Sunteți pe pagina 1din 287

No Categories Products Page

1 Electrical Engineering & Electronics 1 ~ 54


2 Automation 55 ~ 65
3 Electromechanics 66 ~ 118
4 Power Electronics 119 ~ 139
5 Electricity Supply System 140 ~ 143
6 Electric Power Engineering 144 ~ 165
7 Renewable Energy 166 ~ 174
8 Electric Safety 144 ~ 165
9 Energy Saving 184 ~ 185
10 Element Automations 186 ~ 189
11 Electric Installation Work 190 ~ 192
12 Radio Engineering 193
13 Smart Grids 194
14 New Products 195 ~ 286
EQUIPMENT BRAND
ELECTRICAL ENGINEERING AND ELECTRONICS G A L S E N
No Name of Equipment Quantity
1 Electric Circuits and Fundamentals of Electronics 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Magnetic circuits (Experimental study and
Electric DC circuits (Measurement of calculation of the magnetic circuit with DC; ECOE1-N-R Please Contact Us
resistance, current, voltage and electric Experimental study of the magnetic P I C T U R E
power; Series connection of resistors; circuit with AC; Testing singlephase
Shunt connection of resistors; Combined transformers)
connection of resistors; Readout of Fundamentals of electronics (Study of
voltampere diode; Study of bipolar transistor; Study of
characteristics of nonlinear elements) single-phase rectifiers; Study of threephase
Electric circuits of single-phase bridge rectifier; Study of controlled
sinusoidal current (Series connection rectifiers and thyristor regulators;
of R, L and Study of bipolar transistor work in key mode;
C; Shunt connection of L and C) Study of two stage transistor amplifier; Study
Electric circuits of three-phase of DC voltage stabilizers; Study of RS trigger,
sinusoidal multivibrator and single-
current (Star load connection; shot trigger; Study of circuits with
Triangle load connection; Faults in operational amplifiers)
threephase circuits)

Modules / Components:
Voltage Generators Module with
Composition Field
Single-phase Power Supply Desktop Containter with 1-Level Frame
Two Multimeters Unit Accessories Kit
Wattmeter Basic Experiments Guide
"Electric & Electronic Components" Single-Channel Oscilloscope
Minimodules Set

Page 1
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 Theory of Electric Circuits and Fundamentals Of Electronics 1 Set Unit Prices Total Prices
Basic Experiments: delta. Circuits with nonsinusoidal
Type / Model ( Rupiah ) ( Rupiah )
Electric DC circuits (Parameters of electrical applied voltage. Transients in TECOE1M-S-K Please Contact Us
DC circuit. Ohm's law. Resistor circuits: linear circuits) P I C T U R E
Linear resistors, Heat-variable resistor with Long-distance line (Voltage
negative temperature factor, Heat-variable distribution along homogeneous
resistor with positive temperature factor, long-distance line. Input resistance
Varistor, Photoresistor, Series resistor connection, of long-distance transmission
Parallel resistor connection, Seriesparallel line as function of its electrical
resistor connection, Resistance voltage length and load resistance.
divider. Voltage (EMF) source Series Reflected waves)
connection of voltage (EMF) source. Electronic devices (Rectifier
Parallel connection of voltage (EMF) diodes: Diode characteristics:
source. Electrical power and energy. Single-phase half-wave
Electrical efficiency. Voltage, current and uncontrolled rectifier, Single-phase
power matching between voltage (EMF) bridgecircuit uncontrolled rectifier,
source and load. Charge and discharge of Three-phase bridge-circuit
capacitor. Switching-on and switching-off uncontrolled rectifier, Threephase
circuit with inductor) zero uncontrolled rectifier.
Electric AC circuits (Parameters of sinusoidal Stabilitron: Characteristics,
voltage and current. Circuits of sinusoidal Parametric voltage stabilizer,
current with capacitors. Circuits of sinusoidal Smoothing ripples of rectified
current with inductors. Circuits of voltage. Diodes with special
sinusoidal current with resistors, capacitors properties
and inductors. Transformers: Magnetic linkage (LED, Varicap). Bipolar transistors:
factor, Transformation factor, Testing
Resistance conversion by means of transformer.
Three-phase circuits of sinusoidal
current. Failure modes of three-phase cir- layers and study of rectifying action of bipolar transistors, Distribution of current in the
cuit when load connected star. Failure modes of three- transistor and the control effect of the base current of the transistor, Transistor
phase circuit when load connected characteristics, Setting the operating point of the
transistor, and study of effect of resistor in the collector circuit to the voltage gain of

Page 2
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Modules / Components:
Voltage Generators Module; Single-phase
Power Supply; Testing Board; Connector;
Long-distance Line Model; Module Of Two
Multimeters; Mini-modules Set Electric
And Electronic Elements; Mini-modules
Set Transformers; Computer Table
Laboratory Table With 2-section Container
and 1-level Frame; Accessories Kit; Basic
Experiments Guide ; Personal Computer

the amplifier stage with a common emitter, Amplifiers using bipolar transistors, Linear
voltage regulator, Linear current regulator. Unipolar (field) transistors: Testing layers
and study of rectifying action of unipolar transistors, Turn-on of transistor gate, Control effect of n-
type transistor gate, The output characteristics of transistor, Amplifiers. Thyristors: Characteristics
of diode thyristor, Characteristics of triode thyristor,. Phase control of thyristor. Logic elements
(AND, OR, NO, NAND, NOR). Operational amplifiers: Inverting amplifier, Non-inverting amplifier,
Summing amplifier, Differential amplifier, Dynamics of operational amplifier)

Page 3
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
3 Electrical Engineering and Fundamentals of Electronics 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
BASIC EXPERIMENTS :
Electrical and magnetic circuits EOE3M-N-R Please Contact Us
DC circuits (Parameters of electrical DC circuit. Volt-ampere characteristics of when load connected star. Failure modes of three-phase circuit when load connected delta)
nonlinear elements in DC circuit) Fundamentals of electronics (Single-phase rectifier Three-phase bridge-circuit controlled
Single-phase AC circuits (Series connection rectifier. Controlled rectifiers and thyristor regulator. Two-stage ransistor
of elements R, L and (sinusoidal current). Parallel capacitor-inductor connection) Magnetic circuits (DC magnetic circuits. AC magnetic circuits. Test of singlephase
Three-phase AC circuits (Star connection of three-phase electrical load. Delta connection of transformer).
three-phase electrical load. Failure modes of three-phase circuit
P I C T U R E
amplifier. DC voltage stabilizer. RStrigger, multivibrator Modules / Components:
and single-shot trigger. Circuits with operational Electromechanical Unit (DC
amplifiers) Machine, AC Motor And Angular
Electrical machines and drives DC generators with Displacement Transducer);
separate excitation (Characteristic of idling E =f (I ). 0 f Module Of Voltage Generators
Characteristics of short circuit I =f(I ). K f Characteristics With Testing Board; Frequency
U=f(I), If=f(I) and U=f(I ) f Converter; Single-phase Power
DC motors with shunt excitation and Supply; Active Load; Excitation
drive on its basis (Electromechanical (speed) Rheostat Of DC Machine;
characteristics n = f (I). Mechanical characteristics of n = Adjustable Autotransformer;
f (M). Speed control of DC motor by changing armature Rectifier; Speed Indicator; Module
voltage. Speed control of a DC Of Three Multimeters; Module Of
motor by field current changing. Determination of Two Multimeters; Wattmeter;
coordinates of electrical motor in motor, generator, and Voltammeter; Electrical And
braking modes) Electronic Components
Three-phase asynchronous motor with Mini-modules Set; Desktop
squirrel-cage rotor and drive on its basis Container With Two-level Frame;
(Electromechanical (speed) characteristic n=f(I). Desktop Container With Single-
Mechanical characteristic n=f(M). Speed control by level Frame; Accessories Kit;
match changing frequency and magnitude of stator Basic Experiments Guide; Single-
voltage. Determination of coordinates of electrical drive channel Oscilloscope
in motor, generator, and braking modes)

Page 4
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
4 Electrical Engineering and Fundamentals of Electronics 1 Set Unit Prices Total Prices
Basic Experiments: Circuits with operational amplifiers)
Type / Model ( Rupiah ) ( Rupiah )
Electrical and magnetic circuits Electrical machines and drives EOE6-S-R Please Contact Us
DC circuits (Parameters of electrical DC generator with independent excitation P I C T U R E
DC circuit. Volt-ampere characteristics (No-load characteristic E =f(I ) . Short cir- 0 F
of nonlinear elements in DC circuit) cuit characteristic I =f(I ).Characteristics SC F
Single-phase AC circuits (Series U = f (I), I = f (I) and U = f (I ) F F DC motor
connection of elements R, L and (Electromechanical (speed) characteristic n = f
(sinusoidal current). Parallel capacitor- (I). Mechanical characteristics n = f (M)
inductor connection) Three-phase squirrel-cage induction
Three-phase AC circuits (Star motor (Electromechanical (speed)
connection of three-phase electrical characteristic
load. Delta connection n = f (I). Mechanical characteristic
of three-phase electrical load. n = f (M)
Failure modes of three-phase circuit
with load connected star. Failure Modules / Components:
modes of three-phase circuit with load Electromechanical Unit (DC Machine, AC
connected Motor and Angle-to-digit Converter);
delta) Threephase
Magnetic circuits (DC magnetic Power Supply; Voltage Generators &
circuits. AC magnetic circuits. Test of Testing Board Module; Single-phase Power
singlephase transformer) Supply; Active Load; Adjustable
Fundamentals of electronics (Single- Autotransformer;
phase Rectifier; Tachometer; Stand For
rectifier. Three-phase bridge-circuit Tachometer; Three Multimeters Module;
controlled Wattmeter; Electrical And Electronic
rectifier. Controlled rectifiers and Components Mini-modules Set; Two-level
thyristor regulator. Two-stage Frame With Container; Accessories Kit;
transistor Basic Experiments Guide; Single-channel
amplifier. DC voltage stabilizer. Oscilloscope
RStrigger,
multivibrator and single-shot trigger.

Page 5
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
5 Electrical & Magnetic Circuits, Fundamentals Of Electronics 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Basic Experiments:
Electrical and magnetic circuits (Linear DC circuits. AC circuits. Three-phase circuits. EMCOE1-N-R Please Contact Us
Transients in linear electrical circuits. Quadripoles. Distributed-element circuits. Nonlinear P I C T U R E
electric and magnetic circuits )
Fundamentals of analog electronics
(Semiconductors. Electronic circuits and microcircuitry. Stabilizers and secondary
sources of supply)
Fundamentals of digital electronics
(Testing basic logic elements. Assembly and test of simple combinational nodes of digital
devices. Assembly and test of sequential nodes of digital devices)

Modules / Components:
Module of voltage generators with testing board; Single-phase power
supply; Model of long-distance line Model; Module of two multimeters;
Wattmeter; Fundamentals of digital electronics Mini-modules Set;
Analog electronics Electrical components Mini-modules Set; Analog
electronics Electronic components Mini-modules Set;
Electromagnetic components Minimodules Set; Desktop container with
1- level frame; Accessories Kit; Basic Experiments Guide; Two-channel
oscilloscope (not shown

Page 6
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
6 Digital Electronics Fundamentals 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Basic Experiments:
Testing basic logical elements OCE1-N-R Please Contact Us
Assembly and test of simple combinational P I C T U R E
nodes of digital devices (Combinational node using basic logic elements to implement
arbitrary logic function. Combinational nodes using basic logic elements for experimental
confirmation of logic algebra laws. Single-digit halfadder and adder. Code converter and
decoder. Multiplexer and demultiplexer)
Assembly and test of sequential nodes of digital devices (Triggers. Counters.
Registers)
Assembly and test of digital-to-analog converter (Digital-to-analog converter
with current output. Digital-to-analog con-SEN OCE1-N- verter with voltage output. Codes
comparison. Pulse-length modulator)
Assembly and test of analog-digital converter
(Analog comparator. Analog-digital converter of sweep conversion. Analogdigital converter of
tracing conversion. Analog-digital converter of successive approximation)
Assembly and test of multivibrators (Test of chip in multivibrators modes. Test of
timer in multivibrator modes)
Assembly and test of storages Assembly and test of parity control schemes Circuitry of
logic elements

Modules / Components:
Single-phase Power Supply
Module Of Testing Digital Devices
Mini-modules Sets Fundamentals Of
Digital Technology
Desktop Container With 1-level Frame
Accessories Kit
Basic Experiments Guide
Multimeter

Page 7
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
7 Analog Electronics Fundamentals 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Semiconductors (Characteristics of semiconductor diodes for direct and alternating currents. OAE1-N-R Please Contact Us
Main characteristics of stabilitron and study of parametric voltage regulator. Current-voltage P I C T U R E
characteristics of LED. Variable capacitance diode (varicap). Test of p-n junctions of bipolar
transistor and receiving its output characteristics with an oscilloscope. Static characteristics of
transistor for direct current. Choice of bipolar transistor operating point and familiarization with
AC voltage amplification mode of classes A, B, AB, and D. Static characteristics of a field-
effect transistor with p-n junction.Static characteristics of fieldeffect transistor, insulated gate
and induced channel.Main characteristics of thyristors.Basic characteristics and parameters of
photocouplers)
Electronic circuits and microcircuitry
(Comparative study of single amplifier stages using bipolar transistors.Study of the amplifier
stages using FET. Study of two-stage transistor amplifier. Study of the basic circuits of
operational amplifier. Removing the frequency characteristics of operational amplifier.
Summation, integration and differentiation schemes on operational amplifiers. RC-filter using
operational amplifier. Simple logarithmic converter using operational amplifier. Generator of
sinusoidal oscillations using operational amplifier. Schmitt trigger and relaxation oscillators
using operational amplifier. RS-trigger, multivibrator and single-shot trigger. Analog integrated
comparators and circuits with them.Selfoscillating and standby modes of analog timer using
integrated chip.Generator of special form voltage (function generator) using integrated chip
Stabilizers and secondary sources of supply
(Half-wave and bridge-circuit rectifiers. Three-phase bridge-circuit rectifier and smoothing
filters. Controlled rectifiers and thyrister regulator with phase control. Degenerative voltage and
current stabilizers. Main schemes of coupling linear integral voltage regulator. PWM DCDC
converter. Integral pulse converter - voltage stabilizer with pulse-frequency modulation)

Modules / Components:
Module Of Voltage Generators With Testing Board; Single-phase Power Supply; Wattmeter;
Analog Electronics Electrical Components Mini-modules Set; Analog Electronics -
Electronic Components Minimodules Set; Desktop Container With 1- level Frame;
Accessories Kit; Basic Experiments Guide; Two-channel Oscilloscope

Page 8
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
8 Digital & Microprocessor Technology Fundamentals 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
P I C T U R E
OCMOCMT1-N-KTN-K Please Contact Us

Testing basic logical elements Assembly and test of simple


combinational nodes of digital devices (Combinational node
using basic logic elements to implement arbitrary logic function.
Combinational nodes using basic logic elements for
experimental confirmation of logic algebra laws. Single-digit
halfadder and adder. Code converter and
decoder. Multiplexer and demultiplexer)
Assembly and test of sequential nodes of digital devices
(Triggers. Counters. Registers)
Study of basic features of programming environment
Coding of microcontroller timer (Generation of delay by
means of timer. Generation of signal of predetermined
frequency. Measuring external signal length by means of timer.
Study of counter with programmable division factor based on
timer. Using interruptions in microcontroller
coding. Coding analog-to-digital microcontroller. Study of digital-
to-analog converter on basis of microcontroller pulse-width
modulation signals)
Signal transfer along sequential transmission
channels (Data transmission using channel SPI. Data
transmission
using channel USART)
Using microcontroller in applications
(Measuring time intervals. Measuring temperature)
Modules / Components:
Single-phase Power Supply ;Module Of Testing Digital Devices;Fundamentals Of Digital Technology
Minimodules ;Set Microcontrollers Mini-modules Set Desktop Container With 1-level Frame Accessories Kit
Basic Experiments Guide Multimeter Notebook With Software

Page 9
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
9 Slip Ring Induction Motor Labware Set 1 Set Unit Prices Total Prices
Power consumption, VA, not 500 Type / Model ( Rupiah ) ( Rupiah )
Name Pcs ADFR1-N-R Please Contact Us
more than
1 Electromechanical set (DC 1
Electrical supply:
machine, AC motor and angle-
P I C T U R E
-three-phase AC
to-digit converter)
circuit with orking neutral and
2 Three-phase power supply 1
protective leads 380
3 Single-phase power supply 1
- voltage, V 38
4 Active load 1
- single-phase AC circuit
5 AC machine rotor rheostat 1
with
6 Line reactor 1
working neutral and 220
7 Adjustable autotransformer 1
protective leads 22
8 Rectifier 1
- voltage, V 50 0,5
9 Three-phase transformer group 2
- frequency, Hertz
10 Speed indicator 1
Class of protection against I
11 Wattmeter 1
electrical shock
12 Three multimeters module 1
Overall dimensions, mm, not
13 Two-level frame with container 1
more than 2x910
14 Single-level frame with container 1
- length 350
(length 910 mm)
- width 800 List of basic experiments:
15 Set of accessories 1
- height
16 User Manual Three-phase slip 1
Weight, Kg, not more than 110 1. Characteristics.
ring induction motor 1. Finding no-load characteristics I0=f(U), 0=f(U), cos0=f(U).
Number of persons who that
can simultaneously and 2 2. Finding short circuit characteristics ISC=f(U), SC=f(U), cosSC=f(U).
3. Finding mechanical characteristic n=f(M).
actively work on the set
4. Finding operational characteristics I=f(P2), P1=f(P2), s=f(P2), =f(P2),
cos=f(P2), M=f(P2).
2. Speed control.
2.1. Speed control by changing stator voltage.

Page 10
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
10 Induction Motor With Squirrel-Cage Rotor Labware Set 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA, 500 ADKR1-N-R Please Contact Us
Name Pcs
not more than P I C T U R E
1 Electromechanical set (DC 1
Electrical supply:
machine, AC motor and angle-
-three-phase AC
to-digit converter)
circuit with
2 Three-phase power supply 1 380
working neutral and
3 Frequency converter 1 38
protective leads
4 Single-phase power supply 1
- voltage, V
5 Active load 1
- single-phase AC 220
6 Adjustable autotransformer 1
circuit with 22
7 Rectifier 1
working neutral and 50 0,5
8 Three-phase transformer group 1
protective leads
9 Adjustable three-phase 1
- voltage, V
autotransformer
- frequency, Hertz
10 Speed indicator 1
Class of protection against I
11 Wattmeter 1
electrical shock
12 Three multimeters module 1
Overall dimensions, mm,
13 Voltmeter 1 2x910
not more than List of basic experiments:
14 Two-level frame with container 1 350
- length 2. Characteristics.
15 Single-level frame with container 1 800
- width 1. Finding no-load characteristics I0=f(U), 0=f(U), cos0=f(U) .
(length 910 mm) 2. Finding short circuit characteristics ISC=f(U), SC=f(U), cosSC=f(U) .
- height
16 Set of accessories 1 3. Finding mechanical characteristic n=f(M).
Weight, Kg, not more than 110
17 User Manual Three-phase 1 4. Finding operational characteristics I=f(P2), P1=f(P2), s=f(P2), =f(P2),
squirrel-cage induction motor cos=f(P2), M=f(P2).
2. Speed control.
2.1. Speed control by changing stator voltage.
2.2. Speed control by match changing frequency and magnitude of stator voltage.

Page 11
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
11 Electrical circuits and fundamental of electronics 1 Set Unit Prices Total Prices
Components list Type / Model ( Rupiah ) ( Rupiah )
Name Pcs BASIC EXPERIMENTS ECOE2-S-R Please Contact Us
1 Module of voltage generators 1
P I C T U R E
with testing board 1. DC electrical circuits.
2 Single-phase power supply 1 1. Measurements of resistance,
3 Module of testing digital 1 current, voltage and electrical
power in DC circuits.
devices
2. Series connection of resistors.
4 Module of 2 multimeters 1 3. Parallel connection of resistors.
5 Wattmeter 1 4. Series-parallel connection of
6 Mini-modules Set Electrical 1 resistors.
and electronic components 5. Volt-ampere characteristics of
7 Mini-modules Set 1 nonlinear DC elements.
Fundamentals of digital 2. Single-phase AC electrical circuits.
1. Series connection of elements R, L
electronics
and .
8 Laboratory table with 1-level 1 2. Parallel connection of inductance
frame and 2-section container and capacitor.
9 Accessories Kit 1 3. Three-phase AC electrical circuits.
10 Basic Experiments Guide 1 1. Delta connection of three-phase
Electrical circuits & electrical load.
fundamentals of electronics 2. Star connection of three-phase
electrical load.
11 Basic Experiments Guide 1
3. Failure modes of three-phase
Fundamentals of digital circuit when load connected star.
electronics 4. Failure modes of three-phase
12 Operating manual 1 circuit when load connected delta.
13 Didactic materials CD 1
14 Oscilloscope 1

Page 12
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
3. Magnetic circuits.
Power consumption, VA 50
1. DC Magnetic circuits.
2. AC Magnetic circuits. Power supply:
3. Test of single-phase transformer. - single-phase AC mains with
4. . working neutral and protective wires
1. Single-phase rectifier. - voltage, V 220 22
2. Three-phase bridge-circuit rectifier. - frequency, Hz 50 0,5
3. Controlled rectifiers and transistor controllers. Appliance class I
Total dimensions, mm (assembled)
- length 910
4. Two-stage transistor amplifier.
5. DC voltage stabilizer. - width 850
6. RS-trigger, multivibrator and single-shot trigger. - height 1250
7. Circuits with operational amplifiers. Weight, kg 50
5. Testing basic logical elements. Number of Workplaces 2
6. Assembly and test of simple combinational nodes of digital devices.
1. Combinational node using basic logic elements to implement arbitrary logic
function.
2. Combinational nodes using basic logic elements for experimental
confirmation of logic algebra laws.
3. Single-digit half-adder and adder.
4. Code converter and decoder.
5. Multiplexer and demultiplexer.
3. Assembly and test of sequential nodes of digital devices.
3.1. Triggers.
3.2. Counters.
6. Registers.

Page 13
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
12 Electrical and magnetic circuits 1 Set Unit Prices Total Prices
Components list Type / Model ( Rupiah ) ( Rupiah )
Name Pcs EMC1M-S-K Please Contact Us
1 Module of voltage generators with testing board 1
P I C T U R E
2 Single-phase power supply 1
3 Connector 1
4 Model of long-distance line 1
5 Module of 2 multimeters 1
6 Mini-modules Set Electromagnetic components 1
7 Laboratory table for computer 1
8 Laboratory table with 2-section Storage Container and 1-level frame 1
9 Accessories Kit 1
10 Basic Experiments Guide Electrical and magnetic circuits 1
11 Operating Manual 1
12 Software and Didactic materials CD 1
13 Personal computer 1
P
BASIC EXPERIMENTS
1. Linear DC circuits.
1. Measurements of resistance, current, voltage and electric power in DC circuits.
2. Series connection of resistors.
3. Parallel connection of resistors.
4. Series-parallel connection of resistors.
5. Power transmission from active two-pole circuit to load.
2. AC circuits.
1. Series connection of elements R, L and (sinusoidal current).
2. Frequency characteristics of series resonant circuit.
3. Parallel connection of inductance and capacitor.
4. Frequency characteristics of parallel resonant circuit.

Page 14
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
5. Parameters of inductively connected coils.
6. Circuits with nonsinusoidal applied voltage.
3. Three-phase circuits. ower consumption, VA 350
1. Star connection of three-phase electric load. Power supply:
2. Delta connection of three-phase electrical load. - single-phase AC mains with
3. Failure modes of three-phase circuit when load connected star. working neutral and protective wires
4. Failure modes of three-phase circuit when load connected delta. - voltage, V 220 22
5. Voltage filter of negative-phase sequence.
4. Transients in linear electric circuits. - frequency, Hz 50 0,5
1. Charge and discharge of capacitor. Appliance class I
2. Switching-in and fault in circuit with inductor. Total dimensions, mm (assembled)
3. Transients in circuit with resistors and capacitor. - length 2x910
4. Switching-on and switching-off circuit with inductor. - width 850
5. Transients in R-L-C circuit. - height 1300
5. Quadripoles.
Weight, kg 75
1. Parameters of passive quadripole.
2. Frequency characteristics of quadripole (low-pass filter). Number of Workplaces 2
3. Simplest integral and differential quadripoles.
6. Distributed-element circuits. P
1. Voltage distribution along homogeneous long-distance transmission line.
2. Input resistance of long-distance transmission line as function of its electrical
length and load resistance.
3. Reflected waves.
7. Nonlinear electric and magnetic circuits.
1. Volt-ampere characteristics of nonlinear elements in DC circuit.
2. Linearized parameters of bipolar transistor.
3. DC Magnetic circuits.
4. AC Magnetic circuits.
5. Resonance in series circuit of nonlinear inductor and capacitor.
6. Test of single-phase transformer.
7. Single-phase rectifier.

Page 15
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
13 Electrical and magnetic circuits 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 50 EMC1-S-R Please Contact Us
Power supply: P I C T U R E
- single-phase AC mains with
working neutral and protective wires
- voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1300
Weight, kg 45
Number of Workplaces 2

BASIC EXPERIMENTS
1. Linear DC circuits.
1. Measurements of resistance, current, voltage and electrical power in DC circuits.
2. Series connection of resistors.
3. Parallel connection of resistors.
4. Series-parallel connection of resistors.
5. Power transmission from active two-pole circuit to load.
2. AC circuits.
1. Series connection of elements R, L and (sinusoidal current).
2. Frequency characteristics of series resonant circuit.

Page 16
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
3. Parallel connection of inductance and capacitor.
4. Frequency characteristics of parallel resonant circuit. Name Pcs
5. Parameters of inductively connected coils.
1 Module of voltage generators with testing board 1
6. Circuits with nonsinusoidal applied voltage.
3. Three-phase circuits. 2 Single-phase power supply 1
1. Star connection of three-phase electrical load. 3 Model of long-distance line 1
2. Delta connection of three-phase electrical load. 4 Module of 2 multimeters 1
3. Failure modes of three-phase circuit when load connected star. 5 Wattmeter 1
4. Failure modes of three-phase circuit when load connected delta. 6 Mini-modules Set Electromagnetic components 1
5. Voltage filter of negative-phase sequence. 7 Laboratory table with 2-section Storage Container and 1-level frame 1
4. Transients in linear electrical circuits.
8 Accessories Kit 1
1. Charge and discharge of capacitor.
2. Switching-in and fault in circuit with inductor. 9 Basic Experiments Guide Electrical and magnetic circuits 1
3. Transients in circuit with resistors and capacitor. 10 Operating Manual 1
4. Switching-on and switching-off circuit with inductor. 11 Didactic materials CD 1
5. Transients in R-L-C circuit. 12 Two-channel oscilloscope 1
5. Quadripoles.
1. Parameters of passive quadripole.
2. Frequency characteristics of quadripole (low-pass filter).
3. Simplest integral and differential quadripoles.
6. Distributed-element circuits.
1. Voltage distribution along homogeneous long-distance transmission line.
2. Input resistance of long-distance transmission line as function of its electrical length and load resistance.
3. Reflected waves.
7. Nonlinear electric and magnetic circuits.
1. Volt-ampere characteristics of nonlinear elements in DC circuit.
2. Linearized parameters of bipolar transistor.
3. DC Magnetic circuits.
4. AC Magnetic circuits.
5. Resonance in series circuit of nonlinear inductor and capacitor.
6. Test of single-phase transformer.
7. Single-phase rectifier.

Page 17
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
14 Electrical engineering and fundamentals 1 Set Unit Prices Total Prices
of electronics Type / Model ( Rupiah ) ( Rupiah )
EOE1M-S-K Please Contact Us
P I C T U R E
ower consumption, VA, not more than 1000
Electrical supply:
-three-phase AC circuit with
working neutral and protective leads
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Class of protection against electrical shock I
Overall dimensions, mm, not more than
- length 4x910
- width 850
- height 1600
Weight, Kg, not more than 350

Page 18
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
No. Name Pcs 30 Speed indicator 1
1 Electromechanical set with flywheel (DC machine 101.2, AC machine 102.1 and 1 31 Module of 2 multimeters 1
angular displacement transducer) 32 Voltammeter 1
2 1 33 Multifunctional electrical measuring instrument 1
Three-phase power supply 34 Set of minimodules Electrical and electronic components 1
3 Synchronous machine exciter 1 35 Set of minimodules Transformers 1
4 Single-phase thyristor converter 1 36 Laboratory table with 2-level frame 1
5 Module of voltage generators 1 37 Laboratory table with 2-section storage container and 2-level frame 2
6 Frequency converter 1 38 Laboratory table with computer rack and pullout keyboard shelf and 2-level frame 1
7 Single-phase power supply 1 39 Set of accessories 1
8 Three-pole breaker 4 40 Set of accessories 1
9 Terminal 1 41 Manual Electrical DC circuits 1
10 Testing board 1 42 Manual Electrical AC circuits 1
43 Manual Electronic devices 1
11 Active load 1 44 Manual Electrical machines 1
12 Rotor rheostat of AC machine 1 45 Manual Electrical drive 1
13 Excitation rheostat of DC machine 1 46 Manual Electrical long-distance line 1
14 Line reactor 1 47 Operating instructions 1
15 Capacitance load 1 48 Operating instructions 1
16 Module of synchronizing 1 49 CD with methodical materials 1
17 Rectifier 1 50 CD with methodical materials 1
18 Rheostat 1 51 Personal computer 1
19 Inductive load 1
20 Connector 1
21 Module of digital signals input/output 1
22 Connector 1
23 Three-phase transformer group 2
24 Model of long-distance line 1
25 Adjustable three-phase autotransformer 1
26 Module of regulators 1
27 Module of current-and-voltage sensors 1
28 Voltage and frequency meter 1
29 Synchronous machine torque angle meter 1

Page 19
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS
1.Electric DC circuits. 1.1.1. Parallel capacitor-inductor connection. Current resonance.
1.1. Parameters of electrical DC circuit. 1.1.2. Frequency characteristics of series resonance circuit.
1.2. Ohms law. 1.1.3. Frequency characteristics of parallel resonance circuit.
1.3. Resistor circuits. 1.2. Transformers.
1.3.1. Linear resistors. 1.2.1. Magnetic linkage factor.
1.3.2. Heat-variable resistor with negative temperature factor. 1.2.2. Transformation factor.
1.3.3. Heat-variable resistor with positive temperature factor. 1.2.3. Resistance conversion by means of transformer.
1.3.4. Varistor. 1.3. Three-phase circuits of sinusoidal current.
1.3.5. Photoresistor. 1.3.1. Voltages and currents of three-phase circuit.
1.3.6. Series resistor connection. 1.3.2. Star connection of three-phase electrical load.
1.3.7. Parallel resistor connection. 1.3.3. Delta connection of three-phase electrical load.
1.3.8. Series-parallel resistor connection. 2.6.4. Failure modes of three-phase circuit when load connected star.
1.3.9. Resistance voltage divider. 2.6.5. Failure modes of three-phase circuit when load connected delta.
1.4. Voltage (EMF) source. 1.4. Circuits with nonsinusoidal applied voltage.
1.5. Series connection of voltage (EMF) source. 1.5. Transients in linear circuits.
1.6. Parallel connection of voltage (EMF) source. 1.5.1. Transients in circuit with capacitor and resistors.
1.7. Electric power and energy. 1.5.2. Transients in circuit with inductor.
1.8. Electric circuit efficiency. 1.5.3. Transient in oscillating circuit.
1.9. Voltage, current and power matching between voltage (EMF) source and load.
1.10. Charge and discharge of capacitor.
1.11. Switching-on and switching-off circuit with inductor. 3.Long-distance line.
1.1. Voltage distribution along homogeneous long-distance line.
2.Electric AC circuits. 1.2. Input resistance of long-distance transmission line as function of its electrical length and load resistance.
2.1. Parameters of sinusoidal voltage and current. 1.3. Reflected waves.
2.2. Circuits of sinusoidal current with capacitors
2.2.1. Voltage and current of capacitor.
2.2.2. Imaginary impedance of capacitor. 4.Electronic devices.
2.2.3. Series capacitor connection. 2.1. Rectifier diodes.
2.2.4. Parallel capacitor connection. 2.1.1. Diode characteristics.
2.2.5. Reactive power of capacitor. 2.1.2. Single-phase half-wave uncontrolled rectifier.
2.3. Circuits of sinusoidal current with inductors. 2.1.3. Single-phase bridge-circuit uncontrolled rectifier.
2.3.1. Voltage and current of inductor. 2.1.4. Three-phase bridge-circuit uncontrolled rectifier.
2.3.2. Imaginary impedance of inducitor.
2.3.3. Series inductor connection. 2.1.5. Three-phase zero uncontrolled rectifier.
2.3.4. Parallel inductor connection. 2.2. . Stabilitron.
2.3.5. Reactive power of inductor. 4.2.1. Characteristics.
2.4. Circuits of sinusoidal current with resistors, capacitors and inductors. 4.2.2. Parametric voltage stabilizer.
2.4.1. Series resistor-capacitor connection. 4.2.3. Smoothing ripples of rectified voltage.
2.4.2. Parallel resistor-capacitor connection. 4.3. Diodes with special properties.
2.4.3. Series resistor-inductor connection.
2.4.4. Parallel resistor-inductor connection.

Page 20
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
4.3.1. LED.
4.3.2. Varicap.
4.4. Bipolar transistors.
4.4.1. Testing layers and study of rectifying action of bipolar transistors.
4.4.2. Distribution of current in the transistor and the control effect of the base current of the transistor.
4.4.3. Transistor characteristics.
4.4.4. Setting the operating point of the transistor, and study of effect of resistor in the collector circuit to the voltage gain of the amplifier stage with a common emitter.
4.4.5. Amplifiers using bipolar transistors.
4.4.6. Linear voltage regulator.
4.4.7. Linear current regulator.
4.5. Unipolar (field) transistors.
4.5.1. Testing layers and study of rectifying action of unipolar transistors.
4.5.2. Turn-on of transistor gate.
4.5.3. Control effect of n-type transistor gate.
4.5.4. The output characteristics of transistor. Electric machines
4.5.5. Amplifiers.
4.6. Thyristors. 1. Single-phase transformer.
4.6.1. Characteristics of diode thyristor.
4.6.2. Characteristics of triode thyristor. 1.1. Transformation ratio of single-phase transformer.
4.6.3. Phase control of thyristor. 1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase transformer.
4.7. Logic elements. 1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) single-phase transformer.
4.7.1. Logic element "AND". 1.4. Characteristic U = f (I) single-phase transformer with resistive load.
4.7.2. Logical element "OR". 1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of single-phase transformer with a resistive
4.7.3. Logic element "NOT". load.
4.7.4. Logic element "NAND".
1.6. Determination of equalizing current caused by inequality of transformation ratios of parallel single-phase transformers.
4.7.5. Logic element "NOR".
4.8. Operational amplifiers. 1.7. Effect caused by the inequality of short-circuit voltages of single-phase transformers operating in parallel.
4.8.1. Inverting amplifier. 2. Single-phase autotransformer.
4.8.2. Non-inverting amplifier. 2.1. Transformation ratio of single-phase autotransformer.
4.8.3. Summing amplifier. 2.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) of single-phase autotransformer.
4.8.4. Differential amplifier. 2.3. Characteristic U = f (I) single-phase during resistive load.
4.8.5. Dynamics of operational amplifier.

3. Three-phase transformer.
3.1. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of three-phase transformer.
31.2. Short-circuit characteristics IK = f (U), RC = f (U), cosK = f (U) t of three-phase transformer.
3.3. Checking vector grouping of three-phase transformer.
3.4. Confirmation of impossibility of parallel operation of three-phase transformers with different vector grouping.
4. DC generators with separate / shunt excitation.
4.1. Idling characteristics E0 = f (If) of DC generator with separate excitation.
4.2. Short-circuit characteristics IK = f (If) of DC generator with separate excitation.

Page 21
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
4.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with separate excitation.
4.4. Characteristic U = f (I) of DC generator with shunt excitation.

5. DC motors with separate/ shunt / series excitation.


5.1. Electromechanical (speed) characteristics n = f (I) of DC motor with separate / shunt / series excitation.
5.2. Mechanical characteristics of n = f (M) of DC motor with an separate / shunt / series excitation.
5.3. Operational characteristics n = f (P2), P1 = f (P2), M = f (P2), = f (P2) of DC motor with separate / shunt / series excitation.
5.4. Speed control of DC motor with separate / shunt / series excitation by armature voltage changing.
5.5. Speed control of a DC motor with separate / shunt / series excitation by changing additional resistance in the armature circuit.
5.6. Speed control of a DC motor with separate / shunt excitation by field current change.
5.7. Speed control motor with series excitation by shunting field winding.

6.Three-phase asynchronous generator Electric drives


6.1. Characteristics =f(n), Q=f(n). 1. Mechanics of drives.
6.2. Ideal idling characteristics I0=f(U), Q0=f(U).
1.1. Determination of inertia moment of electric drive by method
6.3. Load characteristics n=f(), I=f(), Q=f(), cos=f(P).
7. Three-phase squirrel-cage induction motor. of free run-out.
7.1. Idling characteristics I0 = f (U), P0 = f (U), cos0 = f (U) . 1.2. Determination of mechanical characteristic of working
7.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) . mechanism.
7.3. Electromechanical (speed) characteristic n = f (I). 1.3. Drive speed as function of time during transient.
7.4. Mechanical characteristic n = f (M). 2. Electric drive using DC motor with separate (shunt, series) excitation.
7.5. Operational characteristics I = f (P2), P1 = f (P2), s = f (P2), = f (P2), cos = f (P2), M = f (P2). 2.1 Determination of electromechanical and mechanical
7.6. Speed control of three-phase squirrel-cage induction motor by stator voltage changing
characteristics of electric drive in motor, generator, and braking modes.
8. Three-phase wound-rotor induction motor. 2.2. Speed control by changing resistance in armature circuit of DC
8.1. Electromechanical (speed) characteristic n = f (I). motor.
8.2. Mechanical characteristic n = f (M). 2.3. Speed control by changing excitation current of DC motor.
8.3. Operational characteristics I = f (P2), P1 = f (P2), s = f (P2), = f (P2), cos = f (P2), M = f (P2). 2.4. Speed control by shunting field winding of DC motor with series
8.4. Speed control of three-phase wound-rotor induction motor by active rotor resistance changing. excitation.
9. Three-phase synchronous generator. 2.5. Speed control by changing armature voltage DC motor.
9.1. Idling characteristic E0=f(If).
9.2. Short-circuit characteristic I=f(If). 2.6. Armature current and speed as function of time during
9.3. Characteristics U = f (I), If = f (I) and U = f (If). transient.
9.4. Ideal synchronization. 2.7. Definition of energy parameters of electric drive with DC motor.
9.5. Self-synchronization. 2.8. Measuring body temperature of DC motor.
9.6. Angle characteristics P=f(), Q=f(), U=f().
9.7. U-curve characteristic I=f(If).
10. Three-phase synchronous motor.
10.1.Asynchronous start.
10.2.U-curve characteristic I=f(If).
10.3. Operational characteristics I=f(P2), P1=f(P2, =f(P2), cos=f(P2), M=f(P2).
10.4. Angle characteristics P=f(), Q=f(), U=f().

Page 22
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
3. Electric drive using squirrel-cage induction motor.
3.1. Electromechanical and mechanical characteristics of electric drive with induction motor in motor, generator, and braking modes.
3.2. Speed control by match changing frequency and magnitude of stator voltage .
3.3. Stator current and speed as function of time during transient.
3.3. Definition of energy parameters of electric drive with induction motor .
3.4. Measurement of body temperature of induction motor.
4. Electric drive using wound-rotor induction motor.
4.1. Electromechanical and mechanical characteristics of electric drive with induction motor in motor, generator, and braking modes.
4.2. Speed control by match changing frequency and magnitude of stator voltage .
4.3. Stator current and speed as function of time during transient.
4.3. Definition of energy parameters of electric drive with induction motor .
4.4. Measurement of body temperature of induction motor.
5. Electric drive using synchronous motor.
5.1. Electromechanical and mechanical characteristics of electric drive with synchronous motor.
5.2. Static angle characteristic.
5.3. Static V-curve characteristic.
5.4. Reactive power control by changing excitation current.
5.5. Stator current and speed as function of time during transient.
5.6. Definition of energy parameters of electric drive with synchronous motor .
5.7. Measurement of body temperature of synchronous motor.

6. Open-loop control of electric drives.


6.1. DC drive startup control in function of time (speed, EMF, armature current) and dynamic braking in function of time (speed, EMF).
6.2. Induction squirrel-cage motor control during direct-on-line startup, reverse and dynamic braking in function of time (plugging).
6.3. Induction wound-rotor motor control during direct-on-line startup in function of time (speed, EMF, stator current), reverse and dynamic braking in function of time (speed, EMF).
6.4. Synchronous motor control of startup and braking.
7. Closed-loop control of electric drives.
7.1. Thyristor converter - DC motor.
7.1.1. Control characteristics.
7.1.2. Current control contour adjustment.
7.1.3. Limiter adjustment.
7.1.4. Speed control contour adjustment.
7.1.5. Determination of static electromechanical and mechanical characteristics.
7.2. Frequency converter - induction motor .
7.2.1. Speed control contour adjustment.
7.2.2. Control characteristics.
7.2.3. Determination of static electromechanical and mechanical characteristics.

Page 23
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
15 Electrical engineering and fundamentals of electronics 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Module / Component Pcs
EOE2M-S-R Please Contact Us
1 Electromechanical set with flywheel (DC machine, AC motor and 1
angular displacement transducer)
P I C T U R E
2 Three-phase power supply 1
3 Single-phase thyristor converter 1
4 Module of voltage generators 1
5 Frequency converter 1
6 Single-phase power supply 2
7 Three-pole breaker 1
8 Testing board 1
9 Active load 1
10 Excitation rheostat of DC machine 1
11 Line reactor 1
12 Adjustable autotransformer 1
13 Rectifier 1
14 Rheostat 1
15 Three-phase transformer group 2
16 Model of long-distance line 1
17 Adjustable three-phase autotransformer 1
18 Speed indicator 1
19 Module of 3 multimeters 1
20 Module of 2 multimeters 1
21 Wattmeter 1
22 Voltammeter 1
23 Multifunctional electrical measuring instrument 1

Page 24
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
27 Laboratory Table with 2-section Storage Container and 1-level Frame 1 2.1. Parallel connection of voltage (EMF) source.
33 Manual Electrical machines 1 2.2. Electrical power and energy..
24 Set of minimodules Electrical and electronic components 1 2.3. Electrical efficiency.
2.4. Voltage, current and power matching between voltage (EMF) source and load.
25 Set of minimodules Transformers 1
2.5. Charge and discharge of capacitor.
26 Laboratory table with 2-section container and 2-level frame 1 AC circuits.
Laboratory Table with Wires Storage Container and 2-level Frame 1 3.1. Parameters of sinusoidal voltage and current.
28 Set of accessories 1 3.2. Circuits of sinusoidal current with capacitors.
29 Set of accessories 1 Voltage and current of capacitor.
30 Manual Electrical DC circuits 1 Imaginary impedance of capacitor.
31 Manual Electrical AC circuits 1 Series capacitor connection.
Parallel capacitor connection.
32 Manual Electronic devices 1
Reactive power of capacitor.
34 Manual Electrical drive 1 3.3. Circuits of sinusoidal current with inductors.
35 Manual Electrical long-distance line 1 Voltage and current of inductor.
36 Operating instructions 1 Imaginary impedance of inducitor.
37 Operating instructions 1 Series inductor connection.
38 CD with methodical materials 1 Parallel inductor connection.Reactive power of inductor
39 Stopwatch 1 3.4. Circuits of sinusoidal current with resistors, capacitors and inductors.
Series resistor-capacitor connection.
Parallel resistor-capacitor connection.
BASIC EXPERIMENTS Series resistor-inductor connection.
Linear DC circuits. Parallel resistor-inductor connection.
1.1. Parameters of electrical DC circuit. Series capacitor-inductor connection. Voltage resonance.
1.2. Ohms law. Parallel capacitor-inductor connection. Current resonance.
1.3. Resistor circuits. Frequency characteristics of series resonance circuit.
Linear resistors. Frequency characteristics of parallel resonance circuit.
Heat-variable resistor with negative temperature factor. 3.5. Transformers.
Heat-variable resistor with positive temperature factor. Magnetic linkage factor.
Varistor. Transformation factor.
Photoresistor. Resistance conversion by means of transformer.
Series resistor connection. 3.6. Three-phase circuits of sinusoidal current.
Parallel resistor connection. Voltages and currents of three-phase circuit.
Series-parallel resistor connection. Star connection of three-phase electrical load. Delta connection of three-phase
Resistance voltage divider. electrical load. .6.4. Failure modes of three-phase circuit when load connected star.
1.4. Voltage (EMF) source. Series connection of voltage (EMF) source.

Page 25
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
2.6.5. Failure modes of three-phase circuit when load connected delta.
1.5. Circuits with nonsinusoidal applied voltage.
1.6. Transients in linear circuits.
Transients in circuit with capacitor and resistors.
Transients in circuit with inductor.
Transient in oscillating circuit.

Long-distance line.
2.1. Voltage distribution along homogeneous long-distance line.
2.2. Input resistance of long-distance transmission line as function of its electrical length and load resistance.
2.3. Reflected waves.
Electronic devices.
3.1. Rectifier diodes.
Diode characteristics.
Single-phase half-wave uncontrolled rectifier.
Single-phase bridge-circuit uncontrolled rectifier.
Three-phase bridge-circuit uncontrolled rectifier.
Three-phase zero uncontrolled rectifier.
3.2. Stabilitron.
4.2.1. Characteristics.
4.2.2. Parametric voltage stabilizer.
4.2.3. Smoothing ripples of rectified voltage.
4.3. Diodes with special properties.
4.3.1. LED.
4.3.2. Varicap.
4.4. Bipolar transistors.
4.4.1. Testing layers and study of rectifying action of bipolar transistors.
4.4.2. Distribution of current in transistor and control effect of base current of transistor.
4.4.3. Transistor characteristics.
4.4.4. Setting the operating point of the transistor, and study of effect of resistor in the collector circuit to the voltage gain of the amplifier stage with a common emitter.
4.4.5. Amplifiers using bipolar transistors.
4.4.6. Linear voltage regulator.
4.4.7. Linear current regulator.
4.5. Unipolar (field) transistors.
4.5.1. Testing layers and study of rectifying action of unipolar transistors.
4.5.2. Turn-on of transistor gate.Control effect of n-type transistor gate.

Page 26
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
4.5.3. The output characteristics of transistor.
4.5.4. Amplifiers.
4.6. Thyristors.
4.6.1. Characteristics of diode thyristor.
4.6.2. Characteristics of triode thyristor.
4.6.3. Phase control of thyristor .
4.7. Logic elements.
4.7.1. Logic element "AND".
4.7.2. Logical element "OR".
4.7.3. Logic element "NOT".
4.7.4. Logic element "NAND".
4.7.5. Logic element "NOR".
4.8. Operational amplifiers.
4.8.1. Inverting amplifier.
4.8.2. Non-inverting amplifier.
4.8.3. Summing amplifier.
4.8.4. Differential amplifier.
4.8.5. Dynamics of operational amplifier
Electrical machines
1. Single-phase transformer.
1.1. Transformation ratio of single-phase transformer.
1.2. Characteristics of idling I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase transformer.
1.3. Characteristics of short-circuit IK = f (U), RK = f (U), cosK = f (U) single-phase transformer.
1.4. Characteristic U = f (I) single-phase transformer with resistive load.
1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of single-phase transformer with a resistive load.
1.6. Determination of equalizing current caused by inequality of transformation ratios of parallel single-phase transformers.
1.7. Effect caused by the inequality of short-circuit voltages of single-phase transformers operating in parallel.
2. Single-phase autotransformer.
2.1. Transformation ratio of single-phase autotransformer.
2.2. Characteristics of short-circuit IK = f (U), RK = f (U), cosK = f (U) of single-phase autotransformer.
2.3. Characteristic U = f (I) single-phase auto-transformer with a resistive load.

3. Three-phase transformer.
3.1. Characteristics of idling I0 = f (U), F0 = f (U), cos0 = f (U) of three-phase transformer.
31.2. Characteristics of short-circuit IK = f (U), RC = f (U), cosK = f (U) t of three-phase transformer.
3.3. Checking vector grouping of three-phase transformer.
3.4. Confirmation of impossibility of parallel operation of three-phase transformers with different vector grouping.

Page 27
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Characteristics of short circuit IK = f (If) of DC generator with independent excitation.
4.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with independent excitation.
4.4. Characteristic U = f (I) of DC generator with shunt excitation.

