Documente Academic
Documente Profesional
Documente Cultură
FB08-15
Date July 2008
BULLETIN
Field Product Type IPSO and Cissell Washer-Extractors and Tumblers
Purpose Announcement
Interchangeable N/A
Subject Error Codes
On the following pages is a list of error codes for the IPSO and Cissell line of Washer-Extractors
and Tumblers. For additional information on the programming of these machines refer to the
Programming Manual.
Control Types
Micro 9
Micro 20
PC 30
PS40
PS40F
Sigma
DX4
Cygnus
Group 1
Error Code Probable Cause Possible Corrective Actions
E4 (water level) Water level was not reached after Check inlet water filters
five minutes.
Check water pressure
Table 1
Page 2 of 18 FB08-15
Error Codes
NOTE: * To clear the not 3 error code: coin or vended machines - go to program D and press ECO button
(E). OPL models - Press the ECO button (E) and SELECT button (P) simultaniously. The letter d will
appear on the right side, press the ECO button (E) once again. For additional information refer to
instruction manual 249/00368/10.
Group 2
Error Code Probable Cause Possible Corrective Actions
E7 (safety level) Water did not drain sufficiently. Check the drain pump
Check contacts A, B, C or D of
MICRO 9 control
Table 2
FB08-15 Page 3 of 18
Error Codes
Page 4 of 18 FB08-15
Error Codes
FB08-15 Page 5 of 18
Error Codes
Page 6 of 18 FB08-15
Error Codes
FB08-15 Page 7 of 18
Error Codes
There is a test program built into the PC30 - the access code is E 227.
The door lock mechanism has 3 switches S1 (Door Closed switch input), S2 (Door Locked switch input) and
S3 (Stops the signal from the door lock print board to the door lock coil, when the S2 switch is closed and the
program starts).
The resistor on the PC30 print board for the relay drain 1 has to be removed when the drain valve operates with
an addtional relay.
Page 8 of 18 FB08-15
Error Codes
NOTE: Certain error indicators will prevent the start of a cycle or stop a cycle in progress until corrected.
FB08-15 Page 9 of 18
Error Codes
Page 10 of 18 FB08-15
Error Codes
FB08-15 Page 11 of 18
Error Codes
Table 6
Page 12 of 18 FB08-15
Error Codes
BOOT 100 appears on the display during Start up or Boot Memory - E Prom.
Additional memories can be downloaded via the optical connection in the control panel.
The Program Memory contains data for the function of the machine. The software version is displayed at the
Start up (i.e. IPSO 100 appears indicating version 1.00)
The Data Memory contains the washing date (i.e. temperature, levels, speed, etc)
Boot 100 appears after Code Err and Data Err and the control expects code to be loaded.
FB08-15 Page 13 of 18
Error Codes
Page 14 of 18 FB08-15
Error Codes
FB08-15 Page 15 of 18
Error Codes
ERROR 15 (Level Sensor Error) At startup the water level is Check inlet water supply
lower than 4cm, higher than 2cm
(positive offset) or higher than Inspect inlet water valves
10cm (negative offset)
Inspect drain valve
Check wiring
ERROR 20 (ID Chip Write Error by a writing action to the Program correct action to the
Error) identification chip ID Chip
Check wiring
ERROR 21 (MMC Transfer Error during the transfer of data Check wiring
Error) to MMC Card
ERROR 22 (Door lock Error) Door will not lock after 5 failed Check door lock circuit
attempts in 10 seconds
Inspect door lock mechanism
ERROR 23 (Wash Data Version The wash data is not Reprogram wash data
Error) corresponding with the type of
display
ERROR 24 (Wrong Display Wrong display type programmed Check display type
Type Error)
ERROR 25 (Wash Data Backup Wash data will not backup Check wiring
Error)
Check for sufficient space to
save backup data
Page 16 of 18 FB08-15
Error Codes
Check wiring
ERROR 29 (RTC Writer Error) Error by a writing action to the Program correct action to the
RTC RTC
Check wiring
ERROR 30 (EProm Read Error) Error when reading EProm Verify correct EProm is in
machine
Check wiring
ERROR 31 (EProm Write Error) Error by a writing action to the Program correct action to the
EProm EProm
Check wiring
ERROR 32 (Water Level Too The water level was too low Check inlet water supply
Low) during the heating cycle
Inspect inlet water valves
FB08-15 Page 17 of 18
Error Codes
Table 9
Page 18 of 18 FB08-15