Angle Steel Member Capacity Based on AISC 360-10

INPUT DATA & DESIGN SUMMARY


ANGLE SIZE L8X6X1
STEEL YIELD STRESS Fy = 36 ksi

AXIAL COMPRESSION FORCE P= 10 kips, ASD


STRONG GEOMETRIC AXIS EFFECTIVE LENGTH kLx = 20 ft
WEAK GEOMETRIC AXIS EFFECTIVE LENGTH kLy = 10 ft

STRONG GEOMETRIC AXIS BENDING MOMENT Mrx = 5 ft-kips, ASD


STRONG GEOMETRIC AXIS BENDING UNBRACED LENGTH Lbx = 20 ft, (AISC 360-10 F2.2.c)
STRONG DIRECTION SHEAR LOAD, ASD Vstrong = 77 kips

WEAK GEOMETRIC AXIS BENDING MOMENT Mry = 6 ft-kips, ASD


WEAK GEOMETRIC AXIS BENDING UNBRACED LENGTH Lby = 10 ft
WEAK DIRECTION SHEAR LOAD, ASD Vweak = 60 kips

THE DESIGN IS ADEQUATE.

ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-10, H1)

P r 8 M r ,max M r ,min P r 0.2


, for
P c 9 M c ,max M c ,min Pc
<
0.91 1.0 [Satisfactory]
P r M r ,max M r ,min P r 0.2
, for
2 P c M c ,max M c ,min Pc
Where Pc = Pn / c = 136 / 1.67 = 81.28 kips, (AISC 360-10 Chapter E5)
> Pr [Satisfactory]
Mr,max = 7.78 ft-kips or 0.71 ft-kips ,(major principal axis bending)
Mr,min = 0.71 ft-kips or 7.78 ft-kips ,(minor principal axis bending)
Mc,max = Mn / b = 42.24 / 1.67 = 25.29 ft-kips, (smaller equal-leg section used, AISC 360-10 Chapter F10-2)
> Mr,max [Satisfactory]
Mc,min = Mn / b = 15.89 / 1.67 = 9.51 ft-kips
> Mr,min [Satisfactory]

CHECK SHEAR CAPACITY (AISC 360-10, G2)


Vn,strong / v = 172.8 / 1.67 = 103.5 kips > Vstrong = 77.0 kips [Satisfactory]

Vn,weak / v = 129.6 / 1.67 = 77.6 kips > Vweak = 60.0 kips [Satisfactory]