Delivery
Various devices are used for administration of oxygen. In most cases, the oxygen will
first pass through a pressure regulator, used to control the high pressure of oxygen
delivered from a cylinder (or other source) to a lower pressure. This lower pressure is
then controlled by a flowmeter, which may be preset or selectable, and this controls the
flow in a measure such as litres per minute (lpm). The typical flowmeter range for
medical oxygen is between 0 and 15 lpm with some units able to obtain up to 25 liters per
minute. Many wall flowmeters using a Thorpe tube design are able to be dialed to "flush"
which is beneficial in emergency situations.
which is similar to the partial rebreathing mask except it has a series of one-way valves
preventing exhaled air from returning to the bag. There should be a minimum flow of 10
L/min. The delivered FIO2 of this system is 60-80%, depending on the oxygen flow and
breathing pattern.[9][10] High flows of warmed and humidified air/oxygen blends can also
be delivered via a nasal cannula, allowing the patient to continue to talk, eat and drink
while still receiving the therapy.[11]
In specialist applications such as aviation, tight fitting masks can be used, and these also
have applications in anaesthesia, carbon monoxide poisoning treatment and in hyperbaric
oxygen therapy
mask itself. These masks first became popular in the Toronto (Canada) healthcare
community during the 2003 SARS Crisis. SARS was identified as being respiratory
based and it was determined that conventional oxygen therapy devices were not designed
for the containment of exhaled particles.[13][14][15] Common practices of having suspected
patients wear a surgical mask was confounded by the use of standard oxygen therapy
equipment. In 2003, the HiOx80 oxygen mask was released for sale. The HiOx80 mask is a
closed design mask that allows a filter to be placed on the exhalation port. Several new
designs have emerged in the global healthcare community for the containment and
filtration of potentially infectious particles. Other designs include the ISO-O2 oxygen
mask,the Flo2Max oxygen mask, and the O-Mask. The use of oxygen masks that are
capable of filtering exhaled particles is gradually becoming a recommended practice for
pandemic preparation in many jurisdictions.
Because filtered oxygen masks use a closed design that minimizes or eliminates
inadvertent exposure to room air, delivered oxygen concentrations to the patient have
been found to be higher than conventional non-rebreather masks, approaching 99% using
adequate oxygen flows. Because all exhaled particles are contained within the mask,
nebulized medications are also prevented from being released into the surrounding
atmosphere, decreasing the occupational exposure to healthcare staff and other patients.
act as a fuel; and therefore the design and manufacture of O2 systems requires special
training to ensure that ignition sources are minimized.[29]
Hospitals in some jurisdictions, such as the UK, now operate no-smoking policies,
which although introduced for other reasons, supports the aim of keeping ignition sources
away from medical piped oxygen. Other recorded sources of ignition of medically
prescribed oxygen include candles, aromatherapy, medical equipment, cooking, and
unfortunately, deliberate vandalism. Smoking pipes, cigars and cigarettes are of special
concern. This does not entirely eliminate the risk of injury with portable oxygen systems,
especially if compliance is poor.[30]