"Now You Know What Your Revised 04-04


Catalog Section 30 & 78

Engine Is Telling You"


(00-02-0533)

k 2nd s MurphyLink Series M310 Panels


h y Lin anel Standard panel designed for modern electronic engines
rp P
Mu ration and equipment applications using SAE J1939 Controller
e Area Network (CAN)
Gen
PowerView displays over 30 standard SAE J1939 para-
Typical Application Shown,
Features Vary Per Engine
meters broadcast by major engine and transmission
Application manufacturers ECUs
Display active faults and ECU-stored faults with text
description on most common faults for diagnosing
equipment malfunctions
Standard harnesses available for most major engine
manufacturers ECUs
Enclosed design or flat panel option
Deutsch connectors
Description Display Parameters
Introducing the new M310 Series panels using The PowerView has four buttons using touch- The following are some of the engine and
the new PowerView System. It is available in an sensitive technology, which eliminates the con- transmission parameters displayed by the
enclosure or stand-alone flat panel option that cern for push button wear and failure. In addition PowerView in English or Metric units
can be dropped into a dash. The PowerView is a operators can navigate the display with ease. (when applicable), consult engine or
powerful new display in a line of components Enhanced alarm indication uses ultra bright transmission manufacturer for SAE J1939
manufactured as part of its J1939 MurphyLink alarm and shutdown LEDs (amber and red). The supported parameters.
Family. These products have been developed to PowerView has a wide operating temperature
range of -40 to +85 C (-40 to185 F), display Engine RPM
meet the needs for instrumentation and control
on electronically controlled engines communicat- viewing -40 to +75 C (-40 to 167 F), and envi- Engine Hours
ing using the SAE J1939 Controller Area ronmental sealing to +/- 5 PSI. Machine Hours
Network (CAN). Other components in the panels are microproces- System Voltage
The M310 Series Panels include the PowerView sor-based M-Link PowerView Analog Gages % Engine Load at the Current RPM
and the Mlink PowerView Analog Gages. The for displaying critical engine data broadcast by Coolant Temperature
PowerView is a multifunction tool that enables an electronic engine: engine RPM, oil pressure, Oil Pressure
equipment operators to view many different coolant temperature, system voltage, etc. and an Fuel Economy
engine or transmission parameters and service optional audible alarm and relay unit for warning Throttle Position
codes. The panels provide a window into modern and shutdown annunciation.
Engine Manifold Air Temperature
electronic engines. The PowerView includes a
graphical backlighted LCD screen. It has excel-
This standard panel can be ordered with or with- Current Fuel Consumption
lent contrast and viewing from all angles. The
out an enclosure, since all of the components are
assembled to a stand-a-lone flat panel. Optional
Transmission Gear Oil Pressure
display can show either a single parameter or a mounting kits are offered for the enclosure, Transmission Gear Oil Temperature
quadrant display for viewing four parameters which provide packagers and operators numer- Transmission Gear Position
simultaneously. Diagnostic capabilities include ous mounting solutions to meet multiple applica- Active Service Codes
fault codes with text translation for the most tions. Panel designs are offered to meet the needs Stored Service Codes from the Engine
common fault conditions. of specific engine models. In addition, Set Units for Display (English or Metric)

CALL MURCAL TO PLACE YOUR ORDER


FWMurphy offers standard harnesses for quick
Plug and Go operation that interface with all the
View Engine Configuration Parameters

2nd Generation MurphyLink Powerview panels.

