Documente Academic
Documente Profesional
Documente Cultură
Foto:HELUKABEL
HELUKABEL
The future reliability of any installation depends on the correct choice of cable used in the network technique. It is only by careful
selection of the components that compliance with the continually increasing requirements placed upon the quality of the network
is possible. Infrastructures based on copper are continually nearing their physical limits because of the rapidly growing demands
from multimedia developments, and hence an alternative to copper must be provided for installations in the future.
The benets of optical bre technology are obvious: High transmission rates, low attenuation, no electromagnetic problems, small
dimensions and low weight. Modern designs for optical bre cables of the HELUCOM series exhibit the same robustness as a
copper cable. The cable constructions are selected for optimum protection of the optical bres in each application.
Within the HELUCOM series, optical bre cables are available with the common bre types of 50/125m, 62,5/125m, 9/125m,
200/230m and 980/1000m. The HELUCOM optical bre cables are manufactured in accordance with the standards and regulations
of DIN VDE 0888.
R4
R5
Page
R6
R7
R8
R9
R 10
R 11
R 12
R 13
R 14
R 15
R 16
R 17
R 18
R 19
R 20
R 21
R 22
R 23
R 24
R 25
R 26
R 27
R 28
R 29
R 30
R 31
R 32
R 33
R 34
R 35
R 36
R 37
R 38
R 39
R 40
R 41
R 42
R 43
R 44
R 45
R 46
R 47
Cable structure
Temperature range
Other data
Laying, min.: 0C
Laying, max.: +50C
Operating, min.: 0C
Operating, max.: +60C
Designation
Outer
Max.
approx. mm tensile
force N
I-VH
I-VH
I-VH
I-VH
I-VH
I-VH
I-V11Y
I-V11Y
I-V11Y
I-VHH
I-VHH
I-VHH
I-V11Y11Y
I-V11Y11Y
I-V11Y11Y
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2,6
2,6
2,6
2,6 x 5,6
2,6 x 5,6
2,6 x 5,6
2,6 x 5,6
2,6 x 5,6
2,6 x 5,6
3,6 x 6,2
3,6 x 6,2
3,6 x 6,2
3,6 x 6,2
3,6 x 6,2
3,6 x 6,2
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
300
300
300
400
400
400
400
400
400
600
600
600
600
600
600
Min. stat.
Caloric load Max.
bending radius approx. MJ / transverse
mm
m
pressure
N / cm
40
0,17
10
40
0,17
10
40
0,17
10
40
0,24
10
40
0,24
10
40
0,24
10
40
2,80
20
40
2,80
20
40
2,80
20
50
0,57
20
50
0,57
20
50
0,57
20
60
4,20
20
60
4,20
20
60
4,20
20
Weight
kg / km
8,7
8,7
8,7
17,5
17,5
17,5
14,0
14,0
14,0
20,0
20,0
20,0
16,0
16,0
16,0
Part no.
80783
80782
80784
80316
80699
80785
82408
82410
82411
80789
80790
80791
82409
81900
82412
Application
These HELUCOM one-fibre and two-fibre (duplex) cables are used for fixed indoor installation, such as in cable ducts. These cables are also
used as ready-made cables (pigtails) that are spliced to fixed cables or as connection cables (jumper cable) as well as for switch frames. The
small diameter and the high flexibility make these cables ideal for the application in switch frames as well as for the connection of terminals.
R6
I-V(ZN)HH
Cable structure
Temperature range
Other data
Laying, min.: 0C
Laying, max.: +50C
Operating, min.: 0C
Operating, max.: +60C
Designation
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
7,1
7,1
7,1
7,1
7,1
7,1
8,4
8,4
8,4
9,3
9,3
9,3
9,6
9,6
9,6
15,0
15,0
15,0
17,5
17,5
17,5
Max.
tensile
force N
1000
1000
1000
1000
1000
1000
1350
1350
1350
1500
1500
1500
2350
2350
2350
2400
2400
2400
2400
2400
2400
Min. stat.
bending
radius
mm
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
330,0
330,0
320,0
Weight
kg / km
40,0
40,0
40,0
45,0
45,0
45,0
70,0
70,0
70,0
100,0
100,0
100,0
165,0
165,0
165,0
170,0
170,0
170,0
220,0
220,0
220,0
Part no.
80743
80799
80813
80753
80800
80814
80754
80769
80815
80688
80801
80816
80795
80803
80818
80796
80804
80819
80798
80806
80821
Application
HELUCOM breakout cables are designed to replace splicing on-site. They are mainly used in indoor applications for small and medium
transmission lines. The fibre-optic connectors are be mounted directly to the individual cables. Therefore no splicing and no splice boxes
are necessary. Pre-assembled cables only need to be laid on site and are immediately functional.
R7
I-V(ZN)H
Cable structure
Temperature range
Other data
Designation
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4,0
4,0
4,0
4,8
4,8
4,8
5,3
5,3
5,3
5,3
5,3
5,3
6,0
6,0
6,0
7,0
7,0
7,0
Max.
tensile
force N
400
400
400
400
400
400
400
400
400
500
500
500
600
600
600
800
800
800
Min. stat.
bending
radius
mm
60,0
60,0
60,0
70,0
70,0
70,0
80,0
80,0
80,0
80,0
80,0
80,0
90,0
90,0
90,0
110,0
110,0
110,0
Weight
kg / km
15,0
15,0
15,0
19,0
19,0
19,0
23,0
23,0
23,0
25,0
25,0
25,0
32,0
32,0
32,0
40,0
40,0
40,0
Part no.
80435
80434
80433
80432
80431
80430
80429
80428
80427
80426
80425
80424
80423
80422
80421
80420
80419
80418
Application
These HELUCOM fibre-optic cables are used for the data network cabling in indoor applications. A big advantage of this cable type is its
space-saving construction. Similar to the breakout cable, the connector is directly mounted at the tight buffer.
