iPQ-Workflow installation
Installation of iPQ-Workflow
1. Modules of iPQ-Workflow
1.1 Member of the iPQ-Workflow system
iPQ-Check / iPQ-View
o Inspection of printed materials
o Generation one printing protocols per reel
Data Server
o Fetching protocols from iPQ-Check / iPQ-View
o Managing and distributing protocols
Quality Assurance
o Fetch available reels from data server and display them
o Display reel defects in a rollmap
o Edit the detected defects and define waste
o Write changes back to the Data Server
Report Generator
o Fetch available reels from Data Server and display them
o Create PDF report for selected reel
Rewinder Control
o Fetch available reels from Data Server and display them
o Display reel defects and waste in a rollmap
o Control of the rewinder (SlowDown, FinalStop)
o Skip defects when rewinding the reel
o Define waste when rewinding the reel
o Write changes back to the Data Server
Data Server
Data Server
1.3.2 Quality Assurance/ Report Generator and Data Server on one computer
Data Server
Data Server
Data Server
2. System requirements
2.1 Data Server
Data flow within iPQ-Workflow is carried out via reel protocols in XML format. A central Data
Server is installed to enable every iPQ-Workflow participant to access the data (iPQ-View / Check,
Quality Assurance, Report Generator and Rewinder Control). This server is linked to the stations
via LAN. TCP is used as the communication protocol.
Windows XP / 7 32bit or 64bit, Windows Server 2008
Hard disk space needed depends on the amount of the protocols data
(250 GB recommended)
2 GB RAM
1 USB 2.0 port for dongle
1 Ethernet port 10/100 Mbit/s
NET Framework 4.0 Client Profile
Fixed IP address in the iPQ-Workflow network, corresponding subnet mask
Firewall: Enable incoming connections to ports 35876 and 35877 TCP / UDP for
DataDistributor.exe and OrigReelManager.exe
Firewall: The target addresses for the rules can be limited to the addresses of iPQ-View /
Check, Quality Assurance, Report Generator and Rewinder Control
Choose the Window "Add or Remove Programs" from the windows system control to uninstall the
software "MT 7.13 Build 4 for Windows".
For Rewinder Control installation please choose destination location on D. If you update an older
installation, maybe choose "C:\eltromat\DefectTracking" or something similar.
Basic Setup Instruction DefectTracking_V184.doc
erstellt: 13.10.2015 geprft: Datum freigegeben: Datum
Name Name Name
Installation instruction Page 11 of 23
iPQ-Workflow installation
If the application is installed on a iPQ-View / Check system, please choose the option "iPQ
Parallel", otherwise use "Maximized".
If the Data Server component will be installed, choose the number of iPQ-Check / iPQ-View to get
reel protocols from.
If there is the Rewind Navigator component selected, please choose the interface you want to use.
At default there will be the 24V interface with the signals SlowDown, FinalStop and Started
installed. See the interface documenation for more details.
Basic Setup Instruction DefectTracking_V184.doc
erstellt: 13.10.2015 geprft: Datum freigegeben: Datum
Name Name Name
Installation instruction Page 12 of 23
iPQ-Workflow installation
If the barcode reader Datalogic Gryphon should be installed, please check the checkbox. Please
see chapter 4.
Address of Data Server to connect. Only necessary, if Quality Assurance, Report Generator or
Rewinder Control will be installed. Insert the IP address and port of the Data Server to connect to.
Please check the cycle interval for refreshing the available reels from the Data Server.
In the device manager there are two new entries regarding the barcode scanner. Please note the
COM number (in this case COM5) , for setting the barcode scanner in the service menu of Quality
Assurance / Rewinder Control.
After this step the red dongle LED should light. In the device manager three USB controller should
be present.
Choose the application folder. If there is not enough memory on partition C on the Rewinder
Control, change the destination folder to D.
The setup is completed. Now all reports should open with Adobe Reader XI.
Necessary, if Data Server is installed. Insert the IP address and port of the iPQ-Check / iPQ-View
webservers where the reel protocols are available for download. Choose the directory where the
ReelFetch will copy the protocols to. Each iPQ-Check / iPQ-View gets his own subdirectory.
Please check the cycle interval for refreshing the available reels from iPQ-Check / iPQ-View to
transmit to the Data Server.
5. Run Application
5.1 Start the Application
Via shortcuts
The following users are created as default. Please change the passwords after installation.