Sunteți pe pagina 1din 11

Expansion joint legend

Plant : Nyumba Ya Akiba-Cement Plant 3000 TPD


Department : 421, Cyclone preheater
Contract : 1345327_900
Approved date : 16-Sep-14
Created by : EKA
Approved by : VSS

Doc. no.: 50064436-2.0


Expansion joint legend
Doc. no.: 50064436-2.0
Plant: Nyumba Ya Akiba-Cement Plant 3000 TPD
Department: 421 Cyclone preheater

Table of contents Page

1 Table .......................................................................................................... 3
2 Duct expansion joints .................................................................................... 4
3 Chute expansion joints................................................................................... 5
4 Dedusting pipe expansion joints ...................................................................... 6
5 Lined expansion joint ..................................................................................... 7
6 Reinforced expansion joints ............................................................................ 8
7 Scissor expansion joints ................................................................................. 9
8 Circular flange ............................................................................................. 10
9 Rectangular / square flange ........................................................................... 11

The next pages in the legend specify:

Item no.: Item numbers refer to the reference numbers from the general
arrangement drawings and general arrangement legends.
Duct, chute, dedusting pipe: Refers to type of the expansion joint required.
Dimensions: Dimensions as given by plant layout.
GA plan no.: General arrangement plan number, where the given expansion
joint can be found.
Temp [C]: Temperature value from the flow sheet.
Pressure [kPa]: Pressure value from the flow sheet.
Axial movement [mm]: Calculated axial movement given in mm.
Lateral movement [mm]: Calculated lateral movement given in mm.
H erection measure [mm]: Calculated height of expansion joint.
Drawing model: Refer to model type of the expansion joint (see appendices).
Page no.: Refer to which page number to find the drawing for the
selected drawing model.
Remarks: If special conditions or comments are required for the
expansion joint.

Flanges: Flanges are only standard for explosion shock resistant


expansion joints, and for expansion joints lined with refractory
lining.
All other expansion joints will be supplied without flanges.
Expansion joints will only be supplied with flanges if required
by contract.

Erector's note:
Normal erection operations include the correction of minor misfits by moderate amounts of
straightening, shimming, reaming, chipping, cutting or grinding and the drawing of elements
into line through the use of drift pins. Misfits which cannot be corrected by the foregoing means
or which require major changes in equipment configuration are to be reported immediately to
the supplier by the erector, to enable the supplier either to correct the misfit or to approve the
most efficient and economic method of correction to be implemented.

The information transmitted by this document is the proprietary and confidential property of FLSmidth 2/11
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.
Expansion joint legend
Doc. no.: 50064436-2.0
Plant: Nyumba Ya Akiba-Cement Plant 3000 TPD
Department: 421 Cyclone preheater

1 Table
Duct H
chute Dimension GA Axial Lateral Erection
dedusting [mm] plan Temp Press exp. exp. measure Drawing
Item no. pipe AxB/A no. [C] [kPa] [mm] [mm] [mm] model Remarks
Lining thickness 250mm
46 TAD 2360 20 150 2 15 25 700 Lined 2
See flange 1 (Pg.10)

Insulation bag,
Offset by 45 mm,
59-1 Duct 2500x2500 13, 14, 450 7.5 60 90 1000 Duct 2
see sketch 1 (pg. 4)

Scissor 1,
59-2 Duct 3000 14, 17 450 7.5 500 10 2280 vertical duct Vertical duct only
only

59-3 Duct 3550x900 14, 17 450 7.5 105 10 650 Duct 1

59-4 Duct 3550x900 14, 17 450 7.5 105 10 650 Duct 1

59-5 Duct 2500x2000 18 300 1 45 10 450 Duct 1

63-1 Chute 800x595 15 120 0 90 10 410 Chute 2 Compressed by 90 mm

63-2 Chute 400 17 120 0 10 30 550 Chute 2

63-3 Chute 800x500 16 120 0 140 10 560 Chute 2 Compressed by 140 mm

63-4 Chute 900x355 16, 17 120 0 45 10 350 Chute 1

63-5 Chute 630 16, 18 120 0 15 25 350 Chute 1

63-6 Chute 630 16, 18 120 0 10 10 350 Chute 1

63-7 Chute 400 14 450 0 70 10 500 Chute 2

The information transmitted by this document is the proprietary and confidential property of FLSmidth 3/11
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.
Expansion joint legend
Doc. no.: 50064436-2.0
Plant: Nyumba Ya Akiba-Cement Plant 3000 TPD
Department: 421 Cyclone preheater

2 Duct expansion joints


Model: Duct 1 Model: Duct 2
Rectangular or circular. Rectangular or circular, offset.

Model: Duct 3 Model: Duct 4


Rectangular or circular with flanges. Rectangular or circular with flanges, offset.

aa
Model: Sketch 1

Flow direction is shown with an arrow at position 1. X mm to be offset from centre line.