5. DC motors with separate / parallel / series excitation.


5.1. Electromechanical (speed) characteristics n = f (I) of DC motor with separate / parallel / series excitation.
5.2. Mechanical characteristics of n = f (M) of DC motor with an separate / parallel / series excitation.
5.3. Operational characteristics n = f (P2), P1 = f (P2), M = f (P2), = f (P2) of DC motor with separate / parallel / series excitation.
5.4. Speed control of DC motor with separate / parallel / series excitation by armature voltage changing.
5.5. Speed control of a DC motor with separate / parallel / series excitation by changing additional resistance in the armature circuit.
5.6. Speed control of a DC motor with separate / shunt excitation by field current change.
5.7. Speed control motor with series excitation by shunting field winding.

6. Three-phase asynchronous motor with squirrel-cage rotor.


6.1. Characteristics of idling I0 = f (U), P0 = f (U), cos0 = f (U) .
6.2. Characteristics of short-circuit IK = f (U), RK = f (U), cosK = f (U) .
6.3. Electromechanical (speed) characteristic n = f (I).
6.4. Mechanical characteristic n = f (M) .
6.5. Operational characteristics I = f (P2), P1 = f (P2), s = f (P2), = f (P2), cos = f (P2), M = f (P2) .
6.6. Speed control of three-phase asynchronous squirrel cage induction motor by stator voltage changing
.Electrical drive
1 . The mechanics of the drive.
1.1. Determination of the moment of inertia of the electrical drive by method of free run-out.
1.2. Determination of mechanical characteristic of working mechanism.
2. Electrical drive using DC motor with independent (parallel, series) excitation.
2.1 Determination of electromechanical and mechanical characteristics of electrical drive in motor, generator, and braking modes.
2.2. Speed control by changing resistance in armature circuit of DC motor.
2.3. Speed control by changing texcitation current of DC motor.
2.4. Speed control by shunting field winding of DC motor with series excitation
2.5. Speed control by changing armature voltage DC motor.
2.6. Definition of energy parameters of electrical drive with DC motor.
2.7. Measuring body temperature of DC motor.
3. Electrical drive using induction motor with squirrel cage.
3.1. Electromechanical and mechanical characteristics of electrical drive with induction motor in motor, generator, and braking modes.
3.2. Speed control by match changing frequency and magnitude of stator voltage .
3.3. Definition of energy parameters of electrical drive with induction motor ; Measurement of body temperature of induction motor.
5. DC generators with independent / shunt excitation., Characteristic of idling E0 = f (If) of DC generator with independent excitation.

Page 28
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
16 Electrical engineering and fundamentals of electronics 1 Set Unit Prices Total Prices
Power consumption, VA, not more than 1000
Type / Model ( Rupiah ) ( Rupiah )
Electrical supply: EOE3M-S-K Please Contact Us
- single-phase AC circuit with P I C T U R E
working neutral and protective leads 220 22
- voltage, V
- frequency, Hertz
50 0,5
Class of protection against electrical shock I
Overall dimensions, mm, not more than
- length 3x910
- width 850
- height 1600
Weight, Kg, not more than 250
Number of Workplaces 3

Page 29
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Component / Module Pcs
28 Manual Fundamentals of analog electronics 1
1 Electromechanical set (DC machine 101.1, induction motor 106 and angular 1
29 Manual Single-phase transformer 1
displacement transducer)
30 Manual Electric machines and drives 1
2 Module of voltage generators & testing board 1
31 Manual Electric values measurements 1
3 Frequency converter 1
32 Operating instructions 1
4 Single-phase power supply 1
33 CD with methodical materials 1
5 Module of testing digital devices 1
34 2-channel oscilloscope
6 Active load 1
35 Resistor magazine 1
7 Excitation rheostat of DC machine 1
36 Personal computer 1
8 Adjustable autotransformer 1
9 Rectifier 1
BASIC EXPERIMENTS
10 Connector 1
11 Single-phase transformer 2
Measuring instruments and measurements in electric circuits
12 Module of resistors 1
13 Speed indicator 1
1. Measurements in DC circuits.
14 Module of 3 multimeters 1
1. Direct measurement of voltage and current with analog and digital
15 Module of 2 multimeters 1 instruments.
16 Voltammeter 1 2. Determination of voltage polarity and current direction according to instrument
17 Single-phase circuit parameter meter 1 readings.
18 Mini-modules Set Fundamentals of digit technology 1 3. Indirect measurement of voltage and current.
19 Mini-modules Set Analog electronics - Electric elements 1 4. Expansion of ammeter and voltmeter measurement limits via shunts and
20 Mini-modules Set Analog electronic - Electronic elements 1 additional resistances.
5. Calibration of analog ammeter and voltmeter.
21 Mini-modules Set Electromagnetic elements 1
6. Determination of methodic measurement error due to instrument influence.
22 Laboratory table with 2-section storage container and 2-level frame 1 7. Assessment of analog and digital instrument resistances.
23 Laboratory table with computer rack and pullout keyboard shelf 1 8. Measurement of source EMF with a high internal resistance by compensation
24 Laboratory table with container for conductors and 2-level frame 1 method.
25 Set of accessories 1 2. Measurements in AC circuits.
26 Manual Fundamentals of digit technology 1 1. Direct measurements of sinusoidal voltage and current.
27 Manual Electric and magnetic circuits 1 2. Estimation of the upper boundary of measuring instrument frequency range.
3. Measuring power in DC circuit.
1. Indirect measurement of power by voltmeter-ammeter method.

Page 30
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1. Measuring electric resistance in DC circuits.
1. Direct measurement of electric resistance with analog and digital instruments. 4.1. Study of the simplest differentiating and integrating
2. Indirect measurement of electrical resistance by ammeter and voltmeter. quadripoles.
3. Determination of methodic error of electrical resistance measurement caused by instrument influence 5. Nonlinear electric and magnetic circuits..
4. Assembling and testing bridge electrical resistance measurement circuit. 5.1. Finding current-voltage characteristics of nonlinear DC
5. Measuring electrical resistance by equal-arm and nonequal-arm balanced bridges. elements.
6. Measuring electrical resistance by transfer method. 5.2. Defining parameters of the equivalent linearized transfer
circuit of bipolar transistor.
Electric and magnetic circuits 5.3. Experimental study and calculation of DC magnetic circuit.
5.4. Experimental study of AC magnetic circuit.
1. Linear DC circuits. 5.5. Study of resonance in circuit with series connected
1.1. Measuring resistors, currents and voltages in DC circuits. nonlinear inductor and capacitor.
1.2. Series resistor connection. 5.6. Study of single-phase transformer.
1.3. Parallel resistor connection. 5.7. Study of single-phase rectifiers.
1.4. Series-parallel resistor connection. Fundamentals of analog electronics
1.5. Power transfer from active two-terminal to load.
2. AC circuits. 1. Semiconductors.
2.1. Sinusoidal current circuit with series connection of R, L and C. 1.1. Characteristics of semiconductor diodes for direct and
2.2. Frequency characteristics of series resonance contour. alternating currents.
2.3. Parallel capacitor-inductor connection. 1.2. Main characteristics of stabilitron and study of parametric
2.4. Frequency characteristics of parallel resonance contour. voltage regulator.
2.5. Defining parameters of inductively coupled coils. 1.3. Current-voltage characteristics of LED.
2.6. Calculation and experimental study of electric circuit at nonsinusoidal applied voltage. 1.4. Variable capacitance diode (varicap).
3. Three-phase AC circuits. 1.5. Test of p-n junctions of bipolar transistor and receiving its
3.1. Star connection of three-phase electric load. output characteristics with an oscilloscope.
3.2 Delta connection of three-phase electrical load. 1.6. Static characteristics of transistor for direct current.
3.3. Failure modes of three-phase circuit when load connected star. 1.7. Choice of bipolar transistor operating point and familiarization
3.4. Failure modes of three-phase circuit when load connected delta. with AC voltage amplification mode of classes A, B, AB, and D.
3.5. Study of negative phase-sequence filter. 1.8. Static characteristics of a field-effect transistor with p-n
4. Transients in linear electric circuits. junction.
4.1. Study of capacitor charge-discharge. 1.9. Static characteristics of field-effect transistor, insulated gate
4.2. Study of transient in inductor under voltage switching-in and short-circuiting. and induced channel.
4.3. Study of transient in circuit with capacitor and resistors. 1.10. Main characteristics of thyristors.
4.4. Transients during switching-in and switching-off in circuit with inductor. 1.11. Basic characteristics and parameters of photocouplers.
4.5. Transients in R-L-C contour.
5. Quadripoles.
5.1. Determining passive quadripole parameters. Experimental finding quadripole (low-pass filter) frequency characteristics.

Page 31
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1. Assembly and test of sequential nodes of digital devices.
1. Electronic circuits and microcircuitry.
1. Triggers.
1.1. Comparative study of single amplifier stages using bipolar transistors.
2. Counters.
2.2. Study of amplifier stages using FET.
3. Registers.
2.3. Study of two-stage transistor amplifier.
Electric machines and drives
2.4. Study of push-pull power amplifier using bipolar transistors.
2.5. Study of the basic circuits of operational amplifier.
2.6. Defining frequency characteristics of operational amplifier. 1. Single-phase transformer.
2.7. Summation, integration and differentiation schemes on operational amplifiers. 1.1. Transformation ratio of single-phase transformer.
2.8. RC-filter using operational amplifier. 1.2. Characteristics of idling I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase
2.9.Simple logarithmic converter using operational amplifier. transformer.
2.10.Generator of sinusoidal oscillations using operational amplifier. 1.3. Characteristics of short-circuit IK = f (U), RK = f (U), cosK = f (U) single-
2.11. Schmitt trigger and relaxation oscillators using operational amplifier. .
2.12. RS-trigger, multivibrator and single-shot trigger. phase transformer.
2.13. Analog integrated comparators and circuits with them. 1.4. Characteristic U = f (I) single-phase transformer with resistive load.
2.14. Self-oscillating and standby modes of analog timer using integrated chip. 1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of
2.15. Generator of special form voltage (function generator) using integrated chip. single-phase transformer with a resistive load.
2.DC generators with separate excitation.
3. Stabilizers and secondary sources of supply. 2.1. Characteristic of idling E0 = f (If) of DC generator with separate
3.1. Half-wave and bridge-circuit rectifiers.
excitation.
3.2. Three-phase bridge-circuit rectifier and smoothing filters.
3.3. Controlled rectifiers and thyrister regulator with phase control. 2.2. Characteristics of short circuit IK = f (If) of DC generator with
3.4. Degenerative voltage and current stabilizers. separate excitation.
3.5. Main schemes of coupling linear integral voltage regulator. 2.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with
3.6. PWM DC-DC converter. separate excitation.
3.7. Integral pulse converter - voltage stabilizer with pulse-frequency modulation. 3.DC motor with shunt excitation and electric drive on its bases.
3.1. Electromechanical (speed) characteristics n = f (I).
Fundamentals of digit electronics
1.1. Mechanical characteristics n = f (M).
1.2. Speed control of DC motor with shunt excitation by armature voltage
1. Testing basic logical elements.
changing.
2. Assembly and test of simple combinational nodes of digital devices.
1.3. Speed control of DC motor with shunt excitation by field current changing.
1. Combinational node using basic logic elements to implement arbitrary logic function.
1.4. Determination of coordinates of electric drive with DC shunt motor in
2. Combinational nodes using basic logic elements for experimental
generator, motor and braking modes.
3. confirmation of logic algebra laws.
1.5. Mechanical characteristics n = f (M).
4. Single-digit half-adder and adder.
5. Code converter and decoder. Multiplexer and demultiplexer

Page 32
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
4. Three-phase induction squirrel-cage motor and electric drive on its bases.
4.1. Electromechanical (speed) characteristics n = f (I).
4.3.Speed control by match changing frequency and magnitude of stator voltage ..
4.4. Determination of coordinates of electric drive with induction squirrel-cage motor in generator, motor and braking modes.

Page 33
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
17 Electric engineering and fundamentals of electronics 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Name Pcs
EOE4M-S-K Please Contact Us
1 Electromechanical set (DC machine 101.1, induction motor 106 and angular 1
displacement transducer) P I C T U R E
2 Module of voltage generators & testing board 1
3 Frequency converter 1
4 Single-phase power supply 1
5 Active load 1
6 Excitation rheostat of DC machine 1
7 Adjustable autotransformer 1
8 Rectifier 1
9 Speed indicator 1
10 Module of 3 multimeters 1
11 Wattmeter 1
12 Voltammeter 1
13 Mini-modules Set Electric and electronic elements 1
14 Laboratory table with 2-section storage container and 3-level frame 1
15 Set of accessories 1
16 Manual Electric engineering and electronics 1
17 Manual Electric machines and drives 1
18 Operating instructions 1
19 Operating instructions for USB oscilloscope 1
20 CD with methodical materials 1
21 USB oscilloscope DSO 2090 or analog 1
22 Notebook 1
Component List

Page 34
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS Electric machines and drives
Electric and magnetic circuit
1. DC generators with separate excitation.
1. DC circuits. 1.1. Characteristic of idling E0 = f (If) of DC generator with separate excitation.
1. Measuring resistors, currents and voltages in DC circuits. 1.2. Characteristics of short circuit IK = f (If) of DC generator with separate excitation.
2. Series resistor connection.
1.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with separate excitation.
3. Parallel resistor connection.
4. Series-parallel resistor connection.
5. Ampere-volt characteristics of nonlinear DC element. 3.DC motor with shunt excitation and electric drive on its bases.
2. AC circuits. 3.1. Electromechanical (speed) characteristics n = f (I).
1. Sinusoidal current circuit with series connection of R, L and C. 3.2.Mechanical characteristics n = f (M).
2. Parallel capacitor-inductor connection. 3.3. Speed control of DC motor with shunt excitation by armature voltage changing.
3. Three-phase AC circuits. . 3.4. Speed control of DC motor with shunt excitation by field current changing.
1. Star connection of three-phase electric load. 3.5. Determination of coordinates of electric drive with DC shunt motor in generator, motor
3.3 . Delta connection of three-phase electrical load. and braking modes.
4.3. Failure modes of three-phase circuit when load connected star. 4. Three-phase induction squirrel-cage motor and electric drive on its bases.
4.4. Failure modes of three-phase circuit when load connected delta. 4.1. Electromechanical (speed) characteristics n = f (I).
4. Magnetic circuits. 4.2. Mechanical characteristics n = f (M).
5.2. Experimental study and calculation of DC magnetic circuit. . 4.3.Speed control by match changing frequency and magnitude of stator voltage ..
5.3. Experimental study of AC magnetic circuit. 4.4. Determination of coordinates of electric drive with induction squirrel-cage motor in generator,
5.4. Study of single-phase transformer. motor and braking modes.

Fundamentals of electronics

1. Single-phase rectifiers..
2.
3. Three-phase bridge-circuit rectifier.
4. Controlled rectifiers and transistor regulators.
5. Two-stage transistor amplifier.
6. DC voltage stabilizers.
7. RS-trigger, multivibrator and single-shot trigger.
8. Circuits with operational amplifiers.

Page 35
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
18 Electric engineering and fundamentals of electronics 1 Set Unit Prices Total Prices
Module / Component Pcs
Type / Model ( Rupiah ) ( Rupiah )
1 Electromechanical set (DC machine 101.1, induction motor 106 and 1 EOE4M-S-R Please Contact Us
angular displacement transducer) P I C T U R E
2 Module of voltage generators & testing board 1
3 Frequency converter 1
4 Single-phase power supply 1
5 Active load 1
6 Excitation rheostat of DC machine 1
7 Adjustable autotransformer 1
8 Rectifier 1
9 Speed indicator 1
10 Module of 3 multimeters 1
11 Wattmeter 1
12 Voltammeter 1
13 Mini-modules Set Electric and electronic elements 1
14 Laboratory table with 2-section storage container and 3-level frame 1
15 Set of accessories 1
16 Manual Electric circuits and electronics 1
17 Manual Electric machines and drives 1
18 Operating instructions 1
19 CD with methodical materials 1
20 Single-channel oscilloscope 1

Page 36
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS
Electric and magnetic circuit
2. DC generators with separate excitation.
1.1. Characteristic of idling E0 = f (If) of DC generator with separate excitation.
4. DC circuits.
1. Measuring resistors, currents and voltages in DC circuits. 1.2. Characteristics of short circuit IK = f (If) of DC generator with separate excitation.
2. Series resistor connection. 1.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with separate excitation.
3. Parallel resistor connection.
4. Series-parallel resistor connection. 3.DC motor with shunt excitation and electric drive on its bases.
5. Ampere-volt characteristics of nonlinear DC element. 3.1. Electromechanical (speed) characteristics n = f (I).
5. AC circuits. 3.2.Mechanical characteristics n = f (M).
1. Sinusoidal current circuit with series connection of R, L and C.
4.3. Speed control of DC motor with shunt excitation by armature voltage changing.
2. Parallel capacitor-inductor connection.
4.4. Speed control of DC motor with shunt excitation by field current changing.
6. Three-phase AC circuits. .
4.5. Determination of coordinates of electric drive with DC shunt motor in generator, motor and
1. Star connection of three-phase electric load.
braking modes.
3.4 . Delta connection of three-phase electrical load. 5. Three-phase induction squirrel-cage motor and electric drive on its bases.
4.5. Failure modes of three-phase circuit when load connected star. 4.3. Electromechanical (speed) characteristics n = f (I).
4.6. Failure modes of three-phase circuit when load connected delta. 4.4. Mechanical characteristics n = f (M).
4. Magnetic circuits. 4.3.Speed control by match changing frequency and magnitude of stator voltage ..
5.5. Experimental study and calculation of DC magnetic circuit. . 4.5. Determination of coordinates of electric drive with induction squirrel-cage motor in generator,
5.6. Experimental study of AC magnetic circuit. motor and braking modes.
5.7. Study of single-phase transformer.

Fundamentals of electronics

9. Single-phase rectifiers..
10.
11. Three-phase bridge-circuit rectifier.
12. Controlled rectifiers and transistor regulators.
13. Two-stage transistor amplifier.
14. DC voltage stabilizers.
15. RS-trigger, multivibrator and single-shot trigger.
16. Circuits with operational amplifiers.

Electric machines and drives

Page 37
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
19 Physical fundamentals of electronics 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 200
Power supply:
FOE1-S-R Please Contact Us
- single-phase AC mains with P I C T U R E
working neutral and protective wires
- voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1250
Weight, kg 35
Number of Workplaces 2

Name Pcs
1 Module of voltage generators with testing board 1
2 Single-phase power supply 1
3 Module of 2 multimeters 1
4 Mini-modules Set Fundamentals of digit technology 1
5 Mini-modules Set Fundamentals of digit technology 1
6 Mini-modules Set Analog electronics - Electric components 1
7 Mini-modules Set Analog electronics - Electronic components 1
8 Laboratory table with container and 1-level frame 1
9 Accessories Kit 1
10 Basic Experiments Guide Fundamentals of digit technology 1
11 Basic Experiments Guide Fundamentals of analog technology 1 13 Didactic materials CD 1
12 Operating manual 1 14 Two-channel oscilloscope 1

Page 38
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS
Fundamentals of analog electronics

2. Semiconductors.
2.1. Characteristics of semiconductor diodes for direct and alternating currents.
2.2. Main characteristics of stabilitron and study of parametric voltage regulator.
2.3. Current-voltage characteristics of LED.
2.4. Variable capacitance diode (varicap).
2.5. Test of p-n junctions of bipolar transistor and receiving its output characteristics with an oscilloscope.
2.6. Static characteristics of transistor for direct current.
2.7. Choice of bipolar transistor operating point and familiarization with AC voltage amplification mode of classes A, B, AB, and D.
2.8. Static characteristics of a field-effect transistor with p-n junction.
2.9. Static characteristics of field-effect transistor, insulated gate and induced channel.
2.10. Main characteristics of thyristors.
2.11. Basic characteristics and parameters of photocouplers.
3. Electronic circuits and microcircuitry.
3.1. Integral pulse converter - voltage stabilizer with pulse-frequency modulation.
3.1. Comparative study of single amplifier stages using bipolar transistors.
2.2. Study of the amplifier stages using FET.
2.3. Study of two-stage transistor amplifier.
2.4. Study of the basic circuits of operational amplifier. Fundamentals of digit electronics
2.5. Removing the frequency characteristics of operational amplifier.
2.6. Summation, integration and differentiation schemes on operational amplifiers. 4. Testing basic logical elements.
2.7. RC-filter using operational amplifier. 5. Assembly and test of simple combinational nodes of digital devices.
2.8. Simple logarithmic converter using operational amplifier. 1. Combinational node using basic logic elements to implement arbitrary logic
2.9. Generator of sinusoidal oscillations using operational amplifier. function.
2.10. Schmitt trigger and relaxation oscillators using operational amplifier. . 2. Combinational nodes using basic logic elements for experimental confirmation of
2.11. RS-trigger, multivibrator and single-shot trigger. logic algebra laws.
2.12. Analog integrated comparators and circuits with them. 6. Assembly and test of sequential nodes of digital devices.
2.13. Self-oscillating and standby modes of analog timer using integrated chip. 1. Triggers.
2.14. Generator of special form voltage (function generator) using integrated chip. 2. Counters.

3. Stabilizers and secondary sources of supply.


3.8. Half-wave and bridge-circuit rectifiers.
3.9. Three-phase bridge-circuit rectifier and smoothing filters.
3.10. Controlled rectifiers and thyrister regulator with phase control.
3.11. Degenerative voltage and current stabilizers.
3.12. Main schemes of coupling linear integral voltage regulator. PWM DC-DC converter.

Page 39
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
20 Fundamentals of digit technology 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 50
Power supply: OCT1-N-R Please Contact Us
- single-phase AC mains with P I C T U R E
working neutral and protective wires
- voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 530
- width 500
- height 400
Weight, kg 10
Number of Workplaces 2

Name Pcs
1 Single-phase power supply 1
2 Module of testing digital devices 1
3 Mini-modules Set Fundamentals of digit technology 1
6 Desktop container with 1-level frame (length 530 mm) 1
7 Accessories Kit 1
8 Basic Experiments Guide Fundamentals of digit 1 8. Testing basic logical elements.
technology 9. Assembly and test of simple combinational nodes of digital devices.
11 Operating manual 1 1. Combinational node using basic logic elements to implement arbitrary logic
12 Didactic materials CD 1 function. ; Combinational nodes using basic logic elements for experimental
confirmation of logic algebra laws. ; Single-digit half-adder and adder ; Code
BASIC EXPERIMENTS converter and decoder.
7. Description of laboratory complex Fundamentals of digit electronics. 2. Multiplexer and demultiplexer.
1. Module of testing digital devices. ;Mini-modules sets. 10. Assembly and test of sequential nodes of digital devices.
2. Power supply of laboratory complex. 1. Triggers. ; Counters. ; Registers.

Page 40
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
21 Fundamentals of digit technology 1 Set Unit Prices Total Prices
Name Pcs
Type / Model ( Rupiah ) ( Rupiah )
1 Single-phase power supply 1 OE2-S-R Please Contact Us
2 Module of testing digital devices 1 P I C T U R E
3 Mini-modules Set Fundamentals of digit technology 1
4 Mini-modules Set Fundamentals of digit technology 1
5 Desktop container with 1-level frame (length 600 mm) 1
6 Accessories Kit 1
7 Basic Experiments Guide Fundamentals of digit technology 1
8 Basic Experiments Guide Fundamentals of digit technology 1
9 Operating manual 1
10 Didactic materials CD 1
11 Multimeter 1
BASIC EXPERIMENTS
1. Description of laboratory complex Fundamentals of digit electronics.
2. Module of testing digital devices. ;Mini-modules sets. Power supply of laboratory
complex.
2. Testing basic logical elements.
3. Assembly and test of simple combinational nodes of digital devices.
a. Combinational node using basic logic elements to implement arbitrary
logic function. ; Combinational nodes using basic logic elements for
experimental confirmation of logic algebra laws. ; Single-digit half-adder
and adder; Code converter and decoder ; Multiplexer and demultiplexer. Power consumption, VA 50
4. Assembly and test of sequential nodes of digital devices. Power supply:
a. Triggers.; Counters. ; Registers.
- single-phase AC mains with
5. Assembly and test of digital-to-analog converter.
a. Digital-to-analog converter with current output. ; Digital-to-analog working neutral and protective wires
converter with voltage output.; Codes comparison ; Pulse-length - voltage, V 220 22
modulator. - frequency, Hz 50 0,5
6. Assembly and test of analog-digital converter. - Total dimensions, mm (assembled) length : 600, width : 500 ; height 400
a. Analog comparator. ;Analog-digital converter of sweep conversion.
b. Analog-digital converter of tracing conversion. Weight, kg 10
c. Analog-digital converter of successive approximation.

Page 41
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
22 Fundamentals of electronics 1 Set Unit Prices Total Prices
Name Pcs Type / Model ( Rupiah ) ( Rupiah )
1 Module of voltage generators with testing board 1 OE1-N-R Please Contact Us
2 Single-phase power supply 1 P I C T U R E
3 Module of testing digital devices 1
4 Module of 2 multimeters 1
5 Mini-modules Set Fundamentals of digit technology 1
6 Mini-modules Set Fundamentals of digit technology 1
7 Mini-modules Set Analog electronics - Electric components 1
8 Mini-modules Set Analog electronics - Electronic components 1
9 Desktop container with 1-level frame (length 910 mm) 1
10 Accessories Kit 1
11 Basic Experiments Guide Fundamentals of digit technology 1
12 Basic Experiments Guide Fundamentals of digit technology 1
13 Basic Experiments Guide Fundamentals of analog technology 1
14 Operating manual 1
15 Didactic materials CD 1
16 Two-channel oscilloscope 1
17 Multimeter 1
Power consumption, VA 200
Power supply:
- single-phase AC mains with working neutral and 220 22
protective wires - voltage, V - frequency, Hz 50 0,5

Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 500
- height 400
Weight, kg 20

Page 42
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS

Fundamentals of analog electronics


1. Semiconductors.
3.2. Characteristics of semiconductor diodes for direct and alternating currents.
3.3. Main characteristics of stabilitron and study of parametric voltage regulator.
3.4. Current-voltage characteristics of LED.
3.5. Variable capacitance diode (varicap).
3.6. Test of p-n junctions of bipolar transistor and receiving its output characteristics with an oscilloscope.
3.7. Static characteristics of transistor for direct current.
3.8. Choice of bipolar transistor operating point and familiarization with AC voltage amplification mode of classes A, B, AB, and D.
3.9. Static characteristics of a field-effect transistor with p-n junction.
3.10. Static characteristics of field-effect transistor, insulated gate and induced channel.
3.11. Main characteristics of thyristors. 3.2. Integral pulse converter - voltage stabilizer with pulse-frequency modulation.
3.12. Basic characteristics and parameters of photocouplers. Fundamentals of digit electronics
4. Electronic circuits and microcircuitry. 11. Description of laboratory complex Fundamentals of digit electronics.
4.1. Comparative study of single amplifier stages using bipolar transistors. 1. Module of testing digital devices. ;M ini-modules sets.
2.2. Study of the amplifier stages using FET. 2. Power supply of laboratory complex.
2.3. Study of two-stage transistor amplifier. 12. Testing basic logical elements.
2.4. Study of the basic circuits of operational amplifier. 13. Assembly and test of simple combinational nodes of digital devices.
2.5. Removing the frequency characteristics of operational amplifier. 1. Combinational node using basic logic elements to implement arbitrary logic function.
2.6. Summation, integration and differentiation schemes on operational amplifiers. 2. Combinational nodes using basic logic elements for experimental confirmation of
3.7. RC-filter using operational amplifier. logic algebra laws.
3.8. Simple logarithmic converter using operational amplifier. 3. Single-digit half-adder and adder.
3.9. Generator of sinusoidal oscillations using operational amplifier. 4. Code converter and decoder.
3.10. Schmitt trigger and relaxation oscillators using operational amplifier. . 5. Multiplexer and demultiplexer.
3.11. RS-trigger, multivibrator and single-shot trigger. 14. Assembly and test of sequential nodes of digital devices.
3.12. Analog integrated comparators and circuits with them. 1. Triggers.; Counters. ; Registers.
3.13. Self-oscillating and standby modes of analog timer using integrated chip. 15. Assembly and test of digital-to-analog converter.
3.14. Generator of special form voltage (function generator) using integrated chip. 1. Digital-to-analog converter with current output.; Digital-to-analog converter with
voltage output.; Codes comparison. ; Pulse-length modulator.
4. Stabilizers and secondary sources of supply. 16. Assembly and test of analog-digital converter.
a. Half-wave and bridge-circuit rectifiers. 1. Analog comparator.; Analog-digital converter of sweep conversion.
b. Three-phase bridge-circuit rectifier and smoothing filters. 2. Analog-digital converter of tracing conversion.
c. Controlled rectifiers and thyrister regulator with phase control. 3. Analog-digital converter of successive approximation.
d. Degenerative voltage and current stabilizers.
e. Main schemes of coupling linear integral voltage regulator.PWM DC-DC converter.

Page 43
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
23 Fundamentals of electronics 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Module / Component Pcs OE1-S-R Please Contact Us
1 Module of voltage generators with testing board 1 P I C T U R E
2 Single-phase power supply 1
3 Module of testing digital devices 1
4 Module of 2 multimeters 1
5 Mini-modules Set Fundamentals of digit technology 1
6 Mini-modules Set Fundamentals of digit technology 1
7 Mini-modules Set Analog electronics - Electric components 1
8 Mini-modules Set Analog electronics - Electronic components 1
9 Laboratory table with container and 1-level frame 1
10 Accessories Kit 1
11 Basic Experiments Guide Fundamentals of digit technology 1
12 Basic Experiments Guide Fundamentals of digit technology 1
13 Basic Experiments Guide Fundamentals of analog technology 1
14 Operating manual 1
15 Didactic materials CD 1
16 Two-channel oscilloscope 1
17 Multimeter Mastech MY65 1

Page 44
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Power consumption, VA 200 1.12. Static characteristics of a field-effect transistor with p-n junction.
Power supply: 1.13. Static characteristics of field-effect transistor, insulated gate and induced channel.
- single-phase AC mains with 1.14. Main characteristics of thyristors.
1.15. Basic characteristics and parameters of photocouplers.
working neutral and protective wires
2. Electronic circuits and microcircuitry.
- voltage, V 220 22 2.1. Comparative study of single amplifier stages using bipolar transistors.
- frequency, Hz 50 0,5 2.2. Study of the amplifier stages using FET.
Appliance class I 2.3. Study of two-stage transistor amplifier.
Total dimensions, mm (assembled) 2.4. Study of the basic circuits of operational amplifier.
- length 910 2.5.Finding frequency characteristics of operational amplifier.
- width 850 2.6. Summation, integration and differentiation schemes on operational amplifiers.
- height 1300 2.7. RC-filter using operational amplifier.
Weight, kg 50 2.8. Simple logarithmic converter using operational amplifier.
Number of Workplaces 2 2.9. Generator of sinusoidal oscillations using operational amplifier.
2.10. Schmitt trigger and relaxation oscillators using operational amplifier. .
2.11. RS-trigger, multivibrator and single-shot trigger.
BASIC EXPERIMENTS
2.12. Analog integrated comparators and circuits with them.
2.13. Self-oscillating and standby modes of analog timer using integrated chip.
Fundamentals of analog electronics 2.14. Generator of special form voltage (function generator) using integrated chip.

3. Semiconductors. 3. Stabilizers and secondary sources of supply.


3.1. Characteristics of semiconductor diodes for direct and 3.3. Half-wave and bridge-circuit rectifiers.
alternating currents. 3.4. Three-phase bridge-circuit rectifier and smoothing filters.
3.2. Main characteristics of stabilitron and study of parametric 3.5. Controlled rectifiers and thyrister regulator with phase control.
voltage regulator. 3.6. Degenerative voltage and current stabilizers.
3.3. Current-voltage characteristics of LED. 3.7. Main schemes of coupling linear integral voltage regulator.
3.4. Variable capacitance diode (varicap). 3.8. PWM DC-DC converter.
3.5. Test of p-n junctions of bipolar transistor and receiving its 3.9. Integral pulse converter - voltage stabilizer with pulse-frequency modulation.
output characteristics with an oscilloscope. 17. Assembly and test of digital-to-analog converter.
3.6. Static characteristics of transistor for direct current. 1. Digital-to-analog converter with current output.
3.7. Choice of bipolar transistor operating point and 2. Digital-to-analog converter with voltage output.
familiarization with AC voltage amplification mode of classes 3. Codes comparison.
A, B, AB, and D.

Page 45
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Fundamentals of digit electronics

1. Description of laboratory complex Fundamentals of digit electronics.


1. Module of testing digital devices.
2. Mini-modules sets.
3. Power supply of laboratory complex.
2. Testing basic logical elements.
3. Assembly and test of simple combinational nodes of digital devices.
1. Combinational node using basic logic elements to implement arbitrary logic function.
2. Combinational nodes using basic logic elements for experimental confirmation of logic algebra laws.
3. Single-digit half-adder and adder.
4. Code converter and decoder.
5. Multiplexer and demultiplexer.
4. Assembly and test of sequential nodes of digital devices.
1. Triggers.
2. Counters.
3. Registers.
4. Pulse-length modulator.
5. Assembly and test of analog-digital converter.
1. Analog comparator.
2. Analog-digital converter of sweep conversion.
3. Analog-digital converter of tracing conversion.
4. Analog-digital converter of successive approximation.

Page 46
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
24 Fundamentals of electronics 1 Set Unit Prices Total Prices
Name Pcs
Type / Model ( Rupiah ) ( Rupiah )
1 Module of voltage generators with testing board 1 OE2-S-R Please Contact Us
2 Single-phase power supply 1 P I C T U R E
3 Module of testing digital devices 1
4 Module of 2 multimeters 1
5 Mini-modules Set Fundamentals of digit technology 1
6 Mini-modules Set Fundamentals of digit technology 1
7 Mini-modules Set Fundamentals of digit technology 1
8 Mini-modules Set Analog electronics - Electrical components 1
9 Mini-modules Set Analog electronics - Electronic components 1
10 Laboratory table with 2-section Storage Container and 1-level frame 1
11 Accessories Kit 1
12 Basic Experiments Guide Fundamentals of digit technology 1
13 Basic Experiments Guide Fundamentals of digit technology 1
14 Basic Experiments Guide Fundamentals of digit technology 1
15 Basic Experiments Guide Fundamentals of analog technology 1
16 Operating manual 1
17 Didactic materials CD 1
18 Two-channel oscilloscope 1
19 Multimeter Mastech MY65 1

Page 47
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Power consumption, VA 200
3.8. with AC voltage amplification mode of classes A, B, AB, and D.
Power supply: 3.9. Static characteristics of a field-effect transistor with p-n junction.
- single-phase AC mains with 3.10. Static characteristics of field-effect transistor, insulated gate and induced channel.
working neutral and protective wires 3.11. Main characteristics of thyristors.
- voltage, V 220 22 Basic characteristics and parameters of photocouplers.
- frequency, Hz 50 0,5 4. Electronic circuits and microcircuitry.
Appliance class I 4.1. Comparative study of single amplifier stages using bipolar transistors.
Total dimensions, mm (assembled) 2.2. Study of the amplifier stages using FET.
- length 910 2.3. Study of two-stage transistor amplifier.
- width 2.4. Study of the basic circuits of operational amplifier.
- height 850 2.5. Removing the frequency characteristics of operational amplifier.
1300 2.6. Summation, integration and differentiation schemes on operational amplifiers.
Weight, kg 40 3.7. RC-filter using operational amplifier.
3.8. Simple logarithmic converter using operational amplifier.
Number of Workplaces 2
3.9. Generator of sinusoidal oscillations using operational amplifier.
3.10. Schmitt trigger and relaxation oscillators using operational amplifier. .
3.11. RS-trigger, multivibrator and single-shot trigger.
3.12. Analog integrated comparators and circuits with them.
BASIC EXPERIMENTS 3.13. Self-oscillating and standby modes of analog timer using integrated chip.
3.14. Generator of special form voltage (function generator) using integrated chip.
Fundamentals of analog electronics
4. Stabilizers and secondary sources of supply.
5. Semiconductors. 3.10. Half-wave and bridge-circuit rectifiers.
5.1. Characteristics of semiconductor diodes for direct and 3.11. Three-phase bridge-circuit rectifier and smoothing filters.
alternating currents. 3.12. Controlled rectifiers and thyrister regulator with phase control.
5.2. Main characteristics of stabilitron and study of parametric 3.13. Degenerative voltage and current stabilizers.
voltage regulator. 3.14. Main schemes of coupling linear integral voltage regulator.
5.3. Current-voltage characteristics of LED. 3.15. PWM DC-DC converter.
5.4. Variable capacitance diode (varicap). 3.16. Integral pulse converter - voltage stabilizer with pulse-frequency modulation.
5.5. Test of p-n junctions of bipolar transistor and receiving its
output characteristics with an oscilloscope.
5.6. Static characteristics of transistor for direct current.
5.7. Choice of bipolar transistor operating point and familiarization
5.8.

Page 48
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Fundamentals of digit electronics
6. Testing basic logical elements.
7. Assembly and test of simple combinational nodes of digital devices.
1. Combinational node using basic logic elements to implement arbitrary logic function.
2. Combinational nodes using basic logic elements for experimental confirmation of logic algebra laws.
3. Single-digit half-adder and adder.
4. Code converter and decoder.
5. Multiplexer and demultiplexer.
8. Assembly and test of sequential nodes of digital devices.
1. Triggers.
2. Counters.
3. Registers.
9. Assembly and test of digital-to-analog converter.
1. Digital-to-analog converter with current output.
2. Digital-to-analog converter with voltage output.
3. Codes comparison.
4. Pulse-length modulator.
10. Assembly and test of analog-digital converter.
1. Analog comparator.

2. Analog-digital converter of sweep conversion.


3. Analog-digital converter of tracing conversion.
4. Analog-digital converter of successive approximation.
Assembly and test of multivibrators.
1.1. Test of chip in multivibrators modes.
1.2. Test of timer in multivibrator modes.
2. Assembly and test of storages.
3. Assembly and test of parity control schemes.
4. Circuitry of logic elements.

Page 49
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
25 Theory of electrical circuits & fundamentals of electronics 1 Set Unit Prices Total Prices
Module / Component Pcs Type / Model ( Rupiah ) ( Rupiah )
1 Module of voltage generators 1 TECOE2-S-R Please Contact Us
2 Single-phase power supply 1 P I C T U R E
3 Testing board 1
4 Model of long-distance line 1
5 Module of 3 multimeters 1
6 Wattmeter 1
7 Mini-modules Set Electric and electronic elements 1
8 Mini-modules Set Transformers 1
9 Laboratory table with 2-section container and 1-level frame 1
10 Accessories Kit 1
11 Basic Experiments Guide Electric DC circuits 1
12 Basic Experiments Guide Electric AC circuits 1
13 Basic Experiments Guide Electronic devices 1
14 Basic Experiments Guide Long-distance line 1
15 Operating Manual 1
16 Didactic Materials CD 1

Power consumption, VA 50
Power supply:
- single-phase AC mains with working neutral and protective
wires - voltage, V
- frequency, Hz 220 22
50 0,5
Appliance class I
Total dimensions, mm (assembled) - length 910
- width height - 850
1250
Weight, kg 50

Page 50
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS 4.3.4. Parallel inductor connection.
1.Electric DC circuits. 4.3.5. Reactive power of inductor (with oscilloscope).
3.7. Parameters of electrical DC circuit. 4.4. Circuits of sinusoidal current with resistors, capacitors and inductors.
3.8. Ohms law. 4.4.1. Series resistor-capacitor connection.
3.9. Resistor circuits. 4.4.2. Parallel resistor-capacitor connection.
3.9.1. Linear resistors. 4.4.3. Series resistor-inductor connection.
3.9.2. Heat-variable resistor with negative temperature factor. 4.4.4. Parallel resistor-inductor connection.
3.9.3. Heat-variable resistor with positive temperature factor. 4.4.5. Series capacitor-inductor connection. Voltage resonance.
3.9.4. Varistor. 4.4.6. Parallel capacitor-inductor connection. Current resonance.
3.9.5. Photoresistor. 4.4.7. Frequency characteristics of series resonance circuit.
3.9.6. Series resistor connection. 4.4.8. Frequency characteristics of parallel resonance circuit.
3.9.7. Parallel resistor connection. 4.5. Transformers.
3.9.8. Series-parallel resistor connection. 4.5.1. Transformation factor.
3.9.9. Resistance voltage divider. 4.5.2. Resistance conversion by means of transformer.
3.10. Voltage (EMF) source. 4.6. Three-phase circuits of sinusoidal current.
3.11. Series connection of voltage (EMF) source. 4.6.1. Voltages and currents of three-phase circuit (with oscilloscope).
3.12. Parallel connection of voltage (EMF) source. 4.6.2. Star connection of three-phase electrical load.
3.13. Electric power and energy. 4.6.3. Delta connection of three-phase electrical load.
3.14. Electric circuit efficiency. 2.6.4. Failure modes of three-phase circuit when load connected star.
3.15. Voltage, current and power matching between voltage (EMF) source and 2.6.5. Failure modes of three-phase circuit when load connected delta.
load. 4.7. Circuits with nonsinusoidal applied voltage (with oscilloscope).
3.16. Charge and discharge of capacitor (with oscilloscope). 4.8. Transients in linear circuits (with oscilloscope).
1.11. Switching-on and switching-off circuit with inductor (with oscilloscope). 4.8.1. Transients in circuit with capacitor and resis Magnetic linkage factor.
2.Electric AC circuits. 4.8.2. tors.
4.1. Parameters of sinusoidal voltage and current(with oscilloscope). 4.8.3. Transients in circuit with inductor.
4.2. Circuits of sinusoidal current with capacitors 4.8.4. Transient in oscillating circuit.
4.2.1. Voltage and current of capacitor (with oscilloscope).
4.2.2. Imaginary impedance of capacitor(with oscilloscope). 3.Long-distance line.
4.2.3. Series capacitor connection. 5.1. Voltage distribution along homogeneous long-distance line.
4.2.4. Parallel capacitor connection. 5.2. Input resistance of long-distance transmission line as function of its
4.2.5. Reactive power of capacitor (with oscilloscope).. electrical length and load resistance.
4.3. Circuits of sinusoidal current with inductors. 5.3. Reflected waves.
4.3.1. Voltage and current of inductor (with oscilloscope)..
4.3.2. Imaginary impedance of inducitor (with oscilloscope). 4.Electronic devices.
4.3.3. Series inductor connection

Page 51
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.1. Rectifier diodes. 4.8.1. Inverting amplifier.
1.1.1. Diode characteristics. 4.8.2. Non-inverting amplifier.
1.1.2. Single-phase half-wave uncontrolled rectifier (with oscilloscope). 4.8.3. Summing amplifier.
1.1.3. Single-phase bridge-circuit uncontrolled rectifier (with oscilloscope).
4.8.4. Differential amplifier.
1.1.4. Three-phase bridge-circuit uncontrolled rectifier (with oscilloscope).
1.1.5. Three-phase zero uncontrolled rectifier(with oscilloscope). 4.8.5. Dynamics of operational amplifier (with oscilloscope).
1.2. . Stabilitron. 4.6.3. Phase control of thyristor (with oscilloscope).
4.2.1. Characteristics. 4.7. Logic elements.
4.2.2. Parametric voltage stabilizer. 4.7.1. Logic element "AND".
4.2.3. Smoothing ripples of rectified voltage(with oscilloscope). 4.7.2. Logical element "OR".
4.3. Diodes with special properties. 4.7.3. Logic element "NOT".
4.7.4. Logic element "NAND".
4.3.2. Varicap. 4.6. Thyristors.
4.4. Bipolar transistors.
4.4.1. Testing layers and study of rectifying action of bipolar transistors.
4.4.2. Distribution of current in the transistor and the control effect of the base current of the transistor.
4.4.3. Transistor characteristics.
4.4.4. Setting the operating point of the transistor, and study of effect of resistor in the collector circuit to the voltage gain of the amplifier stage with a common emitter (with
oscilloscope).r
4.4.5. Amplifiers using bipolar transistors 4.5.1. The output characteristics of transistor.
LED. Amplifiers (with oscilloscope).
(with oscilloscope). 4.6.1. Characteristics of diode thyristor.
4.4.6. Linear voltage regulator. 4.6.2. Characteristics of triode thyristor.
4.4.7. Linear current regulator. 4.7.5. Logic element "NOR".
4.6. Unipolar (field) transistors.
4.6.1. Testing layers and study of rectifying action of unipolar transistors. 4.8. Operational amplifiers.
4.6.2. Turn-on of transistor gate.
4.6.3. Control effect of n-type transistor gate.

Page 52
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
26 Theoretical fundamentals of electrical engineering 1 Set Unit Prices Total Prices
Name Pcs
Type / Model ( Rupiah ) ( Rupiah )
1 Module of voltage generators 1 TOE3-S-R Please Contact Us
2 Single-phase power supply 1 P I C T U R E
3 Testing board 1
4 Model of long-distance line 1
5 Module of 2 multimeters 1
6 Wattmeter 1
7 Mini-modules Set Electromagnetic field 1
8 Boards Set for modeling electrical and magnetic fields 1
9 Devices Set for studying skin-effect 1
10 Mini-modules Set Electromagnetic components 1
11 Laboratory table with 2-section container and 2-level frame 1
12 Accessories Kit 1
13 Basic Experiments Guide Electromagnetic field 1
14 Basic Experiments Guide Electrical and magnetic circuits 1
15 Operating Manual 1
16 Didactic materials CD 1
17 Two-channel oscilloscope 1

Page 53
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Power consumption, VA 50
Power supply: BASIC EXPERIMENTS
- single-phase AC mains with Linear DC circuits.
working neutral and protective wires 8. Measurements of resistance, current, voltage and electrical power in DC circuits.
9. Series connection of resistors.
- voltage, V 220 22
10. Parallel connection of resistors.
- frequency, Hz 50 0,5 11. Series-parallel connection of resistors.
Appliance class I 12. Power transmission from active two-pole circuit to load.
Total dimensions, mm (assembled) 8. Linear AC circuits (simple sinusoidal and nonsinusoidal current).
- length 910 1. Series connection of elements R, L and (sinusoidal current).
- width 850 2. Frequency characteristics of series resonant circuit.
- height 1600 3. Parallel connection of inductance and capacitor.
4. Frequency characteristics of parallel resonant circuit.
Weight, kg 60
5. Parameters of inductively connected coils.
Number of Workplaces 2 6. Circuits with nonsinusoidal applied voltage.
9. Three-phase circuits.
1. Star connection of three-phase electrical load.
13. Quadripoles and filters. 2. Delta connection of three-phase electrical load.
1. Parameters of passive quadripole. 3. Failure modes of three-phase circuit when load connected star.
2. Frequency characteristics of quadripole (low-pass filter). 4. Failure modes of three-phase circuit when load connected delta.
3. Simplest integral and differential quadripoles. 5. Voltage filter of negative-phase sequence.
14. Distributed-element circuits. 10. Transients in linear electrical circuits.
1. Voltage distribution along homogeneous long-distance 1. Charge and discharge of capacitor.
transmission line. 2. Switching-in and fault in circuit with inductor.
2. Input resistance of long-distance transmission line as 3. Transients in circuit with resistors and capacitor.
function of its electrical length and load resistance. 4. Switching-on and switching-off circuit with inductor.
3. Reflected waves. 5. Transients in R-L-C circuit.
15. Theory of electromagnetic field. 11. Nonlinear circuits.
1. Modelling electrostatic and magnetic fields by means of 1. Volt-ampere characteristics of nonlinear elements in DC circuit.
electrical current in conducting tape. 2. Linearized parameters of bipolar transistor.
2. Test of single-phase transformer. 3. Single-phase rectifier.
3. Measuring constant magnetic field on inductor axis by 12. Magnetic circuits.
means of Hall-effect sensor. 1. DC Magnetic circuits.
4. Magnetomotive force and magnetic potential difference. 2. AC Magnetic circuits.
5. Ferroelectrics. 3. Resonance in series circuit of nonlinear inductor and capacitor.
6. Hysteresis in ferromagnetics. s in constant magnetic field.

