Fusing Products
Expulsion Fuses Oil-Immersed, Current-Sensing Weak-Link Cartridge Fuse 240-31 26
Oil-Immersed, Dual-Sensing Weak-Link Cartridge Fuse 240-32 26
Interrupter MagneX Interrupter Two- and Three-Phase 240-33 27
MagneX Interrupter Single-Phase 240-34 28
Bay-O-Net Holder/Fuses Sidewall-Mounted Flapper Bay-O-Net Assembly 240-40 29
Sidewall-Mounted Flapper Bay-O-Net Assembly w/Silver Plating 240-40 29
Cover-Mounted Bay-O-Net Assembly 240-40 29
Bay-O-Net Fuse Assembly Drip Guard 240-41 29
Current-Sensing Bay-O-Net Fuse Link 240-45 29
Dual-Sensing Bay-O-Net Fuse Link 240-46 30
Isolation Link 240-47 30
Dual Element Bay-O-Net Fuse Link 240-48 31
High Ampere Overload Bay-O-Net Link 240-49 31
Under-Oil Backup Current-Limiting Fuse ELSP Current-Limiting Backup Fuse 240-50 32
Clip-Mounted Current-Limiting Fuses ELX Full-Range Current-Limiting Fuse 240-55 33
X-Limiter Full-Range Current-Limiting Fuse 240-56 34
Current-Limiting Fuse Mounts 240-59 37
NX Indoor Full-Range Current-Limiting Fuse 240-60 39
Current-Limiting Fuses NXC Current-Limiting Capacitor Fuse 240-61 44
Direct-Connected Capacitor Fuse 240-63 44
EL Bay-O-Net Assembly 240-70 46
ELS Full-Range Current-Limiting Fuse 240-72 47
15 and 25 kV Class Fused Loadbreak Elbow Current-Limiting Fuse 240-97 48
Power Fuses ELSG Full-Range Current-Limiting Fuse 240-82 49
X-Limiter Hinge-Mounted Current-Limiting Fuse 240-84 51
Edison Modular Fuse 240-92 54
CMU Power Fuse 240-94 55
Separable Connectors
Loadbreak Connectors Loadbreak Elbows 200 A, 15 kV, 25 kV, 28 kV & 35 kV 500-10-7, 81
10-7C, 28-7,
28-7C, 41
POSI-Break Loadbreak Elbow, Protective Cap 200 A, 25 kV, 500-29-7, 83
28 kV 29-7C, 37, 37C
Loadbreak Bushing Insert 200 A, 15 kV, 25 kV & 28 kV 500-12, 26, 26C 83
Rotatable Feedthru Insert 200 A, 15 kV, 25 kV & 28 kV 500-13, 30, 30C 84
Loadbreak Portable Feedthru 200 A, 15 kV, 25 kV, 28 kV 500-14, 31, 31C, 84
& 35 kV 49
Loadbreak Junction 200 A 15 kV, 25 kV, 28 kV & 35 kV 500-15, 32, 32C, 85
51
Insulated Bushing Well Plug 200 A, 15/25 kV, 28 kV 500-20*, 38, 38C 86
Loadbreak Protective Cap 200 A, 15 kV, 25 kV, 28 kV 500-21, 39, 39C 86
Loadbreak Protective Cap 200 A, 35 kV 500-65 87
Insulated Standoff Bushing 200 A, 15 kV, 25 kV, 28 kV 500-22, 40, 40C, 87
& 35 kV 66
Fused Loadbreak Elbow Connector 200 A, 15 and 25 kV 500-110, 111 87
* See 500-38
B100-95023 3
Catalog Page
Product Type Product Section Number
Deadbreak Connector, 200 A Elbow Connector 550-10 88
Straight Connector 550-12 88
Deadbreak Connectors BOL-T Connector 600 A, 15/25 kV, 35 kV 600-30, 50 88
BT-TAP Connector Kit 600 A, 15 kV, 25 kV & 35 kV 600-15, 35, 55 89
T-OP II Connector 600 A, 15, kV, 25 kV, & 35 kV 600-12, 32, 52 95
PUSH-OP Connector 600 A, 15 kV, 25 kV, 35 kV 600-13, 33, 53 96
U-OP Connector 600 A, 15 kV & 25 kV 600-34 97
Bushing Adapter with LRTP 600 A, 15 kV, 25 kV & 35 kV 600-18, 38, 59 97
PUSH-OP Bushing Adapter 600 A, 15 kV, 25 kV & 35 kV 600-19, 39, 58 98
Protective Cap (Standard, T-OP II and U-OP) 600 A 15/25 kV, 35 kV 600-43, 63 99
Standoff Bushings 600 A 15/25 kV, 28 kV 600-44, 44C, 64 100
Deadbreak Junctions 600 A 15/25 kV, & 28 kV & 35 kV 600-42, 42C, 62 101
Loadbreak/Deadbreak Connectors
Loadbreak/Deadbreak Connectors 200 A and 600 A, 15, 25 and 35 kV Junction Bars for Separable 650-10 103
Connectors
Fault Indicators
Fault Indicators Test Point Reset 320-40 115
Pathfinder Test Point Reset 320-42 115
Mounting Bracket
ASZ4C1 2 / POLE
RATED 480V
MCOV 400V
1.
1 Pole, 240 V (240 V MCOV) without ASZH240C100
Mounting Bracket
2 Pole, 240 V (240 V MCOV) without ASZH240C200
Mounting Bracket
3 Pole, 240 V (240 V MCOV) without ASZH240C300
Mounting Bracket
1 Pole, 480 V (400 MCOV) without ASZH480C100
Mounting Bracket
2 Pole, 480 V (400 MCOV) without ASZH480C200
Mounting Bracket
3 Pole, 480 V (480 V MCOV) without ASZH480C300
Mounting Bracket
1 Pole, 650 V (540 MCOV) without ASZH650C100
Mounting Bracket
2 Pole, 650 V (540 MCOV) without ASZH650C200
Mounting Bracket
3 Pole, 650 V (540 V MCOV) without ASZH650C300
Mounting Bracket
VariSTAR Storm Trapper H.E. 235-16 Internally mounted High Light Duty Distribution Class 2 Pole, 480 V (400 V MCOV), 0.391 ASZH480U200
S235-16-1 Energy secondary surge Surge Arrester for transformer inch Mounting Hole, 10 inch Leads
arresters for overvoltage secondary overvoltage with Terminal
protection of transformer protection, internal (under-oil)
secondary bushings. mount. 2 Pole, 480 V (400 V MCOV), 0.531 ASZH480U201
inch Mounting Hole, 24 inch Leads w/o
Terminal
2 Pole, 480 V (400 V MCOV), 0.391 ASZH480U202
inch Mounting Hole, 24 inch Leads w/o
Terminal
2 Pole, 480 V (400 V MCOV), 0.766 ASZH480U203
inch Mounting Hole, 24 inch Leads w/o
Terminal
B100-95023 5
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
ARRESTER/OPEN LINK CUTOUT COMBINATIONS
Arrester/Open Link Cutout 235-25 Surge Arrester/Open Link Combination Arrester/Open 9 kV (7.65 kV MCOV), 50A Continuous, URT09050K1C1D1A
Combination, Evolution URT Type, S235-25-1 cutout mounted externally to Link Fuse Cutout combination 1200 A Interrupting Arrester/Flipper
UltraSIL Polymer-Housed S235-25-2 the transformer tank. Used for primary winding Fuse Combination
for overvoltage/overcurrent overvoltage/overcurrent
protection of the transformer. protection. Heavy-duty, 10 kV (8.40 kV MCOV), 50 A URT10050K1C1D1A
polymer-housed, MOV arrester Continuous, 1200 A Interrupting
with non-decaying (infinite) Arrester/Flipper Fuse Combination
TOV, transformer mounting 18 kV (15.3 kV MCOV), 50 A URT18080K1C1D1A
bracket, isolator, and ground Continuous, 1200 A Interrupting
strap. Arrester/Flipper Fuse Combination
Arrester/Open Link Cutout 235-25 Surge Arrester/Open Link Combination Arrester/Open 9 kV (7.65 kV MCOV), 50 A UNS09050K1C1D1A
Combination, Normal-Duty S235-25-1 cutout mounted externally to Link Fuse Cutout combination Continuous, 1200 A Interrupting
VariSTAR, UltraSIL Polymer- S235-25-2 the transformer tank. Used for primary winding Arrester/Flipper Fuse Combination
Housed for overvoltage/overcurrent overvoltage/overcurrent
protection of the transformer. protection. Normal duty, 10 kV (8.40 kV MCOV), 50 A UNS10050K1C1D1A
polymer-housed, non-gapped Continuous, 1200 A Interrupting
MOV arrester with transformer Arrester/Flipper Fuse Combination
mounting bracket, isolator, and 18 kV (15.3 kV MCOV), 50 A UNS18080K1C1D1A
ground strap. Continuous, 1200 A Interrupting
Arrester/Flipper Fuse Combination
Arrester/Open Link Cutout 235-25 Surge Arrester/Open Link Combination Arrester/Open 9 kV (7.65 kV MCOV), 50 A UHS09050K1C1D1A
Combination, Heavy-Duty S235-25-1 cutout mounted externally to Link Fuse Cutout combination Continuous, 1200 A Interrupting
VariSTAR, UltraSIL Polymer- S235-25-2 the transformer tank. Used for primary winding Arrester/Flipper Fuse Combination
Housed for overvoltage/overcurrent overvoltage/overcurrent
protection of the transformer. protection. Heavy-duty, 10 kV (8.40 kV MCOV), 50 A UHS10050K1C1D1A
polymer-housed, non-gapped Continuous, 1200 A Interrupting
MOV arrester with transformer Arrester/Flipper Fuse Combination
mounting bracket, isolator, and 18 kV (15.3 kV MCOV), 50 A UHS18080K1C1D1A
ground strap. Continuous, 1200 A Interrupting
Arrester/Flipper Fuse Combination
B100-95023 7
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
LIGHT-DUTY DISTRIBUTION-CLASS ARRESTERS - UNDER-OIL MOUNTING
Light-Duty Distribution-Class 235-95 Mounted under-oil inside the Light-Duty Distribution-Class 3 kV, (2.55 kV MCOV) CLU23A03
Arrester, VariSTAR Type CLU, S235-95-1 Transformer Tank, connected MOV arrester, for primary
Under-Oil Application. to the primary winding. winding overvoltage protection. 6 kV, (5.1 kV MCOV) CLU23A06
Under-oil application. With 9 kV, (7.65 kV MCOV) CLU23A09
Line Lead, Ground Lead, and
isolation link (ground side). 10 kV, (8.4 kV MCOV) CLU23A10
Arrester Block Assembly shall 12 kV, (10.2 kV MCOV) CLU23A12
be composite wrapped.
15 kV, (12.7 kV MCOV) CLU23A15
18 kV, (15.3 kV MCOV) CLU23A18
21 kV, (17.0 kV MCOV) CLU23A21
24 kV, (19.5 kV MCOV) CLU23A24
27 kV, (22.0 kV MCOV) CLU23A27
30 kV, (24.4 kV MCOV) CLU23A30
33 kV, (27 kV MCOV) CLU23A33
36 kV, (29 kV MCOV) CLU23A36
HEAVY-DUTY DISTRIBUTION-CLASS ARRESTERS - UNDER-OIL MOUNTING
Heavy-Duty Distribution-Class 235-64 Mounted under-oil inside the Heavy-Duty Distribution-Class 3 kV, (2.55 kV MCOV) AZU100L003
Arrester, VariSTAR Type AZU, S235-64-1 Transformer Tank, connected MOV arrester, for primary
Under-Oil Application. to the primary winding. winding overvoltage protection. 6 kV, (5.1 kV MCOV) AZU100L006
Under-oil application. With 9 kV, (7.65 kV MCOV) AZU100L009
Line Lead and Ground Lead.
10 kV, (8.4 kV MCOV) AZU100L010
12 kV, (10.2 kV MCOV) AZU100L012
15 kV, (12.7 kV MCOV) AZU100L015
18 kV, (15.3 kV MCOV) AZU100L018
21 kV, (17.0 kV MCOV) AZU100L021
24 kV, (19.5 kV MCOV) AZU100L024
27 kV, (22.0 kV MCOV) AZU100L027
30 kV, (24.4 kV MCOV) AZU100L030
M.O.V.E. DirectConnect Elbow 235-101 Overvoltage protection for Metal Oxide non-gapped 27 kV (22.0 kV MCOV) DCEA635M27
Arrester S235-100-1 deadfront pad-mounted Loadbreak Elbow Arresters
apparatus (35 kV, 600 A for overvoltage protection 30 kV (24.4 kV MCOV) DCEA635M30
bushings). of underground distribution
system equipment and cables.
B100-95023 11
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
intermediate-class surge arresters - polymer-housED
Intermediate-Class Surge 235-75 Overvoltage protection for Intermediate-Class, polymer- 3 kV, (2.55 kV MCOV), 8.75 - 10 Bolt Circle UI003A
Arrester, Type UI, UltraSIl S235-75-1 substation (or near substation) housed MOV arrester, for
Polymer-Housed equipment. overvoltage protection of 6 kV, (5.1 kV MCOV), 8.75 - 10 Bolt Circle UI006A
electrical equipment. 9 kV, (7.65 kV MCOV), 8.75 - 10 Bolt Circle UI009A
10 kV, (8.4 kV MCOV), 8.75 - 10 Bolt Circle UI010A
12 kV, (10.2 kV MCOV), 8.75 - 10 Bolt Circle UI012A
15 kV, (12.7 kV MCOV), 8.75 - 10 Bolt Circle UI015A
18 kV, (15.3 kV MCOV), 8.75 - 10 Bolt Circle UI018A
21 kV, (17.0 kV MCOV), 8.75 - 10 Bolt Circle UI021A
24 kV, (19.5 kV MCOV), 8.75 - 10 Bolt Circle UI024A
27 kV, (22.0 kV MCOV), 8.75 - 10 Bolt Circle UI027A
30 kV, (24.4 kV MCOV), 8.75 - 10 Bolt Circle UI030A
33 kV, (27.5 kV MCOV), 8.75 - 10 Bolt Circle UI033A
36 kV, (29.0 kV MCOV), 8.75 - 10 Bolt Circle UI036A
39 kV, (31.5 kV MCOV), 8.75 - 10 Bolt Circle UI039A
42 kV, (34.0 kV MCOV), 8.75 - 10 Bolt Circle UI042A
45 kV, (36.5 kV MCOV), 8.75 - 10 Bolt Circle UI045A
48 kV, (39.0 kV MCOV), 8.75 - 10 Bolt Circle UI048A
54 kV, (42.0 kV MCOV), 8.75 - 10 Bolt Circle UI054A
60 kV, (48.0 kV MCOV), 8.75 - 10 Bolt Circle UI060A
66 kV, (53.0 kV MCOV), 8.75 - 10 Bolt Circle UI066A
72 kV, (57.0 kV MCOV), 8.75 - 10 Bolt Circle UI072A
78 kV, (62.0 kV MCOV), 8.75 - 10 Bolt Circle UI078A
84 kV, (68.0 kV MCOV), 8.75 - 10 Bolt Circle UI084A
90 kV, (70.0 kV MCOV), 8.75 - 10 Bolt Circle UI090A
96 kV, (76.0 kV MCOV), 8.75 - 10 Bolt Circle UI096A
108 kV, (84.0 kV MCOV), 8.75 - 10 Bolt Circle UI108A
B100-95023 13
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
Porcelain Top Station-Class 235-87 180 kV (144 kV MCOV) AZES022G144180
Arrester, VariSTAR, Type AZES, S235-87-1 192 kV (152 kV MCOV) AZES022G152192
Porcelain Housing (Metal Top)
(continued) 198 kV (160 kV MCOV) AZES023G160198
204 kV (165 kV MCOV) AZES024G165204
216 kV (174 kV MCOV) AZES024G174216
228 kV (182 kV MCOV) AZES025G182228
240 kV (190 kV MCOV) AZES025G190240
258 kV (209 kV MCOV), Triple Unit, with AZES067G209258
Two Grading Rings, 10 Bolt circle, with
NEMA Connectors
264 kV (212 kV MCOV) AZES067G212264
276 kV (220 kV MCOV) AZES069G220276
288 kV (230 kV MCOV) AZES069G230288
294 kV (235 kV MCOV), Triple Unit with AZES070G235294
Three Grading Rings,10 Bolt circle, with
NEMA Connectors
300 kV (239 kV MCOV) AZES070G239300
312 kV (245 kV MCOV) AZES071G245312
330 kV (267 kV MCOV) AZES074G267330
336 kV (269 kV MCOV) AZES074G269336
360 kV (289 kV MCOV) AZES075G289360
Metal Top Station-Class Arrester, 235-87 Overvoltage protection for Metal Oxide Station Class, 3 kV (2.55 kV MCOV), Single Unit, 10 Bolt AZES091G002003
VariSTAR, Type AZES, Porcelain S235-87-1 substation equipment. porcelain-housed surge Circle, with NEMA Connectors
Housing (Cubicle-Mounted) arresters for overvoltage 6 kV (5.1 kV MCOV) AZES091G005006
protection of substation
electrical equipment. Cubical- 9 kV (7.65 kV MCOV) AZES091G007009
mounted design for confined 10 kV (8.4 kV MCOV) AZES092G008010
space application.
