Sunteți pe pagina 1din 4

MULTIFUNCTION POWER PROTECTION RELAYS

CONTROL & RELAY PANEL


SCADA SYSTEM FOR SUBSTATION AUTOMATION
SMART GRID SOLUTIONS

ASHIDA Numerical
OC/EF Protection Relay
ADR 241 B

ON
C P%100 x 0.10 HBPC
1 E%005 x 0.01 H0.5
PKP

ANSI IES PROTECTION FUNCTION


FAULT
50 I>> INSTANTANEOUS OVER CURRENT
50N IE INSTANTANEOUS EARTH FAULT
TRIP 50, 51 I<t, Ip TIME OVER CURRENT (PHASE) series
50N, 51N I E>t, IEp IME OVER CURRENT (EARTH)

MODE +/

TEST BYPASS
RESET

FEEDER PROTECTION
TRANSFORMER PROTECTION
RMU PROTECTION
MOTOR PROTECTION
TRACTION PROTECTION
ASHIDA Numerical
OC/EF Protection Relay
PROT.H
ERR

FAULT
PKP
L5

L6
Ashida Digital
3OC/1EF IDMT Relay
ADR241B_V2_R2 V02.01
Protection
Relays
DT
ADR 241 B REC L7
Unit ID = 0001
LOCK TRIP
BF CLOSE
ON
C P%100 x 0.10 HBPC
1 E%005 x 0.01 H0.5
PKP

ANSI IES PROTECTION FUNCTION


FAULT
50 I>> INSTANTANEOUS OVER CURRENT
50N IE INSTANTANEOUS EARTH FAULT
TRIP 50, 51 I<t, Ip TIME OVER CURRENT (PHASE) series
50N, 51N I E>t, IEp IME OVER CURRENT (EARTH)

MODE +/

TEST BYPASS
RESET

de

1C
1A
1B
5B
1C
Co

24
24
24
24
21
SI

R
R
R
R
R
Feeder Protection Relay

AN

AD
AD
AD
AD
AD
IDMT/ DT Over current Protection 51 1 1 3 3 1

de

4A
4B
Co
Instant /DT Over current Protection 50 1 1 1 1 1

24
24
SI

R
R
Neutral/Ground IDMT/DT Over

AN

AD
AD
current Protection 51N 1 1 2 2 Motor Protection Relay
Neutral/Ground Instant/DT Over IDMT/ DT Over current Protection 51 2 2
current Protection (stages) 50N 1 1 1 1 Instant /DT Over current Protection 50 1 1
Negative Sequence Over current 46 Neutral/Ground IDMT/DT Over
CB Failure 50BF current Protection (Stages) 51N 2 2
Under Voltage / Over Voltage 27/59 Instant /DT Neutral/Ground
Over current Protection 50N 1 1
Directional phase over current/ Neutral 67/67N
Negative Sequence Over current 46
Autorecloser / 4 Nos of Shots 79
Phase Reversal Protection 46R
Cold load pickup CLP
Prolonged start (Excessive long start) 48
CONTROL FUNCTION
Locked Rotor during Starting 51S(51MS)
Trip circuit supervision
Stall Rotor/Locked Rotor Protection 51LR
Self-monitoring(diagonstic)
Motor Re-Acceleration authorization 27LV
Disturbance records:
Excess No of starts (No. of start limitation) 66
Faults Records
Anti-backspin ABS
Event Records/ Event logging
Thermal Overload Protection 49
COMMUNICATION
CB Failure 50BF
Local HMI
Under-Voltage/ Over-Voltage/ 27/
Comm. Port Residual overvoltage 59/59N
MODBUS / IEC-103 Protocols Directional Power Protection 32
IEC61850 available Reverse Power Protection 32R
Programmable LEDs Out of step/ Power factor Protection 55
Non Communicable Relay: ADR 141A / ADR 131A / ADR141C Under / Over frequency Protection 81U/81O
3 Ph Voltage Check
l

)
nta

Latching output contacts 86


ct

Self Powered
t
Ou

pa
l
ica

omal
izo

RMU Protection Relays CONTROL FUNCTION


(Crtic
aw
rt

ADR 241S
Ho
Ve

Dr
Ve

Trip circuit supervision 74TC


Over Current IDMT/DMT Protection Self-monitoring
Horizontal
Earth Fault IDMT/DMT Protection Emergency restart 66/86
In Rush Current Blocking Disturbance records
Cold Load Pick Up Faults Records / Event Records
Latching type relay for Ann. Communication Port
Non Latching relay for Trip Digital Input synchronization
Contact Protection Healthy IEC-103 Protocols
Internal Battery Local HMI
Draw Out
External Battery
Self Monitoring (Diagnostic)
Dual Power
Up to 5 Fault Memory
Trip CIRCUIT Supervisory Relay
Local HMI ATSR31A
Mechanical Flag
Control Supply : 24 / 30 / 110 / 220 VDC
Serial Communication Port RS 232 RS 232 USB USB
Aux. annunciation supply : 24 / 30 / 110 / 220VDC.
Vertical
Parallel Communication Port (RS 485) Trip coll DC resistance : To be less then 500 Ohms
Flush Mounting Operating Time : 1.0 sec
Control & aux. supply : Can be made parallel
Bracket Mounting
Supervision : Pre Closing & Post Closing
Draw Out Cabinet
Self Powered Design Suitable for RMU Automation Note: Non Communicable Relays are also available.
For more details please visit www.ashidaelectronics.com
Vertical (Compact)
PROT.H
ERR L5

