Documente Academic
Documente Profesional
Documente Cultură
Principle
Based on our policy, Quality in Motion,
have minimal impact on the global environment and harmoniously serve people
and buildings with smooth, seamless operation. The refined design produces a
high-quality atmosphere that reassures passengers of the superior safety and
comfort synonymous with Mitsubishi Electric products. Regardless of the use or
purpose, the NEXIEZ is a best-match solution for virtually any elevator installation.
Contents
Main Features
3-4
Car Designs
5-8
Hall Designs
9-10
Features
11
Electrical Installation
12
13-14
15-16
17-18
1.75
NEXIEZ-GPX
Type MR
1.0
450
700
(kg)
750
1.75
NEXIEZ-GPX
Type MRL
1.0
450
1
550
630
825
(kg)
Main Features
Our long-term commitment to developing energy-efficient elevators has created systems and functions that
make intelligent use of power.
NEXIEZ-GPX comes in two types: configurations with and without machine room (Type MR and Type MRL).
Choose the configuration that is better suited for the space and other building conditions.
Permanent magne
I n d u c t i o n m o to r
Motor
2010
20 0 0
1990
1980
Motor drive
AC2 control
Control circuit
AC V V *1 control
100%
t m o to r
V V VF**22 control
Relay
Power consumption /
CO2 emissions*3
Type MRL
(MRL: Machine-room-less)
G e ar l e ss
Worm geared
Traction machine
Type MR
(MR: Machine room)
Microcomputer
93%
74%
37%
30 %
Approx.
70%
Emergency Situations
The joint-lapped core built into the PM motor of the traction machine features flexible
joints. The iron core acts like a hinge, which allows coils to be wound around the
core more densely, resulting in improved motor efficiency and compactness.
A high-density magnetic field is produced, enabling lower use of energy and resources
and reduced CO2 emissions.
Motor
Motor
Control
panel
Control
panel
Switch
LED Lighting
Used for ceiling lights, LEDs boost the overall energy performance of the building.
Furthermore, a long service life eliminates the need for frequent lamp replacement.
To a specified
floor
Switch
Firefighter
Emergency
power supply
Normal
power
supply
Emergency
power supply
Normal
power
supply
To a specified
floor
Advantage of LEDs
Earthquake Emergency Return (EER-S) (Optional)
Ceiling: L500
LED
Incandescent
lamp
14.4
132
Motor
Control
panel
Switch
Normal
power
supply
To the nearest
floor
L500
N520
Ceiling:
Ceiling:
- Brushed stainless-steel
- Brushed stainless-steel
- Brushed stainless-steel
- Brushed stainless-steel
- Brushed stainless-steel
- 69
- Type LCD
Walls
The ceiling height of the car shown in this design image is 2600mm.
N510
N530
Ceiling:
Ceiling:
Walls
Walls
- Decorative plastic
finish (7054-60)
Transom panel
- Brushed stainless-steel
Doors
- Decorative plastic
finish (7054-60)
Front return panels - Brushed stainless-steel
Kickplate
- Brushed stainless-steel
Flooring
- 650
Car operating panel - Type LED
Actual colors may differ slightly from those shown.
Walls, doors
Stainless-steel
Yellow-orange lighting
Illumination
color
Tactile
Stainless-steel with
non-directional brushed f inish
Code No.
All
Type MR
Type MRL
1863K-55
2047-60-100
4166-60
4744-60
4745-60
4746-60
7054-60
7850-60
Y006
Y010
Y017
Y054
Y120
Y010
Y017
Y054
Y120
Painted finish
Configuration
Elevator type*1
D403-60
*2
Location of
car operating panel
Y003
Front return
panel
P08-2S
P11-CO
P11-2S
Front return
panel
P06-2S
P08-CO
Side wall
Transom panel
Stainless-steel
Brushed finish
Flooring
Painted finish
Type LED
Type LCD
Notes:
*1: Appearing fixing method of face plate is slightly different in elevator type.