12 kV (10.2 kV MCOV) AZES092G010012
15 kV (12.7 kV MCOV) AZES092G012015
18 kV (15.3 kV MCOV) AZES093G015018
21 kV (17.0 kV MCOV) AZES093G017021
24 kV (19.5 kV MCOV) AZES093G019024
27 kV (22.0 kV MCOV) AZES094G022027
30 kV (24.4 kV MCOV) AZES094G024030
33 kV (27.5 kV MCOV) AZES094G027033
36 kV (29.0 kV MCOV) AZES094G029036
39 kV (31.5 kV MCOV) AZES095G031039
42 kV (34.0 kV MCOV) AZES095G034042
45 kV (36.5 kV MCOV) AZES095G036045
48 kV (39.0 kV MCOV) AZES095G039048
B100-95023 15
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
Station-Class Surge Arrester, 235-88 168 kV, (131.0 kV MCOV) US168A
Type US, UltraSIL Polymer- S235-88-1
Housed 172 kV, (140.0 kV MCOV) US172A
(continued) 180 kV, (144.0 kV MCOV) US180A
192 kV, (192.0 kV MCOV) US192A
198 kV, (160.0 kV MCOV) US198A
204 kV, (165.0 kV MCOV) US204A
216 kV, (174.0 kV MCOV) US216A
228 kV, (180.0 kV MCOV) US228A
240 kV, (190.0 kV MCOV) US240A
Station-Class Surge Arrester, 235-88 Overvoltage protection for Station Class, polymer-housed 3 kV, (2.55 kV MCOV) UH003A
Type UH, UltraSIL Polymer- S235-88-1 substation equipment. MOV arrester, for overvoltage
Housed protection of electrical 6 kV, (5.1 kV MCOV) UH006A
H = High Energy Handling equipment. 9 kV, (7.65 kV MCOV) UH009A
5.6 kJ/kV of MCOV (3-108 kV)
8.9 kJ/kV of MCOV (120-240 kV) 10 kV, (8.4 kV MCOV) UH010A
12 kV, (10.2 kV MCOV) UH012A
15 kV, (12.7 kV MCOV) UH015A
18 kV, (15.3 kV MCOV) UH018A
21 kV, (17.0 kV MCOV) UH021A
24 kV, (19.5 kV MCOV) UH024A
27 kV, (22.0 kV MCOV) UH027A
30 kV, (24.4 kV MCOV) UH030A
33 kV, (27.5 kV MCOV) UH033A
36 kV, (29.0 kV MCOV) UH036A
39 kV, (31.5 kV MCOV) UH039A
42 kV, (34.0 kV MCOV) UH042A
45 kV, (36.5 kV MCOV) UH045A
48 kV, (39.0 kV MCOV) UH048A
54 kV, (42.0 kV MCOV) UH054A
60 kV, (48.0 kV MCOV) UH060A
66 kV, (53.0 kV MCOV) UH066A
B100-95023 19
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
VariSTAR Type AZG4 Surge I235-84 Overvoltage protection of Metal Oxide Station-Class, Ur Arrester Uc Arrester COV
Arresters for Systems through IS235-84-1 high-voltage systems through porcelain housed surge Rating (kV, rms) (kV, rms)
400 kV IEC 20-kA; Line Discharge 400 kV. arresters for overvoltage
Class 4 protection of substation 3 2.55 AZG4041G002003
electrical equipment. Metal 6 5.10 AZG4041G005006
top design, IEC Certified.
9 7.65 AZG4041G007009
10 8.40 AZG4042G008010
12 10.2 AZG4042G010012
15 12.7 AZG4042G012015
18 15.3 AZG4043G015018
21 17.0 AZG4043G017021
24 19.5 AZG4043G019024
27 22.0 AZG4044G022027
30 24.4 AZG4044G024030
33 27.5 AZG4044G027033
36 29.0 AZG4044G029036
39 31.5 AZG4045G031039
42 34.0 AZG4045G034042
45 36.5 AZG4045G036045
48 39.0 AZG4045G039048
54 42.0 AZG4046G042054
60 48.0 AZG4046G048060
66 53.0 AZG4047G053066
72 57.0 AZG4047G057072
78 62.0 AZG4048G062078
84 68.0 AZG4048G068084
90 70.0 AZG4048G070090
96 76.0 AZG4048G076096
108 84.0 AZG4049G084108
120 98.0 AZG4049G098120
132 106.0 AZG4052G106132
138 111.0 AZG4052G111138
144 115.0 AZG4053G115144
B100-95023 21
Product Catalog Typical Application Recommended Ratings Catalog Numbers
Section Spec Wording
UltraSIl Polymer-Housed I235-92 Ur Arrester Uc Arrester COV
VariSTAR Type U2 Surge Arrester IS235-92-1 Rating (kV, rms) (kV, rms)
(continued)
30 24.4 U203002418B5AAA
33 27.5 U203302718B5AAA
36 29.0 U203602918B5AAA
39 34.5 U203903120B5AAA
42 34.0 U204203422B5AAA
45 36.5 U204503622B5AAA
48 39.0 U204803926B5AAA
54 42.0 U205404226B5AAA
60 48.0 U206004830B5AAA
66 53.0 U206605338B5AAA
72 57.0 U207205740B5AAA
78 62.0 U207806242B5AAA
84 68.0 U208406846B5AAA
90 70.0 U209007046B5AAA
96 76.0 U209607648B5AA1
108 84.0 U210808454B5AA1
120 98.0 U21200986045AA1
132 106.0 U21321067645AA1
138 111.0 U21381117845AA1
144 115.0 U21441157845AA1
162 130.0 U21621308645AA1
168 131.0 U21681318645AA1
172 140.0 U21721408845AA1
180 144.0 U21801449045AA1
192 152.0 U2192152A445AA1
198 160.0 U2198160A845AA1
204 165.0 U2204165B045AA1
216 174.0 U2216174B445AA1
228 182.0 U2228182B645AA1
240 190.0 U2240190C045AA1
B100-95023 23
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
UltraSIl Polymer-Housed I235-93 162 130.0 U31621308645AA1
VariSTAR Type U3 Surge Arrester IS235-93-1
(continued) 168 131.0 U31681318645AA1
172 140.0 U31721408845AA1
180 144.0 U31801449045AA1
192 152.0 U3192152A445AA1
198 160.0 U3198160A845AA1
204 165.0 U3204165B045AA1
216 174.0 U3216174B445AA1
228 182.0 U3228182B645AA1
240 190.0 U3240190C045AA1
UltraSIL Polymer-Housed I235-94 Overvoltage protection of Station-Class, polymer-housed Ur Arrester Uc Arrester COV
VariSTAR Type U4 Surge Arrester IS235-94-1 high voltage class power and MOV arrester, for overvoltage Rating (kV, rms) (kV, rms)
for Systems through 275 kV IEC substation equipment. protection of electrical
20 kA; Line Discharge Class 4 equipment, IEC Certified. 3 2.55 U40030020845AAA
6 5.10 U40060051045AAA
9 7.65 U40090071045AAA
10 8.40 U40100081045AAA
12 10.2 U40120101245AAA
15 12.7 U40150121445AAA
18 15.3 U40180151445AAA
21 17.0 U40210171645AAA
24 19.5 U40240191845AAA
27 22.0 U40270221845AAA
30 24.4 U40300242045AAA
33 27.5 U40330272245AAA
36 29.0 U40360292245AAA
39 31.5 U40390312245AAA
42 34.0 U40420342445AAA
45 36.5 U40450362645AAA
48 39.0 U40480392645AAA
54 42.0 U40540422845AAA
60 48.0 U40600483045AAA
66 53.0 U40660534045AAA
72 57.0 U40720574445AAA
B100-95023 25
Fusing Products
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
Expulsion Fuses
Oil-immersed, Current-Sensing 240-31 Expulsion fuse used to protect Fuse link shall be mounted 10 A, 8.3 kV, 2000 A Interrupting 3437718C05M
Weak-Link Cartridge Fuse S240-31-1 CSP transformers and pad- under oil and clear overload
mounted transformers. currents, secondary faults, 15 A 3437718C07M
and primary faults through its 25 A 3437718C10M
maximum interrupting rating.
40 A 3437718C12M
65 A 3437718C16M
140 A 3437718C18M
10 A, 15.5 kV, 1000 A Interrupting 3437719C05M
15 A 3437719C07M
25 A 3437719C10M
40 A 3437719C12M
65 A 3437719C16M
140 A 3437719C18M
Oil-immersed, Dual-Sensing 240-32 Expulsion fuse used to protect Fuse shall be mounted under- 8 A, 8.3 kV, 2000 A Interrupting 3437722C05M
Weak-Link Cartridge Fuse S240-31-1 CSP transformer and pad- oil and operate due to high
mounted transformers currents and also operate due 15 A 3437722C08M
to high oil temperature, thus 25 A 3437722C10M
providing thermal protection to
the transformer. 40 A 3437722C12M
100 A 3437628C16M
140 A 3437628C18M
8 A, 15.5 kV, 1000 A Interrupting 3437723C05M
15 A 3437723C08M
25 A 3437723C10M
40 A 3437723C12M
100 A 3437629C16M
140 A 3437629C18M
Example: To order a two- or three- phase MagneX Interrupter without indicator, single-phase trip,
with float and E12 sensor, the catalog number would be MX3BN1SYE12.
(Refer to Catalog Section 240-33.)
Standard Options
Digits: 1 2 3 4 5 6 7 8 9 10 11
M X 3 B N 1 M D E 1 2
Sensor
System Size
Product Connection
MagneX D-Delta E01
Y-Wye E03
Note: For 2-Phase E06
Phases E10
2-Two MagneX must
be D E12
3-Three E18
E25
Trip Type E30
Indicator M-Multi-Phase Trip* E40
B-w/o Indicator S-Single-Phase Trip** E50
Note: For 2-Phase MagneX
must be M
Overload * If M, only select D for System
N-Non EO Connection (digit 8)
** If S, only select Y for System
Connection (digit 8)
Float
1-w/Float
2-w/o Float
Notes:
* For a Two-phase MagneX, digit 8 must be a D.
** For a Two-phase MagneX, digit 7 must be an M.
B100-95023 27
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
MagneX Interrupter with Indicator 240-34 Primary overcurrent protection Breaker shall be installed
S240-34-1 of pole-mounted and pad- on the primary side of
mounted single-phase transformer. Breaker shall have
transformer. the capability to energize and
de-energize the single-phase
transformer by one hotstick
operation.
Example: To order a single-phase MagneX Interrupter without indicator, single-phase trip, with float
and E12 sensor, the catalog number would be MX1BN1SYE12. (Refer to Catalog Section 240-
34.)
Standard Options Standard Options
EO
Digits: 1 2 3 4 5 6 7 8 9 10 11
M X 1 A E 1 S Y E 1 2
N
O
RM
O
PE
AL
N
CL
O
SE
D
System Sensor
Product Connection Size
MagneX Y-Wye E01
E03
Phases Trip Type E06
1-One S-Single-Phase Trip E10
E12
E18
Indicator Float E25
A-w/Indicator 1-w/Float E30
2-w/o Float E40
B-w/o Indicator
E50
Overload
E-EO
N-Non EO
Cover-Mounted Bay-O-Net 240-40 Bay-O-Net holder used for Bay-O-Net Assembly shall through 23 kV 4001177B51MC
Assembly S240-40-3 submersible transformers. mount in the cover of (short)
submersible transformers. 400177B53MC
(long)
Bay-O-Net Fuse Assembly Drip 240-41 Clamps on sidewall-mounted Drip Guard shall clamp onto 4004352B02
Guard Bay-O-Net Assembly. Catches the Bay-O-Net Housing and
oil emitted from tank during catch oil that may come out of
removal of Bay-O-Net Fuse the housing when the stabber
Holder. is removed.
Current Sensing Bay-O-Net Fuse 240-45 Field replaceable expulsion fuse Bay-O-Net mounted fuse link 6 A, Bay-O-Net Fuse 4000353C04B
Link S240-40-3 used for protecting deadfront shall clear overload currents,
pad-mounted transformers. secondary faults, and primary 10 A 4000353C06B
faults through its maximum 15 A 4000353C08B
interrupting rating.
25 A 4000353C10B
40 A 4000353C12B
65 A 4000353C14B
100 A 4000353C16B
140 A 4000353C17B
B100-95023 29
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
Dual Sensing Bay-O-Net Fuse 240-46 Field replaceable expulsion fuse Bay-O-Net mounted fuse link 3 A, Bay-O-Net Fuse 4000358C03B
Link S240-40-3 used for protecting deadfront shall clear overload currents,
pad-mounted transformers. secondary faults, and primary 8A 4000358C05B
Provides thermal protection to faults caused by high currents 15 A 4000358C08B
transformers. and also operate due to high
oil temperature, thus providing 25 A 4000358C10B
thermal protection to the 50 A 4000358C12B
transformer.
