How to fix this alarm "RF UNIT RX CHANNEL RTWP/RSSI Unbalanced " -->
Internal Interference:
The RTWP of main and diversity is usually irrelevant. If the RTWP is relevant, there
must be special causes, such as the main and diversity are combined at
some point.
The interference is related to traffic. The interference occurs less probably when
traffic is lower.
The RTWP fluctuates sharply, as great as about 10 dB, or even greater than 10 dB.
The interference will last for a period, without mutational change, which
is different from that of external interference.
In terms of time feature of RTWP, the RTWP changes irregularly.External
interference:
The interference to main or diversity is relevant. Namely, in terms of time,
the interference to main or diversity trends similarly, and the difference
betweenthem is within 5 dB.
The external interference affects multiple cells that are geographically bordering.
In terms of time feature of RTWP, the external interference is mutational, the
interference occurs at a regular point and in a regular period, and lasts for a
regular period (exceptions are microwave interference, improperly configured
gain of repeaters, so the RTWP is not mutational).
Check interference.(Measure RTWP when there is no load and if it is near -106, you
have no RTWP interference)
Check cell load( If RTWP is higher when user number is higher, you need to
share the load with other cells)
Limit the HSUPA user number if you have 40 or more(go for 35 and lower till yousee
you are reaching an appropriate value)Open features like IC(interference
cancelation) in order to help improve the RTWP.
Open HSPA state transfer( users can go from HSPA to fach) in order to decrease the
load.(check FACH usage as you may need to add another SCCPCH channel).Change
"Inactive timer" UPSINACTIVETIMER from 20s to 10s in order to save channel
resources and release faster the inactive users.If the RTWP is higher than -106 even
during night hours(means no load on the cell) and you cannot find the source of the
interference check "MOD RXBRANCH" in NodeB level and modify RTWPINITADJUST
till a value you get near RTWP(actual value) + (RTWPINITADJUST) = -106.
Check neighbor relations for interference(Usually this is the main cause of RTWP)
Possible Causes.
a
b
c
d
c.The feeder installation is improper. For example, the feeder connector is loose,
soaked or damaged, or the feeder is deformed.
d.The RF unit is faulty.
NSN
PRX total is RTWP
PRN Noise is Noise floor = Thermal Noise + Noise Figure = Background Noise
PRX Noise = Thermal noise + NF
Thermal Noise = -108 dbm
NF= i dont know the exactly value for NSN Noise Figure (you can get in NSN doc)