Please consult our local agents for more details.
*2: The entrance width (JJ) shall be 800mm. For JJ=900mm, please consult our local agents.
69
Interior
602
612
618
650
651
Y003
Y006
Finishes
Application
Mirror
Walls*1
Handrail
Transom panel
Doors
Front return panel
Kickplate
YH-59S
Flooring
Sill
YZ-52A
7
Required
Color No.
Brushed stainless-steel
Decorative plastic finish
Painted steel sheet
Brushed stainless-steel
Painted steel sheet
Brushed stainless-steel
Decorative plastic finish
Painted steel sheet
Brushed stainless-steel
Paint *2
Brushed stainless-steel
Durable vinyl tiles (2mm thick)
Durable rubber tiles (3 or 6mm thick)
Marble (Supplied by customer)
Extruded hard aluminum
Hall Designs
E-102
E-302
Narrow Jamb
Splayed Jamb
Brushed finish
Painted finish
Y003
Jamb
- Painted steel sheet (Y010)
Doors
- Painted steel sheet (Y010)
Hall position indicator
and hall button
- PIV1-A710
Y006
Y010
Brushed stainless-steel
Sill
PIV1-C720
PIV1-C760
Color No.
Doors
Note:
Required
Brushed stainless-steel
Jambs
PIV1-C710
Y120
Finishes
Application
PIV1-A720
Y054
Jamb
- Brushed stainless-steel
Doors
- Brushed stainless-steel
Hall position indicator
and hall button
- PIV1-C710
PIV1-A710
Y017
PIV1-C770
10
Electrical Installation
Features
Abbreviation
1C-2BC
2C-2BC
Required
-
CCBK
GCBK
HCBK
CCC
CFO-A
CLO-A
Continuity of Service
COS
Capacity
(kg)
450
550
EVRC-C
700
FCC-P
Independent Service
IND
Next Landing
NXL
for Type MR
#1
750
OLH
Safe Landing
SFL
Capacity
(kg)
450
FFS
TFS
1C-2BC
2C-2BC
825
SOHS
Abbreviation
1C-2BC
Required
DSAC
DLD
NDG
DODA
ROHB
RDC
Repeated Door-close
630
Required
MFP
Feature
Abbreviation
AECC
CID-S
CTBZ
Type MRL
Inter-communication System #3
Voice Guidance System
Feature
1C-2BC
2C-2BC
11
2.8
3.7
6.5
5.1
8.9
15
20
33
25
42
FLAcc (A)
Capacity of
power supply
(kVA)
Breaker in
control panel
(A)
Heat
emissions
(W)
25
34
58
44
75
4
5
7
6
9
20
30
40
30
50
740
960
1520
1190
1930
Current at 200V
When power is supplied to multiple elevators in a group through a common feeder, the capacity of the power supply
transformer, the size of the feeder, and the current rating of the no-fuse (NF) breaker for one elevator are each multiplied
by the corresponding diversity factor below.
Abbreviation
1C-2BC
2C-2BC
Required
EER-S
FER
Notes:
FLU (A)
1.0
1.0
1.75
1.0
1.75
700
850
1500
1100
1900
1200
2050
The wire length for the feeder size must be calculated via the following formula.
Wire length (m) <
= Coefficient* E (V)/FLAcc (A)
(E: power supply voltage (V))
(FLAcc (A): current while accelerating with full load at power supply voltage of 200V)
*Refer to the table below for coefficients.
ITP
Motor
output
(kW)
20
30
40
30
40
30
50
Required
AAN-G
ECL
Rated
speed
(m/sec)
4
5
7
5
8
6
9
The feeder must be able to withstand continuous flow of the following current at an ambient temperature of 40C.
PIM-C
26
31
52
39
65
41
70
16
19
30
23
38
24
40
Note: If power supply voltage (E) is a value other than 200V, FLU current and FLAcc current are obtained via the following formula.