Page 54
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
AUTOMATION G A L S E N
No Name of Equipment Quantity
1 Automation of Technological Processes and 1 Set Unit Prices Total Prices
Industries Based on Mitsubishi Devices Type / Model ( Rupiah ) ( Rupiah )
Basic Experiments Modules / Components: ATPP2-N-K Please Contact Us
Studying basic features of the Single-phase Power Supply P I C T U R E
Mitsubishi Light Signaling Module
controller and operator's panel Control Post
(Programming the controller; Programming Buzzer
the operator's panel using GT Designer 3 Executive Motor
software; Programming timers and Model of Heated Room
counters) Controller Unit and Operator Panel
Using the Mitsubishi controller and Optical Switches Module
operator's panel in applications Light Sensor
(Automatic control system of traffic lights; Desktop Containter with 1-Level Frame
Automatic control system of interior Accessories Kit
lighting; Automatic control of outdoor Basic Experiments Guide
lighting; Automatic control system sounder; Notebook with Software
Automatic backup power turn on;
Automatic alarm system; Automatic control
system of executive motor; Automatic
indoor air temperature
control system)

Page 55
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 Smart Relay 1 Set Unit Prices Total Prices
Basic Experiments
Type / Model ( Rupiah ) ( Rupiah )
Programmable relay LOGO! control IR1-P-R Please Contact Us
Testing basic logic functions P I C T U R E
Testing specific logic functions
Creating and testing circuit program
Traffic light automatic control

Modules / Components:
Portable Smart Relay Module
Accessories Kit
Basic Experiments Guide

Page 56
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
3 Sensors of Technological Parameters 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Basic Experiments:
Static characteristics of current and voltage sensors (5 types) Static characteristics of DTP1-N-R Please Contact Us
tachometergenerator and optical encoder Static and dynamic characteristics of P I C T U R E
temperature sensors (5 types) Static characteristics of linear position sensors (6
types) Static characteristics of proximity sensor-switches (3 types) Static
characteristics of angle position sensors (3 types) Static characteristic of pressure
sensor

Modules / Components:
Power Supply
Single-phase Power Supply
Electric Heater
Linear Position Sensor Module
Angle Position Sensor Module
Pressure Sensor Module
Current And Voltage Sensors Module
Speed Sensor Module
Impulse Counter Sensor Module
Module Of Two Multimeters
Temperature Sensors Kit
Linear Position Sensors Kit
Desktop Container With 2-level Frame
Accessories Kit
Basic Experiments Guide

Page 57
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
4 Automation based on Programmable Controller 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Basic Experiments:
Programmable controller (Control of programmable controller; Test of basic logic APK1-N-R Please Contact Us
functions; Test of special logic functions; Creation and test of commutation program) P I C T U R E
Control systems based on programmable
controller (Traffic light control system; Indoor lighting control system; Outdoor lighting
control system; Sounder control system; Automatic switching-on of elec-tric power reserve;
Three-pole switching; Automatic alarm system; Control system of executive motor; Pulse
control of room air temperature room; Continuous control of room air temperature by
proportionalplus-integral regulator; DC motor twostage startup control as function of time;
DC motor dynamic brake control as function of speed; DC motor speed control by
proportional-plus-integral regulator)

Modules / Components:
Single-phase Power Supply
Light Signaling Module
Button Control Module
Buzzer
Executive Electric Motor
Model Of Heated Space
Programmable Controller Module
Dc Converter
Electric DC Drive
Optical Switches Module
Light Sensor
Desktop Container With 1-level Frame
Accessories Kit
Basic Experiments Guide

Page 58
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
5 Automation based on Programmable Relay 1 Set Unit Prices Total Prices
Power consumption, VA 50
Type / Model ( Rupiah ) ( Rupiah )
Power supply: APR1-S-K Please Contact Us
- single-phase AC mains with P I C T U R E
working neutral and protective wires
- voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 500
- height 400
Weight, kg 10

Page 59
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Name Pcs
BASIC EXPERIMENTS:
1 Single-phase power supply 1
1. Programmable relay.
2 Module of light signaling 1 1. Control of programmable relay.
3 Module of programmable relay 1 2. Programming relay with computer aid.
4 Module of button control 1 3. Test of basic logic functions.
5 Buzzer 1 4. Test of special logic functions.
6 Executive electric motor 1 5. Creation and test of commutation program.
7 Model of heated space 1 2. Control systems based on programmable relay.
1. Traffic light control system.
8 Module of optical switches 1
2. Indoor lighting control system.
9 Light sensor 3. Outdoor lighting control system.
10 Laboratory table 1 4. Sounder control system.
11 Laboratory table with 2-section container and 1-level frame 5. Automatic switching-on of electric power reserve.
12 Accessories Kit 1 6. Automatic alarm system.
13 Basic Experiments Guide Automation based on programmable relay 7. Control system of executive motor.
8. Temperature control system of air in the room.
14 Basic Experiments Guide Automation based on programmable relay 1
15 Operating Manual 1
16 Didactic materials CD 1
17 Notebook 1

Page 60
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
6 Fundamentals of automation in industry 1 Set Unit Prices Total Prices
Module / Component Pcs Type / Model ( Rupiah ) ( Rupiah )
1 Single-phase Power Supply 1 OAP1-S-R Please Contact Us
2 Module for Testing Digital Devices 1 P I C T U R E
3 Light Signaling Module 1
4 Programmable Relay Module 1
5 Button Control Module 1
6 Executive Electric Motor 1
7 Heated Space Model 1
8 Electric Heater 1
9 Linear Position Sensors Testing Module 1
10 Pressure Sensor Testing Module 1
11 Multimeters Module (2 Multimeters) 1
12 Mini-modules Set Production Automation Fundamentals 1
13 Temperature Sensors Kit 1
14 Linear Position Sensors Kit 1
15 Laboratory Table with 2-section Storage Container and 2-level Frame 1
16 Accessories Kit 1
17 Basic Experiments Guide 1
18 Operation Manual 1
19 Didactic Materials CD 1

Page 61
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Power consumption, VA 250 BASIC EXPERIMENTS
Electric supply:
- single-phase AC circuit with
2. Sensors of technological parameters.
working neutral and protective leads
1.1. -.
voltage, V 220 22
1.2. Analog position sensors.
- frequency, Hz 50 0,5
1.3. Pressure sensor.
Appliance class I
1.4. Temperature sensors.
Total dimensions, mm (assembled)
2. Digital devices.
- length 910
2.1. Logic elements.
- width 850
2.2. Triggers.
- height 1600
2.3. Registers.
Weight, Kg 60
2.4. Impulse counters.
3. Analog and analog-digital devices.
3.1. Operational amplifier.
3.2. Commutators.
3.3. Digital-to-analog converter.
3.4. Analog-to-digital converter.
4. Control devices.
4.1. Command apparatus with rigid logic.
4.2. Programmable relay.
4.3. Command apparatus on base of programmable relay.
4.4. Command apparatus for traffic lights control.
5. Automatic systems.
5.1. Automatic temperature control.
5.2. Executive electric motor automatic control.
5.3. System of automatic temperature regulation.

Page 62
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
7 Programmable Relay 1 Set Unit Prices Total Prices
Power consumption, VA 50 Type / Model ( Rupiah ) ( Rupiah )
Power supply: PR1-N-R Please Contact Us
- single-phase AC mains with P I C T U R E
working neutral and protective
wires 220 22
- voltage, V 50 0,5
- frequency, Hz
Appliance class I
Total dimensions, mm (assembled)
- length 530
- width 500
- height 400
Weight, kg 5
Components list
Name Pcs
1 Single-phase power supply 1
2 Module of light signaling 1
3 Module of programmable Siemens LOGO relay 1
4 Module of button control 1
5 Desktop container with 1-level frame (length 530 mm) 1
6 Accessories Kit 1
7 Basic Experiments Guide Automation based on programmable relay 1
8 Operating Manual 1
9 Didactic materials CD 1
BASIC EXPERIMENTS
3. Control of programmable relay.
1. Test of basic logic functions.
2. Test of special logic functions. Creation and test of commutation program

Page 63
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
8 Means of automation & control 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
2.1. Power consumption, VA 50
2.2. Electric supply: SAU1-S-K Please Contact Us
- single-phase AC P I C T U R E
circuit with
working neutral and 220 22
protective leads 50 0,5
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 2910
- length 850
- width 1600
- height
2.5. Weight, Kg 80

Page 64
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS Module / Component Pcs
1 Single-phase Power Supply 1
4. Programmable controller. 2 Light Signaling Module 1
1. Control of programmable controller. 3 Button Control Module 1
2. Programming controller with computer aid. 4 Buzzer 1
3. Test of basic logic functions.
5 Executive Electric Motor 1
4. Test of special logic functions.
5. Test of commutation program. 6 Heated Space Model 1
5. Control systems based on programmable controller. 7 Programmable Controller Module 1
1. Traffic light control system. 8 DC-to-DC Inverter 1
2. Indoor lighting control system. 9 DC Electric Drive 1
3. Outdoor lighting control system. 10 Electric Heater 1
4. Sounder control system. 11 Linear Position Sensors Testing Module 1
5. Automatic switching-on of back-up electric power supply.
12 Angular Position Sensor Test Unit 1
6. Automatic alarm system.
7. Control system of executive motor. 13 Optical Switch Module 1
8. Temperature control pulse system of air in the room. 14 Light Sensor 1
9. Temperature control stepless system of air in the room with PI-regulator. 15 Pulse Counter Module 1
10. Automatic double-stage DC motor start as function of time. 16 Multimeters Module (2 Multimeters) 1
11. Automatic double-stage DC motor start as function of speed. 17 Temperature Sensors Kit 1
12. Automatic DC motor start with PI-regulator. . 18 Linear Position Sensors Kit 1
6. Tests of standard units of control panels and sensors of technological
parameters. 19 Laboratory Table 1
1. Test of linear position sensor. 20 Laboratory Table with 2-section Storage Container and 2-level Frame 1
2. Test of angular position sensor and universal counter. 21 Accessories Kit 1
3. Test of temperature sensors and unit of temperature measurement regulation. 22 Basic Experiments Guide 1
23 Operation Manual 1
24 Didactic and Software CD 1
25 Notebook 1

Page 65
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
ELECTROMECHANICS G A L S E N
No Name of Equipment Quantity
1 Electric Apparatus 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Modules / Components: EA1-S-R Please Contact Us
Operation apparatus (Electromagnetic Induction motor; Three-phase power
supply; P I C T U R E
contactor returning ratio. Time-current
characteristic of thermal electric relay. AC Single-phase power supply; Active
electromagnetic relay returning ratio. AC load; Adjustable autotransformer;
voltage electromagnetic auxiliaryrelay Rectifier; Rheostat; Module of button
returning ratio. Time lag as function of relay control;
pull-in value. Magnetic starter in induction Module of light signaling; Thermal
motor nonreversible speed control. Magnetic electric relay; Automatic single-pole
starter in induction motor reversible speed breaker; Automatic three-pole breaker
control. Programming and operating of Contactor; Current-overload relay;
microprocessor module of induction motor Module
control and current of induction motor current protection;
protection) Apparatus of switchgears (Time- Time relay; Auxiliary relay; Single-phase
current characteristic of fuse. Time-current transformer; Doubled electric reactor
characteristic of automatic air circuit-breaker. Module of fuses and overvoltage limiters;
Time-current characteristic of overvoltage Current transformer; Voltage transformer;
limiter. Inductance of doubled electric reactor. Module of three multimeters; Current and
Current transformer measurement error. time meter; Laboratory table with 2-level
Voltage transformer measurement error) frame; Laboratory table with 2-section
storage
and 2-level frame; Accessories Kit;
Basic Experiments Guide

Page 66
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 Electric 1 Set Unit Prices Total Prices
Machines Type / Model ( Rupiah ) ( Rupiah )
EM1M-S-R Please Contact Us
P I C T U R E
Modules / Components:
Electromechanical unit (DC machine, AC
motor and angular displacement transducer);
Three-phase power supply; DC
motor power supply; Synchronous
machine exciter; Frequency converter;
Single-phase power supply; Three-pole
breaker; Active load; Rheostat for AC
machine rotor; Excitation rheostat of DC
machine; Line reactor; Capacitive load;
Module of synchronizing; Rheostat
Inductive load; Three-phase transformer
group; Adjustable three-phase
autotransformer; Voltage and frequency
meter; Synchronous machine torque angle
meter; Speed indicator; Module of 3 multimeters;
Voltmeter; Multifunctional electrical
measuring instrument; Laboratory
table with 2-level frame; Laboratory table
with 2-section storage and 2-level frame;
Accessories kit; Basic Experiments Guide

Page 67
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Single-phase transformer (Transformation ratio of single-phase transformer. Idling
characteristics. Short-circuit characteristics.Characteristic U = f (I) of single-phase
transformer with resistive load. Operational characteristics of single-phase transformer
with a resistive load. Determination of equalizing current caused by inequality o f
transformation ratios of parallel singlephase transformers. Effect caused by the
inequality of short-circuit voltages of singlephase transformers operating in parallel)
Single-phase autotransformer (Transformation ratio of single-phase autotransformer.
Short-circuit characteristics. Characteristic U = f (I) of single-phase during resistive
load) Three-phase transformer (Idling characteristics.Short-circuit characteristics.
Checking vector grouping of three-phase transformer. Confirmation of impossibility of
parallel operation of three-phase transformers with different vector grouping)
DC generators with separate / shunt excitation
(Idling characteristics of DC generator with separate excitation. Short-circuit
characteristics of DC generator with separate excitation. Characteristics U = f (I), If = f
(I)
and U = f (I ) of DC generator with separate f excitation. Characteristic U = f (I) of DC
generator with shunt excitation)
DC motors with separate/ parallel / series
excitation (Electromechanical (speed) characteristics. Mechanical characteristics.
Operational characteristics. Speed control of DC motor by armature voltage changing.
Speed control of a DC motor by changing additional resistance in the armature circuit.
Speed control of a DC motor by field current change. Speed control motor with series
excitation by shunting field winding)
Three-phase squirrel-cage induction motor
(Idling characteristics. Short-circuit characteristics. Electromechanical (speed)
characteristic. Mechanical characteristic. Operational characteristics. Speed control
of three-phase squirrel-cage induction motor by stator voltage changing) Three-phase
wound-rotor induction motor
(Electromechanical (speed) characteristic.Mechanical characteristic. Operational
characteristics.Speed control of three-phase wound-rotor induction motor by active
rotor resistance changing)
Three-phase synchronous generator (Idling characteristic. Short-circuit
characteristic.

Page 68
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
3 Electric 1 Set Unit Prices Total Prices
Drives Type / Model ( Rupiah ) ( Rupiah )
EP1M-S-K Please Contact Us
P I C T U R E

Modules / Components:
Electromechanical unit with flywheel (DC
machine, AC motor and angular displacement
transducer); Three-phase power supply;
Synchronous machine exciter; Singlephase
thyristor converter; Frequency converter;
Single-phase power supply; Threepole
breaker; Terminal; Active load;
Rheostat for AC machine rotor; Excitation
rheostat of DC machine; Rectifier;
Rheostat; Connector; Module of digital signals
input/output; Three-phase transformer
group; Module of regulators;
Module of current-and-voltage sensors;
Synchronous machine torque angle meter
Speed indicator; Module of two multimeters;
Voltammeter; Multifunctional electrical
measuring instrument; Laboratory
table with 2-section storage and 2-level
frame; Laboratory table with computer
rack and pullout keyboard shelf and 2-
level frame; Laboratory table with storage
container for wires and 2-level frame;
Accessories Kit; Basic Experiments Guide
Personal computer

P I C T U R E
Page 69
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Basic Experiments: modes. Speed control by match changing frequency and magnitude of stator voltage. Stator current
Mechanics of drives(Determination of inertia moment of electric drive and speed as function of time during transient. Definition of energy parameters of electric drive with
by method of free run-out. Determination of mechanical characteristic of induction motor. Measurement of body temperature of induction motor)
working mechanism. Drive speed as function of time during transient) Electric drive using synchronous motor
Electric drive using DC motor with separate (Electromechanical and mechanical characteristics of electric drive with synchronous motor. Static
(parallel, series) excitation (Determination of electromechanical and angle characteristic. Static Vcurve characteristic. Reactive power control by changing excitation
mechanical characteristics of electric drive in motor, generator, and current. Stator current and speed as function of time during transient. Definition of energy parameters
braking modes. Speed control by changing resistance in armature circuit of electric drive with synchronous motor. Measurement of body temperature of synchronous motor)
of DC motor. Speed control by changing excitation current of DC motor. Open-loop control of electric drives (DC drive startup control in function of time (speed, EMF,
Speed control by shunting field winding of DC motor with series armature current) and dynamic braking in function of time (speed, EMF). Induction squirrel-cage
excitation. Speed control by changing armature voltage DC motor. motor control during direct-on-line startup, reverse and dynamic braking in function of time (plugging).
Armature current and speed as function of time during transient. Induction wound-rotor motor control during direct-on-line startup in function of time (speed, EMF,
Definition of energy parameters of electric drive with DC motor. stator current), reverse and dynamic braking in function of time (speed, EMF). Synchronous motor
Measuring body temperature of DC motor) control of startup and braking)
Electric drive using squirrel-cage induction Closed-loop control of electric drives (Thyristor converter - DC motor. Control characteristics.
motor (Electromechanical and mechanical characteristics of electric Current control contour adjustment. Limiter adjustment. Speed contro
drive with induction motor in motor, generator, and braking modes.
Speed control by match changing frequency and magnitude of stator
voltage. Stator current and speed as function of time during transient.
Definition of energy parameters of electric drive with induction motor.
Measurement of body temperature of induction motor)
Electric drive using wound-rotor induction
motor (Electromechanical and mechanical characteristics of electric
drive with induction motor in motor, generator, and braking

Page 70
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
4 Electric Machines and 1 Set Unit Prices Total Prices
Drives Type / Model ( Rupiah ) ( Rupiah )
EMP1M-S-K Please Contact Us
P I C T U R E
Modules / Components:
Electromechanical unit with flywheel (DC machine,
induction motor and angular displacement transducer);
Three-phase power supply; Single-phase thyristor
converter; Frequency converter; Single-phase
power supply; Three-pole breaker; Terminal; Active
load; Excitation rheostat of DC machine; Linear
reactor;
Adjustable autotransformer; Rectifier;
Rheostat; Connector; Module of digital signals
input/output; Three-phase transformer group;
Adjustable three-phase autotransformer; Module of
regulators; Module of current-and-voltage sensors;
Speed indicator; Module of two multimeters;
Voltammeter; Multifunctional electrical measuring
instrument; Laboratory table with 2-section storage
container and 2-level frame; Laboratory table with
computer rack and pullout keyboard shelf and 2-
level frame; Laboratory table with storage container
for wires and 2-level frame; Accessories Kit; Basic
Experiments Guide; Personal computer

Page 71
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Basic Experiments:
Single-phase transformer (Transformation Speed control by field current change. Speed control motor with series excitation by shunting field winding. DC motor
ratio of single-phase transformer. Idling characteristics. startup)
Short-circuit characteristics. Three-phase induction generator (Power characteristics. Ideal idling characteristics Operational characteristics)
Characteristic U = f (I) single-phase transformer Three-phase squirrel-cage induction motor
with resistive load. Operational characteristics (Idling characteristics. Short-circuit characteristics. Electromechanical (speed) characteristic. Mechanical characteristic.
of single-phase transformer with a Operational characteristics. Speed control of three-phase squirrel-cage induction motor by stator voltage changing.
resistive load. Determination of equalizing current Induction motor startup)
caused by inequality of transformation Mechanics of drives (Determination of inertia moment of electric drive by method of free run-out. Determination of
ratios of parallel single-phase transformers. mechanical characteristic of working mechanism. Drive speed as function of time during transient)
Effect caused by the inequality of short-circuit Electric drive using DC motor with separate
voltages of single-phase transformers operating (parallel, series) excitation (Determination of electromechanical and mechanical characteristics in motor, generator,
in parallel) and braking modes. Speed control by changing resistance in armature circuit of DC motor. Speed control by changing
Single-phase autotransformer (Transformation excitation current of DC motor. Speed control by shunting field winding of DC motor with series excitation. Speed control
ratio. Short-circuit characteristics. by changing armature voltage DC motor. Armature current and speed as function of time during transient. Definition of
Characteristic U = f (I) under resistive load) energyparameters of electric drive with DC motor.Measuring body temperature of DC motor)
Three-phase transformer (Idling characteristics. Electric drive using squirrel-cage induction
Short-circuit characteristics. Checking motor (Electromechanical and mechanical characteristics in motor, generator, and braking modes. Speed control by
vector grouping of three-phase transformer. match changing frequency and magnitude of stator voltage. Stator current and speed as function of time during transient.
Confirmation of impossibility of parallel operation Definition of energy parameters of electric drive with induction motor. Measurement of body temperature of induction
of three-phase transformers with different motor)
vector grouping) Open-loop control of electric drives (DC drive startup control in function of time (speed, EMF armature current) and
DC generators with separate / shunt excitation dynamic braking in function of time (speed, EMF). Induction squirrelcage motor control during direct-on-line startup,
(Idling of DC generator with separate excitation. reverse and dynamic braking in function of time (plugging). Induction wound-rotor motor control during direct-on-line
Short-circuit characteristics of DC generator startup in function of time (speed, EMF, stator current), reverse and dynamic braking in function of time (speed, EMF).
with separate excitation. Characteristics U Synchronous motor control of startup and
= f (I), If = f (I) and U = f (I ) of DC generator f braking)
with separate excitation. Characteristic U=f(I) Closed-loop control of electric drives (Thyristor converter - DC motor. Control characteristics. Current control contour
of DC generator with shunt excitation) adjustment. Limiter adjustment. Speed control contour adjustment. Determination of static electromechanical and
DC motors with separate / parallel / series excitation mechanical characteristics. Frequency converter - induction motor. Speed control contour adjustment. Determination of
(Electromechanical (speed) characteristics. static electromechanical and mechanical characteristics)
Mechanical characteristics. Operational
characteristics. Speed control by armature voltage
changing. Speed control by changing additional
resistance in the armature circuit

Page 72
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
5 Frequency Converter - Induction Motor 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Study of Frequency converter induction motor static and dynamic modes during PCHAD1-S-K Please Contact Us
manual control Study of Frequency converter induction motor static and dynamic P I C T U R E
modes during computer control.

Modules / Components:
Electromechanical Unit With Flywheel (DC
Machine, Induction Motor And Angular
Displacement Transducer); DC Voltage
Supply; Frequency Converter; Single-phase
Power Supply; Terminal; Connector;
Module Of Current-and-voltage Sensors;
Speed Indicator; Laboratory Table With 2-
section Storage Container And 2-level
Frame; Laboratory Table With Computer
Rack And Pullout Keyboard Shelf;
Accessories Kit; Basic Experiments Guide;
Data Acquisition Board; Personal
Computer With Software

Page 73
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
6 Single-phase Capacity Motor 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Idling characteristics of single-phase capacity motor Short-circuit characteristics single- KOD1-N-R Please Contact Us
phase capacity motor Electromechanical characteristic n=f(I) Mechanical characteristic P I C T U R E
n=f(M) Operating characteristics I=f(P ), P =f(P ), 2 1 2 s=f(P ), =f(P ), cos=f(P ), M=f(P )
2 2 2 2 Maximum motor torque as function of capacitor size

Modules / Components:
Electromechanical Unit (Single-phase
Capacity Motor, Induction Motor and
Angular Displacement Transducer); Singlephase
Power Supply; Adjustable Autotransformer;
Rectifier; Speed Indicator;
Power Meter; Module Of Three Multimeters;
Laboratory Table With 2-section
Storage Container and 2-level Frame;
Accessories Kit; Basic Experiments Guide

Page 74
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
7 Slip Ring Induction Motor 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Characteristics (Finding no-load characteristics I =f(U), =f(U), cos =f(U). 0 0 0 Finding ADFR1-N-R Please Contact Us
short circuit characteristics I =f(U), =f(U), cos =f(U). Finding SC SC SC mechanical P I C T U R E
characteristic n=f(M). Finding operational characteristics I=f(P ), P =f(P ), s=f(P ), =f(P ), 2
1 2 2 2 cos=f(P ), M=f(P ) Speed control (Speed control by changing stator voltage.
Speed control by changing active resistance of rotor circuit)

Modules / Components:
Electromechanical Unit (DC Machine, AC
Motor and Angle-to-digit Converter); Threephase
Power Supply; Single-phase Power
Supply; Active Load; AC Machine Rotor
Rheostat; Line Reactor; Adjustable
Autotransformer; Rectifier; Three-phase
Transformer Group; Speed Indicator;
Wattmeter; Three Multimeters Module;
Desktop Container With Double-level
Frame; Desktop Container With Singlelevel
Frame; Accessories Kit; Basic
Experiments Guide

Page 75
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
8 Three-phase Synchronous Generator 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Connection in parallel power network (Ideal synchronizing. Coarse synchronizing) TSG1-N-R Please Contact Us
Characteristics (Finding no-load characteristic E =f(I ). Finding short-circuit char- P I C T U R E
acteristic I =f(I ). Finding output U=f(I), SC f regulation If= f(I) and load U=f(I ) charac- f
teristics. Finding angle characteristics P=f(), Q=f(), U=f().Finding U-curve characteristic
I=f(I ).

Modules / Components:
Electromechanical Unit (DC Machine, AC
Machine and Angular Displacement
Transducer); Three-phase Power Supply;
DC Machine Power Supply; Synchronous
Machine Exciter; Single-phase Power
Supply; Three-pole Switch; Active Load;
Line Reactor; Capacitive Load;
Sychronizing Module; Inductive Load;
Three-phase Transformer Group; Voltage
and Frequency Meter; Synchronous
Machine Torque Angle Indicator; Speed
Indicator; Wattmeter; Three Multimeters
Module; Desktop Containers With Twolevel
Frame; Accessories Kit; Basic
Experiments Guide

Page 76
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
9 Three-phase Induction Motor With Fault Imitator 1 Set Unit Prices Total Prices
Basic Experiments:
Type / Model ( Rupiah ) ( Rupiah )
TADIN1-N-R Please Contact Us
Modeling and revealing isolation damage (between induction motor stator phase U and P I C T U R E
body, V and body, W and body) Modeling and revealing isolation damage (between
induction motor stator phases U and V, U and W, V and W) Modeling and revealing loss
of induction motor stator phases U, V, W Modeling and revealing turn-to-turn faults in
induction motor stator phases U, V, W

Modules / Components:

Induction Motor
Fault Imitator
Multimeter
Operation Manual

Page 77
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
10 Mitsubishi Servodrive 1 Set Unit Prices Total Prices
Basic Experiments:
Type / Model ( Rupiah ) ( Rupiah )
Adjustment of Servoamplifier Mitsubishi SPM1-N-K Please Contact Us
settings (Configure settings manually; Configure settings using computer program MR P I C T U R E
Configurator)
Speed control of Mitsubishi Servodrive
(Manual speed control; Management of start-up and braking; Speed control using a
computer program MR Configurator)
Position control of Mitsubishi Servodrive
(Manual position control in relative units; Manual position control n absolute units;
Configure settings of electronic gearing; Position control using computer program
MR Configurator)

Modules / Components:
Single-phase Power Supply
Servoamplifier with Mitsubishi Servomotor
Two Multimeters Unit
Desktop Containter with 1-Level Frame
Accessories Kit
Basic Experiments Guide
USB oscilloscope
Notebook
Software

Page 78
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
11 Electric apparatus 1 Set Unit Prices Total Prices
Power consumption, VA 200 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
-three-phase AC circuit with EA2-S-R Please Contact Us
working neutral and protective leads P I C T U R E
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 2x910
- width 850
- height 1600
Weight, Kg 180

BASIC EXPERIMENTS

1. Physical phenomena in electric apparatus


1.1. Solenoid coil heating and cooling at short-time and intermittent modes of operation.
1.2.Dependence between transient contact resistance and compression force.
1.3.Voltage curves on contacts when switching-off active, inductive and capacitive loads.
1.4.Electromagnet traction characteristic.
2. Operation apparatus
2.1.Electromagnetic contactor returning ratio.
2.2.Time-current characteristic of thermal electric relay.
2.3.AC electromagnetic relay returning ratio.
2.4. Auxiliary electromagnetic relay returning ratio.
1. 2.5. Dependence of time delay from time relay pull-in value.
2.6. Magnetic starter operation in non-reversing induction motor control circuit.
2.7. Magnetic starter operation in reversing induction motor control circuit.
2.8. Programming and operation of microprocessor control unit as well as overcurrent
protection of induction motor.

Page 79
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs 27 Module of 3 multimeters 1
1 Induction motor (106) 1 28 Current and time meter 1
2 Three-phase power supply 1 29 Minimodule set Electric apparatus 1
3 Single-phase power supply 1 30 Minimodule set Fundamentals of digit technology 1
4 Module of testing digital devices 1 31 Laboratory table with 2-section storage and 2-level frame 2
5 Power supply with testing board 1 32 Accessories Kit 1
6 Active load 1 33 Basic Experiments Guide Electric apparatus 1
7 Adjustable autotransformer 1 34 Basic Experiments Guide Fundamentals of digit technology 1
8 Rectifier 1 35 Operation Manual 1
9 Rheostat 1 36 Didactic materials CD 1
10 Module of button control 1 37 2-channel oscilloscope 1
11 Module of light signaling 1 . Study of operational amplifier with positive feedback in relay mode (Schmitt trigger).
12 Thermal electric relay 1 2.10. Modeling functional converters based on operational amplifier.
13 Automatic single-pole breaker 1 2.11. Testing basic logic elements and simple combinational logic elements based on them.
14 Automatic three-pole breaker 1 2.12. Testing typical combinational logic elements.
15 Contactor 2 2.13. Testing triggers.
16 Current-overload relay 1 2.14. Testing registers.
17 Module of induction motor current protection 1 2.15. Testing counters.
18 Time relay 1 2.16. Characteristics of optron relay.
19 Auxiliary relay 1 2.17. Characteristic "input-output" and sensitivity of strength sensor.
20 Single-phase transformer 1 2.18. Tripping zone of inductive, capacitive and optical proximity switches.
21 Doubled electric reactor 1 1. Apparatus of switchgears
22 Module of fuses and overvoltage limiters 1 3.1.Time-current characteristic of fuse.
23 Module of testing contactless (?) breakers 1 3.2.Time-current characteristic of automatic air circuit-breaker.
24 Module of testing electric apparatus 1 3.3.Time-current characteristic of overvoltage limiter.
25 Current transformer 1 3.4.Inductance of doubled electric reactor.
26 Voltage transformer 1 3.5.Current transformer measurement error.
3.6.Voltage transformer measurement error.

Page 80
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
12 Electric apparatus 1 Set Unit Prices Total Prices
Power consumption, VA 200 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
-three-phase AC circuit with EA3-S-R Please Contact Us
working neutral and protective leads P I C T U R E
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1600
Weight, Kg 80

BASIC EXPERIMENTS

1. Operation apparatus
1.1. Electromagnetic contactor returning ratio.
1.2. Time-current characteristic of thermal electric relay.
1.3. AC electromagnetic relay returning ratio.
1.4. AC voltage electromagnetic auxiliary relay returning ratio.
1.5. Time lag as function of relay pull-in value.

1. Apparatus of switchgears
1.1. Time-current characteristic of fuse.
1.2. Time-current characteristic of automatic air circuit-breaker.
1.3. Time-current characteristic of overvoltage limiter.
1.4. Inductance of doubled electric reactor.
1.5. Current transformer measurement error.
1.6. Voltage transformer measurement error.

Page 81
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Single-phase power supply 1
2 Active load 1
3 Adjustable autotransformer 1
4 Rheostat 1
5 Thermal electric relay 1
6 Automatic single-pole breaker 1
7 Contactor 2
8 Current-overload relay 1
9 Time relay 1
10 Auxiliary relay 1
11 Single-phase transformer 1
12 Doubled electric reactor 1
13 Module of fuses and overvoltage limiters 1
14 Current transformer 1
15 Voltage transformer 1
16 Module of 3 multimeters 1
17 Current and time meter 1
18 Laboratory table with 2-section storage and 2-level frame 1
19 Accessories Kit 1
20 Basic Experiments Guide Electric apparatus 1
21 Operation Manual 1
22 Didactic materials CD 1

Page 82
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
13 Electric apparatus 1 Set Unit Prices Total Prices
Power consumption, VA 200 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
- single-phase AC circuit with EA4-S-R Please Contact Us
working neutral and protective P I C T U R E
leads 220 22
- voltage, V 50 0,5
- frequency, Hertz
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1600
Weight, Kg 80

BASIC EXPERIMENTS

1. Operation apparatus
1. Electromagnetic contactor returning ratio.
2. Time-current characteristic of thermal electric relay.
3. AC electromagnetic relay returning ratio.
4. AC voltage electromagnetic auxiliary relay returning ratio.
5. Time lag as function of relay pull-in value.
6. Magnetic starter operation.
7. Detecting operation zone of induction, capacitive and optical non-contact breakers.
2. Apparatus of switchgears
1. Time-current characteristic of fuse.
2. Time-current characteristic of automatic air circuit-breaker.
Time-current characteristic of overvoltage limiter

Page 83
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Single-phase power supply 1
2 Module of power supply 1
3 Adjustable autotransformer 1
4 Rectifier 1
5 Module of button control 1
6 Module of light signaling 1
7 Thermal electric relay 1
8 Automatic single-pole breaker 1
9 Contactor 2
10 Current-overload relay 1
11 Time relay 1
12 Auxiliary relay 1
13 Single-phase transformer 1
14 Doubled electric reactor 1
15 Module of fuses and overvoltage limiters 1
16 Module of testing non-contact breakers 1
17 Module of 2 multimeters 1
18 Current and time meter 1
19 Laboratory table with 2-section storage and 2-level frame 1
20 Accessories Kit 1
21 Basic Experiments Guide Electric apparatus 1
22 Operation Manual 1
23 Didactic materials CD 1

Page 84
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
14 Electric machines 1 Set Unit Prices Total Prices
Power consumption, VA 500 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
-three-phase AC circuit with EM2M-S-K Please Contact Us
working neutral and protective leads P I C T U R E
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 2x910
- width 850
- height 1600
Weight, Kg 180
BASIC EXPERIMENTS

1. Single-phase transformer.
1.1. Transformation ratio of single-phase transformer.
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase transformer.
1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) single-phase transformer.
1.4. Characteristic U = f (I) single-phase transformer with resistive load.
1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of single-
phase transformer with a resistive load.
1.6. Computer registration of singlephase transformer switching-on current.
2. DC generators with separate / shunt excitation.
2.1. Idling characteristics E0 = f (If) of DC generator with separate excitation.
2.2. Short-circuit characteristics IK = f (If) of DC generator with separate excitation.
2.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with separate excitation.
2.4. Characteristic U = f (I) of DC generator with shunt excitation.
2.5. Computer registration of DC shunt generator self excitation.
2.6. Computer registration of DC shunt generator short circuit.

Page 85
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
. DC mot DC motors with separate/ shunt / series excitation
3.1. Electromechanical (speed) characteristics n = f (I) of DC motor with separate / parallel / series Module / Component Pcs
excitation. 1 Electromechanical unit (DC machine 101.2 , AC motor 106 1
3.2. Mechanical characteristics of n = f (M) of DC motor with an separate / parallel / series excitation. and angular displacement transducer)
3.3. Operational characteristics n = f (P2), P1 = f (P2), M = f (P2), = f (P2) of DC motor with separate 2 Three-phase power supply 1
/ parallel / series excitation. 3 DC motor power supply 1
3.4. Speed control of DC motor with separate / parallel / series excitation by armature voltage changing. 4 Frequency converter 1
3.5. Speed control of a DC motor with separate / parallel / series excitation by changing additional
5 Single-phase power supply 1
resistance in the armature circuit.
3.6. Speed control of a DC motor with separate / shunt excitation by field current change. 6 Three-pole switch 1
3.7. Speed control motor with series excitation by shunting field winding. 7 Active load 1
3.8. Computer registration of start of DC motors with separate / parallel / series excitation. 8 Excitation rheostat of DC machine 1
4. Three-phase induction generator. 9 Line reactor 1
4.1. Ideal idling characteristics I0=f(U), Q0=f(U). 10 Rectifier 1
4.2. Energy characteristics =f(n), Q=f(n).
11 Rheostat 1
4.3. Operational characteristics n=f(), I=f(), Q=f(), cos=f(P).
12 Connector 1
5. Three-phase squirrel-cage induction motor. 13 Single-phase transformer 1
5.1. Idling characteristics I0 = f (U), P0 = f (U), cos0 = f (U) . 14 Three-phase adjustable transformer 1
5.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) . 15 Module of current and voltage sensors 1
5.3. Electromechanical (speed) characteristic n = f (I). 16 Speed indicator 1
5.4. Mechanical characteristic n = f (M). 17 Module of 3 multimeters 1
5.5. Operational characteristics I = f (P2), P1 = f (P2), s = f (P2), = f (P2), cos = f (P2), M = f (P2).
18 Voltmeter 1
5.6. Speed control of three-phase squirrel-cage induction motor by stator voltage changing.
5.7. Speed control of three-phase squirrel-cage induction motor by match stator voltage and frequency 19 Single-phase parameters meter 1
changing. 20 Laboratory table with 2-section storage container and 2-level 1
5.8. Computer registration of induction motor direct start. frame
21 Laboratory table with computer rack and pullout keyboard 1
shelf and 2-level frame
22 Set of accessories 1
23 Basic Experiments Guide Electric machines 1
24 Operation manual 1
25 Didactic materials and Software CD 1
26 Personal computer 1

Page 86
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
15 Electric machines 1 Set Unit Prices Total Prices
Power consumption, VA 200 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
EM2M-S-R Please Contact Us
- single-phase AC circuit with P I C T U R E
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1900
Weight, Kg 100

BASIC EXPERIMENTS

1. Single-phase transformer.
1.1. Transformation ratio of single-phase transformer.
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase transformer.
1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) single-phase transformer.
1.4. Characteristic U = f (I) single-phase transformer with resistive load.
1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of single-
phase transformer at a resistive load.
2. DC generators with separate / shunt excitation.
2.1. Idling characteristic E0 = f (If) of DC generator with separate excitation.
2.2. Short-circuit characteristic IK = f (If) of DC generator with separate excitation.
2.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with separate excitation.
2.4. Characteristic U = f (I) of DC generator with shunt excitation.
. DC motors with separate/ shunt/ series excitation.
3.1. Electromechanical (speed) characteristics n = f (I) of DC motor with separate / shunt /
series excitation.

Page 87
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
3.2. Mechanical characteristics of n = f (M) of DC motor with an separate / shunt / series excitation.
3.3. Operational characteristics n = f (P2), P1 = f (P2), M = f (P2), = f (P2) of DC motor with separate /shunt / series excitation.
3.4. Speed control of DC motor with separate / shunt / series excitation by armature voltage changing.
3.5. Speed control of a DC motor with separate / shunt/ series excitation by changing additional resistance in the armature circuit.
3.6. Speed control of a DC motor with separate / shunt excitation by field current change.
3.7. Speed control motor with series excitation by shunting field winding.
4. Three-phase squirrel-cage induction motor.
4.1. Electromechanical (speed) characteristic n = f (I).
4.2. Mechanical characteristic n = f (M).
4.3. Speed control of three-phase squirrel-cage induction motor by match stator voltage and frequency changing

Module / Component Pcs


1 Electromechanical unit (DC machine 101.2 , AC motor 106 and angular 1
displacement transducer)
2 Single-phase thyristor converter 1
3 Frequency converter 1
4 Single-phase power supply 1
5 Active load 1
6 Excitation rheostat of DC machine 1
7 Adjustable autotransformer 1
8 Rectifier 1
9 Rheostat 1
10 Single-phase transformer 1
11 Speed indicator 1
12 Module of 3 multimeters 1
13 Voltammeter 1
17 Basic Experiments Guide Single-phase transformer 1
14 Single-phase parameters meter 1
18 Basic Experiments Guide Fundamentals of electromechanics 1
15 Laboratory table with 2-section storagecontainer and 3-level frame 1
19 Operation manual 1
16 Set of accessories 1
20 Didactic materials CD 1

Page 88
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
16 Electric machines 1 Set Unit Prices Total Prices
Power consumption, VA 200 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
EM3M-S-R Please Contact Us
- single-phase AC circuit with P I C T U R E
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1600
Weight, Kg 75

BASIC EXPERIMENTS

1. Single-phase transformer.
1.1. Transformation ratio of single-phase transformer.
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase transformer.
1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) single-phase transformer.
1.4. Characteristic U = f (I) single-phase transformer with resistive load.
1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of single-
phase transformer at a resistive load.
3. DC generator with separate excitation.
2.1. Idling characteristic E0 = f (If) of DC generator with separate excitation.
2.2. Short-circuit characteristic IK = f (If) of DC generator with separate excitation.
2.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with separate excitation.
2.4. Characteristic U = f (I) of DC generator with separate excitation.
3. DC motor with shunt excitation.
3.1. Electromechanical (speed) characteristics n = f (I) of DC motor with shunt excitation.
3.2. Mechanical characteristics of n = f (M) of DC motor with shunt excitation.
4.

Page 89
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
3.3. Speed control of DC motor with shunt excitation by armature voltage changing.
3.4. Speed control of a DC motor with shunt excitation by field current change. Name Pcs
4. Three-phase squirrel-cage induction motor. 1 Electromechanical unit (DC machine 101.1 , AC motor 106 and angular 1
4.1. Electromechanical (speed) characteristic n = f (I). displacement transducer)
4.2. Mechanical characteristic n = f (M).
2 Frequency converter 1
4.3. Speed control of three-phase squirrel-cage induction motor by match stator
voltage and frequency changing 3 Single-phase power supply 1
4 Active load 1
5 Excitation rheostat of DC machine 1
6 Adjustable autotransformer 1
7 Rectifier 1
8 Single-phase transformer 1
9 Speed indicator 1
10 Module of 3 multimeters 1
11 Voltammeter 1
12 Single-phase parameters meter 1
13 Laboratory table with 2-section storagecontainer and 2-level frame 1
14 Set of accessories 1
15 Basic Experiments Guide Single-phase transformer 1
16 Basic Experiments Guide Fundamentals of electromechanics 1
17 Operation manual 1
18 Didactic materials CD 1

Page 90
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
17 Electric Machines 1 Set Unit Prices Total Prices
Power consumption, VA 200 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
-three-phase AC circuit with EM4M-S-R Please Contact Us
working neutral and protective leads P I C T U R E
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 2x910
- width 850
- height 1600
Weight, Kg 1750

BASIC EXPERIMENTS

1. Single-phase transformer.
1.1. Transformation ratio of single-phase transformer.
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase
transformer.
1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) single-
phase transformer.
1.4. Characteristic U = f (I) single-phase transformer with resistive load.
1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2)
of single-phase transformer with a resistive load.
1.6. Determination of equalizing current caused by inequality of transformation
ratios of parallel single-phase transformers.
1.7. Effect caused by the inequality of short-circuit voltages of single-phase
transformers operating in parallel.

Page 91
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
2. Single-phase autotransformer.
2.1. Transformation ratio of single-phase autotransformer.
2.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) of single-phase autotransformer.
2.3. Characteristic U = f (I) single-phase during resistive load.
3. Three-phase transformer.
3.1. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of three-phase transformer.
31.2. Short-circuit characteristics IK = f (U), RC = f (U), cosK = f (U) t of three-phase transformer.
3.3. Checking vector grouping of three-phase transformer.
3.4. Confirmation of impossibility of parallel operation of three-phase transformers with different vector grouping.
4. DC generators with separate / shunt excitation.
4.1. Idling characteristics E0 = f (If) of DC generator with separate excitation.
4.2. Short-circuit characteristics IK = f (If) of DC generator with separate excitation.
4.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with separate excitation.
4.4. Characteristic U = f (I) of DC generator with shunt excitation.
5. DC motors with separate/ shunt / series excitation.
5.1. Electromechanical (speed) characteristics n = f (I) of DC motor with separate / parallel / series excitation.
5.2. Mechanical characteristics of n = f (M) of DC motor with an separate / parallel / series excitation.
5.3. Operational characteristics n = f (P2), P1 = f (P2), M = f (P2), = f (P2) of DC motor with separate / parallel / series excitation.
5.4. Speed control of DC motor with separate / parallel / series excitation by armature voltage changing.
5.5. Speed control of a DC motor with separate / parallel / series excitation by changing additional resistance in the armature circuit.
5.6. Speed control of a DC motor with separate / shunt excitation by field current change.
5.7. Speed control motor with series excitation by shunting field winding.
6. Three-phase induction generator.
6.1. Ideal idling characteristics I0=f(U), Q0=f(U).
6.2. Energy characteristics =f(n), Q=f(n).
6.3. Operational characteristics n=f(), I=f(), Q=f(), cos=f(P).
7. Three-phase squirrel-cage induction motor.
7.1. Idling characteristics I0 = f (U), P0 = f (U), cos0 = f (U) .
7.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) .
7.3. Electromechanical (speed) characteristic n = f (I).
7.4. Mechanical characteristic n = f (M).
7.5. Operational characteristics I = f (P2), P1 = f (P2), s = f (P2), = f (P2), cos = f (P2), M = f (P2).
7.6. Speed control of three-phase squirrel-cage induction motor by stator voltage changing.
7.7. Speed control of three-phase squirrel-cage induction motor by match stator voltage and frequency changing.

Page 92
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Name Pcs
1 Electromechanical unit (DC machine 101.2, AC motor 106and angular displacement 1
transducer)
2 Three-phase power supply 1
3 DC motor power supply 1
4 Single-phase power supply 1
5 Three-pole breaker 2
6 Active load 1
7 Excitation rheostat of DC machine 1
8 Line reactor 1
9 Rectifier 1
10 Rheostat 1
11 Three-phase transformer group 2
12 Adjustable three-phase autotransformer 1
13 Speed indicator 1
14 Module of 3 multimeters 1
15 Voltmeter 1
16 Multifunctional electrical measuring instrument 1
17 Laboratory table with 2-level frame 1
18 Laboratory table with 2-section storage and 2-level frame 1
19 Set of accessories 1
20 Basic Experiments Guide Transformers and autotransformers 1
21 Basic Experiments Guide Electromechanics 1
22 Operation manual 1
23 Didactic materials CD 1

Page 93
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
18 Electric Machines 1 Set Unit Prices Total Prices
Power consumption, VA 500 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
-three-phase AC circuit with EM5M-S-R Please Contact Us
working neutral and protective leads P I C T U R E
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 2x910
- width 850
- height 1600
Weight, Kg 160

BASIC EXPERIMENTS

1. Single-phase transformer.
1.1. Transformation ratio of single-phase transformer.
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase
transformer.
1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) single-phase
transformer.
1.4. Characteristic U = f (I) single-phase transformer with resistive load.
1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of
single-phase transformer at a resistive load.
2. DC generators with separate / shunt excitation.
2.1. Idling characteristics E0 = f (If) of DC generator with separate excitation.
2.2. Short-circuit characteristics IK = f (If) of DC generator with separate
excitation.

Page 94
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
2.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with separate excitation.
2.4. Characteristic U = f (I) of DC generator with shunt excitation. Module / Component Pcs
1 Electromechanical unit (DC machine 101.2, AC 1
3. DC motors with separate/ shunt / series excitation. machine 102.1 and angular displacement
3.1. Electromechanical (speed) characteristics n = f (I) of DC motor with separate / shunt transducer)
/ series excitation. 2 Three-phase power supply 1
3.2. Mechanical characteristics of n = f (M) of DC motor with an separate
3 DC motor power supply 1
/ shunt / series excitation.
3.3. Operational characteristics n = f (P2), P1 = f (P2), M = f (P2), = f (P2) of DC motor 4 Synchronous machine exciter 1
with separate / shunt/ series excitation. 5 Single-phase power supply 1
3.4. Speed control of DC motor with separate / shunt / series excitation by armature 6 Three-pole breaker 2
voltage changing. 7 Active load 1
3.5. Speed control of a DC motor with separate / shunt/ series excitation by changing additional 8 Rheostat for AC machine rotor 1
resistance in the armature circuit. 9 Excitation rheostat of DC machine 1
3.6. Speed control of a DC motor with separate / shunt excitation by field current change.
10 Line reactor 1
3.7. Speed control motor with series excitation by shunting field winding.
4. Three-phase induction generator. 11 Rheostat 1
4.1. Ideal idling characteristics I0=f(U), Q0=f(U). 12 Single-phase transformer 1
4.2. Energy characteristics =f(n), Q=f(n). 13 Adjustable three-phase autotransformer 1
4.3. Operational characteristics n=f(), I=f(), Q=f(), cos=f(P). 14 Speed indicator 1
5. Three-phase squirrel-cage induction motor. 15 Module of 3 multimeters 1
5.1. Idling characteristics I0 = f (U), P0 = f (U), cos0 = f (U) .
16 Multifunctional electrical measuring instrument 1
5.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) .
5.3. Electromechanical (speed) characteristic n = f (I). 17 Laboratory table with 2-level frame 1
5.4. Mechanical characteristic n = f (M). 18 Laboratory table with 2-section storage and 2-level 1
5.5. Operational characteristics I = f (P2), P1 = f (P2), s = f (P2), = f (P2), cos = f (P2), M = f (P2). frame
5.6. Speed control of three-phase squirrel-cage induction motor by stator voltage changing. 19 Set of accessories 1
6. Three-phase synchronous generator. 20 Basic Experiments Guide Electric machines 1
6.1. Idling characteristic E0=f(If). 21 Operation manual 1
6.2. Short-circuit characteristic I=f(If).
22 Didactic materials CD 1
6.3. Characteristics U = f (I), If = f (I) and U = f (If).
7. Three-phase synchronous motor.
7.1. Asynchronous start.
7.2. U-curve characteristic I=f(If).
Operational characteristics I=f(P2), P1=f(P2, =f(P2), cos=f(P2), M=f(P2).

