Section 5
Contents
2 Assemblies in CP 1000........................................................................................... 2
1 Assemblies in CURIX 60
1
2
1
2 3
3
4 5 6
6
946212aaa
7 13 8 9 10 11 12
Fig. 5 - 1
2 Assemblies in CP 1000
1
2
1
2 3
3
4
5
4
5 6
6
7 13 8 9 10 11 12 14
946212aab
Fig. 5 - 2
3 Functional procedure
As long as the machine is switched on, the upper dryer fan runs continuously
to avoid condensation on the feed table.
Fig. 5 - 4
946202KM.CDR
Fig. 5 - 5
Dryer steps CURIX 60, Type 9462/106 and CP 1000 Type 9462/206/846
The IR-heaters are triggered with the following voltages:
1 2 3 4 5 6
50 V 70 V 85 V 100 V 125 V 145 V
Dryer steps CURIX 60, Type 9462/105/155/165 and CP 1000 Type 9462/205/285/845
Due to phase-control the IR-heaters reach the following percentage of their possible
maximum capacity:
1 2 3 4 5 6
10 % 20 % 30 % 40 % 50 % 60 %
The dryer step is to be adjusted according to the film. When dried properly,
the film is neither moist nor sticky when it leaves the machine.
Fig. 5 - 6
Fig. 5 - 7
946205LM.CDR
Fig. 5 - 8
IMPORTANT: While the film transport is running, the processor should not be
switched off apart from in an emergency.