65 A 4000358C14B
100 A, Bay-O-Net Fuse Link with Integral 4000358C16CB
Cartridge and End Plug
140 A, Bay-O-Net Fuse Link with Integral 4000358C18CB
Cartridge and End Plug
Isolation Link 240-47 Used in series with Bay-O-Net Isolation link shall be Bay-O-Net Fuse Isolation Link
S240-40-3 Fuse or MagneX Interrupter. coordinated with the
(Bay-O-Net Melts open during transformer Bay-O-Net Fuse or MagneX Current Sensing Fuses
Fuse) failure so line person cant re- Interrupter to melt only when 4000353C04 3001861A01M
S240-34-1 energize failed transformer. a primary transformer failure 4000353C06 3001861A02M
(MagneX) occurs, preventing a line
person from re-energizing a 4000353C08 3001861A02M
faulted transformer. 4000353C10 3001861A03M
4000353C12 3001861A03M
4000353C14 3001861A05M
4000353C16 3001861A05M
4000353C17 3001861A05M
Dual Sensing Fuses
4000358C03 3001861A01M
4000358C05 3001861A02M
4000358C08 3001861A03M
4000358C10 3001861A05M
4000358C12 3001861A06M
4000358C14 3001861A07M
4000358C16CB 3001861A07M
4000358C18CB 3001861A07M
Dual Element Fuses
4038108C03 3001861A01M
4038108C04 3001861A01M
4038108C05 3001861A02M
4038108C06 3001861A02M
4038108C07 3001861A02M
4038108C09 3001861A03M
4038108C11 3001861A03M
4038108C12 3001861A03M
B100-95023 31
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
under-oil backup current-limiting fuses
ELSP Current-Limiting Backup 240-50 Used in series with low current The under-oil mounted backup 30 A, 8.3 kV 3543030M61M
Fuse S240-50-1 clearing device to provide current-limiting fuse 30-165A.
current-limiting transformer Fuse shall be used in series 40 A 3543040M61M
protection. with expulsion fuse and shall 50 A 3543050M61M
be properly coordinated to
operate when transformer is 65 A 3543065M61M
internally faulted. 80 A 3543080M71M
100 A 3543100M71M
125 A 3543125M71M
150 A 3543150M71M
165 A 3543165M71M
30 A, 15.5 kV 3544030M61M
40 A 3544040M61M
50 A 3544050M61M
65 A 3544065M51M
80 A 3544080M51M
100 A 3544100M51M
125 A 3544125M61M
150 A 3544150M51M
30 A, 23 kV 3545030M61M
40 A 3545040M61M
50 A 3545050M61M
65 A 3545065M51M
80 A 3545080M51M
100 A 3545100M71M
125 A 3545125M61M
150 A 3545150M51M
165 A 3545165M71M
clip-mounted current-limiting fuses
ELX Full-Range Current-Limiting 240-55 Used for pad-mounted Fuse shall provide full-range 3 A, 8.3 kV, Code 4, ELX Full-Range 3563003M11M
Fuse transformer protection. clearing capability and limit Current-Limiting Fuse
Mounted either in dry-well current and energy let-through
canister (deadfront) or in clip when operating due to high 6A 3563006M11M
contacts (livefront). currents. Fuse shall not emit 8A 3563008M11M
gases when it operates, thus,
making it suitable for drywell
canister applications.
B100-95023 33
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
X-Limiter Full-Range Current- 240-56 Used for pad-mounted Fuse shall provide full-range 8 A, 4.3 kV, Code 4, X-Limiter Clip-Style 43F008-I
Limiting Fuse S240-56-1 transformer protection. current-clearing capability, Fuse without indicator
Mounted in clip contacts and limit current and energy
(livefront). let-through to the system 10 A 43F010-I
when operating due to primary 12 A 43F012-I
transformer faults. Fuse
shall not emit gases when it 18 A 43F018-I
operates. Optional indicator is 25 A 43F025-I
required.
35 A 43F035-I
45 A 43F045-I
50 A 43F050-I
65 A 43F065-I
75 A 43F075-I
100 A 43F100-I
6 A, 5.5 kV, Code 4, X-Limiter Clip-Style 55F006-I
Fuse without indicator
8A 55F008-I
10 A 55F010-I
12 A 55F012-I
18 A 55F018-I
20 A 55F020-I
25 A 55F025-I
30 A 55F030-I
40 A 55F040-I
50 A 55F050-I
65 A 55F065-I
75 A 55F075-I
3 A, 8.3 kV, Code 4, X-Limiter Clip-Style 83F003-I
Fuse without indicator
6A 83F006-I
8A 83F008-I
10 A 83F010-I
12 A 83F012-I
18 A 83F018-I
20 A 83F020-I
25 A 83F025-I
30 A 83F030-I
40 A 83F040-I
B100-95023 35
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
X-Limiter Full-Range Current- 240-56 30 A 23F030-I
Limiting Fuse S240-56-1
(continued) 40 A 23F040-I
50 A 23F050-DW
50 A, 23 kV, Code 9, X-Limiter Clip- 23F050-I
Style Fuse without Indicator
65 A 23F065-I
80 A 23F080-I
100 A 23F100-I
130 A, 4.3 kV, Unitized X-Limiter Fuse 43F130-UI
Refill Units with Indicator
150 A 43F150-UI
200 A 43F200-UI
100 A, 5.5 kV, Unitized X-Limiter Fuse 55F100-UI
Refill Units with Indicator
130 A 55F130-UI
150 A 55F150-UI
60 A, 8.3 kV, Unitized X-Limiter Fuse 83F060-UI
Refill Units with Indicator
80 A 83F080-UI
100 A 83F100-UI
60 A, 15.5 kV, Unitized X-Limiter Fuse 155F060-UI
Refill Units with Indicator
80 A 155F080-UI
100 A 155F100-UI
B100-95023 37
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
Current-Limiting Fuse Holders 240-59 8.3 kV, 95 kV BIL, Code 1, FAA1D1
(continued) Single-Phase, Hinge-Style Mounting
with 180 Stop
15.5 kV, 95 kV BIL, Code 2 with 180 FAA1D2
Stop
8.3 kV, 95 kV BIL, Code 1, FAB1D1
Single-Phase, Hinge-Style Mounting
with 180 Stop
15.5 kV, 95 kV BIL, Code 5 FAB1D2
15.5 kV, 95 kV BIL, Code 6 FAB1D5
(with FA17X Mounting Base)
15.5 kV, 95 kV BIL, Code 6 FAB1D10
(with FA406X Mounting Base)
15.5 kV, 125 kV BIL, Code 5 FAB1D4
15.5 kV, 125 kV BIL, Code 6 FAB1D8
(with FA17X Mounting Base)
15.5 kV, 125 kV BIL, Code 6 FAB1D11
(with FA406X Mounting Base)
23 kV, 125 kV BIL, Code 6 FAB1D9
23 kV, 150 kV BIL, Code 6 FAB1D3
27 kV, 150 kV BIL, Code 9 FAB1D6
38 kV, 150 kV BIL, Code 10 FAB1D7
8.3 kV, 95 kV BIL, Code 4, Single-Phase, FAB1K1
Clip-Style Mounting for Parallel Fuses
15.5 kV, 95 kV BIL, Code 5 FAB1K2
15.5 kV, 125 kV BIL, Code 5 FAB1K3
15.5 kV, 95 kV BIL, Code 6 FAB1K4
15.5 kV, 95 kV BIL, Code 6 FAB1K5
27 kV, 150 kV BIL, Code 9 FAB3K1
38 kV, 150 kV BIL, Code 10 FAB3K2
Insulators
95 kV BIL, Indoor, Standoff Insulator FM2A1C
125 kV BIL FM2A3C
150 kV BIL FM2A2C
95 kV BIL, Outdoor, Standoff Insulator FM10A1C
Tandem NX, Switch/Fuse Mounting, 8.3 FAJ1D1
kV, 95 kV BIL, Code 1/5
Tandem NX, Switch/Fuse Mounting, FAJ1D2
15.5 kV, 95 kV BIL, Code 1/6
B100-95023 39
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
NX Indoor Full-Range Current- 240-60 30 A FA2A30
Limiting Fuse S240-60-1
(continued) 40 A FA2A40
50 A FA2A50
65 A FA2A65
75 A FA2A75
1.5 A, 8.3 kV, Code 1, NX, Hinge-Style FA3A1
Fuse with Arc-Strangler loadbreak
device
3A FA3A3
4.5 A FA3A4
6A FA3A6
8A FA3A8
10 A FA3A10
12 A FA3A12
18 A FA3A18
20 A FA3A20
25 A FA3A25
30 A FA3A30
40 A FA3A40
1.5 A, 15.5 kV, Code 2, NX, Hinge- FA4A1
Style Fuse with Arc-Strangler loadbreak
device
3A FA4A3
4.5 A FA4A4
6A FA4A6
8A FA4A8
10 A FA4A10
12 A FA4A12
18 A FA4A18
20 A FA4A20
25 A FA4A25
30 A FA4A30
40 A FA4A40
8.3 kV, 200 A Code 1, NX, Arc- FA1B1
Strangler Switchblade
15.5 kV, 200 A Short Blade, Code 1, FA4B1
NX, Arc-Strangler Switchblade
15.5 kV, 200 A Long Blade, Code 2, FA3B1
NX, Arc-Strangler Switchblade
B100-95023 41
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
NX Indoor Full-Range Current- 240-60 25 A FA3H25
Limiting Fuse S240-60-1 30 A FA3H30
(continued)
40 A FA3H40
50 A, 8.3 kV, Code 5, NX, Clip-Style FA3H50
Fuse with Indicator
65 A FA3H65
80 A FA3H80
100 A FA3H100
1.5 A, 15.5 kV, Code 5, NX, Clip-Style FA4H1
Fuse with Indicator
3A FA4H3
4.5 A FA4H4
6 A, 15.5 kV, Code 5, NX, Clip-Style FA4H6
Fuse with Indicator
8A FA4H8
10 A FA4H10
12 A FA4H12
18 A FA4H18
20 A FA4H20
25 A FA4H25
30 A FA4H30
40 A FA4H40
50 A, 15.5 kV, Code 6, NX, Clip-Style FA4H50
Fuse with Indicator
65 A FA4H65
80 A FA4H80
100 A FA4H100
6 A, 23 kV, Code 6, NX, Clip-Style Fuse FA5H6
with Indicator
8A FA5H8
10 A FA5H10
12 A FA5H12
18 A FA5H18
20 A FA5H20
25 A FA5H25
B100-95023 43
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
NXC Full-Range Capacitor Fuse 240-61 Individually Fused Capacitor A full-range current-limiting 10 A, 8.3 kV, NXC, Capacitor Fuse FA5J10
S240-61-1 Protection fuse with both low and high
current clearing sections in 18 A FA5J18
one housing shall be used to 25 A FA5J25
individually fuse capacitors.
The fuse shall have an 30 A FA5J30
automatic leader ejection 40 A FA5J40
feature to provide visible
indication of fuse operation, 45 A FA5J45
without the use of hinges, 65 A FA5J65
flippers, or other mechanical
devices. 10 A, 15.5 kV FA6J10
12 A FA6J12
18 A FA6J18
25 A FA6J25
30 A FA6J30
35 A FA6J35
12 A, 23 kV FA7J12
18 A FA7J18
25 A FA7J25
Direct-Connected Capacitor Fuse 240-63 Used for fusing individual or Fuse shall provide full-range 10 A, 4.3 kV, Indoor Bolt Tab Fuse with 43F010-IV
S240-63-1 group connected capacitors. protection and be current- High View Indicator
limiting. Both low current and 12 A 43F012-IV
high current clearing sections
shall be inside one housing. All 18 A 43F018-IV
gases generated during fuse 25 A 43F025-IV
operation shall be contained
within the fuses housing. 35 A 43F035-IV
45 A 43F045-IV
50 A 43F050-IV
65 A 43F065-IV
75 A 43F075-IV
100 A 43F100-IV
130 A, 4.3 kV, Indoor Parallel-Mounted 43F130-IVBTU
Fuse with High View Indicator
150 A 43F150-IVBTU
200 A 43F200-IVBTU
18 A, 5.5 kV, Indoor Bolt Tab Fuse with 55F018-IV
High View Indicator
20 A 55F020-IV
25 A 55F025-IV
30 A 55F030-IV
40 A 55F040-IV
B100-95023 45
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
Direct-Connected Capacitor Fuse 240-63 6 A, 23 kV, Indoor Bolt Tab Fuse with 23F006-IVBTB
(continued) S240-63-1 High View Indicator
8A 23F008-IVBTB
10 A 23F010-IVBTB
12 A 23F012-IVBTB
18 A 23F018-IVBTB
20 A 23F020-IVBTB
25 A 23F025-IVBTB
30 A 23F030-IVBTB
40 A 23F040-IVBTB
50 A 23F050-IVBTB
EL Bay-O-Net Current-Limiting 240-70 Used to mount the ELS fuse A Bay-O-Net assembly shall Assembly with 1/4 inch Gasket 4004697B01M
Fuse Assembly S240-70-1 for pad-mounted transformer be used to mount a full range
protection. current-limiting, under-oil Assembly with 3/16 inch Gasket 4004697B02M
mounted fuse. Bay-O-Net Solid Link Disconnect 4025117B51
assembly shall include field
replaceability of current-limiting 15.5 and 23.0 kV
fuse. Assembly with 1/4 inch Gasket 4004697B03M
Assembly with 3/16 inch Gasket 4004697B04M
Solid Link Disconnect 4025117B52
B100-95023 47
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
15 and 25 kV Class Fused 240-97 For protecting underground Fuse shall provide full-range 8.3 kV Fuse Rating/15.5 kV System Class
Loadbreak Elbow Current-Limiting S240-97-1 distribution systems as part of a current-carrying capability, and
fused elbow. 6A FEF083A006
Fuse limit current and energy let-
through to the system when 8A FEF083A008
operating due to a primary
fault. Must be installed in a 10 A FEF083A010
Cooper fused elbow assembly. 12 A FEF083A012
18 A FEF083A018
20 A FEF083A020
25 A FEF083A025
30 A FEF083A030
40 A FEF083A040
15.5 kV Fuse Rating/25 kV System Class
6A FEF155A006
8A FEF155A008
10 A FEF155A010
12 A FEF155A012
18 A FEF155A018
20 A FEF155A020
B100-95023 49
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
ELSG Full-Range Current-Limiting 240-82 15.5 kV E-Rated Fuse For 25 & 35 kV Wetwell Holder
Fuse S240-82-1
(continued) 4 E, 9 A Continuous Rating 3594004M02M
8 E, 14 A Continuous Rating 3594008M02M
12 E, 18 A Continuous Rating 3594012M02M
15 E, 24 A Continuous Rating 3594015M02M
20 E, 34 A Continuous Rating 3594020M02M
25 E, 35 A Continuous Rating 3594025M02M
30 E, 46 A Continuous Rating 3594030M02M
40 E, 53 A Continuous Rating 3594040M02M
50 E, 65 A Continuous Rating 3594050M02M
60 E, 76 A Continuous Rating 3594060M02M
65 E, 95 A Continuous Rating 3594065M01M
80 E, 125 A Continuous Rating 3594080M01M
100 E, 140 A Continuous Rating 3594100M01M
120 E, 150 A continuous Rating 3594120M02M
150 E, 200 A Continuous Rating 3594150M02M
15.5 kV Rated Fuse, MSLE Version
50 A, Continuous, Equivalent to A.B. 3594050MSLE
Chances SL-54 Fuse Rating
90 A, Continuous, Equivalent to A.B. 3594090MSLE
Chances SL-90 Fuse Rating
23 kV E-Rated Fuse For 25 & 35 kV Wetwell Holder
4 E, 9 A Continuous Rating 3595004M02M
8 E, 14 A Continuous Rating 3595008M02M
12 E, 18 A Continuous Rating 3595012M02M
15 E, 24 A Continuous Rating 3595015M02M
20 E, 34 A Continuous Rating 3595020M02M
25 E, 35 A Continuous Rating 3595025M02M
30 E, 46 A Continuous Rating 3595030M02M
40 E, 53 A Continuous Rating 3595040M02M
65 E, 120 A Continuous Rating 3595065M02M
80 E, 145 A Continuous Rating 3595080M02M
100 E, 180 A Continuous Rating 3595100M02M