R8
I-D(ZN)H
Cable structure
Temperature range
Other data
Designation
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G50/125
Multimode G62.5/125
Multimode G62.5/125
Single-mode E9/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
4
4
4
6
6
6
8
8
8
10
10
10
12
12
12
16
16
16
12
24
12
24
12
24
12
12
12
12
12
12
12
12
12
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
12,5
9,0
12,5
9,0
12,5
9,0
13,5
13,5
13,5
13,5
13,5
13,5
13,5
13,5
13,5
Max.
tensile
force N
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
3000
1600
3000
1600
3000
1600
3000
3000
3000
3000
3000
3000
3000
3000
3000
Min. stat.
bending
radius
mm
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
190,0
140,0
190,0
140,0
190,0
140,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
Weight
kg / km
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
135,0
135,0
135,0
150,0
135,0
150,0
135,0
150,0
135,0
160,0
160,0
160,0
160,0
160,0
160,0
170,0
170,0
170,0
Part no.
80631
80882
80896
80868
80883
80897
80869
80884
80898
80793
80885
80899
80045
80879
80880
80870
80886
80900
80872
80871
80888
81246
80902
80901
80875
80891
80905
80877
80893
80907
80878
80894
80908
Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor
cabling of buildings and facilities. The halogen-free version is especially suitable for the application in skyscrapers, hospitals and stores as
well as in facilities with high concentration of capital goods, such as power plants, computing centers, and at locations with high security
requirements, such as underground and control stations.
R9
A/I-VQ(ZN)BH
Cable structure
Temperature range
Other data
Designation
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
6,1
6,1
6,1
6,6
6,6
6,6
6,6
6,6
6,6
8,0
8,0
8,0
8,3
8,3
8,3
Max.
tensile
force N
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
3000
3000
3000
Min. stat.
bending
radius
mm
90,0
90,0
90,0
100,0
100,0
100,0
100,0
100,0
100,0
120,0
120,0
120,0
125,0
125,0
125,0
Weight
kg / km
40,0
40,0
40,0
47,0
47,0
47,0
51,0
51,0
51,0
65,0
65,0
65,0
70,0
70,0
70,0
Part no.
82804
82809
82814
82805
82810
82815
82806
82811
82816
82807
82812
82817
82808
82813
82818
Application
These HELUCOM fibre-optic cables are used for the data network cabling in indoor and outdoor applications. With their black UV-resistant
outer sheath and the non-metallic rodent protection, they are perfectly suited for outdoor use. A big advantage of this cable type is its
space-saving construction. Similar to the breakout cable, the connector is directly mounted at the tight buffer.
R 10
pact
A/I-DQ(ZN)BH
Cable structure
Temperature range
Other data
Designation
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
4
4
4
6
6
6
8
8
8
12
12
12
24
24
24
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
8,5
8,5
8,5
Max.
tensile
force N
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
Min. stat.
bending
radius
mm
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
170,0
170,0
170,0
Weight
kg / km
Part no.
55,0
55,0
55,0
55,0
55,0
55,0
55,0
55,0
55,0
55,0
55,0
55,0
75,0
75,0
75,0
82792
82796
82800
82793
82797
82801
82794
82798
82802
82795
82799
82803
802143
802144
802145
Application
These HELUCOM pact fibre-optic cables have a small but robust construction. They are suitable for indoor and outdoor cabling of buildings
and facilities when space is an important argument. They are used in particular if the installation is to be done in one piece from the inside
to the outside without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they
are perfectly suited for outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.
R 11
pact
A/I-DQ(ZN)BH OM3
Cable structure
Temperature range
Other data
Designation
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
Multimode G50/125
Multimode G50/125
Multimode G50/125
Multimode G50/125
Multimode G50/125
Number of Outer
fibres per approx.
core
mm
4
6
8
12
24
7,5
7,5
7,5
7,5
8,5
Max.
tensile
force N
1500
1500
1500
1500
1500
Min. stat.
bending
radius
mm
150,0
150,0
150,0
150,0
170,0
Weight
kg / km
Part no.
55,0
55,0
55,0
55,0
75,0
802247
802277
802278
802248
802249
Application
These HELUCOM pact fibre-optic cables have a small but robust construction. They are suitable for indoor and outdoor cabling of buildings
and facilities when space is an important argument. They are used in particular if the installation is to be done in one piece from the inside
to the outside without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they
are perfectly suited for outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.
R 12
A/I-DQ(ZN)BH, central
Cable structure
Temperature range
Other data
Designation
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Number of Outer
fibres per approx.
core
mm
4
4
4
6
6
6
8
8
8
12
12
12
16
16
16
24
24
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
Max.
tensile
force N
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
Min. stat.
bending
radius
mm
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
Weight
kg / km
125,0
125,0
125,0
125,0
125,0
125,0
125,0
125,0
125,0
125,0
125,0
125,0
145,0
145,0
145,0
145,0
145,0
Part no.
80270
80276
80264
80271
80265
80272
80273
80274
80275
80681
80278
80279
80280
80281
80851
80725
82431
Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor and
outdoor cabling of buildings and facilities. They are used in particular if the installation is to be done in one piece from the inside to the
outside without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are
perfectly suited for outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.
R 13
A/I-DQ(ZN)BH, stranded
Cable structure
Temperature range
Other data
Designation
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
11,0
11,0
11,0
11,0
11,0
11,0
11,0
11,0
11,0
11,0
11,5
11,5
11,5
12,5
12,5
12,5
12,5
12,5
12,5
Max.
tensile
force N
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
3000
3000
3000
3000
3000
3000
Min. stat.
bending
radius
mm
165,0
165,0
165,0
165,0
165,0
165,0
165,0
165,0
165,0
165,0
175,0
175,0
175,0
190,0
190,0
190,0
190,0
190,0
190,0
Weight
kg / km
Part no.
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
100,0
100,0
100,0
130,0
130,0
130,0
130,0
130,0
130,0
81495
802263
80846
802261
802264
802266
802281
802262
802265
802267
802268
802271
802274
802269
802272
802275
802270
802273
802276
Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor and
outdoor cabling of buildings and facilities. They are used in particular if the installation is to be done in one piece from the inside to the
outside without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are
perfectly suited for outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.
R 14
FS30
A-DQ(ZN)BH
Cable structure
Temperature range
Other data
Designation
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
4
4
4
12
12
12
7,8
7,8
7,8
7,8
7,8
7,8
Max.
tensile
force N
1000
1000
1000
1000
1000
1000
Min. stat.
bending
radius
mm
80,0
80,0
80,0
80,0
80,0
80,0
Weight
kg / km
Part no.
