Railway Power Supply Systems

Find out more on http://toshiba-railway.com

TOSHIBA CORPORATION Infrastructure Systems & Solutions Company


72-34, Horikawa-cho, Saiwai-ku, Kawasaki 212-8585, Japan Tel: +81-44-331-1486
The information contained herein is as of July 7, 2014.
The information contained herein is subject to change without notice.
The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents

or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TOSHIBA or others.
TOSHIBA products should not be embedded to the downstream products which are prohibited to be produced and sold, under any law

TOSHIBA does not take any responsibility for incidental damage (including loss of business prot, business interruption, loss of business information, and other pecuniary damage)

arising out of the use or disability to use TOSHIBA products.


The products described in this document may include products subject to the foreign exchange and foreign trade laws.

The products described in this document may contain components made in the United States and subject to export control of the U.S. authorities. Diversion contrary to the U.S.

law is prohibited.
2016.08
1 Railway Power Supply Systems DC Electrification Systems Control Center
Rectifier Transformer Supervisory Control And Data Acquisition (SCADA)
Traction Rectifier
Regenerative Inverter
Rail transport has been evaluated as an environment-friendly transportation system, helping to solve environmental DC Switchgear
Protection Relay
pollution, energy resources shortage, and chronic traffic congestion problems in developing countries. HSVCB
Since Toshiba started manufacturing traction motor and propulsion systems in 1899, we have made continuous Package-Type DC Substation
SCiB Traction Energy Storage System
technological innovations which led to the creation of new transportation systems, including power supply
systems. We have now expanded our business to supply advanced technologies on a global scale.
In the pursuit of technological innovation, global environmental issues are important, and demand is high for the
creation of a new product value aimed at reducing environmental impact while ensuring safety and comfort.
We offer products and systems to support your organizations activities aimed at protecting the environment,
thus contributing to the creation of a sustainable, eco-friendly society.

AC Electrification Systems Transmission Systems


Traction Transformer Gas Insulated Switchgear (GIS)
Auto-transformer Gas Insulated Transformer (GIT)
Feeding Circuit Breaker Gas Circuit Breaker (GCB)
Feeding Switchgear(GIS,C-GIS,SIS) Cubicle Type Gas Insulated Switchgear (C-GIS)
Changeover Switch Solid Insulated Switchgear (SIS)
Control / Relay Panel
AC Feeding Protection Relay

1 2
2 System Integration
Route map Timetable Our long histor y of engineering
Toshiba has been continuously striving to provide customers with advanced, optimal solutions. We are able railway system projects has given
us extensive expertise in designing
to provide not only the latest environmentally-friendly products from all over the world but also consulting
railway power supply systems. Our in-
services like energy simulation and construction works as well. house simulator is able to calculate
various railway system conditions
w i t h re m a r k a b l e a c c u r a c y. O u r
Substation experienced engineers are also there
Voltage to provide consultation and offer
customer-oriented solutions.
Current

Power

Train

Example of Power Supply Simulation

Engineering
Toshiba is able to supply transmission and distribution products from
our bases all over the world, using our worldwide distributors to offer
customer-oriented solutions at a competitive price.

Construction
Procurement
& Manufacturing

Taiwan High Speed Railway Project

Solid Insulated Switchgear Vegetable Oil Transformer SCiB Traction Energy Storage System

Having started in the transportation business in 1899, Toshiba has extensive experience in offering innovative railway system products. For In addition to supplying products, Toshiba also provides customers with FTK solutions. One representative example of our FTK comma the
power supply systems, our current products such as the Solid Insulated Switchgear, Vegetable Oil Transformer and SCiB Traction Energy Taiwan High Speed Railway, wherein Toshiba built and supplied essential products for railway electrification.
Storage System, are environment friendly solutions which contribute to a more sustainable environment.
3 4
3 Transmission Systems
3-1 Gas Insulated Switchgear (GIS)
Railway Power Supply equipment must be highly reliable and safe. In addition, today's equipment must The Gas Insulated Switchgear (GIS) is an integrated switchgear which uses SF6 insulation gas. It is used mainly in 72.5kV or higher
also be economically efficient to accommodate installation in limited space and in a short period of time. systems. Toshiba has a long history for developing and manufacturing GIS.
Therefore, Toshiba developed the highly reliable SF6 Gas Insulated Switchgear (GIS) which can simplify site
work and reduce land footprint by up to 92%. For the main transformer, Toshiba offers a non-flammable
Gas Insulated Transformer (GIT)
for a more compact substation
solution. As for Toshibas product
l i n e - u p fo r m i d d l e vo l t a g e
switchgears, we developed the
Cubicle t ype G as I nsulated
Switchgear (C-GIS) and SF6 gas
free Solid Insulated Switchgear
(SIS).

168kV GIS 170kV GIS

Ratings
P6 Features
P11

Transmission Systems Rated Voltage [kV] 72.5 ~ 252 Rated Voltage [kV] 36 / 72
Rated Interrupting Current [kA] 25 ~ 63 Rated Bus Current [A] 1200
Rated Lightning Impulse Withstand Voltage [kV] 325 ~ 1050
Rated
Compact Design
Breaking Current [kA] 16 / 25
Can be installed in indoor and underground substations
Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Lightning Impulse [kV] 200 / 350
Typical space for AIS+OIT Rated Gas Pressure 0.7(GCB) / 0.7(GIS)
Rated Withstand Voltage
Outdoor Compatibility Power Frequency [kV] 70 / 140
2,236m2 Applicable Standards JEC / IEC Rated Gas Pressure
Protection against[MPa G]
pollution 0.05 (at 20C)
OIT
Safe Operation
Electrified parts are enclosed in the earthed tank
P11
P7
52m Rated
LowVoltage
Maintenance
[kV] 36
GSR GSM / GSP GSPF Rated Current [A] 1200
OIT Rated Voltage [kV] 240 / 300 72 / 84 / 168 145 Between Main Circuit and Earth 200
Lightning
Method of Operation Hydraulic Motor Spring Motor Spring Rated Impulse [kV] Between Main Circuit Terminals 250
Safe Withstand
Tank Dead Tank Live Tank Power Between Main Circuit and Earth 70 1min.
Using safe material Voltage
Lighting (LTO) Frequency [kV] Between Main Circuit Terminals 100 10min.
Rated 900 / 1050 350 / 400 / 750 650
Impulse [kV]
Low Temperature High Effective
Withstand

Gas Insulated Transformer (GIT)