23 kV Rated Fuse, MSLE Version
50 A Continuous, Equivalent to A.B. 3595050MSLE
Chance's SL-54 Fuse Rating
90 A Continuous, Equivalent to A.B. 3595090MSLE
Chance's SL-90 Fuse Rating
135 A Continuous Rating 3595135MSLE
50 OEM Product Guide November 2010 Supersedes 95023, 10/01
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
X-Limiter Hinge-Mount Current- 240-84 Provides current-limiting Fuse shall provide full-range 10 A, 8.3 kV X-Limiter Hinge-Mounted 83F010HD1A
Limiting Fuse S240-84-1 protection when mounting in clearing capability. Fuse Fuse to Fit S & C 14.4 kV (17.0 kV)
S240-84-2 S & C indoor and outdoor SM, shall limit energy and current Type SMD-20 Outdoor Mount
S240-84-3 SMD, and SME mountings. let-through to system when (S & C End Fittings Part No. 3095)
operating for high current
faults. Fuse shall support 12 A 83F012HD1A
system voltage during current 18 A 83F018HD1A
clearing of high current
faults. All gases generated 20 A 83F020HD1A
during fuse operations shall 25 A 83F025HD1A
be contained within the fuse
housing. 30 A 83F030HD1A
40 A 83F040HD1A
50 A 83F050HD1A
65 A 83F065HD1A
80 A 83F080HD1A
100 A 83F100HD1A
125 A 83F125HD1A
140 A 83F140HD1A
10 A, 15.5 kV X-Limiter Hinge-Mounted 15F010HD1A
Fuse to Fit S & C 14.4 kV (17.0 kV)
Type SMD-20 Outdoor Mount
(S & C End Fittings Part No. 3095)
12 A 15F012HD1A
18 A 15F018HD1A
20 A 15F020HD1A
25 A 15F025HD1A
30 A 15F030HD1A
40 A 15F040HD1A
50 A 15F050HD1A
65 A, 17 kV X-Limiter Hinge-Mounted 15F065HD1A
Fuse to Fit S & C 14.4 kV (17.0 kV)
Type SMD-20 Outdoor Mount
(S & C End Fittings Part No. 3095)
80 A 15F080HD1A
100 A 15F100HD1A
10 A, 15.5 kV X-Limiter Hinge-Mounted 15F010HD2A
Fuse to Fit S & C kV (27.0 kV) Type
SMD-20 Outdoor Mount
(S & C End Fittings Part No. 3095)
12 A 15F012HD2A
18 A 15F018HD2A
20 A 15F020HD2A
25 A 15F025HD2A
B100-95023 51
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
X-Limiter Hinge-Mounted Current- 240-84 30 A 15F030HD2A
Limiting Fuse S240-84-1
(continued) S240-84-2 40 A 15F040HD2A
S240-84-3 50 A 15F050HD2A
65 A 15F065HD2A
80 A 15F080HD2A
100 A 15F100HD2A
125 A 15F125HD2A
10 A, 23 kV X-Limiter Hinge-Mounted 23F010HD2A
Fuse to Fit S & C 25 kV (27 kV) Type
SMD-20 Outdoor Mount
(S & C End Fittings Part No. 3095)
12 A 23F012HD2A
18 A 23F018HD2A
20 A 23F020HD2A
25 A 23F025HD2A
30 A 23F030HD2A
40 A 23F040HD2A
50 A 23F050HD2A
10 A, 23 kV X-Limiter Hinge-Mounted 23F010HD3A
Fuse to Fit S & C 34.5 kV (38.0kV) Type
SMD-20 Outdoor Mount
(S & C End Fittings Part No. 3095)
12 A 23F012HD3A
18 A 23F018HD3A
20 A 23F020HD3A
25 A 23F025HD3A
30 A 23F030HD3A
40 A 23F040HD3A
50 A 23F050HD3A
20 A, 8.3 kV X-Limiter Fuse with Upper 83F020HZ1IEF
Contact and Lower Hinge Assembly to
Fit S & C 14.4 kV (17.0 kV) Type SML-
4Z Indoor Mount
25 A 83F025HZ1IEF
30 A 83F030HZ1IEF
80 A 83F080HZ1IEF
50 A, 15 kV X-Limiter Fuse With Upper 15F050HZ2IEF
Contact and Lower Hinge Assembly to
Fit S & C 25 kV (27 kV) Type SML-4Z
Indoor Mount
B100-95023 53
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
X-Limiter Hinge-Mounted Current- 240-84 30 A 15F030HC1A
Limiting Fuse S240-84-1
(continued) S240-84-2 40 A 15F040HC1A
S240-84-3 50 A 15F050HC1A
65 A 15F065HC1A
80 A 15F080HC1A
20 A, 15 kV X-Limiter Fuse to Fit S & 15F020VHA1A
C 14.4 kV (17.0 kV) Type SM-4 Indoor
Mount
(S & C End Fittings No. 87119)
25 A 15F025VHA1A
30 A 15F030VHA1A
40 A 15F040VHA1A
50 A 15F050VHA1A
65 A 15F065VHA1A
80 A 15F080VHA1A
20 A, 15.5 kV X-Limiter Fuse to Fit S 15F020VHA2A
& C 25 kV (27.0 kV) Type SM-4 Indoor
Mount
(S & C End Fittings No. 87119)
25 A 15F025VHA2A
30 A 15F030VHA2A
40 A 15F040VHA2A
50 A 15F050VHA2A
65 A 15F065VHA2A
80 A 15F080VHA2A
Edison Modular Fuse (EMF) 240-92 Insulated in-line fuse for use Fuse shall be fully shielded Consult Factory for Product Information
S240-92-1 in deadfront, overhead or and insulated. Fuse consists of
underground, submersible Cooper Power Systems Fuse
cable distribution system. Ideal encapsulated in EDPM rubber.
for vault applications. Mounting brackets shall be
made with stainless steel.
B100-95023 55
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
CMU Power Fuse 240-94 CMU-20, 17 kV
(continued) S240-94-1
15 A, SE CMU712015
20 A, SE CMU712020
25 A, SE CMU712025
30 A, SE CMU712030
40 A, SE CMU712040
50 A, SE CMU712050
65 A, SE CMU712065
80 A, SE CMU712080
100 A, SE CMU712100
125 A, SE CMU712125
150 A, SE CMU712150
175 A, SE CMU712175
200 A, SE CMU712200
CMU-20, 27 kV
3 A, K CMU703003
6 A, K CMU703006
8 A, K CMU703008
10 A, K CMU703010
12 A, K CMU703012
15 A, K CMU703015
20 A, K CMU703020
25 A, K CMU703025
30 A, K CMU703030
40 A, K CMU703040
50 A, K CMU703050
65 A, K CMU703065
80 A, K CMU703080
100 A, K CMU703100
140 A, K CMU703140
200 A, K CMU703200
CMU-20, 27 kV
5 A, E CMU613005
7 A, E CMU613007
10 A, E CMU613010
B100-95023 57
Catalog Recommended
Product Typical Application Ratings Catalog Numbers
Section Spec Wording
CMU Power Fuse 240-94 20 A, K CMU704020
(continued) S240-94-1 25 A, K CMU704025
30 A, K CMU704030
40 A, K CMU704040
50 A, K CMU704050
65 A, K CMU704065
80 A, K CMU704080
100 A, K CMU704100
140 A, K CMU704140
200 A, K CMU704200
CMU-20, 38 kV
5 A, E CMU614005
7 A, E CMU614007
10 A, E CMU614010
13 A, E CMU614013
15 A, E CMU614015
20 A, E CMU614020
25 A, E CMU614025
30 A, E CMU614030
40 A, E CMU614040
50 A, E CMU614050
65 A, E CMU614065
80 A, E CMU614080
100 A, E CMU614100
125 A, E CMU614125
150 A, E CMU614150
175 A, E CMU614175
200 A, E CMU614200
CMU-20, 38 kV
15 A, SE CMU714015
20 A, SE CMU714020
25 A, SE CMU714025
30 A, SE CMU714030
40 A, SE CMU714040
50 A, SE CMU714050
B100-95023 59
Transformer Components
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Low Voltage (Secondary) Bushings
Molded (HTN) Tri-Clamp 5/8 & 1 800-14 Externally mounted and The secondary bushing shall 600 A - 1400 A 1.2 kV Class
S800-16-1 removable secondary bushings be externally removable, one-
used for connecting low piece copper conductor with 5/8 inch-11 w/1.75 inch External 2690286D01
voltage cables outside of the HTN (high temperature nylon) Threaded Stud and 1.4 inch Internal
pad-mounted transformer tank insulated body. Threaded Stud, Copper-600 A
to the winding leads inside the 5/8 inch-11 w/1.75 inch External 2690286D06
tank. Designed for under-oil Threaded Stud and Internal Spade
usage. w/0.44 inch Dia. Hole, Copper-600 A
1 inch-14 w/1.75 inch External 2690286D07
Threaded Stud and Internal Spade
w/0.44 inch Dia. Hole, Copper-1400 A
1 inch-14 w/2.25 inch External 2690286D08
Threaded Stud and Internal Spade
w/0.44 inch Dia. Hole, Copper-1400 A
1 inch-14 w/1.75 inch External and 2690286D09
Internal Threaded Stud Copper-1400 A
1 inch-14 w/1.75 inch External 2690286D10
Threaded Stud and Internal Spade
w/0.53 inch Dia. Hole, Copper-1400 A
1 inch-14 w/3.00 inch External 2690286D22
Threaded Stud and Internal Threaded
Stud, Copper-1400 A
5/8 inch-11 w/2.13 inch External 2690286D23
Threaded Stud and Internal Spade
w/0.44 inch Dia. Hole, Copper-600 A
1 inch-14 w/3.05 inch External 2690286D24
Threaded Stud and Internal Spade
w/0.44 inch Dia. Hole, Copper-1400 A
Gasket 0537980C20
B100-95023 61
Product Catalog Typical Application Recommended Rating/Description Catalog Numbers
Section Spec Wording
HIGH VOLTAGE (PRIMARY) BUSHINGS
Plastic (HTN) Molded TRI- 800-32 Externally mounted & The 200 A Bushing well 200 A, 35 kV BW150F (Fixed Stud
Clamp Bushing Well W/Fixed or S800-35-2 removable well for termination shall have either a fixed or a BW150R
Removable Stud of primary coil winding leads at removable stud, be externally (Removable Stud)
the frontplate of pad-mounted removable, molded with High
transformers. A bushing Temperature Nylon (HTN) 35
or feedthru insert must be kV, 150 kV BIL Rated with
installed for connection of high- integral clamp, and have a
voltage (primary) cable to the molded-in semi-conductive
transformer. shield. The removable stud
shall have provisions for easy
removal of broken parts from
both the well & insert.
Plastic (HTN) Molded Bushing 800-33 Externally mounted & The 200 A Bushing well 200 A, 15, 25, & 28 kV 2638372C01 (Fixed
Well with Fixed or Removable S800-35-2 removable well for termination shall have either a fixed or a Stud)
Stud of primary coil winding leads at removable stud, be externally 2638372C02R
the frontplate of pad-mounted removable, molded with High (Removable Stud)
transformers. A bushing Temperature Nylon (HTN) 28
or feedthru insert must be kV rated and have a molded-in
installed for connection of high- semi-conductive shield. The
voltage (primary) cable to the removable stud shall have
transformer. provisions for easy removal
of broken parts from both the
well & insert.
Plastic (HTN) Molded Bushing 800-33 The 200 A Bushing well 200 A, 35 kV 2638372C01S
Well with Fixed or Removable S800-35-2 shall have either a fixed or (Fixed Stud)
Stud removable stud, be externally 2638372C02RS
removable, molded with High (Removable Stud)
Temperature Nylon (HTN) 35
kV, 150 BIL Rated, and have
a molded-in semi-conductive
shield. The removable stud
shall have provisions for easy
removal of broken parts from
both the well & insert.
B100-95023 63
Catalog Recommended
Product Typical Application Rating/Description Catalog Numbers
Section Spec Wording
ARRESTER DISCONNECTOR
Under-oil Arrester Disconnector 800-51 Provides the transformer The under-oil arrester 35 kV AD150PA100 (w/std.
S800-51-1 manufacturer or utility with a disconnector shall be installed locking provision),
means of disconnecting and in an industry std. 1.325 Internally Secured
reconnecting the under-oil dia., keyed (0.14 radius) hole
arrester ground for transformer from the inside of the tank. It AD150NA100 (no
testing. Designed for under-oil shall be internally or externally locking provision),
usage. secured & positively grounded Internally Secured
w/metal UL approved electrical
grounding conduit lock nut. AD150PA200 (w/std.
locking provision),
Externally Secured
AD150NA200 (no
locking provision),
Externally Secured
SWITCHES
Externally Operated One-, Two- 800-57 Externally operated switch The Tap Changer Switch shall Single-Phase, 5 Positions
and Three-Phase Tap Changer S800-57-1 used to regulate induced be externally operated, snap
Switch voltage of transformer, allowing action switch with a choice Bolt Tab - Bent 90 (Accepts 1/4 2237500C01
100 A, 150 kV BIL changes in primary voltage to of the following operating Hardware)
maintain constant secondary systems:
voltage of pole or pad-mounted Cap wrench 16-14 AWG Terminals 2237500C02
transformers. Lever Handle 12-10 AWG Terminals 2237500C03
Hotstick handle (flexible or
rigid)
3
B100-95023 65
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Externally Operated Tap Changer 800-58 Externally operated switch The Tap Changer Switch shall Single-Phase Sidewall Mounted
Switch. 150 A, 150 kV BIL S800-58-1 used to regulate induced be externally operated, snap
voltage of transformer, allowing action switch with a choice 5 Position, Bolt Tab 2237470C01M
changes in primary voltage to of the following operating 5 Position, 16-14 AWG Terminals 2237470C02M
maintain constant secondary systems:
voltage of pole- or pad- Lever Handle 5 Position, 12-10 AWG Terminals 2237470C03M
mounted transformers. Hotstick handle
Padlocking provisions are 5 Position, 8 AWG Terminals 2237470C04M
available for lever or hotstick 5 Position, 6 AWG Terminals 2237470C05M
operable handles.
5 Position, Bolt Tab with 1/4 - 20 2237470C16M
Threaded Stud
5 Position, Bolt Tab with 1/4 - 20 2237470C70M
Threaded Stud, Silver Pltd.
7 Position, Bolt Tab 2237470C51M
7 Position, 16-14 AWG Terminals 2237470C52M
7 Position, 12-10 AWG Terminals 2237470C53M
7 Position, 8 AWG Terminals 2237470C54M
7 Position, 6 AWG Terminals 2237470C55M
7 7 Position, Bolt Tab with 1/4 - 20 2237470C66M
Threaded Stud
5
6
Three-Phase Sidewall Mounted
3
2
5 Position, Bolt Tab 2237471C01M
8
5 Position, 16-14 AWG Terminals 2237471C02M
5 Position, 12-10 AWG Terminals 2237471C03M
5 Position, 8 AWG Terminals 2237471C04M
5 Position, 6 AWG Terminals 2237471C05M
5 Position, Bolt Tab with 1/4 - 20 2237471C16M
Threaded Stud
5 Position, Bolt Tab with 1/4 1/4 - 20 2237471C70M
Threaded Stud, Silver Pltd.
