Sunteți pe pagina 1din 2

Low level outputs1 Binary outputs, relays

Number of outputs 6 (12 with Option LLO-2) Type Potential-free relay contacts, software
Setting range 0 ... 10Vpk controlled
Max. output current 1mA Number 4
Accuracy error <0.025% typ., Break capacity AC Vmax: 300VAC / Imax: 8A / Pmax: 2000VA
<0.07% guar.at 1 ... 10Vpk Break capacity DC Vmax: 300VDC / Imax: 8A / Pmax: 50W
Resolution 250V Binary outputs, transistor
Distortion (THD+N)2 <0.015% typ., <0.05% guar. Type Open collector transistor outputs
Unconventional CT/VT simulation linear, Rogowski (transient and sinewave) Number 4
Overload indication yes Update rate 10kHz
Isolation SELV Imax 5mA
Usability completely independent from internal Connection 16 pin combination socket (rear side)
amplifier outputs DC voltage measuring input (If option ELT-1 is equipped3)
Connection 16 pin combination socket (rear side) Measuring range 0 ... 10V
Auxiliary DC supply Accuracy Error <0.003% rg.5 typ.,
Voltage ranges 0 ... 264VDC, 0.2A / 0 ... 132VDC, <0.02% rg. guar.
0.4A / 0 ... 66VDC, 0.8A Input impedance 1 M
Power max. 50W DC current measuring input (If option ELT-1 is equipped3)
Accuracy error <2% typ., <5% guar Measuring range 0 ... 1mA, 0 ... 20mA
Binary inputs Accuracy Error <0.003% rg.5 typ., <0.02% rg. guar.
Number 10 Input impedance 15
Trigger criteria Toggling of potential-free contacts or DC Analog AC+DC measuring inputs (If option ELT-1 is equipped3,4)
voltage compared to threshold voltage
Type AC + DC analog voltage inputs (current
Input characteristics 0 ... 300VDC threshold or potential-free
measurement with external current clamps
If equipped with ELT-13: 0 ... 600VDC
or shunt resistors)
threshold or potential-free
Number 10
Ranges 20V / 300V
Nominal input ranges (RMS values) 100mV, 1V, 10V, 100V, 600V
If equipped with ELT-13: 100mV / 1V / 10V/
100V / 600V Amplitude accuracy Error <0.06% typ., <0.15% guar.
Resolution of threshold 50mV (0 ... 20V), 500mV (20V ... 300V) Bandwidth DC ... 10kHz
ELT-13: 2 mV, 20mV, 200mV, 2V, 20V Sampling frequency 28.44kHz, 9.48kHz, 3.16kHz
in ranges Input impedance 500k // 50pF
Sample rate 10kHz (resolution 100s) Transient input buffer at 28kHz 3.5 s for 10 input channels
Time stamping accuracy 0.00015% of rd.5 70s 35 s for 1 input channel
Max. measuring time infinite Transient input buffer at 3kHz 31 s for 10 input channels
Debounce / Deglitch time 0 ... 25ms / 0 ... 25ms 5 min. for 1 input channel
Transient trigger Threshold voltage, power quality trigger:
Counting function <3kHz at pulse width >150s
sag, swell, harmonic, frequency, frequency
Galvanic isolation 5 galvanically isolated groups (2+2+2+2+2)
change, notch
Max. input voltage CATIV / 150V, CATIII / 300V, transient
Measurement functions I (AC + DC),V (AC + DC), phase, frequency,
immunity 2 kV
power, harmonics, transient-, event- and
If equipped with ELT-13: CATIV / 150V,
trend recording
CATIII / 300V, CATII / 600V (850Vpk)
Input overload indication Yes
Counter inputs 100kHz
Input protection Yes
Number 2
Max. input voltage CATIV / 150V, CATIII / 300V, CATII / 600V
Max. counting frequency 100kHz (850Vpk)
Pulse width >3s Galvanic isolation 5 groups (2+2+2+2+2)
Threshold voltage 6V Time synchronization
Voltage hysteresis 2V Timing accuracy (voltage/current)
Max. input voltage 30V IRIG-B synchronization with CMIRIG-B Error <1/5s typ., <5/20s guar.
Isolation SELV GPS synchronization with CMGPS588 Error <1/5s typ., <5/20s guar.
Connection 16 pin combination socket (rear side) To external voltage Reference signal on binary input 10:
Trigger on overload 15 ... 70Hz
Precision Time Protocol (PTP) IEEE1588-2008
Supported generators Current generators
IEEEC37.238-2011 (Power Profile)
Timer accuracy error <1ms
With the unique PermaSync functionality, analog and Sampled Values outputs stay
permanently in sync with the internal CMC time reference.
When a CMC is time-synchronized (IRIG-B, GPS, or PTP), the output quantities are
continuously synchronized to the external time source.
With CMIRIG-B it is also possible to transmit the internal PPS signal of the CMC to the
device under test (e.g. PMUs or IEDs stimulated with a synchronized Sampled Values
data stream).
1
For directly testing relays with low level inputs by simulating signals from non
conventional CTs and VTs with low level interfaces and for controlling external
amplifier units
2
THD+N: Values at 50/60Hz, 20kHz measurement bandwidth, nominal value,
and nominal load
3
The ELT-1 hardware option turns the ten binary inputs into multifunctional
analog AC and DC voltage measuring inputs and adds two DC measuring inputs
(0 10V / 0 20mA) for transducer testing
4
Up to three inputs can be used for measuring RMS values, frequency, and
phase angle without the EnerLyzer software license. Full functionality requires
EnerLyzer software license
5
rd. = reading, rg. = range
Technical Data CMC356 (continued)
IEC61850 GOOSE1 Miscellaneous
Simulation Mapping of binary outputs to data attributes in Weight 16.8kg (37.0lbs)
published GOOSE messages. Dimensions 450 x 145 x 390mm (17.7 x 5.7 x 15.4in)
Number of virtual binary outputs: 360 (W x H x D, without handle)
Number of GOOSEs to be published: 128 PCconnection Two PoE4 Ethernet ports:
Subscription Mapping of data attributes from subscribed GOOSE 10/100/1000 Base-TX
messages to binary inputs. IEEE802.3af compliant
Number of virtual binary inputs: 360 Port capability limited to one Class1 (3.84W) and
Number of GOOSEs to be subscribed: 128 one Class2 (6.49W) powered device
Performance Type 1A; Class P2/3 (IEC61850-5). USB port:
Processing time (application to network or vice versa): USB 2.0 High Speed up to 480 Mbit/s
<1ms USB 1.1-compatible
VLAN support Selectable priority and VLAN-ID Signal indication (LED) >42V for voltage and current outputs and AUX DC
IEC61850 Sampled Values (Publishing)1 Connection to ground (earth) 4mm (0.16in) banana socket (rear side)
Specification According to the Implementation Guideline for Hardware diagnostics Self diagnostics upon each start-up
Digital Interface to Instrument Transformers Using Galvanically separated groups The following groups are galvanically separated from
IEC61850-9-2 of the UCA International Users Group each other: mains, voltage amplifier output, current
Sampling Rate 80 samples per cycle for nominal frequencies of 50Hz amplifier group A/B, auxiliary DC supply, binary/
and 60Hz. analog input
Synchronization Synchronization attribute (smpSynch) is set when the Protection All current and voltage outputs are fully overload and
CMC is in synchronized operation mode. short circuit proof and protected against external
Sample count (smpCnt) zero is aligned with top of the high-voltage transient signals and over temperature
second. Certifications
Accuracy data see above
VLAN support Selectable priority and VLAN-ID
Max. number of SV streams 2 (with option LLO-2: 3 SV streams)
Power supply
Nominal input voltage2 100240VAC, 1-phase
Permissible input voltage 85 ... 264VAC
Nominal frequency 50/60Hz
Developed and manufactured under an ISO9001
Permissible frequency range 45 ... 65Hz
registered system
Rated current 12A at 115V / 10A at 230V
Connection Standard AC socket (IEC60320)
Environmental conditions
Operation temperature3 0 ... +50C (+32 ... +122F) Ordering Information
Storage temperature -25 ... +70C (-13 ... +158F)
CMC356 with Test Universe software
Humidity range Relative humidity 5 ... 95%, non-condensing
VE002801 CMC356 Basic
Vibration IEC60068-2-6 (20 m/s at 10 ... 150Hz)
2