102,0
102,0
102,0
102,0
102,0
102,0
801217
801218
801219
801220
801221
801190
Application
With the serie HELUCOM E30 we have realized, based on a special construction and high quality raw materials, a functional Integrity according
to DIN 4102-12 E30 (30 minutes). Together with the planed accessories the cables realize the full function of the communication in areas
like tunnels or buildings for the defined period of time. On request we also can deliver cables with more than 12 fibres as stranded construction.
R 15
FS90
A/I-D(ZN)BH(SR)H
Cable structure
Temperature range
Other data
Designation
A/I-D(ZN)BH(SR)H
A/I-D(ZN)BH(SR)H
A/I-D(ZN)BH(SR)H
A/I-D(ZN)BH(SR)H
Multimode G50/125
Single-mode E9/125
Multimode G50/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
4
4
12
12
12,7
12,7
12,7
12,7
Max.
tensile
force N
700
700
700
700
Min. stat.
bending
radius
mm
180,0
180,0
180,0
180,0
Weight
kg / km
Part no.
216,0
216,0
216,0
216,0
803917
803919
803918
803920
Application
With the serie HELUCOM FS90 we have realized, based on a special construction and high quality raw materials, a functional Integrity according
to IEC 60331-25 within 90, minutes (up to 750 C). Together with the planed accessories the cables realize the full function of the communication
in areas like tunnels or buildings for the defined period of time. On request we also can deliver cables with more than 12 fibres as stranded
construction.
R 16
A-DQ(ZN)2Y, central
Cable structure
Temperature range
Other data
Designation
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
6
6
6
8
8
8
12
12
12
16
16
16
24
24
24
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
Max.
tensile
force N
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
Min. stat.
bending
radius
mm
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
Weight
kg / km
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
70,0
70,0
70,0
70,0
70,0
70,0
Part no.
80148
80164
80131
80149
80165
80132
80150
80166
80133
80151
80167
80134
80153
80169
80136
80154
80170
80137
80155
80171
80138
Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount. Around a central grooved cable, there
is a composite of glass yarns and swelling fleece with characteristics that ensure the actual strain relief and waterproofing in longitudinal
direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This construction is
particularly used in underground, tubes and channel areas, where rodent infestation is not to be expected.
R 17
A-DQ(ZN)2Y, stranded
Cable structure
Temperature range
Other data
Designation
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,5
10,5
10,5
11,5
11,5
11,5
11,5
11,5
11,5
13,0
13,0
13,0
13,0
13,0
13,0
14,0
14,0
14,0
Max.
tensile
force N
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
Min. stat.
bending
radius
mm
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
210,0
210,0
210,0
230,0
230,0
230,0
230,0
230,0
230,0
260,0
260,0
260,0
260,0
260,0
260,0
280,0
280,0
280,0
Weight
kg / km
70,0
70,0
70,0
70,0
70,0
70,0
70,0
70,0
70,0
70,0
70,0
70,0
75,0
75,0
75,0
110,0
110,0
110,0
110,0
110,0
110,0
130,0
130,0
130,0
130,0
130,0
130,0
150,0
150,0
150,0
Part no.
80156
80172
80139
80448
80449
80450
80447
80446
80445
80159
80175
80142
80444
80443
80442
80160
80176
80143
80441
80440
80439
80161
80177
80144
80162
80178
80146
80438
80437
80436
Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount and extremely tension-resistant. Around
a stranded grooved cable and filler elements, there is a swelling fleece with characteristics that ensure strain relief and waterproofing in
longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This
construction is particularly used in underground, tubes and channel areas, where above-average tensile stresses and/or transverse compressions
occur, but rodent infestation is not to be expected.
R 18
pact
A-DQ(ZN)B2Y, central
Cable structure
Temperature range
Other data
Designation
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
6
6
6
8
8
8
12
12
12
24
24
24
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
8,5
8,5
8,5
Max.
tensile
force N
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
Min. stat.
bending
radius
mm
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
170,0
170,0
170,0
Weight
kg / km
Part no.
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
60,0
60,0
60,0
800754
802131
802137
800755
802132
802138
800756
802133
802139
800757
802134
802140
800759
802135
802141
802142
800762
802136
Application
These HELUCOM pact fibre-optic cables are characterized by a design that is particularly easy to mount and is rodent-protected. Around a
central grooved cable, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent protection, strain relief,
and waterproofing in longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore
unnecessary. This construction is particularly used in underground, tubes and channel areas, where normal tensile stresses and/or transverse
compressions occur and rodent infestation is to be expected.
R 19
A-DQ(ZN)B2Y, central
Cable structure
Temperature range
Other data
Designation
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
6
6
6
8
8
8
12
12
12
16
16
16
24
24
24
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
Max.
tensile
force N
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
Min. stat.
bending
radius
mm
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
180,0
180,0
180,0
180,0
180,0
180,0
Weight
kg / km
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
130,0
130,0
130,0
130,0
130,0
130,0
Part no.
80196
80212
80180
80197
80213
80181
80198
80214
80182
80199
80215
80183
80201
80217
80185
80202
80218
80186
80204
80220
80187
Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount and is rodent-protected. Around a central
grooved cable, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent protection, strain relief, and
waterproofing in longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore
unnecessary. This construction is particularly used in underground, tubes and channel areas, where normal tensile stresses and/or transverse
compressions occur and rodent infestation is to be expected.
R 20
A-DQ(ZN)B2Y, stranded
Cable structure
Temperature range
Other data
Designation
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
11,0
11,0
11,0
12,0
12,0
12,0
12,0
12,0
12,0
13,5
13,5
13,5
13,5
13,5
13,5
14,5
14,5
14,5
Max.
tensile
force N
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
Min. stat.
bending
radius
mm
210,0
210,0
210,0
210,0
210,0
210,0
210,0
210,0
210,0
210,0
210,0
210,0
220,0
220,0
220,0
240,0
240,0
240,0
240,0
240,0
240,0
270,0
270,0
270,0
270,0
270,0
270,0
290,0
290,0
290,0
Weight
kg / km
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
100,0
100,0
100,0
140,0
140,0
140,0
140,0
140,0
140,0
155,0
155,0
155,0
155,0
155,0
155,0
200,0
200,0
200,0
Part no.