Page 95
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
19 Electric drives 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 500 EP2M-S-R Please Contact Us
Electric supply:
-three-phase AC circuit with P I C T U R E
working neutral and protective leads
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 3x910
- width 850
- height 1600
Weight, Kg 200

BASIC EXPERIMENTS

1. Mechanics of drives.
1.1. Determination of inertia moment of electric drive by method of free run-out.
1.2. Determination of mechanical characteristic of working mechanism.
2. Electric drive using DC motor with separate (shunt, series) excitation.
2.1 Determination of electromechanical and mechanical characteristics of electric
drive in motor, generator, and braking modes.
2.2. Speed control by changing resistance in armature circuit of DC motor.
2.3. Speed control by changing excitation current of DC motor.
2.4. Speed control by shunting field winding of DC motor with series excitation.
2.5. Speed control by changing armature voltage DC motor.

Page 96
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
2.6. Definition of energy parameters of electric drive with DC motor.
2.7. Measuring body temperature of DC motor. Module / Component Pcs
3. Electric drive using squirrel-cage induction motor. 1 Electromechanical unit with flywheel (DC machine 101.2, induction 1
3.1. Electromechanical and mechanical characteristics of electric drive with induction motor 106 and angular displacement transducer)
motor in motor, generator, and braking modes. 2 Three-phase power supply 1
3.2. Speed control by match changing frequency and magnitude of stator voltage . 3 Single-phase thyristor converter 1
3.3. Stator current and speed as function of time during transient. 4 Frequency converter 1
3.3. Definition of energy parameters of electric drive with induction motor .
5 Single-phase power supply 1
3.4. Measurement of body temperature of induction motor.
4. Open-loop control of electric drives. 6 Terminal 1
4.1. Induction squirrel-cage motor direct-on-line startup. 7 Active load 1
4.2. Induction squirrel-cage motor autotransformer startup. 8 Excitation rheostat of DC machine 1
4.3. Induction squirrel-cage motor reconnection startup. 9 Adjustable autotransformer 1
4.4. Induction squirrel-cage motor control during direct-on-line startup and dynamic 10 Rectifier 1
braking in function of time (plugging). 11 Rheostat 1
4.5. Induction squirrel-cage motor control during direct-on-line startup in function of time
12 Module of button control 1
(speed, EMF, stator current) and reverse in function of time (speed, EMF).
4.6. Thermal protection of induction squirrel-cage motor based on thermal electric relay. 13 Module of light signaling 1
4.7. Overcurrent protection of induction squirrel-cage motor based on automatic breaker. 14 Thermal electric relay 1
5. Closed-loop control of electric drives. 15 Automatic single-pole breaker 1
5.1. Thyristor converter - DC motor. 16 Automatic three-pole breaker 1
5.1.1. Control characteristics. 17 Three-phase transformer 1
5.1.2. Current control contour adjustment.
18 Three-phase transformer group 1
5.1.3. Limiter adjustment.
5.1.4. Speed control contour adjustment. 19 Terminal block 2
5.1.5. Determination of static electromechanical and mechanical characteristics. 20 Contactor 3
5.2. Frequency converter - induction motor . 21 Time relay 1
5.2.1. Speed control contour adjustment. 22 Auxiliary relay 1
5.2.2. Control characteristics. 23 Module of regulators 1
Determination of static electromechanical and mechanical characteristics. 24 Speed indicator 1
25 Module of 2 multimeters 1
26 Voltmeter 1
27 Ammeter 1

Page 97
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
28 Multifunctional electrical measuring instrument 1
29 Laboratory table with 2-level frame 1
30 Laboratory table with 2-section storage and 2-level frame 1
31 Laboratory table with storage container for wires and 2-level frame 1
32 Accessories Kit 1
33 Basic Experiments Guide Electric drives 1
34 Operation manual 1
35 Didactic materials CD 1
36 2-channel oscilloscope 1

Page 98
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
20 Single-phase transformer & autotransformer 1 Set Unit Prices Total Prices
Power consumption, VA 100 Type / Model ( Rupiah ) ( Rupiah )
Power supply:
- single-phase AC mains with OTAT1-S-R Please Contact Us
working neutral and protective wires P I C T U R E
- voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1250
Power consumption, VA 100
Name Pcs
1 Single-phase power supply 1
2 Line reactor 1
3 Adjustable autotransformer 1
4 Single-phase transformer 1
5 Module of 2 multimeters 1
6 Single-phase network parameters meter 1
7 Laboratory table with container and 1-level frame 1
8 Ac essories Kit 1
9 Basic Experiments Guide Single-phase transformer & autotransformer 1
10 Operating Manual 1
11 Didactic materials CD 1
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase
BASIC EXPERIMENTS transformer. 1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U)
1. Single-phase transformer. single-phase transformer.
1.1. Transformation ratio of single-phase transformer. 2. Single-phase autotransformer. 2.1. Transformation ratio of single-phase
autotransformer. 2.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f
(U) of single-phase autotransformer.

Page 99
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
21 Single-phase transformer & autotransformer 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 200 OTAT2M-S-R Please Contact Us
Power supply:
- single-phase AC mains with P I C T U R E
working neutral and protective wires
- voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1250
Weight, kg 45

BASIC EXPERIMENTS

1. Single-phase transformer.
1.1. Transformation ratio of single-phase transformer.
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase transformer.
1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) single-phase
transformer.
1.4. Characteristic U = f (I) single-phase transformer with resistive load.
1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of single-
phase transformer with a resistive load.
2. Single-phase autotransformer.
2.1. Transformation ratio of single-phase autotransformer.
2.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) of single-
phase autotransformer.
2.3. Characteristic U = f (I) single-phase during resistive load.

Page 100
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Single-phase power supply 1
2 Active load 1
3 Line reactor 1
4 Adjustable autotransformer 1
5 Single-phase transformer 1
6 Module of 2 multimeters 1
7 Single-phase network parameters meter 1
8 Laboratory table with container and 2-level frame 1
9 Accessories Kit 1
10 Basic Experiments Guide Single-phase transformer & autotransformer 1
11 Operating Manual 1
12 Didactic materials CD 1

Page 101
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
22 Rheostat starting & braking DC motor 1 Set Unit Prices Total Prices
2.1. Power consumption, VA 300 Type / Model ( Rupiah ) ( Rupiah )
2.2. Electric supply:
- single-phase AC circuit RPTDPT1-S-K Please Contact Us
with P I C T U R E
working neutral and 220 22
protective leads 50 0,5
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 2910
- length 850
- width 1250
- height
2.5. Weight, Kg 65

BASIC EXPERIEMENTS
1. Programmable relay.
1.1. Control of programmable relay.
1.2. Programming relay with computer aid.
1.3. Test of basic logic functions.
1.4. Test of special logic functions.
1.5. Test of commutation program.
2. Rheostat starting and breaking of DC motor
2.1. DC motor single-stage start as function of time.
2.2. DC motor single-stage start as function of EMF
2.3. DC motor single-stage start as function of current.
2.4. DC motor single-stage start as function of speed.
2.5. DC motor two-stage start as function of time.
2.6. DC motor single-stage start as function of time and dynamic braking as function of
EMF.
2.7. DC motor single-stage start as function of time and dynamic braking as function of
speed.
Page 102
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Single-phase Power Supply 1
2 Connector (4) 1
3 Programmable Relay Module 1
4 Button Control Module 1
5 DC Electric Drive 1
6 Laboratory Table 1
7 Computer Table 1
8 Accessories Kit 1
9 Basic Experiments Guide 1
10 Operation Manual 1
11 I/O Board 6023E/6024E/6025E User Manual 1
12 Didactic and Software CD 1
13 I/O Board 6023E 1
14 Personal Computer 1

Page 103
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
23 Open-loop Systems of Induction Motor Control Based on 1 Set Unit Prices Total Prices
Programmable Relay Type / Model ( Rupiah ) ( Rupiah )
RUADPR1-S-K Please Contact Us
Power consumption, VA 200 P I C T U R E
Electrical supply:
-three-phase AC circuit with
working neutral and protective leads
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 2x910
- width 850
- height 1600
Weight 80 Kg

BASIC EXPERIMENTS

1. Programmable relay.
1.1. Control of programmable relay.
1.2. Test of logic functions.
.Open-loop Systems of Induction Motor Control Based on Programmable Relay.
1.3. Direct-on-line start.
1.4. Star-delta start.
1.5. Direct-on-line start and dynamic braking as function of time.

1.6. Direct-on-line start and countercurrent braking as function of time.


1.7. Direct-on-line start and reverse.
1.8. Induction motor supply automatic back-up.

Page 104
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Induction motor with flywheel 1
2 Three-phase power supply 1
3 Rectifier 1
4 Rheostat 1
5 Module of button control 1
6 Module of light signaling 1
7 Thermal electric relay 1
8 Automatic single-pole breaker 1
9 Three-phase transformer 1
10 Contactor 2
11 Module of programmable relay 1
12 Voltmeter 1
13 Ammeter 1
14 Laboratory table with 1-level frame 1
15 Laboratory table with 2-section storage and 2-level frame 1
16 Accessories Kit 1
17 Basic Experiments Guide Open-loop Systems of Induction Motor Control Based on 1
Programmable Relay
18 Operation Manual 1
19 Didactic materials CD 1
20 Norebook 1

Page 105
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
24 Open-loop systems of DC motor control based on 1 Set Unit Prices Total Prices
programmable controller Type / Model ( Rupiah ) ( Rupiah )
2.1. Power consumption, VA 500 RUDPTK1-S-K Please Contact Us
2.2. Electric supply:
- single-phase AC circuit P I C T U R E
with
working neutral and 220 22
protective leads 50 0,5
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 2910
- length 850
- width 1600
- height
2.5. Weight, Kg 100

BASIC EXPERIMENTS

1.1. DC motor single-stage start as function of time.


1.2. DC motor single-stage start as function of EMF
1.3. DC motor single-stage start as function of current.
1.4. DC motor single-stage start as function of speed.
1.5. DC motor single-stage start as function of time and dynamic braking as function of
EMF.
1.6. DC motor single-stage start as function of time and dynamic braking as function of
speed.
Single-stage DC motor start as function of time and countercurrent braking

Page 106
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Electromechanical unit with flywheel (DC machine 101.1, Induction motor 106, and angular displacement transducer) 1
2 DC Voltage Source 1
3 Single-phase Power Supply 1
4 Rheostat 1
5 Pushbutton Control Module 1
6 Light Signaling Module 1
7 Contactor 3
8 Programmable Controller Module 1
9 Current-and-voltage Sensors Module 1
10 Speed Indicator 1
11 Voltammeter 1
12 Laboratory Table 1
13 Laboratory Table with 2-section Storage Container and 2-level Frame 1
14 Accessories Kit 1
15 Basic Experiments Guide 1
16 Operation Manual 1
17 Didactic and Software CD 1
18 Notebook 1

Page 107
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
25 Automated systems of DC motor control based on 1 Set Unit Prices Total Prices
programmable controller Type / Model ( Rupiah ) ( Rupiah )
SUDPTK1-S-K Please Contact Us
2.1. Power consumption, VA 500 P I C T U R E
2.2. Electric supply:
- single-phase AC circuit
with
working neutral and 220 22
protective leads 50 0,5
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 2910
- length 850
- width 1600
- height
2.5. Weight, Kg 100
BASIC EXPERIMENTS

1.1. DC motor single-stage start as function of time.


1.2. DC motor single-stage start as function of EMF
1.3. DC motor single-stage start as function of current.
1.4. DC motor single-stage start as function of speed.
1.5. DC motor single-stage start as function of time and dynamic braking as function of
EMF.
1.6. DC motor single-stage start as function of time and dynamic braking as function of
speed.
1.7. Single-stage DC motor start as function of time and countercurrent braking.
Study of open-loop and closed-loop control systems of DC motor

Page 108
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Electromechanical unit with flywheel (DC machine 101.1, Induction motor 106, and 1
angular displacement transducer)
2 DC Voltage Source 1
3 Single-phase Power Supply 1
4 Adjustable Autotransformer 1
5 Rectifier 1
6 Rheostat 1
7 Pushbutton Control Module 1
8 Light Signaling Module 1
9 Contactor 3
10 Programmable Controller Module 1
11 Current-and-voltage Sensors Module 1
12 Speed Indicator 1
13 Voltammeter 1
14 Laboratory Table 1
15 Laboratory Table with 2-section Storage Container and 2-level Frame 1
16 Accessories Kit 1
17 Basic Experiments Guide 1
18 Operation Manual 1
19 Didactic and Software CD 1
20 Notebook 1

Page 109
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
26 Transformers & autotransformers 1 Set Unit Prices Total Prices
Power consumption, VA, not more than 500 Type / Model ( Rupiah ) ( Rupiah )
Electrical supply:
-three-phase AC circuit with TAT1-S-R Please Contact Us
working neutral and protective leads P I C T U R E
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Class of protection against electrical shock I
Overall dimensions, mm, not more than
- length 910
- width 300
- height 1600
Weight, Kg, not more than 60
BASIC EXPERIMENTS

1. Single-phase transformer.
1.1. Transformation ratio of single-phase transformer.
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase transformer.
1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) of single-phase
transformer.
2. Single-phase autotransformer.
2.1. Transformation ratio of single-phase autotransformer.
2.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) of single-
phase autotransformer.
3. Three-phase transformer.
3.1. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of three-phase
transformer.
3.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) of three-
phase transformer.
3.3. Checking vector grouping of three-phase transformer

Page 110
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Three-phase power supply 1
2 Single-phase power supply 1
3 Line reactor 1
4 Three-phase transformer group 1
5 Adjustable three-phase autotransformer 1
6 Module of 3 multimeters 1
7 Multifunctional electric measuring instrument 1
8 Laboratory table with container and 2-level frame 1
9 Accessories Kit 1
10 Basic Experiments Guide Transformers & autotransformers 1
11 Operation Manual 1
12 Didactic materials CD 1

Page 111
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
27 Transformers & autotransformers 1 Set Unit Prices Total Prices
Power consumption, VA, not more than 500 Type / Model ( Rupiah ) ( Rupiah )
Electrical supply:
-three-phase AC circuit with TAT2M-S-R Please Contact Us
working neutral and protective leads P I C T U R E
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Class of protection against electrical shock I
Overall dimensions, mm, not more than
- length 910
- width 300
- height 1600
Weight, Kg, not more than 60

BASIC EXPERIMENTS

1. Single-phase transformer.
1.1. Transformation ratio of single-phase transformer.
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase transformer.
1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) single-phase
transformer.
1.4. Characteristic U = f (I) single-phase transformer with resistive load.
1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of single-
phase transformer with a resistive load.
1.6. Determination of equalizing current caused by inequality of transformation ratios of
parallel single-phase transformers.
1.7. Effect caused by the inequality of short-circuit voltages of single-phase transformers
operating in parallel.

Page 112
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Three-phase power supply 1
2 Single-phase power supply 1
3 Line reactor 1
4 Three-phase transformer group 1
5 Adjustable three-phase autotransformer 1
6 Module of 3 multimeters 1
7 Multifunctional electric measuring instrument 1
8 Laboratory table with 2-section container and 2-level frame 1
9 Accessories Kit 1
10 Basic Experiments Guide Transformers & autotransformers 1
11 Operation Manual 1
12 Didactic materials CD 1

Page 113
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
28 Relay-contactor control of induction squirrel-cage motor 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 1000 UADK1-P-R Please Contact Us
Electric supply:
- three-phase AC circuit with P I C T U R E
working neutral and protective leads
voltage, V 380 38
- frequency, Hz 50 0,5
Appliance class 0I
Total dimensions, mm (assembled)
- length 600
- width 550
- height 450
Weight, Kg 30
Module / Component Pcs
1 Induction Motor 107 1
2 Induction Motor Control Cabinet 1
3 Accessories Kit 1
4 Basic Experiments Guide 1
5 Operation Manual 1
6 Didactic Materials CD 1
BASIC EXPERIMENTS

1. .Assembling circuits and control of induction motor without reverse capability.


2. .Assembling circuits and control of induction motor with reverse capability.
3. Setting and checking of induction motor thermal protection, based on use of electr thermal
relay.
4. Programming microprocessor induction motor control and protection unit.
5. Setting and checking of induction motor thermal protection, based on use of. microprocessor
induction motor control and protection unit
6. Verifying induction motor current cutoff, based on use of circuit breaker..
7. Finding faults in induction motor control circuits.

Page 114
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
29 Relay-contactor control of induction squirrel-cage motor 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
2.1. Power consumption, VA 1000 UADK1-S-R Please Contact Us
2.2. Electric supply:
- three-phase AC circuit with P I C T U R E
working neutral and
protective leads 380 38
voltage, V 50 0,5
- frequency, Hz
2.3. Appliance class 0I
2.4. Total dimensions, mm
(assembled) 2750
- length 850
- width 1600
- height
2.5. Weight, Kg 200

BASIC EXPERIMENTS

1. Induction motor control with providing its direct start.


2. Induction motor control with providing its autotransformer start.
3. Induction motor control with providing its start by switching stator winding from star to
delta.
4. Induction motor control with providing its direct start and dynamic braking as function of
time.
5. Induction motor control with providing its direct start and reverse.
6. Automatic switching-on backup motor at voltage loss on main motor without
possibility of reverse.

Page 115
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
7. Automatic switching-on backup motor at voltage loss on main motor with possibility of reverse.
8. Operation of induction motor thermal protection, based on use of electric thermal relay.
9. Operation of induction motor overcurrent protection, based on use of automatic breaker.
10. Operation of induction motor overcurrent protection, based on use of overcurrent relay.
11. Operation of induction motor overcurrent protection with voltage blocking, based on use of overcurrent and undervoltage relays.
12. Induction motor control via push-button station and unit of control and protection without providing reverse.
13. Induction motor control via push-button station and unit of control and protection with providing reverse.
14. Induction motor control via unit of control and protection without providing reverse.
Induction motor control via unit of control and protection with providing reverse.

Module / Component Pcs 14 Terminal Board 4


1 Electromechanical Load with Flywheel (Two Induction motors 106) 1 15 Contactor 4
2 Three-phase Power Supply 1 16 Overcurrent Relay 1
3 Line Reactor 1 17 Undervoltage Relay 1
4 Rectifier 1 18 Induction Motor Current Protection Unit 1
5 Rheostat 1 19 Time Relay 1
6 Pushbutton Control Module 2 20 Auxiliary Relay 1
7 Light Signaling Module 2 21 Toggle Switch 2
8 Thermal Electrical Relay 2 22 Current Transformer 2
9 Three-pole Switch 1 23 Voltmeter 2
10 Automatic Single-pole Breaker 2 24 Ammeter 2
11 2 25 Laboratory Table with 2-level Frame 1
12 Three phase Transformer 1 26 Laboratory Table with 2-section Storage Container and 2-level Frame 1
13 Three-phase Autotransformer Group 1 27 Laboratory Table 1
28 Accessories Kit 1

Page 116
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
30 Relay-Contactor Control of Induction Squirrel-Cage Rotor 1 Set Unit Prices Total Prices
Motor Type / Model ( Rupiah ) ( Rupiah )
UADK2-N-R Please Contact Us
Power consumption, VA 1000 P I C T U R E
Electrical supply:
-three-phase AC circuit with
working neutral and protective leads
- voltage, V 380 38
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 2x910
- width 300
- height 800
Weight 150

BASIC EXPERIMENTS

1.1. Direct-on-line start.


1.2. Autotransformer start.
1.3. Star-delta start.
1.4. Direct-on-line start and dynamic braking as function of time.
1.5. Direct-on-line start and reverse.
6. Thermal protection based on thermal electric relay.
7. Overcurrent protection based on automatic breaker.

Page 117
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Name Pcs
1 Induction motor 1
2 Three-phase power supply 1
3 Rectifier 1
4 Rheostat 1
5 Module of button control 2
6 Module of light signaling 1
7 Thermal electric relay 1
8 Automatic single-pole breaker 1
9 Automatic three-pole breaker 1
10 Three-phase transformer 1
11 Three-phase autotransformer group 1
12 Terminal block 2
13 Contactor 3
14 Time relay 1
15 Auxiliary relay 1
16 Voltmeter 1
17 Ammeter 1
18 Desktop container with 2-level frame 2
19 Accessories Kit 1
20 Basic Experiments Guide Relay-Contactor Control of Induction Squirrel-Cage Rotor Motor 1
21 Operation Manual 1
22 Didactic materials CD 1

Page 118
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
POWER ELECTRONICS G A L S E N
No Name of Equipment Quantity
1 Multifunctional Transistor Converter 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Basic Experiments:
Autonomous voltage inverter (Determination of the parameters of 1-phase bridge MTP1-S-K Please Contact Us
autonomous voltage inverter during steady-state load; Simulation of modulated output voltage P I C T U R E
of 1-phase bridge autonomous voltage inverter during steady state load; Determination of the
harmonic components of 1-phase bridge autonomous voltage inverter during steady-state
load; Readout of load and frequency characteristics of 1-phase bridge autonomous voltage
inverter during steady-state load; Forming pulse-width modulation signals for 3-phase bridge
autonomous voltage inverter; Determination of the parameters of fre quency converter with
drop DC link and 3-phase bridge autonomous voltage inverter when loaded by motor)
Direct voltage pulse-width converter (Determination of parameters of reversible bridge
direct voltage pulse-width converter during steady-state load; Simulation of modulated output
voltage of output voltage of direct voltage pulse-width converter in accordance with the given
control mode; Determination the harmonic components of output voltage and current of
direct voltage pulse-width converter; Determination of parameters of reversible bridge direct
voltage pulse-width converter when loaded by motor)

Module / Components:
Motor-Generator Set (DC machine + Induction Motor + Angular Displacement Transducer);
Single-phase Power Supply; Terminal; Adjustable-ratio Autotransformer; Connector;
Multifunctional Transistor Converter; Loading Resistor; Choke; Single-phase Transformer; Unit
of Current and Voltage Sensors; Speed of Rotation Indicator; Two Multimeters Unit;
Voltmeters; Ampermeters;Laboratory Tables; Accessories Kit; Basic Experiments Guide; I/O
Board; Double-Channel Oscilloscope; Personal Computer

Page 119
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 DC Voltage Pulse-Width Converters 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Basic Experiments:
Unreversible pulse-width converters with reduced output voltage, controllable operating SHIPPN1-S-K Please Contact Us
R- L- load with counterEMF (series key and series-shunt key schemes). Unreversible pulse- P I C T U R E
width converter with incrised output voltage, controllable operating R- L- load with counterEMF
(shunt key scheme). Unreversible pulse-width converter with output voltage regulated higher
or lower than input voltage, controllable operating R- L- load with counterEMF Reversible
pulse-width converter, controllable operating R- L- load with counterEMF (key control,
symmetric and asymmetrical). Transients in pulse-width converters. Pulse-width converters
output voltage automatic control.
Modules / Components:
Power Supply; Single-phase Power Supply; Terminal; Active Load; Connector; Module
Of Digital Signals I/O; Pulse-width DC Converter; Pull-up Resistor; Choke; Module Of
Switching Capacitors; Module Of Current-and-voltage Sensors; Laboratory Table With 2-
section Storage And 2-level Frame; Laboratory Table With Computer Rack And Pullout
Keyboard Shelf And 2- level Frame; Accessories Kit; Basic Experiments Guide; Data
Acquisition Board; Personal Computer

Page 120
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
3 Industrial electronics 1 Set Unit Prices Total Prices
2.1. Power consumption, VA 500 Type / Model ( Rupiah ) ( Rupiah )
2.2. Electric supply:
- three-phase AC circuit with PE1-S-K Please Contact Us
working neutral and P I C T U R E
protective leads 380 38
voltage, V
- single-phase AC circuit
with 220 22
working neutral and 50 0,5
protective leads
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 3910
- length 850
- width 1600
- height
2.5. Weight, Kg 200

BASIC EXPERIMENTS
Analog electronics

1. Semiconductors.
1.1. Characteristics of semiconductor diodes for direct and alternating currents.
1.2. Main characteristics of stabilitron and study of parametric voltage regulator.
1.3. Current-voltage characteristics of LED.
1.4. Variable capacitance diode (varicap).
1.5. Test of p-n junctions of bipolar transistor and receiving its output characteristics
with an oscilloscope.

Page 121
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.6. Static characteristics of transistor for direct current.
1.7. Choice of bipolar transistor operating point and familiarization with AC voltage amplification mode of classes A, B, AB, and D.
1.8. Static characteristics of a field-effect transistor with p-n junction.
1.9. Static characteristics of field-effect transistor, insulated gate and induced channel.
1.10. Main characteristics of thyristors.
1.11. Basic characteristics and parameters of photocouplers. .
2. Electronic circuits and microcircuitry.
2.1. Comparative study of single amplifier stages using bipolar transistors.
2.2. Study of the amplifier stages using FET.
2.3. Study of two-stage transistor amplifier.
2.4. Study of the basic circuits of operational amplifier.
2.5. Study of operarional amplifier schemes.
2.6. Finding frequency characteristics of operational amplifier.
2.7. Summation, integration and differentiation schemes on operational amplifiers.
2.8. RC-filter using operational amplifier.
2.9. Simple logarithmic converter using operational amplifier.
2.10. Generator of sinusoidal oscillations using operational amplifier.
2.11. Schmitt trigger and relaxation oscillators using operational amplifier. .
2.12. RS-trigger, multivibrator and single-shot trigger.
2.13. Analog integrated comparators and circuits with them.
2.14. Self-oscillating and standby modes of analog timer using integrated chip.
2.15. Generator of special form voltage (function generator) using integrated chip.

3. Stabilizers and secondary sources of supply.


3.1. Half-wave and bridge-circuit rectifiers.
3.2. Three-phase bridge-circuit rectifier and smoothing filters.
3.3. Controlled rectifiers and thyrister regulator with phase control.
3.4. Degenerative voltage and current stabilizers.
3.5. Main schemes of coupling linear integral voltage regulator.
3.6. PWM DC-DC converter.
3.7. Integral pulse converter - voltage stabilizer with pulse-frequency modulation
Digit electronics

1. Testing basic logical elements.

Page 122
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
2. Assembly and test of simple combinational nodes of digital devices.
2.1. Combinational node using basic logic elements to implement arbitrary logic function.
2.2. Combinational nodes using basic logic elements for experimental confirmation of logic algebra laws.
2.3. Single-digit half-adder and adder.
2.4. Code converter and decoder.
2.5. Multiplexer and demultiplexer.
3. Assembly and test of sequential nodes of digital devices.
3.1. Triggers.
3.2. Counters.
3.3. Registers.

Power electronics

1. Rectifiers.
1.1. Modeling AC network..
1.2. Modeling main types of uncontrollable and controllable rectifiers.
1.3. Modeling rectifier loads. .
1.4. Regulating characteristics Ud = f(), Ud = f(UR) of three-phase bridge controllable rectifier operating on active-inductive load.
1.5. External characteristic Ud = f(Id) of three-phase bridge controllable rectifier operating on active-inductive load.
1.6. Parameters of valves of three-phase bridge controllable rectifier operating on active-inductive load.
1.7. Parameters of three-phase bridge controllable rectifier operating on active-inductive load.
1.8. Harmonics of rectified voltage and input current of three-phase bridge controllable rectifier operating on active-inductive load.
2. Dependent inverters.
2.1. Modeling DC power supply of dependent inverter.
2.2. Modeling main types of dependent inverters.
2.3. Input characteristic Ud = f(Id) of three-phase bridge dependent inverter.
2.4. Parameters of three-phase bridge dependent inverter operation.
2.5. Registration and display of mode parameters of single-phase bridge rectifier at its stalling.
3. Autonomous voltage inverter and double-link frequency converter.
3.1. Parameters of single-phase bridge autonomous voltage inverter operating on dead load.
3.2. Modeling modulated output voltage of single-phase bridge autonomous voltage inverter operating on dead load.
3.3. Harmonics of output voltage of single-phase bridge autonomous voltage inverter operating on dead load.
3.4. Finding external and frequency characteristics of single-phase bridge autonomous voltage inverter operating on dead load..
3.5. Forming PWM signals for three-phase bridge autonomous voltage inverter.
3.6. Parameters of frequency converter with intermediate DC link and three-phase bridge autonomous voltage inverter operating on motor load.

Page 123
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
4. Direct voltage pulse-width converters.
4.1. Parameters of reversible bridge direct voltage pulse-width converter operating on dead load.
4.2. Modeling output voltage of direct voltage pulse-width converter operating in accordance to given control law.
Harmonics of output voltage and current of direct voltage pulse-width converter. Parameters of reversible bridge direct voltage pulse-width converter operating on motor load

Module / Component Pcs 24 Speed Indicator 1


1 Electromechanical Unit (DC Machine 101.1, Induction Motor 106 and Angular 1 25 Multimeters Module (2 Multimeters) 2
Displacement Transducer) 26 Voltmeters Module 1
2 Three-phase Power Supply 1 27 Ammeters Module 1
3 Thyristor Converter/Controller 1 28 Mini-modules Set Fundamentals of digit technology 1
4 Voltage Generators & Testing Board 1 29 Mini-modules Set Analog electronics - Electric components 1
5 Single-phase Power Supply 1 30 Mini-modules Set Analog electronics - Electronic components 1
6 Module for Testing Digital Devices 1 31 Laboratory Table with 2-section Storage Container and 2-level Frame 2
7 Terminal 1 32 Laboratory Table with Computer Rack and 2-level Frame 1
8 Line Reactor 2 33 Accessories Kit 1
9 Adjustable Autotransformer 1 34 Basic Experiments Guide 1
10 Rectifier 1 35 Basic Experiments Guide 1
11 Rheostat 1 36 Basic Experiments Guide 1
12 Connector (4) 1 27 Basic Experiments Guide 1
13 Diodes Module 2 28 Operation Manual 1
14 Converter Transformer 2 39 I/O Board 6023E/6024E/6025E User Manual 1
15 Paralleling Reactor 1 40 Didactic and Software CD 1
16 Smoothing Capacitor 1 41 I/O Board 6024E w/adapter 1
17 Chokes Module 1 42 Two-channel Oscilloscope 1
18 Multifunctional Transistor Converter 1 43 Personal Computer 1
19 Load Resistor 1
20 Choke 1
21 Single-phase Transformer 1
22 Single-phase Transformer 1
23 Current-and-voltage Sensors Module 1

Page 124
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
4 Power electronics - Autonomous converters 1 Set Unit Prices Total Prices
2.1. Power consumption, VA 500 Type / Model ( Rupiah ) ( Rupiah )
2.2. Electric supply:
- single-phase AC circuit SE1-A-N-R Please Contact Us
with P I C T U R E
working neutral and 220 22
protective leads 50 0,5
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 920
- length 300
- width 800
- height
2.5. Weight, Kg 25

BASIC EXPERIMENTS

1. Direct voltage pulse-width converters.


1.1. Modeling main types of direct voltage pulse-width converters.
1.2. Registration of steady state parameters of irreversible series direct voltage pulse-
width converter operating on dead load.
1.3. Finding regulating characteristic of irreversible series direct voltage pulse-width
converter.
2. Autonomous current inverters and resonant inverters.
2.1. Modeling main types of single-phase current inverters and resonant inverters.
2.2. Registration of steady state parameters of single-phase shunt current inverter.
2.3. Finding input and external characteristics of single-phase shunt current inverter.
2.4. Manual regulating output voltage of single-phase shunt current inverter.

Page 125
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Power Supply 1
2 Single-phase Power Supply 1
3 Chokes Module 1
4 DC Pulse-Width Modulation Inverter 1
5 Autonomous Thyristor Converter 1
6 Load Resistor 1
7 Choke 2
8 Commutating Capacitors Module 1
9 Multimeters Module (3 Multimeters) 1
10 Two-level Desktop Frame with Container 1
11 Accessories Kit 1
12 Basic Experiments Guide 1
13 Operation Manual 1
14 Two-channel Oscilloscope 1

Page 126
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
5 Power electronics - Autonomous converters 1 Set Unit Prices Total Prices
2.1. Power consumption, VA 500 Type / Model ( Rupiah ) ( Rupiah )
2.2. Electric supply:
- three-phase AC circuit with SE1-A-S-K Please Contact Us
working neutral and P I C T U R E
protective leads 380 38
voltage, V
- single-phase AC circuit
with 220 22
working neutral and 50 0,5
protective leads
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 1850
- length 850
- width 1600
- height
2.5. Weight, Kg 150
BASIC EXPERIMENTS

3. Direct voltage pulse-width converters.


3.1. Modeling main types of direct voltage pulse-width converters.
3.2. Registration of steady state parameters of irreversible series direct voltage pulse-
width converter operating on dead load.
3.3. Finding regulating characteristic of irreversible series direct voltage pulse-width
converter.
4. Autonomous current inverters and resonant inverters.
4.1. Modeling main types of single-phase current inverters and resonant inverters.
4.2. Registration of steady state parameters of single-phase shunt current inverter.
4.3. Finding input and external characteristics of single-phase shunt current inverter.
Manual regulating output voltage of single-phase shunt current inverter

Page 127
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Power Supply 2
2 Single-phase Power Supply 1
3 Terminal 1
4 Active Load 2
5 Connector (4) 1
6 Digital Signals I/O Module 1
7 Chokes Module 1
8 DC Pulse-Width Modulation Inverter 1
9 Autonomous Thyristor Converter 1
10 Load Resistor 1
11 Choke 2
12 Commutating Capacitors Module 1
13 Current-and-voltage Sensors Module 1
14 Multimeters Module (2 Multimeters) 1
15 Laboratory Table with 2-section Storage Container and 2-level Frame 1
16 Laboratory Table with Computer Rack and 2-level Frame 1
17 Accessories Kit 1
18 Basic Experiments Guide 1
19 Operation Manual 1
20 I/O Board 6023E/6024E/6025E User Manual 1
21 Didactic and Software CD 1
22 I/O Board 6024E w/adapter 1
23 Personal Computer 1

Page 128
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
6 Power electronics - Autonomous converters 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
2.1. Power consumption, VA 500 SE1-A-S-R Please Contact Us
2.2. Electric supply:
- single-phase AC circuit P I C T U R E
with
working neutral and 220 22
protective leads 50 0,5
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 910
- length 850
- width 1600
- height
2.5. Weight, Kg 60
BASIC EXPERIMENTS

1. Direct voltage pulse-width converters.


a. Modeling main types of direct voltage pulse-width converters.
b. Registration of steady state parameters of irreversible series direct voltage
pulse-width converter operating on dead load.
c. Finding regulating characteristic of irreversible series direct voltage pulse-
width converter.
2. Autonomous current inverters and resonant inverters.
a. Modeling main types of single-phase current inverters and resonant
inverters.
b. Registration of steady state parameters of single-phase shunt current
inverter.
c. Finding input and external characteristics of single-phase shunt current
inverter. Manual regulating output voltage of single-phase shunt current
inverter

Page 129
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Power Supply 1
2 Single-phase Power Supply 1
3 Chokes Module 1
4 DC Pulse-Width Modulation Inverter 1
5 Autonomous Thyristor Converter 1
6 Load Resistor 1
7 Choke 2
8 Commutating Capacitors Module 1
9 Multimeters Module (3 Multimeters) 1
10 Laboratory Table with 2-section Storage Container and 2-level Frame 1
11 Accessories Kit 1
12 Basic Experiments Guide 1
13 Didactic CD 1
14 Two-channel Oscilloscope 1

Page 130
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
7 Power electronics - Autonomous and driven 1 Set Unit Prices Total Prices
by supply network converters Type / Model ( Rupiah ) ( Rupiah )
SE1-VA-S-K Please Contact Us
P I C T U R E

2.1. Power consumption, VA 500


2.2. Electric supply:
- three-phase AC circuit
with
working neutral and 380 38
protective leads
voltage, V
- single-phase AC circuit 220 22
with 50 0,5
working neutral and
protective leads
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 3650
- length 850
- width 1600
- height
2.5. Weight, Kg 300

Page 131
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS
Rectifiers.
4.3. Modeling AC network.
4.4. Modeling main types of uncontrollable and controllable rectifiers.
4.5. Modeling rectifier loads. .
4.6. Regulating characteristics Ud = f(), Ud = f(UR) of three-phase bridge controllable rectifier operating on active-inductive load.
4.7. External characteristic Ud = f(Id) of three-phase bridge controllable rectifier operating on active-inductive load.
4.8. Parameters of three-phase bridge controllable rectifier operating on active-inductive load.
4.9. Harmonics of rectified voltage and input current of three-phase bridge controllable rectifier operating on active-inductive load.
4.10. Automatic control of three-phase bridge rectifier operating on active-inductive load.
4.11. Registration and display of mode parameters at short-circuit in -phase bridge uncontrollable rectifier operating on active-inductive load. .
4.12. Modeling three-phase bridge controllable rectifier operating as current source on active-inductive load.
5. Ripple filters.
5.1. Modeling ripple filters based on RLC passive elements.
5.2. Defining smoothing factor of LC-filter in DC circuit of three-phase bridge controllable rectifier operating on active load.
6. Dependent inverters.
6.1. Modeling DC power supply of dependent inverter.
6.2. Modeling main types of dependent inverters.
6.3. Input characteristic Ud = f(Id) of three-phase bridge dependent inverter.
6.4. Parameters of three-phase bridge dependent inverter operation.
6.5. Automatic control of three-phase bridge inverter operation.
6.6. Registration and display of mode parameters of single-phase bridge rectifier at its stalling.
7. Rectifier-inverter converters.
7.1. Modeling parallel operation of three-phase bridge uncontrollable rectifier and inverter on dead load with counterEMF.
7.2. Modeling parallel operation of single-phase bridge uncontrollable rectifier and inverter on DC motor.
8. Reversible converters.
8.1. Modeling reversible converter with common control operating on DC motor.
8.2. Modeling reversible converter with computer control operating on DC motor.
9. Frequency converters direct-coupled.
9.1. Modelling three-phase direct-coupled converter made according to mid-point scheme operating on active-inductive load (one phase).
9.2. Modelling three-phase direct-coupled converter made according to bridge scheme operating on active-inductive load (one phase).
10. Thyristor alternating voltage regulator.
10.1. Parameters of single-phase alternating voltage regulator operating on active-inductive load.
10.2. Automatic three-phase load voltage control with static thyristor compensator of reactive power.

Page 132
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
11. Direct voltage pulse-width converters. 13 Adjustable Autotransformer 1
11.1. Modeling main types of direct voltage pulse-width converters. 14 Rectifier 1
11.2. Registration of steady state parameters of irreversible series direct voltage pulse-width converter 15 Rheostat 1
operating on dead load. 16 Inductive Load 1
11.3. Regulating characteristic of of irreversible series direct voltage pulse-width converter. 17 Connector (4) 1
11.4. Automatic control of output voltage of irreversible series direct voltage pulse-width converter 18 Digital Signals I/O Module 1
11.5. operating on dead load.
12. Autonomous current inverters and resonant inverters. 19 Diodes Module 2
12.1. Modeling main types of single-phase current inverters and resonant inverters. 20 Converter Transformer 2
12.2. Registration of steady state parameters of single-phase shunt current inverter. 21 Paralleling Reactor 1
12.3. Finding input and external characteristics of single-phase shunt current inverter. 22 Smoothing Capacitor 1
12.4. Manual regulating output voltage of single-phase shunt current inverter. 23 Chokes Module 2
12.5. Automatic control of output voltage of single-phase shunt current inverter by changing its 24 1
input voltage.
25 DC Pulse-Width Modulation Inverter 1
12.6. Automatic stabilizing output voltage of single-phase shunt current separately excited inverter
12.7. by reactive power compensation 26 Autonomous Thyristor Converter 1
Module / Component Pcs 27 Load Resistor 1
1 Electromechanical unit with flywheel (DC machine 101.1, Induction motor 106, and 1 28 Choke 2
angular displacement transducer) 29 Commutating Capacitors Module 1
2 Three-phase Power Supply 1 30 Current-and-voltage Sensors Module 1
3 Thyristor Converter/Controller 1 31 Speed Indicator 1
4 Thyristor Converter/Controller 1 32 Multimeters Module (2 Multimeters) 2
5 Power Supply 2 33 Laboratory Table with 2-level Frame 1
6 Single-phase Power Supply 1 34 Laboratory Table with 2-section Storage Container and 2- 2
7 Three-pole Breaker 1 level Frame
8 Terminal 1 35 Laboratory Table with Computer Rack and 2-level Frame 1
9 Active Load 1 36 Accessories Kit 1
10 Active Load 2 37 Basic Experiments Guide 1
11 Line Reactor 2 38 Basic Experiments Guide 1
12 Capacitive Load 1 39 Operation Manual 1

Page 133
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
8 Power electronics - Rectifiers & Dependent inverters 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
2.1. Power consumption, VA 500 SE1-VI-S-R Please Contact Us
2.2. Electric supply:
- three-phase AC circuit with P I C T U R E
working neutral and
protective leads 380 38
voltage, V
- single-phase AC circuit
with 220 22
working neutral and 50 0,5
protective leads
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 2910
- length 850
- width 1600
- height
2.5. Weight, Kg 120
BASIC EXPERIMENTS
1. Rectifiers.
1.1. Modeling AC network.
1.2. Modeling main types of uncontrollable and controllable rectifiers.
1.3. Modeling rectifier loads.
1.4. Regulating characteristics Ud = f(), Ud = f(UR) of three-phase bridge controllable
rectifier operating on active-inductive load.
1.5. External characteristic Ud = f(Id) of three-phase bridge controllable rectifier operating
on active-inductive load.
2. Dependent inverters.
2.1. Modeling DC power supply of dependent inverter.
2.2. Modeling main types of dependent inverters.
Input characteristic Ud = f(Id) of three-phase bridge dependent inverter

Page 134
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Three-phase Power Supply 1
2 Thyristor Converter/Controller 1
3 Single-phase Power Supply 1
4 Terminal 1
5 Line Reactor 2
6 Adjustable Autotransformer 1
7 Rectifier 1
8 Rheostat 1
9 Diodes Module 2
10 Converter Transformer 2
11 Paralleling Reactor 1
12 Smoothing Capacitor 1
13 Chokes Module 1
14 Multimeters Module (2 Multimeters) 2
15 Laboratory Table with 2-level Frame 1
16 Laboratory Table with 2-section Storage Container and 2-level Frame 1
17 Accessories Kit 1
18 Basic Experiments Guide 1
19 Operation Manual 1
20 - 1

Page 135
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
9 Power electronics - Autonomous 1 Set Unit Prices Total Prices
converters Type / Model ( Rupiah ) ( Rupiah )
SE2-A-S-K Please Contact Us
P I C T U R E

2.1. Power consumption, VA 500


2.2. Electric supply:
- three-phase AC circuit
with
working neutral and 380 38
protective leads
voltage, V
- single-phase AC circuit 220 22
with 50 0,5
working neutral and
protective leads
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 3910
- length 850
- width 1600
- height
2.5. Weight, Kg 200

Page 136
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Electromechanical Unit (DC Machine 101.1, Induction Motor 106 and Angular 1 28 Basic Experiments Guide 1
Displacement Transducer) 29 Operation Manual 1
2 Power Supply 2 30 I/O Board 6023E/6024E/6025E User Manual 1
3 Single-phase Power Supply 1 31 Didactic and Software CD 1
4 Terminal 1 32 I/O Board 6024E w/adapter 1
5 Active Load 2 33 Two-channel Oscilloscope 1
6 Adjustable Autotransformer 1 34 Personal Computer 1
7 Connector (4) 1
8 Digital Signals I/O Module 1 BASIC EXPERIMENTS
9 Chokes Module 1 Direct voltage pulse-width converters.
10 DC Pulse-Width Modulation Inverter 1 Modeling main types of direct voltage pulse-width converters.Registration of
steady state parameters of irreversible series direct voltage pulse-width converter
11 Multifunctional Transistor Converter 1
operating on dead load. Finding regulating characteristic of irreversible series
12 Autonomous Thyristor Converter 1 direct voltage pulse-width converter. Automatic regulation of output voltage of
13 Load Resistor 1 irreversible series pulse-width direct voltage converter operating on dead load.
14 Choke 2 Parameters of reversible bridge pulse-width direct voltage converter (based on
15 Commutating Capacitors Module 1 multifunctional transistor converter). Modeling output voltage of pulse-width direct
16 Single-phase Transformer 1 voltage converter in accordance with given control law (based on multifunctional
17 Single-phase Transformer 1 transistor converter). Harmonics of output voltage and current of pulse-width direct
voltage converter (based on multifunctional transistor converter).
18 Current-and-voltage Sensors Module 1 Parameters of reversible bridge pulse-width direct voltage converter operating on
19 Speed Indicator 1 motor load. (based on multifunctional transistor converter).
20 Multimeters Module (2 Multimeters) 1 Autonomous current inverters and resonant inverters.
21 Voltmeters Module 1 Modeling main types of single-phase current inverters and resonant inverters.
22 Ammeters Module 1 Registration of steady state parameters of single-phase shunt current inverter.
23 Laboratory Table with 2-level Frame 1 Finding input and external characteristics of single-phase shunt current inverter.
Manual regulating output voltage of single-phase shunt current inverter.
24 Laboratory Table with 2-section Storage Container and 2-level Frame 1
Automatic control of output voltage of single-phase shunt current inverter by
25 Laboratory Table with Computer Rack and 2-level Frame 1 changing its input voltage. Automatic stabilizing output voltage of single-phase
26 Accessories Kit 1 shunt current separately excited inverter by reactive power compensation.
27 Basic Experiments Guide 1

Page 137
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
10 Direct voltage pulse-width converters 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
2.1. Power consumption, VA 500 SHIPPN1-S-R Please Contact Us
2.2. Electric supply:
- single-phase AC circuit P I C T U R E
with
working neutral and 220 22
protective leads 50 0,5
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 910
- length 850
- width 1600
- height
2.5. Weight, Kg 50
BASIC EXPERIMENTS
1. Irreversible pulse-width converters with lower output voltage and controllable R- L load
(schemes: with series key, with series and shunt keys).
2. Irreversible pulse-width converters with overrating output voltage and controllable R- L
load (scheme with shunt key).
3. Irreversible pulse-width converters with output voltage higher and lower than input voltage
and controllable R- L load (scheme with series key and shunt energy storage reactor).
4. Reversible pulse-width converter with controllable R- L load ( key control: symmetrical,
asymmetrical).

