Grid Connection and Substation

- Engineering Capability build Up

EMB-GCS Team

Noida India
BY: RAHUL SRIVASTAVA

Grid Connection & Substation


Contents

Scope of Activity
Substation Tendering
Engineering Tools Development
3D modeling of EHV AIS
Activities

Scope of Activity.

Substation Engineering 3 modeling of a switchyard


equipment layout, Extraction of BOQ from drawing , Costing
Sheet, SLD, DSLP Layout, Earthing layout
Engineering Calculation Earthing Design, DSLP, Short
Circuit Studies, Sag Tension of conductors, Battery Sizing,
Temperature Rise Calculation of Conductors.
Cable Engineering Preparation of Cable Philosophy as per
Protection Logic and Cable Scheduling.
Substation Tendering-
Tendering- Tenders under Completed

400kV Switchyard at Gautami Stage-II for Th System


India
220kV Switchyard at Dahej CCPP Stage-I for Th System
India
400kV Switchyard at Jegrupadu III for Th System
India
500kV Switchyard at SIAM Energy Thailand for Th Sytem
KL through EMB-KL
220kV Switchyard at Dhuvaran CCPP Stage III for Th
System India
Rehabilitation and Extension of SCADA at Bangladesh for
Bangladesh Elect. Board
400kV Switchyard at Gautami II:
II:--SLD & Top view of 3D Model

Scope of Work.
400kV AIS, 1 & Breaker Scheme, 2 Complete Dia and 1 Tie
with Line Bay
8 Nos. of SF6 CB, and All the Switchyard Equipment including
Control Control & Relay Panel
500kV Switchyard at SIAM Energy Thailand: SLD & Top View

Scope of Work.
500kV AIS, with Single Bus Scheme, and Two Power Block
2 Nos. of SF6 CB, and All the Switchyard Equipment including
Control Control & Relay Panel
220kV Switchyard at Dhuvaran III: SLD, Section & top View

Scope of Work.
220kV AIS, With Two Main and One Transfer Scheme.
7 Nos. of SF6 CB, All the Switchyard Equipment including
Control Control & Relay Panel
Rehabilitation and Extension of SCADA at Banglade

Scope of Work.
Supply and Installation of RTU, Controller and Radio Link
Communication
Laying and Termination of Control Cable between Equipment
and RTU
Conventional Contract

Substation Engineering
SLD
Tier - 1

Specification & GA Drawing & Engg. Calculation


Purchase Datasheet 2D Section Drawing Earthing Calculation
DSLP Calculation
SCF & SAG tension Calculation
Temperature Rise Calculation

Tier -

Clearance Check Structural loading


Diagram DSLP Diagram Earthing Drawing
diagram

Revised GA & Section


Drawing
Tier - 3

Protection Engineering
To Site
Erection Key Diagram

Cable Engineering To Site


Erection BOQ To Site
SMART
Substation Engineering
Contract

SLD Engg. Calculation


Earthing Calculation
DSLP Calculation
SCF & SAG Tension Calculation
Temperature Rise Calculation Tier - 1

Specification &
Purchase Datasheet 3D Modeling with all
To Customer for Approval
2D Representation of GA
Engg. Data(Elect., & Section Drawing
Structural, etc). Tier - 2

Protection Engg.

Erection BOQ To Site

Cable Engg. To Site


RISK of Conventional
Substation design

Tendering Stage
Technical BOQ Estimation
Commercial Price Back up and discount measurement
Engineering
Engineering Hours Calculation and Design
Detail Engineering
General Arrangement Engineering from 2- D
drawing
Structure Engineering Weight of civil
structures
Cable Engineering - Estimation of power and
control cables
Project Management
Client Claim End client Claim Handling process
Supplier Claim Handling Process
Project Closing Process
Reduction and Mitigation plan with Smart Substation
Engineering

Tendering Stage

Technical BOQ extraction from 3-D modeling


Commercial Price Back up and discount measurement at least from
three vendors
Engineering

Engineering Hours 3 D modeling, Calculation tools,interface of


calculation tools and 3- modeling
Detail Engineering
General Arrangement Engineering from 3-D drawing
Structure Engineering calculation of Weight of civil
structures is more accurate
Cable Engineering -easy and accurate estimation of power and
control cables through actual route
Project Management

Easy to execute at site


Deviation from BOQ during execution is minimum
Earthing Design Calculation

Gives the flexibility to


calculate the earth mat by
selecting various
parameters
Based on IEEE-80, CBIP and
IS-3043
Auto generation of the
earth mat in auto cad and
Micro station drawing
files
Auto generation of Report
in xls. Sheet
Directly give the Weight
of Material on front page
Direct Stroke Lightning Protection

What is D.S.L.P.?

Direct Stroke Lightning


Protection (D.S.L.P) for
outdoor air insulated
substation is a very
important aspect. Design
of the D.S.L.P. is
probabilistic approach
which ensures minimum
probability of lightning.

How it is achieved?

It can be achieved by
providing

Lightning Mast
Shield Wire
Combination of above
DSLP Calculation Tools

Based on IEEE-998 by
using Rolling Sphere
method, High Voltage Engg.
By Prof. Razevig
Gives the flexibility to
choose height of LM and
height of equipment to be
protected and it will
calculate the protection
area
It will Generate the
Drawing in 3-D view as
well as generate a report
in Excel file
Short Circuit Forces Calculation Tool

Calculates the short


circuit forces for
various equipment
,Busbar, Structure &
Towers
Gives user flexibility
to choose the type of
conductor based on
standard IEC-60865 and
IEEE-605
Auto Generation of the
results in specified
format
3D model of 400kV Switchyard , Gautami -II
Advantages of 3D Engineering and way ahead

High Level of accuracy


Reduced risk of Engineering miss out
Smart Engineering - linking the calculation tools to 3D
model of substation will lead to very less Engineering
hour.
Way ahead : - By next 3 months
- Validation of the Engineering tools
- Validation of 3D model
- Generation of the detail BOQ/ Erection
material from the 3D Model
Thank You