Sunteți pe pagina 1din 1

AUTOMATIC GREASE RECOVERY UNITS R-AGRU SERIES

OVERVIEW
Automatic Grease Recovery Unit

SEPARATORS
GREASE
Intermittent Threaded Greasy Top to Center Bottom to Center
Flow Inlet and Sludge of Inlet/Outlet of Inlet/Outlet Width Length Height
Model GPM Outlet Capacity B C D E F
R-AGRU-20 20 2" 40lb. 4.5" 10" 18" 30" 14.5"
R-AGRU-25 25 3" 50lb. 4.0" 10.5" 18" 30" 14.5"

INTERCEPTORS
GREASE
R-AGRU-35 35 4" 70lb. 4.5" 12.5" 18" 36" 17"
R-AGRU-50 50 4" 100lb. 4.5" 17" 18" 36" 17"
R-AGRU-75 75 4" 150lb. 4.5" 17" 24" 42" 21.5"
R-AGRU-100 100 4" 200lb. 4.5" 17" 24" 42" 21.5"

AUTOMATIC
GREASE
SERIES
Larger Units Available.

Job Specification: Automated Grease Recovery Units shall be Rockford Separators as manufactured by Rockford Sanitary Systems, Inc.,
Rockford, Illinois, and as noted on plans.
Separator Specifications: Furnish ____Rockford Model R-AGRU-____ constructed of 304 stainless steel, all TIG welded, hydrostatically

SEPARATORS
tested and polished to a 2B finish and inspected to be free from defects. Unit is rated for ____ g.p.m. intermittent flow, and ____ lb.

OIL
of grease retention capacity with 4.00" threaded inlet and outlet connections. All components are also constructed of 304 stainless
steel including the internal parts, gasketed cover, internal strainer basket, and electronics control housing box. Grease removal shall be
preformed by a 7 day multi-event capable timer controlling an electric draw-off valve and a thermostatically controlled heating element.
The free floating grease shall be removed automatically as required per application to a collection box for proper disposal or recycling.

INTERCEPTORS
Unit is regularly supplied with threaded flow control fitting. Please note that disconnect and wiring to the unit are supplied by others.

FUEL
Electrical Requirements: 120 volt, 15 amp. The unit should be connected to an electrical circuit controlled by a ground fault circuit
breaker. Consult your local code for proper installation.
Optional Feature: Integral grease containment drawer with level- and presence-sensing.

Specify at time of order Left to Right or Right to Left flow while facing control panel.

SEPARATORS
LINT
D

SEDIMENT
E

SAND/
B
F DRAINS

C Larger Units Available.


Call for specifications.
BASINS
REPLACEMENT
PARTS

800.747.5077
Fax: 815.229.5108
45