Documente Academic
Documente Profesional
Documente Cultură
Energy Independence
yeah!
WINNER
OTTI
INNOVATION CHARGE CONTROLLER
AWARD 2014
Highest efficiency
Input voltage range up to 200 V
for 12 / 24 / 48 V
First class integrated datalogger
for 20 years of data
Steca Tarom MPPT 6000-M Supports Li-Ion, NiCd and lead acid batteries
Solar charge controller
60 A, 12/24/48 V Two independent inputs and
maximum power point trackers (MPPT)
www.stecasolar.com
Steca Elektronik GmbH
Pico PV Kits p. 22 Energy Generation Kits p. 39 Solar Streetlight Kits p. 56
Monitoring and Lighting p. 32 Rural Electrification Kits p. 43 E-Mobility p. 62
Kits Energy Comfort Kits p. 35 Back Up Kits p. 48 Water Treatment p. 63
Caravan Kits p. 36 BOSS Kits p. 49 Water Desalination p. 65
Generators
Solar Charge Controllers p. 88 Hybrid Charge Controllers p. 108 Grid Inverters p. 128
Duo Solar Charge Controllers p. 99 Stand Alone Inverters p. 110 Pump Inverters p. 130
Solar Charge Controllers Stand Alone Battery Chargers p. 131
with MPPT p. 101 Inverter/Chargers p. 116 DC / DC Converters p. 133
Tools p. 302
celine.tandia@phaesun.com jessica.fleischer@phaesun.com
Tel. +49 (8331) 990 42 119 Tel. +49 (8331) 990 42 118
Alexis Skorupa
Regional Business Developer
West Africa
alexis.skorupa@phaesun.fr
Tel. +225 (22) 43 64 19
NE W
We proudly present...
The new Phaesun Online Platform is published
now. Get your log-in and take the chance to
benefit from our online distribution system:
Pico PV Kit
Module
Home use
Holiday houses
Garage lighting
Outdoor use
Mobile Recreational use
Phone Stick
Phone
Charger
Hub4
Junction Box
Ulitium
200 T-Lite
Module
Small DC systems
Telemetry use
Home use
Holiday houses
Garage lighting
Solar Charge Recreational use
Controller
DC
Loads
Battery
Module
Lighting of streets in regions
Street Lamp without reliable grid
Billboard lighting
Sports field lighting
Parking space lighting
Solar
Charge
Controller
Battery
Modules
AC and DC possible
Home use
Industrial use
Solar Charge
Controller Inverter
DC Loads
AC Load
Batteries
Recreation System
Module
Solar Duo- Marine use
Charge Recreational use
Controller Remote Control Caravan and c
amping
DC Load
Solar Battery
AA Accumulator
Charging
DC/DC
Converter
AC Load
Car Battery DC Load
Switches Switches
Solar
Batteries
Hybrid System
AC Load
Modules
PV and wind
turbine or diesel
Inverter/ generator
Charger DC and AC loads
possible
High reliability
DC Load
Solar Charge
Controller Water
Turbine
ind Controller
ator
Batteries
Back-up System
Grid
Batteries
Water Pumping
Modules
Water pumping for drinking
water and irrigation
No energy storage
Direct use of the power
Pump
Inverter
Pump
Water Purification
Module
Save drinking water without
use of chemicals
Cleaning and desinfection by
using sunlight
Water Purification
System
Battery
Water Desalination
Desalination of
Solar
seawater or from
modules salty wells
Use mainly in
coastal areas
Pretreatment
Chemical free, only
and with renewable
Desalination
Pump from Unit energy sources
saltwater
sources
Battery
Clean Water
Storage
Telecommunication System
Modules
Use in rural areas
without grid
Powering of
telecommunication
GSM and BTS
Solar Charge
Controller
Telecommunication
Batteries System
Cathodic Protection
Modules Protection of
valuable buried
pipelines from cor-
rosion
CPCU PV system injects
Solar Charge
Controller the required current
into the pipeline
Batteries
Pipe Grounded
Cathode Anode
Off-Grid Connect
Modules
Covering self
consumption
Grid is used as
back-up
Reduces energy
cost
AC Load
Inverter/Charger
Grid
Batteries
yeah!
Solar
s
system e
o r m o bil
f
d,
PV, win ro use
id
hyd
small r Off-gr
powe power
supply
solar
- Rural
Street i-
g
lightin electrif
Solar cation
g
pumpin
s
system
Product News
NEW!
Monitoring and
Exterior Lighting Kits p. 32
Caravan Kits p. 36
Back Up Kits p. 48
BOSS Kits p. 49
E-Mobility p. 62
Water Treatment p. 63
Water Desalination p. 65
21
Kits
Kits Pico PV Kits
Pico PV Kits
Blow Up Disco
NEW!
Blow Up Colour
Features
Integrated LEDs and battery
Magnetic switch, no moving parts
For functional and decorative use
Handmade portable glass lantern
Glass jar 100 % recyclable
Features
50 lumen brightness solar LED light
All-in-one re-chargeable solar light
Ultra cost-efficient design
Comfortable 2 x light mode slider
User-friendly multi-flex design
Solid engineering & durable materials
Accessories, p. 232
Features
300 lumen brightness solar LED light
Mobile phone charging
Comfortable 5 x light mode slider
Durable long lifetime solar PV panel
Dust & water protected Accessories, p. 232
Accessories, p. 232
Niwa's mid-range starter system of Modular- lights. Lamps can be individually dimmed
Solar-Systems (MSS). Each lamp offers (3 x light modes for each lamp) according to
impressive 100 Lumen brightness which brings the situation of use, room size and sunshine
total system brightness to 200 lumen. They duration at a particular day. Dimming takes
are water and dust proof and can also be place conveniently at a wall switch for
installed as outdoor lamps serving as security each lamp.
NEW JouLite
JouLite is a multifunctional lamp. Torch, mo-
bile phone charger and table lamp: all in one!
The lamp can be charged with a 5 V solar
module or a USB cable.
Features:
Light output of 150 lumen
Innovative product design: multifunctional, JouLite Kit 1
robust and water proof
Dimmable light: Up to 60 h of light with a
fully charged battery
Charging hub for mobile phones
JouLite 150
Phone Stick
Hub4 Hub4
Junction Box Junction Box
Joule Stick
Phone Stick T-lite
Ulitium 200
Wall Dock JouLite
Brand new
Joulite satisfies all energy needs in products will be
just one compact kit presented at the
Off-Grid Experts
Workshop 2015.
This solar lamp and charger kit contains Special features:
See page 15.
one or two robust lamps with high Light output of
efficient LEDs and integrated Lithium- 150 lumen
Ion storage, the corresponding solar Charging hub for mobile phones
module, charging cables to connect Innovative product design:
USB devices and a lamp holder to use a multifunctional, robust and
standard drinking bottle as lamp stand. water proof
Dimmable light: up to 60 h of light
with a fully charged battery
T-lite
The T-lite is an ideal illumination kit and can
be used whether as a ceiling lamp, table lamp,
or as a manageable torch with eight LEDs
it reaches a considerably high illumination
level of 180 lumen. Highly efficient integrated
lithium cobalt batteries provide a long
luminous period. In contrast to the Ulitium
lamp, its counterpart, the T-lite is equipped
with a simple touch button and included
dimming function. T-lite is available as
complete kit with corresponding solar module
or as single lamp. The simple Plug-and Play-
technology provides highest flexibility.
Ulitium
These PicoPV kits are the low-cost and
maintenance-free alternative for standard
Solar Home Systems. The popular Ulitium
Kits include one to four high efficient LED
lamps with integrated lithium cobalt battery
providing a light output of 240 lumen,
the perfectly fitting solar module and a
distribution box. It is easy to install and can be
easily expanded according to the needs of the
user with more lamps, cell phone charger or
JouleStick. All you need for lighting your home
in just one box! Accessories, p. 236 and following
Ulitium-lamp: With integrated LiCoO2 energy Sundaya Charging Station, p. 50
storage. Sundaya solar modules, p. 235
Accumulator Packs, p. 31
Monitoring and
Exterior Lighting Kits
Info Signs
Quality stainless steel design and slightly con-
vex lighting surface made of UV resistant plas-
tic material. The plastic lighting surface can be
taken out for the labelling with adhesive film
or printing. While the installed accumulators
are charged by means of the solar modules
during the day, the information sign is acti-
vated automatically at night. Delivery ready for Support Structure,
Made in
operation, accumulators included. p. 238 Europe
Sign Illumination
Appropriate for the illumination of existing
promotional signs, company nameplates, or
information signs. This complete package is
available in three different lengths.
Made in
Europe
Caravan Kits
Pcs. Article
Solar Rise Three 2.0
2 Solar module 50 W | 12 VDC
1 Wind generator 160 W | 12 VDC
1 Charge controller 10 A | 12 VDC
1 AGM Battery Sun Store 150 Ah | 12 VDC
1 Installation cable
1 Battery cable 15 A fuse
Article No. 600079
Autonomy days
[kWh/m,day]
[Ah@48 V]
Requested
Irradiance
capacity
[kWh]
1 6 11,51 900 3
Every kit available without battery: 2 5 9,59 900 4
Solar Rise X Four Art.No. 600251
Solar Rise X Five Art.No. 600252 3 4 7,67 900 5
Please contact our Sales Team (p. 4). 4 3 5,75 900 6
Pcs. Article
Solar Rise Five
24 Solar modules 250 W
1 Solar connection box
1 Outback Flexpower Two
6 KVA | 48 VDC | 230 VAC
24 Batteries 6 OPzV 1500 | 2 VDC
1 Battery rack
1 Solar cable
1 Installation cable
1 Installation material
Article No. 600250
Autonomy days
[kWh/m,day]
[Ah@48 V]
Requested
Irradiance
capacity
[kWh]
1 6 23,10 1800 3
2 5 19,25 1800 4
Support Structures,
p. 239 and following 3 4 15,40 1800 5
4 3 11,55 1800 6
Modules
... AC Load
Connection
box
Generators
Inverter/Charger
MPPT Charge Controller
Grid
...
Batteries
Phaesun offer easy-to-install turnkey solutions If you are interested in kits with a system
for either lighting, ventilation, cooling and/ voltage of 12 VDC, please do not hesitate
or freezing. The kits are available in different to contact our sales team.
configurations according to the different Have a look on the irradiation maps on the
irradiation groups. The kits have a system back cover to find the perfectly fitting kit
voltage of 24 VDC. for your specific location.
Components:
2 Solar modules
2 LED tubes
2 batteries
Charge controller
Cabling Find your irradiation group on the
Mounting structure map on the back cover page
Components:
2 solar modules
1 ceiling fan
2 batteries
Charge controller
Cabling Find your irradiation group on the
Mounting structure map on the back cover page
KIT WITH
Rural Electrification Kit Be Cool and Ice Age STECA
FRIDGE
The Phaesun Kits are the best solution for PF240 ON
reliable cooling and freezing needs far from REQUEST!
the electricity grid. These kits include the
solar fridge Steca PF 166, that can be used
for cooling or freezing, all equipment for
charging, installation and installation manual.
The Refrigeration Kits are best suitable for the
use in health posts, grocery stores etc.
Components:
Solar modules
Solar Fridge/Freezer Steca PF 166
Batteries
Charge controller
Cabling
Mounting structure
Components:
Solar modules
Ceiling fans
Solar Fridge Steca PF 166
LED tubes
Batteries
Charge controller
Cabling Find your irradiation group on the
Mounting structure map on the back cover page
WHO Standard!
Back Up Kits
Components:
1 inverter/charger
1 battery
1 DC circuit breaker
1 spelsberg AK05
2 cable gland M20
2 cable gland locknut M20
Cable 3 m
2 uninsulated wire end 16 mm2
4 ring terminal 16 mm2
Double pole bus bar for triple pole
circuit breaker
BOSS Kits
Business Opportunities with Solar Systems
BOSS-Concept Off-Grid solar power systems The Phaesun technical team develops
can be an important factor to support rural innovative solutions together with component
development in areas that are not connected manufacturers and partners in the target
to the electricity grid. The Phaesun BOSS- countries. The systems are well adjusted to
solutions target specifically the commercial local needs, designed with high quality energy
sector in non-electrified areas. BOSS stand for efficient loads which makes them robust with
Business Opportunities with Solar Systems. little maintenance needs.
BOSS Charging Services Almost everywhere although the grid is far away. These BOSS-
people are used to the utilisation of electronic systems offer charging services and can be
devices. Cell phones, batteries for illumination either used in shops or as mobile solutions e.g.
purposes and DVD players are in common use for services offered at markets etc.
BOSS Solutions for Cooling and to run electric light, operate fridges and
Entertainment Solar systems can increase entertainment devices such as TVs or music
the service quality of existing shops, bars, boxes with solar power can improve service
restaurants etc. in rural areas. The opportunity quality and service portfolio.
20 30 55
Desert Central Africa, South-West Africa, North-
IG1 West Peru East Africa, Central Andes
Desert and Subtropical Southern and Northern Af-
IG2 Africa, South-East Africa, rica, Middle East, Northern
Central Brazil to Honduras Argentina, Southern Brazil
Equatorial Africa South-East Africa Coastal Southern Europe, Middle
IG3 Line, Southern Brazil Coas- East (Northern Part), Sou-
tal Line thern Argentina
Parts of Southern and
IG4 Middle Europe, Patagonia
Street Light Kit 20 W 20W-Kit is ideal for lighting of foot paths and
cycle tracks, small roads and outside illumination at houses and garages.
W-Light 20 W LED Lamp | 12/24 V | 10 LEDs | 2030 lm
20 W 20 30 55
IG1 600094 600093
80 W solar module, 80 W solar module,
120 Ah battery 120 Ah battery
600094 600093
IG2
80 W solar module, 80 W solar module,
120 Ah battery 120 Ah battery
600095 600117 600118
IG3 100 W solar module, 100 W solar module, 100 W solar module,
120 Ah battery 120 Ah battery 120 Ah battery
600096
IG4 120 W solar module,
120 Ah battery
Street Light Kit 30 W Street Light Kits with the W-light lamp 30 give bright
light for public roads, parks and bigger parking areas or sports parks.
W-Light 30 W LED Lamp |12/24 V |15 LEDs | 2770 lm
30 W 20 30 55
IG1 600123 600101
90 W solar module, 90 W solar module,
2 x 100 Ah battery 2 x 100 Ah battery
600102 600124
IG2
100 W solar module, 100 W solar module,
2 x 100 Ah battery 2 x 100 Ah battery
600103 600125 600126
IG3 135 W solar module, 135 W solar module, 135 W solar module,
2 x 100 Ah battery 2 x 100 Ah battery 2 x 100 Ah battery
600104
IG4 195 W solar module,
2 x 100 Ah battery
Components:
High efficiency LEDs
Lamp bracket
Sealed battery
Top of pole mount battery box
MPPT solar charge controller with
time program function
Module
Made in
Mounting structure Europe
The Park Lighting System is also available with 18 W-lamps (1690 Lm).
E-Mobility
NEW X-Robot
The X-ROBOT S2 is the free balancing solution
for urban transportation of the future.
Equipped with a seat, intuitive steering and
integrated illumination, this model outrivals
any existing personal transporter. Due to
the removable platform, the S2 can easily
be dismounted and stored in the car. Its to
the last detail thought through concept as
well as the futuristic design along with long
life qualities due to lithium-ion batteries
distinguish this model even further. With a
range of approximately 40km (depending on
terrain and weight of the driver) as well as
1000 guaranteed loading cycles, a total range
of 40.000 km can be achieved.
Water Treatment
THE MAGAZINE for Renewable Energies ISSN 1861-2741 74714 www.sunwindenergy.com 12.00 International issue
12/2013
HAUSTECHNIK FR STROM
UND WRME
11+12/2013
Energieverbrauch
Speichern,
steuern,
PHOTOVOLTAICS
PHOTOVOLTAI
PHOTOVOLTAICS Planung
Solarpark Letschin
sparen
World maps
Entwicklung
Montage
Betriebsberwachung
of the PV industry
Speicherysteme auf dem Vormarsch
Phone: + 49 2251 1482-0
7h95KHLQODQG E-Mail: info@fs-sun.de WEL
WELTKARTE DER SOLARTHERMIE
WELTKARTE
'
4BTACQK*haifae+[B\C
www.fs-sun.de
Turbulente Zeiten
SOLAR THERMAL PHOTOVOLTAICS
PHOTOVOLTAI
PHOTOVOLTAICS WIND ENERGY
World map: No
No PV park without Rotor blades: From
The seven year itch maintenance passive to active
Powered by
Offshore
www.offshore-wind-industry.com Issue 2013 No. 02 24
WeserWind GmbH
... stands for innovative solutions in the field of
wind energy and, through such solutions, we
service a future-oriented market in Germany.
Offshore
Issue No. 03 24
standards. WeserWind is playing an important role
in the construction of numerous wind farms in the
North and Baltic Seas and is the first company in
the world to produce foundation structures serially
to a fixed schedule.
WIND INDUSTRY
Our portfolio of services also includes the building
of offshore substations as well as
The international trade
Full
the erection of complete wind metmasts.
Quietly powerful
The MHU 3500S system enables the safe and silent installation of the next generation
of monopiles.
SYNERGY FOR ENERGY
THATS OUR MOTTO.
commitment magazine for the
With the worlds most powerful hydraulic hammer, MENCK opens a new dimension of
pile-driving activities and is prepared for the future of offshore wind power. for maximum OFFSHORE WIND INDUSTRY
availability
We have reduced the noise emissions during pile-driving with an optimised mass ratio
between hammer and pile.
Why not contact us?
Find out more at www.menck.com/quietly Together we will find new ways!
www.o shore-wind-industry.com
Service & maintenance in offshore wind farms demands
Full steam
info@weserwind.de skilled hands and personal commitment. Solid HSE
www.weserwind.de concepts and quality equipment ensure maximum safety.
Water Desalination
with Mrk Desalin Smart Unit
Technical Data
100 & 200 l/h drinking water capacity (WHO Quality)
12+ hours operation time
Operation without chemicals
100 % renewable energy supply through solar and/or wind
Dimensions: 4,50 x 2,90 x 1,80 m
Wind Generators p. 78
Micro Hydropower p. 83
67
Kits
Generators Framed Modules
Generators
Generators
Solar Modules Sun Peak SPR
The Sun Peak SPR modules feature back-
contact mono crystalline cells with a unique
structure that yields conversation efficiencies
of up to 20 %. They are aesthetically pleasing
and ideal for Off-Grid applications.
Features:
Photovoltaic modules made with unique
back connected cells
Cells with high conversion efficiency
up to 20 %
Manufactured in ISO9001 certified factory
Designed to charge 12 to 48 VDC batteries
for Off-Grid remote systems
Made with high quality materials which
qualifies high reliability of modules
Reduced weight and surface
Single packed
Support Structures,
p. 239 and following
Generators
Solarworld Crystalline Solar Modules
The cells of the modules are situated behind a
protective glazing made of hardened glass and
are embedded in transparent EVA. The rear of the
modules is sealed with a high-grade laminate. The
module frame and the enclosed glass are securely
attached to one another by universally applied
silicon guaranteeing module stability above
average. The load capacity of the front of the unit
of up to 5,4 kN/m2, which meets the IEC 61215
standard, confirms the suitability of the modules
to withstand large build-ups of snow and ice. The
cabling of our Off-Grid modules is simple and safe
thanks to the splash-proof connection socket.
High-quality, spring-type clamps enable quick and
secure wiring without special tools.
0DGHLQ
More Accessories and Support Structures, p. 239 and following *HUPDQ\
Generators
Istar Polycrystalline Solar Modules
The photovoltaic modules are produced with
the most innovative technologies of isotropic
texturization and antireflecting coating. These
modules are made of solar cells encapsulated
between sheets of ethylene vinyl acetate
(EVA), using only guaranteed and certified
materials. They are highly transparent,
antishock, tempered glass which protects
the modules against mechanical and climatic
effects, such as hail, ice etc. They guarantee
very good module performances, power and
working conditions even if in lower sunlight
levels worldwide. The modules are equipped
with a special waterproof junction box Tyco
Made in
with protection class IP55. Europe
Sunware SW Modules
Highly efficient, crystalline solar cells provide optimal
power input of your island system on the water and
on land. The Sunware modules are extremely flat, only
5 mm and have no sharp corners or components. In
addition to the use on sailing yachts and motorboats,
these modules are also ideal for vehicle roofs of vans
and trucks because of their flatness.
Generators
Article Dimensions [l x w x h] Weight Article No.
Mono Crystalline Solar Modules Sunware TX | 24 VDC | 80 cells
Solar Module SW 3265 48WP 838 x 499 x 5 mm 5,5 kg 310065
48 W | 24 VDC
Solar Module SW 3266 70WP 891 x 638 x 5 mm 7,0 kg 310066
70 W | 24 VDC
Solar Module Sunware TX | poly crystalline
Solar Module TX 12039 38 Wp 873 x 461 x 5 mm 2,0 kg 310152
38 W | 12 V | 36 cells | textile edge
Solar Module TX 12052 50 Wp 1106 x 431 x 5 mm 2,0 kg 310153
50 W | 12 V | 36 cells | textile edge
Solar Module TX 22039 76 Wp 873 x 826 x 5 mm 4,2 kg 310154
76 W | 12 V | 72 cells | textile edge
Solar Module TX 22052 100 Wp 1106 x 400 x 5 mm 4,2 kg 310155
100 W | 12 V | 72 cells | textile edge
Solar Module TX 42039 152 Wp 929 x 1590 x 5 mm 8,6 kg 310156
152 W | 12 V | 144 cells | textile edge
Solar Module Sunware TX 42052 200Wp 1164 x 1590 x 5 mm 8,6 kg 310157
200 W | 12 V | 144 cells | textile edge
ApolloFLEX Mono
These solar modules are qualified for the use in
most various environments, even with saltwater.
The modules are maintenance free, weather-
resistant with a long durability. One of the most
important technical features of the ApolloFLEX
MonoTM modules are the high efficient back
contact solar cells which are the most efficient
solar cells available on the market at the moment.
They combine a high charging voltage at high 0DGHLQ
temperatures and an efficient charging capacity. *HUPDQ\
Generators
Flexible Solar Modules
Wind Generators
Generators
Silentwind Wind Generators
The Silentwind 400 models with the silent
whisper blades are perfect for Off-Grid use also in
combination with solar.
Features:
Higher efficiency due to earlier charging start-up
Faster wind tracking and stable operating
performance due to an enlarged wind-deflector
Additional body bearing for a more precise
guidance of the wind generator and smoother
operating
Reinforced mast support for higher safety
reserves under strong winds
Made in
With hand laminated, UV-resistant carbon Europe
fiber (CFRP)-rotor blades: successfully tested
in the wind tunnel at hurricane wind-speed
of 122 km/h, creating 5480 rpm with sonic
velocity at the blade-tips Hybrid Charge Controllers, p. 108
Generators
AIR 40 Land Wind Generators
AIR 40 is the optimal choice for Off-Grid
remote homes, caravans, water pumping and
lighting. Designed for energy requirements in
low to moderate wind locations, AIR 40 is the
ideal solution where minimal sound emission
is critical.
Specifications AIR 40
Start up wind speed: 3,5 m/s
Energy approx. 40 kWh/month
at 5,8 m/s
Generators
Micro Hydropower
AC Load
Modules
Inverter/
Charger
DC Load
Solar Charge
Controller Water
Turbine
Wind Controller
nerator
Batteries
Electronics
Solar Charge Controllers p. 88
DC / DC Converters p. 133
85
Kits
Generators
Electronics
r
Stude
tring,
... or dual MPPT in parallel VarioS
03
up to 600 V (Voc) page 1
or in serie MPPT
up to 900 V (Voc)
Generators
Electronics
Solarix PRS Solar Charge Controllers
The simplicity and high performance of the Steca
Solarix PRS solar charge controller make it particularly
attractive. Here, Stecas latest algorithms are employed
in order to guarantee optimal battery maintenance.
The Solarix PRS charge controllers are equipped
with an electronic fuse, thus ensuring the optimal
protection. They operate on the serial principle, and
separate the solar module from the battery in order to
protect it against overcharging. The Solarix PRS charge Accessories,
p. 249 and following
controllers are universal charge controllers: they can be
used with lead-acid batteries or gel batteries without Programmable with RC100,
the need for complex configuration settings. For larger p. 252
projects, the charge controllers can also be equipped
with special functions: night light function, selectable
charging plateau and deep discharge protection
voltages. The Steca Solarix PRS works on PWM as a low 0DGHLQ
loss series controller. *HUPDQ\
Generators
Tarom Solar Charge Controllers
Numerous clever functions allow the user
to adjust the controller to the particular
features of the system in question. Thanks
Electronics
to the significantly improved state of charge
determination, the system is optimally
controlled and the batteries are protected.
A graphic display informs about system data
and enables configuration and adjustment of
Tarom 4545
the controller to the specific requirements of
the individual system. The Steca Tarom charge
controller is the best choice for system sizes freely configured as a timer, a night light
of up to 2,700 Wp at three voltage levels function, to start generators or as surplus
(12 VDC, 24 VDC, 48 VDC). The integrated management.
data logger stores all important system
data which can be read via an open Steca
Accessories, p. 249 and following
UART interface. As an option, an external
temperature sensor can also be connected.
0DGHLQ
Two additional switching contacts can be *HUPDQ\
Generators
Electronics
SunSaver ProStar
This charge controller is This mid-range controller with
equipped with full elec- extensive electronic protec-
tronics protection, 4-stage tions is perfectly suited for TriStar
PWM battery charging and professional & consumer ap- This 3-function controller
self-diagnostics. It is the ideal plications. It is equipped with provides reliable solar battery
controller for oil & gas, tele- temperature compensation charging, load control or di-
communications, instrumen- and enables longer battery life version regulation. It operates
tation, marine & boating and & increased battery capacity in one of these modes at a
solar home systems. Designed through constant voltage time and two or more control-
for harsh environments & easy PWM series regulation, using lers may be used to provide
use/install. 4-stage charging. multiple functions. It also
supports parallel operation
for larger solar arrays of up to
300 Amps or more as well as
Accessories, p. 253 4-stage charging to increase
battery capacity.
