INTEGRAL

Proven know-how and Thus, all functions, displays and


IP technology as standard. controls are retained in full in the
event of a fault.
The development of reliable fire alarm
systems is a Schrack Seconet tradition. Flexible interfaces.
Extensive investments in research and
development, as well as participation Integral IP control panels have
in international bodies and co-operation different interfaces and standardised
with technical universities, fire prevention protocols, such as BACnet, OPC, ESPA
bodies, fire brigade associations and or Modbus and therefore, are compatible
testing institutes ensure that the with other trades, such as for building
products are always on the cutting management systems.
edge of technology. All Integral IP
control panels have an IP interface and Reassuring
thus support the Internet Protocol. investment security.
With intelligent software applications,
the control panels can also be networked The highest possible degree of forward
independent of location and accessed and backward compatibility of the
remotely with a PC, smart phone or tablet. products is particularly important
to Schrack Seconet. A gradual
Intuitive and easy to use. modernisation of older fire alarm
systems can be easily and flexibly
The operating panel is the same for all performed, and are therefore always
Integral IP control panels: clearly arranged an investment in the future.
button layout and logical processes ensure
the necessary overview in stressful Made in Austria & Germany.
situations. The labelling of the keys and
the plain text information on the display Schrack Seconet places great emphasis
are available in more than 20 languages. on the high quality of all products.
The technologically advanced fire safety
Absolute reliability with systems are developed and produced in
full redundancy. Austria and in Germany and are already
in use worldwide.
Redundancy in hardware, software,
power supply and wiring ensures
maximum availability and failure safety.
FIRE ALARM IP technology
for all system sizes.

Fire alarm control panels

Extinguishing control panels

External operating & indicator panels


INTEGRAL

Integral IP Fire alarm


Integral IP MXF Integral IP CXF Integral IP BX control panels.
Structure modular, decentralised compact, decentralised Basic design
The Integral IP system family consists
optimised for the large systems and medium-sized systems, smaller buildings,
protection of buildings, for example, for example, such as of different control panels, equipment,
Industrial facilities, Residential Unoccupied housing types and components,
Office buildings, developments technical equipment, which can be perfectly combined and
Airports, Large supermarkets, Catering facilities, coordinated for each expansion stage and
Hospitals, Hotels, ... Underground car system size. All devices are compatible
Shopping centres, ... parks, ... with each other and work with the same
Hardware redundancy software and the same commissioning
Software redundancy tools. The detectors and modules of
the X-LINE can be connected to all
Loops per control panel max. 16 max. 4 max. 1
control panels and also the operating
Elements per control panel max. 4,000 max. 1,000 max. 250
interface is the same for all Integral IP
TCP/IP interface control panels.
Networkable via TCP/IP
Modernisation of
existing systems
Floor standing cabinet

Integral IP Extinguishing
Integral IP MXE Integral IP CXE control panels.
suitable and approved for CO2 high pressure and low pressure extinguishing
monitoring of systems with and without a danger to the safety In accordance with the standards,
of people the Integral IP MX and CX panels
Inert gas and argon extinguishing systems with can also be used as extinguishing system
and without a danger to the safety of people control panels (electronic control and
Spraying water & misting water extinguishing systems delay device according to EN 12094-1
Pre-action sprinkler systems and VdS 2496) or as a combined
Sprinkleranlagen
fire alarm / extinguishing system
Chemical extinguishing systems
control panel.
Controlling single-zone extinguishing systems
Controlling multi-zone extinguishing systems
Number of extinguishing zones 32 1
Additional parallel LED displays
Additional freely programmable
inputs and outputs

External operating &


indicator panels.

The operating interfaces of our systems


are continuously improved based on
customer needs and the requirements
of fire brigades and are available in more
than 20 languages. In addition to the
Integral IP control panels, we also offer
many variations and models of fire brigade
control panels (e.g. according to Austrian
Standard ON F 3031, DIN 14662,
SN 054002 etc.) and LED display panels.
FIRE ALARM Secure early fire detection
and alarm notification.

MTD 533X CMD 533X MTD 533X-S/SP MMD 130 Ex-i

Settings according to EN 54
MTD 533X MTD 533X-S/SP

Standard Typical applications CMD 533X MMD 130 Ex-i

EN 54-3 Sounders, e.g.


in hotel rooms, public buildings,
schools, etc.