MurCal
c

M310-03022B page 1 of 8
P:(661)272-4700 F:(661)947-7570
www.murcal.com e-mail: sales@murcal.com
Dimensions Flat Panel (only) Dimensions in Enclosure
Includes Shock Mounts Includes Shock Mounts

.75 in. min See Note 2 for


9.50 in. (241 mm) (19 mm) Mounting Depth
8.50 in. (216 mm) 9.93 in. (252 mm) 6.62 in. (168 mm)
SHOCK MOUNT 7.50 in. (190 mm) 5.87 in. (149 mm)

1.19 in. (30 mm)

SHOCK MOUNT

SERVICE DIAGNOSTIC

WARNING
13 in.
(330 mm) FRONT VIEW
PANEL REMOVED

(360 mm)
14.16 in.
14 in.
(356 mm)

(305 mm)
12 in.
.28 TYP. OF 4
SHOCK MOUNT (7 mm)

.25 in. 5.15 in. (131 mm)


(6 mm) 5.91 in. (150 mm)
SIDE VIEW SIDE VIEW

NOTE 1: Flat Panel has approximately 8 inch leads on connectors.


Typical application shown, features vary per engine application.
NOTE 2: Allow 4.50 in.( 114 mm) minimum mounting depth for versions with
Morse throttle. For all other version allow 3.25 in. (83 mm) minimum depth.

Surface Mount Dimension Recessed Mount Dimension


(optional) Kit P/N 32-00-0033 (optional) Kit P/N 32-00-0035

6.69 in 9 in (229 mm)


(170 mm) 5.99 in (152 mm) 9 in (229 mm)
5.47 in 7.50 in (190 mm)
4.64 in (118 mm)
(139 mm) 7.50 in (190 mm)

16 in
(406 mm)

17.10 in
(434 mm)

16 in 17.18 in
(406 mm) (436 mm)

.25 in.
(6 mm)

SIDE VIEW FRONT VIEW .25 in.


(6 mm)
SIDE VIEW FRONT VIEW

NOTE : It is the users responsibility to verify that the electronic control module (ECM) has
been programmed to support these control features, and that the appropriate external wire
harness or other interconnecting wiring has been installed from the panel to the ECM .

M310-03022B page 2 of 8
How to Order
To order, use the model number designation diagram below.

M-LINK M310 Panel Model Number Configurator for


CUMMINS Engines

Example: M31CU A1 24 B FP
Base Model No.
M31CU Blank = Enclosure (includes 4 shock mounts)
FP = Flat Panel (includes 4 shock mounts)
ENGINE/ECM CODE
A1 = Cummins QSB/QSC Control Codes
(QSB5.9, QSC8.3) Select one:
B1 = Cummins QSK A = DS,ID *(Please refer to Pricing Guide
(QSK19, QSK45, QSK60) B = DS,ID,RI for available panel-models)
C1 = Cummins QSM/QSX C = MT,DS,ID
(QSM, QSX15)
Code Descriptions:
Contact FWMurphy sales if your engine is DS = Diagnostic Switch (Mom)
not listed ID = Increment/Decrement (Mom)
RI = Run/Idle Switch
MT = Morse Throttle
DC Voltage
12 Lamp Configurations
24 Information Only, specified by ECM Code
QSB/QSC = 5 Lamps
(Service, Shutdown, Warning
Standard M-LINK Instruments Provided:
Wait to Start, Water in Fuel)
PowerView, Oil Pressure, Coolant Temperature, Battery Voltage,
Tachometer QSK = 3 Lamps
(Service, Shutdown, Warning)
Additional Indicator Options QSM/QSX = 4 Lamps
(choose up to 2 or none) (Service, Shutdown, Warning
= None Wait to Start)
Optional M-LINK Gauges
AA = Audible Alarm Optional Mounting Brackets
PL = Percent Load Gauge To be used with Enclosure
TP = Transmission Oil Pressure Gauge* (Not applicable to FP, Flat Panel)
TT = Transmission Oil Temperature Gauge* 32-00-0033 = Surface Mounting Kit
* = Verify engine model broadcasts this information using auxiliary J1939 32-00-0035 = Recessed Mounting Kit
parameters from ECU. Note: Kits include hardware and brackets.

*Panels not in Pricing Guide can be quoted, but may have longer lead times.