Operation Capacity Rated Short Time Withstand 12.5 2sec.
Voltage Power 200-265-200(1min)/
AIS 140 / 160 / 325 275
3-2
Current [kA]
Frequency [kV]
Usable in extremely 250-330-250(1min)
Attractive features are realized by High amount of actual
cold enviroments
Applicable Standards
usable energy over
JEC / IEC wide range of SOC
using Lithium Titanate Oxide Mechanical 200,000 times
(-30C) Switching Lifetime
(LTO) in its anode Electrical 100,000 times
The Gas Insulated Transformer (GIT) uses SF6 gas for insulation and cooling instead of mineral oil and is suitable for indoor and
underground substations. GIT development and manufacturing at Toshiba also has a long history.
P8
Rapid High P17
16m Recharging Input & Output
Rated Voltage [kV] 24 36 40.5 72 84
Recharges Usable with Features
Rated Voltage [V] DC 750 , 1500
43m Rated
in approx. 6 minutes
Lightning Impulse [kV] 125 170 185 high current
350 400
Withstand Rated Current [A] 3000 , 4000
Long Life
Voltage Power Frequency [kV] 50 70 95 140 160 Rated Breaking Capacity [kA] 50 (at 3106A / sec), 100 (at 1010 6A / sec)
GIT Over 6,000 charge-
discharge630
cycles
/ 1250 / 1250 /
Rated
Non-flammability
Short Time Current [kA] 50-1sec , 100-1sec
GIS Rated Current [A] 800 / 1250 SF6 gas isStandard
used instead of mineral oil,bealleviating
2000 2000 Applicable JIS (To developedthe
forneed
IEC)
for a fire fighting system. This also allows the installation in
Rated Short Time Withstand
25 / 31.5 the same room with the GIS for a more compact substation
11m Current [kA]
layout.
GIT Applicable Standard JEC / IEC / GB
Non-explosive
P17
No pressure relief device is needed.
Specifications Applicable equipments
Compact Design Air Insulated type or
A compact solution with GIS and GIT Our GIS+GIT - Sample Layout MV Switchgear Unit 7.2 / 24 / 36kV
Conservator and pressure relief device are not required thus type
Solid Insulated
AIS : Air Insulated Swithgear 176m2 (8% of AIS + OIT land footprint) lowering the height to less than that of OITs.
TR : Epoxy Resin Molded Dry
OIT : Oil Insulated Transformer 12-Pulse Rectifier Unit Up to 2,000kW / Liquid Silicone
GIS : Gas Insulated Switchgear SR : Heat-pipe Self-cooling
GIT : Gas Insulated Transformer P10 DC Switchgear Unit DC 600V, DC1500V HSCB or HSVCB

Application Feeding System for High Speed Railway GIT Auxiliary Power DC 110V,
5 T-type Bushing Busbar 6 Battery
Lead Storage
Supply Unit AC 105V / 210V
ES EVT Rated Voltage [kV] 220 / 25x 2 ; 161 / 60x 2 ; 132 / 27.5x 2
TT Cooling Type ONAN / ONAF / OFAF
DS
Rated Power [MVA] 84 / 60
ES DS
VCB Overload 200% 5mins
P13
VCB CHD Connection Scott
3-3 Gas Circuit Breaker (GCB) 3-5 Solid Insulated Switchgear (SIS)
Gas Mineral Oil
Toshiba supplies many
Liquid Silicone
types of Gas Circuit
Vegetable Oil
Breakers (GCB) for 72kV or higher voltage.
Epoxy Resin Toshiba developed Solid Insulated Switchgear (SIS), which utilizes high-performance epoxy resin independently developed
Applicable for up to 6MW Rectier as insulating material for SIS. Our epoxy resin provides a remarkable improvement in strength, flexibility, heat-resistance
OIT
77kV 35kV and dielectric strength. By using this material for switchgear insulation, we are able to reduce the size while maintaining the
Applicable for DC600V / 750V / 1500V / 3000V equipments high reliability. Installation space required for the 72/82kV SIS is smaller than our conventional 72kV air-insulated
JEC / IEC switchgear. For the 24/36kV SIS, the new Balanced Magnetic Actuator (BMA) for
P6 the VCB is utilized which further reduces the size
P11
52m and weight of the SIS without compromising its performance.
Rated Voltage [kV] 72.5 ~ 252 Rated Voltage [kV] 36 / 72
OIT
Rated Interrupting Current [kA] 25 ~ 63 Rated Bus Current [A] 1200
Rated Lightning Impulse Withstand Voltage [kV] 325 ~ 1050 Rated Breaking Current [kA] Busbar 16 / 25
self cooling VDS
P6 P11 Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 LightningSafe
Impulse [kV] 200 / 350
P14 Rated Withstand Voltage Using safe material
Rated Gas Pressure 0.7(GCB) / 0.7(GIS) Operation Power Frequency
(LTO) [kV] 70 / 140
1500V / 3000V Rated Voltage [kV] 72.5 ~ 252 Rated Voltage [kV] 36 / 72 Mechanism
Applicable Standards JEC / IEC Rated Gas Pressure
Low Temperature [MPaG] 0.05 (at 20C)
High Effective
Rated Interrupting Current [kA] 25 ~ 63 Rated Bus Current [A] 1200 Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
Operation Capacity
Rated Lightning Impulse Withstand Voltage [kV] 325 ~ 1050 Rated Breaking Current [kA] AIS 16 / 25 Rated Power Protection
Applicable for up to 6MW Usable
Rectier
in extremely Attractive features are realized by High amount of actual
Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Lightning Impulse [kV] 200 / 350 Relay cold enviroments usable energy over
Rated Withstand Voltage Primary 77kVP11 Titanate
using Lithium 35kV OxideVD
Rated Voltage (-30C) wide range of SOC
Rated Gas Pressure 0.7(GCB) / 0.7(GIS) Power Frequency [kV] 70 / 140 P7 (LTO) in its anode
Secondary Applicable for DC600V / 750V / 1500V / 3000V
Applicable Standards JEC / IEC Rated Gas Pressure [MPaG] 0.05 (at 20C) Rated Voltage [kV] 36
Applicable Standard GSR GSM / GSP GSPF JEC / IEC ES
Rated Current [A] 1200
240kV GCB 72kV GCB 145kV 3-Phase GCB VCB
Rated Voltage [kV] 240 / 300 72 / 84 / 168 145 Lightning Between Main Circuit and Earth 200
Rated
P11 P14 Method of Operation Hydraulic Motor Spring Motor Spring Impulse [kV] Between Main Circuit Terminals 250
Ratings
P7
16m Tank Dead Tank Live Tank
Voltage
Rapid
Withstand
Power
Recharging
Main Cable
Between Main Circuit and Earth 70 &1min.
Input Output
High
Rated Voltage [kV] 36 Cooling Method Lighting Vertical heat-pipe self cooling
GSR GSM / GSP GSPF Features Good Breaking
Rated Current [A] 1200
Ability Rated
Rated Power Impulse [kV]~ 6 MW
900 / 1050 350 / 400 / 750 650
Frequency [kV]
Recharges Between Main Circuit
CT Terminals 100 10min.
Usable with
43m Withstand in approx. 6 minutes high current
Rated Voltage [kV] 240 / 300 72 / 84 / 168 145 Rated Short Time Withstand
Easy Installation
Lightning Between Main Circuit and Earth 200 Rated Voltage
Voltage Power 200-265-200(1min)/
DC 600V / 750V / 1500V / 3000V
140 / 160 / 325 275 Current [kA]
12.5 Long
2sec.Life
Method of Operation Hydraulic Motor Spring Motor Spring Rated Impulse [kV] Between Main Circuit Terminals 250 Frequency [kV] 250-330-250(1min)
Applicable Standard JEC / IEC GIT Over 6,000 charge-
Tank Dead Tank Live Tank
Withstand
Voltage
Low NoiseBetween Main Circuit and Earth 70 1min.
Power Applicable Standards JEC / IEC 24kV SIS Switching Lifetime
Mechanical 200,000 times
discharge cycles
1,000kWcontinuous rating GIS Electrical 100,000 times
g Inverter mode Lighting Frequency [kV] Between Main Circuit Terminals 100 10min.
Rated
3,000kW1minute or 4,500kW-30seconds 900 / 1050 350 / 400 / 750 650
Impulse [kV]
Withstand Rated Short Time Withstand
nverter mode 1,000kWcontinuous rating
Voltageonly Power 200-265-200(1min)/ 12.5 2sec.
140 / 160 / 325 275 Current [kA] 11m
Frequency [kV] 250-330-250(1min) GIT
ol mode (Make a selection for your operation ) Applicable Standards JEC / IEC Switching Lifetime
Mechanical 200,000 times Ratings
P8
Electrical 100,000 times P17
rol: To 6 or 8 output regulation
voltage control Rated Voltage [kV] 24 36 40.5 72 84 Features SF6 gas-less due to epoxy-
Rated Voltage [V] DC 750 , 1500
Rated Lightning Impulse [kV] 125 170 185 350 400
Rated Current [A]
resin coating
3000 , 4000
Withstand
allel * 6Arm * 2Bridge