7 Position, Bolt Tab 2237471C51M
7 Position, 16-14 AWG Terminals 2237471C52M
7 Position, 12-10 AWG Terminals 2237471C53M
7 Position, 8 AWG Terminals 2237471C54M
7 Position, 6 AWG Terminals 2237471C55M
7 Position, Bolt Tab with 1/4 - 20 2237471C66M
Threaded Stud
7 Position, Bolt Tab with 1/4 - 20 2237471C80M
Threaded Stud, Silver Pltd.
Special, 6 Deck Switch, 5 Position, Bolt 2237529C01M
Tab
Special, 6 Deck Switch, 7 Position, Bolt 2237529C51M
Tab
66 OEM Product Guide November 2010 Supersedes 95023, 10/01
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Externally Operated Tap Changer 800-58 Special, 6 Deck Switch, 5 Position, Bolt 2237529C16M
Switch, 150 A, 150 kV BIL S800-58-1 Tab with 1/4 - 20 Threaded Stud
(continued)
Special, 6 Deck Switch, 7 Position, Bolt 2237529C66M
Tab with 1/4 - 20 Threaded Stud
Single-Phase Cover-Mounted
5 Position, Bolt Tab 2237472C01M
5 Position, 16-14 AWG Terminals 2237472C02M
5 Position, 12-10 AWG Terminals 2237472C03M
5 Position, 8 AWG Terminals 2237472C04M
5 Position, 6 AWG Terminals 2237472C05M
5 Position, Bolt Tab with 1/4 - 20 2237472C16M
Threaded Stud
5 Position, Bolt Tab with 1/4 - 20 2237471C70M
Threaded Stud, Silver Pltd.
7 Position, Bolt Tab 2237472C51M
7 Position, 16-14 AWG Terminals 2237472C52M
7 Position, 12-10 AWG Terminals 2237472C53M
7 Position, 8 AWG Terminals 2237472C54M
7 Position, 6 AWG Terminals 2237472C55M
7 Position, Bolt Tab with 1/4 - 20 2237472C66M
Threaded Stud
Three-Phase Cover-Mounted
5 Position, Bolt Tab 2237473C01M
5 Position, 16-14 AWG Terminals 2237473C02
5 Position, 12-10 AWG Terminals 2237473C03M
5 Position, 8 AWG Terminals 2237473C04M
5 Position, 6 AWG Terminals 2237473C05M
5 or 7 Position, Bolt Tab with 1/4 - 20 2237473C16M
Threaded Stud
5 or 7 Position, Bolt Tab with 1/4 - 20 2237473C80M
Threaded Stud, Silver Pltd.
7 Position, Bolt Tab 2237473C51M
7 Position, 16-14 AWG Terminals 2237473C52M
7 Position, 12-10 AWG Terminals 2237473C53M
7 Position, 8 AWG Terminals 2237473C54M
7 Position, 6 AWG Terminals 2237473C55M
B100-95023 67
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Externally Operated Tap Changer 800-60 Externally operated switch The Tap Changer Switch shall 300A, 35kV: 2237179C01M
Switch. 300 A, 150 kV BIL S800-60-1 used to regulate induced be externally operated, with (Single-Phase) (1-Phase)
voltage of transformer, allowing all silver plated contacts, snap (Two-Phase) 2237179C04M
changes in primary voltage to action switch with a choice (Three-Phase) (2-Phase)
maintain constant secondary of the following operating 2237179C02M
voltage of pole- or pad- systems: (3-Phase)
mounted transformers. Lever Handle
Hotstick handle
Padlocking provisions are
available for lever or hotstick
operable handles.
Sectionalizing (Loadbreak) Switch 800-64 Under-oil used in underground Single loadbreak switch with FOUR-POSITION SECTIONALIZING LOADBREAK SWITCHES
S800-64-2 residential applications with capability of switching on and HORIZONTAL-MOUNTED , 12.5 KA,15.5 kV, 27.8 kV and 38
loopfeed, and in industrial off a primary cable tap and/or kV
installations where the ability provides capability to switch to 630 A, 300 A and 200 A, 95 kV BIL, 125 kV BIL, 150 kV BIL
to use an alternative source of an alternative source of power
power is necessary. Also used when necessary or desired. Single-Phase
to switch on and off a primary Must have make-before-break
cable tap on a transformer. capabilities for V and T Straight Blade, On/Off LS4BH1S12B
blade options as needed. Selector Side LS4BH1D12B
Selector Center LS4BH1R12B
Selector On/Off LS4BH1L12B
V-blade LS4BH1V12B
T-blade LS4BH1T12B
Make-Before-Break Switches:
V-blade LS4BH1V12M
T-blade LS4BH1T12M
Two-Phase
Straight Blade, On/Off LS4BH2S12B
Selector Side LS4BH2D12B
Selector Center LS4BH2R12B
Selector On/Off LS4BH2L12B
V-blade LS4BH2V12B
T-blade LS4BH2T12B
B100-95023 69
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Sectionalizing (Loadbreak) Switch 800-64 Make-Before-Break Switches:
(continued) S800-64-2
V-blade LS4BH2V16M
T-blade LS4BH2T16M
Three-Phase
Straight Blade, On/Off LS4BH3S16B
Selector Side LS4BH3D16B
Selector Center LS4BH3R16B
Selector On/Off LS4BH3L16B
V-blade LS4BH3V16B
T-blade LS4BH3T16B
Make-Before-Break Switches:
V-blade LS4BH3V16M
T-blade LS4BH3T16M
NOTE:
For Ring-mounted, replace the B with an R in the 4th digit
of the P/N.
VERTICAL-MOUNTED, 16 kA 15 kV, 24 kV and 36 kV 630 A,
400 A and 200 A
To order a vertical-mounted 16 kA switch - replace the H with
a V in the 5th digit of the P/N (ie: LS4BV3T16B)
1 2 3 4 5 6 7 8 9 10 11 12
L S 2 R 3 3 8 H 3 N 1 A
CODE PRODUCT CODE POWER RATING CODE STYLE**
L LOADBREAK 338 300 A, 38 kV N NORMAL
S SWITCH 427 400 A, 27 kV STAINLESS STEEL/
S NON-CORROSIVE
2 2-POSITION 515 550 A, 15 kV
646 65 A, 46 kV CODE INDICATOR PLATE*
CODE INSTALLATION 1 NO INDICATOR PLATE
R RING MOUNT SYSTEM WITH OPTIONAL
CODE ORIENTATION
W Weld-In Mount 2 INDICATOR PLATE
H HORIZONTAL (Indicator plate not available for
Weld-In system)
* Normal style switch has all externally located parts built from plated steel, aluminum and brass materials.
** Stainless Steel/non-corrosive style switch has all externally located parts built from stainless steel and brass materials.
** Stainless steel/non-corrosive style ring mount switch should always be matched with a hardware kit having a brass handle and a
stainless steel nut.
Digit 12 should always be "B", if digit 10 is "S", (for ring mount).
NOTE: Catalog Number Example shown represents a standard, ring mount system, 300 A, 38 kV, horizontal, three-phase, standard plated steel
external parts, w/o indicator plate, with brass handle hardware kit, 6:00/9:00 positions. (Other handle position options available upon request for
9:00/12:00, 12:00/3:00, and 3:00/6:00 positions. Consult your Cooper Power Systems sales representative for details.)
B100-95023 71
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Two-Position Cover-Mounted 800-65 Compact, under-oil two- On/off vertically-mounted
Loadbreak Switch, 200 kV BIL S800-65-2 position loadbreak/loadmake single-, two- or three-phase
switch for pad-mounted loadbreak switch. Must
transformers or distribution conform to IEEE Std C37.71
switchgear. standard and IEEE Std
C37.72 standard (Latest
Revision)
1 2 3 4 5 6 7 8 9 10 11 12
L S 2 W 3 3 8 F 3 S 1 B
CODE PRODUCT CODE POWER RATING CODE STYLE**
L LOADBREAK 338 300 A, 38 kV STAINLESS
S
S SWITCH 427 400 A, 27 kV STEEL
3 THREE
CODE HARDWARE KITS
CODE Vertical ORIENTATION A HARDWARE KIT
S Short - 1/2 Deck extension W/BRASS HANDLE
F Full - Full Deck Extension RING MOUNT ONLY -
B HARDWARE KIT W/BRASS
Long - 1/2 + Full Deck HANDLE
L
Extension
C NO HARDWARE KIT
Notes:
P/N Example shown represents a weld-in system, 300 A, 38 kV, vertical (cover-mounted), full deck extension, three-phase, w/o indicator plate,
with standard brass handle hardware kit, 6:00/9:00 positions. (Other handle position options available upon request for 9:00/12:00, 12:00/3:00,
and 3:00/6:00 positions. Consult your Cooper Power Systems sales representative for details.)
* Indicator plate not available for weld-in system, only available for ring mount systems.
**Cover mounted Weld-In switches have all externally located parts made of stainless steel or brass.
B100-95023 73
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Externally Operated Series 800-71 Externally operated switch The Dual Voltage switch shall Single-Phase 6 Terminals on Front Deck
Multiple Switches, 150 A, 150 kV S800-71-1 used to connect the primary be externally operated, snap
BIL, Single-Phase transformer winding either action switch with Cap wrench Bolt Tabs 2237434C01M
in series for higher winding or Padlockable Lever Handle
ratio, or parallel for lower ratio. operating systems. 16-14 AWG Terminals 2237434C02M
Allows one transformer to be 12-10 AWG Terminals 2237434C03M
stocked for use on any of two
or three distribution systems. 8 AWG Terminals 2237434C04M
6 AWG Terminals 2237434C05M
Bolt Tab with 1/4 - 20 Threaded Stud 2237434C16M
Single-Phase 8 Terminals on Front Deck
Bolt Tabs 2237434C51M
16-14 AWG Terminals 2237434C52M
12-10 AWG Terminals 2237434C53M
8 AWG Terminals 2237434C54M
6 AWG Terminals 2237434C55M
Bolt Tab with 1/4 - 20 Threaded Stud 2237434C66M
Single-Phase 6 Terminals Front Deck, 4-Terminal Back
Deck
Bolt Tabs 2237435C01M
16-14 AWG Terminals 2237435C02M
12-10 AWG Terminals 2237435C03M
8 AWG Terminals 2237435C04M
6 AWG Terminals 2237435C05M
Bolt Tab with 1/4 - 20 Threaded Stud 2237435C06M
Single-Phase 8 Terminals Front Deck, 4 Terminals Back
Deck
Bolt Tabs 2237435C51M
16-14 AWG Terminals 2237435C52M
12-10 AWG Terminals 2237435C53M
8 AWG Terminals 2237435C54M
6 AWG Terminals 2237435C55M
Bolt Tab with 1/4 - 20 Threaded Stud 2237435C56M
Single-Phase Double Back Plate, 8 Terminals
Bolt Tabs 2237492C01M
16-14 AWG Terminals 2237492C02M
12-10 AWG Terminals 2237492C03M
8 AWG Terminals 2237492C04M
B100-95023 75
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Externally Operated Series 800-71 8 Terminals on Front Deck
Multiple Switches, 150 A, 150 kV S800-71-1 Bolt Tabs 2237438C51M
BIL, Single-Phase
(continued) 16-14 AWG Terminals 2237438C52M
12-10 AWG Terminals 2237438C53M
8 AWG Terminals 2237438C54M
6 AWG Terminals 2237438C55M
Single-Phase Special Switch With 8 Terminals on Front and
Back Deck
Bolt Tabs 2238011C01M
16-14 AWG Terminals 2238011C02M
12-10 AWG Terminals 2238011C03M
8 AWG Terminals 2238011C04M
6 AWG Terminals 2238011C05M
Single-Phase Switch without Back Deck 6 Terminals on
Front Deck
Bolt Tabs 2237262C01M
16-14 AWG Terminals 2237262C02M
12-10 AWG Terminals 2237262C03M
8 AWG Terminals 2237262C04M
6 AWG Terminals 2237262C05M
Bolt Tab with 1/4 - 20 Threaded Stud 2237262C16M
Single-Phase Switch with 8 Terminals on Front Deck
Bolt Tabs 2237262C51M
16-14 AWG Terminals 2237262C52M
12-10 AWG Terminals 2237262C53M
8 AWG Terminals 2237262C54M
6 AWG Terminals 2237262C55M
Bolt Tab with 1/4 - 20 Threaded Stud 2237262C66M
Single-Phase Switch with 4 Terminal Back Deck 6 Terminals on
Front Deck
Bolt Tab 2237264C01M
16-14 AWG Terminals 2237264C02M
12-10 AWG Terminals 2237264C03M
8 AWG Terminals 2237264C04M
6 AWG Terminals 2237264C05M
Bolt Tab With 1/4 - 20 Threaded Stud 2237264C16M
Single-Phase 8 Terminals on Front Deck
Bolt Tabs 2237264C51M
16-14 AWG Terminals 2237264C52M
12-10 AWG Terminals 2237264C53M
B100-95023 77
1
3
2
8
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Externally Operated Series 800-72 Externally operated switch The Dual Voltage switch Two-Phase Switch w/6 Terminals on Front Deck,
Multiple Switches, 150 A, 150 kV S800-72-1 used to connect the primary shall be externally operated, (2 Main Decks)
BIL, Two- and Three-Phase transformer winding either snap action switch with Bolt Tabs 2237266C01M
in series for higher winding Padlockable Hotstick or T
ratio, or parallel for lower ratio. Handle operating systems. 16-14 AWG Terminals 2237266C02M
Allows one transformer to be Silver plated contacts option if 12-10 AWG Terminals 2237266C03M
stocked for use on any of two desired.