81382
80219
80188
81108
81109
81110
82648
81112
81113
80207
80223
80191
81133
81134
81120
80208
80224
80192
81135
81136
81121
80209
80225
80193
80210
80226
80194
80211
80227
80195
Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount, extremely tension-resistant and
rodent-proof. Around a stranded grooved cable and filler elements, there is a composite of glass yarns and swelling fleece with characteristics
that ensure rodent protection, strain relief, and waterproofing in longitudinal direction of the cable. In addition, these cables are designed
grease-free. Wiping the jelly off is therefore unnecessary. This construction is particularly used in underground, tubes and channel areas,
where above-average tensile stresses and/or transverse compressions occur and rodent infestation is to be expected.
R 21
pact
A-DQ(ZN)B2Y fibre combi, stranded
Cable structure
Temperature range
Other data
Designation
A-DQ(ZN)B2Y
24
A-DQ(ZN)B2Y
24
A-DQ(ZN)B2Y
48
A-DQ(ZN)B2Y
48
Number of Outer
fibres per approx.
core
mm
Max.
tensile
force N
Weight
kg / km
Part no.
90,0
803037
12
9,5
2500
Min. stat.
bending
radius
mm
200,0
12
9,5
2500
200,0
2,50
400
90,0
803923
12
9,5
2500
200,0
2,50
400
90,0
803038
12
9,5
2500
200,0
2,50
400
90,0
803924
Application
These HELUCOM pact fibre-optic cables are characterized by a design that is particularly easy to mount, tension-resistant and rodent-proof.
Around a stranded grooved cable and filler elements, there is a composite of glass yarns and swelling fleece with characteristics that ensure
rodent protection, strain relief and waterproofing in longitudinal direction of the cable. In addition, these cables are designed grease-free.
Wiping the jelly off is therefore unnecessary. This construction is particularly used in underground, tubes and channel areas, where packing
density also plays a role.
R 22
Cable structure
Temperature range
Other data
Designation
A-DQ(ZN)B2Y
24
A-DQ(ZN)B2Y
48
Number of Outer
fibres per approx.
core
mm
Max.
tensile
force N
12
10,5
2700
Min. stat.
bending
radius
mm
200,0
12
10,5
2700
200,0
600
Weight
kg / km
Part no.
95,0
81478
95,0
801183
Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount, extremely tension-resistant and
rodent-proof. Around a stranded grooved cable and filler elements, there is a composite of glass yarns and swelling fleece with characteristics
that ensure rodent protection, strain relief and waterproofing in longitudinal direction of the cable. In addition, these cables are designed
grease-free. Wiping the jelly off is therefore unnecessary. This construction is particularly used in underground, tubes and channel areas,
where above-average tensile stresses and/or transverse compressions occur and rodent infestation is to be expected.
R 23
A-DF(ZN)2Y
Cable structure
Temperature range
Other data
Designation
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
8
8
8
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
10,0
10,0
10,0
10,7
10,7
10,7
11,5
11,5
11,5
14,5
14,5
14,5
Max.
tensile
force N
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
3000
3000
3000
3000
3000
3000
3000
3000
3000
Min. stat.
bending
radius
mm
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
100,0
100,0
100,0
107,0
107,0
107,0
115,0
115,0
115,0
145,0
145,0
145,0
Weight
kg / km
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
90,0
90,0
90,0
120,0
120,0
120,0
135,0
135,0
135,0
175,0
175,0
175,0
Part no.
80016
80033
80000
80017
80034
80001
80019
80036
80003
80021
80038
80005
80024
80041
80008
80912
80913
80914
80026
80046
80010
80027
80047
80011
80473
80474
80475
80028
80048
80012
80777
80774
80764
80032
80051
80015
Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal
direction by filling a jelly mass into the stranding cavities. Non-metallic tension elements ensure above average strain relief. This construction
is particularly used in the area of telecommunication and long distance, but also in regular channels and tubes.
R 24
A-DF(ZN)B2Y
Cable structure
Temperature range
Other data
Designation
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
8
8
8
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
11,0
11,0
11,0
11,5
11,5
11,5
12,0
12,0
12,0
14,5
14,5
14,5
Max.
tensile
force N
2500
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
3000
3000
3000
3000
3000
3000
3000
3000
3000
Min. stat.
bending
radius
mm
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
110,0
110,0
110,0
115,0
115,0
115,0
120,0
120,0
120,0
145,0
145,0
145,0
Weight
kg / km
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
95,0
95,0
95,0
136,0
136,0
136,0
155,0
155,0
155,0
228,0
228,0
228,0
Part no.
80100
80115
80084
80101
80116
80085
80031
80771
80087
80104
80120
80089
80759
80123
80092
81137
81138
81139
80109
80125
80094
80110
80126
80095
81143
81144
81145
80111
80127
80096
81147
81148
81149
80114
80130
80099
Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal
direction by filling a jelly mass into the stranding cavities. Non-metallic tension elements and glass yarns ensure above average strain relief
and rodent protection. This construction is particularly used in the area of telecommunication and long distance, but also in regular channels
and tubes where rodent infestation is possible.
R 25
A-DF(ZN)2Y4Y
Cable structure
Temperature range
Other data
Designation
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
8
8
8
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,5
10,5
10,5
11,0
11,0
11,0
11,5
11,5
11,5
14,5
14,5
14,5
Max.
tensile
force N
2500
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
3000
3000
3000
3000
3000
3000
3000
3000
3000
Min. stat.
bending
radius
mm
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
105,0
105,0
105,0
110,0
110,0
110,0
115,0
115,0
115,0
145,0
145,0
145,0
Weight
kg / km
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
95,0
95,0
95,0
110,0
110,0
110,0
120,0
120,0
120,0
180,0
180,0
180,0
Part no.
80915
80927
80945
80735
80928
80895
80691
80809
80118
80627
80931
80947
80578
80576
80577
80672
80935
80950
80732
80936
80951
80920
80938
80921
80939
80954
80922
80940
80955
80923
80941
80956
80926
80944
80959
Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal
direction by filling a jelly mass into the stranding cavities. Non-metallic tension elements and a second outer sheath made of polyamide (PA)
ensure above average strain relief and rodent protection. This construction is particularly used in the area of telecommunication and long
distance, but also in regular channels and tubes where rodent infestation is possible.