SunSaver ProStar
Class I, Division 2, Groups A-D 15 or 30 amps at 12 to 24 volts 40 C
certification to +60 C ambient operating temp.
TriStar MPPT
30, 45 & 60 amps at
up to 150 Voc 40 C
SunSaver MPPT
to +45 C ambient
15 amps at up to 75 Voc 40 C to
operating temp.
+60 C ambient operating temp.
Generators
Phocos Solar Charge Controllers
Electronics
Eco 10 CMLup CMLsolid
The Eco solar charge The CMLup is equipped The controller is equipped
controller is designed for with a USB port for charging with a number of features
small solar systems requiring mobile phones and status such as an aluminum
low-battery disconnect. The display, acoustic alarm housing, USB port, battery
Eco series is fully electronically and safety functions. The status display, acoustic
protected and offers an LED temperature-compensated, alarm, electronic protection
display showing charge and four-stage PWM charging against reverse and wrong
load status. algorithm is adjustable for polarity. The temperature-
sealed and vented lead-acid compensated, four-stage
batteries. PWM charging algorithm
is adjustable for sealed and
Phocos Accessories, p. 258 vented lead-acid batteries.
T
s MPP
Phoco g e
C h a r
Solar
t r o ll ers,
Con
p. 106
Generators
Duo Solar Charge Controllers
Electronics
NEW Duo Solar Charge Controller
Smart Duet
The Phaesun duo-solar charge controller Smart
Duet has especially been developed for the
charging of two batteries which makes it best
suitable for applications in mobile homes to
charge both living room and starter battery
independently with the solar module.
Special features:
USB-port in the charge controller and 0DGHLQ
*HUPDQ\
remote display
Extensive protection functions
Current status of the two batteries clearly
displayed The Smart Duet charge controller is available
Integrated data logger and energy meter in as a single item or in a set with a practical
the remote display remote display Smart Duet, so all functions
Parameter settings can be also displayed and programmed
Graphic remote LCD-display can be independently of the installation site of the
connected charge controller via the graphical display.
NEW
Generators
Electronics
Twice as good!
Solar Module
o
un Du
Mobile Phone Phaes g e
C h a r
Solar
Remote n t r o ller,
Display Co
12 V Load
Duo Solar
p. 99
Charge Controller
Tablet Computer
Car
Battery
Living Space
Battery
Generators
with MPPT
Electronics
Solarix MPPT Charge Controllers
This MPPT charge controller optimally charges
batteries when using PV-modules of grid-
connected systems. It is a simple and reliable
device providing maximum flexibility in module
configuration. It is also possible to use thin
film modules with this device. The latest
technology guarantees professional battery care
combined with modern design and outstanding
protection features. Programmable via PA Accessories, p. 249 and following
RC100. The Steca Solarix MPPT works on PWM 0DGHLQ
as a low loss series controller. *HUPDQ\
Generators
VarioString
Simple/Dual MPPT Solar Charge Controller
This Serie, thanks to its high voltage PV
inputs reduces the Balance of Systems costs
Electronics
when it comes to larger systems. It eliminates
expensive wiring for parallel strings, saving
wires, junction boxes, fuses, space, time, etc.
Safe, simple and trouble free connection
with SUNCLIX
Simplified safety rules by full isolation
between PV and battery and between
MPPT inputs
Any grounding strategy applicable thanks
to isolated MPPT inputs. Grounding system
fault detection.
High conversion effciency > 98 %
4,2/2 x 3,5 kW per units and up to 15 units
in parallel BTS-01 Temperature Sensor, p. 256
Clear 9 LEDS status on current monitor RCC-02 Remote, p. 256
Generators
TriStar MPPT Charge Controllers
The TriStar MPPT controllers, with the patented
TrakStar advanced control algorithm technology,
harvest the maximum power from a solar array's
Electronics
peak power point, delivering the industry's highest
peak efficiency of 99 %. Perfect for a variety of
solar-electric power installations, including caravan
& marine, residential, highway telemetry, outdoor
lighting and industrial automation & control systems.
Features
Maximizes energy harvest
Extremely high reliability
Low self-consumption
Extensive networking, metering and data logging
and communication capabilities
Certified to IEC 62093
Low battery protection
Remote temperature sensor included Accessories, p. 253
Generators
Hybrid Charge Controllers
Electronics
Modules
Wind
Generator
Batteries
Generators
Modules Data Master Data Slave Data Slave Data Slave
Inverter
Solarix PI 550
Electronics
Charge Master
Controller Slave 1 Slave 2
Slave 3
Power Tarom Connection Box
PAx4
Battery
Generators
Article Dimensions [l x w x h] Weight Article No.
Inverter Lines AJ 1000 / AJ 1300
AJ 1000-12 142 x 428 x 84 mm 8,5 kg 101310
Electronics
800 VA | 12 VDC | 230 VAC | 50 Hz | IP30
AJ 1000-12-S 142 x 428 x 84 mm 8,5 kg 101311
800 VA | 12 VDC |230 VAC | 50 Hz | IP30 | 25 A solar charge controller
AJ 1300-24 142 x 428 x 84 mm 8,5 kg 101312
1000 VA | 24 VDC | 230 VAC | 50 Hz | IP30
AJ 1300-24-S 142 x 428 x 84 mm 8,5 kg 101313
1000 VA | 24 VDC | 230 VAC | 50 Hz | IP30 | 25 A solar charge controller
Inverter Lines AJ 2100 / AJ 2400
AJ 2100-12 273 x 399 x 117 mm 19,0 kg 101314
2000 VA | 12 VDC | 230 VAC | 50 Hz | IP30
AJ 2100-12-S 273 x 399 x 117 mm 19,0 kg 101315
2000 VA | 12 VDC | 230 VAC | 50 Hz | IP30 | 30 A solar charge controller
AJ 2400-24 273 x 399 x 117 mm 18,0 kg 101316
2000 VA | 24 VDC | 230 VAC | 50 Hz | IP30
AJ 2400-24-S 273 x 399 x 117 mm 18,0 kg 101317
2000 VA | 24 VDC | 230 VAC | 50 Hz | IP30 | 30 A solar charge controller
AC loads
AC loads
DC loads
Generators
NEW Inverters Phocos SI
This new inverter series converts DC energy
from solar modules into clean, stable AC
power that is ideal for power demanding
Electronics
appliances. Phocos inverters are designed
for high efficiency: Integrated advanced
microprocessor technology combined with
pure sine wave output makes them the perfect
choice for use with high-end electronics
and electrical equipment. Thanks to their
low weight and long lifespan, the SI series
inverters are also ideal for mobile and outdoor
applications. Overload, short circuit, over/
under voltage and overheating protection are
standard on all models. All Si-inverters are able
Phocos Remonte Control, page 258
to control remotly with optional SI-RSW.
Stand Alone
Generators
Inverter/Chargers
Electronics
XTS XTM
XTH
Generators
Article Dimensions [l x w x h] Weight Article No.
Inverter/Charger Line XTS
XTS 900-12 110 x 210 x 310 mm 8,2 kg 320070
Electronics
900 VA | 12 VDC | 230 VAC | 50 Hz | IP54 | BC 0 35 A
XTS 1200-24 110 x 210 x 310 mm 9,0 kg 320071
1200 VA | 24 VDC | 230 VAC | 50 Hz | IP54 | BC 0 20 A
XTS 1400-48 110 x 210 x 310 mm 9,3 kg 320072
1400 VA | 48 VDC | 230 VAC | 50 Hz | IP54 | BC 0 10 A
Inverter/Charger Line XTM
XTM 1500-12 133 x 322 x 466 mm 15,0 kg 303040
1500 VA | 12 VDC | 230 VAC | 50 Hz | BC 0 70 A
XTM 2000-12 133 x 322 x 466 mm 18,5 kg 106001
2000 VA | 12 VDC | 230 VAC | 50 Hz | BC 0 100 A
XTM 2400-24 133 x 322 x 466 mm 16,2 kg 303043
2000 VA | 24 VDC | 230 VAC | 50 Hz | BC 0 55 A
XTM 2600-48 133 x 322 x 466 mm 16,2 kg 303045
2000 VA | 48 VDC | 230 VAC | 50 Hz | BC 0 30 A
XTM 3500-24 133 x 322 x 466 mm 21,2 kg 106002
3000 VA | 24 VDC | 230 VAC | 50 Hz | BC 0 90 A
XTM 4000-48 133 x 322 x 466 mm 22,9 kg 106003
3500 VA | 48 VDC | 230 VAC | 50 Hz | BC 0 50 A
Inverter/Charger Line XTH
XTH 3000-12 230 x 300 x 500 mm 34,0 kg 106381
2500 VA | 12 VDC | 230 VAC | 50 Hz | IP20 | BC 0 160 A
XTH 5000-24 230 x 300 x 500 mm 40,0 kg 106382
4500 VA | 24 VDC | 230 VAC | 50 Hz | IP20 | BC 0 140 A
XTH 6000-48 230 x 300 x 500 mm 42,0 kg 106383
5000 VA | 48 VDC | 230 VAC | 50 Hz | IP20 | BC 0 100 A
XTH 8000-48 230 x 300 x 500 mm 46,0 kg 106384
7000 VA | 48 VDC | 230 VAC | 50 Hz | IP20 | BC 0 120 A
local/remote communication
Generator AC loads
Stay connected
with the System
The Xtender/Vario systems can be enti- provided the site has internet access via
rely and remotely controlled by mobile a local network; or by Xcom-GSM, if
phone with the Xcom-SMS that requires there the site has access to the mobile
a basic GSM (2G) coverage. The phone network. Our server will provide
information exchange change of pa- secure and full access parameters,
rameters, data request, alarms or report real time data, data log, configuration
sending, etc. is then done by sending of alarms by SMS or E-Mail, etc. to all
a simple SMS, secured by password. In sites with an Xcom-LAN or Xcom-GSM
addition, total control of the system is installed, and by means of any device
also possible via internet on our secured with an internet browser: smartphone,
server. The connection with the internet PC or tablet.
is carried out either by the Xcom-LAN,
r
Stude ,
c c e s sories
A
and
p. 272
o w ing
foll
See
XTM 116
page
re
for mo
rm ation.
info
XTS
XPC
-S means solar charge controller integrated.
Article Dimensions [l x w x h] Weight Article No.
Inverter/Charger Line XPC
XPC 1400-12 410 x 215 x 124 mm 11,7 kg 101375
1100 VA | 12 VDC | 230 VAC | 50 Hz | IP20 | BC 0 45 A
XPC 2200-24 410 x 215 x 124 mm 12,6 kg 101376
1600 VA | 24 VDC | 230 VAC | 50 Hz | IP20 | BC 0 37 A
XPC 2200-48 410 x 215 x 124 mm 12,6 kg 101377
1600 VA | 48 VDC | 230 VAC | 50 Hz | IP20 | BC 0 20 A
XPC 1400-12-S 410 x 215 x 124 mm 11,7 kg 106319
1100 VA | 12 VDC | 230 VAC | 50 Hz | IP20 | BC 0 45 A / 30 A SCC
XPC 2200-24-S 410 x 215 x 124 mm 12,6 kg 106320
1600 VA | 24 VDC | 230 VAC | 50 Hz | IP20 | BC 0 37 A / 30 A SCC
XPC 2200-48-S 410 x 215 x 124 mm 12,6 kg 106321
1600 VA | 48 VDC | 230 VAC | 50 Hz | IP20 | BC 0 20 A / 20 A SCC
Generator
AC loads
Generators
Inverter/Chargers Symphony Combi
Symphony Combi is an inverter/charger
combination providing true sine-wave inverter,
Electronics
battery charging and AC transfer switch in
together. It can be connected to either grid or
generator to compose power system for the
most demanding mobile, Off-Grid and power
SYC600
backup application.
Features:
Inverter, charger and transfer switch
Pure sinewave for all appliances
Starting your fridge or aircon
Saving battery power
Autosense of mains-/generator power
Protects your batteries and appliances
Optional COM and remote module SYC2000
FLEXpower ONE TM
Systems
This system
accommodates
Electronics
Generators
FX Inverter/Charger Series
FX series is a modular building block sine wave inverter/
charger that can be used for both small and large power
systems. Each FX inverter/charger is a complete power
Electronics
conversion system DC to AC inverter, battery charger and
AC transfer switch. It can be connected in parallel (230 VAC)
or in three phase (230/400 VAC) configurations. The sealed,
gasketed die-cast aluminum chassis protects and keeps the
power conversion components cool without requiring
115 VAC
outside air. The FX can be used in high ambient applications 60 HZ ON
up to 60 C with reduced output ratings. It is designed to REQUEST
operate with other OutBack products.
Generators
GFX Inverter/Charger Series GFX Series is a
competitive power solution designed for applications
with lower power demands. Incorporating a DC-
to-AC sinewave inverter, battery charger and AC
Electronics
transfer relay housed within a die-cast aluminum
chassis, the GFX Series give the ability to sell solar,
wind or hydro power back to the utility grid while
providing instantaneous back-up power in the event
of a utility outage.
The built in transfer relay automatically disconnects
your loads from the utility grid and powers them
from the inverter in the event of an outage, allowing
to continue using solar and battery back-up power, 60 HZ ON
unlike traditional grid-tie systems. For areas that REQUEST
frequently experience power instability, or where
standard inverters have trouble syncing to the utility
grid, the GFX International Series grid reconnect
timers have been shortened to reduce overall sell- OutBack Accessories, p. 256
back downtime and improve system functionality.
Generators
Sunny Island 3.0M, 4.4M, 6.0H/8.0H
The Sunny Island impresses with its high protection
class and wide temperature range. Thanks to OptiCool,
theres no need to compromise when it comes to
Electronics
overload capacity and economic viability. OptiPower,
the intelligent load and energy management system,
ensures operation even in critical situations. OptiUse
makes installation, commissioning and daily use easier
than ever with automatic rotary field detection, an
optimized quick configuration guide and intuitive
operation. And the intelligent OptiBat battery
management system automatically controls the most
important charging and discharging procedures, which
0DGHLQ
extends the service life of sensitive energy storage. *HUPDQ\
Sunny Island
Module
Sunny Boy
Sunny TriPower
User Household
Sunny Island
Module
Grid Inverters
Electronics
0DGHLQ
*HUPDQ\
Sunny Boy 2.5 Sunny Boy x000TL-21 Sunny Tripower Sunny Tripower
x000TL-20 xx000TL-10
Generators
Article Dimensions [l x w x h] Weight Article No.
Sunny Boy Inverter
Sunny Boy 2.5 460 x 357 x 122 mm 8,8 kg 321246
Electronics
2,5 kVA | 160 500 VDC | 230 VAC | 50 Hz | IP65
Sunny Boy 3000TLST-21 490 x 519 x 185 mm 26 kg 321109
3,2 kVA | 213 500 VDC | 230 VAC | 50 Hz | IP65
Sunny Boy 4000TL-21 470 x 445 x 180 mm 25 kg 321110
4 kVA | 125 440 VDC | 230 VAC | 50 Hz | IP54
Sunny Boy 5000TL-21 470 x 445 x 180 mm 25 kg 321111
5 kVA | 125 440 VDC | 230 VAC | 50 Hz | IP54
Sunny Tripower
Sunny Tripower 5000TL-20 470 x 730 x 240 mm 37 kg 321168
5 kVA | 245 800 VDC | 230 400 VAC | 50/60 Hz | IP65
Sunny Tripower 6000TL-20 470 x 730 x 240 mm 37 kg 321169
6 kVA | 295 800 VDC | 230 400 VAC | 50/60 Hz | IP65
Sunny Tripower 7000TL-20 470 x 730 x 240 mm 37 kg 321170
7 kVA | 290 800 VDC | 230 400 VAC | 50/60 Hz | IP65
Sunny Tripower 8000TL-20 470 x 730 x 240 mm 37 kg 321116
8 kVA | 330 800 VDC | 230 400 VAC | 50/60 Hz | IP65
Sunny Tripower 9000TL-20 470 x 730 x 240 mm 37 kg 321171
9 kVA | 370 800 VDC | 230 400 VAC | 50/60 Hz | IP65
Sunny Tripower 10000TL-20 665 x 690 x 265 mm 65 kg 330009
10 kVA | 320 800 VDC | 230 400 VAC | 50/60 Hz | IP65
Sunny Tripower 12000TL-20 665 x 690 x 265 mm 65 kg 330008
12 kVA | 380 800 VDC | 230 400 VAC | 50/60 Hz | IP65
Sunny Tripower 15000TL-10 665 x 690 x 265 mm 65 kg 330007
15 kVA | 360 800 VDC | 230 400 VAC | 50/60 Hz | IP65
Pump Inverters
Electronics
Generators
Battery Chargers
Electronics
CHARGE BOX
Generators
DC / DC Converters
Electronics
Studer DC/DC Converters
MDCI and MDC Series
The DC/DC converters type MDCI and MDC are
used, depending on the model either to step up
or to step down a DC voltage. The MDCI range
converters are electrically isolated.
High effciency
Low consumption
Protection against short circuit, overheating
overvoltage and reverse polarity
Great stability of the output voltage for
a more reliable system
Electronics
Electronics
Steca Solar Charge Controllers p. 136
135
Kits
Steca Electronics Steca Solar Charge Controllers
Controllers
Electronics
Generators
Electronics
Solarix PRS Solar Charge Controllers
The simplicity and high performance of the Steca
Solarix PRS solar charge controller make it particularly
attractive. Here, Stecas latest algorithms are employed
in order to guarantee optimal battery maintenance.
The Solarix PRS charge controllers are equipped
with an electronic fuse, thus ensuring the optimal
protection. They operate on the serial principle, and
separate the solar module from the battery in order to
protect it against overcharging. The Solarix PRS charge Accessories,
p. 249 and following
controllers are universal charge controllers: they can be
used with lead-acid batteries or gel batteries without Programmable with RC100,
the need for complex configuration settings. For larger p. 252
projects, the charge controllers can also be equipped
with special functions: night light function, selectable
charging plateau and deep discharge protection
voltages. The Steca Solarix PRS works on PWM as a low 0DGHLQ
loss series controller. *HUPDQ\
Generators
Tarom Solar Charge Controllers
Numerous clever functions allow the user
to adjust the controller to the particular
features of the system in question. Thanks
Electronics
to the significantly improved state of charge
determination, the system is optimally
controlled and the batteries are protected.
A graphic display informs about system data
and enables configuration and adjustment of
Tarom 4545
the controller to the specific requirements of
the individual system. The Steca Tarom charge
controller is the best choice for system sizes freely configured as a timer, a night light
of up to 2,700 Wp at three voltage levels function, to start generators or as surplus
(12 VDC, 24 VDC, 48 VDC). The integrated management.
data logger stores all important system
data which can be read via an open Steca
Accessories, p. 249 and following
UART interface. As an option, an external
temperature sensor can also be connected.
0DGHLQ
Two additional switching contacts can be *HUPDQ\
Generators
Controllers with MPPT
Electronics
Solarix MPPT Charge Controllers
This MPPT charge controller optimally charges
batteries when using PV-modules of grid-
connected systems. It is a simple and reliable
device providing maximum flexibility in module
configuration. It is also possible to use thin
film modules with this device. The latest
technology guarantees professional battery care
combined with modern design and outstanding
protection features. Programmable via PA Accessories, p. 249 and following
RC100. The Steca Solarix MPPT works on PWM 0DGHLQ
as a low loss series controller. *HUPDQ\
Steca Stand
Generators
Alone Inverters
Electronics
Generators
Modules Data Master Data Slave Data Slave Data Slave
Inverter
Solarix PI 550
Electronics
Charge Master
Controller Slave 1 Slave 2
Slave 3
Power Tarom Connection Box
PAx4
Battery
Steca DC Loads
Electronics
Generators
Electronics
Solsum ESL
The electronics of these 12 VDC energy-saving compact
fluorescent lamps (CFLs) was developed by Steca and
continuously improved. Preheating, a high electronic efficiency
and low thermal losses increase the service life of these CFLs
to about 100.000 switch cycles. The Steca energy-saving lights
feature a much higher efficiency (Im/W) incandescent bulbs.
Solar Fridge
The Steca solar fridge product generation with
highest energy efficiency is perfectly optimized
for the use in solar applications. The new
A++ DC fridge generation realizes a complete
concept. Best isolation combined with a very
efficient and silent DC compressor which is
driven by a specially designed Steca electronic
compressor regulation guarantee an optimum
use of the available solar power within the
system. Optionally the Steca solar fridge
coolers can be equipped with one of the well
known Steca Solar charge regulators which
interact optimally with the fridge functionality.
In this case just a suitable battery and the
solar module has to be connected to the Steca
solar fridge to start cooling. Especially the
Steca solar fridge as a top opener is optimally
suited for applications under high ambient
temperature as it protects the content of the Made in
fridge also while the cabinet is open. Europe
Generators
Steca Accessories
Electronics
Steca PA Shunt
Intelligent hall shunt with contactless current
sensor measuring. Potential free shunt with RJ45
interface for communication with controllers for
exact SOC calculation. Parallel operation with
0DGHLQ
several PA HS shunts is possible. *HUPDQ\
Generators
Steca PA RC100 Remote
Remote control for Steca Solarix PRS, Steca Solarix MPPT
1010/2010 and Steca Solsum F Solar Charge Controller.
night light timer after sunset
Electronics
end of charge voltage (float, boost, equal voltage) 0DGHLQ
deep discharge disconnection and reconnection *HUPDQ\
Electronics
Electronics
Studer Solar Charge Controllers
with MPPT p. 152
151
Kits
Studer Electronics Studer Solar Charge Controllers with MPPT
Generators
Electronics
VarioString
Simple/Dual MPPT
Solar Charge Controllers
This Serie, thanks to its high voltage PV
inputs reduces the Balance of Systems costs
when it comes to larger systems. It eliminates
expensive wiring for parallel strings, saving
wires, junction boxes, fuses, space, time, etc.
Safe, simple and trouble free connection
with SUNCLIX
Simplified safety rules by full isolation
between PV and battery and between
MPPT inputs
Any grounding strategy applicable thanks
to isolated MPPT inputs. Grounding system
fault detection.
High conversion effciency > 98 %
4,2/2 x 3,5 kW per units and up to 15 units
in parallel BTS-01 Temperature Sensor, p. 256
Clear 9 LEDS status on current monitor RCC-02 Remote, p. 256
Studer
Generators
Generators
Article Dimensions [l x w x h] Weight Article No.
AJ 600-24-S 142 x 240 x 84 mm 4,5 kg 101308
500 VA | 24 VDC | 230 VAC | 50 Hz | IP30 | 15 A solar charge controller
Electronics
AJ 700-48 142 x 240 x 84 mm 4,5 kg 101309
500 VA | 48 VDC | 230 VAC | 50 Hz | IP30
Inverter Lines AJ 1000 / AJ 1300
AJ 1000-12 142 x 428 x 84 mm 8,5 kg 101310
800 VA | 12 VDC | 230 VAC | 50 Hz | IP30
AJ 1000-12-S 142 x 428 x 84 mm 8,5 kg 101311
800 VA | 12 VDC |230 VAC | 50 Hz | IP30 | 25 A solar charge controller
AJ 1300-24 142 x 428 x 84 mm 8,5 kg 101312
1000 VA | 24 VDC | 230 VAC | 50 Hz | IP30
AJ 1300-24-S 142 x 428 x 84 mm 8,5 kg 101313
1000 VA | 24 VDC | 230 VAC | 50 Hz | IP30 | 25 A solar charge controller
Inverter Lines AJ 2100 / AJ 2400
AJ 2100-12 273 x 399 x 117 mm 19,0 kg 101314
2000 VA | 12 VDC | 230 VAC | 50 Hz | IP30
AJ 2100-12-S 273 x 399 x 117 mm 19,0 kg 101315
2000 VA | 12 VDC | 230 VAC | 50 Hz | IP30 | 30 A solar charge controller
AJ 2400-24 273 x 399 x 117 mm 18,0 kg 101316
2000 VA | 24 VDC | 230 VAC | 50 Hz | IP30
AJ 2400-24-S 273 x 399 x 117 mm 18,0 kg 101317
2000 VA | 24 VDC | 230 VAC | 50 Hz | IP30 | 30 A solar charge controller
AC loads
AC loads
DC loads
Inverter/Charger
Electronics
XTS XTM
XTH
Generators
Article Dimensions [l x w x h] Weight Article No.
Inverter/Charger Line XTS
XTS 900-12 110 x 210 x 310 mm 8,2 kg 320070
Electronics
900 VA | 12 VDC | 230 VAC | 50 Hz | IP54 | BC 0 35 A
XTS 1200-24 110 x 210 x 310 mm 9,0 kg 320071
1200 VA | 24 VDC | 230 VAC | 50 Hz | IP54 | BC 0 20 A
XTS 1400-48 110 x 210 x 310 mm 9,3 kg 320072
1400 VA | 48 VDC | 230 VAC | 50 Hz | IP54 | BC 0 10 A
Inverter/Charger Line XTM
XTM 1500-12 133 x 322 x 466 mm 15 kg 303040
1500 VA | 12 VDC | 230 VAC | 50 Hz | BC 0 70 A
XTM 2000-12 133 x 322 x 466 mm 18,5 kg 106001
2000 VA | 12 VDC | 230 VAC | 50 Hz | BC 0 100 A
XTM 2400-24 133 x 322 x 466 mm 16,2 kg 303043
2000 VA | 24 VDC | 230 VAC | 50 Hz | BC 0 55 A
XTM 2600-48 133 x 322 x 466 mm 16,2 kg 303045
2000 VA | 48 VDC | 230 VAC | 50 Hz | BC 0 30 A
XTM 3500-24 133 x 322 x 466 mm 21,2 kg 106002
3000 VA | 24 VDC | 230 VAC | 50 Hz | BC 0 90 A
XTM 4000-48 133 x 322 x 466 mm 22,9 kg 106003
3500 VA | 48 VDC | 230 VAC | 50 Hz | BC 0 50 A
Inverter/Charger Line XTH
XTH 3000-12 230 x 300 x 500 mm 34,0 kg 106381
2500 VA | 12 VDC | 230 VAC | 50 Hz | IP20 | BC 0 160 A
XTH 5000-24 230 x 300 x 500 mm 40,0 kg 106382
4500 VA | 24 VDC | 230 VAC | 50 Hz | IP20 | BC 0 140 A
XTH 6000-48 230 x 300 x 500 mm 42,0 kg 106383
5000 VA | 48 VDC | 230 VAC | 50 Hz | IP20 | BC 0 100 A
XTH 8000-48 230 x 300 x 500 mm 46,0 kg 106384
7000 VA | 48 VDC | 230 VAC | 50 Hz | IP20 | BC 0 120 A
local/remote communication
Generator AC loads
XPC
-S means solar charge controller integrated.