1,200A) / MG1200FXF1US53(P) 3-4


e parallel configuration by Transformer Cubicle Type Gas Insulated Switchgear (C-GIS)
P8

Rated Voltage [kV]


P17 P15
Voltage

Rated Current [A]


Power Frequency [kV] 50 70
630 / 1250 /
2000
95
1250 /
2000
140

800 / 1250
160 Rated Breaking Capacity
Compact Design
[kA] 50 (at 3106A / sec), 100 (at 1010 6A / sec)
Rated Short Time Current [kA] 50-1sec , 100-1sec
Outdoor Compatibility
24 36 40.5 72 84 Applicable Standard JIS (To be developed for IEC)
Rated Voltage [V] DC 750 , 1500
pure water (natural cooling type) Rated Lightning Impulse [kV] 125 170 185 350 400
Rated Current [A] 3000 , 4000
Rated Short Time Withstand
Current [kA]
25 / 31.5 1,000kWcontinuous rating Safe Operation
0W * 2,200D * 2,900H Withstand
The Cubicle Type Gas Insulated Switchgear (C-GIS) is an integrated switchgear which uses SF6 Regenerating Inverter mode
Power Frequency [kV] 50 70 95 140 160 Capacity 3,000kW1minute or 4,500kW-30seconds
of Inverter-800W * 1,000D * 2,300H
Voltage Rated Breaking Capacity [kA]
insulation gas. It is used mainly in 36kV to 84kV systems. Toshiba spent many years developing
50 (at 3106A / sec), 100 (at 1010 6A / sec) Applicable Standard JEC / IEC / GB Low Maintenance
630 / 1250 / 1250 / Rated Short Time Current [kA] 50-1sec , 100-1sec Powering Converter mode 1,000kWcontinuous rating only
2,800W * 2,000D * 2,500H and manufacturing
Rated Current [A] high quality C-GIS. Vacuum2000
circuit800
breakers
/ 1250 (VCB) are used for the C-GIS.
2000 Applicable Standard JIS (To be T-type Bushing
developed for IEC) Busbar
1,500VDC
P17 High Reliability
Rated Short Time Withstand ES EVT Output control mode (Make a selection for your operation ) Specifications Applicable equipments
25 / 31.5 Rated Input Voltage
Current [kA] -1) Load control: To 6 or 8 output regulation
DS TT
Applicable Standard JEC / IEC / GB -2) Constant voltage control MV Switchgear Unit 7.2 / 24 / 36kV Air Insulated type or
ES DS Solid Insulated type
P17 P13 P8
Rated Output Voltage
VCB 1,200VAC
36 40.5 72 84 VCB Eco-Friendly
CHD
Main Circuit Configuration
Design
1Series * 2Parallel * 6Arm * 2Bridge Safe Design
12-Pulse Rectifier Unit Up to 2,000kW
TR : Epoxy Resin Molded Dry
/ Liquid Silicone
[kV] 170 185 350 400 Specifications Applicable equipments Double bridge parallel configuration by Transformer SR : Heat-pipe Self-cooling
ES
Device IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
kV] 70 95 140 160 MV Switchgear Unit 7.2 / 24 / 36kV Air Insulated
CHD type or P10
The Greenhouse Eect DC Switchgear Unit DC 600V, DC1500V HSCB or HSVCB
630, 1250, 2500 630, 1250, 2000 800, 1250 800, 1250 Solid Insulated type
ESResin Molded Dry
Sun
Device Cooling System
Application
Heat-pipe in pure water (natural cooling type)
Feeding System
Inverter-2,700W for High
* 2,200D
C-GIS
Speed
* 2,900H Railway Auxiliary Power DC 110V, Lead Storage Battery
25, 31.5 25, 31.5 20, 25, 31.5 20, 25, 31.5 TR : Epoxy Supply Unit AC 105V / 210V
JEC / IEC 12-Pulse Rectifier Unit Up to 2,000kW / Liquid
DS Silicone Rated Voltage
Dimension CT [kV] 220Panel
Control / 25xof2 Inverter-800W
; 161 / 60x 2 ; 132 / 27.5x*22,300H
* 1,000D
SR : Heat-pipe Self-cooling Cooling Type ONAN / ONAF /*OFAF
ES DC Reacrtor-2,800W 2,000D * 2,500H
P10 DC Switchgear Unit DC 600V, DC1500V HSCB orCT
HSVCB Rated Power [MVA] 84 / 60
Overload 200% 5mins Atmo
Application Feeding System for High Speed Railway
72kV C-GIS
Auxiliary Power
Cross-section
Supply Unit
DC 110V,
AC 105V / 210V
Lead Storage Battery
Connection Scott Green sph P13 Zero SF6 5kg 0kg
Rated Voltage [kV] 220 / 25x 2 ; 161 / 60x 2 ; 132 / 27.5x 2 h ous er
Cooling Type ONAN / ONAF / OFAF
P7 Applicable Standard JEC / IEC e Ga
e Half Weight
21F 1,900kg
Distance 850kg
Protection
51F Overcurrent Protection
Ratings
P7
Rated Power [MVA] 84 / 60 Rated Voltage [kV] 36 se 40.5 72 Half Components
Protection Function 84 2500pcs 1200pcs
s 27F Voltage Protection