M-LINK External Harnesses for


CUMMINS Engines
Example: MEH-M1 A1 6

Base Model No.


HARNESS LENGTH: ft (m)
6 ft. (1.8)
12 ft. (3.6)
ENGINE/ECM CODE 20 ft. (6.1)
A1 = Cummins QSB/QSC 30 ft. (9.1)
(QSB5.9, QSC8.3)
B1 = Cummins QSK
(QSK19, QSK45, QSK60)
CALL MURCAL TO PLACE YOUR ORDER C1 = Cummins QSM/QSX
(QSM11, QSX15)
NOTE: All CUMMINS external harnesses
Contact FWMurphy sales if your include wiring for Morse Throttle, Diagnostic

MurCal
c engine is not listed Switch and Increment/Decrement Switch.

P:(661)272-4700 F:(661)947-7570
www.murcal.com e-mail: sales@murcal.com
M310-03022B page 3 of 8
How to Order, continued
To order, use the model number designation diagram below.

M-LINK M310 Panel Model Number Configurator for


CATERPILLAR EnginesADEM3 ECM

Example: M31CA A4 24 C FP
Base Model
M31CA Blank = Enclosure (includes 4 shock mounts)
FP = Flat Panel (includes 4 shock mounts)
ENGINE/ECM CODE
A4 = Caterpillar - ADEM3 Control Codes
(3176C, 3196, 3406E, 3408E, 3456,
3508EUI, C9, C10, C12, C15, C16, 3126B, Select one:
3412E (engines with ADEM3 ECM)
A = MR, PT
Contact FWMurphy sales if your engine is B = MR, wiring only for MT
not listed C = MR, MT, installed
Code Descriptions:
MR = Maintenance Due Reset Switch (Mom)
DC Voltage PT = PTO Ramp Up/Ramp Down With Inc/Dec
12 Switch (Mom)
24 MT = Morse Throttle (PWM)
Lamp Configurations
Information Only, specified by ECM Code
Standard M-LINK Instruments Provided:
ADEM 3 = 3 Lamps
PowerView, Oil Pressure, Coolant Temperature, Battery Voltage,
(Service, Diagnostic, Warning)
Tachometer
Additional Indicator Options
Optional Mounting Brackets
(choose up to 2 or none) To be used with Enclosure
= None (Not applicable to FP, Flat Panel)
Optional M-LINK Gauges 32-00-0033 = Surface Mounting Kit
AA = Audible Alarm 32-00-0035 = Recessed Mounting Kit
PL = Percent Load Gauge Note: Kits include hardware and brackets.
TP = Transmission Oil Press. Gauge*
TT = Transmission Oil Temp. Gauge*
* = Verify engine model broadcasts this information.

M-LINK External Harnesses for


CATERPILLAR ADEM3 Engines
Example: MEH-M1 A4 6

Base Model No.


HARNESS LENGTH: ft (m)
6 ft. (1.8)
ENGINE/ECM CODE 12 ft. (3.6)
A4 = Caterpillar - ADEM3 20 ft. (6.1)
(3176C, 3196, 3406E, 3408E, 3456, 30 ft. (9.1)
3508EUI, C9, C10, C12, C15, C16,
3126B, 3412E
Contact FWMurphy sales if your engine NOTE: All CATERPILLAR external harnesses
is not listed support wiring for Morse Throttle, PTO
Control, and Maintenance Reset Switch.

M310-03022B page 4 of 8
How to Order, continued
To order, use the model number designation diagram below.

