Sunteți pe pagina 1din 7

DESTINATION COPY

PREPARED BY: ISSUED BY: SCALE:


Paulo Murilo Alexandre Fernandes _
CHECKED BY: DATE: CLASSIF. SOC.:
Paulo Murilo 07/01/2016 DNV
CUSTOMER: YARD No.:

AL-023/AL-024/
OC-003/OC-004
PROJECT: PROJECT No.:

Havyard 843 - AHTS 18000 13147


TITLE: DOCUMENT No.:

5E-886-006
ORDER SPECIFICATION FOR REVISION: SHEET No.:
SPECIAL ELECTRIC CABLES
0 1/7
TOTAL
5E-886-006 O.S. SPECIAL ELECTRIC CABLES SHEET 2 / 7

REVISION REASON FOR ISSUE

REVISION 0
DATE 07/01/2016
EXECUTED P. Murilo
CHECKED P. Murilo
APPROVED Alexandre
SUMMARY

1- GENERAL

2- GUARANTEE

3- DESIGN AND MANUFACTURING

4- TECHNICAL SPECIFICATION

5- DOCUMENTS AND DRAWINGS

6- INSPECTION AND TEST

7- CERTIFICATIONS

AL-023/AL-024/OC-003/OC-004 | 5E-886-006_0 O.S. Special Electrical Cables Sheet 3/7


1- GENERAL

The Manufacturer shall present an offer covering all the requirements of this Order Specification,
where else applicable.

2- GUARANTEE

The Contractor shall guarantee the Equipment at least until the date designated below, whichever
comes first:

A) 24 months after the shipment of the Equipment.


B) 12 months after the delivery of the vessel to the Owner.

Any defect and/or failures discovered within the Guarantee period, whose causes shall be
attributed to the Contractors responsibility, shall be immediately repaired or replaced by the
Contractor at the Contractors expenses.

The repaired or replaced parts shall be guaranteed additionally for 12 (twelve) months after the
repairs or the replacements have been carried out.

3- DESIGN AND MANUFACTURING

The above mentioned items have to be designed and manufactured according to the following
standards and rules (where applicable):

a) Det Norske Veritas (DNV);


The ship has the following class notation:
1A1 Offshore Service Vessel AHTS E0 SF DK(+) DPS 2 TMON BIS
b) MARPOL 73/78,Annex VI ,NOx emission limitation
c) ISO 3046/1
d) IMO TIER II
e) IMO SOLAS Chapter II-2, Part A15 (new B4), Regulation 2.9 to 2.11 and 3.
f) Regulation SOLAS
g) International Electro Technical Commission (IEC)
h) International Telecommunication Regulations and Radio Regulations.

4- TECHNICAL SPECIFICATION

The scope of supply consists of cable to install in the vessel.

Standards:
- IEC 60092-350; IEC 60092-353;
- Halogen free properties: IEC 60754-1-2;
- Low Smoke emission: IEC 6134-1/2;

AL-023/AL-024/OC-003/OC-004 | 5E-886-006_0 O.S. Special Electrical Cables Sheet 4/7


- Materials: IEC 60092-359 and IEC 60092-351;
- Flame retardant: IEC 600332-3 -22 cat A and IEC 60332-1
- Fire resistant: IEC 60331
All cables to comply with Class requirements.
All cables should manufactured with marking distance to each meter, pined in the cable
Each wire should be numbered

Remarks:
All cables shall be DNV certificated and supplied with certificate.
All cables shall be manufactured with the following text printed throughout entire cable
length: OCEANA ESTALEIRO

Scope of Supply:

4.1 Ethernet twisted pair

For Ethernet with twisted pair it is recommended to use a S/FTP (individual twisted pair foils and
overall braid) cable of category 7.

