2. In a VMAX3, which drive configuration will provide the best performance and density?

Explanation
Topic: Identify the best practices for designing a VMAX3 solution
Training: VMAX3 Solutions Design

3. A customer wants to implement SRDF/S for an application. The application is performing at 8000 IOPS and is using many

volumes. The size of the I/O is 8 KB. Thirty percent (30%) of the IOPS are writes. Assume an RA can handle a maximum
of 3,000 8 KB IOPS.
Based on best practice, how many RAs should be recommended?

Explanation
Topic: Design SRDF/S solutions
Training: VMAX3 Solutions Design

4. You need to design a VMAX3 array solution using VMAX Sizer. Which step is optional?

Explanation

Topic: Design VMAX3 solutions using VMAX Sizer


Training: VMAX3 Solutions Design

5. You are designing SRDF/S over Fibre Channel between two VMAX3 arrays. The production and remote data centers are

50 km apart.

What is the expected write response time delay due to latency?

Explanation
Topic: Design SRDF/S solutions
Training: VMAX3 Solutions Design

10. You are in the process of designing a Unisphere for VMAX solution. What is the default performance database port

number?

Explanation
Topic: Describe Unisphere for VMAX functionality, architecture, and installation planning activities
Training: VMAX3 - Unisphere for VMAX Implementation and Management & VMAX3 Configuration Management

11. What is the granularity of FAST data movement requests in a VMAX3 array?

Explanation
Topic: Identify VMAX3 virtual provisioning concepts and automated tiering in VMAX3 arrays
Training: VMAX3 Configuration Management

13. A customer wants to configure a large SRDF deployment between an VMAX3 array and an older VMAX array. The

customer has many different applications and workloads. They want to separate each into its own SRDF group.
What is the maximum number of SRDF groups this configuration will support?

Explanation
Topic: Describe VMAX3 local replication including; TimeFinder SnapVX architecture, features, capabilities and
benefits, and management

Training: VMAX3 Local Replication Fundamentals

14. Which Unisphere for VMAX feature helps determine the performance impact of migrating the workload from one VMAX3

array to another VMAX3 array?

Explanation
Topic: Described how Unisphere for VMAX is used for workload planning
Training: VMAX3 Configuration Management

18. A customer is adding a new database application. You are asked to design a solution to expand the current SRDF/S

implementation on the customers two VMAX3 arrays to account for this growth. As part of the sizing, you notice that the
two RA ports are at 85% utilization.
What information should be provided to the customer regarding this solution?

Explanation
Topic: Design SRDF/S solutions
Training: VMAX3 Solutions Design

20. A TimeFinder SnapVX snapshot has been created for four source volumes on a VMAX3 array at 8 AM. The snapshot is

set to expire at 10 AM. The snapshot is linked in NoCopy mode to target volumes at 9 AM.
What will happen to the snapshot after the expiration time?

Explanation
Topic: Describe TimeFinder SnapVX operations with SYMCLI and Unisphere for VMAX in physical and virtualized
environments
Training: VMAX3 Business Continuity Management

21. A TimeFinder SnapVX snapshot of the Storage Group containing four devices is created at 10 AM. The storage

administrator adds another device to this Storage Group at 2 PM. A restore operation is performed using the snapshot.
What will be the status of the newly added device after the restore session is terminated?

Explanation
Topic: Describe TimeFinder SnapVX operations with SYMCLI and Unisphere for VMAX in physical and virtualized
environments
Training: VMAX3 Business Continuity Management

22. What is the best practice sizing guideline for disk drive utilization on a two-engine VMAX3?

Explanation
Topic: Identify the best practices for designing a VMAX3 solution
Training: VMAX3 Solutions Design

28. SRDF/A has been enabled between two VMAX3 arrays. In the event of DSE activation, which mechanism will throttle

host writes to match the DSE spillover rate?

Explanation
Topic: Describe SRDF operations in synchronous, SRDF/S, and asynchronous, SRDF/A, modes using SYMCLI
and Unisphere for VMAX in physical and virtualized environments
Training: VMAX3 Business Continuity Management

33. An SRDF/S design analysis was performed with BCSD. The Volume Exception tab in BCSD has identified several

volumes. What is a reason for this issue?

Explanation
Topic: Design SRDF/S solutions
Training: VMAX3 Solutions Design

35. You need to design a VMAX3 eNAS solution with VMAX Sizer. Which type of IO Modules can be assigned to a Data

Mover in the Sizer?

Explanation
Topic: Design VMAX3 solutions using VMAX Sizer
Training: VMAX3 Solutions Design

36. What is the benefit of Multi-Cycle mode in SRDF/A?

Explanation
Topic: Describe SRDF operations in synchronous, SRDF/S, and asynchronous, SRDF/A, modes using SYMCLI
and Unisphere for VMAX in physical and virtualized environments
Training: VMAX3 Business Continuity Management

40. You are discussing VMAX3 FAST algorithms with a customer. The customer wants to know more about the relationship

between the Service Level Objectives and the algorithms.

To which SLOs does the SLO response time compliance algorithm apply?

Explanation
Topic: Identify VMAX3 virtual provisioning concepts and automated tiering in VMAX3 arrays
Training: VMAX3 Configuration Management

43. A VMAX3 array has been configured with two Storage Resource Pools (SRP). Source volumes are assigned to SRP_1

and target volumes are assigned to SRP_2. A TimeFinder SnapVX snapshot of the source volumes is linked to the target
volumes in the default mode.
What will happen when there are new host writes to the source volumes?

Explanation
Topic: Describe TimeFinder SnapVX operations with SYMCLI and Unisphere for VMAX in physical and virtualized
environments
Training: VMAX3 Business Continuity Management

44. Which mechanism will TimeFinder SnapVX use under most circumstances to preserve a point-in-time snapshot?

Explanation
Topic: Describe VMAX3 local replication including; TimeFinder SnapVX architecture, features, capabilities and
benefits, and management
Training: VMAX3 Local Replication Fundamentals

45. Which types of workload files does VMAX Sizer support?

Explanation
Topic: Design VMAX3 solutions using VMAX Sizer
Training: VMAX3 Solutions Design