Documente Academic
Documente Profesional
Documente Cultură
Module 3 SF/CPM
Switching Fabric/Central Processor Module
Alcatel University
Page 2
Alcatel University
Module Objectives
Upon successful completion of this module, the student will understand the:
Page 3
Alcatel University
A 200Gb/s switch fabric constructed from multiple independent switching elements. The
switch fabric is responsible for sending cells received on one port out another.
The core control processing for a 7450 ESS node. Control plane processing is carried out by a
Dual Processing Complex (DPC). The DPC uses two identical CPUs that jointly perform all of
the centralized chassis management and implement the bulk of the protocol stacks (OSPF, ISIS, MPLS, etc.). Each CPU uses the switch fabric to send and receive control plane traffic.
The 7450 ESS-7 supports two SF/CPM cards, to provide redundancy. Redundancy means fully
redundant full-duplex switching capacity as well as fully redundant control plane processing.
Additional resiliency is achieved by the fact that the DPC portion of the SF/CPM is not part of the
traffic forwarding plane. This means that traffic on already established routes / paths will not be
disrupted even if the DPC should fail.
The ESS-1 chassis does not use the SF/CPM card. Instead, functionality provided by a separate
SF/CPM and IOM cards on the ESS-7 is integrated into the ESS-1 chassis. A virtual backplane
allows traffic to travel between MDAs. The CPU on the integrated IOM module performs the
protocol stack processing functions performed by the SF/CPM card on the ESS-7.
Page 4
Alcatel University
Page 5
Alcatel University
Captive Screw
Ejector Lever
BITS port
Provisioned with an RJ-45 jack; used for the network clock source.
DCE
DTE
Console
The console port is a serial port with a DB-9 jack. The port is used
for the initial system startup as well as system configuration and monitoring.
AUX
Alarm
ACO/LT
Mgmt. port
10
Link
Amber : 10 Mb/s
Green : 100 Mb/s
Unlit : Operationally down
Data
Page 6
Alcatel University
LEDs
10
3
1
2
Page 7
Alcatel University
Reset
>
Power
>
Status
Green: Operationally up and administratively
up.
Amber: Operationally down but administratively
up.
Unlit: Not operational, shutdown, or
administratively down.
>
Page 8
Alcatel University
>
Timing.
Green: Locked (operational state)
Green (blinking): Clock in (internal) holdover
state
Amber: Alarm condition
Amber (blinking): Clock in free running state
Unlit: Clock not initialized or no SONET ports
are provisioned on the system.
Page 9
Alcatel University
Reference 1
Green: Selected as clock reference input.
Green (blinking): Qualified but set as standby
clock reference.
Amber: Not qualified and in use.
Off: Not in use, not configured.
Reference 2
This LED is lit only on the active CPM.
Reference 3 BITS network clocking
Green: Selected as clock reference input.
Green (blinking): Qualified but set as standby
clock reference.
Amber: Not qualified and in use.
Off: Not in use, not configured.
Page 10
Alcatel University
>
Page 11
Alcatel University
Page 12
Alcatel University
Page 13
Alcatel University
Switch fabric
Switch Fabric
The switch fabric consists of four independent switching elements. The fabric is available at 200
Gb/s full-duplex switching. Each switch fabric element connects to each IOM slot as well as the
DPC of each SF/CPM.
Each switching element of the fabric behaves like a standard crossbar switch, but has the added
ability of allowing each egress port to be scheduled independently of all other ports. This control
over the scheduling of ingress to egress port traffic enables the fabric to guarantee traffic rates
between a given ingress to a given egress port.
Fabric Redundancy
Each switching element (SE) along with its associated serial links is totally independent from all
others. On nodes that have two SF/CPMs, traffic is load shared by both fully operational fabrics.
If a switching element or any of its serial links fail, only traffic that is passing over that link or SE
at the time of the failure is affected. If an SE or any of its links should fail, the fabric is only
degraded by an amount equal to that SE. In most cases this will have no effect on traffic flow as
the switching capacity of each fabric exceeds the total bandwidth needed for all IOMs. This
allows for graceful degradation of a switch fabric rather than catastrophic failure.
Page 14
Alcatel University
Switch Fabric A
FRMR M
D
A
MAC M
D
A
10 Gb/s Fabric
Complex Access
SE
SE
SE
SE
10 Gb/s Fabric
Complex Access
I/O Module 1
MAC M
D
A
10 Gb/s Fabric
Complex Access
10 Gb/s Fabric
Complex Access
I/O Module 10
SE
SE
SE
SE
NP
MEM
CPU-0
CPU-1
Memory
Memory
Switch Fabric B
M
FRMR D
A
TM
FA
FA
TM
NP
MEM
CPU-0
CPU-1
Memory
Memory
SF/CPM B
Under normal operating conditions both Switch Fabrics are load sharing and active,
Initially one CPM complex is active while the second one is in Warm Standby mode
7450 ESS Family SF/CPM Card
Page 15
Alcatel University
Questions
1. Every 7450 ESS uses a SF/CPM card.
a. True
b. False
Page 16
Alcatel University
Page 17
Alcatel University
Answers 9
1. Every 7450 ESS uses a SF/CPM card.
a. True
b. False 3
Page 18