Article Dimensions [l x w x h] Weight Article No.
Inverter/Charger Line XPC
XPC 1400-12 410 x 215 x 124 mm 11,7 kg 101375
1100 VA | 12 VDC | 230 VAC | 50 Hz | IP20 | BC 0 45 A
XPC 2200-24 410 x 215 x 124 mm 12,6 kg 101376
1600 VA | 24 VDC | 230 VAC | 50 Hz | IP20 | BC 0 37 A
XPC 2200-48 410 x 215 x 124 mm 12,6 kg 101377
1600 VA | 48 VDC | 230 VAC | 50 Hz | IP20 | BC 0 20 A
XPC 1400-12-S 410 x 215 x 124 mm 11,7 kg 106319
1100 VA | 12 VDC | 230 VAC | 50 Hz | IP20 | BC 0 45 A / 30 A SCC
XPC 2200-24-S 410 x 215 x 124 mm 12,6 kg 106320
1600 VA | 24 VDC | 230 VAC | 50 Hz | IP20 | BC 0 37 A / 30 A SCC
XPC 2200-48-S 410 x 215 x 124 mm 12,6 kg 106321
1600 VA | 48 VDC | 230 VAC | 50 Hz | IP20 | BC 0 20 A / 20 A SCC
Generator
AC loads
Generators
Studer Battery Chargers
Electronics
Studer Battery Chargers
The MBC chargers enable battery charging
from an AC voltage supply source (genset,
public grid, shorepower, etc).
Watertight (IP65), specially designed for
outdoor applications
Universal input voltage
Charge of lead acid batteries with liquid or
GEL electrolyte
Protection against battery overcharge
Studer
Generators
DC / DC Converters
Electronics
Generators
Studer Accessories
Electronics
Studer Inverter/Charger Accessories
X-Connect System:
The X-Connect frame offers a flexible and
cost effective solution for high power systems
based on XTH inverter.
Studer AJ Accessories
Studer RCC-02 Studer RCC-03 Studer BTS-01 Studer Cooling Fan Studer BSP
NEW
Generators
Studer Compact Accessories
Electronics
Studer RCC-01 Studer CT-35 Studer ARM-01 Studer CFC-01 Studer C-IP22
Generators
Electronics
Article Dimensions [l x w x h] Weight Article No.
Battery Watch MBW 40 80 x 60 x 40 mm 200 g 303571
40 A | 12/24 VDC | LVD12: 10 11,5 VDC | LVD24: 21,5 23 VDC
Battery Watch MBW 60 80 x 60 x 40 mm 200 g 303572
60 A | 12/24 VDC | LVD12: 10 11,5 VDC | LVD24: 21,5 23 VDC
Battery Watch MBW 200 145 x 92 x 85 mm 580 g 303573
200 A | 12/24 VDC | LVD12: 10 11,5 VDC | LVD24: 21,5 23 VDC
Battery Separator MBR 12/24-100 46 x 46 x 80 mm 110 g 390308
100 A | 12/24 VDC | 2 x Battery
Battery Separator MBR 12/24-160 46 x 93 x 96 mm 300 g 390309
160 A | 12/24 VDC | 2 x Battery
Battery Separator MBR 12/24-500 72 x 70 x 80 mm 417 g 390310
500 A | 12/24 VDC | 2 x Battery
Battery Splitter MBI 100/2 146 x 85 x 92 mm 780 g 390459
100 A | 12/24 VDC | 1 x Charger input | 2 x Battery
Battery Splitter MBI 150/2 146 x 85 x 92 mm 810g 390913
150 A | 12/24 VDC | 1 x Charger input | 2 x Battery
Battery Splitter MBI 100/3 146 x 85 x 152 mm 780 g 390914
100 A | 12/24 VDC | 1 x Charger input | 3 x Battery
Battery Splitter MBI 150/3 92 x 85 x 146 mm 780 g 390883
150 A | 12/24 VDC | 1 x Charger input | 3 x Battery
Battery Splitter MBI 200/3 146 x 85 x 152 mm 815 g 390915
200 A | 12/24 VDC | 1 x Charger input | 3 x Battery
Battery Splitter MBI 2-100/3 146 x 85 x 152 mm 780 g 390916
100 A | 12/24 VDC | 2 x Charger input | 3 x Battery
Electronics
AGM Batteries p. 170
Batteries
Information about
battery terminals, p. 336
PLEASE
NOTE!
The return of used batteries is mandatory while their disposal in the municipal
waste is prohibited by the law. Used batteries must be accepted by mail order
firms free of charge; the customer shall bear the shipping costs. Batteries contain heavy
metals which cause damages to both human health and environment. These poisonous
heavy metals are identified on the battery. The crossed out waste container with the
chemical sign Hg (mercury), Cd (cadmium) and Pb (lead) explains the disposal obligation and
the heavy metals contained. Please also refer to Acceptance of Used Batteries on p. 334.
169
Kits
Batteries AGM Batteries
Generators
AGM Batteries
Electronics
Generators
Electronics
AGM Batteries Store Rich
The Phaesun Store Rich battery is a completely
maintenance-free, high performance battery
equipped with recombination technology
providing extremely high cycle stability.
Due to the standardized L3 and L5 dimensions
it is ideal for the use in camping and caravans.
Batteries
Article Dimensions [l x w x h] Weight Article No.
Store Rich 70 278 x 175 x 190 mm 20 kg 340133
78 Ah (C100), 72 Ah (C20), 67 Ah (C10) | 12 VDC | L3 | A terminal
Store Rich 90 353 x 175 x 190 mm 34 kg 340134
98 Ah (C100), 92 Ah (C20), 88 Ah (C10)| 12 VDC | L5 | A terminal
Power.com Batteries
These Hoppecke AGM batteries are based on using
flat plate technology and fixing the electrolyte
inside glass mats (AGM). The high energy density of
Electronics
Generators
Solar.bloc
These batteries are based on an optimised flat
plate and an electrolyte fixed in glass mats
which even take the separating function.
Electronics
solar.bloc batteries are maintenance free and
offer a very good cycling expectancy and an
efficient charge current consumption. For Off-
Grid applications.
Batteries
solar.bloc 12 V 90 353 x 175 x 190 mm 28 kg 105082
90 Ah (C100) | 12 VDC | A terminal
solar.bloc 12 V 105 344 x 177 x 230 mm 38 kg 105083
100 Ah (C100) | 12 VDC | M8 terminal
solar.bloc 12 V 135 344 x 170 x 275 mm 46 kg 105084
130 Ah (C100) | 12 VDC | M8 terminal
solar.bloc 12 V 150 498 x 177 x 230 mm 55 kg 105085
150 Ah (C100) | 12 VDC | M8 terminal
solar.bloc 6 V 200 242 x 170 x 275 mm 32 kg 105086
190 Ah (C100) | 6 VDC | M8 terminal
solar.bloc 6 V 250 308 x 170 x 275 mm 41 kg 340034
250 Ah (C100) | 6 VDC | M8 terminal
Generators
Article Dimensions [l x w x h] Weight Article No.
Block-Power BP 12-65 350 x 165 x 178 mm 22,0 kg 302426
65 Ah (C20) | 12 VDC | M6 terminal
Block-Power BP 12-75 260 x 170 x 210 mm 23,8 kg 302427
Electronics
78 Ah (C20) | 12 VDC | M6 terminal
Block-Power BP 12-100 330 x 173 x 220 mm 31,0 kg 302428
107 Ah (C20) | 12 VDC | M8 terminal
Block-Power BP 12-120 410 x 177 x 225 mm 38,0 kg 302429
124 Ah (C20) | 12 VDC | M8 terminal
Block-Power BP 12-140 344 x 171 x 280 mm 45,0 kg 302430
149 Ah (C20) | 12 VDC | M8 terminal
Block-Power BP 12-150 485 x 170 x 242 mm 48,0 kg 302431
156 Ah (C20) | 12 VDC | M8 terminal
Block-Power BP 12-200 522 x 240 x 224 mm 66,0 kg 302432
208 Ah (C20) | 12 VDC | M8 terminal
Block-Power BP 12-250 522 x 255 x 220 mm 73,0 kg 302433
262 Ah (C20) |12 VDC | M8 terminal
Batteries
2 V AND 6 V
BATTERIES
ON
Rolls AGM 12 V Monobloc Series REQUEST
Features:
12 V heavy duty deep cycle Low self discharge rate
5 year warranty Low internal resistance
Maintenance-free, non-hazardous Rugged construction
Gel Batteries
Electronics
Gel-Power Batteries
The advantages of Intact Gel-Power batteries
over its conventional counterpart are numerous:
Maintenance free
No leakage of liquid and gas
Low in self-discharge rate
Able to operate in a wide temperature range
Economical and at long life
Designed for high-discharging purpose
Excellent performance in difficult climatic Battery Boxes, p. 263
circumstances Acceptance of used batteries, p. 334
(B = bottom lath: lath to fix the battery in
Batteries
0DGHLQ
a motor vehicle) *HUPDQ\
Generators
Electronics
Article Dimensions [l x w x h] Weight Article No.
Gel-Power 75 260 x 171 x 210 mm 23,0 kg 302477
80 Ah (C100) | 12 VDC | M6 terminal
Gel-Power 80 B 353 x 175 x 190 mm 26,0 kg 302478
85 Ah (C100) | 12 VDC | bottom lath | A terminal
Gel-Power 85 330 x 171 x 236 mm 32,0 kg 340135
90 Ah (C100) | 12 VDC | A terminal
Gel-Power 115 286 x 269 x 230 mm 40,0 kg 302480
130 Ah (C100) | 12 VDC | A terminal
Gel-Power 120 519 x 189 x 223 mm 41,0 kg 302481
135 Ah (C100) | 12 VDC | A terminal
Gel-Power 125 345 x 175 x 290 mm 40,0 kg 302482
Batteries
140 Ah (C100) | 12 VDC | A terminal
Gel-Power 140 513 x 223 x 223 mm 48,0 kg 302483
155 Ah (C100) | 12 VDC | A terminal
Gel-Power 210 518 x 291 x 242 mm 70,0 kg 302484
230 Ah (C100) | 12 VDC | A terminal
Gel-Power 180-06 V1 244 x 190 x 275 mm 33,0 kg 302485
200 Ah (C100) | 6 VDC | A terminal
Gel-Power 180-06 V2 261 x 181 x 269 mm 33,0 kg 302486
200 Ah (C100) | 6 VDC | A terminal
Gel-Power 300-06 312 x 180 x 359 mm 48,0 kg 302487
330 Ah (C100) | 6 VDC | A terminal
er,
r -Pow
t Sola
int Ac
86
page 1
ower,
c t Gel- P
int A
76
page 1 ower,
c t AGM -P
intAct AGM-Power int A
74
batteries are used in page 1
a number of smaller
solar applications.
Generators
OPzV solar.power and OPzV bloc
solar.power Batteries
These batteries are specially designed
for Off-Grid photovoltaic applications
Electronics
such as DC systems, AC coupled systems,
telecommunication centres and in control,
signalling and UPS installations. With their
leak proof design and good resistance to deep
discharge, they are a reliable type of battery,
also characterised by low self-discharge.
For easy installation and replacement the OPzV solar.power OPzV bloc solar.power
OPzV solar.power is designed according to
DIN 40742 and the OPzV bloc solar.power
according to DIN 40744.
0DGHLQ
Horizontal Installation on request! *HUPDQ\
Batteries
OPzV bloc solar.power
12V 1 OPzV bloc solar.power 70 272 x 205 x 383 mm 40,0 kg 340083
70 Ah (C100) | 12 VDC | M8 terminal
12V 2 OPzV bloc solar.power 120 272 x 205 x 383 mm 52,5 kg 340029
130 Ah (C100) | 12 VDC | M8 terminal
12V 3 OPzV bloc solar.power 180 380 x 205 x 383 mm 75,0 kg 340030
200 Ah (C100) | 12 VDC | M8 terminal
6V 4 OPzV bloc solar.power 250 272 x 205 x 383 mm 51,0 kg 340031
270 Ah (C100) | 6 VDC | M8 terminal
6V 5 OPzV bloc solar.power 300 380 x 205 x 383 mm 66,0 kg 340032
330 Ah (C100) | 6 VDC | M8 terminal
6V 6 OPzV bloc solar.power 370 380 x 205 x 383 mm 73,0 kg 340033
400 Ah (C100) | 6 VDC | M8 terminal
OPzV solar.power
4 OPzV solar.power 250 105 x 208 x 420 mm 18,3 kg 303370
287 Ah (C100) | 2 VDC | M8 terminal
5 OPzV solar.power 310 126 x 208 x 420 mm 22,3 kg 303371
359 Ah (C100) | 2 VDC | M8 terminal
6 OPzV solar.power 370 147 x 208 x 420 mm 26,5 kg 303372
430 Ah (C100) | 2 VDC | M8 terminal
82
page 1
ing,
follow
91 and
pa 1
g e
ing,
follow
Batteries
Made in Europe
GNB has the solar energy solutions you are looking for
GNB Industrial Power is a global leader in renewable energy storage with strong
capabilities in both large- and small-scale storage of renewable energy. Our aim is
to create storage solutions for grid-connected wind and solar farms, and large,
commercial and industrial installations.
www.gnb.com
Generators
Sonnenschein Solar
These batteries are especially designed for small
to medium performance requirements in leisure
and consumer applications. The advantages of the
Electronics
maintenance-free batteries are enhanced by the
worldwide high reputation and technical image of the
dryfit gel technology. Typical applications are weekend
and holiday houses without mains supply, street solar
stations, information signs, parking meters, wireless
emergency phone boxes and other safety equipment
power supplies. Sonnenschein solar batteries are very
long-lived, have very good cycling and extremely reliable
depth-of-discharge characteristics. They are especially
determined for small solar systems (800 cycles at 60 %
0DGHLQ
depth of discharge). *HUPDQ\
Batteries
Sonnenschein Solar S12/17.0 G5 181 x 76 x 167 mm 6,1 kg 101806
17 Ah (C100) | 12 VDC | D5 terminal
Sonnenschein Solar S12/27 G5 176 x 167 x 126 mm 9,6 kg 101807
27 Ah (C100) | 12 VDC | D5 terminal
Sonnenschein Solar S12/32 G6 197 x 132 x 184 mm 11,1 kg 101808
32 Ah (C100) | 12 VDC | D6 terminal
Sonnenschein Solar S12/41 A 210 x 175 x 175 mm 14,2 kg 101809
41 Ah (C100) | 12 VDC | A terminal
Sonnenschein Solar S12/60 A 261 x 136 x 230 mm 18,1 kg 101810
60 Ah (C100) | 12 VDC | A terminal
Sonnenschein Solar S12/85 A 353 x 175 x 190 mm 26,8 kg 101811
85 Ah (C100) | 12 VDC | A terminal
Sonnenschein Solar S12/90 A 330 x 171 x 236 mm 29,2 kg 101812
90 Ah (C100) | 12 VDC | A terminal
Sonnenschein Solar S12/130 A 286 x 269 x 230 mm 37,5 kg 101813
130 Ah (C100) | 12 VDC | A terminal
Sonnenschein Solar S12/230 A 518 x 274 x 238 mm 67,0 kg 101814
230 Ah (C100) | 12 VDC | A terminal
Generators
Deep-Cycle Gel Batteries
Trojans deep-cycle gel batteries are sealed,
maintenance-free batteries that deliver superior
power in demanding renewable energy
Electronics
applications. Engineered for rugged durability,
outstanding performance and long battery
life, Trojans deep-cycle gel batteries feature
a number of important design characteristics
that provide significant advantages over
competing gel products. The gelled electrolyte
is a proprietary formulation that delivers
consistent performance and dramatically
extends the batterys cycle life. Lead alloy grids
provide longer shelf life and superior corrosion
resistance as well as deliver more concentrated
energy to the terminals. Its premium grade,
double-insulated separators allow maximum
charge flow between the plates for optimum
performance.
Batteries
Article Dimensions [l x w x h] Weight Article No.
Battery 24-GEL 276 x 167 x 236 mm 24 kg 340176
72 Ah (C10) | 12 VDC | A terminal, S8 terminal
Battery 27-GEL 326 x 171 x 234 mm 29 kg 340177
84 Ah (C10) | 12 VDC | A terminal, D10 terminal
Battery 31-GEL 329 x 171 x 245 mm 32 kg 340178
94 Ah (C10) | 12 VDC | A terminal, D10 terminal
Battery 5SHP-GEL 345 x 171 x 283 mm 39 kg 340179
115 Ah (C10) | 12 VDC | D10 terminal
Battery 8D-GEL 534 x 279 x 233 mm 71 kg 340180
207 Ah (C10) | 12 VDC | D10 terminal
Flooded Batteries
Electronics
Solar-Power Batteries
The special technical lay-out of the Intact
lead-acid solar battery makes them ideal for
photovoltaic systems. A high reliability, robust
casing and a minimal selfconsumption are special
features of this battery. The temperature range Made in
of the cycles ranges from 20 C up to + 45 C. Europe
Generators
Electronics
Article Dimensions [l x w x h] Weight Article No.
Solar-Power 125 GUG 394 x 175 x 190 mm 28,7 kg 302462
125 Ah (C100) | 12 VDC | A terminal
Solar-Power 128 GUG 330 x 172 x 242 mm 23,7 kg 302463
128 Ah (C100) | 12 VDC | A terminal
Solar-Power 130 GUG 348 x 175 x 284 mm 32,3 kg 302464
Solar-Power 130 TV 348 x 175 x 284 mm 21,7 kg 302450
130 Ah (C100) | 12 VDC | A terminal
Solar-Power 140 GUG 513 x 189 x 223 mm 37,2 kg 302465
Solar-Power 140 TV 513 x 189 x 223 mm 26,9 kg 302451
140 Ah (C100) | 12 VDC | A terminal
Batteries
Solar-Power 200 GUG 513 x 223 x 223 mm 48 kg 302466
Solar-Power 200 TV 513 x 223 x 223 mm 31,6 kg 302452
200 Ah (C100) | 12 VDC | A terminal
Solar-Power 250 GUG 518 x 276 x 242 mm 61 kg 302467
Solar-Power 250 TV 518 x 276 x 242 mm 40,6 kg 302453
250 Ah (C100) | 12 VDC | A terminal
Solar-Power 280 GUG 244 x 190 x 275 mm 29,5 kg 302468
280 Ah (C100) | 6 VDC | A terminal
Generators
Article Dimensions [l x w x h] Weight Article No.
OPzS solar.power (GUG = Filled and Charged, TV = Dry Preloaded)
4 OPzS solar.power 280 GUG 208 x 105 x 420 mm 17,1 kg 340021
4 OPzS solar.power 280 TV 208 x 105 x 420 mm 12,6 kg 340001
Electronics
280 Ah (C100) | 2 VDC | M8 terminal
5 OPzS solar.power 350 GUG 208 x 126 x 420 mm 20,7 kg 340022
5 OPzS solar.power 350 TV 208 x 126 x 420 mm 15,1 kg 340002
350 Ah (C100) | 2 VDC | M8 terminal
6 OPzS solar.power 420 GUG 208 x 147 x 420 mm 24,6 kg 340023
6 OPzS solar.power 420 TV 208 x 147 x 420 mm 17,9 kg 340003
420 Ah (C100) | 2 VDC | M8 terminal
5 OPzS solar.power 520 GUG 208 x 126 x 535 mm 29,1 kg 340024
5 OPzS solar.power 520 TV 208 x 126 x 535 mm 20,6 kg 340004
520 Ah (C100) | 2 VDC | M8 terminal
6 OPzS solar.power 620 GUG 208 x 147 x 535 mm 34,1 kg 340025
6 OPzS solar.power 620 TV 208 x 147 x 535 mm 24,0 kg 340005
620 Ah (C100) | 2 VDC | M8 terminal
7 OPzS solar.power 730 GUG 208 x 168 x 535 mm 39,2 kg 340026
7 OPzS solar.power 730 TV 208 x 168 x 535 mm 27,5 kg 340006
Batteries
730 Ah (C100) | 2 VDC | M8 terminal
6 OPzS solar.power 910 GUG 208 x 147 x 710 mm 46,1 kg 340027
6 OPzS solar.power 910 TV 208 x 147 x 710 mm 32,8 kg 340007
910 Ah (C100) | 2 VDC | M8 terminal
8 OPzS solar.power 1220 GUG 215 x 193 x 710 mm 63,1 kg 340028
8 OPzS solar.power 1220 TV 215 x 193 x 710 mm 45,8 kg 340008
1220 Ah (C100) | 2 VDC | M8 terminal
9 OPzS solar.power 1370 GUG 215 x 235 x 710 mm 72,4 kg 340100
9 OPzS solar.power 1370 TV 215 x 235 x 710 mm 51,9 kg 340099
1370 Ah (C100) | 2 VDC | M8 terminal
10 OPzS solar.power 1520 GUG 215 x 235 x 710 mm 76,4 kg 340065
10 OPzS solar.power 1520 TV 215 x 235 x 710 mm 55,3 kg 340009
1520 Ah (C100) | 2 VDC | M8 terminal
11 OPzS solar.power 1670 GUG 215 x 277 x 710 mm 86,6 kg 340105
11 OPzS solar.power 1670 TV 215 x 277 x 710 mm 61,4 kg 340104
1670 Ah (C100) | 2 VDC | M8 terminal
Generators
Classic OPzS Solar
These batteries have been well-proven for decades in
medium and large photovoltaic systems. Based on DIN
standard sizes and tubular flooded plate technology,
Electronics
the Classic OPzS Solar batteries provide the highest
level of reliability and cycle life with low maintenance,
thanks to a large electrolyte reserve. Due to their
robustness, long life and high operational safety they
are ideally suitable for use in solar and wind systems,
telecommunications and other safety power supplies.
(up to 3000 cycles at 60 % depth of discharge).
Batteries
81 Ah (C100) | 12 VDC | M8 terminal
Classic OPzS Solar Block 140 GUG 272 x 206 x 347 mm 45,0 kg 340057
Classic OPzS Solar Block 140 TV 272 x 206 x 347 mm 31,0 kg 104701
136 Ah (C100) | 12 VDC | M8 terminal
Classic OPzS Solar Block 210 GUG 380 x 206 x 347 mm 64,0 kg 340058
Classic OPzS Solar Block 210 TV 380 x 206 x 347 mm 45,0 kg 104702
203 Ah (C100) | 12 VDC | M8 terminal
Classic OPzS (GUG = Filled and Charged, TV = Dry Preloaded) 6 V bloc
Classic OPzS Solar Block 280 GUG 272 x 206 x 347 mm 41,0 kg 340059
Classic OPzS Solar Block 280 TV 272 x 206 x 347 mm 28,0 kg 104703
287 Ah (C100) | 6 VDC | M8 terminal
Classic OPzS Solar Block 350 GUG 380 x 206 x 347 mm 56,0 kg 340060
Classic OPzS Solar Block 350 TV 380 x 206 x 347 mm 36,0 kg 104704
355 Ah (C100) | 6 VDC | M8 terminal
Classic OPzS Solar Block 420 GUG 380 x 206 x 347 mm 63,0 kg 340061
Classic OPzS Solar Block 420 TV 380 x 206 x 347 mm 43,0 kg 104705
408 Ah (C100) | 6 VDC | M8 terminal
Find more Classic OPzS solar batteries from GNB batteries on the next page.
Find more Classic OPzS solar batteries from GNB on the next page.
Generators
Article Dimensions [l x w x h] Weight Article No.