(FLU/FLAcc current (A) at E (V)) = (Current at 200V) (200/E (V))
Type MR
FLAcc (A)
2.8
3.4
5.9
4.3
7.6
4.6
8.1
Heat
emissions
(W)
FLU: current during upward operation with full load at power supply voltage of 200V.
FLAcc: current while accelerating with full load at power supply voltage of 200V.
FLU (A)
1.0
1.0
1.75
1.0
1.75
1.0
1.75
Capacity of
NF size in
power supply machine room
(A)
(kVA)
Current at 200V
NS
HOS
Motor
output
(kW)
NSCR-C
Feature
Rated
speed
(m/sec)
No. of elevators/group
Diversity factor
2
2.0
FE
MELD
OEPS-SA
The current size of the grounding wire is determined according to the current rating of the NF breaker on the power source side.
The current rating of the NF breaker on the power source side should be one level larger than that on the receiving box side
3.5
6.3
5.5
9.7
8
13.8
14
23.9
22
35.9
30
46.4
38
57.6
50
71.3
60
85
80
105
100
126
125
146
150
166
200
192
250
218
325
244
12
Entrance width: JJ
150
55
E-302
Keyhole
Keyhole
300
25
30
150
150
Finished Min. 50
wall
(by owner)
140 60
Jamb
depth:
min. 130
20
91
10
Entrance width: JJ
JD
10
35
10
70
50
30 91
30
Sill support
(by owner)
91
30
25
30
30
30
91
E-102
E-302
Keyhole
Keyhole
100
100
13
150
Entrance
width:
JJ
150
1200
1200
Finished
floor level
A
Hoistway entrance
Entrance
width:
JJ
1200
Finished
floor level
A
150
Entrance
width:
JJ
1200
150
100
Entrance height: 2100
Entrance
width:
JJ
100
100
120
120
100
25
91
Finish
30
55
E-102
Wall
300
60
140
30
30
Sill support
(by owner)
(Min. clearance)
70
25
140 60
30
150
150
100
150
Finished
wall
(by owner)
75~113
10
20
90
Entrance width: JJ
100
E-302
Finish
Finished
wall
(by owner)
25
10
38
300
E-302
(Min. clearance)
E-102
70
E-102
300
35
70
100
150
Jamb depth:
min. 130
55
30
30
55
80
Finish
(Min. clearance)
30
100
E-302
Sill support
(by owner)
E-302
4
50
Finished wall
(by owner)
Entrance width: JJ
10
10
30
55
Wall
38
Finish
Sill support
(by owner)
E-102
55
E-102
(Min. clearance)
CO (Center Opening)
Finished
floor level
Finished
floor level
Hoistway entrance
14
Hoistway Plan
Hoistway Section
800 *1
14001030
2S
800
11001400
800 *1
14001250 *2
P10
10
700
CO
800 *1
14001250
P11
11
750
2S
800
13501400
17501400
18001530
16001750
17501590
18001830
16002050
21001460
21001600
17501810
20501800
18502700
18502050
18002980
18502900
18502200
18003280
21002050
21002050
18503100
20502200
R6
R5
Entrance
width: JJ
R4
Control
panel
Car internal
width: AA
R2
Ventilator
(by owner)
Power-receiving box
(by owner)
Power outlet (by owner)
Ceiling height
2300 (standard)
CO
Rear
Side*2
Rear*2
Rear
Side*2
Rear*2
Side
Side
Rear
Side
Overhead: OH
11001100
R3
Entrance height: HH
2100 (standard)
800
R1
1400850
2S
Access door
Width: 700
Height: 2000
800 *1
Hoistway depth: BH
1.0
1.75
CO
Car internal
depth: BB
550
P8
1.0
450
P6
Hoistway width: AH
Ventilation
grille
Machine room depth: BM
Required
Vertical Dimensions
R1
4400
4400
4630
4630
1360
1410
2200
2200
2500
2500*1*1
20
JJ
Control
panel
AA
R2
Pit depth: PD
60
60
70
70
R4
