Sunteți pe pagina 1din 9

GLOBAL TEKNIK PERSADA STANDARD SPECIFICATIONS

DETAILED REINFORCEMENTS STANDARD FOR CONCRETE

This calculation or data sheet purposed to detailed reinforcements of concrete element for various concrete structure.

Length Distribution (Development Length) of Reinforcement with Standard Hook (Ldh)


Table Ldh for Deformed Bar (fy = 400 Mpa) According to ACI 318-05 Sect.Sect 21.5.4
f' c Deformed Bars 400 MPa
Bars Dimension 210 kg/cm 2 280 kg/cm 2 350 kg/cm 2 420 kg/cm 2 560 kg/cm 2
10 mm 210 mm 180 mm 170 mm 150 mm 130 mm
13 mm 280 mm 240 mm 220 mm 200 mm 170 mm
16 mm 350 mm 300 mm 270 mm 250 mm 215 mm
19 mm 420 mm 360 mm 330 mm 300 mm 260 mm
22 mm 490 mm 420 mm 380 mm 345 mm 300 mm
25 mm 555 mm 485 mm 430 mm 395 mm 340 mm
29 mm 630 mm 545 mm 490 mm 445 mm 385 mm
32 mm 710 mm 615 mm 550 mm 500 mm 430 mm
36 mm 750 mm 650 mm 600 mm 550 mm 480 mm

Hooked Bar Details for Development of Standard Hooks and Ldh Location According ACI 318-05

Length Distribution (Development Length) of Reinforcement without Standard Hook (Ld)


Table Ld for Deformed Bar (fy = 400 MPa) According to ACI 318-05 Sect 21.5.4
Especially for Tension Rebars
f' c Deformed Bars 400 MPa
2 2 2 2 2 2 2 2 2 2 2
Bars Dimension 200 kg/cm 225 kg/cm 250 kg/cm 300 kg/cm 350 kg/cm 400 kg/cm 425 kg/cm 450 kg/cm 500 kg/cm 550 kg/cm 600 kg/cm
10 mm 540 mm 520 mm 500 mm 450 mm 420 mm 400 mm 380 mm 370 mm 350 mm 330 mm 320 mm
13 mm 720 mm 680 mm 650 mm 580 mm 550 mm 500 mm 490 mm 470 mm 450 mm 430 mm 410 mm
16 mm 880 mm 850 mm 780 mm 710 mm 660 mm 620 mm 600 mm 580 mm 550 mm 520 mm 500 mm
19 mm 1100 mm 970 mm 920 mm 850 mm 780 mm 750 mm 720 mm 700 mm 650 mm 620 mm 600 mm
22 mm 1300 mm 1200 mm 1100 mm 1000 mm 900 mm 850 mm 820 mm 800 mm 780 mm 750 mm 700 mm
25 mm 1500 mm 1400 mm 1300 mm 1100 mm 1100 mm 1000 mm 950 mm 900 mm 880 mm 820 mm 800 mm
29 mm 1700 mm 1500 mm 1400 mm 1300 mm 1200 mm 1200 mm 1100 mm 1100 mm 1000 mm 950 mm 920 mm
32 mm 1800 mm 1700 mm 1600 mm 1500 mm 1400 mm 1300 mm 1200 mm 1200 mm 1100 mm 1100 mm 1000 mm
36 mm 1950 mm 1900 mm 1800 mm 1600 mm 1500 mm 1400 mm 1400 mm 1300 mm 1300 mm 1200 mm 1200 mm
Note :
1) for concrete elements with concrete cover 30 mm, length distribution of rebars must be using 1.3 L d
2) minimum L d for tension rebars 300 mm or for approximately value use min. 40 times of rebar diameter for critical condition
3) Calculation of development length has been added with special provisions for seismic design