Classic OPzS Solar 1410 GUG 212 x 193 x 686 mm 63,4 kg 340046
Classic OPzS Solar 1410 TV 212 x 193 x 686 mm 46,6 kg 104717
Electronics
1380 Ah (C100) | 2 VDC | M8 terminal
Classic OPzS Solar 1650 GUG 212 x 235 x 686 mm 73,2 kg 340047
Classic OPzS Solar 1650 TV 212 x 235 x 686 mm 51,5 kg 104718
1620 Ah (C100) | 2 VDC | M8 terminal
Classic OPzS Solar 1990 GUG 212 x 277 x 686 mm 86,4 kg 340048
Classic OPzS Solar 1990 TV 212 x 277 x 686 mm 60,3 kg 104719
1950 Ah (C100) | 2 VDC | M8 terminal
Classic OPzS Solar 2350 GUG 212 x 277 x 836 mm 108,0 kg 340049
Classic OPzS Solar 2350 TV 212 x 277 x 836 mm 74,3 kg 104720
2300 Ah (C100) | 2 VDC | M8 terminal
Classic OPzS Solar 2500 GUG 215 x 277 x 836 mm 114,0 kg 340050
Classic OPzS Solar 2500 TV 215 x 277 x 836 mm 81,3 kg 104721
2445 Ah (C100) | 2 VDC | M8 terminal
Classic OPzS Solar 3100 GUG 215 x 400 x 812 mm 151,0 kg 340051
Classic OPzS Solar 3100 TV 215 x 400 x 812 mm 101,0 kg 106722
3040 Ah (C100) | 2 VDC | M8 terminal
Batteries
Classic OPzS Solar 3350 GUG 215 x 400 x 812 mm 158,0 kg 340052
Classic OPzS Solar 3350 TV 215 x 400 x 812 mm 110,0 kg 104723
3280 Ah (C100) | 2 VDC | M8 terminal
Classic OPzS Solar 3850 GUG 215 x 490 x 812 mm 184,0 kg 340053
Classic OPzS Solar 3850 TV 215 x 490 x 812 mm 124,0 kg 104724
3765 Ah (C100) | 2 VDC | M8 terminal
Classic OPzS Solar 4100 GUG 215 x 490 x 812 mm 191,0 kg 340054
Classic OPzS Solar 4100 TV 215 x 490 x 812 mm 133,0 kg 104725
4000 Ah (C100) | 2 VDC | M8 terminal
Classic OPzS Solar 4600 GUG 215 x 580 x 812 mm 217,0 kg 340055
Classic OPzS Solar 4600 TV 215 x 580 x 812 mm 146,0 kg 104726
4500 Ah (C100) | 2 VDC | M8 terminal
Superior cycling
performance 3200 @ 50 % D.O.D
10 year warranty for maximum system
durability
Capacity range from
503 Ah 6853 Ah (C100)
PRODUCT OF CANADA
Generators
Rolls Solar 4500 and 5000 Battery Series
Features:
Elimination of 'stray' current
Electronics
No acid leakage / no racks required
Easy 'on site' assembly
Less connections resulting in an increase in
charge efficiency
10 year warranty
3200 cycles @ 50 % D.O.D
Less maintenance with optional 'Hydrocaps'
Link leads, terminal covers, nuts and bolts
all included for immediate installation
Filled and charged
Batteries
Article Dimensions [l x w x h] Weight Article No.
Series 5000
Solar 5000 12 CS 11P 559 x 286 x 464 mm 123 kg 104876
503 Ah (C100) | 12 VDC | D8 terminal
Solar 5000 6 CS 17P 559 x 210 x 464 mm 100 kg 104871
770 Ah (C100) | 6 VDC | D8 terminal
Solar 5000 6 CS 21P 559 x 248 x 464 mm 123 kg 104872
963 Ah (C100) | 6 VDC | D8 terminal
Solar 5000 6 CS 25P 559 x 286 x 464 mm 144 kg 104873
1156 Ah (C100) | 6 VDC | D8 terminal
Solar 5000 4 CS 17P 365 x 210 x 464 mm 58 kg 104868
770 Ah (C100) | 4 VDC | D8 terminal
Solar 5000 4 KS 21P 400 x 238 x 629 mm 121 kg 104869
1557 Ah (C100) | 4 VDC | D8 terminal
Solar 5000 4 KS 25P 400 x 220 x 629 mm 143 kg 104870
1904 Ah (C100) | 4 VDC | D8 terminal
Solar 5000 2 KS 33P 392 x 211 x 630 mm 94 kg 104866
2490 Ah (C100) | 2 VDC | D8 terminal
Solar 5000 2 YS 31P 394 x 229 x 803 mm 129 kg 104867
3426 Ah (C100) | 2 VDC | D8 terminal
Series 4500
Solar 4500 S-500EX 318 x 181 x 425 mm 60 kg 340168
504 Ah (C100) | 6 VDC | D8 terminal
Solar 4500 S-1400EX 340 x 181 x 432 mm 58 kg 340167
1408 Ah (C100) | 2 VDC | D8 terminal
Rely on Trojan Battery to unleash your storage needs. As a global company with
local expertise, Trojans wide range of deep-cycle flooded, AGM and Gel batteries
for renewable energy, hybrid and backup power systems are backed by more than
90 years of battery innovation.
www.trojanbattery.com
Generators
Industrial Line Batteries
Trojans Industrial Line of deep-cycle batteries is
the newest addition to Trojans lineage of high-
quality flooded batteries. The Industrial Line is
Electronics
engineered specifically to support renewable
energy systems with large daily loads where
the batteries are cycled regularly. These high
amp-hour capacity batteries are ideal for use in
large off-grid photovoltaic (PV) systems, off-grid
hybrid PV systems, grid-tied PV systems with
battery backup, smart grid peak shifting systems
and a variety of other applications. Tested to
meet industry standards, the Industrial Line
features advanced battery technologies that
deliver reliable power and is housed in a dual
container construction for enhanced battery
protection. Trojans Industrial line is the perfect
combination of performance and function.
Batteries
Article Dimensions [l x w x h] Weight Article No.
Battery IND9-6V 390 x 260 x 610 mm 100 kg 340171
414 Ah (C10) | 6 VDC | D10 terminal
Battery IND13-6V 568 x 260 x 610 mm 143 kg 340172
616 Ah (C10) | 6 VDC | D10 terminal
Battery IND17-6V 678 x 260 x 610 mm 188 kg 340173
820 Ah (C10) | 6 VDC | D10 terminal
Battery IND27-2V 390 x 260 x 610 mm 104 kg 340174
1368 Ah (C10) | 2 VDC | D10 terminal
Battery IND33-2V 440 x 260 x 610 mm 125 kg 340175
1682 Ah (C10) | 2 VDC | D10 terminal
Lithium Batteries
Electronics
Solar Side
Solar Side lithium batteries can supply
lamps, small TVs and other standard 12 VDC
appliances up to 60 W. Due to its three load
outlets (5 A) and the USB-Outlet (1,5 A) it can
be connected to the loads like a plug & play
solution. The built in management system
ensures optimized operation of a long life
LiFePO4 battery. The USB outlet allows many
5 V USB devices to be recharged or operated.
information on:
Remaining operation time
State of charge
System status.
Generators
Electronics
Power Green Vision LiFePo4 These batteries are low weight batteries, extemely resistant
against peak current and universally applicable. Due to the BMS (battery management system)
protection circuitry, they can be charged with commercial lead charging devices.
Features:
High intrinsic safety
Can be charged quickly
Universally applicable
2000 cycles with 100 % discharge
Wide temperature range 30 to +60 C
1/3 weight compared with lead batteries
Protection circuitry
Batteries
Article Dimensions [l x w x h] Weight Article No.
Power Green Lithium Battery LiFePO4 | voltage range 9,6 to 14,8 V
LFP124.5 T | 4,5 Ah | B6.3 terminal 90 x 70 x 101 mm 0,8 kg 340153
LFP1210 | 10 Ah | B6.3 terminal 150 x 65 x 107 mm 1,4 kg 340154
LFP1215 | 15 Ah | B6.3 terminal 150 x 98 x 101 mm 1,8 kg 340155
LFP1217 | 17 Ah | M5 terminal 181 x 77 x 167 mm 2,7 kg 340156
LFP1225 | 25 Ah | M5 terminal 166 x 175 x 125 mm 4,0 kg 340157
LFP1240 | 40 Ah | M5 terminal 185 x 140 x 180 mm 6,4 kg 340158
Generators
NEW BMZ ESS3.0
BMZ ESS3.0 are scalable up to 12 units.
The decisive advantages compared with
conventional batteries:
Electronics
3 to 5 times longer service life,
high cycle durability,
97 % efficiency and an extremely
compact design
Applicable with SMA Sunny Island
6.0H, 8.0H
An integrated BMS supervises all relevant
parameters and communicates data and
alarms. In case of malfunction, it can enforce a
system shutdown. Integrated fuses and safety
vents guarantees a secure operation.
Batteries
Electronics
LED Lamps p. 204
Refrigerators and
Freezer Boxes p. 214
DC Fans p. 218
DC Televisions p. 220
Batteries
Loads
203
Kits
Loads LED Lamps
Generators
LED Lamps
Electronics
20/50/100/300 lm | 3,3 W | 5VDC | neutral white | reflector | 4 m cable | USB connector | IP44
Loads
Generators
LED E27 Lamp Sun Flower
The Sun Flower lamps are high lumen output, long life,
reliable lamps for indoor lighting applications. Due to their
advanced and unique over temperature protection, they can
Electronics
withstand extreme conditions. Using high frequency switching
LED driver technology with no electrolytic capacitors, they
provide excellent performance in light efficiency, lifetime and
reliability. The unique heat sink design with no fins or gaps
avoids any insects or dust blocking the heat dissipation.
Batteries
5 W | 12 VDC | 450 lm | cool white | E27 | IP50
Sun Flower 630_12 122 x 122 x 63 mm 117 g 360149
7 W | 12 VDC | 630 lm | cool white | E27 | IP50
Loads
NEW LED Lamps Steca
Steca LEDs are modern, compact LED lamps that
are specially developed for all 12 V and 24 V direct
voltage applications. This makes them ideal for all
lighting in leisure, caravan and home applications.
Their high efficiency and excellent light yield make
them particularly suitable for solar home systems.
Article Dimensions [l x w x h] Weight Article No.
LED Lamp Steca LED 4 105 x 60 mm 10 g 360171
4,4 W | 12/24 VDC | 500 lm | neutral white | E27
LED Lamp Steca LED 6 135 x 65 mm 12 g 360172
5,6 W | 12/24 VDC | 600 lm | neutral white | E27
LED Lamp Steca LED 8 135 x 75 mm 15 g 360173
7,8 W | 12/24 VDC | 800 lm | neutral white | E27
LED Lamp Steca LED 12 161 x 88 mm 29 g 360174
11,5 W | 12/24 VDC | 1100 lm | neutral white | E27
Generators
LED Lighting Unit Ray Single and Twin
Immediate bright and efficient lighting inside
buildings or in cold rooms such as garages
or trailers. As they yield immediately full light
Electronics
output they are also ideal for the use in
combination with motion detectors. Phaesun
Ray are ready for connection and optimised for
battery Off-Grid operation. The lighting units
are available in four different versions: with one Replacement tubes, p. 275
or two light tubes with a length of 60 cm or 0DGHLQ
120 cm. *HUPDQ\
Batteries
Ray Twin 2200_24 630 x 100 mm 950 g 500030
22 W | 24 VDC | 2200 lm | neutral white | IP22 | 2 x 60 cm T8-tube | screw terminal
Ray Single 2200_24 1,240 x 80 mm 1150 g 500031
22 W | 24 VDC | 2200 lm | neutral white | IP22 | 1 x 120 cm T8-tube | screw terminal
Ray Twin 4400_24 1,240 x 100 mm 2200 g 500032
Loads
44 W | 24 VDC | 4400 lm | neutral white | IP22 | 2 x 120 cm T8-tube | screw terminal
Generators
LED Lighting Panel Square Light
Phaesun Square Panel are compact LED
lighting units for 24 VDC applications.
The stable PMMA housing means that it
Electronics
is unbreakable and can be used almost
anywhere. They are an optimum solution for
use in remote locations due to their very long
service life that makes replacement once in a
0DGHLQ
blue moon. *HUPDQ\
Batteries
Features:
Long life high intensity LEDs: optimum
performance and extended life.
Ultra versatile the 522 mm length strip consists
Loads
of 24 x high intensity LEDs, doubling to 48 LEDs
for the 1022 mm length strip, which have a
180 spread of light that will illuminate even the
darkest corners. The Orizon has been launched for
illuminating lockers, racking, steps and all interior
lighting applications.
Simple and easy to install e.g.simply using an
adhesive strip or fixing with clips or brackets (fixing
methods not supplied).
lighting solution.
Features:
Long life high intensity LEDs: optimum
performance and extended life.
Robust and easy to install
Features:
Increased product life to over 60.000 hours.
Easy installation set in a low profile tough
aluminium housing making it suitable for
both new vehicle specifications and retro
fitting into existing vehicles.
Tough aluminium housing the extruded
profile provides rigidity and strength but
keeps weight to a minimum, and the
annodised finish protects against corrosion.
Generators
Microlux and Superlux LED Lighting Units
The Microlux and Superlux utilises high powered
LEDs, with a 90 degree viewing angle. It excels
in a van environment due to its price tag and
Electronics
performance, but is also effective in larger
vehicles.
Batteries
LEDs that draw very little power, and with
the addition of an advanced crater reflector.
The design of the light is both aesthetic and
practical. The slim profile means the Powerlux
can be installed with minimum intrusion into
Loads
the load area and the extruded fins allow
maximum heat dissipation without the light
getting hot.
Features:
Power supplying at 12 V or 24 VDC
Luminous efficency: 80 lm/W
Opening angles: 90 V 140 H
IP65 Made in
Europe
Batteries
LED Spot Light for Billboard 355 x 150 x 270 mm 4,0 kg 360074
36 LED lamps | 36 W | 12/24V | 2700 lm | mounting bracket
Compact
Generators
Fluorescent Lamps
Electronics
Solsum ESL
The electronics of these 12 VDC energy-saving compact fluores-
cent lamps (CFLs) were developed by Steca and continuously
improved. Preheating, a high electronic efficiency and low
thermal losses increase the service life of these CFLs to about
100.000 switch cycles. The Steca energy-saving lights feature a
much higher efficiency (Im/W) than incandescent bulbs.
Batteries
Solsum ESL 5
Solsum ESL 5 (yellow) 55 x 123 mm 125 g 101406
5 W | 12 VDC | 250 lm | warm white | E27
Solsum ESL 5 (white) 55 x 123 mm 125 g 101407
5 W | 12 V DC | 250 lm | cool white | E27
Loads
Solsum ESL 5 (white B22) 55 x 123 mm 125 g 101408
5 W | 12 VDC | 250 lm | cool white | B22d
Solsum ESL 7
Solsum ESL 7 (yellow) 55 x 133 mm 125 g 101403
7 W | 12 VDC | 370 lm | warm white | E27
Solsum ESL 7 (white) 55 x 133 mm 125 g 101404
7 W | 12 VDC | 370 lm | cool white | E27
Solsum ESL 7 (white B22) 55 x 133 mm 125 g 101405
7 W | 12 VDC | 370 lm | cool white | B22d
Solsum ESL 11
Solsum ESL 11 (yellow) 55 x 163 mm 135 g 101400
11 W | 12 VDC | 650 lm | warm white | E27
Solsum ESL 11 (white) 55 x 163 mm 135 g 101401
11 W | 12 VDC | 650 lm | cool white | E27
Solsum ESL 11 (white B22) 55 x 163 mm 135 g 101402
11 W | 12 VDC | 650 lm | cool white | B22d
Refrigerators and
Generators
Freezer Boxes
Electronics
Generators
Solar Fridge
The Steca solar fridge product generation with
highest energy efficiency is perfectly optimized
for the use in solar applications. The new
Electronics
A++ DC fridge generation realizes a complete
concept. Best isolation combined with a very
efficient and silent DC compressor which is
driven by a specially designed Steca electronic
compressor regulation guarantee an optimum
use of the available solar power within the
system. Optionally the Steca solar fridge
coolers can be equipped with one of the well
known Steca Solar charge regulators which
interact optimally with the fridge functionality.
In this case just a suitable battery and the
solar module has to be connected to the Steca
solar fridge to start cooling. Especially the
Steca solar fridge as a top opener is optimally
suited for applications under high ambient
Batteries
temperature as it protects the content of the Made in
fridge also while the cabinet is open. Europe
Loads
166 l | 12/24 VDC
Solar Fridge/Freezer PF240 1288 x 760 x 919 mm 62 kg 360012
240 l | 12/24 VDC
Features:
Battery free operation
Electronics
WHO Standard!
Batteries
Generators
Vaccine Refrigerator Boxes
RCW and TCW Series
Compression refrigerators, freezers and ice
liners are made of rotomoulded polyethylene.
Electronics
These products are really robust for intensive
use. 100 mm polyurethane foam and silicon
gasket provide optimal insulation allowing an
operating temperature range 0 43 C.
RCW42 and RCW50 as well as TCW2000 has
separate compartments, each for refrigerating RCW 42 DC
RCW 50 DC
vaccines and freezing icepacks.
TCW3000 exists as icelined vaccine refrigerator.
The same model is available as a vaccine
freezer. A preset setpoint of 20 C can be
changed by a technician.
Batteries
TCW 3000 DC
WHO Standard! TCW 2000 DC
Loads
Vaccine Refrigerator RCW 42 DC 500 x 550 x 920 mm 43 kg 360045
vaccine 14 l & ice 2,4 l | battery 12/24 VDC | R134a | 0,61 kWh/d
Vaccine Refrigerator RCW 50 DC 830 x 720 x 980 mm 71 kg 360046
vaccine 24 l & ice 2,4 l | battery 12/24 VDC | R134a | 0,46 kWh/d
TCW Series | Battery driven
Vaccine Refrigerator TCW2000 DC BL53 POS 1270 x 790 x 910 mm 121 kg 360049
vaccine 76 l & ice 15,6 l | battery 12/24 VDC | R134a | 0,99 kWh/d
Vaccine Refrigerator TCW3000 DC 1280 x 780 x 900 mm 115 kg 360047
vaccine 110 l or ice 48 l | battery 12/24VDC | R134a | 1,82 kWh/d
DC Fans
Electronics
3 blades | 12 VDC | 6 steps | with remote control | max. speed 240 rpm | air delivery 12165 m/h
Loads
Generators
Electronics
Table Fan Fast Breeze
The highly efficient electronically commutated
motor allows for the lowest energy consump-
tion with the highest fan efficiency. The table
fan Fast Breeze with an automatic swivelling
drive including three speed levels is both
suited for offices and living rooms, but also for
production halls or when you travel.
speed level
1 2 3
switch
power 2,7 W 5,3 W 10,4 W
Batteries
air-flow 370 m3/h 580 m3/h 720 m3/h
Loads
DC Televisions
Electronics
Generators
Electronics
R-Line
The R-line convinces with equipment that offers
everything and the dimensions at least. The highlight
is the integrated alphatronicsPlay Bluetooth module. It
enables wireless connection of speaker systems from
alphatronicsPlay product line.
The integrated triple tuners offer a DVB-T MPEG-4, and
DVB-S2 tuner with CI + slot for pay TV. Furthermore
integrates a DVB-C tuner to connect to your digital
cable. By the MPEG 2 MPEG 4 standard + the Triple
tuner you receive high definition television (HDTV
Television) without restrictions. In addition, the R-Line
Batteries
features a DVD player (slide in on the right side),
USB port, HDMI port, and a power switch. The PVR
function is upgradeable via software update.
Loads
digital DVB-T antenna
(common in most European and African countries)
analog television antenna
or satellite
Electronics
Grundfos Pumps p. 224
Batteries
Loads
Pumps
223
Kits
Pumps Grundfos Pumps
Generators
Grundfos Pumps
Electronics
SQFlex Pumps
Installing the SQFlex Solar requires no special tools as
the solar modules plug straight into the system. The
SQFlex Solar can be run economically and remains
virtually maintenance-free. SQFlex pumps have built-in
protection features such as:
Protection against dry-running, overloading and
overheating
Automatic restart when water returns to the well
or when the motor temperature returns to the
safety range Float switch 5 m, p. 279
Continuous load condition and voltage monitoring
Batteries
30 300 VDC or 90 240 VAC | 50/60 Hz | 1,4 kW | 8,4 A | max. height 200 m | max. flow rate 0,6 m/h
Submersible Pump SQ Flex 1.2-2 74 x 1225 x Rp 1 mm 7,9 kg 102318
30 300 VDC or 90 240 VAC | 50/60 Hz | 1,4 kW | 8,4 A | max. height 120 m | max. flow rate 1,2 m/h
Submersible Pump SQ Flex 1.2-3 74 x 1295 x Rp 1 mm 8,2 kg 370017
30 300 VDC or 90 240 VAC | 50/60 Hz | 1,4 kW | 8,4 A | max. height 250 m | max. flow rate 1,1 m/h
Submersible Pump SQ Flex 2.5-2 74 x 1247 x Rp 1 mm 8,2 kg 102342
30 300 VDC or 90 240 VAC | 50/60 Hz | 1,4 kW | 8,4 A | max. height 120 m | max. flow rate 2,5 m/h
Submersible Pump SQ Flex 3A-10 101 x 968 x Rp 1 mm 9,5 kg 102268
30 300 VDC or 90 240 VAC | 50/60 Hz | 1,4 kW | 8,4 A | max. height 70 m | max. flow rate 5 m/h
Submersible Pump SQ Flex 5A-3 101 x 821 x Rp 1 mm 8,1 kg 102343
30 300 VDC or 90 240 VAC | 50/60 Hz | 1,4 kW | 8,4 A | max. height 15 m | max. flow rate 7 m/h
Submersible Pump SQ Flex 5A-7 101 x 905 x Rp 1 mm 8,8 kg 102344
30 300 VDC or 90 240 VAC | 50/60 Hz | 1,4 kW | 8,4 A | max. height 50 m | max. flow rate 7 m/h
Generators
Article Dimensions [l x w x h] Weight Article No.
Submersible Pump SQ Flex 8A-3 101 x 927 x Rp 1,2 mm 9,5 kg 102345
30 300 VDC or 90 240 VAC | 50/60 Hz | 1,4 kW | 8,4 A | max. height 15 | max. flow rate 13 m/h
Submersible Pump SQ Flex 14A-3 101 x 975 x Rp 2 mm 11,0 kg 102346
Electronics
30 300 VDC or 90 240 VAC | 50/60 Hz | 1,4 kW | 8,4 A | max. height 15 m | max. 16 flow rate m/h
Submersible Pump SQ Flex 8A-5 101 x 1011 x Rp 2 mm 10,5 kg 102266
30 300 VDC or 90 240 VAC | 50/60 Hz | 1,4 kW | 8,4 A | max. height 30 m | max. flow rate 13 m/h
Submersible Pump SQ Flex 11A-3 101 x 982 x Rp 2 mm 10,9 kg 102267
30 300 VDC or 90 240 VAC | 50/60 Hz | 1,4 kW | 8,4 A | max. height 15 m | max. flow rate 16 m/h
Batteries
fail. Although the initial investment including solar panel is
higher, the operating cost is minimal. For the CR-Flex surface
pump Grundfos has developed the MGFlex motor for optimal
performance using solar power, for surface pump applications.
Loads
Float Switch 5 m, p. 279
Cables for drinking water applications, p. 279
Pump accessories, p. 282 Made in
Europe
Pumps
Article Dimensions [l x w x h] Weight Article No.
Impeller made of stainless steel 1.431, other media contacting parts in 1.4401
Surface Pump CRIF 1-9 122 x 585 mm 26,3 kg 370039
0,75 kW | 50/60 Hz | 30 300 VDC | 1 x 90 240 VAC | rated flow 2,2 m/h | rated head 58,7 m | IP55
Surface Pump CRIF 3-5 122 x 513 mm 24,0 kg 370041
0,75 kW | 50/60 Hz | 30 300 VDC | 1 x 90 240 VAC | rated flow 3,5 m/h | rated head 34 m | IP55
Surface Pump CRIF 5-2 122 x 477 mm 21,6 kg 370040
0,75 kW | 50/60 Hz | 30 300 VDC | 1 x 90 240 VAC | rated flow 6,9 m/h | rated head 12,2 m | IP55
Surface Pump CRIF 10-1 200 x 357 mm 33,7 kg 370043
0,75 kW | 50/60 Hz | 30 300 VDC | 1 x 90 240 VAC | rated flow 12,1 m/h | rated head 10 m | IP55
Surface Pump CRIF 1-17 200 x 373 mm 40,0 kg 370038
1,5 kW | 50/60 Hz | 30 300 VDC | 1 x 90 240 VAC | rated flow 2,2 m/h | rated head 111 m | IP55
1,5 kW | 50/60 Hz | 30 300 VDC | 1 x 90 240 VAC | rated flow 6,9 m/h | rated head 45 m | IP55
Surface Pump CRNF 10-2 200 x 373 mm 40,0 kg 370024
1,5 kW | 50/60 Hz | 30 300 VDC | 1 x 90 240 VAC | rated flow 12,1 m/h | rated head 22,9 m | IP55
Surface Pump CRNF 15-1 200 x 413 mm 41,0 kg 370051
Pumps
1,5 kW | 50/60 Hz | 30 300 VDC | 1 x 90 240 VAC | rated flow 18 m/h | rated head 15,4 m | IP55
Generators
Shurflo Pumps
Electronics
Submersible Pump 9300
These pumps are designed to be strong and
lightweight. Typical applications include drip irrigation,
stock and wildlife watering, remote homes and cabins.
For shallow wells a pump controller should be used.
Features:
Water blocked electrical connector
Strong, yet lightweight
Corrosion proof housing with stainless-steel fasteners
Dry running capability without pump damage
Batteries
Internal bypass feature for pump protection
Technical Specifications:
Positive displacement 3 chamber diaphragm pump
Motor: Permanent magnet, thermally protected
Loads
24 VDC, 4,1 A maximum.
Internal bypass:7,2 7,5 bar
Maximum lift: 70 meters
Maximum submersion: 30 meters
Outlet port: 1/2" (12,7 mm) barbed fitting
Pumps
Inlet: 50 mesh stainless steel screen
12 VDC | 30 m | 10 l/min | 2,8 bar water pump | 7 A | 1/2 MPT port threads
Premium 2088-514-145 300 x 150 x 130 mm 6,5 kg 102336
12 VDC | 30 m | 13,5 l/min | 3,5 bar water pump | 6 A | 1/2 MSPT port threads
Sealed Premium 2088-713-534 200 x 120 x 100 mm 5,0 kg 370030
12 VDC | 30 m | 13,5 l/min | 2,8 bar water pump | 6 A | 1/2 MSPT port threads
Pumps
Generators
Pump accessories
We offer a wide portfolio of pump accessories from quality manufacturers. We use them for
perfectly fitting pumping systems. Find pump accessoreis on page 279 and following. More
pump accessories are available on request. Ask our sales team for more information!