FAULT
L6
Ashida Digital
PKP
3OC/1EF IDMT Relay
DT ADR241B_V2_R2 V02.01
L7
REC
Unit ID = 0001
LOCK TRIP
BF CLOSE

3 phase Numerical
Distance Protection Relay
ADR 239A
Auxiliary Relay
Independent Polygonal / Mho Model Function
ASHIDA Numerical 3 Phase Transformer
Characteristics for Phase to Ground &
Protection Relay

Ph-Ph fault AVAJH 13 High Speed Master Trip Relay (1 Element)


AVAJH 23 High Speed Master Trip Relay (2 Element)
Five Independent zone of Protection
AVAJH 33 High Speed Master Trip Relay (3 Element)
Power Swing Detection
AVAJHM 23 High Speed Tripping Relay
de Load Encroachment (2 Element In Series)

3B
3A
Settable SOTF and Auto Recloser AVAJHM 33 High Speed Tripping Relay
Co

23
(3 Element In Series)
23
Transformer Differential Backup Over/ Earth fault protection
SI

R
R

AVA 11 Voltage Operated Aux. Relay (1 Element)


(DIR / NON DIR)
AD
AN

AD

Protection Relay AVA 21 Voltage Operated Aux. Relay (2 Element)


Under/over voltage protection
AVA 33 Voltage Operated Aux. Relay (3 Element)
IDMT/ DT Over current Protection (stages) 51 - 2 C B failure
AVA 21D DC Failure Alarm Relay
Instant/DT Over current Protection(stages) 50 - 1 Disturbance Recorder Note : For other models Please refer detail technical catalogues
Neutral/Ground IDMT/DT Over IEC 60870-103 / IEC 103 Protocol Specification
current Protection 51N - 2 Trip circuit supervision Operation : 50 to 120% of rating for AVAJH
Limits 70 to 110% for AVA
Neutral/Ground Instant/DT 1000 nos. Event Records Operational : 10 - 15 mS at normal rated voltage
Over current Protection (stages) 50N - 1 Fuse Fail Detection Time for AVAJH, 20 - 25 mS for AVA
Coil Rating : 24V / 30V / 110V / 220V or AC
Restricted Earth Fault 64N/87N Frequency 50 / 60 Hz Burden : 30/24V, 3VA, 110V, 2VA, 220V, 4VA
Negative Sequence Over current 46 Temperature Range -10 to 55C Operational : Mechanical Flag (Red for
Indicator Alarm, white for Normal)
CB Failure 50BF Contacts : 4 pair of Hand Reset
Conforms : IS:3231 fully for all requirements
UnderVoltage/Over Voltage 27/59 Contact Rating
Transformer Differential 87T Make & Carry Make & Carry
PROT.H
Break
Continuous For 3.0 ssc.
ERR L5

Over Excitation 24 FAULT


PKP L6
Ashida Digital
3OC/1EF IDMT Relay
ADR241B_V2_R2 V02.01
AC 1250 VA with 7500 VA with 1250 VA with
DT
L7
REC
Unit ID = 0001
LOCK TRIP

maxima of maxima of maxima of


BF CLOSE

Self-monitoring (diagnostic) 5 A & 660 V. 30 A & 660 V. 5 A & 660V.


Disturbance records DC 1250 VA with 7500 VA with 100W Resistive
maxima of maxima of 50WInductive
Faults Records / Event Records 5 A & 660 V. 30 A & 660V.
ASHIDA Numerical Sync Check
Communication Port Power Protection Relay
Digital Input synchronization ADR 217B
Definite time sync check protection for
Numerical U/O Frequency
MODBUS IEC-103 Protocols
paralleling two power sources. Monitoring Relay- AUOFMR2
IEC61850 availability
Adjustable phase angle limit Specification
Local HMI Adjustable time delay = Accurate Frequency
monitoring with Crystal
Large LCD display for parameter & Controlled references.
settings = Self-Calibration and check
ON-Site facility inbuilt.
Online display of line voltage & bus
= Two Independent set
voltage, CB status & all other digital & points programmable as
physical status. Under or Over Frequency.
Self diagnostic = Communication Port for
ASHIDA Numerical
Under Voltage Protection Relay
ASHIDA Numerical
Natural Displacement remote SCADA.
Latching last 10 faults with real time
ADR 232 B Protection Relay
ADR 212 E
ON
C P%100 x 0.10 HBPC ON
C P%100 x 0.10 HBPC
= AC Input from 230 / 110 /
PKP 1 E%005 x 0.01 H0.5

FAULT
PKP
1 E%005 x 0.01 H0.5
63 V AC PT for Frequency
Sensing.
ANSI IES PROTECTION FUNCTION
FAULT
RSP/LC ANSI IES PROTECTION FUNCTION
27 - DIFFERENT TIME UNDER VOLTAGE 59ND - NATURAL UNBALANCES VOLTAGE
PROTECTION
series TRIP
TRIP series

