Table F003-4/E
HYDRAULIC SECTION
1.1
1.2
1.3
1.4
1.5
1.6
1.7
3.1
3.2
3.3
3.4
3.5
3.6
3.7
Standard version
Option /I
Option /Q
Option /F
Option /Z
Command signals wiring
Shield connections
ELECTRONIC SECTION
HYDRAULIC SECTION
ELECTRONIC SECTION
TRANSFORMER
TRANSFORMER
RECTIFIER
RECTIFIER
SUPPRESSOR
FILTER
OVERVOLTAGE
SUPPRESSOR
F003
Suppression of interferences by
electrical noise
When starting the system, it is always advisable to check that feedbacks, references and
signal grounds are free from interferences
and electrical noise which can affect the
characteristics of the signal and generate
instability in the whole system.
Electrical noises are high non-stationary
oscillations both on amplitude and frequency
around the signal average value; they can be
suppressed by shielding and grounding the
signal cables, see section 3.7.
3
3.1
+ 24 V
POWER
SUPPLY
0V
DEAD BAND
10 V (signal)
REFERENCE
SIGNAL
Test
0 V (signal)
GROUND
PROTECTION
ALARM
CONTROLLER
COIL S2
(E-RI-TE-05H)
CONTROLLER
PILOT STAGE
FEEDBACK
(E-RI-LE)
COIL S1
3.2
MAIN STAGE
FEEDBACK
+ 24 V
POWER
SUPPLY
0V
DEAD BAND
420 mA
Test
R = 316 ohm
(max 500 ohm)
REFERENCE
SIGNAL
CURRENT MONITOR (AE)
FEEDBACK MONITOR (TE, LE)
MONITOR
GROUND
PROTECTION
ALARM
CONTROLLER
COIL S2
(E-RI-TE-05H)
CONTROLLER
COIL S1
PILOT STAGE
FEEDBACK
(E-RI-LE)
MAIN STAGE
FEEDBACK
3.3
+ 24 V
POWER
SUPPLY
ENABLE
0V
>9 to +24V
DEAD BAND
10 V
Test
REFERENCE
SIGNAL
0V
MONITOR
ALARM
CONTROLLER
COIL S2
(E-RI-TE-05H)
CONTROLLER
COIL S1
PILOT STAGE
FEEDBACK
(E-RI-LE)
3.4
MAIN STAGE
FEEDBACK
+ 24 V
POWER
SUPPLY
0V
0V
DEAD BAND
10 V
Test
REFERENCE
SIGNAL
0V
MONITOR
GROUND
PROTECTION
ALARM
CONTROLLER
FAULT
COIL S2
(E-RI-TE-05H)
CONTROLLER
COIL S1
PILOT STAGE
FEEDBACK
(E-RI-LE)
3.5
MAIN STAGE
FEEDBACK
+ 24 V
POWER
SUPPLY
0V
ENABLE
>9 to +24V
POSITION S2
10 V
REFERENCE
SIGNAL
POSITION ZERO
0V
FEEDBACK MONITOR 10 V
MONITOR
TEST
MONITOR
OPTION /S
POSITION S1
REPEAT
0V
OPTION /Z
ENABLE
REPEAT ENABLE
>9 to +24V
FAULT
FAULT
TEST
N.C.
ENABLE
N.C.
FAULT
0V or +24V
DEAD
BAND
COIL S2
(E-RI-TE-05H)
CONTROLLER
CONTROLLER
COIL S1
PILOT STAGE
FEEDBACK
(E-RI-LE)
MAIN STAGE
FEEDBACK
F003
3.6
0V
0V
10V
0V
MONITOR
MONITOR
Fig. A
Fig. C
3.7
0V
0V
MONITOR 420mA
MONITOR 420mA
Common zero
SHIELD CONNECTIONS
The correct shielding of signal cables has to be provided to protect the electronics from electrical noise disturbances, which could affect the valve
functioning.
Examples of correct shielding criteria are shown in the following fig. E and F.
The shield connections of fig. G and H must be avoided because they could generate ground loops which enhance the noise effect.
Fig. E
Fig. F
Fig. G
Symbols:
Standard earth
Fig. H
Supply GND
Protected earth
To evaluate the fault and to find the defective component within an electrohydraulic system it is necessary a good cooperation between electronic and
hydraulic engineers.
Besides a good knowledge of the technical tables for each component, for performing analysis of the system it is necessary to evaluate the hydraulic
scheme and the electric wiring diagram related to operation cycle.
There is no general recipe for succes in fault finding due to quite diverse nature of the electrohydraulic systems; however the following table provides a
useful point to start.
Notes:
- Most problems are solved by the replacement of defective components on site. The defective components are then generally repaired by the manufacturer.
- Following tables dont consider any system design fault
4.1 Open loop applications
PROBLEMS
Electrical /Electronic
Defective pump
Air in the circuit
Fluid contaminated
Insufficient piloting pressure of double stage valves
Stick-slip effect due to excessive friction of cylinder seals
Speed below minimum for hydraulic motor
Actuator overrun
Defective pump
Control valve blocked (dirt)
Hand valves and settings not in correct position
Cabling error
Open circuit in electrical control leads
Signalling devices in correctly set or defectives
Lack of electrical power and/or reference signal
Transducers mechanically uncalibrated
Excessive noise
Filters blocked
Foaming of the fluid
Pump or motor mounting loose
Excessive resistance in the suction line
Control valves buzz
Air in the valve solenoid
Electrical /Electronic
F003
Electrical /Electronic
Unstable control
Inhibited control
Bad repeatability
and high hysteresys
04/04
Mechanical/Hydraulic
Electrical /Electronic
Amplitude damping
Wave amplifier
Time delay
Vibrating control