Electronics
Pump Accessories, p. 279
ON
REQUEST
Batteries
Loads
Pumps
Electronics
& Spares
Kit Accessories p. 232
Batteries
Installation Material p. 283
Loads
Pumps
Accessories
231
Kits
Accessories & Spares Kit Accessories
Generators
Kit Accessories
Electronics
NEW Accessories
for Niwa Modular Solar Systems
The modular Niwa solar systems can be easily
extended to increase the usable output power
or enlarging capacity. System size will grow
with load consumption. PV power and battery
capacity can be plugged to the existing
system. LED Lamp Home
Batteries
Modular Solar System Upgrade X2 Kit 345 x 210 x 70mm 1,3 kg 350095
Storage Pack Energy X2 | USB Hub | Solar X3 | module extension cable | 5 x mobile phone adapters
AC/DC Converter Power Supply Unit 130 x 100 x 46 mm 52 g 321291
5 V USB | 1 A | 100 240 VAC | 50 60 Hz | phone charge adapter
Solar Module Solar X3 5 W 320 x 210 x 27 mm 660 g 310194
5 W | 5 VDC | DC-plug | poly | 4 m cable
Generators
Electronics
USB Accessories
Phaesun offers a variety of accessories to expand the Pico Kits.
NEW
USB Phone
Charging Set Pico USB Extension Dual USB Car Charger
Batteries
USB Phone Charging Set 70 g 390335
Sony Ericsson, Nokia, Mini- and Micro USB | 2 m | USB plug | changeable adapters
Pico USB Extension with 3 m cable 390341
NEW Dual USB Car Charger 45 x 25 x 26 mm 10 g 350090
5 V USB out | 2,1 A | 12 VDC in | white
Loads
Use these accessories for:
Niwa Kits, p. 24
Energy Comfort Kits Solar Side, p. 35
Pumps
Phocos Charge Controllers, p. 97
Duo Solar Charge Controller
Smart Duet, p. 99
Accessories
The Joulite can be simply slipped onto a USB-charging cable The integrated Joulite
filled bottle by means of the Bottle Holder accumulator can be used to charge small
Electronics
and then be used as a table lamp. electrical applications (e.g. Smart Phone).
Solar Module LEC30 with 5 V voltage Mobile phone charging cables for various
suitable for charging the Joulite. standardised mobile phones.
Batteries
Generators
Electronics
JouleStick
The JouleStick is multifunctional energy pack
that can be charged from Ulitium or T-lite Wall Dock 3
Kits with the included charging cable or with With the Wall Dock 3 you can charge up to
the optional Wall Dock 3. The JouleStick 30 three JouleSticks at the same time. The dock
contains 30 kJ of energy (most small can be connected to a LEC50 Sundaya solar
mobile phones need approximately 30 kJ, module or an existing Ulitium or T-lite kit DC
smartphones need 50 60 kJ for a full charge). distribution network with the bayonet cable.
Batteries
Wall dock for Joule-Stick 30
Loads
Sundaya Solar Modules
These light-weight, high efficiency, mono crystalline modules can be
used as portable modules or can be fixed easily at a roof or wall. The
modules are part of the Ulitium Series. Due to their Plug-and-Play tech-
Pumps
nology the modules are suitable to extend the Sundaya Light Kits. The
DC bayonet plug can be easily put to the Hub4 junction box. Therefore
any Sundaya Kit can be extended according to the users needs with
more solar modules, T-lite and Ulitium lamps, JouleSticks etc.
Accessories
individual set according to your personal accessories offer opportunities for fixing and
needs and wishes. The variety of phone charging.
Generators
Article Dimensions [l x w x h] Weight Article No.
Accessories for T-lite and Ulitium
Lithium Battery Pack for T-lite | 16 Wh | 4000 mAh 80 g 390422
Lithium Battery Pack Ulitium | 16 Wh | 4000 mAh 100 g 303514
Electronics
Bayonet Apollo DC Socket (red) 60 x 50 mm 70 g 390424
Hanger for Ulitium and T-lite 30 g 390507
Installation Accessories
Bayonet Plug DC Cable 240 cm [L] = 240 cm 303127
Bayonet Plug DC Cable 480 cm [L] = 480 cm 303129
Hub4 Junction Box 80 x 37 mm 100 g 303131
Junction box for up to 4 bayonet plugs
Hub 5 Junction Box 80 x 37 x 19 mm 400 g 390568
Junction box for up to 5 bayonet plugs | 30 V | 0,5 A
Mini Panel Wall Mounting Bracket 1000 g 303507
For wall mounting of LEC solar modules
AC/DC Converter power supply unit [L] = 3 m 400 g 303503
Input: 90 265 VAC | output: 18 W
Accessories for JouleStick and Phone Stick
Batteries
DC Phone Charger Cable USB Female 9g 390906
DC Phone Charger Cable Sony Ericsson K750i 7g 390663
DC Phone Charger Cable Mini USB 6g 390729
DC Phone Charger Cable Micro USB Adapter Motorola 6g 390731
DC Phone Charger Cable Nokia 2,0 mm Adapter 4g 390732
Loads
DC Phone Charger Cable Nokia 3,5 mm Adapter 5g 390733
DC Phone Charger Cable Nokia 3,5 mm Adapter Female socket 7g 390734
DC Phone Charger Cable Samsung A288 Adapter 8g 390735
DC Phone Charger Cable iPhone (below Version 5) 9g 390736
DC Phone Charger Cable Motorola M300/Samsung SAM04 6g 390737
Pumps
Phone Stick
Phone Stick 70 x 22 mm 26 g 390745
8,3 Wh | 2200 mAh | input 16,5 20 VDC / 1 A | output 5 VDC / 0,5 A | IP22
Accessories
Generators
Generator Accessories
Electronics
Support Structures Mono Axial
The Phaesun Mono Axial Support Structures module on the ground or at a wall. The
One and Two are single module support package includes all the components (screws,
structures with flexible tilt angles. They etc.) for the assembly of the these structures.
are built under high quality standards and
designed for maximum durability and The Mono Axial One is designed for a range
corrosion resistance in all environmental of 5 Watt up to 110 Watt modules.
areas. These structures are made of aluminum
and therefore very lightweight products. It The Mono Axial Two is designed for a range
is designed for the mounting of one solar up to 150 Watt (max width 712 mm).
Batteries
Loads
Pumps
Support Structure Mono Axial One Support Structure Mono Axial Two
Accessories
Generators
Roof Mounting Units
Electronics
AVAIL-
ABLE ON
REQUEST
Roof Hook Roof Screw
M-Profile T-Profile
Assembly Structure
Batteries
Aluminium Profile U Brackets
Loads
Roof Hooks Frankfurter Pfanne Tiles Moduleclamp Middle T
Including stainless steel screw, self-locking nut. Middle clamp to fix two solar modules at the
profile bar.
Corrugated Sheet Roof Screw Fitting
Pumps
For connections between profile bar and Moduleclamp Side M
rafter, connecting plate, screws, nuts and Edge clamp to fix the solar module at the
blocking screw. profile bar.
Accessories
Ground Structure
Pumps
Generators
NEW Top of the Pole Structure PN SLB
This battery box can be positioned on any
pole with a diameter of 102 mm. Modules
can be mounted on this box (please order
Electronics
bracket separately) and adjusted to the local
solar altitude with a variable inclination. There
is sufficient space and electronic equipment
available for 1 x 150 Ah or 2 x 120 Ah.
Batteries
Loads
Pumps
Accessories
Features:
High resilient (TV-tested safety)
Very low weight
High resistance to ageing due
to high performance plastic
An increased layer provides optimal
ventilation and air circulation
to support the efficiency
No additinal cable bushing necessary
Compact screw faces ensure a high level of
water resistance
Centering grooves as an installation aid
Aerodynamic design
Batteries
Generators
NEW Spoiler Profil Clever Mount
The salt water resistant Clever Mount profiles with
2 mm wall thickness in aluminium or black design are
perfectly suited for the fixation of solar modules. Due to
Electronics
their design, these profiles are clearly more lightweight
than comparable profiles made of plastic and meet the
highest quality requirements.
Batteries
Roof Duct Water Proof & Water Tight
These roof ducts can be easily fixed by glueing
Glue Set Easy Bond, p. 247
with e.g. the Tec7 glueing sets.
Lubricant
Contact spray
Cleaning agent
Protecting agent
Article Weight Article No.
1 cartridge GT7 550 g 390838
200 ml
Cleaner TEC7
Degreases and cleans surfaces
Does not generate oxide films on light metals
Batteries
Generators
Glue Set Easy Bond
These glue sets are the perfect solution to fix module
mounting sets on many different surfaces such as caravans
or boats. TEC7 is a completely newly developed all-purpose
Electronics
polymere, both for sealing and glueing applications. TEC7
is extremely hard while remaining permanently flexible. Its
adhesion on almost any material is unrivalled even on humid
undergrounds. TEC7 sets very quickly and can be overcoated
instantly. TEC7 has an UV filter. It is
odourless, non-poisonous and free of
solvents, it isnt harmful to plastic materials.
Tensile strength: 265 N/cm. Thermal
stability: 30C to +95 C.Not suitable
for: PE, PP, silicone and some industrial
varnishes.
Batteries
Easy Bond Two 2,0 kg 390606
2 tubes TEC7 50 ml | 1 can TEC7 Cleaner 200 ml | for the fixation of two solar modules
Loads
Cartridge and glue gun
310 ml cartridge with glue gun available for an
increased demand of TEC7 adhesive.
Pumps
Accessories
Generators
Electronics Accessories
Electronics
NEW Remote Display Smart Duet
All functions of the Smart Duet Duo Charge Controller
can be displayed and programmed by means of the
remote control regardless of where the charge controller is
installed. The appealing yet plain designed remote control
fits perfectly in any living room and displays both the
current and past data numerically and graphically. You can 0DGHLQ
e.g. charge a Smart Phone directly via the USB output. *HUPDQ\
Batteries
Loads
Steca PA Shunt
Intelligent hall shunt with contactless current
sensor measuring. Potential free shunt with
RJ45 interface for communication with
Pumps
controllers for exact SOC calculation. Parallel
operation with several PA HS shunts is
possible.
Accessories
0DGHLQ
*HUPDQ\
Generators
Steca PA EV200 DC Relays
Steca PA EV200 relay increases the switching
capacity of the PA 15 remote control from 15 A to
200 A (up to 10 kW). The relay is connected to the
Electronics
load output of the PA 15 and interrupts for example,
the battery supply voltage from a back-up generator
when the battery is full. The relay is hermetically
sealed, intrinsically safe and operates in explosive &
harsh enviroments like salt, moisture and dust with
0DGHLQ
no oxidation or contamination of coils or contacts. *HUPDQ\
Batteries
Tarom) The PA 15 unit is able to receive the SOC
(state of charge) signal from the charge controller
and depending on the configuration it cuts off
loads or puts on additional generators. A charging
management is the second feature of the PA 15
Loads
receiver. The programming of the PA 15 is made 0DGHLQ
by a jumper connection terminal. *HUPDQ\
Pumps
15 A load current | 12/24/48 VDC
Generators
Morningstar Charge Controller Accessories
Electronics
TriStar Digital Meter TriStar Remote Digital Remote Temperature
TS-M-2 Meter TS-RM-2 Sensor Morningstar RTS
Batteries
MeterHub-1 RD-1
Loads
TriStar remote digital meter for use with TriStar and TriStar MPPT
Remote Temperature Sensor RTS 100 g 390618
compatible with TriStar, TriStar MPPT, ProStar, SunKeeper, SunSaver Duo, SunSaver MPPT
Junction Box MeterHub-1 135 x 108 x 37 mm 190 g 390654
Pumps
may be used with TriStar, TriStar MPPT, TS-M-2, TS-RM-2 or Relay Driver (RD-1)
Relay Driver RD-1 163 x 81 x 33 mm 200 g 390816
750 mA, 40C to +45C, compatible with TriStar, TriStar MPPT and all other controllers
Accessories
Studer RCC-02 Studer RCC-03 Studer BTS-01 Studer Cooling Fan Studer BSP
NEW
Generators
Studer Inverter/Charger Accessories
X-Connect System:
The X-Connect frame offers a flexible and
Electronics
cost effective solution for high power systems
based on XTH inverter.
Batteries
Loads
Studer AJ Accessories
Pumps
JT8 Remote Control
Remote control (ON/OFF) for Studer inverters
101310 101317.
Accessories
Studer RCC-01 Studer CT-35 Studer ARM-01 Studer CFC-01 Studer C-IP22
Outback Power Systems Accessories Find technical data on the next page.
Pumps
Generators
Article Dimensions [l x w x h] Weight Article No.
Load Center
Load Center GSLC175-230 591 x 520 x 337 mm 20,4 kg 390746
Prewired GSLC with 175 A inverter disconnects | 230 VAC inverter bypass and dual AC inputs
Electronics
Load Center GSLC175-PV-230 591 x 521 x 337 mm 21,3 kg 390747
Prewired GSLC with 175A inverter disconnects | GFDI and PV disconnects for two charge controllers |
FLEXnet DC W/3 shunts | 230 VAC inverter bypass and dual AC inputs
Communication
Mate3 178 x 190 x 44 mm 1,1 kg 390311
system supervision | parameter settings | monitoring | data logging | Ethernet | IP30
Mate Remote black 146 x 108 x 51 mm 454 g 107355
front panel | system supervision | parameter settings | monitoring | data logging | RS232 | IP30
PV Combiner Enclosure 341 x 224 x 86 mm 2,3 kg 107360
up to 12 OBPV breaker or 8 FHs
Hub 4 500 g 107312
collecting center for 10 Inverter or Flexmax plus1 Mate | cable included
Hub 10 500 g 107313
collecting center for 10 Inverter or Flexmax plus 1 Mate | cable included
DC Monitor System
Batteries
FLEXnet DC 19 x 95 x 179 mm 150 g 107701
DC Current Shunt FW-Shunt 500 302891
500 A | 50 mVDC current shunt for FX Series Inverter/Charger
DC Current Shunt FW-Shunt 250 302892
250 A | 50 mVDC current shunt for FX Series Inverter/Charger
Surge Protectors
Loads
FW-SP-ACA 215 x 172 x 64 mm 570 g 107702
FW-SP-250 139 x 165 x 190 mm 520 g 107703
FW-SP-R 197 x 139 x 38 mm 210 g 107704
Temperature Sensor
Pumps
Temperature Sensor 5,5 m 200 g 107359
Accessories
Phocos CIS CU
Configures CIS charge controllers via infra-red data link. Simple and
clear configuration interface with LEDs, rotary switches, toggle
switches, buttons. The CU can be used to confirure deep discharge
Electronics
threshold, dusk till dawn light control, light timer, dimming level upt to
a distance of 10 meters.
Article Dimensions [l x w x h] Weight Article No.
CIS CU 70 x 135 x 24 mm 150 g 320008
remote for CIS solar charge controller
Generators
SMA Sunny Island Multicluster Boxes
AC main distribution for off-grid and hybrid
systems in the power ranges of 20 to 300 kW
and a maximum PV output of 360 kW. Based
Electronics
on proven technology, 2 to 12 three-phase
clusters, each consisting of 3 Sunny Island
inverters 6.0H / 8.0H, can be connected in
parallel. To simplify installation, all Multicluster
Boxes are completely wired and fitted at
the factory and have a main connector for
generators, the load distribution and PV or
wind turbine systems. All data cables required
for the installation are included in the delivery.
Article Dimensions [l x w x h] Weight Article No.
Multicluster Box 6 760 x 760 x 210 mm 60 kg 330016
55 kW | up to 6 Sunny Island | IP65
Multicluster Box 12 1000 x 1400 x 300 mm 140 kg 330017
110 kW | up to 12 Sunny Island | IP54
Batteries
Multicluster Box 36 1200 x 2000 x 850 mm 300 kg 330018
300 kW | up to 36 Sunny Island | IP54
Loads
Sunny Island Multicluster System 13-phase
Modules
Pumps
Sunny Mini Central
Sunny Boy Sunny Tripower
AC Load
Accessories
MC Box
Generator
Sunny Island
6.0H, 8.0H
Batteries
Generators
SMA Piggy Backs
A full scope of communication products is
available for simple and easy performance
evaluation of your PV plant. These products are
Electronics
modular and can be put together nearly any way
one wants, resulting in a wide range of individual
SMA Piggy Back SMA Speedwire
monitoring concepts.
Article Article No.
Piggy Back SI-COMSMA-NR 105861
RS485 interface for Sunny Island SI 3.0M, SI4.4M, SI 6.0H, SI8.0H
Piggy Back DM-485CB-10 330022
RS485 interface for SBxx00TL, STP xx000TL
Speedwire SWDMSI-NR10 390769
Interface for Sunny Island SI 3.0M, SI4.4M, SI 6.0H, SI8.0H
Batteries
SMA Battery Temperature Sensor Battery temperature sensor type KTY
Loads
Article Dimensions [l x w x h] Weight Article No.
BatTempSensor Length: 10 m 1 kg 105860
with 10 m connection cable for Sunny Island. Spare part for SI 6.0H-11, 8.0H-11
Pumps
Accessories
Phaesun Connection/Junction Boxes components are selected for durable use and
The PN-GCB/GJB Generator Connection Boxes most comfortable installation. These products
and the PN-JB Junction Boxes are specially fulfill highest operational safety through
developed for use in professional photovoltaic main switch with two contacts in parallel to
Electronics
Made in
Europe
PN-GJB Box PN-GCB Box PN-JBI
Article Dimensions [l x w x h] Weight Article No.
PN-GJB Connection Boxes
Batteries
Generators
Battery Accessories
Electronics
NEW Battery Box HM318BK
Snap-Top battery boxes are manufactured
using the highest quality injection molded
polypropylene plastic.
Features:
Effectively collects electrolytes
Allows ventilation
Secures and locks lid to prevent accidental
contact of underground battery terminals
Resistant to Ultra-Violet (UV) exposure
Batteries
Article Dimensions [l x w x h] Weight Article No.
Battery Box HM318BK 448 x 254 x 267 mm 1,3 kg 391153
PP-plastic | inner size 368 x 200 x 248 mm | for batteries up to 110 Ah
Loads
Battery Boxes PN-Cab
Pumps
The PN-CAB range of battery boxes for Off-
Grid power and portable systems are designed
for an inside or outside installation. With a
comprehensive size range, they can be used with
Accessories
Including accessories!
Article Dimensions [l x w x h] Weight Article No.
Battery Box PN-CAB 680 1581 x 768 x 977 mm 38 kg 600014
Internal dimensions 1395 x 565 x 739 mm | IP23 | 680 l | polyethylene | passive air conditioning system
0DGHLQ
*HUPDQ\
Generators
NEW Electrolyte Circulation System Sun Air
The electrolyte circulation system pumps
ambient air to the bottom of each battery
cell. Emerging air bubbles rise through the
Electronics
electrolyte, ensuring a homogeneous electrolyte
density distribution in each cell. The system
is switched on and off automatically and is
virtually maintenance free. The system is easy to
install (plug & play), works independently and
can be retrofit to OPzS solar.power batteries.
For safe operation the system is equipped with
maintenance free pump motor and filter for
air intake.
Batteries
Sun Air 24 V OPzS 2540-2900 261,5 x 201 mm 1,5 kg 391107
OPzS solar.power 2540-2900 | pump ca. 0,6 A / 0,3 A in operation | volume flow 720 l / 100 mbar
Sun Air 24 V OPzS 3250-4700 261,5 x 201 mm 1,5 kg 391108
OPzS solar.power 3250-4700 | pump ca. 0,6 A / 0,3 A in operation | volume flow 720 l / 100 mbar
Sun Air 48 V OPzS 910-1820 261,5 x 201 mm 1,5 kg 391109
Loads
OPzS solar.power 910-1820 | pump ca. 0,6 A / 0,3 A in operation | volume flow 720 l / 100 mbar
Sun Air 48 V OPzS 2170 261,5 x 201 mm 1,5 kg 391110
OPzS solar.power 2170 | pump ca. 0,6 A / 0,3 A in operation | volume flow 720 l / 100 mbar
Sun Air 48 V OPzS 2540-2900 261,5 x 201 mm 1,5 kg 391111
OPzS solar.power 2540-2900 | pump ca. 0,6 A / 0,3 A in operation | volume flow 720 l / 100 mbar
Pumps
Sun Air 48 V OPzS 3250-4700 261,5 x 201 mm 1,5 kg 391112
OPzS solar.power 3250-4700 | pump ca. 0,6 A / 0,3 A in operation | volume flow 720 l / 100 mbar Accessories
Generators
Electronics
Battery Terminal Clamps Quick Power Battery Clamps Ford Terminal Adapter
Batteries
Plus/minus tin-plated brass
Quick-Power Battery Clamps 150 g 390545
Set plus/minus
Ford Terminal Adapter Set 390023
Positive/negative | round terminal on flat terminal
Loads
Degasing Hoses
Degasing hose 1730 [L] = 400 mm 5g 390322
Without backfire protection
Degasing hose 1300SF [L] = 400 mm 5g 390323
With backfire protection
Pumps
Vacuum Hand Pump
Vacuum hand pump for battery ccid PL6000 1,7 kg 390665
Vacuum hand pump with 6 l recipient, hose, sealing cap and charger
Terminal Adapters
Accessories
Battery Terminal Fuse Isolation Nut for Battery Terminal Battery Terminal
Pudenz CF 8 150A Fuses Pudenz CF 8 Isolation Cap1 Isolation Cap2
75 A 24 x 20 x 12 mm 10 g 390154
100 A 24 x 20 x 12 mm 10 g 390155
125 A 24 x 20 x 12 mm 10 g 390156
150 A 24 x 20 x 12 mm 10 g 303309
175 A 24 x 20 x 12 mm 10 g 390157
200 A 24 x 20 x 12 mm 10 g 390158
Loads
250 A 24 x 20 x 12 mm 10 g 390159
300 A 24 x 20 x 12 mm 10 g 390160
Insulating Nuts
Insulating Nut for Fuse Pudenz CF8 300 A 22 x 22 x 12 mm 12 g 303310
Pumps
Generators
Battery Fluid Acid 38 % H2SO4
Bottle with sulphuric acid 1000 ml acid 1,285 g/ml
with IMO dangerous goods declaration for road cargo
transport ADR/RID-GGVS/E class: 8, maritime transport
Electronics
IMDG/GGV Sea class: 8, air transport ICAO/IATA class:
8 ,UN/ID-No. 2796 DIN 43530.
Article Article No.
Battery Fluid Acid 38 % H2SO4 30 l 103748
Battery Fluid Acid 38 % H2SO4 1 l 108050
NH Fuses
NH Fuses with energised handlens, max. 500 V,
site class gL/gG (DIN VDE).
Batteries
Article Article No.
NH1 Fuse 40 A 303065
NH1 Fuse 80 A 303066
Loads
NH1 Fuse 100 A 303080
NH1 Fuse 125 A 303071
NH1 Fuse 160 A 303075
NH1 Fuse 200 A 303081
NH00 Fuse 125 A 303074
Pumps
NH000 Fuse 40 A 303072
NH000 Fuse 63 A 303068
NH000 Fuse 80 A 303070
NH000 Fuse 100 A 303069
Accessories
Acid Tester
Testing instrument for acid density
Generators
Disconnector Boxes
NH fuse enclosure with IP65 protection(when using
the corresponding cable glands) and transparent cover.
One NH-fuse disconnector can pull three NH fuses
Electronics
simultaneously. With two NH-fuses both battery poles
can be protected. Additionally one earthing clamp is
integrated as well.
0DGHLQ
*HUPDQ\
Batteries
Battery Testing Equipment
Loads
Results via Display Results via LCD-Display Results via LCD-Display
For 12 V batteries For 6 and 12 V batteries For 12 and 24 V batteries
40 cm cable 75 cm cable
Battery tongs Battery tongs
Pumps
Accessories
the battery from an allow to supply the auxiliary the charger or alternator
excessive discharge and also battery or the appliances, to several batteries. They
the consumers in case of as soon as the main battery generate an insignificant
overvoltage. voltage is high enough. voltage drop.
Connection and Insignificant voltage drop All batteries are thus charged
Loads
disconnection voltage Protect the auxiliary battery at the same time, and
programmed by jumpers from any overvoltage therefore will not change or
MOSFET switches, therefore discharge each other.
no sparks Automatic adjustment
Alarm output to indicate to the batteries volatge
Pumps
Generators
Electronics
Article Dimensions [l x w x h] Weight Article No.
Battery Watch MBW
Battery Watch MBW 40 80 x 60 x 40 mm 200 g 303571
40 A | 12/24 VDC | LVD12: 10 11,5 VDC | LVD24: 21,5 23 VDC
Battery Watch MBW 60 80 x 60 x 40 mm 200 g 303572
60 A | 12/24 VDC | LVD12: 10 11,5 VDC | LVD24: 21,5 23 VDC
Battery Watch MBW 200 145 x 92 x 85 mm 580 g 303573
200 A | 12/24 VDC | LVD12: 10 11,5 VDC | LVD24: 21,5 23 VDC
Battery Separator MBR
Battery Separator MBR 12/24-100 46 x 46 x 80 mm 110 g 390308
100 A | 12/24 VDC | 2 x battery
Batteries
Battery Separator MBR 12/24-160 46 x 93 x 96 mm 300 g 390309
160 A | 12/24 VDC | 2 x battery
Battery Separator MBR 12/24-500 72 x 70 x 80 mm 417 g 390310
500 A | 12/24 VDC | 2 x battery
Battery Splitter MBI
Battery Splitter MBI 100/2 146 x 85 x 92 mm 780 g 390459
Loads
100 A | 12/24 VDC | 1 x charger input | 2 x battery
Battery Splitter MBI 150/2 146 x 85 x 92 mm 810g 390913
150 A | 12/24 VDC | 1 x charger input | 2 x battery
Battery Splitter MBI 100/3 146 x 85 x 152 mm 780 g 390914
Pumps
100 A | 12/24 VDC | 1 x charger input | 3 x battery
Battery Splitter MBI 150/3 92 x 85 x 146 mm 780 g 390883
150 A | 12/24 VDC | 1 x charger input | 3 x battery
Battery Splitter MBI 200/3 146 x 85 x 152 mm 815 g 390915
200 A | 12/24 VDC | 1 x charger input | 3 x battery
Accessories
Generators
Load Accessories
Electronics
LED Tubes PN-OP for Replacement for Ray and Airtight
There is no flickering and cold start problem as known from CFLs.