or three distribution systems. 8 AWG Terminals 2237266C04M
6 AWG Terminals 2237266C05M
Two-Phase Switch w/8 Terminals on Front Deck
(2 Main Decks)
Bolt Tabs 2237266C51M
16-14 AWG Terminals 2237266C52M
12-10 AWG Terminals 2237266C53M
8 AWG Terminals 2237266C54M
6 AWG Terminals 2237266C55M
Three-Phase Switch with 4 Terminal Back Deck
6 Terminals on Front Deck
Bolt Tabs 2237914C01M
16-14 AWG Terminals 2237914C02M
12-10 AWG Terminals 2237914C03M
8 AWG Terminals 2237914C04M
6 AWG Terminals 2237914C05M
Bolt Tab with 1/4 - 20 Threaded Stud 2237914C16M
Special Three-Phase Switch with 6 Terminals on All Deck
Bolt Tabs 2237560C01M
Bolt Tab with 1/4 - 20 Threaded Stud 2237560C06M
Special Three-Phase Switch with
8 Terminals on Front Deck
Front Deck 2237560C51M
Bolt Tab with 1/4 - 20 Threaded Stud 2237560C56M
Two-Phase Special Switch 8 Terminals on Front Deck (Tri-Voltage
Switch)
Bolt Tabs 2237510C01M
Three-Phase Switch without Back Deck
6 Terminals on Front Decks
Bolt Tabs 2237265C01M
16-14 AWG Terminals 2237265C02M
12-10 AWG Terminals 2237265C03M
8 AWG Terminals 2237265C04M
6 AWG Terminals 2237265C05M
Bolt Tab With 1/4 - 20 Threaded Stud 2237265C16M
Three-Phase Switch without Back Deck
8 Terminals on Front Decks
Bolt Tabs 2237265C51M
3
2
8
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Externally Operated Series 800-72 16-14 AWG Terminals 2237265C52M
Multiple Switches, 150 A, 150 kV S800-72-1
BIL, Two- and Three-Phase 12-10 AWG Terminals 2237265C53M
(continued) 8 AWG Terminals 2237265C54M
6 AWG Terminals 2237265C55M
Bolt Tab with 1/4 - 20 Threaded Stud 2237265C66M
Three-Phase Switch 4 Terminal Back Deck, 6 Terminals on
Front Deck
Bolt Tabs 2237403B01M
16-14 AWG Terminals 2237403B02M
12-10 AWG Terminals 2237403B03M
8 AWG Terminals 2237403B04M
6 AWG Terminals 2237403B05M
Bolt Tab with 1/4 - 20 Threaded Stud 2237403B16M
Three-Phase Switch 8 Terminal Double Back Deck,
6 Terminals on Front Deck
Bolt Tabs 2237403B06M
16-14 AWG Terminals 2237403B07M
12-10 AWG Terminals 2237403B08M
8 AWG Terminals 2237403B09M
6 AWG Terminals 2237403B10M
Bolt Tab with 1/4 - 20 Threaded Stud 2237403B11M
Three-Phase Switch 4 Terminal Back Deck, 8 Terminals on
Front Deck
Bolt Tabs 2237403B51M
16-14 AWG Terminals 2237403B52M
12-10 AWG Terminals 2237403B53M
8 AWG Terminals 2237403B54M
6 AWG Terminals 2237403B55M
Bolt Tab with 1/4 - 20 Threaded Stud 2237403B66M
Three-Phase Switch 8 Terminal Double Back Deck,
8 Terminals on Front Deck
Bolt Tabs 2237403B56M
16-14 AWG Terminals 2237403B57M
12-10 AWG Terminals 2237403B58M
8 AWG Terminals 2237403B59M
6 AWG Terminals 2237403B60M
6 AWG Terminals 2237403B60M
Bolt Tab with 1/4 - 20 Threaded Stud 2237403B61M
B100-95023 79
Separable Connectors
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Externally Operated Series 800-72 Three-Phase Special Switch 8 Terminals on Front Deck,
Multiple Switches, 150 A, 150 kV S800-72-1 5 Terminals on Back Deck
BIL, Two- and Three-Phase
(continued) Bolt Tabs 2237908C01M
Three-Phase Special Switch 6 Terminals on Front Deck,
No Terminals on Back Deck For Support Only
Bolt Tabs 2237586C01M
Three-Phase Switch without Back Deck
6 Terminals on Front Decks (Cover Mount Switch)
Bolt Tabs 2237467C01M
16-14 AWG Terminals 2237467C02M
12-10 AWG Terminals 2237467C03M
Three-Phase Switch without Back Deck 8 Terminals on
Front Decks
Bolt Tabs 2237467C51M
Three-Phase Switch with 6 Terminal Back Deck
6 Terminals on Front Deck (Tri-Voltage Switch)
Bolt Tabs 2237404B01M
16-14 AWG Terminals 2237404B02M
12-10 AWG Terminals 2237404B03M
8 AWG Terminals 2237404B04M
6 AWG Terminals 2237404B05M
Bolt Tab with 1/4 - 20 Threaded Stud 2237404B06M
Three-Phase Switch with 6 Terminal Back Deck
8 Terminals on Front Deck (Tri-Voltage Switch)
Bolt Tabs 2237404B51M
16-14 AWG Terminals 2237404B52M
12-10 AWG Terminals 2237404B53M
8 AWG Terminals 2237404B54M
6 AWG Terminals 2237404B55M
Bolt Tab with 1/4 - 20 Threaded Stud 2237404B56M
Externally Operated Series 800-75 Externally operated switch The Dual-Voltage switch shall Single-Phase, Dual-Voltage with 6 2201977B01M
Multiple Switches, 300 A, 150 kV S800-75-1 used to connect the primary be externally operated, snap Terminals
BIL transformer winding either action switch with Padlockable Two-Phase, Dual-Voltage with 6 2201977B17M
in series for higher winding Lever Handle, or Padlockable Terminals on each Deck
ratio, or parallel for lower ratio. Hotstick operating systems.
Allows one transformer to be Three-Phase, Dual-Voltage with 6 2201977B02M
stocked for use on any of two Terminals on each Deck
or three distribution systems.
Three-Phase, Dual-Voltage with 8 2201977B05M
Terminals on each Deck
Single-Phase, Dual-Voltage with 4 2201977B04M
Terminal Back Switch
80 OEM Product Guide November 2010 Supersedes 95023, 10/01
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
LOADBREAK CONNECTORS
Loadbreak Elbow Connector 500-10-7 Fully-shielded/insulated plug-in The Loadbreak elbow shall 200 A, 15 kV
500-10-7C termination for connecting conform to IEEE Std 386
(Canadian) shielded, insulated, deadfront standard Separable Insulated Elbow without Test Point, with LE215- - -
S500-10-7 connection of underground Connectors for Power CopperTop Connector, Bulk Pack
S500-10-8 (URG) cable to transformers, Distribution Systems Above Elbow without Test Point, with LE215- - -X
switching cabinets and 600 V. Bimetallic (Coppertop CopperTop Connector, Individual Box
junctions equipped with Connectors). Kit
loadbreak bushings. Provides
capability for continuous Elbow with Test Point, with CopperTop LE215- - -T
current rating and load per unit Connector, Bulk Pack
and breaking to 200 A, 15 kV.
Elbow with Test Point, with CopperTop LE215- - -TX
NOTE: To add optional Jacket Connector, Individual Box Kit
Seal Option, insert a J after Elbow without Test Point, with LE215CCA- -
LE, ie: LEJ215. CopperTop Connector, Bulk Pack, with
5 kV Cable Adapter
Elbow without Test Point, with LE215CCA- -X
CopperTop Connector, Individual Box
Kit, with 5 kV Cable Adapter
Elbow with Test Point, with CopperTop LE215CCA- -T
Connector, Bulk Pack, with 5 kV Cable
Adapter
Elbow with Test Point, with CopperTop LE215CCA- -TX
Connector, Individual Box Kit, with 5 kV
Cable Adapter
Elbow without Test Point, with LE215CCB- -
CopperTop Connector, Bulk Pack, with
5 kV Cable Adapter
Elbow without Test Point, with LE215CCB- -X
CopperTop Connector, Individual Box
Kit, with 5 kV Cable Adapter
Elbow with Test Point, with CopperTop LE215CCB- -T
Connector, Bulk Pack, with 5 kV Cable
Adapter
Elbow with Test Point, with CopperTop LE215CCB- -TX
Connector, Individual Box Kit, with 5 kV
Cable Adapter
Elbow without Test Point, without LE215-00
CopperTop Connector, Bulk Pack
Elbow without Test Point, without LE215-00X
CopperTop Connector, Individual Box
Kit
Elbow with Test Point, without LE215-00T
CopperTop Connector, Bulk Pack
Elbow with Test Point, without LE215-00TX
CopperTop Connector, Individual Box
Kit
B100-95023 81
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Expanded Range Loadbreak 500-28-7 Fully-shielded/insulated The Loadbreak elbow shall 200 A, 25 kV
Elbow Connector S500-10-1 plug-in termination for conform to IEEE Std 386
500-28-7C connecting shielded, insulated, standard Separable Insulated Elbow without Test Point, with LE225- - -
(28 kV deadfront conn of URG cable Connectors for Power CopperTop Connector, Bulk Pack
Canadian) to transformers, switching Distribution Systems Above
cabinets and junctions 600 V. Bimetallic (Coppertop Elbow without Test Point, with LE225- - -X
equipped w/loadbreak Connectors). CopperTop Connector, Individual Box
bushings. Provides capability Kit
for continuous current rating Elbow with Test Point, with CopperTop LE225- - -T
and load per unit and breaking Connector, Bulk Pack
to 200 A, 25 kV.
Elbow with Test Point, with CopperTop LE225- - -TX
NOTE: To add optional Jacket Connector, Individual Box Kit
Seal Option, insert a J after
LE, ie: LEJ225. Elbow without Test Point, without LE225-00
CopperTop Connector, Bulk Pack
Elbow without Test Point, without LE225-00X
CopperTop Connector, Individual Box
Kit
Elbow with Test Point, without LE225-00T
CopperTop Connector, Bulk Pack
Elbow with Test Point, without LE225-00TX
CopperTop Connector, Individual Box
Kit
Three-Phase Loadbreak Elbow 500-41 Fully-shielded/insulated The Loadbreak elbow shall 200 A, 35 kV
Connector S500-41-1 plug-in termination for three- conform to IEEE Std 386
phase shielded, insulated, standard Separable Insulated Elbow without Test Point, with LE235- - -
deadfront conn. of URG cable Connectors for Power CopperTop Connector, Bulk Pack
to transformers, switching Distribution Systems Above
cabinets and junctions 600 V. Bimetallic (Coppertop Elbow without Test Point, with LE235- - -X
equipped w/loadbreak Connectors). CopperTop Connector, Individual Box
bushings. Provides capability Kit
for continuous current rating Elbow with Test Point, with CopperTop LE235- - -T
and load per unit and breaking Connector, Bulk Pack
to 200 A, 35 kV.
Elbow with Test Point, with CopperTop LE235- - -TX
Connector, Individual Box Kit
Elbow without Test Point, without LE235-00
CopperTop Connector, Bulk Pack
Elbow without Test Point, without LE235-00X
CopperTop Connector, Individual Box
Kit
Elbow with Test Point, without LE235-00T
CopperTop Connector, Bulk Pack
B100-95023 83
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Rotatable Feedthru Insert 500-13 Used to provide dual bushings The Rotatable Feedthru must 200 A, 15 kV LFI215
S500-13-1 from a single apparatus conform to IEEE Std 386
bushing well. It allows the standard. The current carrying
conversion of a radial feed path will be all copper/copper
transformer to feedthru alloy. Shall have a torque
transformer. In addition it limiting feature between 7-14
provides area for installation ft-lbs to eliminate bushing
of MOVE Arresters for cable well stud breakage. Must be
protection. capable of rotating clockwise
continuously without loosening
the current interchange.
Rotatable Feedthru Insert 500-30 Used to provide dual bushings The Rotatable Feedthru must 200 A, 25 kV LFI225
500-30C from a single apparatus conform to IEEE Std 386
(28 kV bushing well. It allows the standard. The current carrying
Canadian) conversion of a radial feed path will be all copper/copper
S500-13-1 transformer to feedthru alloy. Shall have a torque
transformer. In addition it limiting feature between 7-14
provides area for installation ft-lbs to eliminate bushing
of MOVE Arresters for cable well stud breakage. Must be
protection. capable of rotating clockwise
continuously without loosening
the current interchange.
Loadbreak Portable Feedthru 500-14 Used in pad-mounted The Portable Feedthru must Horizontal Feedthru LPF215H
200 A, 15 kV S500-14-1 equipment, underground be able to be used with 15
vaults, and other apparatus to kV Class loadbreak elbows Vertical Feedthru LPF215V
bypass transformers, to test and other accessories and Universal (Horizontal/Vertical Combina- LPF215U
and ground circuits, and to meet the requirements of tion)
provide open point deadfront IEEE Std 386 standard. The
lightning arrester protection. Portable Feedthru shall also
be fully shielded, submersible,
separable connection for
loadbreak operation.
Loadbreak Portable Feedthru 500-31 Used in pad-mounted The Portable Feedthru must Horizontal Feedthru LPF225H
200 A, 25 kV 500-31C equipment, underground be able to be used with 25
(28 kV vaults, and other apparatus to kV Class loadbreak elbows Vertical Feedthru LPF225V
Canadian) bypass transformers, to test and other accessories and Universal (Horizontal/Vertical LPF225U
S500-14-1 and ground circuits, and to meet the requirements of Combination)
provide open point deadfront IEEE Std 386 standard. The
lightning arrester protection. Portable Feedthru shall also
be fully shielded, submersible,
separable connection for
leadbreak operation.
Three-Phase Loadbread Portable 500-49 Used in pad-mounted The Portable Feedthru must Horizontal Feedthru LPF235H
Feedthru S500-14-1 equipment, underground be able to be used with large
200 A, 35 kV vaults, and other apparatus to 35 kV Class loadbreak elbows Vertical Feedthru LPF235V
bypass transformers, to test and other accessories and
and ground circuits, and to meet the requirements of
provide open point deadfront IEEE Std 386 standard. The
lightning arrester protection. Portable Feedthru shall also
be fully shielded, submersible,
separable connection for
leadbreak operation.
B100-95023 85
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Three-Phase Loadbreak Junction 500-51 Used in pad-mounted The junction shall provide 200 A 35 kV Class Three-Phase Loadbreak Junction
apparatus, underground two, three or four 21.1/36.6
vaults, and other apparatus kV loadbreak interfaces that 2 Interfaces Junction with Stainless LJ235C2B
to sectionalize, establish are internally bused together Steel Bracket
loops, taps and splices, and meet all requirements of
and to facilitate apparatus IEEE Std 386 standard - 3 Interfaces Junction with Stainless LJ235C3B
changeouts. Separable Insulated Connector Steel Bracket
Systems. The junction shall 4 Interfaces Junction with Stainless LJ235C4B
also have a solid current path Steel Bracket
of all copper.
2 Interfaces Junction with U-Straps LJ235C2U
3 Interfaces Junction with U-Straps LJ235C3U
4 Interfaces Junction with U-Straps LJ235C4U
2 Interfaces Junction Only LJ235C2
3 Interfaces Junction Only LJ235C3
4 Interfaces Junction Only LJ235C4
200 A 15/25 kV Class Bushing 500-38 Provides an insulated, fully The Bushing Well Insulated Insulated Bushing Well Plug IBWP225
Well Insulated Plug 500-38C shielded, submersible cover Plug shall meet the full
(28 kV Ca- for unused 15 and 25 kV Class requirements of IEEE Std
nadian) bushing well in deadfront 386 standard - Separable,
equipment Insulated Connector Systems.
It shall also be molded of
high quality EPDM insulation
and have a molded semi-
conductive EPDM shield. The
plug will also have a molded
ground tab on the shield to
allow attachment of ground
wire to ensure deadfront
construction.
200 A 15 kV Class Loadbreak 500-21 Designed to electrically The cap shall provide Loadbreak Protective Cap with Drain LPC215
Protective Cap with Insulated S500-21-1 insulate and mechanically seal permanent or temporary Wire, Bulk Pack LBC215X
Cuff loadbreak bushing interfaces. installation on bushings,
When mated to a loadbreak junctions or feedthru devices Loadbreak Protective Cap with Drain LPC215X
product and the drain wire is that meet the requirements of Wire, Individual Box Kit
attached to ground, it provides IEEE Std 386 standard.
a fully shielded, submersible
insulating cover for energized
bushings.
200 A 25 kV Class Loadbreak 500-39 Designed to electrically The cap shall provide Loadbreak Protective Cap, with Drain LPC225
Protective Cap with Insulated Cuff S500-21-1 insulate and mechanically seal permanent or temporary Wire, with Insulated Cuff, Bulk Pack LPC225X
loadbreak bushing interfaces. installation on bushings,
When mated to a loadbreak junctions or feedthru devices Loadbreak Protective Cap, with Drain LPC225X
product and the drain wire is that meet the requirements of Wire, with Insulated Cuff, Individual Box
attached to ground, it provides IEEE Std 386 standard. Kit
a fully shielded, submersible
insulating cover for energized
bushings.