Especially for Compression Rebars


f' c Deformed Bars 400 MPa
Bars Dimension 200 kg/cm 2 225 kg/cm 2 250 kg/cm 2 300 kg/cm 2 350 kg/cm 2 400 kg/cm 2 425 kg/cm 2 450 kg/cm 2 500 kg/cm 2 550 kg/cm 2 600 kg/cm 2
10 mm 210 mm 200 mm 200 mm 200 mm 200 mm 200 mm 200 mm 200 mm 200 mm 200 mm 200 mm
13 mm 280 mm 260 mm 250 mm 230 m 210 mm 200 mm 200 mm 200 mm 200 mm 200 mm 200 mm
16 mm 340 mm 320 mm 310 mm 280 mm 260 mm 240 mm 230 mm 230 mm 220 mm 210 mm 200 mm
19 mm 410 mm 380 mm 360 mm 330 mm 310 mm 290 mm 280 mm 270 mm 260 mm 240 mm 230 mm
22 mm 470 mm 440 mm 420 mm 380 mm 350 mm 330 mm 320 mm 310 mm 300 mm 280 mm 270 mm
25 mm 530 mm 500 mm 480 mm 440 mm 400 mm 380 mm 370 mm 360 mm 340 mm 320 mm 310 mm
29 mm 620 mm 580 mm 550 mm 510 mm 470 mm 440 mm 420 mm 410 mm 390 mm 370 mm 360 mm
32 mm 680 mm 640 mm 610 mm 560 mm 520 mm 480 mm 470 mm 460 mm 430 mm 410 mm 390 mm
36 mm 770 mm 720 mm 690 mm 630 mm 580 mm 540 mm 530 mm 510 mm 490 mm 460 mm 440 mm
Note :
1) minimum L d for compression rebars 200 mm
2) Calculation of development length has been added with special provisions for seismic design

Global Teknik Persada Standard Specifications 1


GLOBAL TEKNIK PERSADA STANDARD SPECIFICATIONS
DETAILED REINFORCEMENTS STANDARD FOR CONCRETE

Length Distribution Details of Rebars According ACI 318-05

Splicing of Rebars

Table Splices for Deformed Bar (fy = 400 MPa) According to ACI 318-05 Sect. 12.14 until 12.19
Splicing for Tension Rebars
Condition of Splices Length of Splices
All Condition 1.3 L d
Note : See table for Length of Distribution/Development Length of Rebars (L d )

Splicing for Compression Rebars


Bars Dimension (mm)
Bars Specification
8 10 13 16 19 22 25 29 32 36
Plain Bars (240 MPa) 300 300 - - - - - - - -
Deformed Bars (400 MPa) 300 300 370 460 540 630 710 830 910 1020
Note :
1) Minimum length of splicing : 300 mm
2) for
f Concrete
C t specification
ifi ti withith compression
i strength
t / 2 , length
th < 200 kkg/cm l th off splicing
li i should
h ld b
be 4/3 ti
times off th
the value
l iin th
the ttable
bl

Detail Splicing Location

Location of splicing rebars must be appropriated with the following requirements :


1) Rebars Position Splicing Location
Top Rebars in 0.5 L0 Area
Bottom Rebars in 0.25 L0 Area
2) Rebars of Primary Beam which it enters into column or shearwall should be installed up to the outer bars of column or shearwall
3) At least there should be two rebars which installed continuosly at a beam span on the top and bottom position
4) Splicing column must be appropriated such as the following figure :

Detail Offset of Rebars for Splicing Rebars at Column According ACI 318-05

Global Teknik Persada Standard Specifications 2


GLOBAL TEKNIK PERSADA STANDARD SPECIFICATIONS
DETAILED REINFORCEMENTS STANDARD FOR CONCRETE

5) At base section or base elevation of concrete column, there should be no splicing of rebars or all rebars must be installed
continuously until the middle area of next elevation
6) The position of rebars splicing shall not be placed at maximum stress area of concrete elements
7) Especially for rebars with D 32 mm, the splicing must be using mechanic connection (must be using welded connection)
8) Rebars splicing shall not be placed at connection area between primary beam and secondary beam of concrete elements

Development Length and Splicing for Spiral Bars


Development length and splicing for spiral bars according to ACI 318-05 shown in the following figure :

Detail Anchoring for Spiral Bars at End and Starting Section

Detail Anchoring and Splicing for Spiral Bars at Connecting Area

Note :
1) Spiral bars must be have full lap minimum 1.5 times of bars dimater or 25 mm or the same with clearance distance between vertical
bars without disconnected
2) The length of splices minimum must be 50 times of spiral bars diameter or larger than 300 mm and at end section must be anchoraged.