27.5
Overload
Rated Voltage [kV]
200% 5mins
36 40.5 72 84 Features
P13 21F
Compact Design 50F
Rated Withstand Voltage
Lightning Impulse [kV] 170 185 350 37% Less Volume
79
4002.7m3 1.7m3
Automatic Reclose
Connection Scott P10 Power Frequency [kV] 70 95 140 160
Rated
1250 Applicable
Lightning Impulse [kV]
Withstand Standard JEC / IEC
170 185 350 400 Outdoor
21FCompatibility
Distance Protection Rated Current [A] Earth
630, 1250, 2500 630, 1250, 2000 800, 1250 800, 1250
e [kV] 250 Voltage Power Frequency [kV] 70 95 140 160 51F Overcurrent Protection Example
Rated Short Time ofWithstand
Roof-delta Connection
Current [kA] Transformer 25, 31.5 25, 31.5 20, 25, 31.5 (Comparing with
20, 25, 31.5 products at 24kV)
[kV] 95 630 / 630 /
Safe
Protection Function Operation
27F Voltage Protection UtilityStandards Feeding System for High Speed Railway SIS BusbarJEC
Compartment
TOSHIBA
800 / 800 / Applicable / IEC
Rated Current [A] 1250 / 1250 /
25
P10 2500 2000
1250 1250 Low Maintenance
79 Automatic Reclose SFRated
6 gasVoltage [kV]
is evaluated as the 220kV
most/ potent
60kV2 greenhouse gas and it SIS has an "Internal arc-free" feature which promotes safe
Cooling Type ONAN
poses negative effects in the environment. As part of Toshibas operation. Busbar and devices in each phase of the main
Rated Short Time Withstand
Current [kA]
25 /
31.5
25 /
31.5
20 / 25 / 20 / 25 /
31.5 31.5
Easy Withstand Voltage Test Ratedfor
drive Power development of60more eco-friendly products, Toshiba
the[MVA] circuit P10
are completely insulated with earthed layer of
Example of Roof-delta Connection Transformer
Overload a new material which
introduced 300%possesses
2min high dielectric strength. Toshiba'sRated
unique epoxy
[kV] resin mold 27.5
coating.
Applicable Standards JEC / IEC
Utility Feeding System for High Speed Railway Voltage
Connection Roof-delta
7 Rated Voltage [kV] 220kV / 60kV2 Rated Lightning 200 (to earth and across open8 contacts)
Applicable Standard JEC / IEC P7Withstand Impulse [kV] 220 (across isolating distance)
Cooling Type ONAN P12
Voltage
Rated Power [MVA] 60 P10 Rated (Line to [kV] Power
Voltage 95 36
(to earth40.5
and across72open contacts)
Rated Voltage [kV] 27.5 84
Overload 300% 2min Earth) Frequency [kV] 110 (across isolating distance)
Rated Voltage [kV] 27.5 Rated Lightning Impulse [kV] 170 185 350 400
Rated Current [A]
P10 1250
Connection Roof-delta Withstand
Rated Current [A] 1250
Rated Lightning 200 (to earth and across open contacts) Lightning Impulse [kV] 250 Voltage Power Frequency [kV] 70 95 140 160
Applicable Standard JEC / IEC Withstand Impulse [kV] 220 (across isolating distance) Rated Rated
Withstand Voltage
Voltage [kV] 55 / 27.5 Rated Short Time Withstand
Rated Gas Pressure
Withstand 0.7(GCB) / 0.7(GIS) Rated S
Voltage Power 200-265-200(1min)/
Applicable Standards 140 / 160JEC
/ 325
/ IEC 275 Current
Rated G
Frequency [kV] 250-330-250(1min)
P8Applicable Standards JEC / IEC Switchi
P17
P11
Rated Voltage [kV]
P7 24 36 40.5 72 84
Rated V
Rated Lightning Impulse [kV] 125 170 185 350 400 Rated V
Withstand GSR GSM / GSP GSPF Rated C
P8Voltage Rated C
Power Frequency [kV] 50 70 95 140 160 Rated B
Rated Voltage [kV] 240 / 300 72 / 84 / 168 145 P17

4
Rated S

AC Electrification Systems
Method of Operation 630 / 1250
Hydraulic / 1250
Motor Spring/ Motor Spring Rated
Rated Voltage
Rated Current [kV]
[A] 24 200036 40.5 800 / 1250
72 84
2000 Withsta
Applica
Rated V
Tank Dead Tank Live Tank
Rated Lightning
Rated Short Time Impulse [kV] 125
Withstand 170 185 350 400 Voltage

AC Traction Transformer
25 / 31.5 Rated C
Current [kA]Lighting
Withstand
P11 P15 Rated 900 / 1050 350 / 400 / 750 650

