Sunteți pe pagina 1din 4
© DAMPGUARD Mata) Oa Made from prime virgin base Polymers to 300 microns thick Perfect membrane for providing damp profing security and dry concrete floors Will last the lifetime |. Of the structure 2 DAMPPROOFING FN) Damp proofing of ground floor slabs is perhaps the most overlooked area of the building fabric. Architects ond Engineers who would specly waterproofing systems for basement walls and floors often leave out the damp proofing of horizontal con erate slab on the ground end may unknowingly ‘ccopt sub-standard shesting's offered by suppliers to builders who are ever willing to use cheoper prod Ucts in their projects without consideration for mate Fial quality and effective functionality Damp proofing membranes have to lost the life ofthe structure and itis really not conceivable for manufacturers to use recycled grenules to manufac {ure Damp proofing membranes. This is @ prevailing obsession with third world country manufacturers who do not understand the intricate knowledge of Fising damp in relation 4o product usoge. The glabol market place is only concern with cost ond the perception of eco friendly policy without consider: tion fer product usage and reliance on quali Recycled products are generaly filled with corbon block , scettered with pin holes and pimpled ‘with Blisters on its surfaces, Manufacturers of cheap films from recycled polymers tend to conceal surface deformities with Seep coloured pigmentations such as black, grey oF deep yellow. Mune Is the best membrane availabe in the market place todey. Manufactured. from prime virgin base polyethylene Polymers, its calibreted to 300 microns In thickness. itis the perfact membrane for providing ‘domp proofing security to concrete ground floor slabs ‘ond wil last the lifetime of the sructore. DAMPGUARD SUPER 300 DPM ic manufactured to provailing stondords to meet its demonding lifelong {pplication in proventing ground moisture or vapour from penetrating concrete ground floor slobs, DAMPGUARD SUPER 300 DPM is tinted translu- cent blue to allow for easy recognition of usage by Inspectors of site. DAMPGUARD SUPER 300 DPM is supplied in o much wider width of 4 meters to reduce the need of Sealing more joints in-between sheets DAMPGUARD SUPER 300 DPM is 300 microns in thickness which insures guarded security. DAMPGUARD SUPER 300 DPM is Ultra Violet stabilised, c C Wane Ifthe ground beneath the reinforced concrete slob is saturated with water, moisture or vapour, these could be sooked up by the porous concrete slob through capillory econ [ot ikea wick soking wp oil ‘Water vopour ike all gasses, socks to difuse itself evenly through space. So, unless @ vapour borrier blocks ie path, moisture will naturally move from the high humidity area under the slab 0 the low humidity environment inside the concrete slab. Hf the vapour pressure under the concrete slob occurs at 15 Ibs per sq fit would mean that a (4) inch slab will ollow 12 gallons of water through ‘overy24 hours per 1000 eq # of concrete slab, TRE. There is no known counter treotment of anti ote which could cure rising damp when it occurs on concrete ground floor slabs. ‘The ideal solution is to demolish the affected Concrete slab, install e Dpm end recost the concrete slob in toto ‘An clternative isto install a Dpm onto the existing slob ‘ond cast onother loyer of concrete siab over the Opm. Restorative treatment could have been avoided if Dompquard hove been carefully installed the first time round: Dampavard 300 super Opm is not cost prohibitive. At just a few cent per square fit is well ‘worth its weight in salt t remains buried and will con- Tinves to work throughout the life of the building structure, ‘Most Developer, Architects and Engineers will not compromise over few cents per square foo! However they can be misled by unserupulous suppli- fers info accepting sub standord products manufac- tured from reeycled polymers ro ro ed 49 newto cnr cor eo od preemeen Ser eid earns Deas od Cet y A a Resistant Seen Surface Preparation: « Insure that the soil is properly compacted to the desired grade. © Clean concrete ground beams from soil and stains. © If the soils filed with hardcore with obvious protrusions which could rupture the Dpm film, it would be strongly suggested that a blinding layer of sand or quarry dust of sufficient thickness be spread across such hardcore ee) The applicator for termite treatment must provide protection against over spray to ground beams. Core must be token to cover ground beams from «il contamination. Whilst itis necessary to use some low cost black polythene sheets to prevent the evaporation of the chemicals, such sheeting shall be laid up t0 5 ‘mm from the vertical walls of ground beams, eon Unrell the film to desire length end width. Eneure thot of least 150 mm wide extra flm is reserved for vertical termination along ground beams or for overlapping of sheets Apply Sealflex Primer with 150 mm wide roller ‘long the poth of vertical anchorage Allow Seaflex primer to dry for 15 minutes. Unroll RONGRIP along hwo lines One should be located nearest fo the outer edge of seal, the second should be located within 150 im of seal. (refer to detail) Remove silicone release paper from Irongri Using @ flat wooden blade. such as a trowel, gradually guide Dempguard 300 SUPER to attach itsof to lrongrip @ specially formulated sensitive adhesive tape. KE 11 will be necessary to protect Dampguard 300 Super from physical Gamage. A layer of cement sond mortar of 50 mm or less ‘ill Serve to protec the membrane trom physical Somage during the installation of steel reinforce Howover, care must be token during the loying of the coment and sand protection ‘course.’ Shorp bjt such gs metal spades 0 oe shoud nl be Frenales mil be favoured, "0" “aveegee wi Distribution: ‘Malaysia, Indonesia, Brunei, Thailand, Vietnam, Cambodia, Laos, Myanmar, Philippines

S-ar putea să vă placă și