Sunteți pe pagina 1din 1

Must do Can be

Current Lab Measurements Remarks


removed
Color Code method can be used. Can be
Bottom Discharge Oil
removed from the list.
Percentage
Must do. Instead of every batches it can be done
Bottom Discharge Oil (Color
one after one batch for each CF tanks.
Code Method)
Visual inspection method can be used. Can be
Press Fiber Oil Percentage removed from the list.

No use. Can be removed from the list


Press Out Oil Percentage
Centrifuge Out Oil Must do. Can be done twice per shift
Percentage
As we control the bottom oil content it can be
Decanter Solids Oil removed from the list. Also visually
Percentage identification can be used.

No use as we control the bottom oil content.


Decanter Inlet Oil Percentage Viscosity measurement can be used whenever
the decanter water adding necessary.
No use. In our current process we are unable to
control the CF1 underflow oil content for a
CF 1 Underflow Oil
longer time period without changing the current
Percentage
process.

Must do to decide the kernel expeller screw


Kernel Meal Oil Percentage should be changed. Can be done only for the 2nd
expeller.
Must do. Can be measured impurities only in the
Impurities (CPO)
CPO storage tank.
Must do. Can be measured impurities only in the
Impurities (CKO)
CKO storage tank.