Shock IEC60068-2-27 (15g/11ms half-sine) VE002802 CMC356 Protection


Safety standards, electromagnetic compatibility VE002803 CMC356 Advanced Protection
EMC The product adheres to the electromagnetic compat- VE002825 CMC356 Recloser
ibility (EMC) Directive 2004/108/EC (CE conform).
International IEC61326-1; IEC61000-6-4; IEC61000-3-2/3
USA FCC Subpart B of Part 15 ClassA
CMC356 with CMControl (without Test Universe software)
Safety The product adheres to the low voltage Directive VE002820 CMC356 with CMControlP
2006/95/EC (CE conform). VE002824 CMC356 with CMControlR
International / USA IEC61010-1 / UL61010-1
VE002826 CMC356 with CMControlP App activation key
Canada CAN/CSA-C22.2 No61010-1-04
VE002827 CMC356 with CMControlR App activation key
The CMControl can also be ordered as add-on together with a
CMC356 with Test Universe software or as a later upgrade.

CMC356 hardware options


VEHO2801 Option ELT-1 if ordered with a new unit
VEHO2802 Option ELT-1 if ordered as an upgrade
VEHO2803 Option LLO-2 if ordered with a new unit
VEHO2804 Option LLO-2 if ordered as an upgrade

1
The GOOSE and Sampled Values functionality require software licences for the
respective configuration modules
2
For line input voltages below 230V, a derating of the simultaneously available
sum output power of the voltage/current amplifiers and the AuxDC will occur
All other technical specifications (e.g. the maximum output power of a single
amplifier) are not affected
3
For an operational temperature above +30C (+86F) a duty cycle of down to
50% may apply
4
PoE = Power over Ethernet