Cable Data:
Type: ISO/IEC11801 Class F S/FTP CAT7, twisted pair, shielded, 4x2x0.5 mm
Impedance: 100 ohm
Range: Max 90 m

Recommended cable:
Manufacture : Nexans
Description : LANmark-7 Maritime CAT7 S/FTP
23 AWG LSFROH SHF1 Grey
Conductor : 4 pairs AWG23 (0.58q)
Cable outer diam. : 7.9 mm
Impedance : 100
Approved by : DNV certificate E-8001
Part No. manufacture : N10m.002
Maximum cable length : Max 90m
Quantity: 8.000 meters

4.2 Ethernet fiber optical

The fiber optical cables must be of multimode type with a core diameter of 50 m, and cladding diameter
125m. ST connectors (also known as BFOC) are to be used in both ends of the cable.

Cable Data:
Type : Multimode Cable
Core Diameter : 50 m
Cladding Diameter : 125 m

Recommended cable:
AL-023/AL-024/OC-003/OC-004 | 5E-886-006_0 O.S. Special Electrical Cables Sheet 5/7
Leoni: AT-V(ZN)H(ZN)H N of cores:6 Conductor cross section G50/125
Quantity: 300 meters

4.3 Can bus

For the CAN bus, it is recommend using a shielded twisted pair cable. According to the ISO 11898-2
standard, cables to be chosen for CAN bus lines should have a nominal impedance of 120 Ohm, and a
specific line delay of nominal 5 ns/m. Line termination has to be provided through termination resistors of
120 Ohm located at both ends of the line. The length related resistance should have 70 mohm/m.

Cable Data:
Type: Twisted pair, shielded, low capacitance, 0.75 mm.
Cable outer diam.: max 14 mm (when connector is used).
Impedance: 120 (min. 108 , max. 132 )
Capacitance: max. 60 pF/m.
Resistance: max 40 /km.
Range: Max 300m.

Recommended cable:
Manufacture: UI Lapp Germany
Description: Unitronic BUS CAN UL/CSA
Conductor: 2x2x0,75q
Impedance: 120
Max. cable length: 300m
Approved by: UL/ULC
Part no. Manufacture: 2170 270 2x2x0,75
Supplier worldwide: Miltronic AS Norway
Quantity: 4.000 meters

4.4 Coaxial Cable

4.4.1 Low loss coaxial cable RG-214- 50 Ohm, with conductor stranded cooper, LSFH.
or equivalent HUBER+SUHNER G_07262_D
Quantity: 800 meters

4.4.2 Low loss coaxial cable RG-11- 75 Ohm, with conductor stranded cooper, LSFH.
Quantity: 200 meters

4.4.3 Low loss coaxial cable RG-06- 75 Ohm, with conductor stranded cooper, LSFH.
Quantity: 500 meters

4.5 Profibus Cable

4.5.1 Fieldbus Cable

AL-023/AL-024/OC-003/OC-004 | 5E-886-006_0 O.S. Special Electrical Cables Sheet 6/7


Recommended cable:
Manufacture: Kerpen
Description: KS-02YSCH 4x2xAWG 24/7 PiMF-100ohm
Quantity: 500 meters

4.6 Unitronic Cable


Cable Data:
Type: Twisted pair, shielded, low capacitance, 0.75 mm.
Cable outer diam.: max 8,5 mm (when connector is used).
Inductivity: Approx. 0,50mH/Km.
Conductor stranding: Fine copper wire strands.
Flame retardant according IEC 60332-1-2
Recommended cable:
Manufacture: Lapp Cable
Description: Unitronic LiYCY (TP)
Conductor: 2x2x0,75q
Part no. Manufacture: 0035820 2x2x0,75
Quantity: 200 meters

Note: Quantities for one hull.

5- DOCUMENTS AND DRAWINGS

All necessary drawings and technical information for the correct application and installation of the
equipment .
Quality assurance certificates.
DNV certificates.
Manufacturer certificates and Guarantee certificate shall be also provided for each one equipment
when applicable.

6- INSPECTION AND TEST

All necessary inspections and tests shall be carried out during manufacturing process according to
manufacturers standards and Classifications Society requirements.

7- CERTIFICATIONS

As required by DNV Rules.


The type approval certificates of equipment shall be delivered with the technical/commercial proposal.
Asbestos Free Declaration according to SOLAS II-1, Regulation 3-5 and MSC.1/Circ.1379