Sunteți pe pagina 1din 2

Column Base Plate - Transfer Tower TT-100

Type: 1 Column Size: H 250x250


Load X-Axis Y-Axis Z-Axis
Ref: Design of Structural Connections, 4th Ed, by TJ Hogan Node Case Force Force Force
kN kN kN
Actions (output from SpaceGass) 87 304 21.598 108.284 -4.091
A) Compression & Shear 127 105 -19.918 66.587 5.399
Fx = 4.406 kN Shear 1 304 -0.344 419.632 4.406
Fy = 419.63 kN Compression 35 101 -0.988 -285.561 -9.207
Mz = 0 kNm Moment 125 304 -4.102 146.798 23.465
B) Tension & Shear 149 104 -2.836 117.391 -56.824
Fx = 9.207 kN Shear 87 203 3.785 95.341 -3.026
Fy = -285.6 kN Tension 31 104 -0.459 149.49 5.562
Mz = 0 kNm Moment 170 104 -2.09 105.753 -37.465
96 401 -1.638 -29.418 -6.641
Base plate size Concrete grade 170 104 -2.09 105.753 -37.465
D= 300 mm f'c = 29 MPa
B= 300 mm
P= 115 mm base plate grade
G= 115 mm fyi = 240 MPa
T= 25 mm

dc = 250 bfc = 250 tfc = 14 bwc = 9


a1 = 31.25 a2 = 50 am = 50
A1 = 90000 mm2 A2 = 122500 mm2
AH = 20231 mm2 a3 = 22.2 mm

f Nc = 1,556 kN design strength of concrete foundation


> Fy ? Yes

f Ns = 2,430 kN design strength of base plate in compression


> Fy ? Yes

Assumse shear force is resisted by friction alone


f Vd1 = 184.63808 kN design shear capacity relying on friction
> Fx ? Yes

Assume 6mm fillet weld category SP is provided along the web (200-12*2)mm each side

Lw = 444 mm length of weld


f vw = 0.835 kN/mm shear capacity per unit length of weld E41XX/W40X

f vw Lw = 371 kN design shear capacity of weld E41XX/W40X


> Fx ? Yes

Use Anchor bolt 4-M20 grade 4..6 (fy = 240 MPa) with
L= 640 mm
P= 110 mm
nb = 4
dia = 20 mm

Checking for Tension & Shear

bfo = 250
dc = 250
sg = 115
nb = 4
db = 20

f Ns = 1,761 kN design strength of base plate in tension


> Fy ? Yes

fy = 240 MPa yield stress


fuf = 400 MPa tensile stress

f Ntf = 100.5 kN single bolt tension capacity


f Ntb = 402.1 kN overall bolt tension capacity
> Fy ? Yes

Surface area of
Concrete pull out projected cone

A) Single Bolt
f'c = 29 MPa
dia = 20 mm
dm = 530 mm
Lh = 0 mm (length of hook)
Aps = 882473 mm2
f Ncc = 1256 kN > f Ntf Yes
ae min = 0.00 mm
View of the shear cone."

B) Group Bolt Rectangular area of projected


pyramid

Determining stress cone area

Total enclosing area (A1)


Triangular Sub-area (A2)

Ld = 530 mm x= 115 mm
y= 115 mm
A1 = 1139498 mm2
A2 = 120 mm2
Aps = 1139019 mm2 (A1 - 4xA2)
Aps(design) 320000
f Ncc = 455 kN > f Ntb Yes

Assumse shear force is resisted by all anchor bolts

f Vfn = 62.3 kN shear capacity of single bolt


f Vfb = 249.3 kN shear capacity of overall bolts
> Fx ? Yes

Combined tension and shear on anchor bolt

Fy + Fx = 0.747
f Ntb f Vfb

S-ar putea să vă placă și