Page 138
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Power Supply 1
2 Single-phase Power Supply 1
3 Active Load 1
4 DC Pulse-Width Modulation Inverter 1
5 Load Resistor 1
6 Choke 2
7 Commutating Capacitors Module 1
8 Multimeters Module (2 Multimeters) 1
9 Laboratory Table with 2-section Storage Container and 2-level Frame 1
10 Accessories Kit 1
11 Basic Experiments Guide 1
12 Operation Manual 1
13 Didactic CD 1
14 Two-channel Oscilloscope 1

Page 139
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
ELECTRICITY SUPPLY SYSTEMS G A L S E N
No Name of Equipment Quantity
1 Electricity Supply Systems 1 Set Unit Prices Total Prices
Basic Experiments Type / Model ( Rupiah ) ( Rupiah )
Steady-state modes of elements of electric distribution network (Full-scale simulation of
steady-state mode of single-phase transformer; Full-scale simulation of steady-state mode of RESOR1-S-K Please Contact Us
one phase of network; Readout of static characteristics of the power for static load) P I C T U R E
Steady-state modes of the power distribution network (Full-scale simulation of steady-state
mode of one phase of network with single-sided supply / two-sided supply)
Voltage regulation in electric distribution network
(Counter voltage regulation; Voltage regulation by cross compensation of reactive power
with capacitor banks)
Optimization of the local electricity distribution network modes (Detecting active power losses
in local power distribution network composed by loop scheme; Evaluation of effect of
difference in the voltages at busbars of power centers on loss of active power in local electric
distribution network, composed by loop scheme, when it operates in closed mode; Evaluation
of effect of rupture of local electric distribution network, composed by loop scheme, on loss of
active power; Finding point of normal (optimal) rupture in local electric distribution network,
composed by loop scheme, according to the criterion of minimum active power losses;
Operation of local electric distribution network, made by loop scheme, in mode of automatic
point selection of normal (optimal) rupture according to the criterion of minimum active power
losses) Optimization of the regional electricity distribution network modes (Measurement and
calculation of closed (circular) regional electric distribution network mode parameters; Finding
optimal power of the compensating capacitors in closed (circular) regional electric distribution
network according to the criterion of minimum active power losses)
Modules / Components
Single-Phase Power Supply; Electric Transmission Line Model; Capacitive Load; Single-Phase
Transformer; Transformer Substation and Load Model; Electric Network Parameters
Measurement Tool; Laboratory Table With 3-Level Frame, Container and Rack; Accessories
Kit; Basic Experiments Guide; Software CD-ROM; Uninterruptible Power Supply; Notebook

Page 140
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 Power Distribution Grid 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Basic Experiments: RSSES1M-N-R Please Contact Us
Electric loads modes (Power vs Voltage static characteristic of resistive load. Power vs
Voltage static characteristic of reactor. Power vs Voltage static characteristic of capacitive P I C T U R E
load)
Distribution network modes (Modeling steady state operation of single-phase transformer.
Modeling steady state operation of a phase of transmission line. Modeling steady state
operation of a phase of open-loop network phase single feed. Voltage regulation of open-loop
power distribution grid by shunt reactive power compensation using capasitor package)

Modules / Components:
Single-phase Power Supply; Active Load; Model Of Transmission Line; Capacitive Load;
Adjustable Autotransformer; Inductive Load; Power Meter Commutater; Automatic Single-pole
Switch; Singlephase Transformer; Module Of Two Multimeters; Single-phase Grid; Parameters
Meter; Desktop Container with 2-level Frame; Accessories Kit; Basic Experiments Guide

Page 141
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
3 Relay Protection & Automation In Electricity Supply Systems 1 Set Unit Prices Total Prices
(Based on Electromagnetic Relays) Type / Model ( Rupiah ) ( Rupiah )
Basic Experiments: RZASESR1-N-R Please Contact Us
Relay protection (Transmission line highset overcurrent protection. Transmission line instant
current cutoff. High-set overcurrent protection of radial electrical network with single supply. P I C T U R E
Transmission line differential protection. Transformer differential protection. Transmission line
circuit breaker high-set overcurrent protection. Thermal electrical relay thermal protection of
electrical network)
Automation (Automatic activation of backup of electrical load supply. Transmission line
autoreclosing

Modules / Components:
Single-phase Power Supply; Electrical Transmission Line Model; Push-button Control Station;
Light Signaling Module; Electrothermal Relay; Automatic Singlepole Switch; Contactor;
Overcurrent Relay; Undervoltage Relay; Time Relay; Interposing Relay; Single-phase
Transformer; Current Transformer; Current & Time Meter; Two-level Frame With Container;
Accessories Kit; Basic Experiments Guide

Page 142
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
4 Electric Safety in Power Supply Systems 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Effect of electric current on human being (Determination of electric current through human
body at direct touch to parts under voltage. Determination of electric current through human EBSES2-N-R Please Contact Us
body at indirect touch to parts under voltage. Determination of human body resistance) P I C T U R E
Measures to protect human being from electric shock (Action of protective neutral
grounding. Protective effect of automatic power-off when overcurrent. Protective effect of
appliance double insulation Operation of protective switching device. Operation of protective
grounding. Phase insulation monitoring in grid with insulated neutral)
Protection from electric shock in installations (with grounding TN-C, TN-S, TN-C-S , TT,
TI, IT: Protection operating at direct human touch to parts under voltage, Protection operating
at damage of appliance system insulation, Protection operating at mistaken joining neutral,
system and protective conductors, etc

Modules / Components:
Single-phase Power Supply; Model Of Grid Section; Human Being Simulator; Protective
Switching Device; Automatic Single-pole Breaker; Model Of Supply Grid; Model Of Appliance
With Working Insulation; Model Of Grounding; Module Of Two Multimeters; Desktop Container
With 2- level Frame; Accessories Kit; Basic Experiments Guide

Page 143
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
ELECTRIC POWER ENGINEERING G A L S E N
No Name of Equipment Quantity
1 Model of Single-Generator 1 Set Unit Prices Total Prices
Electric Power System Type / Model ( Rupiah ) ( Rupiah )
EE2-B-S-K Please Contact Us
P I C T U R E
List of Basic Experiments:
Production of electrical energy (Manual / automated /
automatic: turning on of synchronous generator for parallel
operation in a manner of self-synchronization, turning on of
synchronous generator in parallel operation by the method
of precise synchronization; manual / automated frequency
and voltage regulation of autonomously operating
synchronous generator; voltage and active power control
of synchronous generator operating in parallel with
electrical system of almost infinite power; dampening field
of synchronous generator; operation of synchronous
generator in asynchronous mode; Start and regulation of
reactive power of the synchronous condenser; Direct /
reactor start of induction motor; asynchronous start of
synchronous motor)
Steady-state operation of electrical networks (Study of
symmetric steady state operation of three-phase electrical
network with single feed; Study of symmetric steady state
operation of three-phase mains with dual feed; Study of
asymmetrical steady state operation of threephase
electrical network with single feed; Controlling activities of
autonomous electrical system)
Transients in power systems Electromagnetic
transients (Study of: connecting transformer to network

Page 144
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
load with three-phase short circuit in the electrical network supplied by a source of almost infinite Modules & Components
power, with a three-phase short circuit in the electrical network supplied by a synchronous Dynamoelectric Machine with Flywheel (with DC Machine, AC Machine and
generator, with asymmetrical short circuits in the electrical network, supplied by an almost infinite Angular Encoder) Three-phase Power Supply;DC Motor Power
capacity, with single longitudinal asymmetry in the electrical network, with Supply;Synchronous Machine Exciter;Single-phase Power Supply; Three-pole
multiple asymmetry in the electrical network) Circuit Breaker ; Terminal Resistive Load ; Power Line Modeal ; Line Reactor ;
Electromechanical transients in singlegenerator electrical system (Study of: connecting to Series Capacitance Device ; Capacitive Load ; Synchronization Unit ; Inductive
network of synchronous generator using precise timing, methods of selfsynchronization; Readout load Connector ; Digital Signals I/O Unit ; Three-phase Transformer Group
of angular characteristics and determination of the limit of the active power of the synchronous Power meter Switchboard ; Varistors Unit ; Measuring Current and Voltage
generator, Investigation of the influence of parameters of elements (transmission lines, series Transformers Unit ; Current and Voltage Sensors Unit ; Voltage and Frequency
capacitance device, receptor electrical system), scheme (intermediate selection of active and / Meter ; The angle of the synchronous machine load ; Pointer speed ; Power
or reactive power, intermediate reactive power generation) and mode (power line voltage, Meter ; Three Multimeters Unit ; Laboratory Table ; Accessories Kit ;Basic
excitation regulation of the generator and its power factor) on the stability of the synchronous Experiments Guide ; Personal Computer with I/O Board
generator; Investigation of the effect on stability of synchronous generator of known types of
short circuit; Investigation of influence of the form of short circuit in critical time; study the effect
of load on the synchronous generator time limit short-circuit breaking; Investigation of transition
of synchronous generator into asynchronous mode due to over-active power or loss of excitation
or short-circuit on power line linking it with receptor electrical system; Investigation of the
processes of resynchronization generator to the network)
Relay protection of electric power systems (Overcurrent protection transmission line with
single feed) Automation of electric power systems (threephase reclosing of transmission lines
with single feed)

Page 145
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 Electric System Model with Asynchronized 1 Set Unit Prices Total Prices
Synchronous Generator Type / Model ( Rupiah ) ( Rupiah )
EE1M-ASG-S-K Please Contact Us
P I C T U R E
Basic Experiments:
Main equipment of electric power stations and
substations (Synchronous generators. Power
transformers. Synchronous compensators)
Auxiliary needs of electric power stations and
substations (Direct-on-line / reactor start of induction
motor. Self-running of induction motor)
Electric power systems and grid (Steady states of
electric grid elements. Steady states of electric grid.
Steady states of electric power system. Voltage regulation
in grid)
Transients in electric power systems (Electromagnetic
transients. Electromechanical transients)
Relay protection of electric power systems (Protection
of transmission lines. Busbar protection. Power
transformer protection. Relay protection and breakers
back-up. Synchronous generator protection. Generator-
transformer unit protection. Induction motor protection. )

Page 146
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Automation of electric power systems normal modes (utomatic switching-in Modules / Components:
synchronous generator in parallel. Frequency and active power automatic control. Voltage Electromechanical unit with flywheel (induction motor, AC machine, and angular
and reactive power automatic control. Automatic control of electric power system mode) displacement transducer); Three-phase power supply; Synchronous machine exciter;
Emergency automation of electric power systems (Automation of fault clearing, Single-phase power supply; Turbine model power supply; Three-pole breaker;
reclosing and back-up. Automatic stability control. Automatic asynchronous mode Terminal; Active load; Model of transmission line; Line reactor; Series capacitive
prevention. Automatic prevention of unacceptable changes of regime parameters) compensating device; Capacitive load; Module of synchronizing Inductive load;
Steady states of asynchronized synchronous generator in electric power system Connector; Module of digital signals I/O; Module of diodes;Threephase transformer
(Idling characteristics of asynchronized synchronous generator. Switching-in group; Power meter commutater; Module of varistors; Module of current-and-voltage
asynchronized synchronous generator on parallel operation by ideal synchronization. transformers; Module of current-and-voltage sensors; Voltage-and-frequency meter;
Regulating characteristics of asynchronized synchronous generator at parallel operation) Synchronous machine torque angle meter; Speed indicator; Power meter; Module of
three multimeters; Multifunctional electrical measuring instrument; Laboratory tables;
Accessories Kit; Basic Experiments Guide; Personal computer with Software

Page 147
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
3 Electric Power Systems 1 Set Unit Prices Total Prices
and Grid Type / Model ( Rupiah ) ( Rupiah )
EE2M-ESS-S-R Please Contact Us
P I C T U R E
Basic Experiments:
Steady states of electric grid elements (Modeling steady
state of three-phase transformer. Modeling steady state of
three-phase transmission line) Steady states of electric
grid (Modeling steady state of an electric grid phase with
single supply. Modeling steady state of an electric grid
phase with duplicate supply. Modeling steady state of
threephase electric grid with single supply
Steady states of electric power system (Consumed
active/reactive power effect on electric power system
mode. Generated active/reactive power effect on electric
power system mode)
Voltage regulation in grid (Counter voltage regulation.
Voltage regulation by shunt reactive power compensation
using capacitor package. Voltage regulation by series
reactive power compensation using capacitor package)

Modules / Components:
Electromechanical unit with flywheel (induction motor, AC machine, and angular displacement transducer); Three-phase
power supply; Synchronous machine exciter; Single-phase power supply; Turbine model power supply; Three-pole
breaker; Active load; Model of transmission line; Series capacitive compensating device; Capacitive load; Inductive load;
Three-phase transformer group; Power meter commutater; Speed indicator; Multifunctional electrical measuring
instrument; Laboratory table with 2-level frame; Laboratory table with 2-section storage container and 2-level frame;
Accessories Kit; Basic Experiments Guide

Page 148
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
4 Relay Protection and Automation 1 Set Unit Prices Total Prices
of Electric Power Systems Type / Model ( Rupiah ) ( Rupiah )
EE2M-RZAES-S-K Please Contact Us
P I C T U R E
Basic Experiments:
Relay protection of electric power systems Schemes
of measuring transformers connection (Schemes of
current transformers connection.Schemes of voltage
transformers connection) Protection of transmission
lines (Overcurrent protection / cutoff of two transmission
lines with single supply. Directional current protection of
transmission lines in ring grid. Ground fault protection of
grid with big ground fault current. Nonselective alarm of
ground fault in grid with small ground fault current.
Longitudinal differential protection of transmission line.
Transverse differential protection of parallel transmission
lines. Distance protection of transmission lines in grid with
duplicate supply) Busbar protection (Differential
protection. Current busbar cutoff. Distance busbar
protection) Power transformer protection (Differential
protection. Overcurrent protection. Negative phase-
sequence transformer protection. Zero-sequence current
transformer protection) Relay protection and breakers
back-up (Circuit- breaker failure protection) Synchronous
generator protection (Differential protection. Overload
protection) Generator-transformer unit protection
(Differential protection) Induction motor protection
(Overcurrent protection. Differential protection. Low-
voltage protection)

Page 149
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Automation of electric power systems normal modes Automatic switching-in Modules / Components:
synchronous generator in parallel (by coarse synchronization; by ideal Electromechanical unit with flywheel (induction
synchronization) Frequency and active power automatic control (Autonomous motor, AC machine, and angular displacement
electric power system frequency automatic regulation. Active power automatic transducer); Electromecha-nical unit
control of synchronous generator working in parallel to infinite bus) (electromagnetic
Voltage and reactive power automatic control (Voltage automatic regulation by brake, induction motor, and angular
synchronous generator field changing. Voltage automatic regulation by static displacement transducer); Three-phase power
thyristor compensator reactive power changing) supply; Thyrister converter/regulator; Synchronous
Automatic control of electric power system mode (Automatic control of machine exciter; DC voltage source; Singlephase
autonomous single-machine electric power system mode. Automatic control of power supply; Turbine model power supply;
mode of singlemachine electric power system operating in parallel to infinite bus) Three-pole breaker; Terminal; Active load;
Emergency automation of electric power systems Automation of fault Model of transmission line; Line reactor; Series
clearing, reclosing and back-up (Automatic fault clearing on transmission line capacitive compensating device; Capacitive
with single supply. Automatic reclosing transmission line with single supply. load; Module of synchronizing; Inductive load;
Automatic reclosing transmission line with duplicate supply. Automatic switching- Connector; Module of digital signals
in step-down substation section switch) Automatic stability control (Automatic input/output; Module of diodes; Three-phase
control of dynamic stability by synchronous generator field forcing. Automatic transformer group; Module of current-andvoltage
control of dynamic stability by quick short-time synchronous generator prime mover transformers; Module of current-andvoltage
power reduction. Automatic control of dynamic staAutomatic asynchronous sensors; Voltage-and-frequency meter;
mode prevention (Automatic prevention of asynchronous mode caused by Synchronous machine torque angle meter;
transmission line overload. Automatic prevention of asynchronous mode caused by Speed indicator; Power meter; Laboratory
synchronous generator field loss) Automatic prevention of unacceptable tables; Accessories Kit; Basic Experiments
changes of regime parameters (Automatic voltage drop limitation by series Guide; Personal computer
capacitive compensation of transmission line. Automatic voltage rise limitation by
shunt reactor at transmission line end. Automatic frequency drop limitation by
electric power system load switching-off)

Page 150
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
5 Electric power engineering - Electric 1 Set Unit Prices Total Prices
power systems & networks Type / Model ( Rupiah ) ( Rupiah )
2.1. Power consumption, VA 500 EE1-ESS-S-R Please Contact Us
2.2. Electric supply:
- single-phase AC circuit P I C T U R E
with
working neutral and 220 22
protective leads 50 0,5
voltage, V
- frequency, Hz
2.3. Appliance class I
2.4. Total dimensions, mm
(assembled) 910
- length 850
- width 1600
- height
2.5. Weight, Kg 60

Module / Component Pcs


1 Single-phase Power Supply 1
2 Active Load 2
3 Transmission Line Model 3
4 Series Capacitive Compensating Device 1
5 Capacitive Load 1
6 Inductive Load 2
7 Power Meter Commutator 1
8 Automatic Single-pole Breaker 1
9 S ngle-phase Transformer 1
10 Multimeters Module (2 Multimeters) 1

Page 151
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
11 Single-phase Network Parameters Meter 2
12 Laboratory Table with 2-section Storage Container and 2-level Frame 1
13 Accessories Kit 1
14 Basic Experiments Guide 1
15 Operation Manual 1
16 Didactic Materials CD 1
BASIC EXPERIMENTS:

1. Modes of electroreceivers.
1.1. Finding static power-voltage characteristic of resistive load.
1.2. Finding static power-voltage characteristic of reactor..
1.3. Finding static power-voltage characteristic of resistive load.
1.4. Finding static power-voltage characteristic of capacitor bank.
2. Steady states of electric network elements.
2.1. Modeling single-phase transformer steady state.
2.2. Modeling electric transmission line phase steady state.
3. Electric network steady state.
3.1. Modeling electric single fed network (one phase) steady state.
3.2. Modeling electric double fed network (one phase) steady state.
4. Voltage regulation in electric network.
4.1. Counterload voltage control.
4.2. Voltage control by series reactive power compensation using capacitor bank.
4.3. Voltage control by shunt reactive power compensation using capacitor bank.

Page 152
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
6 Electric power engineering - Distribution apparatus of electric 1 Set Unit Prices Total Prices
power stations & substations Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 100 EE1-RU-S-R Please Contact Us
Electric supply:
- single-phase AC circuit with P I C T U R E
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1600
Weight, Kg 50

BASIC EXPERIMENTS
1. Electric circuits of switchgear.
1.1. Assembly of electric circuits of switchgear with single busbar.
1.1.1. Circuit of switchgear with single unsectioned busbar.
1.1.2. Circuit of switchgear with single sectioned busbar..
1.1.3. Circuit of switchgear with switchable and transfer busbars.
1.2. Assembly of electric circuits of switchgear with double busbars.
1.2.1. Circuit of switchgear with double busbars and bus-tie breaker.
1.2.2. Circuit of switchgear with double sectioned busbars, two bus-tie (Q1, Q2) and
two section (Q3, Q4) breakers.
1.2.3. Circuit of switchgear with double busbars and transfer busbar with bus-tie and
transfer breakers.
1.2.4. Circuit of switchgear with double busbars and transfer busbar with two bus-
tie and two transfer breakers.
1.3. Assembly of electric circuits of switchgear of ring type.
1.3.1. Circuit of switchgear Triangle.
1.3.2. Circuit of switchgear Quadrangle.

Page 153
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.3.3. Circuit of switchgear Hexagon.
1.3.4. Circuit of switchgear Transformer-switchgear with sesquialteral Module / Component Pcs
connecting. 1 Power Supply Module with Testing Board 1
1.3.5. Circuit of switchgear Sesquialteral" ( "three second"). 2 Testing Board 5
1.4. Assembly of simplified circuits of switchgear.
3 Mini-modules Set Distribution apparatus of electric power 1
1.4.1. Circuit of switchgear Line transformer unit.
1.4.2. Circuit of switchgear Bridge with breaker in connector (jumper) and stations & substations
isolating switches in transformer circuits. 4 Mini-modules Set Distribution apparatus of electric power 1
1.4.3. Circuit of switchgear Bridge with breaker in circuits of lines and maintenance stations & substations
isolated switch from side of lines. 5 Mini-modules Set Distribution apparatus of electric power 1
1.4.4. Circuit of switchgear Bridge with breakers in transformer circuits and maintenance stations & substations
isolated switch from side of transformers. 6 Mini-modules Set Distribution apparatus of electric power 1
1.4.5. Circuit of switchgear Entry - exit .
2. Operational commutations in switchgears. stations & substations
2.1. Switching when activating and deactivating of connections.. 7 Laboratory Table with 2-section Storage Container and 2-level 1
2.1.1. Enabling and disabling transmission line. Frame
2.2. Switching when transferring connections from one busbar to another. 8 Accessories Kit 1
2.2.1. Transfer of all connections from main busbar to backup via bus-tie breaker. 9 Basic Experiments Guide 1
2.2.2. Transfer of all connections from main busbar to backup when bus-tie breakers 10 Operation Manual 1
absent.
11 Didactic Materials CD 1
2.2.3. Transfer of all connections from one busbar to another via bus-tie breaker with fixed
connections distribution at busbars..
2.3. Switching-over at removal equipment out of service to maintenance and back to service
after maintenance.
2.3.1. Removal reserve busbar to maintenance at bus-tie breaker off and putting it into
service after maintenance.
2.4. Switching-over at removal breaker to maintenance and putting it into service after maintenance.
Removal bus-tie breaker to maintenance with change it by bypass breaker and putting it into service
after maintenance

Page 154
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
7 Energy saving in systems of electric 1 Set Unit Prices Total Prices
supply and consumption Type / Model ( Rupiah ) ( Rupiah )
ESSESP2-S-R Please Contact Us
P I C T U R E
Power consumption, VA 200
Electric supply:
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 2910
- width 850
- height 1600
Weight, Kg 100
BASIC EXPERIMENTS

1. Energy saving parameters.


1.1. Transformer efficiency.
1.2. Transmission line active power losses per unit
length.
1.3. Induction motor efficiency.
1.4. Filament lamp / compact low-pressure
luminescent lamp / photodiode lamp luminaire
efficiency.
1.5. Energy saving technical means in electric
supply systems.
1.6. Active power losses decrease in distribution
single-fed network by load reactive power
compensation.

Page 155
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.1. Active power losses decrease in distribution duplicate-fed network by voltage regulation. Module / Component Pcs
1.2. Active power losses decrease in distribution duplicate-fed network by cutting it. 1 Electromechanical Unit (DC Machine 101.1, Induction Motor 1
1.3. Obtaining high efficiency of low-loaded transformer by switching-off transformer connected 106 and Angular Displacement Transducer)
in parallel.
2 Frequency onverter 1
2. Energy saving technical means in electric consumption systems.
2.1. Obtaining high efficiency and power factor of low-loaded induction motor by switching its 3 Single-phase Power Supply 1
stator winding from Delta toStar. 4 Single-phase Power Supply 1
2.2. Decrease of induction motor power consumption by changing throttle to frequency 5 Active Load 3
regulation. 6 Transmission Line Model 2
2.3. Decrease of electric illumination per unit power consumption by changing filament lamp to 7 Capacitive Load 1
luminescent or photodiode lamp. 8 Adjustable Autotransformer 1
2.4. Decrease of power consumption in illumination system by zonal switching-off illumination.
9 Rectifier 1
2.5. Decrease of power consumption in illumination system by regulating intensity of
illumination. 10 Inductive Load 2
2.6. Decrease of power consumption in illumination system by illumination on/off with movement 11 Power Meter Commutator 1
sensor. 12 Automatic Single-pole Breaker 1
2.7. Decrease of power consumption in illumination system by illumination on/off with photo 13 Single-phase Transformer 2
relay. 14 One-button Switch 1
2.8. Decrease of power consumption in illumination system by illumination on/off with timer. 15 Toggle Switch 2
16 Electric Socket with Grounding Contact 1
17 Incandescent Lamp 1
26 Multimeters Module (2 Multimeters) 1 18 Dimmer 1
27 Photometer Module 1 19 Toggle Switch Y/ 1
28 Laboratory Table with 2-level Frame 1 20 One-button Switch 1
29 Laboratory Table with 2-section Storage Container and 2-level Frame 1 21 Movement Sensor Module 1
30 Accessories Kit 1 22 Light Photorelay Module 1
31 Basic Experiments Guide 1 23 Light Timer Module 1
32 Operation Manual 1 24 Speed Indicator 1
33 Didactic Materials CD 1 25 Power Meter 1
34 Luxmeter 1

Page 156
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
8 Quality of Electric energy in electric supply systems - single- 1 Set Unit Prices Total Prices
phase network Type / Model ( Rupiah ) ( Rupiah )
KEESESO1M-S-K Please Contact Us
2.1. Power consumption, VA 100 P I C T U R E
2.2. Electric supply:
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
2.3. Appliance class I
2.4. Total dimensions, mm (assembled)
- length 910
- width 850
- height 1600
2.5. Weight, Kg 50

BASIC EXPERIMENTS

1. Monitoring quality of electric energy in single-phase circuit.


1.1. Measuring parameters of electric energy quality in single-phase circuit 220 V.
1.2. Viewing and registering measured quality parameters of electrical energy using
personal computer.
2. Quality control of electric energy in single-phase circuit.
2.1. Counter voltage regulation.
2.2. Voltage regulation by shunt reactive power compensation using capacitor package.
2.3. Voltage regulation by series reactive power compensation using capacitor package.
2.4. Reducing current higher harmonics generation by replacing half-wave rectifier to full-
wave rectifier in DC load power supply.
2.5. Compensation of current higher harmonics using compensating filter.

Page 157
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT

Module / Component Pcs


1 Single-phase Power Supply 1
2 Active Load 1
3 Transmission Line Model 2
4 Series Capacitive Compensating Device 1
5 Capacitive Load 1
6 Adjustable Autotransformer 1
7 Rectifier 1
8 Inductive Load 1
Automatic Single-pole Breaker 1
10 Single-phase Transformer 1
11 Compensating Filter 1
12 Multimeters Module (2 Multimeters) 1
13 Electricity Quality Indicators Meter 1
14 Laboratory Table with 2-section Storage Container and 2-level Frame 1
15 Accessories Kit 1
16 Basic Experiments Guide 1
17 Operation Manual 1
18 Notebook 1
19 USB/RS-232 Interface Converter 1

Page 158
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
9 Quality of electric energy in electric supply systems - 1 Set Unit Prices Total Prices
Three-phase network Type / Model ( Rupiah ) ( Rupiah )
KEESEST1M-S-K Please Contact Us
2.1. Power consumption, VA 1000 P I C T U R E
2.2. Electric supply:
- three-phase AC circuit with
working neutral and protective leads
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
2.3. Appliance class I
2.4. Total dimensions, mm (assembled)
- length 2910
- width 850
- height 1900
2.5. Weight, Kg 200

BASIC EXPERIMENTS:

1. Monitoring quality of electrical energy in three-phase circuit.


1.1. Measuring parameters of electric energy quality in three-phase circuit.
1.2. Viewing and registering measured quality parameters of electrical energy using
personal computer.
2. Control of electric energy quality in three-phase circuit.
2.1. Counter voltage regulation.
2.2. Voltage regulation by shunt reactive power compensation using capacitor package.
2.3. Voltage regulation by series reactive power compensation using capacitor package.
2.4. Reducing current higher harmonics generation by replacing three-pulsed rectifier to
six-pulsed rectifier in DC load power supply.
2.5. Compensation of current higher harmonics using compensating filter.
Page 159
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Three-phase Power Supply 1
2 Single-phase Power Supply 1
3 Active Load 1
4 Transmission Line Model 2
5 Series Capacitive Compensating Device 1
6 Capacitive Load 1
7 Inductive Load 1
8 Diodes Module 1
9 Three-phase Transformer Group 2
10 Power Meter Commutator 1
11 Compensating Filter 3
12 Current Transformer 3
13 Voltage Transformer 3
14 Electricity Quality Indicators Meter 1
15 Laboratory Table with 2-section Storage Container and 3-level Frame 1
16 Laboratory Table 1
17 Accessories Kit 1
18 Basic Experiments Guide 1
19 Operation Manual 1
20 Notebook 1
21 USB/RS-232 Interface Converter 1

Page 160
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
10 Detecting cable line damage 1 Set Unit Prices Total Prices
Power consumption, VA 50 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
- single-phase AC circuit with OPKL1-N-R Please Contact Us
working neutral and protective leads P I C T U R E
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 625
- width 350
- height 400
Weight, Kg 10
Module / Component Pcs
1 Single-phase Power Supply 1
2 Electric Cable Transmission Line Model 1
3 Single-level Desktop Frame with Container (length 625 mm) 1
4 Accessories Kit 1
5 Basic Experiments Guide 1
6 Operation Manual 1
7 Didactic Materials CD 1
8 Reflectometer 1
9 Portable Cable Bridge PKM-105 or analog 1
BASIC EXPERIMENTS
1.Detecting cable line damage with cable fault-locating equipment (cable bridgePKM-
105). Type of cable line damage.
1.1. Distance to cable line damage place.
1.2. Distance to place of loss of cable.
2. Detecting cable damage with pulse reflectometer REYS-100.
2.1.Type of cable line damage.
2.2.Distance to cable line damage place.

Page 161
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
11 Electric distributional grid with mode optimization 1 Set Unit Prices Total Prices
2.1. Power consumption, VA 200 Type / Model ( Rupiah ) ( Rupiah )
2.2. Electric supply:
- single-phase AC circuit with RESOR1-S-K Please Contact Us
working neutral and protective leads P I C T U R E
voltage, V 220 22
- frequency, Hz 50 0,5
2.3. Appliance class I
2.4. Total dimensions, mm (assembled)
- length 910
- width 850
- height 1900
2.5. Weight, Kg 110

BASIC EXPERIMENTS

1.1. Steady states of distribution system elements.


1.1. Modeling steady state of single-phase transformer.
1.2. Modeling steady state of a phase of transmission line. .
1.3. Finding power voltage characteristics of dead load.
1.2. Steady states of distribution systems.
2.1. Modeling steady state of single-fed distribution network (1 phase).
2.2. Modeling steady state of duplicate-fed distribution network (1 phase)..
1.3. Voltage regulating in distribution systems.
3.1. Counter voltage regulation.
3.2. Voltage regulation by shunt reactive power compensation using capacitor
package.
1.4. Optimization of local distribution network mode.
4.1. . Determination of active power losses in local distribution network,
constructed as loop circuit.

Page 162
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
4.1. Estimation of influence of supply center bus voltages difference on Module / Component Pcs
power losses in local distribution network, constructed as loop circuit, 1 Single-phase Power Supply 1
when operating in closed mode. 2 Single-phase Power Supply 1
4.2. Estimation of influence of cutting place on power losses in local
3 Transmission Line Model 5
distribution network, constructed as loop circuit.
4.3. Finding normal (optimal) cutting place in local distribution network, 4 Capacitive Load 2
constructed as loop circuit, according to criterion of minimum active 5 Power Meter Commutator 1
power losses. 6 Single-phase Transformer 2
4.4. Operation of local distribution network, constructed as loop circuit, in 7 Transformer Substation and Load Model 4
mode of automatic selection of normal cutting place according to 8 Single-phase Network Parameters Meter 2
criterion of minimum active power losses. 9 Laboratory Table 1
4.4. Optimization of regional distribution network mode.
10 Accessories Kit 1
5.1. Measurement and determination of mode parameters of closed (ring)
regional distribution network. 11 Basic Experiments Guide 1
5.2. Determination of compensation capacitors optimal power in closed 12 Operation Manual 1
(ring) regional distribution network according to criterion of minimum 13 Didactic Materials CD 1
active power losse 14 Uninterrupted Power Supply Unit 1

Page 163
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
12 Protection & Automation in electric supply systems 1 Set Unit Prices Total Prices
(based on programmable controller) Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 50 RZASESK1-S-K Please Contact Us
Electric supply:
- single-phase AC circuit with P I C T U R E
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 920
- width 350
- height 800
Weight, Kg 20
Module / Component Pcs
1 Single-phase Power Supply 1
2 Transmission Line Model 2
3 Push-button Control Module 1
4 Light Signaling Module 1
5 Contactor 2
6 Single-phase Transformer 1
7 Programmable Controller Module 1
8 Current-and-voltage Transformers Module 1
9 Voltage Converters Module 1
10 Current and Time Measurer 1
11 Laboratory Table 1
12 Laboratory Table with 2-section Storage Container and 2-level Frame 1
13 Accessories Kit 1
14 Basic Experiments Guide 1
15 Operation Manual 1

Page 164
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT

BASIC EXPERIMENTS
1. Relay protection.
1.1. Modeling transmission line overcurrent protection.
1.2. Modeling transmission line instantaneous current cutoff.
1.3. Modeling radial single-fed network overcurrent protection.
1.4. Modeling transmission line differential protection.
1.5. Modeling transformer differential protection.
2. Automation.
2.1. Automatic switching load supply back-up.
2.2. Automatic reclosing transmission line

Page 165
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
RENEWABLE ENERGY G A L S E N
No Name of Equipment Quantity
1 Wind Power Generator Model 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Synchronous generator with permanent magnet (Finding no-load characteristic E=f(n).
Finding external characteristics U=f(I), =f(I). Finding speed characteristics U=f(n), I=f(n) NEE2-VEG-N-R Please Contact Us
=f(n) at constant load resistance) P I C T U R E
Wind-electrical synchronous generator (Finding dependences of generator power and wind
turbine rotational moment from speed =f(n) and =f(n) at constant wind speed. Finding
dependence of turbine speed from wind speed n=f(v) at constant generator load. Finding
dependence of generator power from wind speed =f(v) at constant turbine speed. Finding
dependence of turbine speed from wind speed n=f(v) at max value of generator power. Finding
dependence of max value of generator power from blade s number of wind turbine =f(m)

Modules / Components:*
Load & Measurement Module
Tachometer Stand
Accessories Kit
Basic Experiments Guide
Tachometer
Wind-turbine Generator
Anemometer
Fan

Page 166
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 Wind Power Plant Model 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Checking the wind turbine integrity. Readout of voltage, current, power and speed of wind
turbines depending on the wind speed. Simulation of autonomous mode of wind power plant. NEE3-VEU-S-K Please Contact Us
Determination of amount of electrical energy produced during the experiment (which can be P I C T U R E
generated for a month, or a year) of a wind power plant with a priori defined mean wind speed
and the shape parameter of the distribution function of wind speed.

Modules / Components:
Wind Power Generator Module
Single-phase Power Supply
Rechargeable Battery Module
Electrical Load
Wind Power Generator Terminal
Laboratory Table
Accessories Kit
Basic Experiments Guide
Notebook

Page 167
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
3 PV Solar Power Plant Model 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
PV module characteristics (Currentvoltage characteristic. Power-voltage characteristic.
Short-circuit current VS irradiance. Short-circuit current VS light rays slope angle on PV NEE3-MFESE-N-R Please Contact Us
module surface. Short-circuit current VS PV module temperature. No-load voltage VS PV P I C T U R E
module temperature. Maximum power VS PV module temperature)
Model of autonomous PV Solar Power Plant (Accumulator battery chargedischarge
controller operating characteristics. Modeling autonomous PV Solar Power Plant modes of
operation)

Modules / Components:
Power Supply
Charge-discharge Controller
Photovoltaic Module
Load and Measurement Module
Light Source
Module Of Two Multimeters
Desktop Container With 2-Level Frame
Accessories Kit
Basic Experiments Guide

Page 168
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
4 Heat Pump 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Basic Experiments: NVIE1-TN-S-K Please Contact Us
Heat pump operating parameters (coolant temperature and pressure in different points,
electrical energy consumed, output thermal energy, conversion factor) Heat pump conversion P I C T U R E
factor VS medium temperature of low-level heat source Heat pump conversion factor VS
medium temperature of high-level heat source Heat pump productivity control Measurement,
determination and display of heat pump operating parameters by
computer

Modules / Components:
Water Source Model (Water Tank, Stand)
Heat Pump Module
Accessories Kit
Basic Experiments Guide
Notebook With Software

Page 169
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
5 Speed sensors 1 Set Unit Prices Total Prices
2.1. Power consumption, VA 50 Type / Model ( Rupiah ) ( Rupiah )
2.2. Electric supply:
- single-phase AC circuit with DSVR1-N-R Please Contact Us
working neutral and protective leads P I C T U R E
voltage, V 220 22
- frequency, Hz 50 0,5
2.3. Appliance class I
2.4. Total dimensions, mm (assembled)
- length 625
- width 500
- height 400
2.5. Weight, Kg 10
Module / Component Pcs
1 Single-phase Power Supply 1
2 DC Voltage Source 1
3 Speed Sensors Module 1
4 Pulse Counter Module 1
5 Multimeters Module (2 Multimeters) 1
6 Single-level Desktop Frame with Container (length 910 mm) 1
7 Accessories Kit
8 Basic Experiments Guide 1
9 Operation Manual 1
BASIC EXPERIMENTS:

4.4. Setting up digital speed sensor (optical encoder).


4.5. Finding dependence of DC tachometer output voltage of rotation speed and determining
slope of its output characteristic.

Page 170
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
6 Alternative power generation - Photovoltaic module 1 Set Unit Prices Total Prices
2.1. Power consumption, VA 200 Type / Model ( Rupiah ) ( Rupiah )
2.2. Electric supply: NEE2-FEM-S-R Please Contact Us
- single-phase AC circuit with P I C T U R E
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
2.3. Appliance class I
2.4. Total dimensions, mm (assembled)
- length 910
- width 850
- height 1600
2.5. Weight, Kg 75
BASIC EXPERIMENTS

1. Photovoltaic module volt-ampere characteristic U=f(I).


2. Photovoltaic module energy characteristic P=f(U).
3. Photovoltaic module short-circuit current VS energy illumination I =f().
4. Photovoltaic module short-circuit current VS light inclination angle ISC=f().
5. Photovoltaic module short-circuit current VS module temperature ISC =f().
6. Photovoltaic module no-load voltage VS its temperature Uno-load =f().
7. Photovoltaic module maximum power VS its temperature M=f().

Page 171
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Power Supply Module 1
2 Phot electric Module 1
3 Load & Measurement Module 1
4 Light Source 1
5 Multimeters Module (2 Multimeters) 1
6 Laboratory Table 1
7 Accessories Kit 1
8 Basic Experiments Guide 1
9 Operation Manual 1
10 Didactic Materials CD 1

Page 172
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
7 Rotating transforme 1 Set Unit Prices Total Prices
Power consumption, VA 50 Type / Model ( Rupiah ) ( Rupiah )
Power supply:
- single-phase AC mains with VT1-N-R Please Contact Us
working neutral and protective wires P I C T U R E
- voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 625
- width 500
- height 400
Weight, kg 10
Name Pcs
1 Single-phase power supply 1
2 Module of rotating transformer 1
3 Module of 2 multimeter 1
4 Desktop container with 1-level frame (length 625 mm) 1
5 Accessories Kit 1
6 Basic Experiments Guide Rotating transformer 1
7 Operating Manual 1

Page 173
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS

1. Operation of sine-cosine rotating transformer in sine mode.


1.1 Sine winding output voltage VS angle of rotor rotation.
1.2 Sine winding output voltage VS angle of rotor rotation taken by method of primary balancing.
1.3 Rotating transformer operating parameters (sine winding output voltage, implementation error of sine function, transformation ratio, electromotive force of compensating winding,
residual EMF in zero points).
2. Operation of sine-cosine rotating transformer in sine-cosine mode.
2.1 Sine and cosine windings output voltages VS angle of rotor rotation at no-load.
2.2 Sine and cosine windings output voltages VS angle of rotor rotation at load (method of primary balancing).
2.3 Rotating transformer operating parameters (sine and cosine windings output voltages, implementation error of sine and cosine functions, transformation ratios of sine and cosine
windings, difference between sin and cosine windings transformation ratios, electromotive force of compensating winding, residual EMF in zero points).
3. Operation of sine-cosine rotating transformer in linear mode.
3.1 Output voltage VS angle of rotor rotation.;
3.2 Rotating transformer operating parameters (estimated value of output voltage, implementation error of linear function).

Page 174
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
ELECTRIC SAFETY G A L S E N
No Name of Equipment Quantity
1 Electric safety in three-phase networks with isolated 1 Set Unit Prices Total Prices
and earthed neutrals Type / Model ( Rupiah ) ( Rupiah )
2.1. Power consumption, VA 150 EBTS1-S-R Please Contact Us
2.2. Electric supply:
- three-phase AC circuit with P I C T U R E
working neutral and protective leads
voltage, V 380 38
- frequency, Hz 50 0,5
2.3. Appliance class I
2.4. Total dimensions, mm (assembled)
- length 910
- width 300
- height 800
2.5. Weight, Kg 25

BASIC EXPERIMENTS

1. Electric safety in three-phase networks with isolated neutral.


1.1. Finding dependence of current through human body when its in direct touch to parts
under voltage, of network insulation resistance at the absence of ground fault.
1.2. Finding dependence of current through human body when its in direct touch to parts
under voltage, of network phase capacitance at the absence of ground fault.
1.3. Finding dependence of current through human body when its in direct touch to parts
under voltage, of shoes resistance at the absence of ground fault.
1.4. Finding dependence of current through human body when its in direct touch to parts
under voltage, of floor resistance at the absence of ground fault.

Page 175
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.1. Finding dependence of current through human body when its in direct touch to parts under voltage, of network insulation resistance during ground fault.
1.2. Finding dependence of current through human body when its in direct touch to parts under voltage, of network phase capacitance during ground fault.
1.3. Finding dependence of current through human body when its in direct touch to parts under voltage, of ground fault resistance.
1.4. Finding dependence of contact voltage of ground fault resistance.
1.5. Finding dependence of contact voltage of floor resistance.
1.6. Finding dependence of network phase voltage of ground fault resistance.
2. Electric safety in three-phase networks with earthed neutral.
2.1. Finding dependence of current through human body when its in direct touch to parts under voltage, of network insulation resistance at the absence of ground fault.
2.2. Finding dependence of current through human body when its in direct touch to parts under voltage, of network phase capacitance at the absence of ground fault.
2.3. Finding dependence of current through human body when its in direct touch to parts under voltage, of shoes resistance at the absence of ground fault.
2.4. Finding dependence of current through human body when its in direct touch to parts under voltage, of floor resistance at the absence of ground fault.
2.5. Finding dependence of current through human body when its in direct touch to parts under voltage, of network insulation resistance during ground fault.
2.6. Finding dependence of current through human body when its in direct touch to parts under voltage, of network phase capacitance during ground fault.
2.7. Finding dependence of current through human body when its in direct touch to parts under voltage, of ground fault resistance.
Finding dependence of network phase voltage of ground fault resistance

Module / Component Pcs


1 Three-phase Power Supply 1
2 Three phase Transformer 1
3 Electric Circuit Segment Model 1
4 Human Body Model 1
5 Model of ground fault 1
6 Linear Choke Model 1
7 Multimeters Module (3 Multimeters) 1
8 Two-level Desktop Frame with Container 1
9 Accessories Kit 1
10 Basic Experiments Guide 1
11 Operation Manual 1
12 Didactic Materials CD 1

Page 176
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 Electric safety in three-phase networks with isolated and earthed 1 Set Unit Prices Total Prices
neutrals Type / Model ( Rupiah ) ( Rupiah )
2.1. Power consumption, VA 150 EBTS2-S-R Please Contact Us
2.2. Electric supply:
- three-phase AC circuit with P I C T U R E
working neutral and protective leads
voltage, V 380 38
- frequency, Hz 50 0,5
2.3. Appliance class I
2.4. Total dimensions, mm (assembled)
- length 910
- width 850
- height 1600
2.5. Weight, Kg 45

BASIC EXPERIMENTS

2. Electric safety in three-phase networks with isolated neutral.


2.1. Finding dependence of current through human body when its in direct touch to parts
under voltage, of network insulation resistance at the absence of ground fault.
2.2. Finding dependence of current through human body when its in direct touch to parts
under voltage, of network phase capacitance at the absence of ground fault.
2.3. Finding dependence of current through human body when its in direct touch to parts
under voltage, of shoes resistance at the absence of ground fault.
2.4. Finding dependence of current through human body when its in direct touch to parts
under voltage, of floor resistance at the absence of ground fault.
2.5. Finding dependence of current through human body when its in direct touch to parts
under voltage, of network insulation resistance during ground fault.
2.6. Finding dependence of current through human body when its in direct touch to parts
under voltage, of network phase capacitance during ground fault.
2.7. Finding dependence of current through human body when its in direct touch to parts
under voltage, of ground fault resistance.

Page 177
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.1. Finding dependence of contact voltage of ground fault resistance.
1.2. Finding dependence of contact voltage of floor resistance.
1.3. Finding dependence of network phase voltage of ground fault resistance.
1.4. Evaluation of RCCB efficiency.
2. Electric safety in three-phase networks with earthed neutral.
2.1. Finding dependence of current through human body when its in direct touch to parts under voltage, of network insulation resistance at the absence of ground fault.
2.2. Finding dependence of current through human body when its in direct touch to parts under voltage, of network phase capacitance at the absence of ground fault.
2.3. Finding dependence of current through human body when its in direct touch to parts under voltage, of shoes resistance at the absence of ground fault.
2.4. Finding dependence of current through human body when its in direct touch to parts under voltage, of floor resistance at the absence of ground fault.
2.5. Finding dependence of current through human body when its in direct touch to parts under voltage, of network insulation resistance during ground fault.
2.6. Finding dependence of current through human body when its in direct touch to parts under voltage, of network phase capacitance during ground fault.
2.7. Finding dependence of current through human body when its in direct touch to parts under voltage, of ground fault resistance.
2.8. Finding dependence of network phase voltage of ground fault resistance.
2.9. Evaluation of RCCB efficiency.