Also switching on/off does not affect lifespan, such as CFLs. PN-OP
tubes are for replacement of PN-OP lamps or can be used as
lighting unit just in combination with PN clip sets.
Batteries
Clip-Set for PN-OP LED Tubes
Loads
The most simple lighting installation is the PN-OP LED
light tube in combination with these clip sets. Create
your own efficient 24 VDC lighting unit!
Pumps
Article Dimensions [l x w x h] Weight Article No.
Clip-Set for LED Tubes 4g 500026 Accessories
Generators
LED Driver Phocos CIS-DR
Features:
Specially designed for solar street lights and
Electronics
applications in demanding environments
Robust fully protected case (IP67)
Buck/boost converter for a wide LED string voltage
range, for all standard industry LED blocks
External temperature sensor and soft-start enhanced
for a longer LED lifetime
Linear or true-color PWM LED dimming output for
professional rue color dimming
Small size fits in most applications
Article Dimensions [l x w x h] Weight Article No.
LED Driver CIS-DR-LC 89 x 42 x 112 mm 625 g 321158
Output 2 54 VDC | 350 mA, 550 mA, 700 mA | input 12/24 VAC | 3,5 A
LED Driver CIS-DR-MC 89 x 42 x 112 mm 625 g 321159
Output 2 54 VDC | 1050 mA, 1400 mA, 1750 mA | input 12/24 VAC | 6,5 A
Batteries
LED Driver CIS-DR-HC 89 x 42 x 112 mm 625 g 321157
Output 2 54 VDC | 2100 mA, 2450 mA, 2800 mA | input 12/24 VAC | 6,5 A
Loads
Pumps
Accessories
Sound System
Alphatronics Play2 Bluetooth 2.0
Bluetooth 2.0 This high-quality system offers
stereo sound with high-end loudspeakers.
Electronics
consumption.
Generators
Pump Accessories
Electronics
Float Switch
This float switch ensures reliable control of a pump or
solenoid valve. If the set liquid level is exceeded, the
switch activates the connected unit; when the set height
is reached, it switches off again (full pumping). You set
the level by adjusting the float connector cable length.
Batteries
Cables for Drinking Water Applications
For the permanent use in potable water, connecting
electrical apparatus, e.g. submersible pumps up to
temperature of 70 C and up to 400 m immersion depth.
Loads
Article Dimensions [l x w x h] Weight Article No.
Submersible Pump Cable 3G1,5 mm blue 9,7 mm 135 g/m 102325
600/1000 VAC
Submersible Pump Cable 3x 2,5 mm blue 11,4 mm 210 g/m 102333
Pumps
600/1000 VAC
Submersible Pump Cable 3G 4 mm blue 13,0 mm 280 g/m 102479
600/1000 VAC
Submersible Pump Cable 3G 6 mm blue 14,5 mm 370 g/m 102319
600/1000 VAC
Accessories
Pass 3 x 1,5 to 5 x 6 mm
Lateral 3 x 1,5 to 5 x 4 mm
Hardener 0,225 kg
Incl. sleeve, polyurethane cast-resin, hardener,
Pumps
Generators
2" Rylbrun 20 Hoses
Rylbrun 20 flexible pipe made of polyurethane with
polyester textile internal reinforcement. It is supplied
with electrical cable attachment bands. Perfectly
Electronics
fitted for submersible pumps Due to its dilatation
it is optimal for high powered pumps installation
diminishing pressure loss.
Batteries
Loads
Wellhead Plate Kit
Wellhead plate 5 mm galvaized steel for
borehole including accessories: cable gland
& locknuts 25 x 1,5 mm with 4 x anchor pins
10 x 93mm 30 x 30 cm with hole 2 bow 90
Pumps
2 double thread nipple 2 niro bushings.
Generators
Installation Material
Electronics
Cable Solarflex
Single solar cables double isolated and robust
against mechanical impacts. VDE and TV
approved and RoHS conform. UV, Ozone,
weather and flame-resistant. Very robust and
abraison-resistant.
Double isolated 1000 VAC 1500 VDC for a
wide temperature range 40 C to +90 C.
Batteries
Cross section 2 x 2,5 mm | cable diameter 4,5 mm
Solarflex-X-PV1-F 1 x 2,5 mm red 42 g/m 303586
Cross section 2 x 2,5 mm | cable diameter 4,5 mm
Solarflex-X-PV1-F 1 x 2,5 mm blue 42 g/m 303587
Cross section 2 x 2,5 mm | cable diameter 4,5 mm
Loads
Solarflex-X-PV1-F 1 x 4 mm black 60 g/m 303588
Cross section 2 x 4 mm | cable diameter 5,2 mm
Solarflex-X-PV1-F 1 x 4 mm red 60 g/m 303589
Cross section 1 x 4 mm | cable diameter 5,2 mm
Solarflex-X-PV1-F 1 x 4 mm blue 60 g/m 303590
Pumps
Cross section 1 x 4 mm | cable diameter 5,2 mm
Solarflex-X-PV1-F 1 x 6 mm black 82 g/m 303591
Cross section 1 x 6 mm | cable diameter 5,9 mm
Solarflex-X-PV1-F 1 x 6 mm red 82 g/m 303592
Accessories
The already proven conductor type is completed with ready-made solar wires and
offered under the individual brand of special designs as individual solutions for
SOLARFLEX-X PV1-F, approved by VDE, customers together with a wide range of
TV and UL, also with rodent protection accessories including sockets, connectors,
included on request. The programme is adapters and tools.
Generators
Electronics
Cable lflex Solar XLS-R Twin BK/RD
Twin Solar Cable separable cross-linked by resistant. Good notch and abrasion resistance.
electron beam. Easy to split into two separate Double isolated 1000 VAC 1500 VDC.
cables. Robust against mechanical impacts. Fixed installation: 40 C to +100 C max.
Especially designed for confortable installation conductor temperature.
in junction boxes. UV, weather and ozone
Batteries
Cable lflex Solar XLS-R Twin 2 x 6 BK/RD 174 g/m 390924
Cross section 2 x 6 mm | cable diameter 5,8 mm
Loads
Pumps
Accessories
Generators
Rubber Sheathed Cables H07RN-F
Heavy duty rubber-sheathed flexible cables are suited
for use for medium mechanical stress in dry, damp
and wet areas as well as in open air and in agriculture
Electronics
plants. The H07RN-F Cable is intended for installations
with moving equipment, electric appliances and
for building sites. This cable can be used in wide
temperture range 30 C to +60 C. Ozone, weather
and flame-resistant with very good resistance to oils
and chemicals. Isolation voltage up to 1000 V.
Batteries
Cross section 1 x 10 mm | cable diameter 9,5 11,9 mm
Cable H07 RN-F 1 x 16 mm 290 g/m 103206
Cross section 1 x 16 mm | cable diameter 10,8 13,4 mm
Cable H07 RN-F 1 x 25 mm 420 g/m 103207
Cross section 1 x 25 mm | cable diameter 12,7 15,8 mm
Cable H07 RN-F 1 x 35 mm 530 g/m 103215
Loads
Cross section 1 x 35 mm | cable diameter 14,3 17,9 mm
Cable H07 RN-F 1 x 70,0 mm 960 g/m 103231
Cross section 1 x 70 mm | cable diameter 18,6 23,3 mm
Cable H07 RN-F 2 x 1,0 mm 98 g/m 106252
Pumps
Cross section 2 x 1,0 mm | cable diameter 7,7 10 mm
Cable H07 RN-F 2 x 2,5 mm 193 g/m 103208
Cross section 2 x 2,5 mm | cable diameter 10,2 13,1 mm
Cable H07 RN-F 2 x 4 mm 280 g/m 103209
Accessories
Generators
Earthing Material
Electronics
Earthing Cable Kit with Ring Earthing Kit 25 m Earthing Rod Kit 1500 m
Terminals
Batteries
Loads
Pumps
Accessories
QY-1 QYD-2 Bus Bar 2p13 CBI QDC Bus Bar 4p19
Features
UL 489 A listed
DIN rail mounting
100 % rating capability
Hydraulic-magnetic technology
Generators
DC Installation Components
The equipment has been developed for all times. Consequently the plug has one thick
solar powered (battery) installations, rating and one thin pin making the polarity un-
from 12 to 48 VDC. 10 A 2 pole, no earth. mistakeable. Suitable equipment onboard for
Electronics
The socket outlet cover plates are made of e.g. boats, yachts, campers, cottages etc. and
thermosetting plastic. This DC equipment is areas without fully built-out electrical network
totally polarized, e.g. the plug will fit only one that are dependant on rechargable batteries
way in the outlet, assuring correct polarity at based on solar energy.
DC Toggle Switch Drop Light Fitting E27 DC Double DC Flush Type Double
Surface Socket Surface Socket
Batteries
Loads
DC Plug No Earth DC Junction Box Single Wall AC Socket AC Toggle Switch
Broco Switch
Pumps
DC Installation Material
Toggle Switch 63 x 63 x 36 mm 86 g 103734
Up to 230 VAC and 10 A
Droplight Fitting E27 | 12 VDC | 80 cm | cable white 95 g 107219
Accessories
Phaesun DC Installations
DC Double Surface Socket 12 48 VDC 95 x 62 x 25 mm 86 g 103710
DC Flush Type Double Surface Socket 12 48 VDC 95 x 85 x 30 mm 104 g 103711
DC Plug No Earth 12 48 VDC 36 x 45 mm 23 g 103712
DC Junction Box 65 x 50 x 29 mm 40 g 103713
Switches
Single Wall Broco Switch | on/off switch 60 x 60 x 50 mm 50 g 101793
AC Installation Material | splash proof
AC Socket 74 x 50 x 74 mm 30 g 390035
Toggle Switch 74 x 74 x 54 mm 86 g 390711
Junction Box
Junction Box for surface mounting in damp
zones. Easy mounting, including 12 cut-off
self-sealing line entrances ensure subsequent
Electronics
adjustments.
Luster Terminals
12 pole. Clamps brass, screws made of
Distribution Box steel, galvanised and captive; single clamps
separable from bar; heat resistant up to
100 C, VDE certification; glow wire test
Luster Terminals 850 C, material polypropylene.
Junction Box
Junction Box HJB1010 (100 x 100 x 40 mm) | surface mounting | IP54 390106
Distribution Box
Distribution Box 2U1R-Sch | 2 units | 1 row | without flap lid | IP40 390819
Distribution Box 3U1R-Sch | 3 units | 1 row | flap lid | IP55 390907
Luster Terminals
Loads
Generators
Electronics
Tools, p. 222
Batteries
pack includes 100 pieces.
Loads
Ring Terminal HR2M5 | cross section 0,5 1 mm | connecting bolt 5 mm | red 100 390037
Ring Terminal HR2M6 | cross section 0,5 1 mm | connecting bolt 6 mm | red 100 390038
Ring Terminal HR3M4 | cross section 1,5 2,5 mm | connecting bolt 4 mm | blue 100 390039
Ring Terminal HR3M5 | cross section 1,5 2,5 mm | connecting bolt 5 mm | blue 100 390040
Pumps
Ring Terminal HR3M6 | cross section 1,5 2,5 mm | connecting bolt 6 mm | blue 100 390041
Ring Terminal HR3M8 | cross section 1,5 2,5 mm | connecting bolt 8 mm | blue 100 390042
Ring Terminal HR5M4 | cross section 4 6 mm | connecting bolt 4 mm | yellow 100 390043
Ring Terminal HR5M5 | cross section 4 6 mm | connecting bolt 5 mm | yellow 100 390044
Ring Terminal HR5M6 | cross section 4 6 mm | connecting bolt 6 mm | yellow 100 390045
Accessories
Ring Terminal HR5M8 | cross section 4 6 mm | connecting bolt 8 mm | yellow 100 390046
Ring Terminals
Ring Terminal 572R6 | cross section 6 10 mm | connecting bolt 6 mm | 2 screws 10 391114
Ring Terminal 573R8 | cross section 10 16 mm | connecting bolt 8 mm | 2 screws 10 391115
Ring Terminal 584R8 | cross section 16 25 mm | connecting bolt 8 mm | 4 screws 10 391116
Ring Terminal 585R8 | cross section 25 35 mm | connecting bolt 8 mm | 4 screws 10 391117
Ring Terminal 586R10 | cross section 35 50 mm | connecting bolt 10 mm | 4 screws 10 391118
Ring Terminal 587R10 | cross section 50 70 mm | connecting bolt 10 mm | 4 screws 10 391119
Ring Terminal 588R10 | cross section 70 95 mm | connecting bolt 10 mm | 4 screws 10 391120
required and when you have big cable diameters. and following
and following
conductors; fan-out and damage prevention.
Wire End HAE075 | cross section 0,75 mm | pin length 8 mm | grey 100 pcs 390048
Wire End HAE1 | cross section 1 mm | pin length 8 mm | red 100 pcs 390049
Wire End HAE15 | cross section 1,5 mm | pin length 8 mm | black 100 pcs 390053
Wire End HAE25 | cross section 2,5 mm | pin length 8 mm | blue 100 pcs 390055
Wire End HAE4 | cross section 4 mm | pin length 10 mm | grey 100 pcs 390050
Wire End HAE6 | cross section 6 mm | pin length 12 mm | yellow 100 pcs 390051
Wire End HAE10 | cross section 10 mm | pin length 12 mm | red 100 pcs 390052
Wire End HAE16 | cross section 16 mm | pin length 12 mm | blue 100 pcs 390054
Wire End HAE250 | cross section 25 mm | pin length 16 mm | yellow 100 pcs 390056
Wire End HAE350 | cross section 35 mm | pin length 16 mm | red 100 pcs 390057
Generators
Cable Straps PVC Insulating Tapes
The cable straps are made of polyamide PVC insulating tape;
6.6. Service temperature: 40 C to +85 C 10 m x 15 mm x 0,15 mm according to
(up to +105 C for a short time). Technical DIN EN 60454-3-1; various colours.
Electronics
adjustments reserved. One pack includes
100 pieces.
Batteries
Cable Strap HKB20436B | L x B 204 x 3,6 mm | UV resistant | 133 N 100 pcs 390084
Cable Strap HKB22647B | L x B 226 x 4,7 mm | UV resistant | 222 N 100 pcs 390085
Cable Strap HKB29036B | L x B 290 x 3,6 mm | UV resistant | 133 N 100 pcs 390086
Cable Strap HKB29147B | L x B 291 x 4,7 mm | UV resistant | 356 N 100 pcs 390087
Cable Strap HKB37576B | L x B 375 x 7,6 mm | UV resistant | 667 N 100 pcs 390088
Loads
Cable Strap HKB36647B | L x B 366 x 4,7 mm | UV resistant | 356 N 100 pcs 390089
PVC Insulating Tapes
PVC Insulating Tape HET1015C | blue 390079
PVC Insulating Tape HET1015F | red 390080
PVC Insulating Tape HET1015YG | green/yellow 390081
Pumps
Accessories
A4 stainless steel.
Generators
QuickCab QuickClip
Phaesun QuickCab cables are prefabricated Phaesun QuickClip for safe, waterproof and
extension kits in different length. QuickCab3 simple parallel connection of solar modules.
is compatible with commercial 3 mm Y-Adapter QuickClip3 is compatible with
Electronics
and QuickCab4 with 4 mm PV-connector commercial 3 mm and QuickClip4 with 4 mm
(Standard3 and Standard4).QuickCab is an UV PV-connector (Standard3 and Standard4).
resistant and waterproof connection between
solar modules and charge regulator.
Batteries
QuickCab4-4/5 | Standard4 | 2 x 4 mm 5m 500041
QuickCab4-4/10 | Standard4 | 2 x 4 mm 10 m 500042
QuickCab4-6/5 | Standard4 | 2 x 6 mm 5m 500043
QuickCab4-6/10 | Standard4 | 2 x 6 mm 10 m 500044
QuickCab3-2,5/5 | Standard3 | 2 x 2,5 mm | for PN-SPR Solar Modules 5m 390354
Loads
QuickClip
QuickClip3 Set LU | Standard3 | 1 x male-female-female | 1 x female-male-male | 35 A 600023
QuickClip4 Set MU | Standard4 | 1 x male-female-female | 1 x female-male-male | 35 A 600190
Pumps
Modules
Accessories
QuickClip
Solar Charge
QuickCab Controller
to load
Find general PV connector
information on page 323
to battery
Tool-free PV Connectors
The spring coupling is designed for field
wiring without any special tools. Just
PV Connector Female
insert the cable, lock spring, tighten cable
Electronics
gland finished!
PV Connector Set
No special tools necessary.
Can be released with a screw-driver. PV Connector Male
Information on
PV Connectors, page 323
Generators
PN-Master Connectors
Safe and quick protection of cables. Suitable for wet
zones and subterranean applications due to its special
sealing. The lamellar construction ensures easy handling
Electronics
and makes it possible to connect two cables even with
different diameters between 6 13 mm without difficul-
ties. The Master Connector IP 68 can replace expensive
and complex cast parts and is therefore an economic
and quick alternative. According to DIN VDE 0606-1.
Batteries
Standard4 Connectors
are compatible with commercial 4 mm
PV-connector. They are designed for a strain
relief, waterproof and UV-resistant connection.
Crimp tool for processing is essential.
Loads
Information on PV Standard4 PV Standard4
PV Connectors, page 323 Connector Male EP Connector Female EP
Pumps
PV Standard4 Connector 2,5 mm Female EP 9g 390921
Cross section 2,5 mm | cable diameter 4,6 6,2 mm | 30 A
PV Standard4 Connector 2,5 mm Male EP 9g 390918
Cross section 2,5 mm | cable diameter 4,6 6,2 mm | 22 A
Accessories
301
Tools Accessories Pumps Loads Batteries Electronics Generators Kits
Kits
Tools Tools
Generators
Tools
Electronics
MORE
CIMCO
TOOLS ON
Hexagon Socket Keys Set (Case), 9 units REQUEST
9 units in a case
SW 1,5 mm, 2 mm, 2,5 mm, 3 mm,
4 mm, 6 mm, 8 mm, 10 mm
Hardened S2 special steel, polished 0DGHLQ
*HUPDQ\
8 units in a case: SW 2 mm, 2,5 mm, 3 mm, 4 mm, 5 mm, 6 mm, 8 mm, 10 mm
Accessories
MORE
CIMCO
Generators
TOOLS ON
REQUEST
Hexagon Socket Spanners Set 52-Part
Chrome vanadium steel, high-gloss polished
Socket spanner system 1/4", 1/2"
Screwing bit system 1/4" hexagon drive
Electronics
Hardened S2 special steel, polished
Batteries
Crimping Pliers [L] = 215 mm 485 g 390532
Loads
Pumps
Marking Plier Marking Plier Pocket Measure Tape Glas Fibre Measure Tape
Marking Pliers
Marking Pliers [L] = 230 mm 248 g 390533
Thorn crimping 0,5 16 mm
Marking Pliers [L] = 230 mm 243 g 390534
Thorn crimping 10,0 35 mm
Measure Tapes
Tools
MORE
CIMCO
Generators
TOOLS ON
REQUEST
Plier Set 1000 Volt 4 Pieces
Heavy duty side cutter, 200 mm
Telephone plier with straight jaws, 200 mm
Combination plier, 185 mm
Electronics
0DGHLQ
*HUPDQ\
Electricians-Screwdriver-Assortment-7-Part
VDE-electricians screwdrivers for slotted screws
VDE-crosshead-screwdrivers
Batteries
VDE-voltage tester
0DGHLQ
*HUPDQ\
MORE
CIMCO
Generators
TOOLS ON
REQUEST
Crimping Pliers
(Hexagon Crimping 6-50 and 16-95)
With incorporated, turnable profile
discs, toggle joint.
Electronics
Article Dimensions [l x w x h] Weight Article No.
Crimping Pliers (Hexagon Crimping 6-50) [L] = 435 mm 1,27 kg 390529
Crimping Pliers (Hexagon Crimping 16-95) [L] = 550 mm 2,05 kg 390530
Batteries
0DGHLQ
*HUPDQ\
Loads
Article Dimensions [l x w x h] Weight Article No.
Electrical Tool Case Electrical Engineer 1 455 x 205 x 305 mm 8,43 kg 390536
Pumps
Wire Stripping Plier 1000 V
For conductors up to 5 mm diameter, resp.
Accessories
0,75 mm up to 6 mm.
0DGHLQ
*HUPDQ\
Tools
0DGHLQ
*HUPDQ\
Loads
Generators
Light metal spirit level
Anodized, with 1 horizontal and 1 vertical level.
Made in
Electronics
Europe
Batteries
and PV Standard4 Connector 4 6 Female MU
Article Weight Article No.
Multicontact PV-MS 48 g 390412
Spanner Set
Loads
Pumps
Crimping Pliers for Standard4 contact
For processing contacts for Standard4.
0DGHLQ 0DGHLQ
*HUPDQ\ *HUPDQ\
4 x 4 rungs | [L] step ladder = 1,29 2,02 m, [L] ladder = 2,48 4,16 m
Aluminium extension ladder 4 x 5 16,0 kg 390722
4 x 5 rungs | [L] step ladder = 1,57 2,55 m, [L] ladder = 3,05 5,28 m
Accessories
0DGHLQ
Tools
0DGHLQ *HUPDQ\
*HUPDQ\
Generators
Electronics
0DGHLQ 0DGHLQ
*HUPDQ\ *HUPDQ\
Batteries
Hinges with additional side rail clamps crates are stackable
Polyester safety expansion belts Sealed cap design all round
Best wood protection due to boiled linseed Optimum form stability
oil coating 2 plastic coated spring hinged handles
Hinged covers can be locked with
Loads
commercially available padlocks
Cap with safety belts
Full rivets with all rivet joints
Pumps
Article Dimensions [l x w x h] Dimensions [l x w x h] Weight Article No.
inside outside
Wide-Rung Stepladder
5 rungs | [L] = 1,54m 9,5 kg 390719
Accessories
Aluminium Boxes
Size M | Volume 49 l 52 x 32 x 25 mm 57 x 37 x 27 mm 3,2 kg 390725
Size L |Volume 94 l 73 x 37 x 31 mm 77 x 42 x 33 mm 4,7 kg 390726
Size XL | Volume 146 l 84 x 43 x 36 mm 89 x 48 x 38 mm 5,8 kg 390727
3 in 1 All sizes in one 390728
Tools
Generators
Tips for Sizing
and Installation p. 312
Irradiation Maps p. 312
Electronics
Checklist for Solar Systems p. 315
Orientation of the Solar Panel p. 316
Easy Sizing p. 318
Conversion Table AWG p. 319
Cable Sizing p. 320
Ingress Protection (IP) p. 321
SI-Units p. 322
PV Connector Information p. 323
Pump Selection Diagram p. 324
Batteries
Charge Controller Information p. 329
Inverter Information p. 331
Battery Information p. 332
Lighting Information p. 337
Loads
Phaesun Services p. 339
Marketing Services p. 340
Return Shipments p. 341
Pumps
Off-Grid Experts Workshop 2015 p. 342
Off-Grid Experts Awards 2015 p. 343
Close partnerships
with manufacturers p. 344
Accessories
Glossary p. 354
Tools
Index p. 363
Service
311
Kits
Service Irradiation Maps
and Installation
Electronics
Irradiation Maps
Generators
Global Horizontal Irradiation Africa
Electronics
Batteries
Loads
Pumps
Accessories
Tools
Service
Checklist for Solar Systems
Generators
Costumer data
Company name
On our website
Electronics
Contact person
Company address you can find
Country checklists for
Phone different solar
Email systems.
DC Voltage
DC Voltage [VDC]
Batteries
(reduces battery requrirements)
DC load profile
Duration of operation
Quantity Type of load (DC) Power consumption [W] daytime nighttime
Loads
AC load profile
Pumps
Phase Duration of operation
Quantity Type of load (AC) 1 3 Power consumption [W] daytime nighttime Accessories
Days of autonomy
Required days
A preliminary survey of the location and the proper arrangement of the PV array are important
to maximize energy production of the Off-Grid PV system. The PV array needs to be installed
with a proper tilt angle, azimuth angle and with the minimum of shading.
Electronics
Tilt angle
PV arrays are most efficient, when they are
perpendicular to the suns rays. The default The following table shows the perfect tilt
value is a tilt angle equal to the stations angle in different locations:
latitude. This normally maximizes annual
energy production. The closer the system is Location Tilt Angle of Solar Panel
installed to the equator the smaller should be Memmingen 47
the tilt angle. (Germany)
However, the farer the system is located Istanbul (Turkey) 37
from the equator the more the suns path Agadir (Morocco) 30
Dakar (Senegal) 15
and the solar altitude vary throughout the
Quito (Ecuador) 0
year. In Europe for example the solar altitude
Lusaka (Zambia) 15
during summer reaches 60 65 whereas in
Cape Town 33
winter solar angles are as low as 13 18. (South Africa)
That means that the prefect tilt angle varies
Batteries
Ushuaia (Argen- 54
throughout the year.To optimize capture of tina)
solar panels a tilt angle of 28 30 in Europe
is recommended, plus 15 in winter, or minus
15 in summer.
Loads
Tilt angle:
The closer the system is installed to the equator the smaller should be the tilt angle.
Pumps
Accessories
45 30 15 0
Tools
Service
Generators
Geographical orientation Azimuth angle
To maximize the collection of the daily and seasonal solar energy possible, PV modules should
be oriented geographically. A solar panel facing the equator promises the highest energy yield.
In the northern hemisphere the optimum orientation for a PV module is true south (Azimuth
Electronics
180), in the southern hemisphere it is true north. However, PV modules can face up to 45 east
or west of true south (or north) without significantly decreasing their performance.
Batteries
W 90 90 E
75 75
60 60
45 45
30 15 15 30
0
S
Loads
Shading of photovoltaic cells
The electrical output of photovoltaic cells is very sensitive to shading.