EN 54-5 Heat detectors (conventional) where smoke


is expected to be a source of deceptive alarms
and where heat is not expected to be a source
of a deceptive alarm (e.g. smoking areas).

EN 54-7 Smoke detectors in standard applications for


rapid detection in the event of a fire with
formation of smoke (e.g. office buildings).

EN 54-26 CO sensor for purely technical alarms


without automatic alarm forwarding
to the fire brigade (e.g. garages).

EN 54-29 Combined smoke and heat detectors


where short-term disturbances such
as smoke, dust, insects and steam can
occur (e.g. workshops, warehouses).

EN 54-30 Combined CO and heat detectors for


particularly quick and certain heat detection
with CO assisted heat detection in areas where
both smoke and heat can occur as sources of
deceptive alarms (e.g. in industrial kitchens,
and where human life is endangered).
INTEGRAL

Integral CUBUS
Fire detector family.

Fire detectors with CUBUS detection Audible and visual


technology adjust actively, permanently, signalling devices.
automatically and dynamically to
atmospheric conditions. Not only the For acoustic and/or visual signalling Door holding magnet
individual factors of smoke, heat or of a fire, we offer a variety of such BX-MDH.
CO are measured in addition they devices in various colours and finishes
are always evaluated in the context for X-LINE as well as for conventional The magnetic door holder is used
of the relative changes in the other connection. All devices have an for automatic closing fire doors in the
relevant characteristics. If there is a EN 54 certification and/or VdS event of an alarm and is connected
change in the atmospheric conditions, approval. Schrack Seconet also offers directly to the Integral X-LINE.
then the sensitivity of the detector a complete line of flashing lights, Unlike conventional magnets, this is
is automatically adjusted. which corresponds to the European not energised around the clock, but
standard EN 54-23, in effect since rather keeps the door open completely
Manual call point. January 1, 2014. without energy consumption.

To manually actuate a fire alarm in Input & output modules. Short circuit isolator
accordance with EN 54-11, we offer in each element.
a variety of manual call points For connection of peripheral The short circuit isolators integrated
(type A or B according to EN 54-11) devices, we offer a variety of control into every X-LINE device as standard
in various designs and types of modules. Depending on the model, ensure planning security as well as the
protection. In addition, the call points potential-free contacts can be devices remaining fully functional
are available in other colours, as well interrogated, hazardous areas in the event of a short circuit,
as a stop button or as a triggering monitored, loads switched by wire break or sabotage.
device for manual actuation of an relays, or special fire alarm
extinguishing process (according systems can be integrated.
to EN 12094-3).
FIRE ALARM Special fire alarm systems
for extreme
conditions.
INTEGRAL

Aspirating smoke detector Duct smoke detector


ASD 535. LKM 593X.

Up to two independent aspirating For fire detection in ventilation


pipes, each up to 300 m in length systems or in places with high air
with up to 120 sampling points can velocity and strong smoke dilution.
be connected to the ASD 535. Thanks to early smoke detection, the
The software PipeFlow always LKM 593X prevents fires and smoke
guarantees a secure configuration from spreading within and through
according to EN 54-20, even with ventilation systems.
asymmetric routing. The ASD 535
is equally suitable for fire safety in Linear heat detector
high rooms and halls and for securing ADW 535.
areas that are difficult to access due
Harsh atmospheric conditions to structural or operational reasons. In extreme environmental conditions,
such as extreme air humidity and It also offers the ideal solution such as heat, humidity, dust and steam
soil load, high temperature or for facility monitoring around or gas development, the ADW 535
high altitudes challenges present electric cabinets, machinery for proves to be particularly reliable.
conventional fire detectors with manufacturing technology or Depending on the application, sensor
an almost impossible task. computer systems. tubes made of copper, stainless steel or
Schrack Seconet offers the special PTFE (Teflon) are used. On each device
fire alarm technology product Linear smoke detectors. two sensor tubes can be connected with
range for the right solution in up to 200 m in length as needed, even
every application, thereby In large industrial, public or historic in completely different atmospheric
guaranteeing security even under buildings, the maximum installation conditions. In addition to high
the most difficult conditions. height of conventional fire detectors temperature applications, such as
is often not enough. Here linear smoke foundries or drying ovens, areas with
detectors are used, which can be easily extreme temperature fluctuations
installed at high altitudes. If smoke from the garage to the industrial kitchen
enters the infrared beam between or dairies, recycling and painting
the transmitter and receiver, this facilities fall into the suitable areas
is characteristically subdued and of operation for the ADW 535.
an alarm is triggered.
LIST sensor cable.