Module / Component Pcs


1 Three-phase Power Supply 1
2 Three phase Transformer 1
3 Electric Circuit Segment Model 1
4 Human Body Model 1
5 Model of ground fault 1
6 Residual Current Device 1
7 Linear Choke Model 1
8 Multimeters Module (3 Multimeters) 1
9 Laboratory Table with 2-section Storage Container and 2-level Frame 1
10 Accessories Kit 1
11 Basic Experiments Guide 1
12 Operation Manual 1
13 Didactic Materials CD 1

Page 178
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
3 Electric safety in domestic and office buildings 1 Set Unit Prices Total Prices
Power consumption, VA 50 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
- single-phase AC circuit with EBZP2-S-R Please Contact Us
working neutral and protective leads P I C T U R E
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1600
Weight, Kg 35

BASIC EXPERIMENTS:
2.0. 1. Effect of electric current on human being in residential and office buildings.
2.1. Determination of electric current through human body at direct touch to parts under
voltage.
2.2. Determination of electric current through human body at indirect touch to parts under
voltage.
3. Measures to protect human being against electric shock in residential and
office buildings.
3.0. Operation of protective neutral grounding.
3.1. Protective effect of automatic power-off when overcurrent.
3.2. Protective effect of appliance double insulation.
3.3. Operation of protective switching device (RCCB).
4. Comprehensive protection of human being against electric shock in residential
and office buildings.
4.0. Protection operating at direct human touch to parts under voltage.
4.1. Protection operating at damage of appliance system insulation, class 0.
4.2. Protection operating at damage of appliance system insulation, class I.
4.3. Protection operating at damage of appliance system insulation, class II.
4.4. Protection operating at mistaken joining neutral, system and protective, conductors.
Protection operating at breakage of neutral protective conductor.
Page 179
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Single-phase Power Supply 1
2 Human Body Model 1
3 Residual Current Device 1
4 Automatic Single-pole Breaker 1
5 Electric Supply Grid Model 1
6 Model of electro receiver with working insulation 1
7 Model of electro receiver with double insulation 1
8 Multimeters Module (2 Multimeters) 1
9 Laboratory Table with storage container and single-level frame 1
10 Accessories Kit 1
11 Basic Experiments Guide 1
12 Operation Manual 1
13 Didactic Materials CD 1

Page 180
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
4 Electric Safety Fundamentals 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Factors determining conditions of electrical safety (Study of shoes and floor resistance
influence on the electric safety conditions; Study of neutral mode influence on electric safety OEB1-S-R Please Contact Us
conditions; Study of electric network parameters (insulation resistance and capacity P I C T U R E
admittance) influence on the electric safety conditions; Study of the ground fault resistance
influence on electric safety conditions in network with isolated neutral) Phenomena of leaking
current into ground through protective earthing electrode Electrical resistance of
human body Simulation of protective neutral earthing of electrical equipment Isolation
control in electric network with isolated neutral (Isolation control using method of 3
voltmeters; Isolation control by means of specialized device) Measurement of grounding
resistance by ampermeter and voltmeter for 4 different types of earth Simulation of
protective grounding / autogrounding of electrical equipment (Performance of cutout
device in electric network; Performance of cutout device in electric network with dead
grounded neutral; Performance of cutout device in electric network with isolated neutral)
Modules / Components:
Three-phase Power Supply; Single-phase
Power Supply; Three-phase Transformer;
Electric Network Section Model; Human
Being Simulator; Ground Fault Model;
Insulation Resistance Simulator; Model of
Grounding Measurements Insulation
Monitor; Protective Switching Device;
Ground w/Hemispherical Electrode
Simulator; Ground w/Vertical Tubular
Electrode Simulator; Ground w/Long
Tubular Electrode on Surface Simulator;
Model of Protective Grounding /
Autogrounding; Model of Neutral
Grounding; Line Chokes Unit; Resistance of
Human Body Study Device; Three
Multimeters Unit; Laboratory Tables;
Accessories Kit; Basic Experiments Guide

Page 181
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
5 Electric Safety in Installations up to 1000V 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Effect of electric current on human being (Determination of electric current through human
body at direct touch to parts under voltage. Determination of electric current through human EBEU2-N-R Please Contact Us
body at indirect touch to parts under voltage. Determination of human body resistance) P I C T U R E
Measures to protect human being from electric shock (Action of protective neutral
grounding. Protective effect of automatic power-off when overcurrent. Protective effect of
appliance double insulation. Operation of protective switching device. Operation of protective
grounding. Protective effect of neutral protective conductor re-grounding. Protective effect of
lower voltage. Protective effect of electric circuits separation. Phase insulation monitoring in
grid with insulated neutral) Protection from electric shock in installations with grounding
TN-C and grounded installations bodies (Confirmation of inappropriate use of protective
switching devices. Confirmation of protection absence at direct human body touch to parts
under voltage. Protection operating at damage of appliance system insulation, class I)
Protection from electric shock in installations with grounding TN-C and
groundinsulated installations bodies (Protection operating at direct human touch to parts
under voltage. Protection operating at damage of appliance system insulation, class I)
Protection from electric shock in installations with grounding TN-S (Protection operating
at direct human touch to parts under voltage. Protection operating at damage of appliance
system insulation, class I. Protection operating at mistaken joining neutral, system and
protective, conductors. Protection operating at breakage of neutral protective conductor)
Protection from electric shock in installations with grounding TN-C-S (Protection
operating at direct human touch to parts under voltage. Protection operating at damage of
appliance system insulation, class I. Protection operating at wrong joining neutral, system and
protective, conductors. Protection operating at breakage of neutral protective conductor)
Protection from electric shock in installations with grounding TT (Protection operating
at direct human touch to parts under voltage. Protection operating at damage of appliance
system insulation, class 01) Protection from electric shock in installations with grounding
TI (Protection operating at direct human touch to parts under voltage. Protection operating at
damage of appliance system insulation, class 0. Protection operating at damage of appliance
system insulation, class II) Protection from electric shock in installations with grounding
IT (Confirmation of inappropriate use of protective switching devices. Grid insulation
monitoring. Protection operating at damage of appliance system insulation, class 0)

Page 182
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Modules / Components:
Single-phase Power Supply; Model Of Grid
Section; Human Being Simulator;
Protective Switching Device; Device For
Human Body Resistance Test; Automatic
Single-pole Breaker; Model Of Supply Grid;
Model Of Appliance With Working Insulation;
Model Of Appliance With Double
Insulation; Reducing Transformer; Model
Of Grounding; Insulating Transformer;
Module Of Two Multimeters; Desktop
Container With 2-level Frame; Accessories

Page 183
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
ENERGY SAVING G A L S E N
No Name of Equipment Quantity
1 Energy Saving in Electric Lighting Systems 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
ESSEO2-S-R Please Contact Us
Basic Experiments:
Energy efficiency of light sources (Comparison of light efficiency of halogen lamps,
compact fluorescent lamps of low pressure, and LED lamps with incandescent lamps;
Comparison of light efficiency of fluorescent lamps, highpressure mercury-vapor and
incandescent lamps; Comparison of light efficiency linear fluorescent lamps of low pressure
from the starter and electronic control gear)
Devices for energy savings in electric lighting systems (Reactive power compensation
by means of capacitor in case of linear fluorescent low-pressure lamp with starter;
Diminishing power consumption by means of electric lighting zonal off; Diminishing power
consumption by means of light intensity regulation; Diminishing power consumption by
means of on/off lighting by motion sensor; Diminishing power consumption by means of
on/off lighting by photo relay; Diminishing power consumption by means of on/off lighting by
timer)
Modules / Component
Single-phase Power Supply ; Adjustable Autotransformer; Rocker Switch; Switch Plug with
Earthing Contacts ; Dimmer ; Fluorescent Lamp Unit ; Mercury-Vapor Lamp Choke ;
Rocker Switch (non-fixing) ; Motion Sensor Unit ; Photocell Lighting Unit ; Lighting Timer
Unit ; Voltmeter ; Photometric Unit ; Single-phase Network Parameters Meter ; Laboratory
Table with 3-Level Frame ; Illuminometer ; Acessories Kit ; Basic Experiments Guide

Page 184
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 Energy Saving in Power Supply Systems 1 Set Unit Prices Total Prices
and Electricity Consumption Systems Type / Model ( Rupiah ) ( Rupiah )
ESSESP2-S-R Please Contact Us
P I C T U R E
Basic Experiments:
Modules / Components: Energy Saving Indicators (Transformer efficiency. The
Electromechanical Unit (DC Machine, specific active power losses in transmission line. Induction
; Induction Motor And Angle-to-digit ; motor efficiency. Light output of incandescent lamp (low
Converter); Frequency Converter; pressure compact fluorescent lamp, LED lamp).
Singlephase ; Power Supply; Active Technical means of energy saving in electric power
Load; Transmission Line Model; systems (Reduction of active power losses in distribution
Capacitive Load; Adjustable network with unilateral supply by compensating load
Autotransformer; Rectifier; Inductive reactive power. Reduction of active power losses in
Load; Power Meter Commutator; distribution network with dual supply by voltage control.
Automatic Single-pole Switch; Reduction of active power losses in distribution network
Singlephase Transformer; One-button with dual supply by implementing cut therein. Ensuring
Switch Switch; Electric Socket With high efficiency of low loaded transformer by switching off
Grounding Contacts; Incandescent parallel working transformer) Technical means of energy
Lamp; Dimmer Switch Y/A; One- saving in electricity consumption systems (Ensuring
button Switch Without Fixing; Motion high efficiency and power factor of low loaded induction
Sensor Module; Lighting Photorelay motor by switching stator winding from "delta" to "star".
Module; Lighting Timer Module Speed Reducing electric power consumed by induction motor of
Indicator; Power Meter; Two- pump or ventilation system by replacing fluid flow throttle
Multimeters Module; Photometric control by frequency speed control. Reducing specific
Module; Two-level Frame With energy consumption of electric lighting system by replacing
Container; Luxmeter; Accessories Kit; incandescent lamp by fluorescent or LED lamps. Reducing
Basic Experiments Guide lighting power consumption by zonal lighting switching off.
Reducing lighting power consumption by light intensity
regulating. Reducing lighting power consumption by light
on / off with motion sensor. Reducing lighting power
consumption by light on / off with photorelay. Reducing
lighting power consumption by light on / off with timer)

Page 185
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
ELEMENTS OF AUTOMATION G A L S E N
No Name of Equipment Quantity
1 Actuating DC Motor 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Actuating DC motor with armature control (Readout of mechanical characteristics; Readout
of control characteristic; Determining characteristics of the mechanical power) IDPT1-N-R Please Contact Us
Actuating DC motor with pulse control (Readout of mechanical characteristics; Readout of P I C T U R E
control characteristic; Determining characteristics of the mechanical power

Modules / Components:
Single-phase Power Supply
Actuating DC Motor Unit
Two Multimeters Unit
Desktop Containter with 1-Level Frame
Accessories Kit
Basic Experiments Guide

Page 186
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 Informational Electric Machines 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Operation of sine-cosine rotary transformer in sine mode Operation of sine-cosine rotary
transformer in sine-cosine mode Operation of sine-cosine rotary transformer in linear mode IEM1-N-R Please Contact Us
Operation of selsyns in indicator mode Operation of selsyns in transformer mode Adjusting P I C T U R E
digital speed sensor (optical encoder) Readout of curve of DC tachogenerator output voltage
vs speed and determination of slope of its output characteristics

Modules / Components:
Single-phase Power Supply
DC voltage Power Supply
Selsyns Unit
Rotary Transformers Unit
Speed Sensors Unit
Pulse Counter Unit
Two Multimeters Unit
Desktop Containter with 1-Level Frame
Accessories Kit
Basic Experiments Guide

Page 187
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
3 Actuating Hysteresis Motor 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Basic Experiments:
External characteristics of hysteresis Motor Operating characteristics of hysteresis motor IGD1-N-R Please Contact Us
P I C T U R E
Modules / Components:
Single-phase Power Supply
Adjustable Autotransformer
Module Of Actuating Hysteresis Motor
Module Of 2 Multimeter
Desktop Container With 1-level Frame
Accessories Kit
Basic Experiments Guide

Page 188
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
4 Actuating Brushless DC Motor 1 Set Unit Prices Total Prices
Basic Experiments Type / Model ( Rupiah ) ( Rupiah )
Operating parameters of actuating brushless DC motor with Hall sensors External IBDPT1-N-K Please Contact Us
characteristic of actuating brushless DC motor with Hall sensors. Regulating characteristic of P I C T U R E
actuating brushless DC motor with Hall sensors Determination of switching sequence of
brushless DC motor switches Operating parameters of actuating brushless DC motor without
Hall sensors External characteristic of actuating brushless DC motor without Hall sensors

Modules / Components:
Single-phase Power Supply
Module Of Actuating Brushless Dc Motor
Desktop Container With 1-level Frame
Accessories Kit
Basic Experiments Guide
USB Oscilloscope
Notebook With Software

Page 189
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
ELECTRIC INSTALLATION WORK G A L S E N
No Name of Equipment Quantity
1 Altivar Frequency Converter Adjustment 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Introduction to frequency converter (Programming frequency converter. Switching on
frequency converter and setting factory default values. Preparing frequency converter to work) NPCH1-S-R Please Contact Us
Adjustment of an open system of electric drive "Frequency converter induction P I C T U R E
motor" (Determining electric drive coordinates static dependencies from induction motor shaft
torque. Determining electric drive coordinates static dependencies from converter control
voltage. Plotting electric drive power diagram)
Adjustment of electric drive "Frequency converter - induction motor" in compensation
mode (Determining electric drive coordinates static dependencies from induction motor shaft
torque in slip compensation mode. Determining electric drive coordinates static dependencies
from induction motor shaft torque in IRcompensation mode. Plotting electric drive power
diagrams at different compensation
mode)
Reproducing braking methods in electric drive "Frequency converter induction
motor" (Braking with timed ramp. Rapid breaking. Braking a freewheel. Dynamic breaking)
Adjustment of an open system of electric drive "Frequency converter induction
motor" in energy saving mode (Determining electric drive coordinates static dependencies
from induction motor shaft torque in energy saving mode. Plotting electric drive power diagram
in energy saving mode)
Adjustment of a closed system of electric drive "Frequency converter - induction
motor" (Preparing frequency converter. Setting speed loop proportional controller.
Determining electric drive coordinates static dependencies from induction motor shaft torque
since using proportionalplus- integral controller. Plotting closed type electric drive power
diagram)

Modules / Components:
Electromechanical Unit with Flywheel (DC;Machine, AC Machine and Angle-to-Digit;Converter)
DC Voltage Power Supply;Frequency Converter;Single-phase Power Supply;Speed Indicator
Laboratory Table;Basic Experiments Guide;Accessories Kit;Two-Channel Oscilloscope

Page 190
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 Magnetic Starter Wiring and Adjustment 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
Assembling and checking induction motor control circuit providing its direct start (non-reversing
magnetic starter circuit) Assembling and checking induction motor control circuit providing its EMNMP1-N-R Please Contact Us
direct start and reverse (reversing magnetic starter circuit) Adjusting and checking induction P I C T U R E
motor thermal protection based on electrothermal relay (non-reversing magnetic starter circuit
with electrothermal relay Assembling and checking induction motor overcurrent protection
based on automatic switch

Modules / Components:
Induction Motor
Three-phase Power Supply
Push-button Control Station
Light Signaling Module
Electrothermal Relay
Automatic Single-pole Switch
Automatic Three-pole Switch
Terminal Board
Contactor
Voltmeter
Ammeter
Desktop Container with 2-Level Frame
Basic Experiments Guide
Accessories Kit

Page 191
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
3 Open & Buried Wiring Technology 1 Set Unit Prices Total Prices
Basic Experiments: Type / Model ( Rupiah ) ( Rupiah )
TOSEM1-S Please Contact Us
Technology of open wiring (Open wiring of group electric two-wire lighting and sockets
network. Open wiring of group electric two-wire lighting and sockets network with TN-C-S type P I C T U R E
of grounding)
Technology of buried wiring (Buried wiring in solid wall of group two-wire electric lighting
and sockets network. Buried wiring in solid wall of group two-wire electric lighting and sockets
network with TN-C-S grounding. Buried wiring in hollow wall of group two-wire electric lighting
and sockets network. Buried wiring in hollow wall of group two-wire electric lighting and
sockets network with TN-C-S type of grounding)

Modules / Components:
Single-phase Power Supply
Wiring Panel (Board)
Imitator of Hollow Wall
Imitator of Solid Wall
Laboratory Table
Accessories Kit
Basic Experiments Guide
Multimeter
Optional Open and Buried Wiring
Components Set (wires, sockets,
switches, lamps, etc)

Page 192
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
RADIO ENGINEERING G A L S E N
No Name of Equipment Quantity
1 Radio Circuits & Signals 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
RTCS2-S-K Please Contact Us
Ordering Information
Basic Experiments:
Linear circuits of first order Linear circuits of second order Frequency characteristics of
linear circuits Nonlinear circuits Transistor resistive amplifier Amplifier with feedback
Generators of oscillators Study of oscillator with Wien bridge Amplitude modulator Study of
frequency modulator Frequency detector Resonance amplifier of high frequency
Quantization of signals and their synthesis on discrete samples Frequency conversion
Modules / Components:
Single-phase Power Supply ; Power Supply Unit ; Generator Unit Based on Oscillator
Harmonic Oscillations with Wien Bridge Generator;Aperiodic Amplifier Unit ;Feedback
Amplifier Unit ;Resonance Amplifier Unit ;Linear Circuits Unit ;Nonlinear Circuits Unit
Signal Sampling and Reconstruction Unit ; Frequency Converters Unit ; Frequency
Detectors Unit ;Amplitude Modulator Unit;Frequency Modulator Unit
Two Multimeters Unit
R-L-C Gauge
Laboratory table
USB oscilloscope with Software
Notebook
Signal Generator
Accessories Kit
Basic Experiments Guide

Page 193
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
SMART GRIDS G A L S E N
No Name of Equipment Quantity
1 Smart Electric Distribution Grid 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
UMRES1-S-K Please Contact Us
Ordering Information
Basic Experiments:
Detecting active power losses in local power distribution grid composed by loop scheme
Evaluation of effect of difference in the voltages at the busbars of the power centers
on loss of active power in local electric distribution grid, composed by loop scheme, when it
operates in closed mode Evaluation of effect of rupture of local electric distribution grid,
composed by loop scheme, on loss of active power Finding point of normal (optimal)
rupture in local electric distribution grid, composed by loop scheme, according to the
criterion of minimum active power losses Operation of local electric distribution grid,
made by loop scheme, in the mode of automatic point selection of normal (optimal)
rupture according to the criterion of minimum active power losses
Modules / Components
Single-phase Power Supply
Electric Transmission Line Model
Single-phase Transformer
Transformer Substation and Load Model
Single-phase Network Parameters Meter
Laboratory Table with 3-Level Frame
Notebook
Uninterruptible Power Supply
Accessories Kit
Basic Experiments Guide
Software

Page 194
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
NEW PRODUCTS G A L S E N
No Name of Equipment Quantity
1 Electric safety in electric installations 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 300 EBEU3-S-R Please Contact Us
Electric supply:
- three-phase AC circuit with P I C T U R E
working neutral and protective leads
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 3910
- width 850
- height 1600
Weight, Kg 200

Page 195
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS 4.1. Protection operating at damage of appliance system insulation, class I.
5. Human being protection against electric shock in electric installations up to
1000 V with grounding system TN-C.
Electric installations in single-phase network
5.1. Protection operating at human body direct touch to parts under voltage.
5.2. Protection operating at damage of appliance system insulation, class I.
1. Effect of electric current on human being in electric installations up to 1000 V. 5.3. Protection operating at wrong connection of null working and protective
1.1. Determination of electric current through human body at direct touch to parts conductors.
under voltage. 5.4. Protection operating at loss of null protective conductor.
1.2. Determination of electric current through human body at indirect touch to parts 6. Human being protection against electric shock in electric installations up to
under voltage. 1000 V with grounding system TN-C-S.
1.3. Study of influence of contact surface size on human body electric resistance. 6.1. Protection operating at human body direct touch to parts under voltage.
1.4. Study of influence of applied voltage frequency on human body electric 6.2. Protection operating at damage of appliance system insulation, class I.
resistance. 6.3. Protection operating at wrong connection of null working and protective
2. Measures to protect human being against electric shock in electric installations conductors.
up to 1000 V. 7. Human being protection against electric shock in electric installations up to
2.1. Operation of protective neutral grounding. 1000 V with grounding system TT.
2.2. Protective effect of automatic power-off when overcurrent. 7.1. Protection operating at human body direct touch to parts under voltage.
2.3. Protective effect of appliance double insulation. 7.2. Protection operating at damage of appliance system insulation, class 01.
1.0. 2.4. Operation of protective switching device (RCCB). 8. Human being protection against electric shock in electric installations up to
2.5. Operation of protective grounding. 1000 V with grounding system TI.
2.6. Protective effect of repetitive grounding of protective neutral conductor. 8.1. Protection operating at human body direct touch to parts under voltage.
2.7. Protective effect of small voltage. 8.2. Protection operating at damage of appliance system insulation, class 0.
2.8. Protective effect of network electric dividing. 8.3. Protection operating at damage of appliance system insulation, class II.
2.9. Monitoring phase insulation in network with isolated neutral. 9. Human being protection against electric shock in electric installations up to
3. Human being protection against electric shock in electric installations up to 1000 1000 V with grounding system IT.
V with grounding system TN-C and appliance body grounded. 9.1. Confirmation of unnecessary use of protective switching device (RCCB).
3.1. Confirmation of unnecessary use of protective switching device (RCCB). 9.2. Monitoring electric network insulation.
3.2. Confirmation of protection absence during human body direct touch to parts under Electric installations in three-phase network
voltage.
3.3. Protection operating at damage of appliance system insulation, class I.
2. Study of factors influencing on electric safety.
4. Human being protection against electric shock in electric installations up to 1000
2.1. Influence of shoes resistance (4 types) and ground resistance (4 types) on
1. ment.
electric safety.
1.1. Influence of electric network neutral mode on protective grounding efficiency.
2.2. Influence of neutral mode on electric safety.
2.3. Influence of electric network parameters (insulation resistance and capacitive
Page 196
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
3.1.
3.2. Protection operating at loss of null protective conductor.
3.3. Protection operating at damage of appliance system insulation, class 0.

1.1. Influence of phase-to-ground fault resistance in electric network with isolated neutral on electric safety.
2. Study of phenomena at current runoff into the earth through protective grounding electrode.
2.1. Finding dependence of electric installation body potential from distance from grounding electrode (for three types of grounding and five soil types).
2.2. Finding dependence of contact voltage from distance to grounding electrode (for three types of grounding and five soil types).
2.3. Finding dependence of step voltage from distance to grounding electrode (for three types of grounding and five soil types).

4. V with grounding system TN-C and appliance body isolated of ground.


4.1. Protection operating at human body direct touch to parts under voltage. Modeling electric equipment protective neutral grounding.
2.4. Influence of electric network neutral mode on protective neutral grounding efficiency.
2.5. Influence of neutral conductor resistance on electric safety conditions.
2.6. Influence of protective neutral conductor repetitive grounding on electric safety cjnditions.
2.7. Influence of phase-to-ground fault resistance in electric network with isolated neutral on electric safety.
3. Monitoring isolation of electric network with isolated neutral.
3.1. Monitoring isolation by three voltmeter method.
3.2. Monitoring isolation with special appliance.
4. Measurement of grounding resistance by voltmeter ammeter method for 4 types of soil.
Modeling protective grounding / self grounding of electric equip

4.1. Influence of five soil types on electric safety conditions.


4.2. Iinfluence of three excavator types on electric safety.
4.3. Influence of electric network parameters (insulation resistance and capacitive conductivity) on electric safety conditions.
5. Study of protective switching device (RCCB) operation.
5.1. Operation of protective switching device (RCCB) in electric network with solidly grounded neutral.
5.2. Operation of protective switching device (RCCB) in electric network with isolated neutral.

Page 197
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs 28 Multimeters Module (3 Multimeters) 1
1 Three-phase Power Supply 1 29 Laboratory Table with 2-level Frame 1
2 Single-phase Power Supply 1 30 Laboratory Table with single section storage container and 2-level frame 1
3 Three phase Transformer 1 31 Laboratory Table with storage container and 2-level frame 1
4 Electric Circuit Segment Model 1 32 Accessories Kit 1
5 Electric Circuit Segment Model 1 33 Basic Experiments Guide 1
6 Human Body Model 1 34 Basic Experiments Guide 1
7 Human Body Model 1 35 Operation Manual 1
8 Model of ground fault 1 36 Operation Manual 1
9 Insulation Resistance Model 1 37 Didactic Materials 1
10 Grounding Measurement Model 1
11 Grounding Control Model 1
12 Residual Current Device 1
13 Residual Current Device 1
14 Model of Grounding with Semispherical Electrode 1
15 Model of grounding with vertical tubular electrode 1
16 Model of Grounding with Long Tubular Electrode on Surface 1
17 Model of Protective Grounding / Self-grounding 1
18 Neutral Grounding Model 1
19 Linear Choke Model 1
20 Human Body Resistance Test Device 1
21 Automatic Single-pole Breaker 1
22 Electric Supply Grid Model 1
23 Model of electro receiver with working insulation 1
24 Model of electro receiver with double insulation 1
25 Step-down Transformer 1
26 Grounding Model 2
27 Isolation Transformer 1

Page 198
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
2 Model of electric system with asynchronized synchronous 1 Set Unit Prices Total Prices
generator Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 1000 EE1M-ASG-S-K Please Contact Us
Electric supply:
-three-phase AC circuit with P I C T U R E
working neutral and protective leads
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 3x910
- width 850
- height 1900
Weight, Kg 300

BASIC EXPERIMENTS

Electric power stations and substations

Main equipment of electric power stations and substations.

a. Synchronous generators.
i. Hand / automatic control of switching synchronous generator on parallel
operation by coarse synchronization.
ii. Hand / automatic control of switching synchronous generator on parallel
operation by ideal synchronization.
iii. Hand / automated control of synchronous generator mode operating in
parallel with infinite bus.

Page 199
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
iv. parallel with infinite bus. Hand / automatic control of synchronous Transients in electric power systems
generator mode operating in 1.1. Electromagnetic transients.
v. Hand control of synchronous generator autonomous mode. 1.2. Idly transformer switching-in to main transient.
vi. Synchronous generator field killing. 1.3. Symmetrical fault transient in grid with supply from practically infinite bus.
b. Power transformers. . 1.4. Symmetrical fault transient in grid with supply from synchronous generator.
i. Modeling transformer steady state. 1.5. Asymmetrical fault transient in grid with supply from practically infinite bus.
c. Synchronous compensators. 1.6. Phase failure transient in grid with supply from practically infinite bus.
1.3.1. Synchronous compensator start-up and reactive power regulation. 1.7. Double phase-to-ground fault transient in grid with insulated neutral and supply
2. Auxiliary needs of electric power stations and substations. from practically infinite bus.
a. Direct-on-line / reactor start of induction motor. 1.8. Single phaseto-ground and phase failure transient in grid with grounded neutral
b. Self-running of induction motor. and supply from practically infinite bus.
2. Electromechanical transients.
Electric power systems and grid. 2.1. Transient in single-machine electric power system at switching-in synchronous
1. Steady states of electric grid elements. generator to grid.
1.1. Modeling steady state of three-phase transformer. 2.2. Synchronous generator power angle characteristics.
1.2. Modeling steady state of three-phase transmission line. 2.3. Loss of stability during slow generator loading.
2. Steady states of electric grid. 2.4. Transient in single-machine electric power system at short-circuit in transmission
2.1. Modeling steady state of an electric grid phase with single supply. line.
2.2. Modeling steady state of an electric grid phase with duplicate supply. 2.5. Transient in single-machine electric power system at generator field loss.
2.3. Modeling steady state of three-phase electric grid with single supply. 2.6. Critical fault clearance time in single-machine electric power system.
3. Steady states of electric power system. 2.7. Transient in single-machine electric power system at pulling generator in
3.1. Consumed active/reactive power effect on electric power system synchronism without field loss.
mode. 2.8. Transient in single-machine electric power system at pulling generator in
3.2. Generated active/reactive power effect on electric power system synchronism with temporary field loss.
mode.
4. Voltage regulation in grid. Relay protection and automation of electric power systems
4.1. Counter voltage regulation. 1. Relay protection of electric power systems.
4.2. Voltage regulation by shunt reactive power compensation using 1.1. Schemes of measuring transformers connection.
capacitor package. 1.1.1. Schemes of current transformers connection.
4.3. Voltage regulation by series reactive power compensation using 1.1.2. Schemes of voltage transformers connection.
capacitor package.

Page 200
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
2.3. Protection of transmission lines. 1.1.3. Automatic switching-in synchronous generator in
2.3.1. Overcurrent protection / cutoff of two transmission lines with single supply. parallel by ideal synchronization.
2.3.2. Directional current protection of transmission lines in ring grid. 1.2. Frequency and active power automatic control.
2.3.3. Ground fault protection of grid with big ground fault current. 1.2.1. Autonomous electric power system frequency automatic
2.3.4. Nonselective alarm of ground fault in grid with small ground fault current. regulation.
2.3.5. Longitudinal differential protection of transmission line. 1.2.2. Active power automatic control of synchronous
2.3.6. Transverse differential protection of parallel transmission lines. generator working in parallel to infinite bus.
2.3.7. Distance protection of transmission lines in grid with duplicate supply. 1.3. Voltage and reactive power automatic control.
2.4. Busbar protection. 1.3.1. Voltage automatic regulation by synchronous generator
2.4.1. Differential busbar protection. field changing.
2.4.2. Current busbar cutoff. 1.4. Automatic control of electric power system mode.
2.4.3. Distance busbar protection. 1.4.1. Automatic control of autonomous single-machine
2.5. Power transformer protection. electric power system mode.
2.5.1. Differential transformer protection. 1.4.2. Automatic control of mode of single-machine electric
2.5.2. Overcurrent transformer protection. power system operating in parallel to infinite bus.
2.5.3. Negative phase-sequence transformer protection. 2. Emergency automation of electric power systems.
2.5.4. Zero-sequence current transformer protection. 2.1. Automation of fault clearing, reclosing and back-up.
2.6. Relay protection and breakers back-up. 2.1.1. Automatic fault clearing on transmission line with single
2.6.1. Circuit-breaker failure protection. supply.
2.6.2. Synchronous generator protection. 2.1.2. Automatic reclosing transmission line with single
2.6.3. Differential generator protection. supply.
1.5.4.Overcurrent and overload generator protection. 2.1.3. Automatic reclosing transmission line with duplicate
2.7. Generator-transformer unit protection. supply.
2.7.1. Differential generator-transformer unit protection. 2.1.4. Automatic switching-in step-down substation section
2.8. Induction motor protection. switch.
2.8.1. Overcurrent induction motor protection. 2.2. Automatic stability control.
2.8.2. Differential induction motor protection. 2.2.1. Automatic control of dynamic stability by synchronous
2.8.3. Low-voltage induction motor protection. generator field forcing..
3. Automation of electric power systems normal modes. 2.2.2. Automatic control of dynamic stability by quick short-
3.1. Automatic switching-in synchronous generator in parallel. time synchronous generator prime mover power
3.1.1. Automatic switching-in synchronous generator in parallel by coarse reduction.
synchronization.

Page 201
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
3.1.2. Automatic asynchronous Name Pcs
3.1.3. 1 Electromechanical unit with flywheel (induction motor, AC machine, and 1
3.1.4. Automatic control of dynamic stability by synchronous angular displacement transducer)
generator electric braking. mode prevention.
2 Three-phase power supply 1
3.1.5. Automatic prevention of asynchronous mode caused by
transmission line overload. 3 Synchronous machine exciter 2
3.1.6. Automatic prevention of asynchronous mode caused by 4 Single-phase power supply 1
synchronous generator field loss. 5 Turbine model power supply 1
3.2. Automatic prevention of unacceptable changes of regime 6 Three-pole breaker 6
parameters. 7 Terminal 1
3.2.1. Automatic voltage drop limitation by series capacitive
8 Active load 1
compensation of transmission line.
3.2.2. Automatic voltage rise limitation by shunt reactor at 9 Model of transmission line 2
transmission line end. 10 Line reactor 1
11 Series capacitive compensating device 1
3.3. Steady states of asynchronized synchronous generator in electric 12 Capacitive load 1
power system 13 Module of synchronizing 1
3.3.1. Idling characteristics of asynchronized synchronous generator. 14 Inductive load 1
. 15 Connector 1
3.3.2. Switching-in asynchronized synchronous generator on parallel
16 Module of digital signals input/output 1
operation by ideal synchronization.
3.3.3. Regulating characteristics of asynchronized synchronous 17 Module of diodes 1
generator at parallel operation. 18 Three-phase transformer group 2
19 Three-phase transformer group 1
20 Power meter commutater 2
21 Module of varistors 1
22 Module of current-and-voltage transformers 2
23 Module of current-and-voltage sensors 1
24 Voltage-and-frequency meter 1
34 Accessories Kit 1
35 Basic Experiments Guide Relay protection of electric power systems 1

Page 202
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
36 Synchronous machine torque angle meter 1
37 Speed indicator 1
38 Power meter 1
28 Module of 3 multimeters 1
39 Multifunctional electrical measuring instrument 2
40 Laboratory table with 2-section storage container and 3-level frame 1
34 Storage rack for functional modules 1
42 Laboratory table with storage container for wires and 3-level frame 1
43 Laboratory table with computer rack and pullout keyboard shelf and 3-level frame 1
44 Basic Experiments Guide Automation of electric power systems 1
45 Basic Experiments Guide Electric power systems 1
46 Basic Experiments Guide Transients in electric power systems 1
47 Basic Experiments Guide Steady states of asynchronized synchronous generator in electric power 1
system
48 Basic Experiments Guide Electric power stations and substations 1
49 Operation manual 1
50 Didactic materials and Software CD 1
51 Personal computer 1

Page 203
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
3 Electric power engineering - Long-distance extra-high voltage 1 Set Unit Prices Total Prices
transmission Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 500 EE1M-DEP-S-R Please Contact Us
Electric supply:
- three-phase AC circuit with P I C T U R E
working neutral and protective leads
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 2910
- width 850
- height 1600
Weight, Kg 200
Module / Component Pcs
1 Three-phase Power Supply 1
2 Infinite Power Busbars 2
3 Single-phase Power Supply 1
4 Three-pole Breaker 1
5 Active Load 1
6 Transmission Line Model 4
7 Line Reactor 2
8 Series Capacitive Compensating Device 1
9 Induct ve Load 1
10 Power Meter Commutator 3
11 Shunt Reactor 2

Page 204
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
12 Single-phase Network Parameters Meter 2
13 Laboratory Table with 2-level Frame 1
14 Laboratory Table with 2-section Storage Container and 2-level Frame 1
15 Accessories Kit 1
16 Basic Experiments Guide 1
17 Operation Manual 1
18 Didactic Materials CD 1

BASIC EXPERIMENTS

1. Studying steady state of long-distance transmission line with a quarter wavelength / 4,


connecting electric system with load.
2. Studying steady state of long-distance transmission line with a half wavelength / 2,
connecting electric system with load.
3. Series inductive or shunt capacitive compensation of long-distance transmission line to
increase its length to a half wavelength / 2.
4. Series capacitive or shunt inductive compensation of long-distance transmission line to
decrease its length.
5. Studying steady state of long-distance transmission line with a quarter wavelength / 4,
connecting powerful electric systems.
6. Studying steady state of long-distance transmission line with a half wavelength / 2,
connecting powerful electric systems.

Page 205
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
4 Electric power engineering - Electric measurements in electric 1 Set Unit Prices Total Prices
power stations & substations Type / Model ( Rupiah ) ( Rupiah )
EE1M-EIESP-S-R Please Contact Us
Ordering Information
Power consumption, VA 300
Electric supply:
- three-phase AC circuit with
working neutral and protective leads
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1900
Weight, Kg 130

BASIC EXPERIMENTS

Measuring AC current by shield pointer ammeter with its direct connection and
connection through measuring current transformer.
a. Measuring AC voltage by shield pointer voltmeter with its direct connection.
b. Measuring AC voltage by shield digit voltmeter with its connection through measuring
voltage transformer.
c. Measuring frequency of AC voltage by shield digit frequency indicator with its direct
connection and connection through measuring voltage transformer.
d. Measuring active power in three-phase three-wire electric network by pointer shield

Page 206
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
e. wattmeter when connected via two current and two voltage measuring transformers. Module / Component Pcs
f. Measuring power factor in three-phase three-wire electric network by shield pointer meter 1 Three-phase Power Supply 1
when connected via two current and two voltage measuring transformers. 2 Single-phase Power Supply 1
g. Measuring voltages, currents, power, frequency and power factor in three-phase four-
3 Active Load 1
wire electric network by shield pointer multifunctional electric measuring device with its
direct connection. 4 Inductive Load 1
h. Measuring active and reactive power in three-phase AC circuit by electronic counter 5 Current Transformer 3
when connected through measuring current and voltage transformers. 6 Voltage Transformer 3
7 Power Factor Meter 1
8 Frequency Meter 1
9 Voltmeter 1
10 Voltmeter 1
11 Ammeter 1
12 Three-phase Wattmeter 1
13 Module of Three-phase Single-rate Meter of Active and Reactive Energy 1
for the Network 100/3 V
14 Multifunctional Electric Measurement Device 1
15 Laboratory Table with 2-section Storage Container and 3-level Frame 1
16 Accessories Kit 1
17 Basic Experiments Guide 1
18 Operation Manual 1
19 Didactic Materials CD 1

Page 207
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
5 Electric power engineering Electric power stations & 1 Set Unit Prices Total Prices
substations Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 1000 EE1M-ESP-S-K Please Contact Us
Electric supply:
- three-phase AC circuit with P I C T U R E
working neutral and protective leads
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 3910
- width 850
- height 1900
Weight, Kg 300

Page 208
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS

1. Basic equipment of electric power stations and substations.


a. Synchronous generators.
i. Manual / Automatic switching-in synchronous generator for parallel operation by means of self-synchronization.
ii. Manual / Automatic switching-in synchronous generator for parallel operation by means of precise synchronization.
iii. Manual / Automatic control of synchronous generator mode when operating in parallel to infinite bar system.
iv. Manual control of mode of autonomously operating synchronous generator.
v. Quenching synchronous generator field.
b. Power transformers.
i. Modeling transformer steady state.
c. Synchronous compensators.
1.3.1. Start of synchronous compensator and regulation of reactive power.
2. Auxiliaries of electric power stations and substations.
a. Direct-on-line / Reactor start of induction motor.
b. Autostart of induction motor.
3. Short-circuits in electric installations.
a. Short-circuit current.
i. Registration and display of current curve of three-phase short circuit in electric network powered from infinite buses.
ii. Registration and display of current curve of three-phase short circuit in electric network powered from synchronous generator.
b. Determining ratio of short-circuit currents of different faults in the same point in the network, powered from infinite buses.
c. Short-circuit current limitation.
i. Limiting short-circuit current by changing output distribution scheme of power station.
ii. Limiting short-circuit current by network splitting.
iii. Limiting short-circuit current by network sectionalization.
iv. Limiting short-circuit current by means of line reactor.
v. Limiting short-circuit current by using transformer with low-voltage winding splitted.
vi. Limiting ground short-circuit current in network with effective neutral grounding by removing transformer neutral grounding.
vii. Limiting ground short-circuit current in network with effective neutral grounding by including reactor into transformer neutral.

4. Neutral modes in electric installations.


a. Modeling neutral modes in electric installation by changing transformer neutral reactor reactance; finding dependences of sustained single-phase fault current, unfaulty phase and
neutral voltages from reactor reactance.

Page 209
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
a. Modeling neutral modes in electric installation by changing transformer neutral resistance; finding dependences of sustained single-phase fault current, unfaulty phase
and neutral voltages from the resistance.
b. Defining influence of removing transformer neutral on mode of effective neutral grounding in electric installation.
c. Finding dependences of sustained single-phase fault current, phases voltages from fault resistance in mode of electric installation isolated neutral.
d. Finding dependences of phase voltages, grounding transformer neutral voltage and sustained single-phase fault current from fault resistance in mode of electric installation
compensated neutral.
e. Finding dependences of phase voltages, grounding transformer neutral voltage and sustained single-phase fault current from fault resistance in network with resistive
neutral grounding.
5. Ground arrangements of electric installations.
a. Finding dependence of electric installation base potential from distance to ground (for 5 soil types).
b. Finding dependence of contact voltage from distance to ground (for 5 soil types).
c. Finding dependence of step voltage from distance to ground (for 5 soil types).
1 Electromechanical unit with flywheel (induction motor, AC machine 1
102.1, and angular displacement transducer)
Module / Component Pcs 2 Three-phase Power Supply 1
17 Digital Signals I/O Module 1 3 Synchronous Machine Exciter 1
18 Three-phase Transformer Group 1 4 Single-phase Power Supply 1
19 Three-phase Transformer Group 1 5 Turbine Model Power Supply 1
20 Varistors Module 1 6 Three-pole Breaker 3
21 Three-phase two-winding transformer with split low voltage winding 1 7 Terminal 1
22 Current-and-voltage Transformers Module 1 8 Active Load 1
23 Current-and-voltage Sensors Module 1 9 Model of ground fault 1
24 Voltage-and-frequency Meter 1 10 Transmission Line Model 2
25 Synchronous Machine Torque Angle Meter 1 11 Line Reactor 1
26 Speed Indicator 1 12 Synchronization Module 1
27 Power Meter 1 13 Rheostat 1
28 Multimeters Module (3 Multimeters) 1 14 Inductive Load 1
29 Laboratory Table with 2-section Storage Container and 3-level Frame 1 15 Model of grounding with vertical tubular electrode 1
16 Connector 1

Page 210
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
30 Laboratory Table with Wires Storage Container and 3-level Frame 1
31 Laboratory Table with Computer Rack and 3-level Frame 1
32 Accessories Kit 1
33 Basic Experiments Guide 1
34 Basic Experiments Guide 1
35 Operation Manual 1
36 Software CD 1
37 Personal Computer 1

Page 211
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
6 Model of 1-machine electric system with DC link 1 Set Unit Prices Total Prices
Power consumption, VA 500 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
-three-phase AC circuit with EE1M-LVPT-S-K Please Contact Us
working neutral and protective leads P I C T U R E
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 3x910
- width 850
- height 1900
Weight, Kg 500

Electric power stations & substations

3. Basic equipment of electric power stations and substations.


a. Synchronous generators.
i. Manual / Automatic switching-in synchronous generator for parallel
operation by means of self-synchronization.
ii. Manual / Automated switching-in synchronous generator for parallel
operation by means of precise synchronization.
iii. Manual / Automatic switching-in synchronous generator for parallel
operation by means of precise synchronization.
iv. Manual / Automatic control of synchronous generator mode when operating
in parallel to infinite bar system.
v. Manual control of mode of autonomously operating synchronous generator.
b. Quenching synchronous generator field.
c. Synchronous compensators.

Page 212
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.3.1. Start of synchronous compensator and regulation of reactive power. 4.2. Viewing and registering measured quality parameters of electrical energy
4. Auxiliaries of electric power stations and substations. using personal computer.
a. Direct-on-line / Reactor starting of induction motor. Transients in electric power systems
b. Self-starting of induction motor.
5. Electromagnetic transients.
Electric power systems and grid 5.1. No-load transformer turn-on transient.
2. Steady states of electric grid elements.. 5.2. Symmetrical short-circuit transient in electric network supplied from
4.4. Modeling steady state of three-phase transformer. infinite bus.
4.5. Modeling steady state of three-phase transmission line. 5.3. Symmetrical short-circuit transient in electric network supplied from
5. Steady states of electric grid. synchronous generator.
5.1. Modeling steady state of an electric grid phase with single supply. 5.4. Asymmetrical short-circuit transient in electric network supplied from
5.2. Modeling steady state of an electric grid phase with duplicate supply. infinite bus.
5.3. Modeling steady state of three-phase electric grid with single supply. 5.5. Loss of single phase transient in electric network supplied from infinite
6. Steady states of electric power system. bus.
6.1. Consumed active/reactive power effect on electric power system mode. 5.6. Line-to-line-to-ground short-circuit transient in electric network with
6.2. Generated active/reactive power effect on electric power system mode. isolated neutral supplied from infinite bus.
7. Voltage regulation in grid. 5.7. Single phase short-circuit and loss of single phase transient in electric
7.1. Counter voltage regulation. network with grounded neutral supplied from infinite bus.
7.2. Voltage regulation by shunt reactive power compensation using capacitor 6. Electromechanical transients.
package. 6.1. Synchronous generator turn-on to electric network transient in single-
7.3. Voltage regulation by series reactive power compensation using capacitor machine electric power system.
package. 6.2. Finding synchronous generator power angle characteristics.
Electric power supply 6.3. Generator stability loss during its slow loading.
3. Electroreceiver modes. 6.4. Transmission line short-circuit transient in single-machine electric power
3.1. Static power - voltage characteristic of resistive load. system.
3.2. Static power - voltage characteristic of inductive load (reactor). 6.5. Generator field loss transient in single-machine electric power system.
3.3. Static power - voltage characteristic of capacitor bank. 6.6. Short-circuit clearing time limit in single-machine electric power system..
3.4. Static power - voltage characteristic of lighting load. 6.7. Synchronous generator resynchronizing transient without field loss in
3.5. Static power - voltage characteristic of rectifier load. single-machine electric power system.
3.6. Static power - voltage characteristic of induction load. 6.8. Synchronous generator resynchronizing transient with temporary field
4. Quality control of electrical energy in power supply systems. loss in single-machine electric power system..
4.1. Measuring parameters of electric energy quality.

Page 213
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Relay protection & Automation of electric power systems 1.1.1. Induction motor overcurrent protection. Differential induction
4. Relay protection of electric power systems. motor protection..
4.1. Circuits of measuring transformer. 1.1.2. Induction motor undervoltage protection..
4.1.1. Current transformer. 2. Automation of normal modes of electric power systems.
4.1.2. Voltage transformer. 2.1. Automatic switching-in synchronous generator for parallel
4.2. Transmission lines protection. operation.
4.2.1. Transmission line overcurrent protection /Cutoff of two transmission 2.1.1. Automatic switching-in synchronous generator for parallel
lines with single supply. operation by means of self-synchronization.
4.2.2. Current directional protection of transmission lines in the ring. 2.1.2. Automatic switching-in synchronous generator for parallel
4.2.3. Protection against ground faults in network with large ground short- operation by means of precise synchronization.
circuit current . 2.2. Automatic regulation of frequency and active power..
4.2.4. Nonselective signaling against ground faults in network with small 2.2.1. Automatic regulation of autonomous generator frequency.
ground short-circuit current . 2.2.2. Automatic regulation of active power of generator operating in
4.2.5. Longitudinal differential protection of transmission lines. parallel to infinite bus.
4.2.6. Transverse differential protection of parallel transmission lines. 2.3. Automatic regulation of voltage and reactive power.
4.2.7. Distance protection of transmission lines with double supply. 2.3.1. Automatic regulation of voltage by changing synchronous
4.3. Busbar protection. generator excitation.
4.3.1. Differential busbar protection. 2.4. Automatic control of electrical system mode.
4.3.2. Busbar cutoff. 2.4.1. Automatic control of autonomous single-machine electric power
4.4. Transformer protection. system mode.
4.4.1. Differential transformer protection. 2.4.2. Automatic control of mode of single-machine electric power
4.4.2. Transformer overcurrent protection. system operating in parallel to infinite bus.
4.4.3. Transformer reverse-sequence current protection. 3. Emergency automation of electric power systems.
4.4.4. Transformer zero-sequence current protection.. 3.1. Automation of fault clearance, reclosing and back-up switching-in.
4.5. Relay protection and circuit breaker back-up. 3.1.1. Automatic clearance of short-circuit on transmission line with
4.5.1. Circuit breaker failure protection. single supply.
4.6. Synchronous generator protection. 3.1.2. Automatic reclosing of transmission line with single supply.
4.6.1. Differential generator protection. 3.1.3. Automatic reclosing of transmission line with double supply.
4.6.2. Generator protection against overcurrent and overload. 3.1.4. Automatic back-up witching-in section switch of step-down
4.7. Generator transformer unit protection. substation.
4.7.1. Differential generator transformer unit protection. 3.2. Automatic prevention of instability.
4.8. Induction motor protection. 3.2.1. Automatic prevention of dynamic stability violation by
synchronous generator field forcing.

Page 214
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
4.8.1.Automatic limitation of voltage drop by switching-in longitudinal 3. Operation of three-phase double-bridge converter in rectifier mode.
capacitive compensation of power line. 3.1. External characteristic of three-phase double-bridge converter in rectifier mode
4.8.2. Automatic limitation of voltage rise by switching-in shunt reactor (active-inductive load).
at the end of power line. 3.2. Parameters of valves operation in three-phase double-bridge converter in
4.8.3. Automatic prevention of dynamic stability violation by quick rectifier mode (active-inductive load).
short-term decrease of synchronous generator primary motor 3.3. Harmonic components of rectified voltage and input current of three-phase
power. double-bridge converter operation in rectifier mode (active-inductive load).
4.8.4. Automatic prevention of dynamic stability violation by electric 3.4. Operation of three-phase double-bridge converter in inverter mode.
braking of synchronous generator. 3.5. Input characteristic of three-phase double-bridge converter in inverter mode.
4.9. Automatic termination of asynchronous mode. 3.6. Parameters of valves operation in three-phase double-bridge converter in
4.9.1. Automatic terminating asynchronous mode, caused by power inverter mode.
line overloading. 3.7. Parameters of three-phase double-bridge converter operation in inverter
4.9.2. Automatic terminating asynchronous mode, caused by mode..
synchronous generator field loss. 3.8. Operation of transmission line and DC link.
4.10.Automatic prevention of unacceptable changes of mode 3.9. Regulation of DC transmission line operation mode. .
parameters. Regulation of DC link connecting autonomous electric power systems.
Transmission line and DC link

1. Operation of three-phase single-bridge converter in rectifier mode.


1.1. External characteristic of three-phase single-bridge converter in rectifier
mode (active-inductive load).
1.2. Parameters of valves operation in three-phase single-bridge converter in
rectifier mode (active-inductive load).
1.3. Parameters of three-phase single-bridge converter operation in rectifier
mode (active-inductive load).
1.4. Harmonic components of rectified voltage and input current of three-phase
single-bridge converter operation in rectifier mode (active-inductive load).
2. Operation of three-phase single-bridge converter in inverter mode.
2.1. Input characteristic of three-phase single-bridge converter in inverter mode..
2.2. Parameters of valves operation in three-phase single-bridge converter in
inverter mode.
2.3. Parameters of three-phase single-bridge converter operation in inverter
mode.

Page 215
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Name Pcs 24 Smoothing reactor 1
1 Electromechanical unit with flywheel (induction motor, AC machine, and 1 25 Module of chokes 2
angular displacement transducer) 26 Three-phase transformer group 2
2 Three-phase power supply 1 27 Three-phase transformer group 1
3 Thyrister converter/regulator 1 28 Power meter commutater 2
4 Thyrister converter/regulator 1 29 Module of varistors 1
5 Synchronous machine exciter 1 30 Module of current-and-voltage transformers 2
6 Single-phase power supply 1 31 Module of current-and-voltage sensors 1
7 Turbine model power supply 1 32 Voltage-and-frequency meter 1
8 Three-pole breaker 6 33 Synchronous machine torque angle meter 1
9 Terminal 1 34 Speed indicator 1
10 Active load 1 35 Power meter 1
11 Model of transmission line 2 36 Module of 3 multimeters 1
12 Line reactor 2 37 Multifunctional electrical measuring instrument 2
13 Series capacitive compensating device 1 38 Laboratory table with 2-section storage container and 3-level frame 1
14 Capacitive load 1 39 Storage rack for functional modules 1
15 Adjustable autotransformer 1 40 Laboratory table with storage container for wires and 3-level frame 1
16 Module of synchronizing 1 41 Laboratory table with computer rack and pullout keyboard shelf and 1
17 Rectifier 1 3-level frame
18 Rheostat 1 42 Accessories Kit 1
19 Inductive load 1 43 Basic Experiments Guide Relay protection of electric power systems 1
20 Connector 1 44 Basic Experiments Guide Automation of electric power systems 1
21 Module of digital signals input/output 1 45 Basic Experiments Guide Electric power systems 1
22 Module of diodes 1 46 Basic Experiments Guide Transients in electric power systems 1
23 Converter transformer 2 47 Basic Experiments Guide Electric transmission line and DC link 1
48 Basic Experiments Guide Electric power stations and substations 1
49 Operation manual 1

Page 216
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
7 Electric power engineering - Relay protection & automation of 1 Set Unit Prices Total Prices
electric power systems Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 500 EE1M-RZAES-S-K Please Contact Us
Electric supply:
- three-phase AC circuit with P I C T U R E
working neutral and protective leads
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 2910
- width 850
- height 1600
Weight, Kg 150

BASIC EXPERIMENTS
1. Relay protection of electric power systems.
1.1. Circuits of measuring transformer.
1.1.1. Current transformer.
1.1.2. Voltage transformer.
1.2. Transmission lines protection.
1.2.1. Transmission line overcurrent protection /Cutoff of two transmission
lines with single supply.
1.2.2. Current directional protection of transmission lines in the
ring.
.
1.2.3. Protection against ground faults in network with large ground short-

Page 217
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.5.1. circuit current . 1.3.supply.
1.5.2. Nonselective signaling against ground faults in network with small
ground short-circuit current . 1.4.Automatic backup switching-in section switch at
1.5.3. Longitudinal differential protection of transmission step-down substation.
lines. 1.5.Automatic limitation of voltage drop by switching-in
1.5.4. Transverse differential protection of parallel longitudinal capacitive compensation of transmission
transmission lines. line.
1.5.5. Distance protection of transmission lines with double Automatic limitation of voltage rise by switching-in shunt
supply.
1.6.Busbar protection.
1.6.1. Differential busbar protection.
1.6.2. Busbar cutoff.
1.7.Transformer protection.
1.7.1. Differential transformer protection.
1.7.2. Transformer overcurrent protection.
1.7.3. Transformer reverse-sequence current protection.
1.7.4. Transformer zero-sequence current protection..
1.8.Relay protection and circuit breaker back-up.
1.8.1. Circuit breaker failure protection.
2. Automation of electric power systems.
2.1.Automatic fault clearance procedure in transmission line
with single supply.
2.2.Automatic reclosure of transmission line with single supply.
2.3.Automatic reclosure of transmission line with double
2.4.reactor on transmission line end.