Insulated Standoff Bushing 500-40 Isolates and sectionalizes The Insulated Standoff Standoff Bushing with Standard Bracket ISB225
200 A, 25 kV Class 500-40C energized cable in pad- Bushing shall be designed
(28 kV mounted cabinets, to install in the parking stand Standoff Bushing with Stainless Steel ISB225S
Canadian) underground vaults, and other mounted on a transformer or Bracket
S500-22-1 apparatus other apparatus. It shall meet
the requirements of IEEE Std
386 standard. It shall also
provide a single loadbreak
interface made of high quality
insulating EPDM.
Insulated Standoff Bushing 500-66 Isolates and sectionalizes The insulated Standoff 200 A, 35kV (w/standard bracket) ISB235
S500-22-1 energized cable in pad- Bushing shall be designed
mounted cabinets, to install in the parking stand
underground vaults, and other mounted on a transformer or
apparatus other apparatus. It shall meet
the requirements of IEEE Std
386 standard. It shall also
provide a single loadbreak
interface made of high quality
insulating EPDM rubber.
15 kV Class Fused Loadbreak 500-110 Protects underground Fused elbow assembly shall 200 A, 15 kV LFEP215TFEC---AT
Elbow Connector S500-110-1 distribution systems provide full-range current- Note: For fuse to go
carrying capability, and limit 240-97
current and energy let-through
to the system when operating
due to a primary fault. Shall be
made of high quality insulating
EPDM rubber.
25 kV Class Fused Loadbreak 500-111 Protects underground Fused elbow assembly shall 200 A, 25 kV LFEP225TFEC---AT
Elbow Connector S500-110-1 distribution systems provide full-range current- Note: For fuse to go
carrying capability, and limit 240-97
current and energy let-through
to the system when operating
due to a primary fault. Shall be
made of high quality insulating
EPDM rubber.
B100-95023 87
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Deadbreak Connector, 200 A
Deadbreak Elbow Connector 550-10 Deadbreak Elbow Connector The Deadbreak Elbow 200 A, 15 & 25 kV DE225 - - T
S550-10-1 is a fully-shielded and insulated Connector shall be fully-
plug-in termination for shielded and insulated for use
connecting underground cable in deadbreak applications. The
to transformers, switching Deadbreak Elbow Connector
cabinets and junctions shall accept a wider range
equipped with deadbreak of cable diameter for a given
bushings. elbow size.
Deadbreak Straight Connector 550-12 Deadbreak Straight Connector The Deadbreak Straight 200 A, 15 & 25 kV DS225 - - T
S550-12-1 is a fully-shielded and insulated Connector shall be fully-
plug-in termination for shielded and insulated for use
connecting underground cable in deadbreak applications. The
to transformers, switching Deadbreak Straight Connector
cabinets and junctions shall accept a wider range
equipped with deadbreak of cable diameter for a given
bushings. elbow size. It shall also allow
mounting to be vertical,
horizontal, or any angle in
between.
DEADBREAK CONNECTORS
BOL-T Connector 600-30 Fully-shielded/insulated The Deadbreak connector 600 A 15 & 25 kV Bol-T Deadbreak Connector System
S600-10-2 separable termination for three- shall conform to the electrical, Without Test Point
phase shielded, insulated, mechanical and dimensional
deadfront connection of requirements of IEEE 386 Aluminum Bol-T Kit with Stud without Test BT625 - - - A1
URG cable to transformers, standard The connectors and Point
switching cabinets and associated cable components
junctions equipped w/ shall be interchangeable with Aluminum Bol-T Kit without Stud without Test BT625 - - - A2
deadbreak bushings. those currently available from Point
other major manufacturers. Copper Bol-T Kit with Stud without Test BT625 - - - C1
Point
Copper Bol-T Kit without Stud without Test BT625 - - - C2
Point
With Test Point
Aluminum Bol-T Kit with Stud with Test BT625 - - - A1T
Point
Aluminum Bol-T Kit without Stud with Test BT625 - - - A2T
Point
Copper Bol-T Kit with Stud with Test BT625 - - - C1T
Point
Copper Bol-T Kit without Stud with Test BT625 - - - C2T
Point
B100-95023 89
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
BT-TAP Connector System 600-15 15 kV BT-TAP Connector System (Copper)
(continued) S600-15-3 Without Test Point
BT-TAP Kit, 15 kV Copper, w/o stud, BTP615---C
w/o Test Point, w/o 200 A cap
BT-TAP Kit, 15 kV Copper, w/o stud, BTP615---CC
w/o Test Point, with 200 A cap
BT-TAP Kit, 15 kV Copper, with BTP615---CS
standard length stud, w/o Test Point,
w/o 200 A cap
BT-TAP Kit, 15 kV Copper, with BTP615---CSC
standard length stud, w/o Test Point,
with 200 A cap
BT-TAP Kit, 15 kV Copper, with BTP615---CL
extended length stud, w/o Test Point,
w/o 200 A cap
BT-TAP Kit, 15kV Copper, with extended BTP615---CLC
length stud, w/o Test Point with 200 A
cap
With Test Point
BT-TAP Kit, 15 kV Copper, w/o stud, BTP615---CT
with Test Point, w/o 200 A cap
BT-TAP Kit, 15 kV Copper, w/o stud, BTP615---CTC
with Test Point, with 200 A cap
BT-TAP Kit, 15 kV Copper, with BTP615---CST
standard length stud, with Test Point,
w/o 200 A cap
BT-TAP Kit, 15kV Copper, with standard BTP615---CSTC
length stud, with Test Point, with 200A
cap
BT-TAP Kit, 15kV Copper, with extended BTP615---CLT
length stud, with Test Point, w/o 200A
cap
BT-TAP Kit, 15kV Copper, with extended BTP615---CLTL
length stud, with Test Point, with 200A
cap
15kV BLRTP (Aluminum)
BLRTP, 15kV, Aluminum, w/o stud, BLRTP615A
individually bagged
BLRTP, 15kV, Aluminum, with standard BLRTP615AS
length stud, individually bagged
BLRTP, 15kV, Aluminum, with BLRTP615ASP
permanent standard length stud,
individually bagged
BLRTP, 15kV, Aluminum, with extended BLRTP615AL
length stud, individually bagged
BLRTP, 15kV, Aluminum, with BLRTP615ALP
permanent extended length stud,
individually bagged
BLRTP, 15kV, Aluminum, w/o stud, BLRTP615AX
individual cartons
BLRTP, 15kV, Aluminum, with standard BLRTP615ASX
length stud, individual cartons
B100-95023 91
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
BT-TAP Connector System 600-35 Used as a retrofit for existing The BT-TAP shall be fully 25 kV BT-TAP Connector System (Aluminum)
S600-35-1 BOL-T (or other bolted shielded, submersible and Without Test Point
systems that use unthreaded meet all the requirements of BT-TAP kit, 25 kV Aluminum, w/o stud, BTP625 - - - A
compression connectors) IEEE 386 standard. It shall w/o Test Point, w/o 200 A cap
systems with a 200 A be capable of providing a 200
loadbreak tap for testing, A Tap for testing, grounding, BT-TAP kit, 25 kV Aluminum, w/o stud, BTP625 - - - AC
grounding, or overvoltage or overvoltage protection. It w/o Test Point, with 200 A cap
protection. can be used for up to 900
A systems when used in BT-TAP kit, 25 kV Aluminum, with BTP625 - - - AS
conjunction with coppertop standard length stud, w/o Test Point,
compression connectors and w/o 200 A cap
copper bushing or junctions. BT-TAP kit, 25 kV Aluminum, with BTP625 - - - ASC
standard length stud, w/o Test Point,
with 200 A cap
BT-TAP kit, 25 kV Aluminum, with BTP625 - - - AL
extended length stud, w/o Test Point,
w/o 200 A cap
BT-TAP kit, 25 kV Aluminum, with BTP625 - - - ALC
extended length stud, w/o Test Point,
w/o 200 A cap
With Test Point
BT-TAP kit, 25 kV Aluminum, w/o stud, BTP625 - - - AT
with Test Point, w/o 200 A cap
BT-TAP kit, 25 kV Aluminum, w/o stud, BTP625 - - - ATC
with Test Point, with 200 A cap
BT-TAP kit, 25 kV Aluminum, with BTP625 - - - AST
standard length stud, with Test Point,
w/o 200 A cap
BT-TAP kit, 25 kV Aluminum, with BTP625 - - - ASTC
standard length stud, with Test Point,
with 200 A cap
BT-TAP kit, 25 kV Aluminum, with BTP625 - - - ALT
extended length stud, with Test Point,
w/o 200 A cap
BT-TAP kit, 25 kV Aluminum, with BTP625---ALTC
extended length stud, with Test Point,
with 200 A cap
25 kV BT-TAP Connector System (Copper)
Internal Rotating Nut Version
Without Test Point
BT-TAP kit, 25 kV Copper, w/o stud, w/o BTP625---C
Test Point, w/o 200 A cap
B100-95023 93
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
BT-TAP Connector System 600-55 Used as a retrofit for existing The BT-TAP shall be fully 35 kV BT-TAP Connector System (Aluminum)
S600-55-1 BOL-T (or other bolted shielded, submersible and Internal Rotating Nut Version Without Test Point
systems that use unthreaded meet all the requirements of
compression connectors) IEEE Std 386 standard. It BT-TAP kit, 35 kV Aluminum, with BTP635 - - - A
systems with a 200 A shall be capable of providing extended length stud, w/o Test Point,
loadbreak tap for testing, a 200 A. Tap for testing, w/o 200A cap
grounding, or overvoltage grounding, or overvoltage
protection. protection. It can be used BT-TAP kit, 35 kV Aluminum, with BTP635 - - - AC
for up to 900 A systems extended length stud, w/o Test Point,
when used in conjunction with 200A cap
with coppertop compression With Test Point
connectors and copper
bushing or junctions. BT-TAP kit, 35 kV Aluminum, with BTP635 - - - AT
extended length stud, with Test Point,
w/o 200A cap
BT-TAP kit, 35 kV Aluminum, with BTP635 - - - ATC
extended length stud, with Test Point,
with 200A cap
35 kV BT-TAP Connector System (Copper)
Internal Rotating Nut Version Without Test Point
BT-TAP kit, 35 kV Copper, with BTP635 - - - C
extended length stud, w/o Test Point,
w/o 200A cap
BT-TAP kit, 35 kV Copper, with BTP635 - - - CC
extended length stud, w/o Test Point,
with 200A cap
With Test Point
BT-TAP kit, 35 kV Copper, with BTP635 - - - CT
extended length stud, with Test Point,
w/o 200A cap
BT-TAP kit, 35 kV Copper, with BTP635 - - - CTC
extended length stud, with Test Point,
with 200A cap
35kV BLRTP (Copper)
Internal Rotating Nut Version
BLRTP, 35 kV, Copper, with extended BLRTP635
length stud, individual cartons.
B100-95023 95
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
PUSH-OP Connector 600-13 Fully-shielded/insulated The Deadbreak connector 600 A 15 kV PUSH-OP Connector System
S600-13-1 separable term. For three- shall conform to the electrical, Without Test Point
phase shielded, insulated, mechanical and dimensional
deadfront connection of requirements of IEEE Std Copper PUSH-OP Kit without Test Point POP615 - - -
URG cable to transformers, 386 standard. The 600A without 200 A Cap
switching cabinets and connector shall provide a
junctions equipped w/ totally threadless, DB, hotstick Copper PUSH-OP Kit without Test Point POP615 - - -C
deadbreak bushings. Includes operable connection system. with 200 A Cap
totally threadless 600 A A 200 A LB connector shall With Test Point
deadbreak interface and a also be provided
200A three-phase rated Copper PUSH-OP Kit with Test Point POP615 - - -T
loadbreak interface without 200 A Cap
Copper PUSH-OP Kit with Test Point POP615 - - -TC
with 200 A Cap
PUSH-OP Connector 600-33 Fully-shielded/insulated The Deadbreak connector 600 A 25 kV PUSH-OP Connector System
S600-13-1 separable term. For three- shall conform to the electrical, Without Test Point
phase shielded, insulated, mechanical and dimensional
deadfront connection of requirements of IEEE Std Copper PUSH-OP Kit without Test Point POP625 - - -
URG cable to transformers, 386 standard. The 600 without 200 A Cap
switching cabinets and A connector shall provide a
junctions equipped w/ totally threadless, DB, hotstick Copper PUSH-OP Kit without Test Point POP625 - - -C
deadbreak bushings. Includes operable connection system. with 200 A POSI-BREAK Cap
totally threadless 600 A A 200 A LB connector shall With Test Point
deadbreak interface and a 200 also be provided
A three-phase rated loadbreak Copper PUSH-OP Kit with Test Point POP625 - - -T
interface without 200 A Cap
Copper PUSH-OP Kit with Test Point POP625 - - -TC
with 200 A POSI-BREAK Cap
B100-95023 97
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Loadbreak Reducing Tap Plug 600-38 Converts a standard 600 The Bushing Adapter shall 600 A/200 A Bushing Adapter with LRTP DBA625
and Bushing Adapter for T-OP II S600-18-1 A deadbreak interface to a convert a standard 600 A (Stud-T Included)
Connector System standard 200 A loadbreak deadbreak interface to a
interface allowing for safe standard 200 A loadbreak Bushing Extender DBE625
testing and grounding. interface. It shall also meet all
the requirements for IEEE Std Bushing Extender with Aluminum Stud DBE625SA
386 standard and is 200 Bushing Extender with Copper Stud DBE625SC
A three-phase switching and
three-phase fault close rated. Loadbreak Reducing Tap Plug LRTP625
(Individually Boxed)
Loadbreak Reducing Tap Plug 600-59 Converts a standard 600 The Bushing Adapter shall 600 A/200 A Bushing Adapter with DBA635