4-1
Voltage Impulse
Power[kV]
Frequency [kV] 50 70 95 140 160 Rated B
Withstand
Applicable Standard JEC / IEC / GB Rated S
Voltage Power 200-265-200(1min)/
630 / 1250 / / 160
1250 / Rated S
Rated Current [A] 140 / 325 275
800 / 1250 Current
Frequency [kV] 250-330-250(1min)2000 2000 Applica
P17
Toshiba provides a highly-reliable and modernized AC electrification system which consists of elements Applicable Standards JEC / IEC Switchi
AC feeding power for rolling stock is single-phase power. The ACRated Short substation
feeding Time Withstand should therefore convert 25 / the
31.5 commercial
Current [kA]
such as large capacity of traction transformers, single phase circuit breakers, surge arrestors, and AC 3-phase into AC single-phase. However in this case, it will cause three phase voltage unbalance at the primary side.The Scott-
Applicable Standard JEC / IEC / GB
Power Source
connection and the Roof-delta connection transformer below are used for the AC traction transformer which can reduce the MV Sw
changeover switches. Our products are designed with thesubstation
substation advance technology based on our long history
3-phase voltage unbalance induced in the primary side. P17
of development. It contributes to a safe, stable and cost-minimized system operation for a long term. P8
12-Puls
P17
Sectioning Post Transformer Rated Voltage [kV] 24 36 40.5 72 84
Ratings
P10
Rated Lightning Impulse [kV] 125 170 185 350 400
MV SwiV
Rated
DC Swi
VS-A VS-B Withstand Rated C
Application Power Frequency [kV] Feeding50System70 for High Auxilia
Voltage 95Speed140Railway160 Rated B
IGBT Supply
12-Puls
Rated Voltage [kV] 220 / 25x 2 ; 161 / 60x 2 ; 132 / 27.5x 2
Features Toshiba can supply various types of transformers and propose the most suitable type of Regenerative
Inverter
Escalator
Rated CurrentLighting
[A]
630 / 1250 / 1250 /
800 / 1250
Rated S
transformer according to customer specification such as voltage, capacity, loss, installation Cooling Type ONAN / ONAF2000/ OFAF 2000 Applica
P10 DC Swi
condition, etc. Traction Substation
Rated
Rated Power
Short
Passenger
[MVA]
Time
Station Withstand
Facility
84 / 60
25 / 31.5
Current
Overload [kA] 200% 5mins Auxiliar
Application Feeding System for High Speed Railway P13
The changeover switches are used for the phase break point of high speed railway system. Applicable
Connection
Rated Standard
Voltage [kV] Scott
220 JEC2/ ;IEC
/ 25x 2 ; 161 / 60x 132/ GB
/ 27.5x 2
Supply
Our product is designed for long time operation under the harsh conditions of high voltages Applicable
Cooling Standard
Type JEC / IEC
ONAN / ONAF / OFAF
P17
and repeating surges. Rated Power [MVA] 84 / 60 Protect
The control and relay panels supplied by Toshiba are designed with the advance digital Overload 200% 5mins
P13
Decelerating / Regeneration by Brake Accelerating
Connection / Powering Scott
technologies. They integrate all required functions such as protection, control and monitoring by P10 MV Swi
the intelligent digital relays, PLCs and the LAN connection network. Applicable Standard JEC / IEC
Scott Connection Transformer
Example of Roof-delta Connection Transformer Protect
12-Puls
Utility Feeding System for High Speed Railway

P9 Ratings
Rated Voltage [kV]
P10
P10 220kV / 60kV2
DC Swi
TOSHIBA's POWER SUPPLY SYSTEMS for AC Feeding Substation Cooling Type ONAN
Auxiliar
Application
Example of Roof-delta
Rated Power [MVA] Feeding
Connection
60 System for High Speed Railway
Transformer P10
Supply
Rated
Overload
Utility Voltage [kV] 220
300% / 25x
Feeding 2min2 ; 161 for
System / 60x 2 ; 132
High / 27.5x
Speed 2
Railway
Rated V
Cooling
Connection
Rated Type [kV]
Voltage ONAN // 60kV2
Roof-delta
220kV ONAF / OFAF
P13 Rated Power
Applicable
Cooling Type [MVA]
Standard 84
JEC/ /60
ONAN IEC
Rated
Withsta
Overload
Rated Power [MVA] 200% 5mins
60 Voltage
P10
P13
Connection Scott 2min (Line to
Overload 300%
TO POWER COMPANY 3 phase NETWORK Earth)V
Rated
Applicable Standard
Connection JEC / IEC
Roof-delta
P10 Rated C
Rated
Applicable Standard JEC / IEC Protect
Withsta
Power Company 161kV 3 Rated Voltage [kV] 55 / 27.5 Rated S
Voltage
Curren
Type ONAN (Line to
27S1,27G1 27S2,27G2 Traction Transformer P10 Applica
Self Capacity [MVA] 4 / 5 / 7.5 / 10 Earth)
(Scott Connection) Rated
Roof-delta Connection Transformer P10
Power Line Capacity [MVA] Rated C
51S1,51G1 51S2,51G2 Example of Roof-delta 8 / 10 Transformer
Connection / 15 / 20
Overload
Rated Voltage [kV] 300%
55 2min
/ 27.5 Rated S
Utility Feeding System for High Speed Railway Current
Solid Insulated Type
Short Voltage
Circuit Intensity Can withstand thermally and mechanically
ONAN
Rated [kV] 220kV
for 25 /or60kV2
Auto-transformer
Switchgear 35 times of the rated current Applica
87T1,51T1,50GT1 87T2,51T2,50GT2 Rated Type Self Capacity [MVA] 4 / 5 / 7.5 / 10

4-2
51GT1 51GT2 Cooling
Applicable Standard ONAN
JEC / IEC
Power Line Capacity [MVA] 8 / 10 / 15 / 20
SF6 -Gas Insulated Rated Power [MVA] 60 P10
Switchgear (GIS) Overload
Overload 300%2min
300% 2min
Mtr1 Mtr2
Can withstand thermally and mechanically Rated V
Short
The Auto-transformer is used for the AT Feeding System (25kV 2) Circuit
Connection
which Intensitycatenary Roof-delta
reduces voltage drops
51B1M 51B1T 51B2M 51B2T
for 25 or 35 times and
of theelectro-magnetic
rated current Rated
Applicablethe
interference. It should be designed with low impedance and to withstand Standard JEC /current.
high short circuit IEC Withsta
50OT1T 50OT1M 50OT2T 50OT2T Applicable Standard JEC / IEC
Voltage
OT1 OT2
(Line to
51OT1 51OT2T Earth)
Ratings
P10 Rated C
Rated Voltage [kV] 55 / 27.5 Rated S
Current
Type ONAN
27.5kV VWA-Type Applica
21F41,50F41 21F11,50F11 21F13,50F13 21F12,50F12 21F14,50F14
Vacuum Switch Rated Self Capacity [MVA] 4 / 5 / 7.5 / 10
Power Line Capacity [MVA] 8 / 10 / 15 / 20
Overload 300% 2min
AT41 AT11 AT13 AT12 AT14
27F41M 27F11 27F13 27F12 27F14
Short Circuit Intensity Can withstand thermally and mechanically
for 25 or 35 times of the rated current
27F41W VS-A VS-B VS-A VS-B
Applicable Standard JEC / IEC
5

VS (Vacuum Switch)
Frequently Changeover
Capability
(over 200,000 times)
Control & Relay
Panel Overview
Auto-transformer
9 10
P11
P14
72.5 ~ 252
25 ~ 63
Feeding Circuit Breaker / Switchgear
Rated Voltage [kV]
Rated Bus Current [A]
36 / 72
1200 Cooling and Insulating Method Gas Mineral Oil
Feeding Circuit Breaker / Switchgear
Liquid Silicone Vegetable Oil Epoxy Resin
] 325 ~ 1050
140 ~ 460 4-3 (Solid Insulated Switchgear)
Rated Breaking Current [kA]