Even when a small portion of the panel is shaded and the rest remains in
Pumps
sunlight the electrical output decreases drastically. Shading from trees,
poles, aerials, chimneys, existing or future buildings in the neighbourhood
all have a major impact on photovoltaic energy production.
The decreasing energy production due to shading has its electronic
Accessories
off-grid affairs.
The Lite edition offers a user-friendly interface
which makes it easy to size PV arrays and bat-
tery capacities.
Loads
Generators
AWG is a standardized wire gauge system for the diameters of round, solid, nonferrous,
electrically conducting wire. The cross-sectional area of each gauge is an important factor for
determining its current-carrying capacity.
Electronics
AWG Number Diameter in mm Cross section in mm2
1 7,350 42,400
2 6,540 33,600
3 5,830 26,700
4 5,190 21,200
5 4,620 16,800
6 4,110 13,300
7 3,670 10,600
8 3,260 8,350
9 2,910 6,620
10 2,590 5,270
11 2,300 4,150
12 2,050 3,310
Batteries
13 1,830 2,630
14 1,630 2,080
15 1,450 1,650
16 1,290 1,3100
17 1,150 1,0400
18 1,024 0,8230
Loads
19 0,912 0,6530
20 0,812 0,5190
21 0,723 0,4120
22 0,644 0,3250
23 0,573 0,2590
Pumps
24 0,511 0,2050
25 0,455 0,1630
26 0,405 0,1280
27 0,361 0,1010
Accessories
28 0,321 0,0804
29 0,286 0,0646
30 0,255 0,0503
Tools
Service
Cable Sizing
Generators
Electronics
C ro
ss -
sec
tio
n[
mm
]
Batteries
Current [A ]
Loads
Distance [m]
The wire cross section is calculated on the Example: voltage drop is exact 0,5 V if
Pumps
basis of a 0,5 V voltage drop. It is possible to distance is 5 meter, current is 7 A and a cross
use a thinner cable if for example open circuit section of 2,5 mm
voltage is high and MPP Trackers are used. Example: With a distance of 5 metres, 7 A of
power and a cable of 2,5 mm, the voltage
Accessories
Generators
EN 60529 outlines an international This classification system utilizes the letters
classification system for the sealing IP (Ingress Protection) followed by two or
effectiveness of enclosures of electrical three digits. (A third digit is sometimes used.
equipment against the intrusion into the An x is used for one of the digits if there is
Electronics
equipment of foreign bodies and moisture. only one class of protection.)
Batteries
3 Protection from entry by tools, wires, etc., with a diameter of thickness greater than 2,5 mm
4 Protection from entry by solid objects with a diameter or thickness greater than 1,0 mm
5 Protection from the amount of dust that would interfere with the operation of the equipment
6 Dust tight
Loads
Degrees of Protection Second Digit
The second digit indicates the degree of protection of the equipment inside the enclosure against
the harmful entry of various forms of moisture (e.g. dripping, spraying, submersion, etc.).
Pumps
Degrees of Explanation
Protection
Second Digit
0 No special protection
Accessories
SI-Units
Generators
silver 0,016 62
copper 0,018 56
gold 0,022 44
aluminium 0,028 36
Accessories
PV Connector Information
Generators
The terms male and female refer to the electrical contact inside the plug case, not to its
visible appearance.
Electronics
Male Female
We have introduced the terms PV Standard3 and PV Standard4 to match the plug systems.
These plug systems can be both connected with QuickCab3 and QuickCab4 cable extensions
Batteries
and QuickClip3 or QuickClip4 adapters and can be combined with all commercially available
3 mm and 4 mm PV plug systems. These plug systems usually require crimping pliers to
work with.
Loads
available which have 2 essentially different Waterproofness of the plug case is
characteristics: not guaranteed products of different
PV Standard4 can be directly and tool-free manufacturers are used
connected to a cable with the help of a The durability of the plug system may be
Pumps
spring clip and can be combined with all reduced If electrical contacts of different
4 mm plug systems and adapters manufacturers are incompatible with
PV Incomp4 can also be cabled without materials and contact erosion is involved.
the use of tools, however they are not
Accessories
15
20
30
40
50
60
70
80
90
100
125
150
175
200
250
300
Batteries
Range Diagram
Generators
Phaesun Pumping Small Phaesun Pumping Medium
WaterWater
tank tank <100<100
m3/day
m3/day WaterWater
tank tank <300<300 m3/day
m3/day
Electronics
<100<100
m TDHm TDH <200<200
m TDHm TDH
Submersible
Submersible Submersible
Submersible
pump/motor 1 x 30300
pump/motor 1 x 30300
VDC VDC pump/motor 3 x 230
pump/motor 3 xVAC
230 VAC
Batteries
Phaesun Pumping Large
Loads
Pumps
<300 m TDH
Accessories
Submersible
pump/motor 3 x 400 VAC
Tools
Service
Component Information
Electronics
A solar module or photovoltaic module converts the sunlight directly into electrical energy. The
module consists of solar cells which in turn are manufactured from mineral semiconductor mate-
rial, mainly silicon.
Monocrystalline cells
The manufacture of monocrystalline silicon cells requires
high-purity semiconductor material. Single-crystal rods are
drawn from molten silicon material and sawn into thin slices
afterwards. This manufacturing method ensures a relatively high
Batteries
degree of efficiency.
Polycrystalline cells
Polycrystalline cells, also called multicrystalline cells are
Loads
Generators
Compare the efficiency of the different cell types:
Electronics
Monocrystalline silicon approx. 24 14 to 17
Polycrystalline silicon approx. 18 13 to 15
Amorphous silicon approx. 13 5 to 7
200 40
19 %
150 30
14,5 %
Batteries
13 %
100 20
50 7% 10
0 W/m2 0 W/kg
Loads
Amorphus Polycrystalline Monocrystalline Back Contact modules
modules modules modules (Phaesun Sun Peak SPR)
Pumps
Accessories
Tools
Service
called back contact cell. They have both and CIGS stands for Copper Indium Gallium
positive and negative metallic contacts on the Selenide. The CIS/CIGS technology is normally
rear surface. That allows the surface facing the often used for flexible solar modules. The
sun to be uniformly black, without the metal CIS/CIGS absorber is deposited on a glass
electrodes present on most solar cells. The or plastic backing, along with electrodes on
back contact cell structure enables the module the front and back to collect current. The
to gain more electricity per unit area and leads semiconductor layer uses the broadest light of
to a more favourable appearance. all solar technologies. CIS/CIGS cells achieve
high conversion efficiencies at low production
costs, thanks to the fact that they have the
highest spectral response of all photovoltaic
technologies. They are suited for application
on flexible substrates and can be fabricated on
thin polymer foils without any compromise of
conversion efficiency
Batteries
Individual solar cells are interconnected to nominal capacities and voltages. The solar
modules with higher capacity. They are module specifications refer to the standard test
Loads
connected in series and in parallel in order conditions of 1000 W/m sun irradiation with
to be able to provide voltages or capacities 25 cell temperature.
appropriate for the different fields of Most Off-Grid solar modules are made out of
application. A series cell connection results 36, 72 or 142 cells to get a favourable voltage
in a higher voltage, a parallel connection for the battery of 12 VDC, 24 VCD or 48 VDC.
Pumps
involves a higher current. Solar modules are Standard modules for grid-connected systems
offered for different applications with different have 60 cells.
Accessories
Tools
Service
Generators
A solar module converts sunlight into direct directly charged. Moreover, a deep discharge
current. So the current from the solar module of the battery may considerably impair its
could be directly fed into the battery which durability when the loads are used excessively.
also stores the electricity as direct current The charge controller protects the battery
Electronics
which in turn could be used to serve DC from deep discharge, overload and short
consumers. circuits. It extends the durability of the
The solar modules voltage, however, is higher batteries considerably and should be on
than the voltage of a fully charged battery principle applied with self-sustaining solar
and can therefore damage a battery when it is systems.
Batteries
disables further current flow into batteries constant voltage battery charging by
when they are full. switching the solar system controllers power
devices.
Shunt controllers When a battery voltage reaches the regulation
A shunt controller continuously reduces the set point, the PMW algorithm reduces the
Loads
module power when the end of charge voltage charging current to avoid heating and gassing
is reached. But since the module continues of the battery. The result is a higher charging
producing power, the unneeded part of the efficiency, rapid recharging, and a healthy
modules power is used as a short-circuit battery at full capacity.
current without any problems. This method
Pumps
is ideal for the battery as charging is safe
and swift.
MPPT controllers
Accessories
Inverter Information
Generators
Electrical consumers use either DC (direct current), or AC (alternating current). Conventional
domestic appliances in Europe are based on 230 VAC and in America mainly on 110 VAC, since
this is the power that comes right from the socket.
Solar systems, however, produce 5 VDC, 12 VDC or 24 VDC direct current. Appropriately, many
Electronics
electrical devices are available in a correspondingly energy saving design. Phaesun has a wide
range of products for interior and exterior lighting, fans, TV sets and freezers/fridges on a
12 VDC or 24 VDC basis available.
If you wish to connect conventional domestic appliances based on 230 VAC or 110 VAC in
addition, you need an inverter to do so. An inverter enables you to operate any device from the
electrical toothbrush through to your sound system or vacuum cleaner.
Phaesun offers you exclusively high-quality pure to operate. The batteries are mostly a limiting
sinewave inverters to guarantee a reliable power factor here. The higher the battery capacity,
supply as easy as directly from the socket. the longer the potential operation time of the
The required inverter size depends on the electrical consumers. Energy saving loads such
capacity of the loads that must be served. If as LED lamps and TV sets are far less stressful
Batteries
you want to operate mainly TV or video sets for the battery than just a short hair drying with
and charging devices for mobile phones or a hair blower.
laptops, a 300 W inverter is sufficient. Larger The rule of the thumb is: Smaller inverters
inverters are required if devices with higher with up to 300 W should be connected with a
capacities, such as hairdryers, vacuum cleaners, battery of at least 100 Ah, larger inverters with
Loads
or microwaves are used. You should always take 1000/1500 W should go with a battery capacity
the size of the batteries into account when you of at least double this value.
are planning which electrical devices you wish
Pumps
Accessories
Tools
Battery Information
Generators
Electrical batteries consist of one or more electrochemical cells that convert stored chemical
energy into electrical energy. Rechargeable batteries or secondary cells can be recharged by
applying electric current, which reverses the chemical reactions that occur during its use.
Phaesun offer different types of rechargeable batteries as essential parts for Off-Grid power
Electronics
fibers are woven into a mat to increase current rating and long cycle life.
surface area enough to hold sufficient
electrolyte on the cells for their lifetime. The Lithium Cobalt Oxide (LiCoO2)
fibers that compose the fine glass mat do Li-cobalt is characterized by a high specific
not absorb nor are affected by the acidic energy but moderate safety, life span and
Tools
Generators
Lithium Manganese Oxide (LiMn2O4) Lithium Nickel Manganese Cobalt Oxide
Lithium manganese oxide improves ion flow (LiNiMnCoO2)
on the electrodes. It is characterized by a The NMC uses nickel, manganese and
good current handling and solid thermal cobalt as cathode material. Nickel is known
Electronics
stability with a low internal resistance. for its high specific energy but low stability,
and manganese forms a spinel structure
for low internal resistance but offers limited
specific energy. NMC offers good overall
performance with high specific energy, low
internal resistance and a moderate price.
Batteries
any eIectrolyte that spills onto the skin or
Keep children away from acid clothing. Rinse contaminated area clean
and batteries with water.
If acid is swallowed, get prompt medication
Risk of explosion: attention!
Loads
Charging batteries generates highly
explosive detonation mixture, Warning:
therefore: Do not expose unprotected batteries to direct
daylight. Discharged batteries can freeze;
Fire, sparks, open light and therefore, they need to be stored in a frost
Pumps
smoking protected environment.
are prohibited:
Avoid sparking when handling
cables and electrical devices!
Accessories
Lead accumulators are not a part of domestic waste and must be disposed of.
Would you like to dispose of your lead accumulators with us? We accept your batteries free of
Electronics
charge, however you have to bear the costs of delivery. Please return your used battery that you
purchased from Phaesun to our German company address.
Hg Cd Pb
With this information we perform our duty according to the battery law and refer to the
following obligations:
1. Batteries and accumulators are accepted free of charge after use at the sales point.
Loads
The symbols mean mercury (Hg) if more than 0,0005 mass percent mercury, cadmium (Cd) if
more than 0,002 mass percent cadmium and lead (Pb), if more than 0,004 mass percent lead
Pumps
are included.
turn of used
Please note: Re
possible with
batteries is only
Tools
ae su n RM A- Nu mber.
Ph
Service
Generators
Battery Wiring: 12 VDC Batteries
Electronics
24V/100Ah
12V/200Ah
12V
400Ah
Batteries
Battery Wiring: 2 VDC Batteries
12V/200Ah
Loads
2V/200Ah 2V/200Ah 2V/200Ah 2V/200Ah 2V/200Ah 2V/200Ah
For a series connection to 24V connect a total of 12 pieces 2V/200Ah batteries. For a series con- Pumps
nection to 48V connect a total of 24 pieces 2V/200Ah batteries
Accessories
12V
Tools
Battery Terminals
A S
Electronics
B
following graphics and
D can be connected with the
associated connectors.
Please refer to the respective
Batteries
Connectors
A M, S M, S, D B
Pumps
Accessories
Tools
Service
Lighting Information
Generators
Incandescent lamp Compare the light output and efficiency of
The incandescent light bulb is the traditional incandescent lamps, CFL and different kinds of
electric lighting mode. It produces light by LED lamps:
Electronics
heating a filament wire to a high temperature Power Output Efficiency
until it glows. The hot filament is protected (W) (Im) (lm/W)
from oxidation in the air with a glass enclosure Incandescent 60 850 14,2
that is filled with inert gas. lamp
CFL (e.g.Steca 5 250 50
Compact fluorescent lamp (CFL) Solsum ESL 5)
A CFL is a gas-discharge lamp that uses LED Lamp (e.g. 4,2 300 72
electricity to excite mercury vapor. The excited Lux Us WW
mercury atoms produce short-wave ultraviolet 300_12)
light producing visible light. A fluorescent LED Tube (e.g. 11 1100 100
Airtight Single
lamp converts electrical power into useful light
1100_24)
more efficiently than an incandescent lamp.
CFLs have two main components: a gas-filled
tube (also called bulb or burner) and magnetic The colour temperature of the
or electronic ballast. electromagnetic radiation is defined as its
Batteries
surface temperature in Kelvin. For example,
Light-emitting diode (LED) a warmer (i.e., lower color temperature)
An LED is a semiconductor light source. light is often used in public areas to promote
When the LED is switched on, electrons are relaxation, while a cooler (higher color
able to recombine with electron holes within temperature) light is used to enhance
Loads
the device, releasing energy in the form of concentration in offices.
photons as visible light. LEDs present many
Light Source Kelvin
advantages over incandescent light sources
and CFLs including lower energy consumption, warm white (ww) less than 3300 K
longer lifetime, improved robustness, smaller neutral white (nw) 3300 5000 K
Pumps
size, and faster switching. cold white (cw) more than 5000 K
Accessories
Lamp Sockets
To fix the lamps there are different sockets. conveniently changed out at the end of life.
Find the right lamp or lighting unit for your Some lamps have wire leads suitable for
Tools
Generators
Phaesun Services
Electronics
Supplier
Management PQM
& Procurement
Sales
Product
Management Logistics
Engineering Export
Batteries
Marketing Installation
& Training
Loads
Recycling Maintenance
& Monitoring
Pumps
Insurance Claim Management
Accessories
Phaesun specialises as a wholesaler in the field of Off-Grid PV and Wind. In this segment,
we offer our clients not only the most extensive assortment of selected quality components
made by international manufacturers, but also a wide range of services to support our custo-
mers with Off-Grid expertise und know-how exactly where this is necessary with a complex
subject such as Off-Grid.
Tools
Service
Marketing Services
Generators
Generators
Announcement of customer complaints with the respective trader
End supplier
Electronics
Announcement of the complaint with the contact of the sales department
Phaesun at Phaesun including invoice number and detailed description of fault as
customer well as system sizing if possible
Batteries
Clarification of the complaint with the supplier
Phaesun Shipment of the return goods to the respective distributor
Loads
Supplier and intermediaries
Pumps
so the complaint can be closed (feedback to the return service desired)
customer
Accessories
costs Phaesun
End customer
customer
costs
costs
Tools
yeah!
Service Off-Grid Experts Workshop 2015
d,
PV, win ro Solar
s
hyd system le
Off-gr
id
for mo
us e
bi
Solar
street-
25. 26. S e p t e m b e r lightin
g Rural
electrif
i-
Solar cation
g
pumpin
s
What? system
Generators
In 2015, the Off-Grid Experts Awards are
organised to award extraordinary achievements
in the field of Off-Grid power supply for
the second time. It is the only contest that
Electronics
prizes particularly innovative developments,
experiences and impressions in the field
of independent energy supply. The award
ceremonies and the following IndepenDance
Night will be the stunning end of the Off-Grid
Experts Workshop 2015 on 26.09.2015 in
Memmingen.
Batteries
The best photo and the best filmlet will be
determined by a public online voting.
The online voting is open from
15.07. 31.08.2015
Vote
Loads
now!
Pumps
Open the website and give your vote to your
favourite picture and filmlet:
Accessories
www.off-grid-experts.com
Tools
Service
With only one order our customers can get an individual range of products from all well known
PV-Off-Grid component manufacturers.
Electronics
We put great emphasis on a close relationship to our suppliers. This ensures the selection of the
best-in-class products, reliable sourcing and fast reaction in the case of any inconveniences with
the products.
Roland Studer
Batteries
Managing Director
Studer Innotec SA
Loads
Wholesale
companies
PV component
Pumps
** Governmental organisations
Tools
Service
Generators
Electronics
Batteries
Loads
Pumps
Accessories
Tools
CHARGE BOX
Service
8OP
(XURSDVWUDhH
$
.UHX]
0HPPLQJHQ
([LW $ 0HPPLQJHQ2VW
([LW
0HPPLQJHQ1RUG
(XURSDVWUDh
([LW $
hH
$
H
UD
6W
$XJVEXUJ
U
FK
QH 0QFKHQ
6 F K XP
Q
%X
J DFK
KH U ULQ 0
[
LP H HU U
DX
UDhH
HU L QJ
6WU HQ
Dh $G
'RQDXVW
/LQGDX W UD
hH 6FK
OHLI
HU 6 ZH
QJ
J
EX U J
$XJV
U W UL
$OOJX
( EH
hH
$LUSRUW
7L U R O H U 5 L Q J
%DKQKRIVWUD
JUDEHQ
V
QLJ
.
Batteries
$
&HQWUDO
+LQ
.DLVHUJUDEHQ
GH
6WDWLRQ
QE
0HPPLQJHQ
XU
JU
LQ
J
/ X LW S R O G V W U D hH
%UKOZHJ
U6WUDhH
Loads
$OOJXH
0HPPLQJHQ6G
([LW
6WUDhH
Pumps
$
EDFKHU
By train
5 minutes to walk from
*UQHQ
.HPSWHQ
Memmingen Train Station to
Phaesun. Alternatively we can
Accessories
By car By airplane
See the sketch above and follow the Phaesun Please call us once you have arrived at Allgu
signs to Brhlweg. Airport in Memmingen. We will come for you
Tools
by car.
Service
Generators
Phaesun France SAS, Vendargues (FR)
145, rue de la Marbrerie | Bote aux lettres n4 | 34740 Vendargues
Electronics
*DQJHV 6RPPLUHV
6DLQW*O\GX)HVF &DVWULHV
1PHV
0DUVHLOOHV
9HQGDUJXHV $
'
RXWHGH-DFRX
'5
H
'
QQ
FLH
0RQWSHOOLHU '
GR
&OHUPRQWO~+UDXOW
XH
QJ
/D
&HQWUH
/D
$Y
GHV
%LJR
V
1 1PHV
ULH
9HQGDUJXHV '
E
DU
H0
HG
9HQGDUJXHV
5X
([LW6RUWLH
$
HV
P
1
GH
H 6DLQW$XQV
Batteries
QX
$ YH
'
H
QQ
FLH
GR
XH
QJ
/D
/D
Loads
0RQWSHOOLHU
7UDPZD\/LJQH/
'LUHFWLRQ-DFRX
$
6WRS$UUW
1RWUH'DPHGH6DEODVVRX
Pumps
0RQWSHOOLHU
%DUFHORQH
7RXORXVH $HURSRUW,QWHUQDWLRQDO
0RQWSHOOLHU0HGLWHUUDQH
By car
Accessories
General Terms
Generators
& Conditions
Electronics
no specific objections are raised by the Seller, Sellers employees shall only be binding unless and
The services, deliveries and offers of the Seller when they are confirmed in writing by the Seller.
are carried out exclusively on the basis of these In order to be legally effective, declarations of
Terms and Conditions of the Seller. These thus also acceptance and all orders require written confirma-
apply to all future business relations, even if they tion from the Seller (order confirmation) or written
are not explicitly agreed upon again. These Terms confirmation by email and/or fax are sufficient.
Loads
and Conditions are taken as accepted at the latest All order acceptances are given exclusively on the
when the product or service is received. basis of these General Terms and Conditions of
Any other document than the present General Sale and Delivery. Supplements, amendments and
Terms and Conditions of Sale and Delivery, such as verbal agreements shall require a written confirma-
catalogues, prospects, advertisements and other tion by the Seller to be legally binding.
Pumps
notes shall only be informative and indicative, and Revocation of an order already sent by the
shall not constitute a contractual obligation. Any Purchaser and confirmed by the Seller shall be
offers, order acknowledgement, order acceptance inadmissible. Changes in the terms of the order
of sale of any product of the Seller is conditional (quantity, reference or technical specifications)
Accessories
upon the terms contained in this document. Any shall only be admissible within 24 hours after the
conditional or different terms proposed by the order confirmation has been sent by the Seller.
Purchaser are objected to and will not be binding (2) The quantity, quality and description of any
upon the Seller unless accepted expressly in specifications for the Goods shall be those set out
writing by the Seller. These conditions shall govern in the Sellers quotation (if accepted in writing by
any individual contract of sale between the Seller the Purchaser through an order) or the Purchasers
Tools
and the Purchaser. Any typographical, clerical or order (if accepted in writing by the Seller through
other error omission in any sales literature, quota- the order confirmation).
tion, price list, order confirmation, invoice or other Any such specification, sales literature, quotation
document of information issued by the Seller shall etc. shall be strictly confidential and must not be
Service
Generators
made available to third parties. The Purchaser 3. Price of the Goods
shall be responsible to the Seller for ensuring the (1) Unless stated otherwise, all prices are given by
accuracy of the terms of any order submitted the Seller on an ex-works (Incoterms 2010) basis,
by the Purchaser, and for giving the Seller any and where the Seller agrees on demand of the
Electronics
necessary information relating to the Goods within Purchaser to deliver the Goods elsewhere as at the
a sufficient time to enable the Seller to perform Sellers premises, the Purchaser shall be liable to
the contract in accordance with its terms. If the pay the Sellers charges for transport, packaging
Goods are to be manufactured or any process is to and insurance.
applied to the Goods by the Seller in accordance (2) Unless stated otherwise, the Seller is bound by
with the specification submitted by the Purchaser, the prices named in its offers for a period of 30
the Purchaser shall indemnify the Seller against days from the date of the offer.
all loss, damages, costs and expenses awarded (3) The prices named in the Sellers order confir-
against or incurred by the Seller in connection with mation plus the statutory Value Added Tax at the
or paid or agreed to be paid by the Seller in settle- time of the delivery or service are binding. Further
ment of any claim for infringement of any patent, deliveries and services are calculated and to be
copyright, design, trade mark or other industrial paid for separately. The prices given in the order
or intellectual rights of any other person which confirmation do not, unless it has been agreed
results from the Sellers use of the Purchasers spe- otherwise, include postage and packaging.
cification. The Seller reserves the right to make any (4) If at least three (3) months have, for any reason,
Batteries
changes in the specification of the Goods which passed between the conclusion of the contract and
may be required to conform to applicable statutory the delivery of the product, the Seller may raise the
requirements, without being held responsible for purchase price by an amount which corresponds to:
such changes. the rise in the cost-of-living index and
(3) In addition, where the Goods are to be supplied a modification of a tariff agreement and
Loads
to the Sellers specification, the Seller reserves the higher production costs and
right to make any changes which do not materially a currency regulation and
affect the quality or performance of the Goods. an alteration of duties and
(4) The information contained in any selling docu- a significant increase in the costs of materials
ments prepared by the Seller is only indicative and and other costs of manufacture or any change in
Pumps
shall not be legally binding. delivery dates.
(5) Any analysis or study undertaken or delivered (5) The price is exclusive of any applicable Value
on request of the Purchaser has to be verified by Added Tax, which the Purchaser shall be additio-
him before use. The Seller accepts no responsibi- nally liable to pay to the Seller.
Accessories
(7) Revocation of an order already sent by the (2) Payment shall be effected by interbank payment
Purchaser and confirmed by the Seller will gene- transaction only; no cheque or bill of exchange will
rate punitive damages of 10 % of the amount of be considered as fulfilment of the payment obliga-
the order. tion. It may be agreed between the parties that the
Purchaser has to deliver a Letter of Credit issued by
Service
a bank acceptable to the Seller. In this individual otherwise in writing. The Seller is not responsible
case it is assumed that any Letter of Credit will be for delays of delivery due to Force Majeure or due
issued in accordance with the Uniform Customs and to events which make the delivery considerably
Practice for Documentary Credits, 2007 Revision, more difficult or impossible for the Seller, even if
Electronics
ICC Publication No. 600. If the Purchaser fails to binding time periods and delivery deadlines have
make payment on the due date then, without pre- been agreed. Those events permit the Seller to
judice to any other right or remedy available to the delay the delivery or service for the duration of the
Seller, the Seller shall at his discretion be entitled to: hindrance, or to withdraw from the contract in full
cancel the contract or suspend any further or in part in relation to that part that has not been
deliveries to the Purchaser; fulfilled. The Seller is always permitted to carry out
or charge the Purchaser interest on the amount partial services or deliveries.
unpaid from the due date, at the rate of 7 per cent (2) The start of the delivery period stated by the
per annum above European Central Bank reference Seller is subject to the clarification of all technical
rate, until payment in full is made. The Purchaser questions. Compliance with the delivery obligation
shall be entitled to prove that the delay of payment of the Seller shall further presuppose punctual and
caused no or little damage only. proper performance of the Purchasers obligations.