R 26
A-DQ2Y, central
Cable structure
Temperature range
Other data
Designation
A-DQ2Y central
A-DQ2Y central
Single-mode E9/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
4
12
2,5
2,5
Max.
tensile
force N
180
180
Min. stat.
bending
radius
mm
25,0
25,0
Weight
kg / km
6,0
6,0
Part no.
803664
803929
Application
These HELUCOM micro fibre-optic cables are characterized by a design that is slim but robust. Around a central tube, there is a composite
of swelling fleece with characteristics that ensure the strain relief, and waterproofing in longitudinal direction of the cable. This construction
is particularly used in tubes and channels. These cables can be blowing into microducts.
R 27
A-DQ2Y, stranded
Cable structure
Temperature range
Other data
Designation
A-DQ2Y stranded
4
A-DQ2Y stranded
12
A-DQ2Y stranded
24
A-DQ2Y stranded
48
A-DQ2Y stranded
72
A-DQ2Y stranded
96
A-DQ2Y stranded 144
A-DQ2Y stranded 288
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
4
12
12
12
12
12
12
12
6,0
6,0
6,0
6,0
6,0
7,2
9,7
11,2
Max.
tensile
force N
700
700
700
700
700
1000
1200
1500
Min. stat.
bending
radius
mm
60,0
60,0
60,0
60,0
60,0
72,0
97,0
115,0
Weight
kg / km
Part no.
28,0
28,0
28,0
28,0
28,0
44,0
77,0
90,0
803931
803932
803930
803658
803659
803660
803661
803668
Application
These HELUCOM micro fibre-optic cables are characterized by a design that is slim but robust. Around stranded tubes, there is a composite
of swelling fleece with characteristics that ensure the strain relief, and waterproofing in longitudinal direction of the cable. This construction
is particularly used in tubes and channels. These cables can be blowing into microducts.
R 28
A-DQ(ZN)(SR)2Y
Cable structure
Temperature range
Other data
Designation
A-DQ(ZN)(SR)2Y
A-DQ(ZN)(SR)2Y
A-DQ(ZN)(SR)2Y
A-DQ(ZN)(SR)2Y
A-DQ(ZN)(SR)2Y
A-DQ(ZN)(SR)2Y
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Number of Outer
fibres per approx.
core
mm
4
4
4
12
12
12
9,5
9,5
9,5
9,5
9,5
9,5
Max.
tensile
force N
1500
1500
1500
1500
1500
1500
Min. stat.
bending
radius
mm
95,0
95,0
95,0
95,0
95,0
95,0
Weight
kg / km
Part no.
115,0
115,0
105,0
115,0
115,0
115,0
802917
803925
803927
802918
803926
803928
Application
These HELUCOM fibre-optic cables are characterized by a compact construction with a swelling fleece. Above-average rodent protection is
achieved with the metallic rodent protection (steel groove) and an outer sheath made of PE. This construction is particularly used in the
area of telecommunication and long distance, but also in regular channels and tubes where rodent infestation is possible.
R 29
A-DF(ZN)2Y(SR)2Y
Cable structure
Temperature range
Other data
Designation
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Number of Outer
Max.
fibres per approx. mm tensile
core
force N
2
4
12
12
13,0
13,0
13,0
13,0
2700
2700
2700
2700
Min. stat.
bending
radius
mm
130,0
130,0
130,0
130,0
Max.
transverse
pressure
N / cm
800
800
800
800
Weight
kg / km
Part no.
180
180
180
180
82190
800708
800709
800710
Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal
direction by filling a jelly mass into the stranding cavities. Above-average rodent protection is achieved with the metallic rodent protection
(steel groove) and the second outer sheath made of PE. This construction is particularly used in the area of telecommunication and long
distance where ARCOR standards must be followed, but also in regular channels and tubes where rodent infestation is possible.
R 30
A-DSQ(ZN)B2Y
Cable structure
Temperature range
Other data
Designation
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
No. of
fibres
4
4
4
4
4
4
4
4
4
Fibre type
No. of
copper
cores
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
2
2
2
2
2
2
4
4
4
Dimensions
of copper
cores
mm
1,2
1,2
1,2
1,5
1,5
1,5
1,5
1,5
1,5
Outer
approx.
mm
12,0
12,0
12,0
12,5
12,5
12,5
17,0
17,0
17,0
Max.
Min. stat. Caloric load
tensile bending approx. MJ /
force N radius
m
mm
2100
300
4,80
2100
300
4,80
2100
300
4,80
2300
320
4,80
2300
320
4,80
2300
320
4,80
2600
430
5,80
2600
430
5,80
2600
430
5,80
Max.
transverse
pressure
N / cm
200
200
200
200
200
200
200
200
200
81209
81255
81256
82561
81257
81258
82786
81259
81260
Application
These HELUCOM fibre-optic cables are designed especially for use in fibre-optical temperature measurements, such as monitoring of dams.
The extreme mechanical requirements in these areas are fulfilled by the specially designed cable construction. These lines are hybrid glass
fibre lines with copper cores and a special PE outer sheath.
R 31
A-DSF(L)(ZN)2Y
Cable structure
Temperature range
Other data
Designation
No. of
fibres
Fibre type
No. of
copper
cores
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
12
12
24
24
48
48
60
60
72
72
96
96
120
120
144
144
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
2
4
2
4
2
4
2
4
2
4
2
4
2
4
2
4
Dimensions
of copper
cores
mm
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
Outer
approx.
mm
12,0
12,0
13,1
13,1
13,1
13,1
14,1
14,1
14,8
14,8
16,6
16,6
18,4
18,4
20,3
20,3
Max.
Min. stat. Caloric load
tensile bending approx. MJ /
force N radius
m
mm
2500
200
4,80
2500
200
4,80
2500
200
4,80
2500
200
4,80
2500
200
4,80
2500
200
4,80
2500
230
4,80
2500
230
4,80
2500
240
5,10
2500
240
5,10
3000
280
6,30
3000
280
6,30
3000
290
8,50
3000
290
8,50
3500
310
10,00
3500
310
10,00
Max.
transverse
pressure
N / cm
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
80495
80497
800753
801182
80501
80503
80504
80506
80507
80509
80510
80512
80513
80515
80516
80518
Application
These HELUCOM outdoor cables are designed for use under extreme environmental conditions. With the double jelly filling and the Al/PE
laminated sheath, they are water proof in longitudinal and transverse direction. The welded Al tape acts as an additional vapour barrier.