M-LINK M310 Panel Model Number Configurator for


PERKINS Engines1100 Series or
CATERPILLAR3000 Series (ADEM4 ECM)
Example: M31PK B3 24 C FP

Base Model Blank = Enclosure (includes 4 shock mounts)


M31PK FP = Flat Panel (includes 4 shock mounts)

Engine/ECM Code Control Codes


B3 = Perkins-1100 Series (1104, 1106)
Caterpillar-3000 Series (3054E, 3056E) Select one:
Contact FWMurphy sales if your engine is C = Single speed, no adjust
not listed E = Run/Idle speed select
F = Inc/Dec on speed

DC Voltage Lamp Configurations


12 Information Only,
24 Options C-F = 2 Lamps
(Warning, Stop)

Standard M-LINK Instruments Provided:


PowerView, Oil Pressure, Coolant Temperature, Battery Voltage, Optional Mounting Brackets
Tachometer To be used with Enclosure
(Not applicable to FP, Flat Panel)
Additional Indicator Options 32-00-0033 = Surface Mounting Kit
(choose up to 2 or none) 32-00-0035 = Recessed Mounting Kit
= None Note: Kits include hardware and brackets.
Optional M-LINK Gauges
AA = Audible Alarm
PL = Percent Load Gauge

M-LINK External Harnesses for


PERKINS1100 Series or CATERPILLAR3000 Series (ADEM4 ECM)

Example: MEH-M1 B3 6

Base Model No.


HARNESS LENGTH: ft (m)
6 ft. (1.8)
ENGINE/ECM CODE 12 ft. (3.6)
B3** = Perkins - 1100 Series 20 ft. (6.1)
(1104, 1106) 30 ft. (9.1)
Caterpillar - 3000 Series
(3054E, 3056E)
**HARNESS REQUIRES RELAY(S) SEE NOTE: All PERKINS/CATERPILLAR external
BELOW harnesses support wiring for Single Speed,
Run/Idle and Increment/Decrement
Contact FWMurphy sales if your engine
is not listed

**HARNESS REQUIRES RELAY(S)


(B3)
00008799 = 12V Relay [1104/3054E (2) Required, 1106/3056E (1) Required]
00008800 = 24V Relay [1104/3054E (2) Required, 1106/3056E (1) Required]
NOTE: Relays sold separately. Relays must have minimum 30 amp contact rating.
CALL MURCAL TO PLACE YOUR ORDER

MurCal
c

P:(661)272-4700 F:(661)947-7570
www.murcal.com e-mail: sales@murcal.com M310-03022B page 5 of 8
How to Order, continued
To order, use the model number designation diagram below.

M-LINK M310 Panel Model Number Configurator for


PERKINS Engines1300 Series or
DETROIT DIESELSeries 40
Example: M31PK A3 24 A FP

Blank = Enclosure (includes 4 shock mounts)


Base Model
FP = Flat Panel (includes 4 shock mounts)
M31PK

Engine/ECM Code
A3 = Perkins 1300 Series
Detroit Series 40
(I0PU/I0PU3/I0PU4) Control Codes
Contact FWMurphy sales if your engine is not
listed Select one:
A = DS, IOPU2
B = DS, IOPU3/IOPU4
DC Voltage
Code Descriptions:
12 IOPU2= Standard Throttle (Resistive Potentiometer)
24 IOPU3/IOPU4 = Variable/Preset Includes
Variable/Preset Switch and Inc/Dec Switch (Mom)
DS = Diagnostic Switch (Mom)
Standard M-LINK Instruments Provided: Included Sensors
PowerView, Oil Pressure, Coolant Temperature, Battery Voltage, Barometric Air Pressure
Tachometer Ambient Air Temperature
(APS trim pot included with either)
Additional Indicator Options
(choose up to 2 or none) Lamp Configurations
= None Information Only, specified by ECM Code
Optional M-LINK Gauges 1300 Series= 2 Lamps
AA = Audible Alarm (Warning, Shutdown)
PL = Percent Load Gauge

Optional Mounting Brackets


To be used with Enclosure
(Not applicable to FP, Flat Panel)
32-00-0033 = Surface Mounting Kit
32-00-0035 = Recessed Mounting Kit
Note : Kits include hardware and brackets.