Page 218
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs
1 Three-phase Power Supply 1
2 Single-phase Power Supply 1
3 Three-pole Breaker 6
4 Terminal 1
5 Active Load 1
6 Transmission Line Model 2
7 Line Reactor 1
8 Series Capacitive Compensating Device 1
9 Capacitive Load 1
10 Inductive Load 1
11 Connector 1
12 Digital Signals I/O Module 1
13 Three-phase Transformer Group 2
14 Current-and-voltage Transformers Module 2
15 Laboratory Table with 2-section Storage Container and 2-level Frame 1
16 Laboratory Table with Computer Rack and 2-level Frame 1
17 Accessories Kit 1
18 Basic Experiments Guide 1
19 Basic Experiments Guide 1
20 Operation Manual 1
21 Software and Didactic CD 1
22 Personal Computer 1

Page 219
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
8 Electric power engineering - Model of single-machine electric 1 Set Unit Prices Total Prices
power system Type / Model ( Rupiah ) ( Rupiah )
EE2M-B-S-K Please Contact Us
Power consumption, VA 1000 P I C T U R E
Electric supply:
- three-phase AC circuit with
working neutral and protective leads
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 3910
- width 850
- height 1900
Weight, Kg 300
BASIC EXPERIMENTS

Electric power stations & substations


1. Basic equipment of electric power stations and substations.
a. Synchronous generators.
i. Manual / Automatic switching-in synchronous generator for parallel
operation by means of self-synchronization.
ii. Manual / Automated switching-in synchronous generator for parallel
operation by means of precise synchronization.
iii. Manual / Automatic switching-in synchronous generator for parallel
operation by means of precise synchronization.

iv. Manual / Automatic control of synchronous generator mode when


operating in parallel to infinite bar system.

Page 220
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
v. Manual control of mode of autonomously operating synchronous Transients in electric power systems
generator.
vi. Quenching synchronous generator field. 1. Electromagnetic transients.
b. Power transformers. 1.1. No-load transformer turn-on transient.
i. Modeling transformer steady state. 1.2. Symmetrical short-circuit transient in electric network supplied from infinite bus.
c. Synchronous compensators. 1.3. Symmetrical short-circuit transient in electric network supplied from
1.3.1. Start of synchronous compensator and regulation of reactive power. synchronous generator.
2. Auxiliaries of electric power stations and substations. 1.4. Asymmetrical short-circuit transient in electric network supplied from infinite
a. Direct-on-line / Reactor starting of induction motor. bus.
b. Self-starting of induction motor. 1.5. Loss of single phase transient in electric network supplied from infinite bus.
Electric power systems and grid 1.6. Line-to-line-to-ground short-circuit transient in electric network with isolated
neutral supplied from infinite bus.
1. Steady states of electric grid elements.. 1.7. Single phase short-circuit and loss of single phase transient in electric network
1.1. Modeling steady state of three-phase transformer. with grounded neutral supplied from infinite bus.
1.2. Modeling steady state of three-phase transmission line. 2. Electromechanical transients.
2. Steady states of electric grid. 2.1. Synchronous generator turn-on to electric network transient in single-machine
2.1. Modeling steady state of an electric grid phase with single supply. electric power system.
2.2. Modeling steady state of an electric grid phase with duplicate supply. 2.2. Finding synchronous generator power angle characteristics.
2.3. Modeling steady state of three-phase electric grid with single supply. 2.3. Generator stability loss during its slow loading.
3. Steady states of electric power system. 2.4. Transmission line short-circuit transient in single-machine electric power
3.1. Consumed active/reactive power effect on electric power system mode. system.
3.2. Generated active/reactive power effect on electric power system mode. 2.5. Generator field loss transient in single-machine electric power system.
4. Voltage regulation in grid. 2.6. Short-circuit clearing time limit in single-machine electric power system..
4.1. Counter voltage regulation. 2.7. Synchronous generator resynchronizing transient without field loss in single-
4.2. Voltage regulation by shunt reactive power compensation using capacitor machine electric power system.
package. 2.8. Synchronous generator resynchronizing transient with temporary field loss in
Voltage regulation by series reactive power compensation using capacitor package. single-machine electric power system.
1.2. Transmission lines protection. Relay protection & Automation of electric power systems
1.2.1. Transmission line overcurrent protection /Cutoff of two
transmission lines with single supply. 1. Relay protection of electric power systems.
1.1. Circuits of measuring transformer.
1.1.1. Current transformer.
1.1.2. Voltage transformer.

Page 221
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.2.2. Current directional protection of transmission lines in the ring. 2.2.1. Automatic regulation of autonomous generator frequency.
1.2.3. Protection against ground faults in network with large ground short-circuit 2.2.2. Automatic regulation of active power of generator
current . operating in parallel to infinite bus.
1.2.4. Nonselective signaling against ground faults in network with small ground 2.3. Automatic regulation of voltage and reactive power.
short-circuit current . 2.3.1. Automatic regulation of voltage by changing synchronous
1.2.5. Longitudinal differential protection of transmission lines. generator excitation.
1.2.6. Transverse differential protection of parallel transmission lines. 2.4. Automatic control of electrical system mode.
1.2.7. Distance protection of transmission lines with double supply. 2.4.1. Automatic control of autonomous single-machine electric
1.3. Busbar protection. power system mode.
1.3.1. Differential busbar protection. 2.4.2. Automatic control of mode of single-machine electric
1.3.2. Busbar cutoff. power system operating in parallel to infinite bus.
1.4. Transformer protection. 2.4.3. Current directional protection of transmission lines in the
1.4.1. Differential transformer protection. ring.
1.4.2. Transformer overcurrent protection. 2.4.4. Protection against ground faults in network with large
1.4.3. Transformer reverse-sequence current protection. ground short-circuit current .
1.4.4. Transformer zero-sequence current protection.. 2.4.5. Nonselective signaling against ground faults in network
1.5. Relay protection and circuit breaker back-up. with small ground short-circuit current .
1.5.1. Circuit breaker failure protection. 2.4.6. Longitudinal differential protection of transmission lines.
1.6. Synchronous generator protection. 2.4.7. Transverse differential protection of parallel transmission
1.6.1. Differential generator protection. lines.
1.6.2. Generator protection against overcurrent and overload. 2.4.8. Distance protection of transmission lines with double
1.7. Generator transformer unit protection. supply.
1.7.1. Differential generator transformer unit protection. 2.5. Busbar protection.
1.8. Induction motor protection. 2.5.1. Differential busbar protection.
1.8.1. Induction motor overcurrent protection. 2.5.2. Busbar cutoff.
1.8.2. Differential induction motor protection.. 2.6. Transformer protection.
1.8.3. Induction motor undervoltage protection.. 2.6.1. Differential transformer protection.
2. Automation of normal modes of electric power systems. 2.6.2. Transformer overcurrent protection.
2.1. Automatic switching-in synchronous generator for parallel operation. 2.6.3. Transformer reverse-sequence current protection.
2.1.1. Automatic switching-in synchronous generator for parallel operation by 2.6.4. Transformer zero-sequence current protection..
means of self-synchronization. 2.7. Relay protection and circuit breaker back-up.
2.1.2. Automatic switching-in synchronous generator for parallel operation by 2.7.1. Circuit breaker failure protection.
means of precise synchronization. 2.8. Synchronous generator protection.
2.2. Automatic regulation of frequency and active power.. 2.8.1. Differential generator protection.
2.8.2. Generator protection against overcurrent and overload.

Page 222
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs 27 Power Meter 1
1 Electromechanical unit with flywheel (induction motor 101.1, AC machine 1 28 Multimeters Module (3 Multimeters) 1
102.1, and angular displacement transducer) 29 Multifunctional Electric Measurement Device 2
2 Three-phase Power Supply 1 30 Laboratory Table with 2-section Storage Container and 3-level Frame 1
3 DC Motor Power Supply 1 31 Storage Rack for Functional Modules 1
4 Synchronous Machine Exciter 1 32 Laboratory Table with Wires Storage Container and 3-level Frame 1
5 Single-phase Power Supply 1 33 Laboratory Table with Computer Rack and 3-level Frame 1
6 Three-pole Breaker 6 34 Accessories Kit 1
7 Terminal 1 35 Basic Experiments Guide 1
8 Active Load 1 36 Basic Experiments Guide 1
9 Transmission Line Model 2 37 Basic Experiments Guide 1
10 Line Reactor 1 38 Basic Experiments Guide 1
11 Series Capacitive Compensating Device 1 39 Basic Experiments Guide 1
12 Capacitive Load 1 40 Operation Manual 1
13 Synchronization Module 1 41 Didactic and Software CD 1
14 Inductive Load 1 42 Personal Computer 1
15 Connector 1
16 Digital Signals I/O Module 1
17 Diodes Module 1
18 Three-phase Transformer Group 2
19 Three-phase Transformer Group 1
20 Power Meter Commutator 2
21 Varistors Module 1
22 Current-and-voltage Transformers Module 2
23 Current-and-voltage Sensors Module 1
24 Voltage-and-frequency Meter 1
25 Synchronous Machine Torque Angle Meter 1
26 Speed Indicator 1

Page 223
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
9 Electric power engineering - Electric measurements in electric 1 Set Unit Prices Total Prices
power stations & substations Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 300 EE2M-EIESP-S-R Please Contact Us
Electric supply: P I C T U R E
- three-phase AC circuit with
working neutral and protective leads
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 2910
- width 850
- height 1600
Weight, Kg 150
BASIC EXPERIMENTS

1. Electric measurements.
a. Measuring AC current by shield pointer ammeter with its direct connection and
connection through measuring current transformer.
b. Measuring AC voltage by shield pointer voltmeter with its direct connection.
c. Measuring AC voltage by shield digit voltmeter with its connection through
measuring voltage transformer.

Page 224
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
d. Measuring frequency of AC voltage by shield digit frequency indicator with its direct Module / Component Pcs
connection and connection through measuring voltage transformer. 1 Three-phase Power Supply 1
e. Measuring active power in three-phase three-wire electric network by pointer shield 2 Single-phase Power Supply 1
wattmeter when connected via two current and two voltage measuring transformers.
3 Active Load 1
f. Measuring power factor in three-phase three-wire electric network by shield pointer
meter when connected via two current and two voltage measuring transformers. 4 Line Reactor 1
g. Measuring voltages, currents, power, frequency and power factor in three-phase 5 Adjustable Autotransformer 1
four-wire electric network by shield pointer multifunctional electric measuring device 6 Rheostat 1
with its direct connection. 7 Inductive Load 1
h. Measuring active and reactive power in three-phase AC circuit by electronic counter 8 Current Transformer 3
when connected through measuring current and voltage transformers. 9 Voltage Transformer 1
2. Measuring transformers.
10 Voltage Transformer 3
a. Determination of measuring current transformer error.
Determination of measuring voltage transformer error 11 Power Factor Meter 1
12 Frequency Meter 1
13 Multimeters Module (3 Multimeters) 1
14 Voltmeter 1
15 Voltmeter 1
16 Ammeter 1
17 Three-phase Wattmeter 1
18 Module of Three-phase Single-rate Meter of Active and Reactive 1
Energy for the Network 100/3 V
19 Multifunctional Electric Measurement Device 1
20 Laboratory Table with 2-level Frame 1
21 Laboratory Table with 2-section Storage Container and 2-level 1
Frame
22 Accessories Kit 1
23 Basic Experiments Guide 1
24 Operation Manual 1
25 Didactic Materials CD 1

Page 225
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
10 Electric power engineering - Electric power stations & 1 Set Unit Prices Total Prices
substations Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA 1000 EE2M-ESP-S-K Please Contact Us
Electric supply: P I C T U R E
- three-phase AC circuit with
working neutral and protective leads
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 3910
- width 850
- height 1900
Weight, Kg 330

Page 226
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs 27 Frequency Meter 1
1 Electromechanical unit with flywheel (induction motor, AC machine 102.1, 1 28 Voltage-and-frequency Meter 1
and angular displacement transducer) 29 Synchronous Machine Torque Angle Meter 1
2 Three-phase Power Supply 1 30 Speed Indicator 1
3 Synchronous Machine Exciter 1 31 Power Meter 1
4 Single-phase Power Supply 1 32 Multimeters Module (3 Multimeters) 1
5 Turbine Model Power Supply 1 33 Voltmeter 1
6 Three-pole Breaker 3 34 Voltmeter 1
7 Terminal 1 35 Ammeter 1
8 Active Load 1 36 Three-phase Wattmeter 1
9 Model of ground fault 1 37 Module of Three-phase Single-rate Meter of Active and Reactive 1
10 Transmission Line Model 2 Energy for the Network 100/3 V
11 Line Reactor 1 38 Multifunctional Electric Measurement Device 1
12 Synchronization Module 1 39 Laboratory Table with 2-section Storage Container and 3-level Frame 1
13 Rheostat 1 40 Laboratory Table with Wires Storage Container and 3-level Frame 1
14 Inductive Load 1 41 Laboratory Table with Computer Rack and 3-level Frame 1
15 Model of grounding with vertical tubular electrode 1 42 Accessories Kit 1
16 Connector 1 43 Basic Experiments Guide 1
17 Digital Signals I/O Module 1 44 Basic Experiments Guide 1
18 Three-phase Transformer Group 1 45 Basic Experiments Guide 1
19 Three-phase Transformer Group 1 46 Operation Manual 1
20 Varistors Module 1 47 Didactic and Software CD 1
21 Three-phase two-winding transformer with split low voltage winding 1 48 Personal Computer 1
22 Current-and-voltage Transformers Module 1
23 Current-and-voltage Sensors Module 1
24 Current Transformer 3
25 Voltage Transformer 3
26 Power Factor Meter 1

Page 227
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS b. Determining ratio of short-circuit currents of different faults in the same point in the
network, powered from infinite buses.
3. Basic equipment of electric power stations and substations. c. Short-circuit current limitation.
a. Synchronous generators. i. Limiting short-circuit current by changing output distribution scheme of power
i. Manual / Automatic switching-in synchronous generator for parallel station.
operation by means of self-synchronization. ii. Limiting short-circuit current by network splitting.
ii. Manual / Automatic switching-in synchronous generator for parallel iii. Limiting short-circuit current by network sectionalization.
operation by means of precise synchronization. iv. Limiting short-circuit current by means of line reactor.
iii. Manual / Automated control of synchronous generator mode when v. Limiting short-circuit current by using transformer with low-voltage winding
operating in parallel to infinite bar system. splitted.
iv. Manual / Automatic control of synchronous generator mode when vi. Limiting ground short-circuit current in network with effective neutral
operating in parallel to infinite bar system. grounding by removing transformer neutral grounding.
v. Manual control of mode of autonomously operating synchronous vii. Limiting ground short-circuit current in network with effective neutral
generator. grounding by including reactor into transformer neutral.
vi. Quenching synchronous generator field. 6. Neutral modes in electric installations.
b. Power transformers. a. Modeling neutral modes in electric installation by changing transformer neutral
i. Modeling transformer steady state. reactor reactance; finding dependences of sustained single-phase fault current,
c. Synchronous compensators. unfaulty phase and neutral voltages from reactor reactance.
1.3.1. Start of synchronous compensator and regulation of reactive power. b. Modeling neutral modes in electric installation by changing transformer neutral
4. Auxiliaries of electric power stations and substations. resistance; finding dependences of sustained single-phase fault current, unfaulty
a. Direct-on-line / Reactor start of induction motor. phase and neutral voltages from the resistance.
b. Autostart of induction motor. c. Defining influence of removing transformer neutral on mode of effective neutral
5. Short-circuits in electric installations. grounding in electric installation.
a. Short-circuit current. d. Finding dependences of sustained single-phase fault current, phases voltages
i. Registration and display of current curve of three-phase short circuit from fault resistance in mode of electric installation isolated neutral.
in electric network powered from infinite buses. e. Finding dependences of phase voltages, grounding transformer neutral voltage and
ii. Registration and display of current curve of three-phase short circuit sustained single-phase fault current from fault resistance in mode of electric
in electric network powered from synchronous generator. installation compensated neutral.
f. Finding dependences of phase voltages, grounding transformer neutral voltage and
sustained single-phase fault current from fault resistance in network with resistive
neutral grounding.

Page 228
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1. Earthing arrangements of electric installations.
a. Finding dependence of electric installation base potential from distance to ground (for 5 soil types).
b. Finding dependence of contact voltage from distance to ground (for 5 soil types).
c. Measuring voltages, currents, power, frequency and power factor in three-phase four-wire electric network by shield pointer multifunctional electric measuring device with its direct
connection.
d. Measuring active and reactive power in three-phase AC circuit by electronic counter when connected through measuring current and voltage transformerFinding dependence of
step voltage from distance to ground (for 5 soil types).
2. Electric measurements in electric power stations & substations.
a. Measuring AC current by shield pointer ammeter with its direct connection and connection through measuring current transformer.
b. Measuring AC voltage by shield pointer voltmeter with its direct connection.
c. Measuring AC voltage by shield digit voltmeter with its connection through measuring voltage transformer.
d. Measuring frequency of AC voltage by shield digit frequency indicator with its direct connection and connection through measuring voltage transformer.
e. Measuring active power in three-phase three-wire electric network by pointer shield wattmeter when connected via two current and two voltage measuring transformers.
f. Measuring power factor in three-phase three-wire electric network by shield pointer meter when connected via two current and two voltage measuring transformers.

Page 229
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
11 Electric power systems and grid 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
BASIC EXPERIMENTS EE2M-ESS-S-R Please Contact Us
1. Steady states of electric grid elements. P I C T U R E
1.1. Modeling steady state of three-phase transformer.
1.2. Modeling steady state of three-phase transmission line.
2. Steady states of electric grid.
2.1. Modeling steady state of an electric grid phase with single supply.
2.2. Modeling steady state of an electric grid phase with duplicate supply.
2.3. Modeling steady state of three-phase electric grid with single supply.
3. Steady states of electric power system.
3.1. Consumed active/reactive power effect on electric power system mode.
3.2. Generated active/reactive power effect on electric power system mode.
4. Voltage regulation in grid.
4.1. Counter voltage regulation.
4.2. Voltage regulation by shunt reactive power compensation using capacitor
package.
4.3. Voltage regulation by series reactive power compensation using capacitor
package.

Power consumption, VA 500


Electric supply:
-three-phase AC circuit with
working neutral and protective leads - voltage, V
- single-phase AC circuit with 380 38
working neutral and protective leads
- voltage, V
- frequency, Hertz 220 22
50 0,5
Total dimensions, mm (assembled)
- length 3x910
- width 850
- height 1900
Weight, Kg 250

Page 230
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Components Pcs
1 Electromechanical unit with flywheel (induction motor, AC machine, and 1
angular displacement transducer)
2 Three-phase power supply 1
3 Synchronous machine exciter 1
4 Single-phase power supply 1
5 Turbine model power supply 1
6 Three-pole breaker 1
7 Active load 1
8 Model of transmission line 2
9 Series capacitive compensating device 1
10 Capacitive load 1
11 Inductive load 1
12 Three-phase transformer group 2
13 Three-phase transformer group 1
14 Power meter commutater 2
15 Speed indicator 1
16 Multifunctional electrical measuring instrument 2
17 Laboratory table with 2-level frame 2
18 Laboratory table with 2-section storage container and 2-level frame 1
19 Accessories Kit 1
20 Basic Experiments Guide Electric power systems and grids 1
21 Operation manual 1
22 Didactic materials CD 1

Page 231
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
12 Electric power engineering - Model of single-generator electric 1 Set Unit Prices Total Prices
power system with complex load Type / Model ( Rupiah ) ( Rupiah )
EE2M-N-S-K Please Contact Us
BASIC EXPERIMENTS
P I C T U R E
Electric power stations & substations

7. Basic equipment of electric power stations and substations.


a. Synchronous generators.
i. Manual / Automatic switching-in synchronous generator for parallel
operation by means of self-synchronization.
ii. Manual / Automated switching-in synchronous generator for parallel
operation by means of precise synchronization.
iii. Manual / Automatic switching-in synchronous generator for parallel
operation by means of precise synchronization.

iv. Manual / Automatic control of synchronous generator mode when operating


in parallel to infinite bar system.
v. Manual control of mode of autonomously operating synchronous generator.
vi. Quenching synchronous generator field.
b. Power transformers.
i. Modeling transformer steady state.
c. Synchronous compensators.
1.3.1. Start of synchronous compensator and regulation of reactive power.
8. Auxiliaries of electric power stations and substations.
a. Direct-on-line / Reactor starting of induction motor.
b. Self-starting of induction motor.

Page 232
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Electric power systems and grid Transients in electric power systems

2. Steady states of electric grid elements.. 3. Electromagnetic transients.


4.3. Modeling steady state of three-phase transformer. 3.1. No-load transformer turn-on transient.
4.4. Modeling steady state of three-phase transmission line. 3.2. Symmetrical short-circuit transient in electric network supplied from
5. Steady states of electric grid. infinite bus.
5.1. Modeling steady state of an electric grid phase with single supply. 3.3. Symmetrical short-circuit transient in electric network supplied from
5.2. Modeling steady state of an electric grid phase with duplicate supply. synchronous generator.
5.3. Modeling steady state of three-phase electric grid with single supply. 3.4. Asymmetrical short-circuit transient in electric network supplied from
6. Steady states of electric power system. infinite bus.
6.1. Consumed active/reactive power effect on electric power system mode. 3.5. Loss of single phase transient in electric network supplied from infinite
6.2. Generated active/reactive power effect on electric power system mode. bus.
7. Voltage regulation in grid. 3.6. Line-to-line-to-ground short-circuit transient in electric network with
7.1. Counter voltage regulation. isolated neutral supplied from infinite bus.
7.2. Voltage regulation by shunt reactive power compensation using capacitor 3.7. Single phase short-circuit and loss of single phase transient in electric
package. network with grounded neutral supplied from infinite bus.
7.3. Voltage regulation by series reactive power compensation using capacitor 4. Electromechanical transients.
package. 4.1. Synchronous generator turn-on to electric network transient in single-
Electric power supply machine electric power system.
4.2. Finding synchronous generator power angle characteristics.
4.3. Generator stability loss during its slow loading.
4.4. Transmission line short-circuit transient in single-machine electric power
5. Electroreceiver modes. system.
5.1. Static power - voltage characteristic of resistive load. 4.5. Generator field loss transient in single-machine electric power system.
5.2. Static power - voltage characteristic of inductive load (reactor). 4.6. Short-circuit clearing time limit in single-machine electric power system..
5.3. Static power - voltage characteristic of capacitor bank. 4.7. Synchronous generator resynchronizing transient without field loss in
5.4. Static power - voltage characteristic of lighting load. single-machine electric power system.
5.5. Static power - voltage characteristic of rectifier load.
5.6. Static power - voltage characteristic of induction load.
6. Quality control of electrical energy in power supply systems.
6.1. Measuring parameters of electric energy quality.
6.2. Viewing and registering measured quality parameters of electrical energy using
personal computer.

Page 233
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
6.3. Synchronous generator resynchronizing transient with temporary field loss in single- 3.4.3. Automatic switching-in synchronous generator for parallel
machine electric power system. operation by means of precise synchronization.
Relay protection & Automation of electric power systems 3.5. Automatic regulation of frequency and active power..
3.5.1. Automatic regulation of autonomous generator frequency.
6. Relay protection of electric power systems. 3.5.2. Automatic regulation of active power of generator operating in
6.1. Circuits of measuring transformer. parallel to infinite bus.
6.1.1. Current transformer. 3.6. Automatic regulation of voltage and reactive power.
6.1.2. Voltage transformer. 3.6.1. Automatic regulation of voltage by changing synchronous
6.2. Transmission lines protection. generator excitation.
6.2.1. Transmission line overcurrent protection /Cutoff of two transmission 3.6.2. Induction motor undervoltage protection..
lines with single supply. 4. Automation of normal modes of electric power systems.
6.2.2. Current directional protection of transmission lines in the ring. 4.1. Automatic switching-in synchronous generator for parallel
6.2.3. Protection against ground faults in network with large ground short- operation.
circuit current . 4.1.1. Automatic switching-in synchronous generator for parallel
6.2.4. Nonselective signaling against ground faults in network with small operation by means of self-synchronization.
ground short-circuit current . 4.2. Generator transformer unit protection.
6.2.5. Longitudinal differential protection of transmission lines. 4.2.1. Differential generator transformer unit protection.
6.2.6. Transverse differential protection of parallel transmission lines. 4.3. Induction motor protection.
6.2.7. Distance protection of transmission lines with double supply. 4.3.1. Induction motor overcurrent protection.
6.3. Busbar protection. 4.3.2. Differential induction motor protection..
6.3.1. Differential busbar protection. 4.4. Automatic control of electrical system mode.
6.3.2. Busbar cutoff. 4.4.1. Automatic control of autonomous single-machine electric
6.4. Transformer protection. power system mode.
6.4.1. Differential transformer protection. 4.4.2. Automatic control of mode of single-machine electric power
6.4.2. Transformer overcurrent protection. system operating in parallel to infinite bus.
6.4.3. Transformer reverse-sequence current protection.
6.4.4. Transformer zero-sequence current protection.. 5. Emergency automation of electric power systems.
6.5. Relay protection and circuit breaker back-up. 5.1. Automation of fault clearance, reclosing and back-up switching-
6.5.1. Circuit breaker failure protection. in.
6.6. Synchronous generator protection. 5.1.1. Automatic clearance of short-circuit on transmission line with
6.6.1. Differential generator protection. single supply.
6.6.2. Generator protection against overcurrent and overload. 5.1.2. Automatic prevention of dynamic stability violation by electric
braking of synchronous generator.

Page 234
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
6.6.3. Automatic reclosing of transmission line with single supply. Module / Component Pcs
6.6.4. Automatic reclosing of transmission line with double supply. 1 Electromechanical unit with flywheel (induction motor 101.1, AC 1
6.6.5. Automatic back-up witching-in section switch of step-down substation. machine 102.1, and angular displacement transducer)
6.7. Automatic prevention of instability.
2 Three-phase Power Supply 1
6.7.1. Automatic prevention of dynamic stability violation by synchronous
generator field forcing. 3 DC Motor Power Supply 1
6.7.2. Automatic prevention of dynamic stability violation by quick short-term 4 Synchronous Machine Exciter 1
decrease of synchronous generator primary motor power. 5 Single-phase Power Supply 1
6.8. Automatic termination of asynchronous mode. 6 Three-pole Breaker 6
6.8.1. Automatic terminating asynchronous mode, caused by power line 7 Terminal 1
overloading. 8 Active Load 1
6.8.2. Automatic terminating asynchronous mode, caused by synchronous
9 Transmission Line Model 2
generator field loss.
6.9. Automatic prevention of unacceptable changes of mode parameters. 10 Line Reactor 1
6.9.1. Automatic limitation of voltage drop by switching-in longitudinal 11 Series Capacitive Compensating Device 1
capacitive compensation of power line. 12 Capacitive Load 1
6.9.2. Automatic limitation of voltage rise by switching-in shunt reactor at the 13 Synchronization Module 1
end of power line. 14 Inductive Load 1
15 Connector 1
Power consumption, VA 1000 16 Digital Signals I/O Module 1
Electric supply:
17 Diodes Module 1
- three-phase AC circuit with
working neutral and protective leads 18 Lighting Load 1
voltage, V 380 38 19 Three-phase Transformer Group 2
- single-phase AC circuit with 20 Three-phase Transformer Group 1
working neutral and protective leads 21 Power Meter Commutator 2
voltage, V 220 22 22 Varistors Module 1
- frequency, Hz 50 0,5 23 Adjustable Three-phase Autotransformer 1
Appliance class I
24 Current-and-voltage Transformers Module 2
Total dimensions, mm (assembled)
- length 3910 25 Current-and-voltage Sensors Module 1
- width 850
- height 1900
Weight, Kg 300

Page 235
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
26 Voltage-and-frequency Meter 1
27 Synchronous Machine Torque Angle Meter 1
28 Speed Indicator 1
29 Power Meter 1
30 Multimeters Module (3 Multimeters) 1
31 Electricity Quality Indicators Meter 1
32 Multifunctional Electric Measurement Device 2
33 Laboratory Table with 2-section Storage Container and 3-level Frame 1
34 Storage Rack for Functional Modules 1
35 Laboratory Table with Wires Storage Container and 3-level Frame 1
36 Laboratory Table with Computer Rack and 3-level Frame 1
37 Accessories Kit 1
38 Basic Experiments Guide 1
39 Basic Experiments Guide 1
40 Basic Experiments Guide 1
41 Basic Experiments Guide 1
42 Basic Experiments Guide 1
43 Basic Experiments Guide 1
44 Operation Manual 1
45 Didactic and Software CD 1
46 Personal Computer 1

Page 236
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
13 Electric power engineering - Transients in electric power systems 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
BASIC EXPERIMENTS EE2M-PPES-S-K Please Contact Us
1. Electromagnetic transients. P I C T U R E
1.1. No-load transformer turn-on transient.
1.2. Symmetrical short-circuit transient in electric network supplied from infinite bus.
1.3. Symmetrical short-circuit transient in electric network supplied from synchronous
generator.
1.4. Asymmetrical short-circuit transient in electric network supplied from infinite bus.
1.5. Loss of single phase transient in electric network supplied from infinite bus.
1.6. Line-to-line-to-ground short-circuit transient in electric network with isolated neutral
supplied from infinite bus.
1.7. Single phase short-circuit and loss of single phase transient in electric network with
grounded neutral supplied from infinite bus.
2. Electromechanical transients.
2.1. Synchronous generator turn-on to electric network transient in single-machine
electric power system.
2.2. Finding synchronous generator power angle characteristics.
2.3. Generator stability loss during its slow loading.
2.4. Transmission line short-circuit transient in single-machine electric power system.
2.5. Generator field loss transient in single-machine electric power system.
2.6. Short-circuit clearing time limit in single-machine electric power system..
2.7. Synchronous generator resynchronizing transient without field loss in single-machine
electric power system.
2.8. Synchronous generator resynchronizing transient with temporary field loss in single-
machine electric power system.
2.9. Induction motor turn-on transient.
2.10. Static power - voltage characteristics of load node.
2.11. Induction motor active power torque characteristic.
2.12. Finding induction motor minimal voltage.
2.13. Induction motor temporary power outage transient.

Page 237
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs 25 Current-and-voltage Sensors Module 1
1 Electromechanical unit with flywheel (DC machine 101.1, AC machine 1 26 Voltage-and-frequency Meter 1
102.1, and angular displacement transducer) 27 Synchronous Machine Torque Angle Meter 1
2 Electromechanical unit (with electrodynamic brake 110, induction motor 1 28 Speed Indicator 2
106 and angular displacement transducer) 29 Power Meter 1
3 Three-phase Power Supply 1 30 Multimeters Module (3 Multimeters) 1
4 DC Motor Power Supply 1 31 Laboratory Table with 2-section Storage Container and 3-level Frame 1
5 Synchronous Machine Exciter 1 32 Laboratory Table with Wires Storage Container and 3-level Frame 1
6 DC Voltage Source 1 33 Laboratory Table with Computer Rack and 3-level Frame 1
7 Single-phase Power Supply 1 34 Accessories Kit 1
8 Three-pole Breaker 4 35 Basic Experiments Guide 1
9 Terminal 1 36 Operation Manual 1
10 Active Load 1 37 Didactic and Software CD 1
11 Transmission Line Model 2 38 Personal Computer 1
12 Line Reactor 1
13 Capacitive Load 1
2.1. Power consumption, VA 1000
14 Adjustable Autotransformer 1
2.2. Electric supply:
15 Synchronization Module 1 - three-pha`se AC circuit with
16 Inductive Load 1 working neutral and protective leads voltage, V
17 Connector 1 - single-phase AC circuit withworking neutral and protective 380
18 Digital Signals I/O Module 1 leads voltage, V 38
19 Diodes Module 1 - frequency, Hz
20 Lighting Load 1
220
21 Three-phase Transformer Group 1 22
22 Three-phase Transformer Group 1 50 0,5
23 Adjustable Three-phase Autotransformer 1 2.4. Total dimensions, mm (assembled)
24 Current-and-voltage Transformers Module 1 - length 3910
- width 850
- height 1900
2.5. Weight, Kg 350

Page 238
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
14 Relay protection and automation of electric power systems 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
BASIC EXPERIMENTS
EE2M-RZAES-S-K Please Contact Us
1.1. Relay protection of electric power systems. P I C T U R E
1.1.1. Schemes of measuring transformers connection.
1.1.2. Schemes of current transformers connection.
1.1.3. Schemes of voltage transformers connection..
1.2. Protection of transmission lines.
1.2.1. Overcurrent protection / cutoff of two transmission lines with single
supply.
1.2.2. Directional current protection of transmission lines in ring grid.
1.2.3. Ground fault protection of grid with big ground fault current.
1.2.4. Nonselective alarm of ground fault in grid with small ground fault
current.
1.2.5. Longitudinal differential protection of transmission line.
1.2.6. Transverse differential protection of parallel transmission lines..
1.2.7. Distance protection of transmission lines in grid with duplicate supply.
1.3. Busbar protection.
1.3.1. Differential busbar protection.
1.3.2. Current busbar cutoff.
1.3.3. Distance busbar protection.
1.4. Power transformer protection.
1.4.1. Differential transformer protection.
1.4.2. Overcurrent transformer protection.
1.4.3. Negative phase-sequence transformer current protection.
1.4.4. Zero-sequence transformer current protection.
1.5. Relay protection and breakers back-up.
1.5.1. Circuit-breaker failure protection.
1.6. Synchronous generator protection.
1.6.1. Differential generator protection.
1.6.2. Overcurrent and overload generator protection.
1.7. Generator-transformer unit protection.
1.7.1. Differential generator-transformer unit protection.

Page 239
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
6.1. Induction motor protection. 7.2.2.Automatic control of dynamic stability by quick short-time
6.1.1. Overcurrent induction motor protection. synchronous generator prime mover power reduction.
6.1.2. Differential induction motor protection. 7.2.3. Automatic control of dynamic stability by synchronous generator
6.1.3. Low-voltage induction motor protection. electric braking.
6.1.4. Automation of electric power systems normal modes. 7.3. Automatic asynchronous mode prevention.
6.1.5. Automatic switching-in synchronous generator in parallel. 7.3.1. Automatic prevention of asynchronous mode caused by transmission
6.1.6. Automatic switching-in synchronous generator in parallel by self- line overload.
synchronization. 7.3.2. Automatic prevention of asynchronous mode caused by synchronous
6.1.7. Automatic switching-in synchronous generator in parallel by ideal generator field loss.
synchronization. 7.4. Automatic prevention of unacceptable changes of regime parameters.
6.1.8. Frequency and active power automatic control. 7.4.1. Automatic compensation of transmission line.
6.1.9. Autonomous electric power system frequency automatic 7.4.2. Automatic voltage rise limitation by shunt reactor at transmission line
regulation. end.
6.1.10. Active power automatic control of synchronous generator working 7.4.3. Automatic frequency drop limitation by electric power system load
in parallel to infinite bus.. switching-off.voltage drop limitation by series capacitive
6.1.11. Voltage and reactive power automatic control.
6.1.12. Voltage automatic regulation by synchronous generator field
Power consumption, VA 1000
changing.
Electric supply:
6.1.13. Voltage automatic regulation by static thyristor compensator
-three-phase AC circuit with
reactive power changing.
6.2. Automatic control of electric power system mode. working neutral and protective leads
- voltage, V 380 38
6.2.1. Automatic control of autonomous single-machine electric power
- single-phase AC circuit with
system mode..
working neutral and protective leads
6.2.2. Automatic control of mode of single-machine electric power
- voltage, V 220 22
system operating in parallel to infinite bus.
7. Emergency automation of electric power systems. - frequency, Hertz 50 0,5
7.1. Automation of fault clearing, reclosing and back-up switching. Appliance class I
Total dimensions, mm (assembled)
7.1.1. Automatic fault clearing on transmission line with single supply.
- length 3x910
7.1.2. Automatic reclosing transmission line with single supply.
- width 850
7.1.3. Automatic reclosing transmission line with duplicate supply.
- height 1900
7.1.4. Automatic switching-in step-down substation section switch.
7.2. Automatic stability control.
7.2.1. Automatic control of dynamic stability by synchronous generator

Page 240
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
24 Module of current-and-voltage sensors 1
Module / Component Pcs 25 Voltage-and-frequency meter 1
1 Electromechanical unit with flywheel (induction motor, AC machine, and 1 26 Synchronous machine torque angle meter 1
angular displacement transducer) 27 Speed indicator 2
2 Electromechanical unit (electromagnetic brake, induction motor, and 1 28 Power meter 1
angular displacement transducer) 29 Laboratory table with 2-section storage container and 3-level frame 1
3 Three-phase power supply 1 30 Laboratory table with storage container for wires and 3-level frame 1
4 Thyrister converter/regulator 1 31 Laboratory table with computer rack and pullout keyboard shelf and 3- 1
5 Synchronous machine exciter 1 level frame
6 DC voltage source 1 32 Accessories Kit 1
7 Single-phase power supply 1 33 Basic Experiments Guide Relay protection of electric power systems 1
8 Turbine model power supply 1 34 Basic Experiments Guide Automation of electric power systems 1
9 Three-pole breaker 6 35 Operation manual 1
10 Terminal 1 36 Didactic materials and Software CD 1
11 Active load 1 37 Personal computer 1
12 Model of transmission line 2
13 Line reactor 1
14 Series capacitive compensating device 1
15 Capacitive load 1
16 Module of synchronizing 1
17 Inductive load 1
18 Connector 1
19 Module of digital signals input/output 1
20 Module of diodes 1
21 Three-phase transformer group 2
22 Three-phase transformer group 1
23 Module of current-and-voltage transformers 2

Page 241
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
15 Electric power engineering - Electric power stations & 1 Set Unit Prices Total Prices
substations Type / Model ( Rupiah ) ( Rupiah )
BASIC EXPERIMENTS Please Contact Us
3. Basic equipment of electric power stations and substations.
EE3M-ESP-S-K
a. Synchronous generators. P I C T U R E
i. Manual / Automatic switching-in synchronous generator for parallel operation
by means of self-synchronization.
ii. Manual / Automated switching-in synchronous generator for parallel operation
by means of precise synchronization.
iii. Manual / Automatic switching-in synchronous generator for parallel operation
by means of precise synchronization.

iv. Manual / Automatic control of synchronous generator mode when operating in


parallel to infinite bar system.
v. Manual control of mode of autonomously operating synchronous generator.
vi. Quenching synchronous generator field.
b. Power transformers.
i. Modeling transformer steady state.
c. Synchronous compensators.
1.3.1. Start of synchronous compensator and regulation of reactive power.
4. Auxiliaries of electric power stations and substations.
a. Direct-on-line / Reactor start of induction motor.
b. Autostart of induction motor.
5. Short-circuits in electric installations.
a. Short-circuit current.
i. Registration and display of current curve of three-phase short circuit in electric
network powered from infinite buses.
ii. Registration and display of current curve of three-phase short circuit in electric
network powered from synchronous generator.
Determining ratio of short-circuit currents of different faults in the same point in the network,
powered from infinite buses
a. Short-circuit current limitation.
iii. Limiting short-circuit current by changing output distribution scheme of power
station.

Page 242
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
i. Limiting short-circuit current by network splitting. 9. Electric measurements in electric power stations & substations.
ii. Limiting short-circuit current by network sectionalization. a. Measuring AC current by shield pointer ammeter with its direct connection
iii. Limiting short-circuit current by means of line reactor. and connection through measuring current transformer.
iv. Limiting short-circuit current by using transformer with low-voltage winding b. Measuring AC voltage by shield pointer voltmeter with its direct connection.
splitted. c. Measuring AC voltage by shield digit voltmeter with its connection through
v. Limiting ground short-circuit current in network with effective neutral grounding measuring voltage transformer.
by removing transformer neutral grounding. Measuring frequency of AC voltage by shield digit frequency indicator with its direct
vi. Limiting ground short-circuit current in network with effective neutral grounding connection and connection through measuring voltage transformer
by including reactor into transformer neutral. a. Measuring active power in three-phase three-wire electric network
by pointer shield wattmeter when connected via two current and two
11. Neutral modes in electric installations. voltage measuring transformers.
a. Modeling neutral modes in electric installation by changing transformer neutral b. Measuring power factor in three-phase three-wire electric network
reactor reactance; finding dependences of sustained single-phase fault current, by shield pointer meter when connected via two current and two
unfaulty phase and neutral voltages from reactor reactance. voltage measuring transformers.
b. Modeling neutral modes in electric installation by changing transformer neutral c. Measuring voltages, currents, power, frequency and power factor in
resistance; finding dependences of sustained single-phase fault current, unfaulty three-phase four-wire electric network by shield pointer
phase and neutral voltages from the resistance. multifunctional electric measuring device with its direct connection.
c. Defining influence of removing transformer neutral on mode of effective neutral d. Measuring active and reactive power in three-phase AC circuit by
grounding in electric installation. electronic counter when connected through measuring current and
d. Finding dependences of sustained single-phase fault current, phases voltages from voltage transformers.
fault resistance in mode of electric installation isolated neutral. 10. Measuring transformers.
e. Finding dependences of phase voltages, grounding transformer neutral voltage and a. Determination of measuring current transformer error.
sustained single-phase fault current from fault resistance in mode of electric b. Determination of measuring voltage transformer error.
installation compensated neutral.
f. Finding dependences of phase voltages, grounding transformer neutral voltage and
sustained single-phase fault current from fault resistance in network with resistive
neutral grounding.
12. Grounding arrangements of electric installations.
a. Finding dependence of electric installation base potential from distance to ground
(for 5 soil types).
b. Finding dependence of contact voltage from distance to ground (for 5 soil types).
c. Finding dependence of step voltage from distance to ground (for 5 soil types).
d. .

Page 243
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs 27 Voltage Transformer 3
1 Electromechanical unit with flywheel (induction motor, AC machine 1 28 Power Factor Meter 1
102.1, and angular displacement transducer) 29 Frequency Meter 1
2 Three-phase Power Supply 1 30 Voltage-and-frequency Meter 1
3 Synchronous Machine Exciter 1 31 Synchronous Machine Torque Angle Meter 1
4 Single-phase Power Supply 1 32 Speed Indicator 1
5 Turbine Model Power Supply 1 33 Power Meter 1
6 Three-pole Breaker 3 34 Multimeters Module (3 Multimeters) 1
7 Terminal 1 35 Voltmeter 1
8 Active Load 1 36 Voltmeter 1
9 Model of ground fault 1 37 Ammeter 1
10 Transmission Line Model 2 38 Three-phase Wattmeter 1
11 Line Reactor 1 39 Module of Three-phase Single-rate Meter of Active and Reactive Energy for 1
12 Adjustable Autotransformer 1 the Network 100/3 V
13 Synchronization Module 1 40 Multifunctional Electric Measurement Device 1
14 Rheostat 1 41 Laboratory Table with 2-section Storage Container and 3-level Frame 1
15 Inductive Load 1 42 Laboratory Table with Wires Storage Container and 3-level Frame 1
16 Model of grounding with vertical tubular electrode 1 43 Laboratory Table with Computer Rack and 3-level Frame 1
17 Connector 1 44 Storage Rack for Functional Modules 1
18 Digital Signals I/O Module 1 45 Accessories Kit 1
19 Three-phase Transformer Group 1 46 Basic Experiments Guide 1
20 Three-phase Transformer Group 1 47 Basic Experiments Guide 1
21 Varistors Module 1 48 Basic Experiments Guide 1
22 Three-phase two-winding transformer with split low voltage winding 1 49 Operation Manual 1
23 Current-and-voltage Transformers Module 1 50 Didactic and Software CD 1
24 Current-and-voltage Sensors Module 1 51 Personal Computer 1
25 Current Transformer 3
26 Voltage Transformer 1

Page 244
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
2.1. Power consumption, VA 1000
2.2. Electric supply:
- three-phase AC circuit with
working neutral and protective leads
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
2.3. Appliance class I
2.4. Total dimensions, mm (assembled)
- length 3910
- width 850
- height 1900
2.5. Weight, Kg 330

Page 245
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
16 Electric power stations and substations 1 Set Unit Prices Total Prices
Power consumption, VA 1000 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
-three-phase AC circuit with EE4M-ESP-S-K Please Contact Us
working neutral and protective leads P I C T U R E
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 3x910
- width 850
- height 1900
Power consumption, VA 1000

BASIC EXPERIMENTS

1. Main equipment of electric power stations and substations.


a. Synchronous generators.
i. Hand / automatic control of switching synchronous generator on parallel
operation by coarse synchronization.
ii. Hand / automatic control of switching synchronous generator on parallel
operation by ideal synchronization.

Page 246
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
c. Power transformers. . e. Effect of switching-off transformer neutral on effective neutral grounding in
i. Modeling transformer steady state. electric installation.
d. Synchronous compensators. f. Steady-state single-phase short-circuit current, phase voltages VS short-circuit
1.3.1. Synchronous compensator start-up and reactive power regulation. resistance at insulated electric installation neutral.
15. Auxiliary needs of electric power stations and substations. g. Phase voltages, grounding transformer neutral voltage, steady-state single-
a. Direct-on-line / reactor start of induction motor. phase short-circuit current VS short-circuit resistance at compensated electric
b. Self-running of induction motor. installation neutral.
16. Short-circuits in electric installations. h. Phase voltages, grounding transformer neutral voltage, steady-state single-
a. Short-circuit currents. phase short-circuit current VS short-circuit resistance in grid with neutral
i. Record of three-phase short-circuit currents in electric grid supplied by almost infinite bus. resistive grounding.
ii. Record of three-phase short-circuit currents in electric grid supplied by synchronous generator of 13. Electric installation groundings.
limited power. . a. Electric installation base neutral potential VS distance to grounding (for 5 types
iii. Ratio of short-circuit currents of various kinds in the same point of grid supplied by almost infinite of ground.
bus. b. Touch voltage VS distance to grounding (for 5 types of ground).
b. Short-circuit currents limiting. c. Step voltage VS distance to grounding (for 5 types of ground).
i. Short-circuit current limiting by changing power output scheme of electric power station. 14. Electric measurements at electric power stations and substations.
ii. Short-circuit current limiting by grid splitting. a. AC current measurement by switchboard ammeter direct connection and
iii. Short-circuit current limiting by grid islanding. connection through current transformer.
iv. Short-circuit current limiting by using line reactor. b. AC voltage measurement by switchboard voltmeter direct connection.
v. Short-circuit current limiting by using transformer with split lower-voltage winding.
vi. Ground short-circuit current limiting in grid with effective neutral ground by switching-off
transformer neutral.
vii. Ground short-circuit current limiting in grid with effective neutral ground by switching-in reactor in
transformer neutral.
17. Neutral modes in electric installations.
a. Modeling electric installation neutral modes by changing inductive reactance of transformer neutral
reactor. Steady-state single-phase short-circuit current, transformer intact phase and neutral
voltages VS reactance of transformer neutral reactor.
b. Modeling electric installation neutral modes by changing transformer neutral resistor. Steady-state
single-phase short-circuit current, transformer intact phase and neutral voltages VS transformer
neutral resistor.