Flame detectors for The addressable linear heat detector


hazardous areas. is characterised by precise detection,
high response speed, ease of
Flame detectors are used for the installation and commissioning.
detection of smokeless liquid and gas Various sensor distances, branches
fires, and smoke-intensive open fires in the sensor cable and individual
in hazardous areas, for example, in the temperature sensors provide
combustion of oil products, gases, wood the perfect solution for
or plastics occur (zones 1, 2, 21 and 22). every application.
Typical applications include large
industrial warehouses, aircraft hangars,
chemical plants, oil refineries,
machine rooms, power stations,
printing works, etc.
FIRE ALARM Intelligent IP applications
for more convenience
and safety.
INTEGRAL

SecoLOG IP.

Multi-user supporting, graphic


control system according to Austrian
Standard ON F 3003 for convenient
and easy display and operation of
fire alarm systems.

RemoteMESSAGE.

Multi-user supporting event


logging software (such as alarms,
faults, etc.) with active event
viewing and managing of one or
several fire alarm control panels.
With the operating panel Integral
VirtualMAP, the current state of
the fire alarm system is displayed
and operations can be performed
from a distance.

Integral ApplicationCenter IAC.

Service tool for programming


and configuring the complete
Integral IP system family.

IACmobile.

Multi-user capable Plug-and-Play


App with active event viewer for
displaying, operating and managing
one or more fire alarm control panels.

Integral MAIL.

Automatic emails from one or more


fire alarm control panels when
an event occurs.

S2Service.

The web-based service platform


provides the basis for worldwide
access to Integral IP control panels
www with a PC or mobile device.
The connection is encrypted and
meets the latest safety standards.
COMPETENCE

ON TOP

Subject to technical modifications!

SCHRACK SECONET AG
Headquarter Austria: A-1120 Vienna, Eibesbrunnergasse 18 Tel. +43 1 81157 office@schrack-seconet.com www.schrack-seconet.com
Branch offices Austria: Czech Rep. CZ-149 00 Prague 4 - jezd., S ttov 283 Tel. +420 2 74784422
A-6850 Dornbirn, Sebastianstrae 13a Tel. +43 5572 51199 Hungary HU-1119 Budapest, Fehrvri t 89 -95 Tel. +36 1 4644300
A-8055 Graz, Neuseiersberger Strae 157 Tel. +43 316 407676 India IN-122002 Gurgaon, 5th Floor, Technopolis, Sector-54 Tel. +91 124 4141501
A-6020 Innsbruck, Dr.-Franz-Werner-Strae 36 Tel. +43 512 365366 Poland PL-02-672 Warsaw, ul. Domaniewska 44a, bud. Platinium V Tel. +48 22 3300620
A-9020 Klagenfurt, Feldkirchner Strae 138 Tel. +43 463 429362 Romania RO-023961 Bucharest, Str. Mntuleasa nr. 15A et. 1, Sector 2 Tel. +40 372 756316
A-4060 Leonding-Hart, Kornstrae 16 Tel. +43 732 677900 Russia RU-129626 Moscow, Ul. Staroalexejevskaja 5 Tel. +7 495 5105015
A-5020 Salzburg, Vogelweiderstrae 44a Tel. +43 662 887122 Slovakia SK-83527 BratislavaRaca, Mudrochova 2 Tel. +421 2 44635595
Schrack Productions - B-PR-611EN - V 1.0 - 04.2015

Sweden SE-145 84 Norsborg, Botvid Business Center Tel. +46 8 6801860


Turkey TR-34722 Kadky-Istanbul, Kasap Ismail Sk. 5/5 Tel. +90 216 3455199

Sales partners in: ARM AZ BG BIH BY CH CY D DK E EST ET F FIN GE GR HR I IL KS KSA KWT KZ L LT LV MK N NL P PK RB RL SLO SRB TM UA UAE UZ

FIRE ALARM

S-ar putea să vă placă și