Rated Withstand Voltage


Lightning Impulse [kV]
16 / 25
200 / 350
Rated Power
Primary
4-4 (Gas Insulated Switchgear)
Applicable for up to 6MW Rectier
77kV 35kV
0.7(GCB) / 0.7(GIS) Power Frequency [kV] 70 / 140 Rated Voltage
Secondary Applicable for DC600V / 750V / 1500V / 3000V
JEC / IEC Rated Gas Pressure [MPaG] 0.05 (at 20C) Applicable Standard JEC / IEC
P6 P11
Toshiba developed a single-phase SIS for AC Feeding System. This next generation switchgear uses an improved insulation Dual
P14or single-pole circuit breakers are used for AC outgoing feeders. These must demonstrate a long operating life and have a reclosing
material in Voltage
Rated place of[kV]the conventional SF 6 gas which72.5 further
~ 252 enhances its functionality
Ratedand reliability.
Voltage [kV] Using epoxy resin material 36 / 72 function. Individual gas circuit breakers (GCB), gas insulated switchgears (GIS), or cubicle type gas insulated switchgears (C-GIS) are used.
P11 P14
for insulation also allows
Rated Interrupting both
Current [kA]installation even in harsh
25 ~ 63environment and drastic reduction in space
Rated Bus Current [A] requirement. Furthermore, 1200 Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
SIS hasRated
Rated a modular
[kV] composition
Lightning
Voltage 36 which
Impulse Withstand enables
Voltage [kV] easier325
replacement,
~ 1050 maintenance andRated
customization.
Breaking
Cooling Method Current [kA] Vertical heat-pipe self cooling 16 / 25 Rated Power Applicable for up to 6MW Rectier
GSM / GSP GSPF Rated Rated Power
Current [A] Frequency Withstand
1200 Voltage [kV] 140 ~ 460 Lightning Impulse [kV] 200 / 350
RatedWithstand
Rated Power Voltage ~ 6 MW Primary 77kV 35kV
72 / 84 / 168 145 Rated Gas Pressure 0.7(GCB) 70 / 140 Rated Voltage
Lightning Between Main Circuit and Earth 200 / 0.7(GIS) Rated Voltage Power Frequency [kV]
DC 600V / 750V / 1500V / 3000V Secondary Applicable for DC600V / 750V / 1500V / 3000V
Motor Spring Motor Spring Rated Applicable
Impulse [kV]
Standards JEC250
Between Main Circuit Terminals / IEC Rated Gas Pressure [MPaG] 0.05 (at 20C)
Withstand Applicable Standard
Operation JEC / IEC Applicable Standard JEC / IEC
Tank Live Tank Power Between Main Circuit and Earth 70 1min.
Voltage mechanism VDS
Frequency [kV] Between Main Circuit Terminals 100 10min.
350 / 400 / 750 650 Bus
P11 P14
Rated Short Time Withstand
P7 12.5 2sec.
140 / 160 / 325 275 Current [kA] Rated Voltage [kV] 36 Cooling Method Vertical heat-pipe self cooling
Mechanical GSR GSM / GSP
200,000 times GSPF Rated Current [A] 1200
JEC / IEC Rated Power ~ 6 MW
Switching
RatedLifetime
Voltage [kV] 240 / 300
Electrical 100,000 times / 84 / 168
72 145
Lightning Between Main Circuit and Earth 200 Rated Voltage DC 600V / 750V / 1500V / 3000V
Method of Operation Hydraulic Motor Spring Motor Spring Rated Impulse [kV] Between Main Circuit Terminals 250
Withstand Applicable Standard JEC / IEC
Tank Dead Tank Live Tank Between Main
Voltage Power ESCircuit and Earth 70 1min.
Lighting Frequency [kV] Between Main Circuit Terminals 100 10min.
Rated 900 / 1050 350 / 400 / 750 650 C-GIS for AC Traction Circuit GIS for AC Traction Circuit GCB for AC Traction Circuit
Impulse [kV]
P17 Withstand P15
Rated Short Time Withstand
Voltage Power 200-265-200(1min)/ 12.5 2sec.
140 / 160 / 325 275 Current [kA]
36 40.5 72 84 Frequency [kV] 250-330-250(1min)

1700
Rated Voltage [V] DC 750 , 1500
170 185 350 400 Applicable Standards
Rated Current [A] 3000 , 4000
JEC / IEC P6 Lifetime
Switching
Mechanical
VCB 200,000 times
Ratings (C-GIS)
P11
1,000kWcontinuous rating
Electrical 100,000Inverter
Regenerating times mode P14
70 95 140 160 Rated Breaking Capacity [kA] 50 (at 310 A / sec), 100 (at 1010 A / sec)
6 6 Capacity
Rated Voltage [kV] 72.5 ~ 252
3,000kW1minute or 4,500kW-30seconds
Rated Voltage [kV] 36 / 72 Features Compact Design
250 / 1250 / Rated Short Time Current [kA] 50-1sec , 100-1sec Powering Converter mode 1,000kWcontinuous rating only
0 2000
800 / 1250 Rated Interrupting Current [kA] 25 ~ 63
CT
Rated Bus Current [A] 1200 Cooling and
Outdoor Compatibility Gas
Insulating Method Mineral Oi
Applicable Standard JIS (To be developed for IEC) Rated Lightning Impulse Withstand
1,500VDC Voltage [kV] 325 ~ 1050 Rated Breaking Current [kA] 16 / 25
P8 Rated Power A
25 / 31.5 RatedRated
P17 Input Voltage OutputVoltage
Power Frequency Withstand control [kV]
mode (Make 140 a selection
~ 460 for your operation ) P15 Lightning Impulse [kV] 200 / 350 Safe Operation
Primary
-1) Load control: To 6 or 8 output regulation Rated Withstand Voltage
Rated Gas Pressure 0.7(GCB) / 0.7(GIS) Power Frequency [kV] 70 / 140 Rated Voltage
JEC / IEC / GB Rated Voltage [kV] 24 36 40.5 15
00
72 84
Rated Voltage [V] Standards
-2) Constant voltage control
DC 750 , 1500 Low Maintenance
Secondary Appli
Applicable JEC / IEC Rated Gas Pressure [MPaG] 0.05 (at 20C) Applicable Standard
Rated Lightning Impulse [kV] 125 170 185 350 400 RatedCurrent
Output[A]Voltage 1,200VAC 1,000kWcontinuous rating
Rated 3000 , 4000
P17 Withstand 600 Regenerating Inverter mode
Voltage Power Frequency [kV] 50 70 95 140 160 Rated Capacity [kA] 50 1Series
(at 310*6A2Parallel * 6Arm
/ sec), 100 * 2Bridge
(at 1010 6A / sec) Capacity 3,000kW1minute or 4,500kW-30seconds
Main Breaking
Circuit Configuration
Specifications Applicable equipments Double bridge parallel configuration by Transformer P11 Powering Converter mode 1,000kWcontinuous ratingP14
only
630 / 1250 / 1250 / Rated Short Time Current [kA] 50-1sec , 100-1sec
Rated Current [A] SIS 800 / 1250 Device
P7 IGBT (3,300V-1,200A)
27.5kV
MV Switchgear Unit 7.2 / 24 / 36kV 2000
Air Insulated 2000
type or Cross Section Applicable Standard Side
JISView
(To be developed for/ IEC)
MG1200FXF1US53(P)
Solid Insulated type Device Cooling System Heat-pipe in pure water (natural cooling type) Rated Voltage [kV] 361,500VDC Cooling Method Vertical heat-pipe self cooling
Rated Short Time Withstand GSR GSM / GSP GSPF Output control mode (Make a selection for your operation )
25 / 31.5 Rated Current
Rated Input Voltage
[A] 1200 Rated Power
Current [kA] TR : Epoxy Resin Molded Dry Inverter-2,700W * 2,200D * 2,900H -1) Load control: To 6 or 8 output regulation ~ 6 MW

