - 3902 -A001 - NI

2 "- 63 - 3903 - A001 - NI

516G10 A

1/2

SODIUM HYDROXIDE
TANK T-6301
SODIUM HYDROXIDE
TA1179-D-5212-1010

SODIUM HYDROXIDE
TRANSFER PUMP

GLYCERIN REFINING
PLANT (P2)

NOTE4

2 "- 63 - 1004 - A001 - NI

SODIUM HYDROXIDE
TA1179-D-5212-1004

2 "- 63 - 3907 - A001 -NI

FAULT
ALARM

XA
12061

XS
LOCAL/
REMOTE 12061

XL
12061

2 "- 63 - 3906 -A001 -NI

2 "- 63 - 3901 - A001 -NI

RUNNING
LIGHT
I

HS
12061

PDI
12061

PI
12061

NOTE 2

1/2

START/
STOP

2 "- 63 - 3904 -A001 - NI

2 "- 63 - 3905 - A001 - NI

516G10 B

1/2

THIS DRAWING IS THE PROPERTY OF ROYAL HASKONINGDHV AND ISSUED FOR THE SPECIFIC PROJECT MENTIONED THEREIN, IT IS NOT TO BE USED OR COPIED FOR OTHER PROJECTS UNLESS EXPRESSLY PERMITTED BY ROYAL HASKONINGDHV.

SODIUM HYDROXIDE
TRANSFER PUMP

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

30/10/15

ISSUE FOR BASIC DESIGN (POST-HAZOP)

HVG

HVG

TNB

TNB

18/09/15

ISSUE FOR TENDER

HVG

HVG

TNB

TNB

12/06/15

ISSUE FOR BASIC DESIGN

HVG

HVG

TNB

TNB

03/04/15

DWN

ENG

REV.

DESCRIPTION

CHKD APPD

DATE

REVISIONS

CLIENT :

PT. SMART Tbk.


PMC :

CONSULTANT :

ROYAL HASKONINGDHV
PROJECT :

SMART MARUNDA BIODIESEL PLANT


1

TITLE :

PIPING & INSTRUMENTATION DIAGRAM


CHEMICAL TRANSFER PUMPS 3 (B1)

PROJ. NO.

DRAWING NO.

FILE NAME

SHEET

TA1179
P&ID

D:\BOX SYNC\5T1135 SINARMAS MARUNDA\5T1135 TEAM\0203 BASIC 22.10.2015\5212-1 P&ID\ ; HVG ; 31/03/2015

TA1179-D-5212-1039

1 OF 1

DRAWING SCALE

NTS

PLOT SCALE

A3

REV.

DRAWN BY

HVG

S-ar putea să vă placă și