Global Teknik Persada Standard Specifications 3


GLOBAL TEKNIK PERSADA STANDARD SPECIFICATIONS
DETAILED REINFORCEMENTS STANDARD FOR CONCRETE

Splicing for Wiremesh of Concrete Slab


Splicing for wiremesh of concrete slab must be using the following equation :

Ld = 1.043 (Aw/Sw) (fy/f'c0.5) (Modification Equation Based on ACI 318-05 Sect.12.8 )


Where :
A w = Cross sectional Area of 1 Rebar (cm 2 )
S w = The distance between rebars (cm)
f y = Min.Yield Strength of Main Rebars (kg/cm 2 )
f' c = Min. Compression Strength of Concrete Element at 28 Days (kg/cm 2 )
Ld = Splicing of rebars (cm)

Note :
1) Minimum length of splicing : 300 mm or must be larger than 40 times of rebar diameter for critical condition

Joint in concrete slab or wall construction to decrease crack area caused by shrinkage and temperature change shown in the following Table :

Global Teknik Persada Standard Specifications 4


GLOBAL TEKNIK PERSADA STANDARD SPECIFICATIONS
DETAILED REINFORCEMENTS STANDARD FOR CONCRETE

Detail Reinforcement for Corbel Beam


Detail reinforcement for corbel beam shown in the following figure :

Detail Reinforcement for Corbel Beam (ACI 318-05 Sect.11.9 )

Detail Installation for Stirrups


Detail installation for stirrups shown in the following figure :

Length of Hook for Stirrups (Note : Length of Stirrups must be larger than 75 mm )

Close Stirrups Must Be Installed with Different Intervals at Beam Span


Note :
1) First stirrup must be installed 50 mm from the front of column until along 2 times of beam height or 0.25 times of beam span

Global Teknik Persada Standard Specifications 5


GLOBAL TEKNIK PERSADA STANDARD SPECIFICATIONS
DETAILED REINFORCEMENTS STANDARD FOR CONCRETE

Typical Detail Reinforcement for Concrete Structure

Typical Reinforcement Detail for Tranch

Typical Reinforcement Detail for Foundation Block

Typical Reinforcement Detail for Slabless Staircase

Global Teknik Persada Standard Specifications 6


GLOBAL TEKNIK PERSADA STANDARD SPECIFICATIONS
DETAILED REINFORCEMENTS STANDARD FOR CONCRETE

Typical Reinforcement Detail for Staircase With Waist Slab

Typical Reinforcement Detail for Non-Prismatic Beam

Typical Reinforcement Detail for Sloping Beam

Global Teknik Persada Standard Specifications 7


GLOBAL TEKNIK PERSADA STANDARD SPECIFICATIONS
DETAILED REINFORCEMENTS STANDARD FOR CONCRETE

Typical Reinforcement Detail for Haunch Beam

Typical Reinforcement Detail for Corbel Beam

Termination of Column Bars Inside Beam

Global Teknik Persada Standard Specifications 8


GLOBAL TEKNIK PERSADA STANDARD SPECIFICATIONS
DETAILED REINFORCEMENTS STANDARD FOR CONCRETE

Typical Reinforcement Detail for Opening in Web Beam

Typical Reinforcement Detail for Connection between Main & Secondary Concrete Beam

Typical Reinforcement Detail for Grid Concrete Beam

Global Teknik Persada Standard Specifications 9