Single Phase Vacuum Circuit Breaker


Rated Voltage [kV] 240 / 300 72 / 84 / 168 145 Lightning -2) Constant
Between Mainvoltage control
Circuit and Earth 200
Applicable
12-Pulse Unit Up to 2,000kW
RectifierStandard / Liquid
JECSilicone
/ IEC / GB Dimension Control Panel of Inverter-800W * 1,000D * 2,300H Rated Voltage DC 600V / 750V / 1500V / 3000V
Single Line Diagram
DC Switchgear Unit DC 600V, DC1500V
SR : Heat-pipe Self-cooling

HSCB or HSVCB
Method of Operation
P17 Tank
Hydraulic
Dead Tank
Motor Spring Motor Spring
DC Reacrtor-2,800W * 2,000D * 2,500H
Live Tank 4-5 Rated
Withstand
Impulse [kV]
Rated Output Voltage
Voltage Power
Between Main Circuit Terminals 250
1,200VAC
Between Main Circuit and Earth 70 1min.
1Series * 2Parallel * 6Arm * 2Bridge
Applicable Standard JEC / IEC

Lighting Frequency [kV]


Main Circuit Configuration Between
2-Phase
Auxiliary AC27.5kV
Power DC 110V, Rated 900 / 1050 Applicable
Specifications 350 / 400 / 750
equipments 650 Double Main
bridgeCircuit Terminals
parallel 100 10min.
configuration by Transformer
m for High Speed Railway Lead Storage Battery Impulse [kV] Toshiba's VCB designed for 27.5kV single phase AC feeding system uses high performance vacuum switches that are able to
Supply Unit AC 105V / 210V Withstand Rated
DeviceShort Time Withstand IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
Air Insulated type or
Power 7.2 / 24 /200-265-200(1min)/ withstand 12.5 2sec.
61 / 60x 2 ; 132 / 27.5x 2 GPS
P7 Voltage Unit
MV Switchgear 36kV 140 / 160type
Solid Insulated / 325 275 Current [kA]high voltages and extensive switching cycles.
Antennae Frequency [kV] 250-330-250(1min) Device Cooling System Heat-pipe in pure water (natural cooling type)
/ OFAF
Applicable Standards JECResin
/ IEC Molded Dry Mechanical 200,000
Inverter-2,700W times * 2,900H
* 2,200D
Remote Terminal Unit Rated Voltage [kV] TR : Epoxy 36 40.5 Switching Lifetime
72 84
12-Pulse Rectifier Unit Up to 2,000kW / Liquid Silicone Dimension Electrical 100,000
Control Panel times
of Inverter-800W * 1,000D * 2,300H
Lightning Impulse [kV]
SR : Heat-pipe 170
Self-cooling 185 350 400
P13 Rated Withstand Voltage DC Reacrtor-2,800W * 2,000D * 2,500H
Control/Status Signal
Power Frequency [kV] 70 95 140 160
P10
21F Distance Protection
Control Display Current Input
DMS
DC Switchgear Unit
Rated Current [A]PC
SW-HUB
DC 600V, DC1500V HSCB or HSVCB
630, 1250, 2500 630, 1250, 2000 800, 1250 800, 1250 Features High Voltage Withstand