and Bushing Adapter S600-59-1 A deadbreak interface to a convert a standard 600 A LRTP
S600-59-2 standard 200 A loadbreak deadbreak interface to a
interface allowing for safe standard 200 A loadbreak Bushing Extender DBE635
testing and grounding. interface. It shall also meet all
the requirements for IEEE Std Bushing Extender with Aluminum Stud DBE635SA
386 standard and is 200 (STUD635-A)
A three-phase switching and Bushing Extender with Copper Stud DBE635SC
three-phase fault close rated. (STUD635-C)
Load Reducing Tap Plug LRTP635
PUSH-OP Insulated Adapter Cap 600-19 Used to cap a 600 A PUSH-OP The PUSH-OP Insulated 600 A, 15 kV
S600-19-1 type bushing tap interface with Adapter Cap shall meet all
the 200 A loadbreak interface the requirements of IEEE Std 600 A/200 A Bushing Adapter for PDBA615
allowing for live testing and 386 standard and be able PUSH-OP without 200 A Cap
visible grounding. to cap a 600A PUSH-OP type
bushing tap interface. 600 A/200 A Bushing Adapter for PDBA615C
PUSH-OP with 200 A Cap
PUSH-OP Insulated Adapter Cap 600-39 Used to cap a 600 A PUSH-OP The PUSH-OP Insulated 600 A, 25 kV
S600-39-1 type bushing tap interface with Adapter Cap shall meet all
the 200 A loadbreak interface the requirements of IEEE Std 600 A/200 A Bushing Adapter for PDBA625
allowing for live testing and 386 standard and be able PUSH-OP without 200 A Cap
visible grounding. to cap a 600A PUSH-OP type
bushing tap interface. 600 A/200 A Bushing Adapter for PDBA625C
PUSH-OP with 200 A POSIBREAK
Cap
PUSH-OP Insulated Adapter Cap 600-58 Used to cap a 600 A PUSH-OP The PUSH-OP Insulated 600 A, 35 kV
S600-19-1 type bushing tap interface with Adapter Cap shall meet all
the 200 A loadbreak interface the requirements of IEEE Std 600 A/200 A Bushing Adapter for PDBA635
allowing for live testing and 386 standard and be able PUSH-OP without 200 A Cap
visible grounding. to cap a 600A PUSH-OP type
bushing tap interface. 600 A/200 A Bushing Adapter for PDBA635C
PUSH-OP with 200 A Cap
B100-95023 99
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Standoff Bushing 600-44 Isolated and sectionalizes The Insulated Standoff 15/25 kV, 600 A
600-44C energized cable in pad- Bushing shall be designed Aluminum Insulated Standoff Bushing ISB625A
(28 kV mounted cabinets, to install in the parking stand
Canadian) underground vaults, and other mounted on a transformer or Aluminum Insulated Standoff Bushing ISB625AST
S600-24-1 apparatus other apparatus. It shall meet with T-OP II Stud
the requirements of IEEE Std Aluminum Insulated Standoff Bushing
386 standard. It shall also ISB625ASA
with Aluminum Stud
provide a single deadbreak
interface made of high quality Aluminum Insulated Standoff Bushing ISB625ASU
insulating EPDM rubber. with U-OP Stud
Aluminum Insulated Standoff Bushing ISB625ASC
with Copper Stud
Copper Insulated Standoff Bushing ISB625C
Copper Insulated Standoff Bushing with ISB625CST
T-OP II Stud
Copper Insulated Standoff Bushing with ISB625CSU
U-OP Stud
Copper Insulated Standoff Bushing with ISB625CSC
Copper Stud
Copper Grounded Standoff Bushing GSB625C
Copper Grounded Standoff Bushing GSB625CST
with T-OP II Stud
Copper grounded Standoff Bushing with GSB625CSU
U-OP Stud
Copper Grounded Standoff Bushing GSB625CSC
with Copper Stud
Standoff Bushing 600-64 Isolated and sectionalizes The Insulated Standoff 35 kV, 600 A
S600-24-1 energized cable in pad- Bushing shall be designed Aluminum Insulated Standoff Bushing ISB635A
mounted cabinets, to install in the parking stand
underground vaults, and other mounted on a transformer or Aluminum Insulated Standoff Bushing ISB635AST
apparatus other apparatus. It shall meet with T-OP II Stud
the requirements of IEEE Std Aluminum Insulated Standoff Bushing
386 standard. It shall also ISB635ASA
with Aluminum Stud
provide a single deadbreak
interface made of high quality Aluminum Insulated Standoff Bushing ISB635ASC
insulating EPDM rubber. with Copper Stud
Copper Insulated Standoff Bushing ISB635C
Copper Insulated Standoff Bushing with ISB635CST
T-OP II Stud
Copper Insulated Standoff Bushing with ISB635CSC
Copper Stud
Aluminum Grounded Standoff Bushing GSB635A
Aluminum Grounded Standoff Bushing GSB635AST
with T-OP II Stud
Aluminum Grounded Standoff Bushing GSB635ASC
with Copper Stud
Aluminum Grounded Standoff Bushing GSB635ASA
with Aluminum Stud
B100-95023 101
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Deadbreak Junction 600-62 Used in pad-mounted The junction shall provide 35 kV, 600 A
S600-22-1 apparatus, underground two, three or four deadbreak
vaults, and other apparatus interfaces that are internally Aluminum 2-Way Junction Only DJ635A2
to sectionalize, establish bused together and meet DJ635A2U
loops, taps and splices, all requirements of IEEE Std Aluminum 2-Way Junction with U-
and to facilitate apparatus 386 standard - Separable Straps
changeouts. Insulated Connector Systems. Aluminum 2-Way Junction with Stain- DJ635A2B
The junction shall also have a less Steel Bracket
solid current path of all copper
or aluminum. Aluminum 3-Way Junction Only DJ635A3
Aluminum 3-Way Junction with U- DJ635A3U
Straps
Aluminum 3-Way Junction with Stain- DJ635A3B
less Steel Bracket
Aluminum 4-Way Junction Only DJ635A4
Aluminum 4-Way Junction with U- DJ635A4U
Straps
Aluminum 4-Way Junction with Stain- DJ635A4B
less Steel Bracket
Copper 2-Way Junction Only DJ635C2
Copper 2-Way Junction with U-Straps DJ635C2U
Copper 2-Way Junction with Stainless DJ635C2B
Steel Bracket
Copper 3-Way Junction Only DJ635C3
Copper 3-Way Junction with U-Straps DJ635C3U
Copper 3-Way Junction with Stainless DJ635C3B
Steel Bracket
Copper 4-Way Junction Only DJ635C4
Copper 4-Way Junction with U-Straps DJ635C4U
Copper 4-Way Junction with Stainless DJ635C4B
Steel Bracket
B100-95023 105
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Deadbreak Apparatus 650-10 Junction Bar, In-Line, Cu, 15/25 kV, (2) JBI25C2W3B
Connectors 200 A Wells, (3) 600 A Bushings, Std.
(continued) Brkt.
Junction Bar, In-Line, Cu, 15/25 kV, (2) JBI25C2W3BPS
200 A Wells, (3) 600 A Bushings, Parking
Stand Brkt.
Junction Bar, In-Line, Cu, 15/25 kV, JBI25C2W3BU
(2) 200 A Wells, (3) 600 A Bushings,
U-straps
Junction Bar, In-Line, Cu, 15/25 kV, (4) JBI25C4W1B
200 A Wells, (1) 600 A Bushing, Std.
Brkt.
Junction Bar, In-Line, Cu, 15/25 kV, (4) JBI25C4W1BPS
200 A Wells, (1) 600 A Bushing, Parking
Stand Brkt.
Junction Bar, In-Line, Cu, 15/25 kV, JBI25C4W1BU
(4) 200 A Wells, (1) 600 A Bushing,
U-straps
Junction Bar, In-Line, Cu, 15/25 kV, (1) JBI25C1B3W1B
600 A Bushing, (3) 200 A Wells, (1) 600
A Bushing, Std. Brkt.
Junction Bar, In-Line, Cu, 15/25 kV, JBI25C1B3W1BPS
(1) 600 A Bushing, (3) 200 A Wells, (1)
600A Bushing, P.S. Brkt.
Junction Bar, In-Line, Cu, 15/25 kV, (1) JBI25C1B3W1BU
600 A Bushing, (3) 200 A Wells, (1) 600
A Bushing, U-straps
Junction Bar, In-Line, Cu, 15/25 kV, (3) JBI25C3W3B
200 A Wells, (3) 600 A Bushings, Std.
Brkt.
Junction Bar, In-Line, Cu, 15/25 kV, (3) JBI25C3W3BPS
200 A Wells, (3) 600 A Bushings, Park-
ing Stand Brkt
Junction Bar, In-Line, Cu, 15/25 kV, JBI25C3W3BU
(3) 200 A Wells, (3) 600 A Bushings,
U-straps
Junction Bar, In-Line, Cu, 15/25 kV, (1) JBI25C1B4W1B
600 A Bushing, (4) 200 A Wells, (1) 600
A Bushing, Std. Brkt.
Junction Bar, In-Line, Cu, 15/25 kV, (1) JBI25C1B4W1BPS
600 A Bushing, (4) 200 A Wells, (1) 600
A Bushing, P.S. Brkt.
Junction Bar, In-Line, Cu, 15/25 kV, (1) JBI25C1B4W1BU
600 A Bushing, (4) 200 A Wells, (1) 600
A Bushing, U-straps
B100-95023 107
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Deadbreak Apparatus 650-10 15/25 kV CLASS Stacked Junctions
Connectors
(continued) Junction Bar, Stacked, Cu, 15/25 kV, (2) JBS25C2W3W
200A Wells, (3) 200 A Wells, Std. Brkt.
B100-95023 109
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Deadbreak Apparatus 650-10 Junction Bar, In-Line, Cu, 35 kV, (4) 600 JBI35C4B
Connectors A Bushings, Std. Brkt.
(continued) Junction Bar, In-Line, Cu, 35 kV, (4) 600 JBI35C4BPS
A Bushings, Parking Stand Brkt.
Junction Bar, In-Line, Cu, 35 kV, (4) 600 JBI35C4BU
A Bushings, U-straps
Junction Bar, In-Line, Cu, 35 kV, (5) 600 JBI35C5B
A Bushings, Std. Brkt.
Junction Bar, In-Line, Cu, 35 kV, (5) 600 JBI35C5BPS
A Bushings, Parking Stand Brkt.
Junction Bar, In-Line, Cu, 35 kV, (5) 600 JBI35C5BU
A Bushings, U-straps
Junction Bar, In-Line, Cu, 35 kV, (6) 600 JBI35C6B
A Bushings, Std. Brkt.
Junction Bar, In-Line, Cu, 35 kV, (6) 600 JBI35C6BPS
A Bushings, Parking Stand Brkt.
Junction Bar, In-Line, Cu, 35 kV, (6) 600 JBI35C6BU
A Bushings, U-straps
Junction Bar, In-Line, Cu, 35 kV, (1) 200 JBI35C1W2B
A Well, (2) 600 A Bushings, Std. Brkt.
Junction Bar, In-Line, Cu, 35 kV, (1) 200 JBI35C1W2BPS
A Well, (2) 600 A Bushings, Parking
Stand Brkt.
Junction Bar, In-Line, Cu, 35 kV, (1) 200 JBI35C1W2BU
A Well, (2) 600 A Bushings, U-straps
Junction Bar, In-Line, Cu, 35 kV, (1) 600 JBI35C1B1W1B
A Bushing, (1) 200 A Well, (1) 600 A
Bushing, Std. Brkt.
Junction Bar, In-Line, Cu, 35 kV, (1) 600 JBI35C1B1W1BPS
A Bushing, (1) 200 A Well, (1) 600 A
Bushing, P.S. Brkt.
Junction Bar, In-Line, Cu, 35 kV, (1) 600 A JBI35C1B1W1BU
Bushing, (1) 200 A Well, (1) 600 A Bushing,
U-straps
Junction Bar, In-Line, Cu, 35 kV, (2) 200 JBI35C2W1B
A Wells, (1) 600 A Bushing, Std. Brkt.
Junction Bar, In-Line, Cu, 35 kV, (2) 200 JBI35C2W1BPS
A Wells, (1) 600 A Bushing, Parking
Stand Brkt.
Junction Bar, In-Line, Cu, 35 kV, (2) 200 JBI35C2W1BU
A Wells, (1) 600 A Bushing, U-straps
B100-95023 111
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Deadbreak Apparatus 650-10 Junction Bar, In-Line, Cu, 35 kV, (4) 200 JBI35C4W1B
Connectors A Wells, (1) 600 A Bushing, Std. Brkt.
(continued) Junction Bar, In-Line, Cu, 35 kV, (4) 200 JBI35C4W1BPS
A Wells, (1) 600 A Bushing, Parking
Stand Brkt.
Junction Bar, In-Line, Cu, 35 kV, (4) 200 JBI35C4W1BU
A Wells, (1) 600 A Bushing, U-straps
Junction Bar, In-Line, Cu, 35 kV, (1) 600 JBI35C1B3W1B
A Bushing, (3) 200 A Wells, (1) 600 A
Bushing, Std. Brkt.
Junction Bar, In-Line, Cu, 35 kV, (1) 600 JBI35C1B3W1BPS
A Bushing, (3) 200 A Wells, (1) 600A
Bushing, P.S. Brkt.
Junction Bar, In-Line, Cu, 35 kV, (1) 600 JBI35C1B3W1BU
A Bushing, (3) 200 A Wells, (1) 600 A
Bushing, U-straps
Junction Bar, In-Line, Cu, 35 kV, (3) 200 JBI35C3W3B
A Wells, (3) 600 A Bushings, Std. Brkt.
Junction Bar, In-Line, Cu, 35 kV, (3) 200 JBI35C3W3BPS
A Wells, (3) 600 A Bushings, Parking
Stand Brkt
Junction Bar, In-Line, Cu, 35 kV, (3) 200 JBI35C3W3BU
A Wells, (3) 600 A Bushings, U-straps
Junction Bar, In-Line, Cu, 35 kV, (1) 600 JBI35C1B4W1B
A Bushing, (4) 200 A Wells, (1) 600 A
Bushing, Std. Brkt.
Junction Bar, In-Line, Cu, 35 kV, (1) 600 JBI35C1B4W1BPS
A Bushing, (4) 200 A Wells, (1) 600 A
Bushing, P.S. Brkt.
Junction Bar, In-Line, Cu, 35 kV, (1) 600 JBI35C1B4W1BU
A Bushing, (4) 200 A Wells, (1) 600 A
Bushing, U-straps
35 kV CLASS, L Splices
Junction Bar, L-Splice, Cu, 35 kV, (2) JBL35C2W1W
200 A Wells, (1) 200 A Well, Std. Brkt.
Junction Bar, L-Splice, Cu, 35 kV, (2) JBL35C2W1WPS
200 A Wells, (1) 200 A Well, Parking
Stand Brkt.
Junction Bar, L-Splice, Cu, 35 kV, (2) jbl35c2w1wu
200 A Wells, (1) 200 A Well, U-straps
Junction Bar, L-Splice, Cu, 35 kV, (4) JBL35C4W2B
200 A Wells, (2) 600 A Bushings, Std.
Brkt.
Junction Bar, L-Splice, Cu, 35 kV, (4) JBL35C4W2BPS
200 A Wells, (2) 600 A Bushings, Parking
Stand Brkt.
Junction Bar, L-Splice, Cu, 35 kV, (4) JBL35C4W2BU
200 A Wells, (2) 600 A Bushings, U-
straps
112 OEM Product Guide November 2010 Supersedes 95023, 10/01
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Deadbreak Apparatus 650-10 35 kV CLASS, Y Splices Three-PHASE
Connectors
(continued) Junction Bar, Y-Splice, Cu, 3ph, 1 pc., JBY3351C3W
35 kV, (3) 200 A Wells Per Phase, Std.
Brkt.
35 kV, Y Splices
Junction Bar, Y-Splice, Cu, 3ph, 35 kV, JBY335C1W2B
(1) 200 A Well, (2) 600 A Bushings Per
Phase, Std. Brkt.
B100-95023 113
Catalog Recommended
Product Typical Application Description Catalog Numbers
Section Spec Wording
Deadbreak Apparatus Connec- 650-10 Junction Bar, Stacked, Cu, 35 kV, (2) JBS35C2W3B
tors 200 A Wells, (3) 600 A Bushings, Std.
(continued) Brkt.
Junction Bar, Stacked, Cu, 35 kV, (2) JBS35C2W3BPS
200 A Wells, (3) 600 A Bushings, Parking
Stand Brkt.
Junction Bar, Stacked, Cu, 35 kV, (2) JBS35C2B1W2B
600 A Bushings, (1) 200 A Well, (2) 600
A Bushings, Std. Brkt.
Junction Bar, Stacked, Cu, 35 kV, (2) JBS35C2B1W2BPS
600 A Bushings, (1) 200 A Well, (2) 600
A Bushings, P.S. Brkt.
Junction Bar, Stacked, Cu, 35 kV, (3) JBS35C3W3W
200 A Wells, (3) 200 A Wells, Std. Brkt.
B100-95023 115
Cooper Power Systems
2300 Badger Drive
Waukesha, WI 53188
P: 1.877.CPS.INFO
www.cooperpower.com
email: info@cooperpowercentral.com