M-LINK External Harnesses for


PERKINS 1300 Series or DETROIT DIESELSeries 40 Engines
Example: MEH-M1 A3 6

Base Model No.


HARNESS LENGTH: ft (m)
ENGINE/ECM CODE 6 ft. (1.8)
A3* = Perkins - 1300 Series 12 ft. (3.6)
Detroit Diesel Series 40 20 ft. (6.1)
(I0PU2/I0PU3/I0PU4) 30 ft. (9.1)

*HARNESS REQUIRES RELAY SEE BELOW


Contact FWMurphy sales if your engine is
not listed
CALL MURCAL TO PLACE YOUR ORDER

*HARNESS REQUIRES RELAY NOTE: All PERKINS 1300 Series/DETROIT

MurCal
(AO3)
c
DIESEL Series 40 external harnesses support
00008799 = 12V Relay wiring for both throttle control and
00008800 = 24V Relay Variable/Preset select with
P:(661)272-4700 F:(661)947-7570 NOTE: Relay sold separately. Relay must have minimum Increment/Decrement.
www.murcal.com e-mail: sales@murcal.com 30 amp contact rating.

M310-03022B page 6 of 8
How to Order, continued
To order, use the model number designation diagram below.

M-LINK M310 Panel Model Number Configurator for


DETROIT DIESEL EnginesSeries 50/60 and Series 2000

Example: M31DD A2 24 B FP
Base Model
M31DD
Blank = Enclosure (includes 4 shock mounts)
FP = Flat Panel (includes 4 shock mounts)
Engine/ECM Code
A2 = DD50/60 Series
(DDEC III, DDEC IV) Control Codes
B2 = DD 2000 Series
(DDEC III, DDEC IV) Select one:
A = DS, MT
Contact FWMurphy sales if your engine is not
B = ES, DS, MT
listed
Code Descriptions:
MT = Analog Morse Throttle
DC Voltage DS = Diagnostic Switch (Mom)
12 ES = Emergency Stop Switch
24 Lamp Configurations
Information Only, specified by ECM Code
Standard M-LINK Instruments Provided: DDEC III, IV= 2 Lamps
PowerView, Oil Pressure, Coolant Temperature, Battery Voltage, (Stop Engine, Check Engine)
Tachometer

Additional Indicator Options


(choose up to 2 or none) Optional Mounting Brackets
To be used with Enclosure
= None
(Not applicable to FP, Flat Panel)
Optional M-LINK Gauges 32-00-0033 = Surface Mounting Kit
AA = Audible Alarm 32-00-0035 = Recessed Mounting Kit
PL = Percent Load Gauge Note: Kits include hardware and brackets.

M-LINK External Harnesses for


DETROIT DIESELSeries 50/60 and Series 2000

Example: MEH-M1 A2 6

Base Model No. HARNESS LENGTH: ft (m)


6 ft. (1.8)
12 ft. (3.6)
ENGINE/ECM CODE 20 ft. (6.1)
A2 = DETROIT DIESEL 50/60, 2000 Series 30 ft. (9.1)
(DDEC III, DDEC IV)
Contact FWMurphy sales if your engine is
NOTE: DETROIT DIESEL external harnesses
not listed
support wiring for Morse throttle control and
supports the emergency-stop panel

CALL MURCAL TO PLACE YOUR ORDER

MurCal
c

P:(661)272-4700 F:(661)947-7570
www.murcal.com e-mail: sales@murcal.com
M310-03022B page 7 of 8
Warranty
A limited warranty on materials and workmanship is given with this FW Murphy product.
A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm

CALL MURCAL TO PLACE YOUR ORDER

MurCal
c

P:(661)272-4700 F:(661)947-7570
www.murcal.com e-mail: sales@murcal.com
RE

GI
ST ER
E

USAISO 9001:2000 FM 28221


UKISO 9001:2000 FM 29422

Printed in U.S.A.

M310-03022B page 8 of 8

S-ar putea să vă placă și