Proportional Electro-

Hydraulic Directional and


Flow Control Valves
25 MPa
Max. Operating Pressure

Proportional Electro-Hydraulic Directional and Flow Control Valves


These valves are double-deck directional and flow control valves employing
as their pilot the electro-hydraulic proportional reducing valves with two
proportional solenoids.
The flow rate can be controlled by changing an input current to the solenoids
and the direction of the flow can be controlled by providing the current to
either solenoid of the two.
By combining the valves with the power amplifiers specially designed for the
valves, the speed control and directional control can be done with a single
valve, which eventually makes the hydraulic circuits sim ple and contributes
the cost of the hydraulic systems.

Specifications
3UJKR4U EDFHG-04 EDFHG-06
Description
Max Operating Pressure MPa 25
1
Rated Flow L/min  280
2
Pilot Pressure MPa d
at Normal 1 2
Pilot Flow L/min
at Transition 4 6
3
Max. Tank Line Back Pressure MPa 21
Max. Drain Line Back Pressure MPa 3.0
Rated Current mA 980 900
Coil Resistance 10
Hysteresis 5% or less
Repeatability 1% or less
Approx. Mass kg 12 15
1 : Rated flow : At valve pressure drop 1.0 MPa.
2 : Take care to keep the difference between the pilot pressure and drain port back
pressure consistently greater than 1.5 MPa.
3 : To obtain staple performance, keep the drain port back p ressure low and minimize
its fluctuations.

Graphic Symbols Model Number Designation


External Pilot Type
External Drain Type EDFHG - 04 - 140 - 3C2 - XY - E - 30T
A B Series No. Design Number
Valve Size Pilot Connection
P T 0406 None : Internal Pilot
Y X E : External Pilot
Internal Pilot Type Rated Flow
External Drain Type 04 : 140 L/min Direction of Flow :
A B 06 : 280 L/min XY : Meter-in & Meter-out
Spool Type
P T
3C2 3C40
Y

Applicable Power Amplifiers Note


For stable performance, it is recommended To ensure stable control , bleed the air from solenoid completely and fill the iron
that Yuken's applicable power amplifiers be core with oil. For this purpose, it is recommended to pr ovide the drain line with
used (AMN-W-10T) a check valve having a cracking pressure about 0.04 MPa.
In the event of an electric fault emergency, a manual shift can be made by screwing
in the manual adjustment screw. Take care, however, that this manual shift has no
flow adjusting function.

Mounting Bolts. (Attachment)


M
( 1.2 ~ 1.5 )
25 MPa
Max. Operating Pressure

Proportional Electro-Hydraulic Directional and Flow Control Valves


Sub-plates
Model No. Sub-plate Model No. Thread Size Sub-plate are available, specify the sub-plate model no from the table above,
when sub-plates are used, the mounting surface should have a good machined
DHGM-04-20 1/2
EDFHG-04 finish .
DHGM-04X-20 3/4
Sub-plates are those for solenoid controlled pilot operated directional valves,
DHGM-06-50 3/4 for dimensions, refer to DSHG series sub-plate dimensions.
EDFHG-06
DHGM-06X-50 1

Input current vs. Flow Viscosity: 30mm /s


Valve Pressure Difference : PA (B), B (A)T 1MPa EDFHG-06
320
EDFHG-04
160 A B 280 A B
A B 140 A B 240
120 P T P T
200
P T 100 P T
160
Flow 80 Flow
Rate 60 120 Rate
L/min 40 80 L/min
20 40

800 400 0 400 800 800 400 0 400 800


1000 600 200 200 600 1000 1000 600 200 200 600 1000
Input Current (mA) Input Current (mA)

Valve Pressure Drop vs. Flow Viscosity: 30mm 2/s


400 900 mA A B
EDFHG-06
EDFHG-04 280 A B 800 mA
Flow Rate 300 P T
240 900 mA L/min
Flow Rate P T
800 mA
L/min 200
160
Valve Pressure Diff.
Valve Pressure Diff. 100
80 MPa 700 mA
MPa 25.0
25.0 700 mA 24.0 16.0 8.0 600 mA
24.0 16.0 8.0
600 mA 0 8.0 16.0 24.0
700 mA 0 8.0 16.0 24.0 25
25 700 mA Valve Pressure Diff. MPa
Valve Pressure Diff. MPa 100
80

200
160
800 mA
A B 900 mA 300 Flow Rate
A B 800 mA
240 Flow Rate L/min
P T 280 L/min 900 mA
P T 400

Step Response Viscosity: 30mm2/s


These characteristics have been obtained by measuring on each valve.
Therefore, they may according to the hydraulic circuit to be u sed EDFHG-06
400
EDFHG-04
175 350
150 300
125 250
100 0.1s 200 0.1s
75 150
50 100

0
Time Time
25 MPa
Max. Operating Pressure

Proportional Electro-Hydraulic Directional and Flow Control Valves

EDFHG-04-- ( For External Pilt Models Only ) Mounting Surface :


Tank Port "T" Pressure Port "P" Pilot Pressure Port "X" Comfort to ISO 4401-AD-07-4-A-80
For valve mounting surface dimensions ,
Dia. 11 Through see the dimensional drawings of
Dia. 17.5 Spotface sub-plates DSHG-04
4 Places

