11-1
p (m + 1)(n 1)
UCL = F , p ,mn m p +1
mn m p + 1
2(50 + 1)(25 1)
= F0.001,2,1199
50(25) 50 2 + 1
= ( 2448 1199 ) (6.948) = 14.186
LCL = 0
Excel : workbook Chap10.xls : worksheet Ex10-1
Sample No. 1 2 3 4 5 6 7 8 9
xbar1 58 60 50 54 63 53 42 55 46
xbar2 32 33 27 31 38 30 20 31 25
diff1 3 5 -5 -1 8 -2 -13 0 -9
diff2 2 3 -3 1 8 0 -10 1 -5
matrix calc 0.0451 0.1268 0.1268 0.0817 0.5408 0.0676 0.9127 0.0282 0.4254
t2 = n * calc 1.1268 3.1690 3.1690 2.0423 13.5211 1.6901 22.8169 0.7042 10.6338
UCL = 14.1850 14.1850 14.1850 14.1850 14.1850 14.1850 14.1850 14.1850 14.1850
LCL = 0 0 0 0 0 0 0 0 0
OOC? In control In control In control In control In control In control Above UCL In control In control
60.00
50.00
40.00
T^2
30.00
20.00
10.00
0.00
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Sample Number
(a)
Phase II limits:
p (m + 1)(n 1)
UCL = F , p ,mn m p +1
mn m p + 1
6(30 + 1)(3 1)
= F0.005,6,55
30(3) 30 6 + 1
372
= (3.531)
55
= 23.882
LCL = 0
(b)
The Phase II UCL is almost 30% larger than the chi-square limit.
(c)
Quality characteristics, p = 6. Samples size, n = 3. = 0.005. Find "m" such that exact
Phase II limit is within 1% of chi-square limit, 1.01(18.548) = 18.733.
Excel : workbook Chap10.xls : worksheet Ex10-5
720 preliminary samples must be taken to ensure that the exact Phase II limit is within 1%
of the chi-square limit.
11-11
(a)
1 0.8 0.8
= 0.8 1 0.8
0.8 0.8 1
(b)
UCL = 2 , p = 0.05,3
2
= 7.815
(c)
T 2 = 11.154
( )
Yes. Since T 2 = 11.154 > ( UCL = 7.815 ) , an out-of-control signal is generated.
(e)