Sunteți pe pagina 1din 2

INDRA GANESAN COLLEGE OF ENGINEERING INDRA GANESAN COLLEGE OF ENGINEERING

EE6801 ELECTRIC ENERGY GENERATION, UTILIZATION AND CONSERVATION EE6801 ELECTRIC ENERGY GENERATION, UTILIZATION AND CONSERVATION
DEPARTMENT OF EEE UNIT TEST- 2 (FN) DEPARTMENT OF EEE UNIT TEST- 2 (FN)
PART A: 9*2=18 PART A: 9*2=18
1. State the law of illumination? 1. State the law of illumination?
2. Distinguish between direct lighting and indirect lighting? 2. Distinguish between direct lighting and indirect lighting?
3. Define illumination? 3. Define illumination?
4. Define the term lux? 4. Define the term lux?
5. What are the type of lamps? 5. What are the type of lamps?
6. What is MSCP and MHSCP? 6. What is MSCP and MHSCP?
7. Define space-height ratio. 7. Define space-height ratio.
8. Depreciation factor? 8. Depreciation factor?
9. What is maintenance factor.? 9. What is maintenance factor.?

PART B: 2*16=32 PART B: 2*16=32

10. i)Draw and explain solid angle (4) 10. i)Draw and explain solid angle (4)
ii)Define and derive the law of illuminations (12) ii)Define and derive the law of illuminations (12)
(OR) (OR)
b)i) with a neat diagram explain the working of i)Fluorescent lamp b)i) with a neat diagram explain the working of i)Fluorescent lamp
ii)Compact Fluorescent lamp iii) mercury vapour lamp (16) ii)Compact Fluorescent lamp iii) mercury vapour lamp (16)

11. a)i)Two street lamps are 20m apart and fitted with 500 c.p lamp at a height of 11. a)i)Two street lamps are 20m apart and fitted with 500 c.p lamp at a height of
8m above the ground .Find the illumination at point under the lamp post and 8m above the ground .Find the illumination at point under the lamp post and
midway between the lamps . (8) midway between the lamps . (8)

ii)A building measuring 25x25 m is t be flood hit on the front side with bright ii)A building measuring 25x25 m is t be flood hit on the front side with bright
ness of 30 lumens/sq.metre. Co-efficient of reflection of building surface is ness of 30 lumens/sq.metre. Co-efficient of reflection of building surface is
0.25 lamps of 475w having lumens output of 8000 each are used. Assuming 0.25 lamps of 475w having lumens output of 8000 each are used. Assuming
beam factor as 0.6 ,waste light factor 1.2 and maintenance factor as 0.75 beam factor as 0.6 ,waste light factor 1.2 and maintenance factor as 0.75
.Determine the number of lamps required (8) .Determine the number of lamps required (8)
(OR) (OR)

b) i) Draw and explain the Incandescent Lamp (8) b) i) Draw and explain the Incandescent Lamp (8)
ii) the flux emitted by lamp is all direction is 600 lumens. Calculate its ii) the flux emitted by lamp is all direction is 600 lumens. Calculate its
a)MSCP b)The CP of Lamp is 120 .A plane surface is place at a distance of 2 a)MSCP b)The CP of Lamp is 120 .A plane surface is place at a distance of 2
meter from this lamps .calculate the illumination on the surface when it is .normal meter from this lamps .calculate the illumination on the surface when it is .normal
2. Inclined to 45 3.Paralle to rays (8) 2. Inclined to 45 3.Paralle to rays (8)

. .