These cables can be layed directly in the ground, in tubes and in ducts. They are mainly used in local and long-distance networks.
R 32
ADSS
Cable structure
Temperature range
Other data
Designation
Number of
fibres
Fibre type
Max.
tensile
force N
Outer
approx.
mm
Weight
kg / km
Part no.
13,6
13,6
15,6
15,6
15,0
20,8
135
137
177
178
161
316
82390
82391
82392
82393
82394
82395
ADSS 9
ADSS 9
ADSS 9
ADSS 9
ADSS 9
ADSS 9
12
24
36
48
60
144
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
4
4
6
8
12
12
150
150
150
150
150
150
9
9
9
9
9
9
ADSS 16
ADSS 16
ADSS 16
ADSS 16
ADSS 16
ADSS 16
12
24
36
48
60
144
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
4
4
6
8
12
12
350
350
350
350
350
350
16
16
16
16
16
16
0,3
0,3
0,3
0,3
0,3
0,3
430
430
500
500
480
650
14,4
14,4
16,4
16,4
15,8
21,6
162
165
200
201
184
333
82396
82397
82398
82399
82400
82401
ADSS 35
ADSS 35
ADSS 35
ADSS 35
ADSS 35
ADSS 35
12
24
36
48
60
144
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
4
4
6
8
12
12
700
700
700
700
700
700
35
35
35
35
35
35
0,35
0,35
0,35
0,35
0,35
0,35
520
520
580
580
560
730
17,2
17,2
19,2
19,2
18,6
24,4
198
200
240
241
227
381
82402
82403
82404
82405
82406
82407
Application
These HELUCOM outdoor cables designed as aerial cables for freely suspended installations on posts and masts. The construction is waterproof
in longitudinal direction thanks to the use of jelly-filled bundle cores and swelling tape. The outer jacket is UV-resistant and at the same time
provides protection against environmental influences, such as snow, ice, sun insolation and wind.
R 33
A-V(ZN)11Y
Cable structure
Temperature range
Other data
Designation
Fibre-optic cable
Fibre-optic cable
Fibre-optic cable
Fibre-optic cable
Fibre-optic cable
Fibre-optic cable
Fibre-optic cable
2
2
4
4
4
8
8
Multimode G50/125
Multimode G62.5/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Outer
approx.
mm
5,0
5,0
5,8
5,8
5,8
7,0
7,0
Outer
sheath
material
Inner
sheath
material
PUR
PUR
PUR
PUR
PUR
PUR
PUR
Min. stat.
bending
radius
mm
75
75
90
90
90
105
105
Flame
proof
halogenfree
UL
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no
no
20
20
31
31
31
47
47
80382
80363
80534
81036
801727
81037
81038
Application
These HELUCOM cables were designed as mobile field cables. They are easily wound up on a drum and are very tension-proof. As the outer
sheath is tightly anchored on the aramid braiding, it is especially suitable for mobile use. The advantage of these cables is evident especially
where mobile fibre-optic lines are to be installed, such as for drag chains, TV transmission, supervision of protected areas, etc.
R 34
WK
WK - UL/CSA
A-V(ZN)Y
Cable structure
Temperature range
Other data
Laying, min.: 0C
Laying, max.: +50C
Operating, min.: -30C
Operating, max.: +80C
Designation
Fibre-optic cable
Fibre-optic cable
Fibre-optic cable
4
4
4
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Outer
approx.
mm
7,0
7,0
7,0
Outer
sheath
material
Inner
sheath
material
PVC
PVC
PVC
Min. stat.
bending
radius
mm
75
75
75
Flame
proof
halogenfree
UL
yes
yes
yes
no
no
no
yes
yes
yes
50
50
50
802792
803934
803935
Application
These HELUCOM cables were designed as mobile field cables. They are easily wound up on a drum and are very tension-proof. As the outer
sheath is tightly anchored on the aramid braiding, it is especially suitable for mobile use. The advantage of these cables is evident especially
where mobile fibre-optic lines are to be installed, such as windturbine projects, TV transmission, supervision of protected areas, etc.. This
series with PVC jacket is certified according the UL/CSA standard OFNG/ FT4.
R 35
WK
AT-V(ZN)H(ZN)11Y, AT-V(ZN)Y(ZN)Y
Cable structure
Temperature range
Other data
Designation
AT-V(ZN)H(ZN)11Y
AT-V(ZN)Y(ZN)Y
AT-V(ZN)H(ZN)11Y
AT-V(ZN)Y(ZN)Y
4
4
12
12
Multimode G50/125
Multimode G50/125
Multimode G50/125
Multimode G50/125
Outer
approx.
mm
8,5
8,5
12,4
12,4
Outer
sheath
material
Inner
sheath
material
PUR
PVC
PUR
PVC
ULSZH
PVC
ULSZH
PVC
Min. stat.
bending
radius
mm
100
130
190
190
Flame
proof
halogenfree
UL
yes
yes
yes
yes
yes
no
yes
no
no
yes
no
yes
125
125
320
320
803346
803348
803347
803349
Application
The HELUCOM WK range is set apart by its extreme rugged yet highly-flexible design. It is used wherever demanding environmental
conditions and extreme movements occur. The tight buffer structure enables the cable to be pre-assembled in-situ with ease. Applications
are for example Windturbines, TV transmissions, mobile field applications, etc..
R 36
WK
AT-V(ZN)YY
Cable structure
Temperature range
Other data
Designation
Fibre-optic cable
Multimode G50/125
Outer
approx.
mm
7,4
Outer
sheath
material
Inner
sheath
material
PVC
PVC
Min. stat.
bending
radius
mm
90
Flame
proof
halogenfree
UL
yes
no
no
65
803364
Application
The HELUCOM range is set apart by its extreme rugged yet flexible design. It is used wherever demanding environmental conditions and
movements occur. The tight buffer structure enables the cable to be pre-assembled in-situ with ease. Applications are for example industry
applications, TV transmissions, etc..