Page 247
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
c. AC voltage measurement by switchboard digital voltmeter - Module / Component Pcs
1 Electromechanical unit with flywheel (induction motor, AC machine, and angular 1
connection through voltage transformer. .
displacement transducer)
d. Frequency measurement by switchboard frequency meter 2 Three-phase power supply 1
direct connection and connection through voltage 3 Synchronous machine exciter 1
transformer. 4 Single-phase power supply 1
5 Turbine model power supply 1
e. Active power measurements in 3-phase 3-wire mains by
6 Three-pole breaker 3
switchboard wattmeter connection through 2 current 7 Model of transmission line section 1
transformers and 2 voltage transformers. 8 Terminal 1
f. Power factor measurements in 3-phase 3-wire mains by 9 Active load 1
switchboard meter connection through 2 current 10 Model of ground fault 1
11 Model of insulation resistance 1
transformers and 2 voltage transformers. 12 Model of transmission line 2
g. AC voltage, current, power, frequency and power factor 13 Line reactor 1
measurements in 3-phase 4-wire mains by multifunctional 14 Insulation monitoring device 1
electrical measuring instrument direct connection. 15 Adjustable autotransformer 1
16 Module of synchronizing 1
h. Active and reactive power measurements in 3-phase mains by
17 Rheostat 1
electronic meter connection through current and voltage 18 Inductive load 1
transformers. 19 Model of grounding with vertical tubular electrode 1
18. Measuring transformers. 20 Connector 1
21 Module of digital signals input/output 1
a. Measurement error of current transformer.
22 Three-phase transformer group 1
b. Measurement error of voltage transformer. 23 Three-phase transformer group 1
24 Module of varistors 1
25 Three-phase two-winding transformer with split lower-voltage winding 1

Page 248
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
26 Module of current-and-voltage transformers 1
27 Module of current-and-voltage sensors 1
28 Current transformer 3
29 Voltage transformer 1
30 Voltage transformer 3
31 Power factor meter 1
32 Frequency meter 1
33 Voltage-and-frequency meter 1
34 Synchronous machine torque angle meter 1
35 Speed indicator 1
36 Power meter 1
37 Module of 3 multimeters 1
38 Voltmeter 1
39 Voltmeter 1
40 Ammeter 1
41 Three-phase wattmeter 1
42 Module of three-phase single-rate meter of active and reactive energy for the network 100/3 V 1
43 Multifunctional electrical measuring instrument 1
44 Laboratory table with 2-section storage container and 3-level frame 1
45 Laboratory table with storage container for wires and 3-level frame 1
46 Laboratory table with computer rack and pullout keyboard shelf and 3-level frame 1
47 Storage rack for functional modules 1
48 Accessories Kit 1
49 Basic Experiments Guide Electric measurements in electric power stations and substations 1
50 Basic Experiments Guide Electric power stations and substations 1
51 Basic Experiments Guide Insulation monitoring in electric installations with small ground short-circuit current 1
52 Basic Experiments Guide Neutral modes and groundings in electric installations 1

Page 249
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
17 Electrical And Magnetic Circuits, Fundamentals 1 Set Unit Prices Total Prices
Of Electronics Labware Set Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA, not more than 50 EMCOE1-N-R Please Contact Us
Electrical supply:
- single-phase AC circuit with P I C T U R E
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Class of protection against electrical shock I
Overall dimensions, mm, not more than
- length 910
- width 500
- height 400
Weight, Kg, not more than 15

Name Pcs
1 Voltage generators & testing board 1
2 Single-phase power supply 1
3 Long-distance line model 1
4 Two multimeters module 1
5 Wattmeter 1
6 Set of minimodules Digital electronics fundamentals 1
7 Set of minimodules Analog electronics Electrical components 1
8 Set of minimodules Analog electronics Electronic components 1
9 Set of minimodules Electromagnetic components 1
10 Single-level frame with container (length 910 mm) 1
12 Set of accessories 1
13 Two-channel oscilloscope 1

Page 250
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
List of basic experiments: 1.1.
Electrical and magnetic circuits 2. Distributed-element circuits.
4. Linear DC circuits. 2.1. Voltage distribution along homogeneous long-distance transmission line.
4.1. Measurements of resistance, current, voltage and electrical power in DC circuits. 2.2. Input resistance of long-distance transmission line as function of its
4.2. Series connection of resistors. electrical length and load resistance.
4.3. Parallel connection of resistors. 2.3. Reflected waves.
4.4. Series-parallel connection of resistors. 3. Nonlinear electric and magnetic circuits.
4.5. Power transmission from active two-pole circuit to load. 3.1. Volt-ampere characteristics of nonlinear elements in DC circuit.
5. AC circuits. 3.2. Linearized parameters of bipolar transistor.
5.1. Series connection of elements R, L and (sinusoidal current). 3.3. DC Magnetic circuits.
5.2. Frequency characteristics of series resonant circuit. 3.4. AC Magnetic circuits.
5.3. Parallel connection of inductance and capacitor. 3.5. Resonance in series circuit of nonlinear inductor and capacitor.
5.4. Frequency characteristics of parallel resonant circuit. 3.6. Test of single-phase transformer.
5.5. Parameters of inductively connected coils. 3.7. Single-phase rectifier.
5.6. Circuits with nonsinusoidal applied voltage. Fundamentals of electronics
6. Three-phase circuits. Fundamentals of analog electronics
6.1. Star connection of three-phase electrical load. 1. Semiconductors.
6.2. Delta connection of three-phase electrical load. 1.1. Characteristics of semiconductor diodes for direct and alternating
6.3. Failure modes of three-phase circuit with load connected star. currents.
6.4. Failure modes of three-phase circuit with load connected delta. 1.2. Main characteristics of stabilitron and study of parametric voltage
6.5. Voltage negative-phase sequence filter (NPSF). regulator.
7. Transients in linear electrical circuits. 1.3. Current-voltage characteristics of LED.
7.1. Charge and discharge of capacitor. 1.4. Variable capacitance diode (varicap).
7.2. Switching-in and fault in circuit with inductor. 1.5. Test of p-n junctions of bipolar transistor and receiving its output
7.3. Transients in circuit with resistors and capacitor. characteristics with an oscilloscope.
7.4. Switching-on and switching-off circuit with inductor. 1.6. Static characteristics of transistor for direct current.
7.5. Transients in R-L-C circuit. 1.7. Choice of bipolar transistor operating point and familiarization with AC
8. Quadripoles. voltage amplification mode of classes A, B, AB, and D.
8.1. Parameters of passive quadripole. 1.8. Static characteristics of a field-effect transistor with p-n junction.
8.2. Frequency characteristics of quadripole (low-pass filter). 1.9. Static characteristics of field-effect transistor, insulated gate
8.3. Simplest integral and differential quadripoles.

Page 251
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.10. Main characteristics of thyristors. 2. Assembly and test of simple combinational nodes of digital devices.
1.11. Basic characteristics and parameters of photocouplers. 2.1. Combinational node using basic logic elements to implement arbitrary logic
2. Electronic circuits and microcircuitry. function.
2.1. Comparative study of single amplifier stages using bipolar transistors. 2.2. Combinational nodes using basic logic elements for experimental
2.2. Study of the amplifier stages using FET. confirmation of logic algebra laws.
2.3. Study of two-stage transistor amplifier. 3. Assembly and test of sequential nodes of digital devices.
2.4. Study of push-pull power amplifier using bipolar transistors. 3.1. Triggers.
3.2. Counters
2.5. Basic circuits of operational amplifiers.
2.6. Frequency characteristics of operational amplifiers
2.7. Summing, integrating and differentiating operational amplifiers.
2.8. RC-filter using operational amplifier.
2.9. Simple logarithmic converter using operational amplifier.
2.10. Generator of sinusoidal oscillations using operational amplifier.
2.11. Schmitt trigger and relaxation oscillators using operational amplifier.
2.12. RS-trigger, multivibrator and single-shot trigger.
2.13. Analog integrated comparators and circuits with them.
2.14. Self-oscillating and standby modes of analog timer using integrated chip.

3. Stabilizers and secondary sources of supply.


3.1. Half-wave and bridge-circuit rectifiers.
3.2. Three-phase bridge-circuit rectifier and smoothing filters.
3.3. Controlled rectifiers and thyrister regulator with phase control.
3.4. Degenerative voltage and current stabilizers.
3.5. Main schemes of coupling linear integral voltage regulator.
3.6. PWM DC-DC converter.
3.7. Integral pulse converter - voltage stabilizer with pulse-frequency modulation.

Fundamentals of digital electronics

1. Testing basic logic elements.

Page 252
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
18 Wiring in residential and office premises 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
EMJP1-N-R Please Contact Us
Ordering Information
BASIC EXPERIMENTS
1. Assembling and check of electrical switchboard
circuits of residential and office premises.
1.1. Circuits of apartment switchboard with two-wire
electric network and protective switching device
(RCCB).
1.2. Circuits of standart apartment switchboard with
grounding system TN-C-S.
1.3. Circuits of luxury apartment switchboard with
grounding system TN-C-S.
1.4. Circuits of office switchboard with grounding
system TN-C-S.
2. Assembling and test of electrical lighting circuits.
2.1. Switching circuits of incandescent lamps.
2.2. Switching circuit of luminescent lamps.
2.3. Lighting control circuits.
3. Assembling and testing of group electric networks
of residential and office premises.
3.1. Group two-wire electric network of apartment
room lighting and sockets with protective
switching device (RCCB).
3.2. Group electric network of hallway, bathroom and
toilet rooms lighting, and electric bell in standard
apartment with grounding system TN-C-S.
3.3. Group electric network of hallway and kitchen
sockets in standart apartment with grounding
system TN-C-S.
3.4. Group electric network of bathroom and toilet r

Page 253
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.1. ooms lighting and sockets in luxury apartment with grounding system TN-C-S.
1.2. Group electric network of office lighting and sockets with grounding system TN-C- Module / Component Pcs
S. 1 Single-phase Power Supply 1
Power consumption, VA 100 2 Electric Supply Grid Model 1
Electric supply: 3 Double-pole Switch 1
- - single-phase AC circuit with
4 Residual Current Devices Module 1
working neutral and protective leads
voltage, V 220 22 5 Automatic Breakers Module 1
- frequency, Hz 50 0,5 6 One-button Switch 1
Appliance class I 7 Double-button Switch 1
Total dimensions, mm (assembled) 8 Toggle Switch 2
- length 2920 9 Electric Socket w/o Grounding Contact 2
- width 350 10 Electric Socket with Grounding Contact 3
- height 800
11 Electric Socket with Grounding Contact 1
Weight, Kg 20
12 Distribution Box 1
13 Incandescent Lamp 3
14 Bell Button 1
15 Electric Bell 1
16 Dimmer 1
17 Fluorescent Lamp Module 1
18 Electricity Meter 1
19 Two-level Desktop Frame with Container 1
20 Single-level Desktop Frame with Container (length 910 mm) 1
21 Accessories Kit 1
22 Basic Experiments Guide 1
23 Operation Manual 1
24 Didactic Materials CD 1

Page 254
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
19 Electric machines and drives 1 Set Unit Prices Total Prices
BASIC EXPERIMENTS Type / Model ( Rupiah ) ( Rupiah )
Electric machines EMP1M-S-R Please Contact Us
P I C T U R E
1. Single-phase transformer.
1.1. Transformation ratio of single-phase transformer.
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase transformer.
1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) single-phase transformer.
1.4. Characteristic U = f (I) single-phase transformer with resistive load.
1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of single-
phase transformer with a resistive load.
1.6. Determination of equalizing current caused by inequality of transformation ratios of parallel
single-phase transformers.
1.7. Effect caused by the inequality of short-circuit voltages of single-phase transformers
operating in parallel.
2. Single-phase autotransformer.
2.1. Transformation ratio of single-phase autotransformer.
2.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) of single-phase
autotransformer.
2.3. Characteristic U = f (I) single-phase during resistive load.
3. Three-phase transformer.
3.1. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of three-phase transformer.
3.2. Short-circuit characteristics IK = f (U), RC = f (U), cosK = f (U) t of three-phase
transformer.
3.3. Checking vector grouping of three-phase transformer.
3.4. Confirmation of impossibility of parallel operation of three-phase transformers with
different vector grouping.
4. DC generators with separate / shunt excitation.
4.1. Idling characteristics E0 = f (If) of DC generator with separate excitation.
4.2. Short-circuit characteristics IK = f (If) of DC generator with separate excitation.
4.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with separate excitation.
4.4. Characteristic U = f (I) of DC generator with shunt excitation

Page 255
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
4. DC motors with separate / shunt / series excitation.
5.1. Electromechanical (speed) characteristics n = f (I) of DC motor with independent / 1. Electric drive using DC motor with separate (shunt, series) excitation.
shunt / series excitation. 2.1 Determination of electromechanical and mechanical characteristics of electric
5.2. Mechanical characteristics of n = f (M) of DC motor with an separate / shunt/ series drive in motor, generator, and braking modes.
excitation. 2.2. Speed control by changing resistance in armature circuit of DC motor.
5.3. Operational characteristics n = f (P2), P1 = f (P2), M = f (P2), = f (P2) of DC motor 2.3. Speed control by changing excitation current of DC motor.
with separate / shunt/ series excitation. 2.4. Speed control by shunting field winding of DC motor with series excitation.
5.4. Speed control of DC motor with separate / shunt/ series excitation by armature 2.5. Speed control by changing armature voltage DC motor.
voltage changing. 2.6. Definition of energy parameters of electric drive with DC motor.
5.5. Speed control of a DC motor with separate / shunt / series excitation by changing 2.7. Measuring body temperature of DC motor.
additional resistance in the armature circuit. 33. Electric drive using squirrel-cage induction motor.
5.6. Speed control of a DC motor with separate / shunt excitation by field current change. 3.1. Electromechanical and mechanical characteristics of electric drive with
5.7. Speed control motor with series excitation by shunting field winding.. induction motor in motor, generator, and braking modes.
6. Three-phase squirrel-cage induction motor. 3.2. Speed control by match changing frequency and magnitude of stator
6.1. Idling characteristics I0 = f (U), P0 = f (U), cos0 = f (U) . voltage .
6.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) . 3.3. Stator current and speed as function of time during transient.
6.3. Electromechanical (speed) characteristic n = f (I). 3.3. Definition of energy parameters of electric drive with induction motor .
6.4. Mechanical characteristic n = f (M). 3.4. Measurement of body temperature of induction motor.
6.5. Operational characteristics I = f (P2), P1 = f (P2), s = f (P2), = f
(P2),
cos = f (P2), M = f (P2).
6.6. Speed control of three-phase squirrel-cage induction motor by stator
voltage changing.

2. Electric drives

1. Mechanics of drives.
1.1. Determination of inertia moment of electric drive by method of free run-out.
1.2. Determination of mechanical characteristic of working mechanism.

Page 256
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Power consumption, VA 500 Module / Component Pcs
Electric supply: 1 Electromechanical unit with flywheel (with DC machine, induction motor 106, and 1
- three-phase AC circuit with
angular displacement transducer)
working neutral and protective leads
voltage, V 380 38 2 Three-phase Power Supply 1
- single-phase AC circuit with 3 Single-Phase Thyristor Converter 1
working neutral and protective leads 4 Frequency onverter 1
voltage, V 220 22 5 Single-phase Power Supply 1
- frequency, Hz 50 0,5 6 Three-pole Breaker 1
Appliance class I 7 Active Load 1
Total dimensions, mm (assembled)
- length 2910 8 DC Machine Excitation Rheostat 1
- width 850 9 Line Reactor 1
- height 1600 10 Adjustable Autotransformer 1
Weight, Kg 150 11 Rectifier 1
12 Rheostat 1
13 Three-phase Transformer Group 2
14 Adjustable Three-phase Autotransformer 1
15 Speed Indicator 1
16 Multimeters Module (2 Multimeters) 1
17 Voltammeter 1
18 Multifunctional Electric Measurement Device 1
19 Laboratory Table with 2-section Storage Container and 2-level Frame 1
20 Laboratory Table with storage container and 2-level frame 1
21 Accessories Kit 1
22 Basic Experiments Guide 1
23 Basic Experiments Guide 1
24 Operation Manual 1
25 Stopwatch 1

Page 257
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
20 Electric machines and drives 1 Set Unit Prices Total Prices
Power consumption, VA 200 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
- single-phase AC circuit with EMP2M-S-R Please Contact Us
working neutral and protective leads P I C T U R E
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1600
Weight, Kg 75
Module / Component Pcs
1 Electromechanical Unit (DC Machine 101.1, Induction Motor 106 and 1
Angular Displacement Transducer)
2 Frequency onverter 1
3 Single-phase Power Supply 1
4 Active Load 1
5 DC Machine Excitation Rheostat 1
6 Adjustable Autotransformer 1
7 Rectifier 1
8 Single-phase Transformer 1
9 Speed Indicator 1
10 Multimeters Module (3 Multimeters) 1
11 Voltammeter 1
12 Single-phase Network Parameters Meter 1
13 Laboratory Table with 2-section Storage Container and 2-level Frame 1
14 Accessories Kit 1

Page 258
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
BASIC EXPERIMENTS

1. Single-phase transformer.
1.1. Transformation ratio of single-phase transformer.
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase transformer.
1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) single-phase transformer.
1.4. Characteristic U = f (I) single-phase transformer with resistive load.
1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of single-phase transformer with a resistive load.
2. DC generators with separate excitation.
2.1. Idling characteristics E0 = f (If) of DC generator with separate excitation.
2.2. Short-circuit characteristics IK = f (If) of DC generator with separate excitation.
2.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with separate excitation.
3. DC motor with shunt excitation and drives on its bases.
3.1.Electromechanical (speed) characteristics n = f (I) of DC motor shunt excitation.
3.1. Mechanical characteristics of n = f (M) of DC motor with shunt excitation.
3.2. Speed control of DC motor with shunt excitation by armature voltage changing.
3.3. Speed control of a DC motor with shunt excitation by field current change.
3.4. Determining coordinates of electric drive with DC shunt motor in generator, engine and braking modes.
4. Three-phase squirrel-cage induction motor and drives on its bases.
4.1. Electromechanical (speed) characteristic n = f (I).
4.2. Mechanical characteristic n = f (M).
4.3. . Speed control by match changing frequency and magnitude of stator voltage.
4.4. Determining coordinates of electric drive with induction squirrel-cage motor in generator, engine and braking modes.

Page 259
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
21 Electric machines and drives 1 Set Unit Prices Total Prices
Power consumption, VA 500 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
- three-phase AC circuit with EMP3M-S-K Please Contact Us
working neutral and protective leads P I C T U R E
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 3910
- width 850
- height 1600
Weight, Kg 200
BASIC EXPERIMENTS
Electric machines

1. Single-phase transformer and autotransformer.


1.1. Transformation ratio of single-phase transformer.
1.2. Idling characteristics I0 = f (U), F0 = f (U), cos0 = f (U) of single-phase transformer.
1.3. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) single-phase
transformer.
1.4. Characteristic U = f (I) single-phase transformer with resistive load.
1.5. Operational characteristics I1 = f (P2), P1 = f (P2), = f (P2), cos = f (P2) of single-
phase transformer with a resistive load.
1.6. Transformation ratio of single-phase autotransformer..
1.7. Idle characteristics I0=f(U), 0=f(U), cos0= f(U) of single-phase
autotransformer.
1.8. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) of
single-phase autotransformer.

Page 260
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.6. Characteristic U = f (I) of single-phase autotransformer during resistive 5.1. Switching-in three-phase synchronous generator to grid by ideal
load. synchronization.
2. DC generators. 5.2. Switching-in three-phase synchronous generator to grid by self
2.1. Idling characteristics E0 = f (If) of DC generator with separate excitation. synchronization.
2.2. Short-circuit characteristics IK = f (If) of DC generator with separate excitation. 5.3. Power angle characteristics P=f(), Q=f(), U=f().
2.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with separate 5.4. U-shape characteristic I=f(If).
6. Three-phase synchronous motor.
excitation.
6.1. Starting-up synchronous motor.
2.4. Characteristic U = f (I) of DC generator with shunt excitation 6.2. Power angle characteristics P=f(), Q=f(), U=f()..
3. DC motor with shunt excitation. 6.3. U-shape characteristic I=f(If).
3.1. Electromechanical (speed) characteristics n = f (I). Electric drives
3.2. Operational characteristics n = f (P2), P1 = f (P2), M = f (P2), = f (P2) of DC
motor with shunt excitation. 7. Electric drive using DC shunt motor.
4. Three-phase induction generator. 7.1. Speed control by changing resistance in armature circuit of DC motor.
4.1. Power characteristics =f(n), Q=f(n). 7.2. Speed control by changing armature voltage of DC motor supplied from
4.2. Ideal idling characteristics I0=f(U), Q0=f(U). EMF source.
4.3. Operational characteristics n=f(), I=f(), Q=f(), cos=f(P). 7.3. Speed control by changing armature voltage of DC motor supplied from
5. Three-phase squirrel-cage induction motor. thyristor converter.
8.6. Idling characteristics I0 = f (U), P0 = f (U), cos0 = f (U) . 7.4. Determining coordinates of electric drive with DC shunt motor in
5.2. Short-circuit characteristics IK = f (U), RK = f (U), cosK = f (U) .. generator, engine and braking modes.
5.3. Mechanical characteristic n = f (M). 8. Electric drive using three-phase induction motor.
8.1. Speed control of squirrel-cage induction motor by changing stator
5.4. Operational characteristics I = f (P2), P1 = f (P2), s = f (P2), = f (P2),
voltage.
cos = f (P2), M = f (P2).. 8.2. Speed control of squirrel-cage induction motor by match changing
9. Three-phase slip-ring induction motor. frequency and magnitude of stator voltage.
6.1. Mechanical characteristic n = f (M). 8.3. Speed control of slip-ring induction motor by changing rotor rheostat
6.2. Operational characteristics I = f (P2), P1 = f (P2), s = f (P2), = f (P2), resistance.
cos = f (P2), M = f (P2). 8.4. Determining coordinates of electric drive Induction squirrel-cage motor
10. Three-phase synchronous generator. electric source of industrial frequency in generator, engine and
10.1. Idle characteristic E0=f(If). braking modes.
10.2. Short-circuit characteristic I=f(If). 8.5. Determining coordinates of electric drive Induction squirrel-cage motor
10.3. External U=f(I), regulating If= f(I) and load U=f(If) characteristics. frequency converter in generator, engine and braking modes.

Page 261
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
10.4. Electric drive using synchronous motor. 12 Line Reactor 1
10.5. Regulating reactive power of three-phase synchronous motor by changing its 13 Synchronization Module 1
excitation. 14 Rectifier 1
10.6. Determining coordinates of electric drive Three-phase synchronous motor electric 15 Rheostat 1
source of industrial frequency in generator, engine and braking modes. 16 Three-phase Transformer Group 1
11. Automated (Closed-loop controlled) electric drives.
17 Adjustable Three-phase Autotransformer 1
11.1. Thyristor converter DC separately excited motor with speed control.
11.2. Thyristor converter DC separately excited motor with speed subordinate control. 18 Controllers Module 1
11.3. Thyristor converter DC separately excited motor with subordinate control by 19 Voltage-and-frequency Meter 1
voltage. 20 Synchronous Machine Torque Angle Meter 1
11.4. Frequency converter induction squirrel-cage motor with speed control. 21 Speed Indicator 1
. 22 Power Meter 1
23 Multimeters Module (3 Multimeters) 1
Module / Component Pcs 24 Voltmeter 1
1 Electromechanical Unit (DC Machine 101.2, AC Machine 102.1 and 1 25 Ammeter 1
Angular Displacement Transducer) 26 Laboratory Table with 2-level Frame 2
2 Three-phase Power Supply 1 27 Laboratory Table with 2-section Storage Container and 2-level 1
3 DC Motor Power Supply 1 Frame
4 Thyristor Converter/Controller 1 28 Accessories Kit 1
5 Synchronous Machine Exciter 1 29 Basic Experiments Guide 1
6 Frequency onverter 1 30 Operation Manual 1
7 Single-phase Power Supply 1 31 USB Oscilloscope AKIP-4107 (5 MHz) or similar 1
8 Three-pole Breaker 2 32 Notebook 1
9 Terminal 1
10 Active Load 1
11 AC Machine Rotor Rheostat 1

Page 262
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
22 Electrical Engineering And Fundamentals 1 Set Unit Prices Total Prices
Of Electronics Labware Set Type / Model ( Rupiah ) ( Rupiah )
EOE3M-N-R Please Contact Us
Ordering Information
List of basic experiments:

Electrical and magnetic circuits


1. DC circuits.
1.1. Parameters of electrical DC circuit.
1.1.1. Series resistor connection.
1.1.2. Parallel resistor connection.
1.1.3. Series-parallel resistor connection.
1.2. Volt-ampere characteristics of nonlinear elements in DC circuit.
2. Single-phase AC circuits.
2.1. Series connection of elements R, L and (sinusoidal current).
2.2. Parallel capacitor-inductor connection.
3. Three-phase AC circuits.
3.1. Star connection of three-phase electrical load.
3.2. Delta connection of three-phase electrical load.
3.3. Failure modes of three-phase circuit with load connected star.
3.4. Failure modes of three-phase circuit with load connected delta.
4. Magnetic circuits.
4.1. DC magnetic circuits.
4.2. AC magnetic circuits.
4.3. Test of single-phase transformer.

Fundamentals of electronics
1. Single-phase rectifier.
2. Three-phase bridge-circuit controlled rectifier.
3. Controlled rectifiers and thyristor regulator.
4. Two-stage transistor amplifier.
5. DC voltage stabilizer.

Page 263
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1. RS-trigger, multivibrator and single-shot trigger. Name Pcs
2. Circuits with operational amplifiers. 1 Electromechanical set (DC machine, AC motor and angle-to-digit 1
converter)
Electrical machines and drives 2 Voltage generators & testing board 1
3 Frequency converter 1
1. DC generators with independent excitation. 4 Single-phase power supply 2
1.1. No-load characteristic E0=f(IF) .
5 Active load 1
1.2. Short circuit characteristic ISC=f(IF).
1.3. Characteristics U = f (I), IF = f (I) and U = f (IF). 6 DC machine excitation rheostat 1
7 Adjustable autotransformer 1
2. DC motors with shunt excitation and drive on its basis. 8 Rectifier 1
9 Speed indicator 1
2.1.Electromechanical (speed) characteristic n = f (I). 10 Three multimeters module 1
2.2.Mechanical characteristics n = f (M). 11 Two multimeters module 1
2.3.Speed control of DC motor by changing armature voltage. 12 Wattmeter 1
2.4.Speed control of DC motor by field current changing. 13 Voltammeter 1
2.5.Determination of coordinates of electrical motor in motor, generator, and braking
14 Set of minimodules Electrical and electronic components 1
modes.
3. Three-phase asynchronous motor with squirrel-cage rotor and drive on its basis. 15 Two-level frame with container 1
3.1. Electromechanical (speed) characteristic n = f (I). 16 Single-level frame with container (length 910 mm) 1
3.2. Mechanical characteristic n = f (M). 17 Set of accessories 1
3.3. Speed control by match changing frequency and magnitude of stator voltage . 18 Set of accessories 1
3.4. Determination of coordinates of electrical drive in motor, generator, and braking 19 User Manual Electrical circuits and fundamentals of electronics 1
modes. 20 User Manual Electrical machines and drive 1
21 Single-channel oscilloscope 1

Page 264
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Power consumption, VA, not more than 200
Electrical supply:
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Class of protection against electrical shock I
Overall dimensions, mm, not more than
- length 2x910
- width 300
- height 800
Weight, Kg, not more than 50

Page 265
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
23 Electrical Drives Labware Set 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
EP1M-N-R Please Contact Us
Ordering Information
List of basic experiments:

1. Mechanical matters of electric drive.


1.1. Finding electrical drive inertia moment by free run-out method.
1.2. Finding mechanical characteristic of working mechanism.
2. Electrical drive using DC motor with separate (shunt, series) excitation.
2.1 Finding electromechanical and mechanical characteristics of electrical drive in
motor, generator, and braking modes.
2.2. Speed control by changing resistance in armature circuit of DC motor.
2.3. Speed control by changing excitation current of DC motor.
2.4. Speed control by shunting field winding of DC series-wound motor.
2.5. Speed control by changing DC motor armature voltage.
2.6. Finding energy parameters of electrical drive with DC motor.
2.7. Measuring body temperature of DC motor.
3. Electrical drive using squirrel cage induction motor.
3.1. Finding electromechanical and mechanical characteristics of electrical drive with
induction motor in motor, generator, and braking modes.
3.2. Speed control by match changing frequency and magnitude of stator voltage.
3.3. Finding energy parameters of electrical drive with induction motor .
3.4. Measurement body temperature of induction motor.

Page 266
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Name Pcs Power consumption, VA, not more 500
1 Electromechanical set with flywheel (DC machine, AC machine and angle-to- 1 than
digit converter) Electrical supply:
-three-phase AC circuit with
2 Three-phase power supply 1
working neutral and protective
3 Single-phase thyristor converter 1 leads 380 38
4 Frequency converter 1 - voltage, V
5 Single-phase power supply 1 - single-phase AC circuit with
6 Active load 1 working neutral and protective 220 22
7 DC machine excitation rheostat 1 leads 50 0,5
8 Adjustable autotransformer 1 - voltage, V
- frequency, Hertz
9 Rectifier 1
Class of protection against electrical I
10 Rheostat 1 shock
11 Three-phase transformer group 1 Overall dimensions, mm, not more
12 Speed indicator 1 than 2x910
13 Two multimeters module 1 - length 300
14 Voltammeter 1 - width 800
15 Multifunctional electrical measuring instrument 1 - height
Weight, Kg, not more than 100
16 Two-level frame with container 2
17 Set of accessories 1
18 User Manual Electric drive 1
19 Stop watch 1

Page 267
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
24 Executive DC motor 1 Set Unit Prices Total Prices
Power consumption, VA 50 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
- single-phase AC circuit with IDPT1-N-R Please Contact Us
working neutral and protective leads P I C T U R E
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 625
- width 500
- height 400
Weight, Kg 10

Module / Component Pcs


1 Single-phase Power Supply 1
2 Multimeters Module (2 Multimeters) 1
3 Single-level Desktop Frame with Container (length 625 mm) 1
4 Accessories Kit 1
. 5 Basic Experiments Guide 1
6 Operation Manual 1
7 Didactic Materials CD 1
BASIC EXPERIMENTS

1.1. Executive DC armature-controlled motor. Mechanical characteristic.


1.2. Regulating characteristic. Mechanical power characteristic.
2. Executive DC pulse-controlled motor.
2.1. Mechanical characteristic. ; Regulating characteristic. ; Mechanical power
characteristic

Page 268
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
25 Executive stepper motor 1 Set Unit Prices Total Prices
Power consumption, VA 50 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
- single-phase AC circuit with ISHD1-N-R Please Contact Us
working neutral and protective leads P I C T U R E
voltage, V 220 22
- frequency, Hz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 625
- width 500
- height 400
Weight, Kg 10

Module / Component Pcs


1 Single-phase Power Supply 1
2 Executive Stepper Motor Module 1
3 Single-level Desktop Frame with Container (length 625 mm) 1
4 Accessories Kit 1-- 1
5 Basic Experiments Guide 1
6 Operation Manual 1
7 Didactic Materials CD 1
BASIC EXPERIMENTS

1.1. Stepper motor phases commutation method.


1.2. Evaluating stepper motor positioning preciseness.
1.3. Stepper motor windings currents action on its characteristics.

Page 269
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
26 Wind Power Generator Full-Scale Model Labware Set 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA, not more than 100 NEE2VEG-N-R Please Contact Us
Electrical supply:
- single-phase AC circuit with P I C T U R E
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Class of protection against electrical shock I
Overall dimensions, mm, not more than
- length 910
- width 500
- height 400
Weight, Kg, not more than 10
Name Pcs
1 Load & Measurement module 1
2 Tachometer stand 1
3 Set of accessories 1
4 User Manual WIND POWER GENERATOR FULL-SCALE MODEL 1
5 Tachometer 1
6 Wind-turbine generator 1
7 Fan 1
8 Anemometer 1

Page 270
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
List of basic experiments:

4. Synchronous generator with permanent magnet.


4.1. Finding no-load characteristic E=f(n).
4.2. Finding external characteristics U=f(I), =f(I).
4.3. Finding speed characteristics U=f(n), I=f(n) =f(n) at constant load resistance.
5. Wind-electrical synchronous generator.
5.1. Finding dependences of generator power and wind turbine rotational moment from speed =f(n) and =f(n) at constant wind speed.
5.2. Finding dependence of turbine speed from wind speed n=f(v) at constant generator load.
5.3. Finding dependence of generator power from wind speed =f(v) at constant turbine speed.
5.4. Finding dependence of turbine speed from wind speed n=f(v) at max value of generator power.
5.5. Finding dependence of max value of generator power from blade s number of wind turbine =f(m).

Page 271
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
27 Model Of Pv Solar Power Plant Labware Set 1 Set Unit Prices Total Prices
Power consumption, VA, not more than 700 Type / Model ( Rupiah ) ( Rupiah )
Electrical supply:
- single-phase AC circuit with NEE3-MFESE-N-R Please Contact Us
working neutral and protective leads P I C T U R E
- voltage, V 220 22
- frequency, Hertz 50 0,5
Class of protection against electrical shock I
Overall dimensions, mm, not more than
- length 910
- width 850
- height 1600
Weight, Kg, not more than 80

List of basic experiments:

5.6. Characteristics of photovoltaic module.


1.1. Finding volt-ampere characteristic U=f(I).
1.2. Finding energy characteristics P=f(U).
1.3. Finding dependence of short circuit current from irradiance ISC=f().
1.4. Finding dependence of short circuit current from angle of light rays inclination toward
surface of photovoltaic module ISC=f()
1.5. Finding dependence of short circuit current from the temperature of photovoltaic
module ISC =f().
1.6. Finding dependence of open-circuit voltage from the temperature of photovoltaic
module UOC =f().
1.7. Finding dependence of maximum power from the temperature of photovoltaic module
M=f()..
2.Model of autonomous PV solar power plant.
2.1. Finding operating characteristics of rechargeable battery controller.
Simulation of modes of autonomous PV solar power plant

Page 272
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Name Pcs
1 Power supply module 1
2 Charge-discharge controller 1
3 Photovoltaic module 1
4 Load & Measurement module 1
5 Light source 1
6 Two multimeters module 1
7 Two-level frame with container 1
8 Set of accessories 1
9 Manual Alternative power generation - PV solar power plant model 1
10 Operating instructions 1
11 CD with didactic materials 1

Page 273
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
28 Fundamentals of electromechanics 1 Set Unit Prices Total Prices
Power consumption, VA 200 Type / Model ( Rupiah ) ( Rupiah )
Electric supply:
OEM1M-S-R Please Contact Us
- single-phase AC circuit with P I C T U R E
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Appliance class I
Total dimensions, mm (assembled)
- length 910
- width 850
- height 1600
Weight, Kg 75

1. DC generator with separate excitation.


1.1. Idling characteristic E0 = f (If) of DC generator with separate excitation.
1.2. Short-circuit characteristic IK = f (If) of DC generator with separate
excitation.
1.3. Characteristics U = f (I), If = f (I) and U = f (If) of DC generator with
separate excitation.
2. DC motor with shunt excitation.
2.1. Electromechanical (speed) characteristics n = f (I) of DC motor with
shunt excitation. ; 2.2. Mechanical characteristics of n = f (M) of DC motor with
shunt excitation.
2.3. Speed control of DC motor with shunt excitation by armature voltage
changing. ; 2.4. Speed control of DC motor with shunt excitation by field
current change..
3. Three-phase squirrel-cage induction motor.
3.1. Electromechanical (speed) characteristic n = f (I).
3.2. Mechanical characteristic n = f (M).
3.3. Speed control of three-phase squirrel-cage induction motor by match
stator voltage and frequency changing

Page 274
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Name Pcs
1 Electromechanical unit (DC machine 101.1 , AC motor 106 and angular 1
displacement transducer)
2 Frequency converter 1
3 Single-phase power supply 1
4 Active load 1
5 Excitation rheostat of DC machine 1
6 Adjustable autotransformer 1
7 Rectifier 1
8 Speed indicator 1
9 Module of 3 multimeters 1
10 Voltammeter 1
11 Laboratory table with container and 2-level frame 1
12 Set of accessories 1
13 Basic Experiments Guide Fundamentals of electromechanics 1
14 Operation manual 1
15 Didactic materials CD 1

Page 275
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
29 Neutral modes & Protective grounding in electric installations 1 Set Unit Prices Total Prices
2.1. Power consumption, VA 500 Type / Model ( Rupiah ) ( Rupiah )
2.2. Electric supply:
- three-phase AC circuit with RNZU1M-S-R Please Contact Us
working neutral and protective leads P I C T U R E
voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
voltage, V 220 22
- frequency, Hz 50 0,5
2.3. Appliance class I
2.4. Total dimensions, mm (assembled)
- length 2910
- width 850
- height 1600
2.5. Weight, Kg 180

2. Neutral modes in electric installations.


a. Modeling neutral modes in electric installation by changing transformer neutral
reactor reactance; finding dependences of sustained single-phase fault current,
unfaulty phase and neutral voltages from reactor reactance.
b. Modeling neutral modes in electric installation by changing transformer neutral
resistance; finding dependences of sustained single-phase fault current, unfaulty
phase and neutral voltages from the resistance.
c. Defining influence of removing transformer neutral on mode of effective neutral
grounding in electric installation.
d. Finding dependences of sustained single-phase fault current, phases voltages from
fault resistance in mode of electric installation isolated neutral.
e. Finding dependences of phase voltages, grounding transformer neutral voltage and
sustained single-phase fault current from fault resistance in mode of electric
installation compensated neutral.

Page 276
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
c. Finding dependences of phase voltages, grounding transformer neutral voltage and Module / Component Pcs
sustained single-phase fault current from fault resistance in network with resistive 1 Three-phase Power Supply 1
neutral grounding. 2 Single-phase Power Supply 1
19. Grounding arrangements of electric installations. 3 Active Load 1
a. Finding dependence of electric installation base potential from distance to ground 4 Model of ground fault 1
(for 5 soil types). 5 Transmission Line Model 2
b. Finding dependence of contact voltage from distance to ground (for 5 soil types). 6 Line Reactor 1
c. Finding dependence of step voltage from distance to ground (for 5 soil types). 7 Rheostat 1
8 Inductive Load 1
9 Model of grounding with vertical tubular electrode 1
10 Three-phase Transformer Group 1
11 Three-phase Transformer Group 1
12 Multimeters Module (3 Multimeters) 1
13 Laboratory Table with 2-level Frame 1
14 Laboratory Table with 2-section Storage Container and 2-level 1
Frame
15 Accessories Kit 1
16 Basic Experiments Guide 1
17 Operation Manual 1
18 Didactic Materials CD 1

Page 277
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
30 Relay Protection And Automation In Electricity Supply Systems 1 Set Unit Prices Total Prices
(Based On Electromagnetic Relays) Labware Set Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA, not more than 50 RZASESR1-N-R Please Contact Us
Electrical supply:
- single-phase AC circuit with P I C T U R E
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Class of protection against electrical shock I
Overall dimensions, mm, not more than
- length 910
- width 350
- height 800
Weight, Kg, not more than 20

List of basic experiments:


1. Relay protection.
1.1. Transmission line high-set overcurrent protection.
1.2. Transmission line instant current cutoff.
1.3. High-set overcurrent protection of radial electrical network with single supply.
1.4. Transmission line differential protection.
1.5. Transformer differential protection. .
1.6. Transmission line circuit breaker high-set overcurrent protection.
1.7. Thermal electrical relay thermal protection of electrical network .
2. Automation.
2.1. Automatic activation of backup of electrical load supply.
Transmission line autoreclosing

Page 278
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Name Pcs
1 Single-phase power supply 1
2 Electrical transmission line model 2
3 Push-button control station 1
4 Light signaling module 1
5 Electrothermal relay 1
6 Automatic single-pole switch 1
7 Contactor 2
8 Overcurrent relay 2
9 Undervoltage relay 1
10 Time relay 1
11 Interposing relay 2
12 Single-phase transformer 1
13 Current transformer 2
14 Current & time meter 1
15 Two-level frame with container 1
16 Set of accessories 1
17 User Manual Relay protection and automation in electricity supply systems 1
(based on electromagnetic relays)

Page 279
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
31 Electricity supply systems 1 Set Unit Prices Total Prices
2.1. Power consumption, VA 50 Type / Model ( Rupiah ) ( Rupiah )
2.2. Electric supply:
- single-phase AC circuit with SES2M-S-K Please Contact Us
working neutral and protective leads P I C T U R E
voltage, V 220 22
- frequency, Hz 50 0,5
2.3. Appliance class I
2.4. Total dimensions, mm (assembled)
- length 3910
- width 850
- height 1600
2.5. Weight, Kg 150

BASIC EXPERIMENTS

3. Electroreceiver modes.
3.1. Static power - voltage characteristic of resistive load.
3.2. Static power - voltage characteristic of inductive load (reactor).
3.3. Static power - voltage characteristic of capacitor bank..
3.4. Static power - voltage characteristic of rectifier load..
4. Distribution electric network modes.
4.1. Modeling steady state of single-phase transformer.
4.2. Modeling steady state of transmission line phase.
4.3. Modeling steady state of open distribution electric network phase.
5. Monitoring quality of electrical energy in power supply systems.
5.1. Measuring parameters of electric energy quality.
5.2. Viewing and registering measured quality parameters of electrical energy using
personal computer.
6. Control of electric energy quality in power supply systems.
6.1. Counter voltage regulation.
6.2. Voltage regulation by shunt reactive power compensation using capacitor package.
6.3. Voltage regulation by series reactive power compensation using capacitor package.
.

Page 280
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
1.1. Reducing current higher harmonics generation by replacing half-wave rectifier to full-wave rectifier in DC load power supply.
1.2. Compensation of current higher harmonics using compensating filter.
2. Relay protection.
5.1.Modeling transmission line overcurrent protection.
5.2.Modeling transmission line instantaneous current cutoff.
5.3.Modeling radial single-fed network overcurrent protection.
5.4.Modeling transmission line differential protection.
5.5.Modeling transformer differential protection
5.6.Modeling electric network overcurrent protection with automatic switch.
5.7.Modeling electric network thermal protection with thermal electric relay.
3. Automation.
3.1. Automatic switching transmission line supply back-up.
3.2. Automatic reclosing transmission line.
4. Electric safety.
4.1. Finding current through human body when its in direct touch to parts under voltage.
4.2. Finding current through human body when its in indirect touch to parts under voltage.
4.3. Action of protective neutral grounding.
4.4. The protective effect of automatic supply switching-off when overcurrent.
4.5. Action of RCCB. .
4.6. Action of protective grounding.
4.7. Phases insulation monitoring in network with isolated neutral.
Human being protection against electric shock in electric installations with grounding systems TN-C, TN-S, TN-C-S, TT, TI and IT.

Page 281
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Module / Component Pcs 24 Electric Supply Grid Model 1
1 Single-phase Power Supply 1 25 Model of electro receiver with working insulation 1
2 Electric Circuit Segment Model 1 26 Grounding Model 1
3 Active Load 2 27 Compensating Filter 1
4 Human Body Model 1 28 Current Transformer 2
5 Transmission Line Model 2 29 Multimeters Module (2 Multimeters) 1
6 Series Capacitive Compensating Device 1 30 Current and Time Measurer 1
7 Capacitive Load 1 31 Electricity Quality Indicators Meter 1
8 Adjustable Autotransformer 1 32 Single-phase Network Parameters Meter 1
9 Residual Current Device 1 33 Laboratory Table with 2-level Frame 2
10 Rectifier 1 34 Laboratory Table with 2-section Storage Container and 2-level 1
11 Inductive Load 2 Frame
12 Power Meter Commutator 1 35 Accessories Kit 1
13 Pushbutton Control Module 1 36 Basic Experiments Guide 1
14 Light Signaling Module 1 37 Basic Experiments Guide 1
15 Thermal Electrical Relay 1 38 Basic Experiments Guide 1
16 Automatic Single-pole Breaker 1 39 Operation Manual 1
17 Automatic Single-pole Breaker 1 40 Electricity Quality Indicators Meter Operation Manual LPW-305 1
18 Contactor 2 41 Electricity Quality Indicators Meter Operation Manual CD"LPW- 1
19 Overcurrent Relay 2 305"
20 Undervoltage Relay 1 42 Notebook 1
21 Time Relay 1
22 Auxiliary Relay 2
23 Single-phase Transformer 1

Page 282
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
32 Wiring technology 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
TEMR1-PMP-S Please Contact Us
BASIC EXPERIMENTS
1. Wiring and adjusting control circuits of three-phase
squirrelcage induction motort..
1.1. Wiring and adjusting irreversibly control circuit of three-
phase induction motor with manual push-button starter.
1.2. Wiring and adjusting irreversibly control circuit of three-
phase induction motor with contactor and electrothermal
relay. Wiring and adjusting reversibly control circuit of
three-phase induction motor with contactors and
electrothermal relays..
2. Wiring and adjusting electric circuits of residential and
office premises.
2.1. Wiring and adjusting apartment switchboard circuits with
two-wire electric network. Wiring and adjusting apartment
switchboard circuits with grounding system TN-C-S.
2.2. Wiring and adjusting office switchboard circuits with
grounding system TN-C-S. Wiring and adjusting apartment
group two-wire lighting and sockets electric circuits.
2.3. Wiring and adjusting apartment group lighting and sockets
electric circuits with grounding system TN-C-S.
2.4. Wiring and adjusting office group lighting and sockets
electric circuits with grounding system TN-C-S.
2.5. Wiring and adjusting electric circuit of lighting with motion
sensor. Wiring and adjusting electric circuit of lighting with
photo relay. Wiring and adjusting electric circuit of lighting
with timer. Wiring and adjusting apartment group lighting
with timer and sockets electric circuits with grounding
system TN-C-S.

Page 283
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Power consumption, VA 500 Module / Component Pcs
Electric supply: 1 Induction Motor 1
- three-phase AC circuit with 2 Three-phase Power Supply 1
working neutral and protective leads
3 Single-phase Power Supply 1
voltage, V 380 38
- frequency, Hz 50 0,5 4 Single-phase Sockets Module 1
Appliance class I 5 Mounting Panel 1
Total dimensions, mm (assembled) 6 Laboratory Table with 2-section Storage Container and 2-level 1
- length 910 Frame
- width 850 7 Accessories Kit 1
- height 1700 8 Basic Experiments Guide 1
Weight, Kg 50
9 Basic Experiments Guide 1
10 Operation Manual 1
11 Didactic Materials CD 1
12 Multimeter 1
13 Components Set for Electric Wiring of Control Schemes for Three 1
phase Induction Motor with Squirrel Cage Rotor
14 Components Set for Electric Wiring in Residential and Office 1
Premises

Page 284
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT BRAND
No Name of Equipment Quantity G A L S E N
33 Three-phase Synchronous Generator 1 Set Unit Prices Total Prices
Type / Model ( Rupiah ) ( Rupiah )
Power consumption, VA, not more than 500 TSG1-N-R Please Contact Us
Electrical supply:
-three-phase AC circuit with P I C T U R E
working neutral and protective leads
- voltage, V 380 38
- single-phase AC circuit with
working neutral and protective leads
- voltage, V 220 22
- frequency, Hertz 50 0,5
Class of protection against electrical shock I
Overall dimensions, mm, not more than
- length 3x910
- width 350
- height 800
Weight, Kg, not more than 150
List of basic experiments:

1. Connection in parallel power network.


1.1. Ideal synchronizing.
1.2. Coarse synchronizing.
2. Characteristics.
2.1. Finding no-load characteristic E0=f(If) .
2.2. Finding short-circuit characteristic ISC=f(If).
2.3. Finding output U=f(I), regulation If= f(I) and load U=f(If) characteristics.
2.4. Finding angle characteristics P=f(), Q=f(), U=f().
2.5. Finding U-curve characteristic I=f(If).

Page 285
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com
EQUIPMENT
Name Pcs
1 Electromechanical set (DC machine, AC machine and angular displacement 1
transducer)
2 Three-phase power supply 1
3 DC machine power supply 1
4 Synchronous machine exciter 1
5 Single-phase power supply 1
6 Three-pole switch 1
7 Active load 1
8 Line reactor 1
9 Capacitive load 1
10 Sychronizing module 1
11 Inductive load 1
12 Three-phase transformer group 1
13 Voltage & frequency meter 1
14 Synchronous machine torque angle indicator 1
15 Speed indicator 1
16 Wattmeter 1
17 Three multimeters module 1
18 Two-level frame with container 2
19 Set of accessories 1
20 Manual Three-phase synchronous generator 1
21 Operating instructions 1

Page 286
INDONESIA Authorized Agent Please Contact:
PT. ADHIKARSA KARYA SAINTIKA
Jl. P. Saparua Raya No. 218, Bekasi 17111, I N DO N E S I A
Telp. No. : (+62-21) 8888 3420, Fax No. : (+62-21) 8887 8945, E-mail : sales@ptakasa.com, Web-site : http://www.ptakasa.com

S-ar putea să vă placă și