Access door
Width: 700
Height: 2000
450,
450, 550,
550, 700,
700, 750
750
550,
550, 700,
700, 750
750
Ventilator
(by owner)
Ventilation
grille
Machine room depth: BM
BB
R5
1.0
1.0
1.75
1.75
BH
R6
Reaction Loads
R5
450
11001100
1.0
1.0
14001030
1.75
8
550
1.0
11001400
1.75
1.0
10
700
14001250
1.75
11
15
750
13501400
1.0
1.75
Rear
Side
Rear
Side
Rear
Side
Rear
Side
Rear
Side
Rear
Side
Rear
Side
Side
R2
R3
R4
16
16
14
19
15
17
15
16
15
17
16
19
19
20
21
22
23
21
22
22
24
25
24
26
25
24
25
25
26
26
27
29
29
30
9
9
11
10
12
10
13
9
12
9
13
10
11
11
12
13
13
R5
R6
53
46
R6
R5
61
51
61
52
61
51
61
52
68
56
70
58
77
64
JJ
AA
R3
R4
R1
R2
Lighting
outlet
(by owner)
Powerreceiving box
(by owner)
Power outlet
(by owner)
R6
R1
21
22
20
24
22
25
23
25
22
25
22
26
26
27
28
29
29
Ventilation
grille
AH
BB
1400850
Reaction loads(kN)
BH
Counterweight
position
R3
Travel: TR
AH
Control
panel
Ventilator
(by owner)
Access door
Width: 700
Height: 2000
16
Hoistway Plan
Hoistway Section
Required
Hoistway width: AH
800 *
13501400
Side
15001740
18001720
16501800
20251720
19001800
R4
Car internal
width: AA
R6
R3
R2
1.75
825
450, 630, 825
TR <
= 30
30 < TR <
= 60
TR <
= 30
30 < TR <
= 60
TR <
= 30
30 < TR <
= 60
60 < TR <
= 70
AH
3850*1
3900*1
3900
3950
4050
4100
4150
1300*1
1350
20
2500*2
R4
1450
1500
1550
R6
Reaction Loads
450
630
825
9501300
11001400
13501400
R3
R2
R5
R1
JJ
Reaction loads(kN)
6
8
11
AA
1.0
R1
Entrance
width: JJ
Vertical Dimensions
450, 630
R5
1.0
1.0
1.75
Entrance height: HH
2100 (standard)
11001400
Ceiling height
2300 (standard)
9501300
800 *
Overhead: OH
825
800
Travel: TR
11
1.0
1.75
2S
CO
2S
CO
2S
R1
R2
R3
R4
R5
R6
31
43
48
22
32
35
23
33
35
18
26
28
61
80
92
52
68
76
P11
1.0
Hoistway depth: BH
630
BH
450
Car internal
depth: BB
P8
BB
P6
R5
17
R6
18
State-of-the-Art Factories
For the Environment. For Product Quality.
Mitsubishi Electric elevators and escalators are currently operating in approximately 90 countries around the globe. Built placing priority on
safety first, our elevators, escalators and building system products are renowned for their excellent efficiency, energy savings and comfort.
The technologies and skills cultivated at the Inazawa Works and 13 overseas manufacturing factories are utilized in a global network that
provides sales, installation and maintenance in support of maintaining and improving product quality.
As a means of contributing to the realization of a sustainable society, we consciously consider the environment in business operations,
proactively work to realize a low-carbon, recycling-based society, and promote the preservation of biodiversity.
Certification
Mitsubishi Electric de Mexico, S.A. de C.V. has acquired ISO 9001
certification from the International Organization for Standardization
based on a review of quality management.
The plant has also acquired the certification of INDUSTRIA LIMPIA,
based on the audit of corresponding program.
http://www.MitsubishiElectric.com/elevator/
2016