SOL a SOL b

Air Vent (Both Ends)


3 Hex. Soc.

Cylinder Port "A" Pilot Drain Port "Y"


Dia. 7 Through ; Dia. 11 Spotface Cylinder Port "B"
2 Places
Cable Departure ( Outside Dia. 8-10 ) Connector

Use for changing


the air vent direction Manual Adj. Screw
22 Hex. Soc. 3 Hex. Soc
( Both Ends ) ( Both Ends )
SOL a SOL b

INC

Mounting surface ( O-rings furnished ) 3 Dia. Two locating Pins

EDFHG-06-- Mounting Surface :


Tank Port "T" Pressure Port "P"
Comfort to ISO 4401-AE-08-4-A-80
For valve mounting surface dimensions ,
see the dimensional drawings of
Pilot Drain Port "Y"
Air Vent ( Both Ends )
sub-plates DSHG-06
3 Hex. Soc.

SOL a SOL b

Dia. 13 Through
( For External Pilt Models Only ) Dia. 20 Spotface
Pilot Pressure Port "X" 6 Places

Cylinder Port "A" Cylinder Port "B"


Cable Departure ( Outside Dia. 8-10 ) Connector

Use for changing


the air vent direction
22 Hex. Soc. Manual Adj. Screw
( Both Ends ) 3 Hex. Soc
SOL a SOL b
( Both Ends )

INC

Mounting surface ( O-rings furnished ) 6 Dia. Two locating Pins


YUKEN EUROPE Ltd
51 Spindus Road, Speke Hall Industrial Estate
Liverpool, UK, L24 1YA
Tel: +44 (0)151 486 4696
Fax: +44 (0)151 486 3537

25 MPa
Max. Operating Pressure
Proportional Electro-Hydraulic Directional and Flow Control Valves
EDFHG-04- & EDFHG-06- Wiring Diagram
Cable Departure
Cable Applicable:
outside Dia. 8-10mm
Conductor Area ( 0.75~1.5mm 2 ) Terminal No Name of Terminal

1 +24V
R
Power Supply
SOL a SOL b
2 0V
3 Ground G
SOL a SOL b
Solenoid Solenoid
4 +12V
Internal Power Supply
5 -12V
6
9 10 11 12 7 IN
SOLa SOLb
Input Signal
R
8 COM
SOLa SOLb

9
Output to Valve Solenoid
SPANa SPANb DELAY
SOL a
10
POWER
11
MODEL AMN-W-10T Output to Valve Solenoid SOL b
MFG No. 12
24V 0V G +12V -12V IN COM
1 2 3 4 5 6 7 8

Attention : Wiring of Input signal and output to valve solenoid :


1. Please use the isolation wire with input signal and output to valve solenoid
and the ground wire must be connected to the ground, so it can reduce the
Ground
Input Signal
unstable situation influenced form the mixed signals.
DC24V individual power supply 2. To prevent interfering, please do not put the wiring of input signal and
not to share with solenoid valve
output to valve solenoid through the main power supply

Power Amplifiers
These power amplifiers are used to drive the shockless type proportional and flow control valves.

Ratings Terminal Board Model Number Designation


Model No. Terminal AMN -W - 10T
AMN-W-10T Name
Description Number
Type of Function DC Input Type Series Type of Design
1 +24V Number Function. Number
Max. Output Current 1.3 A ( 10 Solenoid ) Power supply
2 0V
W:
-10 V DC : SOL a 3 Ground G AMN 10T
Max. Iuput Voltage DC Input Type
+10 V DC : SOL b 4 Internal Power +12V
5 Supply -12V
Input Impedance 10 k
1.3 A / -5 V : SOL a
6 Applicable to Valve
Max. Gain 7 IN
Input Signal Name of Valve Model Number
1.3 A / +5 V : SOL b 8 COM
Dither Variable 9 Output to Proportional
SOL a EDFHG-04-
10 Valve Solenoid Electro-Hydraulic
Delay Time Adj. Range 0.1 ~ 3 s
11 Output to Directional and
Temperature Drift 0.2 mA / SOL b Flow Control
12 Valve Solenoid EDFHG-06-
Power Supply DC24V ( DC 20 ~ 30 V ) Valves
Power Input 25 W
Ambient Temperature 0 ~ 50
Ambient Humidity 90 % RH or less
Approx. Mass 0.2 kg

AMN-W-10T Terminal Board


DELAY Adjustment xample Diagram
SOL b
Manually Operated
3.5 Dia. SOL a,b DELAY Setting Adjuster MIN a
DELAY
2 Places Indicator lamp 0 MC-02 SPAN a 9 SOL a
DELAY 4
9 10 11 12
DELAY +12V
SOLa SOLb
SPAN a,b SOL a 10
7
R Span adjuster DELAY
5 11 SOL b
SOLa SOLb -12V
DELAY
+V 8
SPANa SPANb DELAY Delay Adjuster SPAN b 12
DELAY
0 2k MIN b
G DITHER
-V
24V 0V
POWER 1 2
MIN a,b
MODEL AMN-W-10T Zero Adjuster
MFG No.

24V 0V G +12V -12V IN COM


Indicator lamp
1 2 3 4 5 6 7 8

Terminal Board