Sunteți pe pagina 1din 1

100-P6A/B 411-E11

Diesel Circulation Pump Debutanizer Reboiler (SS=Naphtha; TS=Cir. Diesel)


Suction Temp. 260oC
Operating Pressure (Suc./Disch.) 2.4/15.2kg/cm2G Operating Temp. SS (Inlet/Outlet) = (186/195 oC)
Design Pressure/Temp. 21.2kg/cm2G /285oC Operating Temp. TS (Inlet/Outlet) = 263/224 oC
Capacity (Normal/Rated) 817.6/981.2 m3/hr Operating Pressure (SS;TS) (11.9; 7.4 kg/cm2G)
Rated Power 530kW Design Pressure (SS; TS) (13.4; 24 kg/cm2G)

Current Conditions Current Conditions


Suction Temp. 268.5oC Current Temp. SS (Inlet/Outlet) = (165.6/173.8 oC)
Discharge Pressure 16.0kg/cm2G Current Temp. TS (Inlet/Outlet) = 268.5/244.8 oC
Cir. Diesel Flow to 411-E11 405m3/hr Current P = SS - TS = 10.8 14.8 = -4.0 kg/cm2G 411-V7

195/11.5
263/15.2 263/15.2 231/13.5
Startup Bypass Line
291/22 291/22
A-100 B.L. Valves A-200 B.L. Valves 263/15.0 24"

100-E16>E12>E6 10" 10" 291/22

P-2

263/2.4 411-FV111
291/5.2 263/9.0 PI
Tray 27 232/9.0
291/22 PI
12" 10" 263/22 186/11.9
18" 220/14
100-V9 263/15.2 232/13.0
4" 411-FV090
291/22 263/22
100-P6A/B 232/7.1
291/26

100-FV078 263/15.2
291/22

411-V5

LEGENDS: Operating Temperature/Pressure