The information transmitted by this document is the proprietary and confidential property of FLSmidth 4/11
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.
Expansion joint legend
Doc. no.: 50064436-2.0
Plant: Nyumba Ya Akiba-Cement Plant 3000 TPD
Department: 421 Cyclone preheater

3 Chute expansion joints


Model: Chute 1 Model: Chute 2
Chute type 1. Rectangular or circular. Chute type 2. Rectangular or circular.

Model: Chute 3 Model: Chute 4


Chute type 2. Rectangular or circular, offset. Detachable chute.

B = A (2x lateral movement) - 10

Model: Sketch S

Flow direction is shown with an arrow at position 1. X mm to be offset from centre line.

The information transmitted by this document is the proprietary and confidential property of FLSmidth 5/11
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.
Expansion joint legend
Doc. no.: 50064436-2.0
Plant: Nyumba Ya Akiba-Cement Plant 3000 TPD
Department: 421 Cyclone preheater

4 Dedusting pipe expansion joints


Model: Dedusting 1 Model: Dedusting 2
Dedusting pipe, rectangular. Dedusting pipe, circular.

A1 = A (2x lateral movement) - 10 B = A (2x lateral movement) - 10


B1 = B (2x lateral movement) - 10

Flow direction is shown with an arrow at position 1.

The information transmitted by this document is the proprietary and confidential property of FLSmidth 6/11
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.
Expansion joint legend
Doc. no.: 50064436-2.0
Plant: Nyumba Ya Akiba-Cement Plant 3000 TPD
Department: 421 Cyclone preheater

5 Lined expansion joint


Model: Lined 1 Model: Lined 2
Lined with 114 brick lining. Lined with 214/250/254/264 brick lining.

Model: Lined 3 Model: Lined 4


Lined with Densit. Lined with Densulate.

Flow direction is shown with an arrow at position 1.

The information transmitted by this document is the proprietary and confidential property of FLSmidth 7/11
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.
Expansion joint legend
Doc. no.: 50064436-2.0
Plant: Nyumba Ya Akiba-Cement Plant 3000 TPD
Department: 421 Cyclone preheater

6 Reinforced expansion joints


Model: Reinforced 1 Model: Reinforced 2
Duct, reinforced, rectangular or circular. Chute, reinforced, rectangular or circular.

Model: Reinforced 3 Model: Reinforced 4


Dedusting, reinforced. Chute, circular, detachable.

B = A (2x lateral movement) - 10 B = A (2x lateral movement) - 10

Flow direction is shown with an arrow at position 1.

The information transmitted by this document is the proprietary and confidential property of FLSmidth 8/11
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.
Expansion joint legend
Doc. no.: 50064436-2.0
Plant: Nyumba Ya Akiba-Cement Plant 3000 TPD
Department: 421 Cyclone preheater

7 Scissor expansion joints


Model: Scissor 1 Model: Scissor 2
Scissor. Duct expansion joint. Scissor. Chute expansion joint.

Flow direction is shown with an arrow at position 1.

The information transmitted by this document is the proprietary and confidential property of FLSmidth 9/11
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.
Expansion joint legend
Doc. no.: 50064436-2.0
Plant: Nyumba Ya Akiba-Cement Plant 3000 TPD
Department: 421 Cyclone preheater

8 Circular flange
Item no. D1 t D bxt k d2 no. Remarks
Flange 1 2480 12 1968 2430 24 48 (46) TAD &
See ME drawing for sketch
Flange 2
Flange 3
Flange 4
Flange 5
Flange 6
Flange 7
Flange 8
Flange 9
Flange 10
Flange 11
Flange 12
Flange 13
Flange 14
Flange 15
Flange 16
Flange 17
Flange 18
Flange 19

Circular flange. Special flange 1.

Special flange 2. Special flange 3.

The information transmitted by this document is the proprietary and confidential property of FLSmidth 10/11
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.
Expansion joint legend
Doc. no.: 50064436-2.0
Plant: Nyumba Ya Akiba-Cement Plant 3000 TPD
Department: 421 Cyclone preheater

9 Rectangular / square flange


Item no. axb bxt k1 e k2 f d2 Remarks
Flange 1
Flange 2
Flange 3
Flange 4
Flange 5
Flange 6
Flange 7
Flange 8
Flange 9
Flange 10
Flange 11
Flange 12
Flange 13
Flange 14
Flange 15
Flange 16
Flange 17
Flange 18
Flange 19

Rectangular/square flange. Special flange 1.

Special flange 2. Special flange 3.

---o0o---

The information transmitted by this document is the proprietary and confidential property of FLSmidth 11/11
and may not be duplicated, disclosed or utilized without written consent from FLSmidth.

S-ar putea să vă placă și