(3) All orders shall be accepted under the provision The right to the plea of non-performance of con-
that the Purchaser is in the position to pay the tract shall remain reserved.
complete amount of the purchase price. If this (3) Delivery of the Goods shall be made by the
Batteries
prerequisite is no longer fulfilled, which shall be Purchaser collecting the Goods at the Sellers pre-
assumed if unfavourable information about the mises at any time after the Seller has notified the
Purchasers economic situation exists or payments Purchaser that the Goods are ready for collection
are not made within the agreed payment period, or, if some other place for delivery is agreed by
then the Seller can demand immediate cash the Seller, by the Seller delivering the Goods to
Loads
payment before delivery of the commodities, re- that place. If the Purchaser falls into arrears of ac-
gardless of the agreed payment date. In the event ceptance of the Goods or culpably breaches other
of a considerable deterioration of the financial cooperation duties, the Seller shall be entitled
situation of the Purchaser becoming known after to demand reimbursement of the costs incurred
conclusion of the contract or in the event of arrears by the Seller to this extent, including all and any
Pumps
in payment, the Seller shall have the right to with- additional expenditure and other damages. The
draw from the contract and to demand immediate right of the Seller to further-reaching claims shall
settlement of all claims, both due for payment and remain reserved.
not yet due for payment. If the Seller makes use (4) Where delivery of the Goods is to be made by
Accessories
of the right to withdraw from the contract, the the Seller in bulk, the Seller reserves the right to
Purchaser shall reimburse the Seller for the loss deliver up to 3 % more or 3 % less than the quan-
of profits or expenditure incurred with a view to tity ordered without any adjustment in the price,
the order placed, in particular with a view to the and the quantity so delivered shall be deemed to
working hours taken up. Payments must be made be in the quantity ordered.
exclusively to the Seller. (5) If a fixed and binding time for delivery is
Tools
(4) Rights of offset shall not be allowed. provided for in the contract, and the Seller fails
to deliver (in accordance with Point (3) of this
5. Delivery Article) within such time or any extension thereof
(1) The deadlines and time periods indicated granted, the Purchaser shall be entitled, on
by the Seller are not binding, unless agreed condition that the arrears in delivery are based on
Service
Generators
a breach of contract by malice aforethought or immediately after receipt. Complaints of any kind
gross negligence of the Seller and on giving to the shall be ruled out if they are not made within
Seller within a reasonable time notice in writing, to 14 days after the receipt of the Goods.
claim a reduction of 0,1 % of the delivery value for (5) Complaints or claims in relation to hidden
Electronics
each completed week of arrears, albeit no more defects which are difficult to discover in the course
than 3 % of the delivery value, unless it can be of the customary examination shall be addressed
reasonably concluded from the circumstances of directly to the manufacturer.
the particular case that the Purchaser has suffered (6) Defects of part of the delivery shall not entitle
no loss. the Purchaser to make claims in relation to the
(6) Liability for any loss of profits or any other entire commodities within a delivery.
consequential losses, including liability for loss of
income which can otherwise customarily be achie- 7. Retention of Title
ved with the sold product(s), shall be ruled out. (1) Notwithstanding delivery and the passing of
(7) To the extent possible, the quantity ordered risk in the Goods, or any other provision of these
by the Purchaser shall be provided. Any difference conditions, the property in the Goods shall not
in quantity resulting from the delivery note or the pass to the Purchaser until the Seller has received
invoice shall be notified to the Seller in writing, full payment of the price of the Goods and all
albeit not later than five (5) working days after other Goods agreed to be sold by the Seller to the
receipt of the commodities. Purchaser for which payment is then due.
Batteries
(8) If the Purchaser fails to accept delivery on due (2) If the Purchaser acts in breach of the contract, in
date, he shall nevertheless make payment as if particular in the case of payment default, the Seller
the delivery of the Goods had been accepted. The shall have absolute authority to retake, sell or other-
Seller shall arrange for the storage of the Goods wise deal with or dispose of all or any part of the
at the risk and cost of the Purchaser. If required by Goods in which title remains vested in the Seller;
the Purchaser the Seller shall insure the Goods at (3) Until such time as the property in the Goods
Loads
the cost of the Purchaser. passes to the Purchaser (passage of ownership),
the Purchaser shall hold the Goods as the Sellers
6. Transfer of Risks fiduciary agent, and shall keep the Goods properly
(1) In the case of Goods to be delivered at the stored, protected and insured at his own costs.
Pumps
Sellers premises (ex works, Incoterms 2010) the (4) Until passage of ownership the Purchaser
risk shall pass to the Purchaser at that time when shall be entitled to resell or use the Goods in the
the Seller notifies the Purchaser that the Goods are ordinary course of its business, but shall account to
available for collection. the Seller for the proceeds of sale or otherwise of
(2) In the event of dispatch being impossible the Goods including insurance proceeds, and shall
Accessories
without culpability on the part of the Seller, the keep all such proceeds separate from any moneys
risk shall pass to the Purchaser upon notification of or properties of the Purchaser and third parties.
availability for dispatch. (5) If the Goods are processed or reshaped by the
(3) The risk of damage to or loss of the Goods shall Purchaser and if processing is done with Goods
pass to the Purchaser as soon as the Goods have that the Seller has no property in, the Seller shall
Tools
been handed over to the person carrying out the become co-owner of the new object in the ratio
transportation, or as soon as the Goods have left of the value of the object of purchase (final invoice
the Sellers warehouse. This shall also apply when amount excluding VAT). If the blending is done
the Seller is assuming the transport costs. in such a way that Purchasers object is to be
(4) The Purchaser shall check the incoming Goods regarded as the main object, it shall be deemed
Service
agreed that the Purchaser assigns co-title to the 9. Warranties and Exclusion Clauses
Seller pro rata. (1) The Purchaser shall examine the Goods as requi-
(6) If third parties take up steps to pledge to other- red by German Law ( 377, 378 of the German
wise dispose of the Goods, the Purchaser shall Commercial Code) and in doing so check every
Electronics
immediately notify the Seller in order to enable the delivery in any respect.
Seller to seek a court injunction in accordance with (2) The Seller warrants that all items delivered
771 of the German Code of Civil Procedure. If under this agreement are under manufacturers
the Purchaser fails to do so in due time he will be warranty.
held liable for any damages caused. (3) The Seller shall not be liable for the Goods
(7) The Seller shall on demand of the Purchaser being fit for a particular purpose unless otherwise
release any part of the collateral if the value of agreed upon, to which the Purchaser intends to
the collateral held in favour of the Seller exceeds put them.
the value of the claims being secured. It is to the (4) The above warranty is given by the Seller
Sellers decision to release those parts of the subject to the following conditions:the Seller shall
collateral suitable for him. not be liable for any defect in the Goods arising
from any design or specifications supplied by the
8. Liability Purchaser;the Seller shall not be liable under the
(1) General provisions: With the exceptions of above warranty if the total price for the Goods has
gross negligence of the Seller and with the excepti- not been paid by the Purchaser at the due date for
Batteries
on of personal injury, the Sellers liability is limited, payment; the above warranty does not extend to
for all claims of the Purchaser in aggregate, to parts, material or equipment manufactured by or
the value of goods & services received by the on behalf of the Purchaser unless such warranty is
Purchaser to the extent such have been paid by given by the manufacturer to the Seller.
the Purchaser at the date of the Purchasers claim. (5) This warranty does not cover defects in or da-
The Purchaser warrants the waiver of liability from mage to the products which are due to improper
Loads
his insurers or from third party which have entered installation or maintenance, misuse, neglect or any
into separate contractual agreements with him, cause other than ordinary commercial application.
against the Seller or the Sellers insurers beyond (6) Any claim by the Purchaser which is based on
the limits and exclusions mentioned above. any defect in the quality or condition of the Goods
Pumps
(2) Liability for errors in Purchasers documents: shall be notified to the Seller within two weeks
The Seller is not liable for any damages due to the from the date of delivery.
Purchasers or third party errors relating to the (7) The Purchaser is entitled to demand the delive-
contract execution, nor damages resulting from ry of any substitute Goods, or repair or a reduction
the use of technical documents, data or other
Accessories
and/or indirect such as: operating loss of profit, (8) Where any valid claim in respect of any Goods
commercial loss or any other consequential losses which is based on any defect in the quality or
(including consequential and/or indirect damages condition of the Goods is notified to the Seller
for installation costs, transportation costs, hand- in accordance with these Conditions, the Seller
ling fees, travel costs, etc.) shall be entitled at the Sellers sole discretion to
Service
Generators
either replace the Goods free of charge or repair 11. Choice of Law; Place of Jurisdiction
the Goods. (1) This agreement shall be governed by and
(9) The Seller is not the manufacturer of the pro- construed in accordance with German law where
ducts sold by him. The Seller therefore assumes no a contract has been entered into between the
Electronics
kinds of duties from such guarantees or warranties Purchaser and Phaesun GmbH. This agreement
granted by the manufacturer. Written guarantee shall be governed by and construed in accordance
assurances granted by the Seller shall remain with French law where a contract has been
unaffected. entered into between the Purchaser and Phaesun
(10) The Seller does not guarantee the perfor- GmbHs subsidiary Phaesun France SAS. Where
mance of any system. The Seller does not give any there is uncertainty on which law shall apply the
guarantee of performance. The Seller assumes no German Law shall take precedence.
kind of guarantee of output or efficiency of any (2) Each party agrees to submit to the jurisdiction
system or component delivered to the Purchaser. of the courts selected by the Seller.
(3) The Seller shall have the right to bring a claim
10. Miscellaneous Clauses before a court at the Purchasers principal place
(1) The Seller reserves the right to improve or of business or at his discretion before any other
modify any of the products without prior notice, court being competent according to any national
provided that such improvement or modification or international law.
shall not affect the form and function of the
Batteries
product. In case of any discrepancy between the different
(2) This agreement supersedes and invalidates all translations of the Terms and Conditions the
other commitment and warranties relating to the English version shall prevail.
subject matter hereof which may have been made
by the parties either orally or in writing prior the
Loads
date hereof, and which shall become null and void
from the date of the agreement is signed.
(3) This agreement shall not be assigned or
transferred by either party except with the written
consent of the other.
Pumps
(4) Each party shall be responsible for all its legal,
accountancy or other costs and expenses incurred
in the performance of its obligation hereunder.
(5) In the event of a conflict between the German,
Accessories
Glossary
Electronics
A
ARPU
Absorbed glass mat (AGM) Average Revenue per user.
VRLA batteries with thin glass mat felt that holds
the electrolyte in place like a sponge. Azimuth
Angle between south and the point directly below
Alternating current (AC) the location of the sun. Measured in degrees east
Electric current in which the direction of flow is or west of true south in northern latitudes.
reversed at frequent intervals 230 VAC/50 Hz.
B
Altitude
The angle between the horizon and the suns Balance of system (Bos)
position in the sky. All system components and costs other than the
Batteries
PV modules.
Amorphous silicon
A non-crystalline semiconductor material, often Battery
used in thin film photovoltaic modules. Two or more primary cells connected together,
usually in series, to provide a source of electric
Ampere current.
Loads
Ampere-hour (Ah) BC
Accessories
Generators
The self-discharge rate is a measure of how much to be protected with another more easily corroded
batteries discharge on their own. The Self-Dischar- metal to act as the anode of the electrochemical
ge rate is governed by the construction of the cell. Cathodic protection systems are used to pro-
battery and the metallurgy of the lead used inside. tect a wide range of metallic structures in various
environments. Common applications are; steel wa-
Electronics
Battery state of charge ter or fuel pipelines and storage tanks; steel pier
Percentage of full charge or 100 percent minus the piles; ships and boats; offshore oil platforms and
depth of discharge. onshore oil well casings and metal reinforcement
bars in concrete buildings and structures.
BoS
Balance of System. Cell
Battery cells are the most basic individual com-
BOSS ponent of a battery. They consist of a container
Business Opportunities with Solar Systems: Solar in which the electrolyte and the lead plates can
Systems that can be used for income generation in interact. Each lead-acid cell fluctuates in voltage
non electrified areas. from about 2.
Batteries
flow towards a failed module or from the battery
to the PV array during periods of darkness or low Charge rate
current production. The current applied to a cell or battery to restore is
available capacity.
BTS
Base Transceiver Station (the name for the antenna CIS/CIGS solar cell
Loads
and radio equipment necessary to provide mobile Copper, Indium and (gallium) selenium amorphous
service in an area). solar cells
Pumps
A diode connected across one or more solar cells Club of Renewable Electrification Agencies.
in a photovoltaic module such that the diode will
conduct if the cell(s) become reverse biased. Alter- Concentrator
natively, a diode connected anti-parallel across a A PV module that uses optical elements to increase
part of the solar cells of a PV module. It protects the amount of sunlight incident on a PV cell. Con-
Accessories
these solar cells from thermal destruction in case centrating arrays must track the sun and use only
of total or partial shading of individual solar cells the direct sunlight because the diffuse portion
while other cells are exposed to full light. cannot be focused onto the PV cells.
C Conversion efficiency
The ratio of the electric energy produced by a
Tools
A type of PV cell made from a single crystal or Electric current in which electrons flow in one
polycrystalline slice of silicon. direction only.
flowing through a conductor. Current is usually at which electrical current is taken from the
measured in amperes (A). Current flow over time is battery.
defined as ampere-hours (a.k.a. amp-hours or Ah),
a product of the average current and the amount Dual-axis tracking
of time it flowed. A system capable of rotating independently about
two axes and following the suns orientation and
Cycle life height in the sky (e.g., vertical and horizontal).
Number of discharge-charge cycles that a battery
can tolerate under specified conditions before it Duty cycle
fails to meet specified criteria as to performance The ratio of active time to total time. Used to de-
(e.g., capacity decreases to 80-percent of the scribe the operating regime of appliances or loads.
nominal capacity).
E
D
Efficiency
Batteries
deeper batteries are discharged on average, the controlled overcharge. The process will cause the
shorter their so-called cycle life. battery electrolyte to boil and gas, so it should be
only done under strict supervision and with the
proper precautions.
Service
F Interconnect
Generators
A conductor within a module or other means of
FCL connection which provides an electrical intercon-
Fluorescent Compact Lamp nection between the solar cells.
Electronics
Float charge is the voltage required to counter- Devices that convert DC electricity into AC electri-
act the selfdischarge of the battery at a certain city (single or multiphase), either for stand-alone
temperature. systems (not connected to the grid) or for utility-
interactive systems.
G
IP
Gassing current Ingress Protection.
Portion of charge current that goes into electro-
lytical production of hydrogen and oxygen from I-V curve
the electrolytic liquid in the battery. This current A graphical presentation of the current versus
increases with increasing voltage and temperature. the voltage from a photovoltaic device as the
load is increased from the short circuit (no load)
Gel-type battery condition to the open circuit (maximum voltage)
Lead-acid battery in which the electrolyte is com- condition. Typically measured at 1000 watts per
posed of a silica gel matrix. square meter of solar insolation at a specific cell
Batteries
temperature. The shape of the curve characterizes
Gigawatt (GW) cell performance.
One billion watts. One million kilowatts. One
thousand megawatts. J
Loads
Global irradiation is the sum of direct and diffuse The joule is the basic SI unit of energy. A joule is
components of radiation. equal to the kinetic energy of a kilogram mass
moving at the speed of one meter per second.
GSM
Pumps
Global system for mobile communications. Junction box
An electrical box designed to be a safe enclosure
H in which to make proper electrical connections. On
PV modules this is where PV strings are electrically
Hybrid system connected.
Accessories
KWp is a measure of the nominal power of a silicon cell, this is at about 0,45 V.
photovoltaic solar energy device under laboratory
illumination conditions (see STC). The power is Maximum power point tracker (MPPT)
measured while varying the resistive load on the Means of a power conditioning unit that automa-
module between open and closed circuit. The tically operates the PV generator at its MPP under
Electronics
L Multi-crystalline
See poly-crystalline.
Life cycle cost
An estimate of the cost of owning and operating N
Batteries
NiCd
LiFePO 4 Nickel Cadmium.
Lithium Iron Phosphate.
NiMH
Pumps
Generators
Photovoltaic (PV)
Off-Grid Pertaining to the direct conversion of photons of
An autonomous photovoltaic or hybrid system sunlight into electricity.
not connected to the grid. Most Off-Grid systems
require batteries or some other form of storage. Photovoltaic array
Electronics
An interconnected system of PV modules that
Ohm function as a single electricity-producing unit. The
The unit of resistance to the flow of an electric modules are assembled as a discrete structure,
current. with common support or mounting. In smaller
systems, an array can consist of a single module.
Open-circuit voltage (Voc)
The maximum possible voltage across a photovol- Photovoltaic module
taic cell or module; the voltage across the cell in The smallest environmentally protected, essentially
sunlight when no current is flowing. planar assembly of solar cells and ancillary parts,
such as interconnections, terminals, and protective
OpzS devices such as diodes intended to generate
Tubelar plate with liquid electrolyte. DC power under unconcentrated sunlight. The
structural (load carrying) member of a module can
OpzV either be the top layer (superstrate) or the back
Tubelar plate with gel. layer (substrate).
Batteries
Orientation Photovoltaic peak watt
Placement according to the compass directions Maximum rated output of a cell, module, or
north, south, east, west. system. Typical rating conditions are 0,645 watts
per square inch (1000 watts per square meter)
P of sunlight, 68 degrees F (20 degrees C) ambient
Loads
air temperature and 6,2 x 10-3 mi/s (1 m/s) wind
P.l. speed.
Partial loss
Photovoltaic system
Parallel connection A complete set of components for converting
Pumps
A way of joining two or more electricity-producing sunlight into electricity by the photovoltaic
devices such as PV cells or modules, or batteries by process, including the array and balance of system
connecting positive leads together and negative components.
leads together; such a configuration increases the
Accessories
Peak sun hours small crystals (crystallites) form. The atoms within
The equivalent number of hours per day when single crystallites are symmetrically arranged,
solar irradiance averages 1000 W/m2 (full sun). whereas crystallites are jumbled together. These
Service
numerous grain boundaries reduce the device including silicon, gallium arsenide, copper indium
Generators
efficiency. A material composed of variously orien- dislenide, and cadmium telluride, are uniquely.
ted, small individual crystals.
Series connection
Power A way of joining electrical equipment by con-
Power is the product of voltage and current and necting positive leads to negative leads; such a
Electronics
is measured in Watts. Power over time is usually configuration increases the voltage while current
defined in Watt-hours (Wh), the product of the remains the same.
average number of watts and time. Your energy
utility usually bills you per kiloWatt-hour (kWh), Series regulator
which is 1000 watt-hours. Type of battery charge regulator where the char-
ging current is controlled by a switch connected in
Power factor series with the PV module or array.
The ratio of the average power and the apparent
voltamperes. Short-circuit current (Isc)
Pulse-width-modulated wave inverter (PWM): The current flowing freely from a photovoltaic
PWM inverters are the most expensive, but pro- cell through an external circuit that has no load or
duce a high quality of output signal at minimum resistance; the maximum current possible.
current harmonics. The output voltage is very close
to sinusoidal. SHS
Solar Home System.
Batteries
PV
Abbreviation for photovoltaic. Shunt regulator
Type of a battery charge regulator where the char-
PVPS ging current is controlled by a switch connected in
SLM = Standard Litre per Minute. parallel with the PV generator. Overcharging of the
battery is prevented by shorting the PV generator.
Loads
Pwm
Pulse wide modulation. Silicon
Silicon is a chemical element with the symbol Si
R and atomic number 14. Very pure silicon is the
base for most PV cells.
Pumps
Resistance R
The property of a conductor which opposes the Sine wave inverter
flow of an electric current resulting in the genera- An inverter that produces utility-quality sine wave
tion of heat in the conducting material. The unit of power forms.
Accessories
resistance is ohms.
SLA
Rpm Sealed Lead Acid.
Revolutions per minute.
SM
S Solar module.
Tools
Generators
The inverter consists of a DC source, four switches, The ability of an inverter or generator to deliver
and the load. The switches are power semiconduc- high currents momentarily required when starting
tors that can carry a large current and withstand a motor.
a high voltage rating. The switches are turned on
and off at a correct sequence, at a certain frequen- System integrator
Electronics
cy. The square wave inverter is the simplest and A system integrator is a person or company
the least expensive to purchase, but it produces that specializes in bringing together component
the lowest quality of power. subsystems into a whole and ensuring that those
subsystems function together
Stand-alone
see Off-Grid. T
Batteries
State of charge (SOC) An allowance made in charge controller set points
The State of Charge describes how full a battery for changing battery temperatures.
is. The exact voltage to battery charge correlation
is dependent on the temperature of the battery. Thin film
Cold batteries will show a lower voltage when A layer of semiconductor material, such as copper
full than hot batteries. This is one of the reasons indium diselenide, cadmium telluride, gallium
Loads
why quality alternator regulators or high-powered arsenide, or amorphous silicon, a few microns or
charging systems use temperature probes on less in thickness, used to make photovoltaic cells.
batteries.
Tilt angle
Pumps
String Angle of inclination of collector as measured in
A string are several solar modules connected in a degrees from the horizontal. For maximum perfor-
row. By doing so the system voltage will be increa- mance solar collectors/modules should be set at a
sed (sum of the voltage of each module). perpendicular to the sun.
Accessories
Sulfation Tracking
A condition that afflicts unused and discharged Free standing solar modules can be mounted on
batteries; large crystals of lead sulfate grow on the a tracking platform that can tilt the surface along
plate, instead of the usual tiny crystals, making the one or two axis (with a motor) to follow the sun
battery extremely difficult to recharge. and increase the energy boost.
Tools
Surge Transformer
The momentary start-up condition of a motor An electromagnetic device used to convert AC
requiring a large amount of electrical current. electricity, either to increase or decrease the
voltage.
Service
U VRLA
Generators
Vdc
Volts DC.
Loads
Voc
Open-circuit voltage.
Volt (V)
Pumps
Generators
Index
Electronics
A F
Accessories & Spares p. 231 Flexible Solar Modules p. 77
AGM Batteries p. 170 Flooded Batteries p. 186
Framed Solar Modules p. 68
B
Back Up Kits p. 48 G
Batteries p. 169 Gel Batteries p. 176
Battery Accessories p. 263 General Terms & Conditions p. 348
Battery Chargers p. 131 Generators p. 67
Battery Information p. 332 Generator Accessories p. 239
BOSS Business Opportunities Glossary p. 354
with Solar Systems p. 49 Grid Inverters p. 128
Grundfos Pumps p. 224
Batteries
C
Cable Sizing p. 320 H
Caravan Kits p. 36 How to find Phaesun p. 346
Charge Controller Information p. 329 Hybrid Charge Controllers p. 108
Checklist for Solar Systems p. 315
Loads
Close partnerships I
with manufacturers p. 344 Ingress Protection (IP) p. 321
Compact Fluorescent Lamps p. 213 Installation Material p. 283
Component Information p. 326 Inverter Information p. 331
Conversion Table AWG p. 319 Irradiation Maps p. 312
D K Pumps
DC Fans p. 218 Kit Accessories p. 232
DC Televisions p. 220 Kits p. 21
Accessories
DC / DC Converters p. 133
L
E LED Lamps p. 204
Easy Sizing p. 318 LED Lighting Units p. 206
Electronics p. 85 Lighting Information p. 337
Tools
Refrigerators and Freezer Boxes p. 214 Studer Stand Alone Inverters p. 156
Off-Grid Experts Workshop 2015 p. 342
Off-Grid Experts Awards 2015 p. 343 T
Rural Electrification Kits p. 43 Tips for Sizing and Installation p. 312
Tools p. 301
Pumps
S
Service p. 311 W
Shurflo Pumps p. 227 Water Desalination p. 65
SI-Units p. 322 Water Treatment p. 63
Accessories
Generators
Electronics
Batteries
Loads
Pumps
Accessories
Tools
www.phaesun.com
Service
www.phaesun.com
Service
Generators
Electronics
Batteries
Loads
Pumps
Accessories
Tools
www.phaesun.com
Service
www.phaesun.com
Service
This catalogue has been developed for our resellers and industrial clients.
It shall remain our sole property and can be reclaimed in case of misuse.
All rights reserved, especially the right of duplication, reproduction and translation.
Any reproduction, processing, duplication, distribution or storage on electronic
systems, or by means of fotocopy, microfilm, or other methods, even in parts, is
prohibited without prior approval.
Pictures: Phaesun
Editorial Staff: Dirk Gutzeit, Tanja Leuschner, Graldine Quelle, Andreas Schfer
Layout: Julia Zugmaier
Druck: AZ Druck und Datentechnik GmbH, Kempten
by Phaesun GmbH
ALLGU BERLIN
Global horizontal Irradiation
Latin America
30 angle
20 angle
Equator
30 angle
Irradiation Group IG 3:
4 kWh/m
Irradiation Group IG 4:
3 kWh/m
The components of the Phaesun Kits depend on the solar irradiation of the specific
location. Find out your irradiation group and choose the adapted Phaesun Kit.
For Western Streetlight Kits please choose also the right angle.
Global horizontal Irradiation
Africa
customised
30 angle 55 angle
20 angle
Equator
Irradiation Group IG 3:
4 kWh/m
Irradiation Group IG 4:
3 kWh/m
The components of the Phaesun Kits depend on the solar irradiation of the specific
location. Find out your irradiation group and choose the adapted Phaesun Kit.
For Western Streetlight Kits please choose also the right angle.
Phaesun GmbH
Brhlweg 9
87700 Memmingen
Germany
www.phaesun.com