= Frequency setting Range :


MODE +/ MODE +/ Over Freq. 50.01 Hz to 65.00 Hz in steps of 0.01 Hz.
TEST
Under Freq. 40.00 Hz to 50.00 Hz in steps of 0.01 Hz.
2E

BYPASS TEST
RESET BYPASS
RESET
AD 32A
2A
21
21
2

R
R
R

Series Trip IDMT Relay


AD

Under/ Over voltage Protection Relay


AD

Flag Relay (Type : SPR3H S/T, SPR3PH S/T,SPR3 S/T & SPR3P S/T)
No of phase Under/Over voltage protection 3 1
Neutral unbalance voltage protection Suitable for interlocking, signalling etc. in
protection, control and industrial systems
1 phase Neutral displacement protection
High Voltage Insulation
Backlit LCD display for settings Low Power Consumption
Display of fault voltage / load voltage Medium or light duty operation and long
mechanical life Features:
Self supervision
Indication Flags = The relay is specially designed for situations where
Faults Latching external battery power source is not available
High resistance to shock and vibration = Wide range of TRIP point selections: 50 - 200% (O/C),
Wide under voltage range Contacts conform to IS: 3231. Duty: 20 - 80% (E/F).
1250 VA = Selectable Curve: 10 N - 3 Sec. or 10N - 1.3 Sec.
Wide over voltage range
= 2OC + 1EF or 3OC relay is available in single cabinet.
Attracted armature type compact design
Password protection for settings = Draw-out Cabinet.
with positive action
= Resetting Current : Less than 80% of set value.
IEC 103 & MODBUS protocol support Din Standard size compact cabinet = Control Contacts : The heavy-duty NC contact for
tripping and two sets of NO contacts for
RS 232 & RS 485 ports for communication Simple in construction Annunciation.
SCADA system
for sub station
Automation

FCCM3 FCCM5 FCCM4B Station Controller FRTU


Bay level SCADA module for use in ASCADA based Serves as a single Suited for
substation Automation database for RMU Automation
entire system

Continuously monitors SC has 2 RS 485 ports


Continuously monitors upto max 8 nos. Continuously monitors for communicating to slaves Supports max of 6
upto max 16 nos. digital inputs & 8 upto max 4 nos. like FCCM & Relay units and IO cards. Can be
digital inputs with digital outputs with analog inputs with Modbus divices & 2 RS232 expanded using
1 msec resolution 1 msec resolution 1 msec resolution ports for communicating with extension units
two independent masters

Clock of the FRTU can be


Any change is recorded with a time stamp with msec Data sent by the relays time synced from remote
accuracy upto 500 events. This is stored in internal or FCCMs is sent master or GPS time server
RAM until it is transferred to station controller to the control center or through SNTP protocol.

Supports protocols like


IEC 101/ SPORT,104 at Supports communication
Each card with independent microcontroller master end and 1 IEC103 on GSM/CDMA/GPRS
& Modbus at slave end

Highly stable design. Not affected by Specially Designed as


high tension switchgear operations Highly stable design. per R-APDRP model

Digital
Traction
Protection
ADR219A: ASHIDA Numerical Integrated Digital
Numerical TRACTION PROTECT
ION Traction Feeder Protection Relay
PROT.H REC
ERR AUX. OPT

DPR FAULT
LOC
-> Date Time <-
Measurment
ADR221B: ASHIDA Numerical O/C + REF
WPC PTFF
BF
Set - Bnk
Set - N/Bnk Protection Relay For Transformer
OCR TRIP
CLOSE

ADR213B : ASHIDA Numerical Single Pole


Differential Relay
ADR213D: ASHIDA Numerical Low Impedance
Bus bar protection Relay for HT side
ADR211E: ASHIDA Numerical High Impedance
ASHIDA Digital Traction Protection BUS Bar Protection Relay
Relays for Railways ADR211B: ASHIDA Numerical Definite Time Over
Current Protection Relay
Ashida Electronics is one of the major suppliers of ADR 212B: ASHIDA Numerical Under/over
Protection Relays and Control Panel for Traction voltage for Capacitor bank
www.360world.in

Systems of Indian Railways using latest numerical ADR216B: ASHIDA Numerical Reverse Power
Protection Relay
technology and having IEC open protocol so that
ADR217B: ASHIDA Numerical Sync-Check Power
it can be connected to SCADA System. Ashida Protection Relay
also supplies complete protection panels.. ADR219C: ASHIDA Vectorical Delta-I Type high
resistive fault selective relay.
APFO/2 : The APFO/2 is designed as pento
flash over relay.

Ashida Electronics Pvt. Ltd.


Ashida House, Plot No.A-308, Road No.21,
Wagle Industrial Estate, Thane-400604. INDIA
Tel : 91 22 2582 7524 /25 /26
Fax : 91 22 2580 4262
Email : sales@ashidaelectronics.com
Web : www.ashidaelectronics.com

S-ar putea să vă placă și