R 37
Cable structure
Temperature range
Other data
Laying, min.: 0C
Laying, min.: +50C
Operating, min.: 0C
Operating, max.: +60C
Designation
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
Number of Outer
fibres per ca. mm
core
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
7,1
7,1
7,1
7,1
7,1
7,1
8,4
8,4
8,4
9,3
9,3
9,3
9,6
9,6
9,6
15,0
15,0
15,0
17,5
17,5
17,5
Max.
tensile
force
N
1000
1000
1000
1000
1000
1000
1350
1350
1350
1500
1500
1500
2350
2350
2350
2400
2400
2400
2400
2400
2400
Min. stat.
bending
radius
mm
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
330,0
330,0
320,0
Weight
kg / km
40,0
40,0
40,0
45,0
45,0
45,0
70,0
70,0
70,0
100,0
100,0
100,0
165,0
165,0
165,0
170,0
170,0
170,0
220,0
220,0
220,0
Part no.
80743
80799
80813
80753
80800
80814
80754
80769
80815
80688
80801
80816
80795
80803
80818
80796
80804
80819
80798
80806
80821
Application
HELUCOM breakout cables are designed to replace splicing on-site. They are mainly used in indoor applications for small and medium
transmission lines. The fibre-optic connectors are be mounted directly to the individual cables. Therefore no splicing and no splice
boxes are necessary. Pre-assembled cables only need to be laid on site and are immediately functional.
R8
AT-VYY
Cable structure
Temperature range
Other data
Designation
AT-VYY
Multimode G62.5/125
Number of Outer
fibres per approx.
core
mm
1
Max.
tensile
force N
Min. stat.
bending
radius
mm
110,0
Weight
kg / km
Part no.
76,0
800126
Application
This HELUCOM fibre-optic cable is suited for fixed installations in pits and channels, but also for flexible applications as jumper cable. Because
of the robust construction with Single- and Overall-jacket you also can use it in industrial areas. With the core-construction, direct plug
manufacturing, even on site, poses no problems.
R 39
I-VH, I-VHH
Cable structure
Temperature range
Other data
Designation
Outer
Max.
approx. mm tensile
force N
I-VH
I-VHH
1
2
2,8
3,8 x 6,6
HCS 200/230
HCS 200/230
300
600
Min. stat.
Caloric load Max.
bending radius approx. MJ / transverse
mm
m
pressure
N / cm
40
0,26
10
50
0,52
10
Weight
kg / km
Part no.
2,8
30,0
800579
81238
Application
These HELUCOM HCS fibre lines are suitable for stationary installation indoors. For heavy-duty mechanical requirements, such as application
in industrial environments, a version with PUR outer sheath is available on request. With a HCS fibre transmission lengths of up to 300m can
be achieved. With the tight buffer construction, direct plug manufacturing, even on site, poses no problems.
R 40
I-V(ZN)Y11Y
Cable structure
Temperature range
Other data
Oil-resistant
Designation
I-V(ZN)Y11Y
HCS 200/230
Number of Outer
fibres per approx.
core
mm
1
7,0
Max.
tensile
force N
800
Min. stat.
bending
radius
mm
50,0
Weight
kg / km
Part no.
43,0
800980
Application
This HELUCOM HCS fibre cable is suitable for fixed installation. Possible applications are normal and heavy-duty mechanical requirements
for example in industrial environments. With the tight buffer construction, direct plug manufacturing, even on site, poses no problems.
With a HCS fibre transmission lengths of up to 300m can be achieved.
R 41
AT-VQH(ZN)B2Y
Cable structure
Temperature range
Other data
Designation
AT-VQH(ZN)B2Y
HCS 200/230
Number of Outer
fibres per approx.
core
mm
1
11,0
Max.
tensile
force N
1500
Min. stat.
bending
radius
mm
200,0
Weight
kg / km
Part no.
90,0
801196
Application
This HELUCOM HCS fibre cable is suitable for fixed installation outdoors. Possible applications are normal and heavy-duty mechanical
requirements for example in industrial environments. This is the reason we also equiped the cable with a non-metallic rodent-protection.With
the tight buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission lengths of up to
300m can be achieved.
R 42
AT-V(ZN)HH
Cable structure
Temperature range
Other data
Designation
AT-V(ZN)HH
HCS 200/230
Number of Outer
fibres per approx.
core
mm
1
9,0
Max.
tensile
force N
800
Min. stat.
bending
radius
mm
225,0
Weight
kg / km
Part no.
76,0
802260
Application
This HELUCOM HCS fibre cable is suitable for fixed and normal flexible installation. Possible applications are normal requirements and also
limited industrial environments. With the tight buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS
fibre transmission lengths of up to 300m can be achieved.
R 43
I-V(ZN)YY
Cable structure
Temperature range
Other data
Designation
I-V(ZN)YY
HCS 200/230
Number of Outer
fibres per approx.
core
mm
1
7,5
Max.
tensile
force N
800
Min. stat.
bending
radius
mm
100,0
Weight
kg / km
Part no.
68,0
801733
Application
This HELUCOM HCS fibre cable is suitable for fixed and normal flexible installations. Possible applications are normal and heavy-duty mechanical
requirements for example in industrial environments. Because of a special PVC jacket this construction is certified by UL (FT1 and FT4). With
the tight buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission lengths of up to
300m can be achieved.
R 44
A/I-DQ(ZN)BH
Cable structure
Temperature range
Other data
Designation
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
HCS 200/230
HCS 200/230
HCS 200/230
HCS 200/230
HCS 200/230
Number of Outer
fibres per approx.
core
mm
4
8
12
8
8
8,5
8,5
8,5
17,7
18,9
Max.
tensile
force N
1500
1500
1500
6000
6000
Min. stat.
bending
radius
mm
130,0
130,0
130,0
265,0
285,0
Weight
kg / km
Part no.
76,0
79,0
82,0
280,0
355,0
801198
802001
802002
802003
802004
Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for fixed indoor
and outdoor cabling of buildings and industry facilities. They are used in particular if the installation is to be done in one piece from the
inside to the outside without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection,
they are perfectly suited for outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.
R 45
I-V2Y, I-V2Y(ZN)11Y
Cable structure
Optical characteristic
Temperature range
Designation
Outer
Jacket
sheath
colour
material
Outer
approx.
mm
I-V2Y 1P 980/1000
I-V2Y 2P 980/1000
I-V2Y(ZN)11Y 1P 980/1000
I-V2Y(ZN)11Y 2P 980/1000
I-V2Y(ZN)11Y 2P 980/1000
I-V2Y(ZN)11Y 4P 980/1000
I-V2Y(ZN)11Y 2P 980/1000 + 2x1mm Cu
I-V2Y(ZN)11Y 2P 980/1000 + 3x1,5mm Cu
PE
PE
PUR
PUR
PUR
PUR
PUR
PUR
2,2
2,2 x 4,4
5,8
6,0
6,0
7,1
7,8
11,0
Black
Black
Violet
Violet
Violet
Violet
Red
Red
Max.
Min. stat.
tensile bending
force N radius
mm
70
25,0
140
25,0
400
30,0
400
31,0
400
31,0
400
45,0
200
70,0
200
70,0
Fibre
Oilattenuation resistant
160A1
160A1
230A1
230A1
230A1
230A1
230A1
230A1
no
no
yes
yes
yes
yes
yes
yes
Acc. to Weight
DESINA kg / km
no
no
yes
yes
yes
yes
no
no
4,0
8,0
30,0
36,0
36,0
65,0
60,0
132,0
Part no.
80532
80388
81611
80629
81882
80630
82032
82033
Application
HELUCOM plastic-fibre cables are used in mechanical engineering, both in mobile and fixed applications. With different constructions, such
as PUR outer sheaths, special strain relief components, hybrid construction with copper cores for power supply or only raw fibre cables,
any possible fields of application are covered. Due to their solidity and their simple adjustability on site, the plastic-fibres (PMMA) are particularly
suitable for applications where trouble-free data transmission in necessary under heavy-duty conditions.
R 46
I-V4Y(ZN)11Y
Cable structure
Optical characteristic
Temperature range
Designation
Outer
Jacket
sheath
colour
material
Outer
approx.
mm
PUR
PUR
PUR
8,0
8,0
6,0
Red
Red
Red
Max.
Min. stat.
tensile bending
force N radius
mm
100
50,0
100
50,0
100
30,0
Fibre
Oilattenuation resistant
160A1
250A1
160A1
yes
yes
yes
Acc. to Weight
DESINA kg / km
no
no
no
42,0
51,0
28,0
Part no.
801200
801201
801202
Application
Signal lines as plastic optical fibre. The use of these transmission systems significantly reduces the number of different cables in a planned
bus installation in machine tools operations. Furthermore, possible EMC problems are prevented by the metal-free construction. The main
application of these cables are in machine construction and automobile industry (PA version).
R 47
Fibrespecications
Granded index bres (multimode)
6SHFLFDWLRQ
)LEUHFDWHUJRULH
&RUHGLDPHWHU
1XPHULFDODSHUWXUH
7\SDWWHQXDWLRQ
0LQEDQGZLGWK
QP
QP
QP
QP
)LEUHW\SH*
206WDQGDUGEUH
P
G%NP
G%NP
0+][NP
0+][NP
)LEUHW\SH*
206WDQGDUGEUH
P
G%NP
G%NP
0+][NP
0+][NP
&ODGGLQJGLDPHWHU
3ULPDU\FRDWLQJGLDPHWHU
&RUHQRQFLUFXODULW\
&ODGGLQJFRQFHQWULFLW\HUURU
&ODGGLQJQRQFLUFXODULW\
6SHFLFDWLRQ
)LEUHFDWHUJRULH
&RUHGLDPHWHU
1XPHULFDODSHUWXUH
7\SDWWHQXDWLRQ
0LQEDQGZLGWK
P
P
P
QP
QP
QP
QP
&ODGGLQJGLDPHWHU
3ULPDU\FRDWLQJGLDPHWHU
&RUHQRQFLUFXODULW\
&ODGGLQJFRQFHQWULFLW\HUURU
&ODGGLQJQRQFLUFXODULW\
206WDQGDUGEUH
P
G%NP
G%NP
0+][NP
0+][NP
P
P
P
)LEUHW\SH*
206WDQGDUGEUH
P
G%NP
G%NP
0+][NP
0+][NP
P
P
P
Single-Mode-Fibre
6SHFLFDWLRQ
)LEUHFDWHUJRULH
$WWHQXDWLRQ
'LVSHUVLRQ
)LEUHW\SH(VLQJOHPRGH
,787*G
G%NP
G%NP
SVQP[NP
SVQP[NP
QP
P
P
P
QP
P
QP
QP
QP
QP
:DYHOHQJWK
0RGHHOGGLDPHWHUDWQP
&ODGGLQJGLDPHWHU
3ULPDU\FRDWLQJGLDPHWHU
&XWRIIZDYHOHQJWK
&ODGGLQJFRQFHQWULFLW\HUURU
&ODGGLQJQRQFLUFXODULW\
QP
QP
QP
QP
)LEUHW\SH32)3
)LEUHW\SH+&6.
P
G%NP
0+][P
P
GENP
G%NP
0+][NP
0+][NP
P
P
)LEUHVZLWKRWKHUSDUDPHWHUHVRQUHTXHVW
R 48
10
11
12
13
14
Lg layerstranding
PVC-sheath
Sheath with halogenfree material
Armouring
Armouring with PVC-protective covering sheath
Armouring with PE-protective covering sheath
Y
PVC-sheath
2Y
PE-sheath
4Y
PA-sheath
11Y
PUR-sheath
(L)2Y
PE-Laminated sheath
(ZN)2Y PE-sheath with nometallic strength member
(L)(ZN)2Y PE-Laminated sheath with nonmetallic strength member
F Filling of the cable core with
petroleum jelly
Q Swellingmaterial
S
V
K
H
W
B
D
I
A
AT
R 49
Tight buffer
Composite buffer bre
Loose buffer nonlled
Loose buffer, lled
Multibre buffer nonlled
Multibre buffer lled
Indoor cable
Outdoor cable
Outdoor fan out cable
R 50