Voltage Input
Application 51F Overcurrent
FIFeeding SystemProtection
for High Speed Railway Rated P8Short
Auxiliary Power DC 110V,
Time Withstand Current [kA] 25, 31.5
Lead Storage Battery 25, 31.5 20, 25, 31.5 20, 25, 31.5
P15
Capability
Protection Function
Voltage
Supply Unit AC 105V / 210V P17 This vacuum circuit breaker
Rated Voltage [kV] 27F 220 / 25x 2Protection
; 161 / 60x 2 ; 132 / 27.5x 2 Applicable Standards JEC / IEC
Receiving,Feeding Rated Voltage [kV] 24 36 40.5 72 84 P7 can be supplied as a In order to withstand the
Cooling Type 79 Automatic
ONAN / ONAFReclose
/ OFAF Digital Digital Rated Voltage [V] DC 750 , 1500
AT Distribution Line Relay(G2) Relay(G2)
Rated Lightning Impulse [kV]VT Panel
125 170 185 350 400 withdrawable trolley type excessive voltage at the phase
VT Panel
Rated Power [MVA] Feeder
LocatorPanel 84 / 60 Incoming Panel Bus Tie Panel System 1 Incoming Panel
System 2 Feeder Panel Rated Voltage [kV]
Current [A] 3000 , 4000 36 40.5 72 84 1,000
Interlock Circuit Withstand VCB6 or as a fixed installation. Capacity
break point, two vacuum
Regenerating Inverter mode
ormer Overload 200% 5mins(Relay Sequence) Voltage Power Frequency [kV] 50 70 95 140 160 Rated Breaking Capacity [kA]Lightning Impulse
50 (at 310 [kV] 100 (at 1010170
A / sec), A / sec)
6 185 350 400 3,000
P13 Rated Withstand Voltage interrupters are provided in series
Connection SWScott 630 / 1250 / 1250 / Power
Rated Short Time Current [kA] Frequency
50-1sec [kV]
, 100-1sec 70 95 140 Powering
160 Converter mode 1,000
m for High Speed Railway Trip,Reclose, Rated Current [A] 21F Distance Protection 800 / 1250 for the switch.
Applicable Standard JEC / IEC Fault display 2000 2000 Rated Current
Applicable [A]
Standard 630, 1250, 2500
JIS (To be developed for IEC) 630, 1250, 2000 800, 1250 800, 1250
2 1,500VDC
Clamp 51F
Rated Short Time Withstand Overcurrent Protection P7Rated Short Time Withstand Current [kA] 25, 31.5 25, 31.5 20,Voltage
25, 31.5 20, 25,control
Output 31.5 mode (Make a selection for yo
25 / 31.5 Rated Input
JEC / IEC Long Life Operation
CT Protection
P12 Function
Current [kA] 27F Voltage Protection -1) Load control: To 6 or 8 output regulati
Ratings
P10
Applicable Standards 27.5kV Vacuum Circuit Breaker
-2) Constant voltage control
RatedApplicable Standard 79 JEC27.5
/ IEC / GB Rated Voltage [kV] 36 40.5 72 84
Control Display I
Voltage [kV] Automatic Reclose Aiming at long life operation,
P10
Rated Voltage [kV] 27.5 FeaturesRated Current
SF6[A]gas-less due to epoxy- 1250
Rated Lightning Impulse [kV] 170 185 350 400 Rated Output
a simple 1,200VAC
Voltageelectro-magnetic
Main Circuit P17
Withstand
ExampleLightning
Rated 200 (to earth and across
of Roof-delta Connection Transformer open contacts)
Equipment V resin coatingLightning Impulse [kV] 250 Voltage Power Frequency [kV] 70 95 140 160 operation
Main Circuit
1Series
mechanism
Configuration is*used.
2Parallel * 6Arm * 2Bridge
Withstand Impulse [kV] 220 (across isolating distance) Rated Withstand Voltage Specifications Applicable equipments Double bridge parallel configuration by Trans
Power Frequency [kV] 95 630 / 630 /
VoltageUtility Feeding System for High Speed Railway Compact Design Rated Current [A] 1250 / 1250Air
800 /
/ Insulated
800 /
Device IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
(Line to Power
Rated Voltage [kV]
95 (to earth and across open contacts)
220kV / 60kV2
Rated Short Time Withstand Current [kA] 25 MV Switchgear Unit 7.2 / 24 / 36kV 1250 type or
1250
Frequency [kV] 110 (across isolating distance) 2500 2000Solid Insulated type Device Cooling System
Earth)
Cooling Type ONAN Outdoor Compatibility Ratings
P12
Rated Withstand
Short Time 25 / 25 / 20 / 25 / 20 / 25 /
P7
Heat-pipe in pure water (natural cooling type
Rated Current [A] 1250 Inverter-2,700W * 2,200D * 2,900H
Current [kA] 31.5 31.5TR : Epoxy
31.5Resin Molded
31.5 Dry
Rated Power [MVA]
Rated Overload
Short Time Withstand
60 P10 Safe Operation 12-Pulse
Rated Rectifier
Voltage [kV]Unit Up to 2,000kW / Liquid 27.5
Silicone Dimension
Rated Voltage [kV] 36
Control 40.5 of Inverter-800W
Panel 72 84
* 1,000D * 2,30
31.5 300% 2min Applicable Standards JEC
SR :/Heat-pipe
IEC Self-cooling
Current [kA] Rated Lightning Impulse [kV] DC
170Reacrtor-2,800W
185 * 2,000D *400
350 2,500H
Connection Roof-delta P10
Low Maintenance
Rated Voltage [kV] 27.5 Rated Current [A] 1250
Withstand
Applicable Standard IEC Rated Lightning 200 (to earth and across open contacts) DC Switchgear Unit DC 600V, DC1500V
Lightning Impulse HSCB
[kV] or HSVCB 250 Voltage Power Frequency [kV] 70 95 140 160
Applicable Standard JEC / IEC Withstand High Reliability
Impulse [kV] 220 (across isolating distance) Rated Withstand Voltage
Auxiliary Power DC 110V,
Power Frequency [kV] 95Battery
0 VoltageApplication Feeding System for High Speed Railway
Supply Unit AC 105V / 210V
Lead Storage 630 / 630 / 800 / 800 /
Power [kV]
(Line toRated Voltage 95 (to earth
220 /and
25x across
2 ; 161open
/ 60x contacts)
2 ; 132 / 27.5x 2 Rated Short Time Withstand Current [kA] 25 Rated Current [A] 1250 / 1250 / 1250 1250
Frequency [kV] 110 (across isolating distance) P7 2500 2000
Earth)
d thermally and mechanically Cooling Type ONAN / ONAF / OFAF
mes of the rated current 11 12
P10 Rated Short Time Withstand 25 / 25 / 20 / 25 / 20 / 25 /
Rated Current [A] [MVA]
Rated Power 1250 84 / 60 CurrentRated
[kA] Voltage [kV] 31.5 31.5 31.5 36
31.5
Rated Voltage [kV] 55 / 27.5 Rated Short Time Withstand
Overload 31.5 200% 5mins Applicable Standards Lightning ImpulseJEC
[kV]/ IEC 170
Current [kA] P13 Rated Withstand Voltage
Type ONAN Connection Scott Power Frequency [kV] 70
Self Capacity [MVA] 4 / 5 / 7.5 / 10 Applicable Standard
Applicable Standard IEC JEC / IEC 21F Distance Protection Rated Current [A] 630, 1250, 2500
Rated
Power Line Capacity [MVA] 8 / 10 / 15 / 20 51F Overcurrent Protection Rated Short Time Withstand Current [kA] 25, 31.5
Protection Function
P13 P8

Changeover Switch 4-8 Control / Relay


The Greenhouse Eect Panel
4-6 Sun
P11 P15
Single pole vacuum switches (VS) are used for power switching at phase break points for AC high speed railway systems. Toshiba The integrated control and relay panels are provided for AC feeding substations. They are designed with the advanced digital
is a leading company in manufacturing changeover switches equipment for railways. technology and consist of elements such as a digital protection relay, programmable logic controller (PLC), colored LCD touch
A tconnection.
screen, Ethernet LAN mo
Green sph
h ous er
substation substation e Ga
e Power Source

se
s
21F 50F Features Colored LCD Touch Screen
P11
Power supply ranges 100 - 250Vdc
Sectioning Post Transformer for Human Interface
IEC60870-5-103 / Inputs / outputs Digital input 18*
P14
VS-A VS-B
Earth
0 etc.
72.5 ~ 252 Rated Voltage [kV]
Digital output 18*
36 / 72 Redundant System
25 ~ 63 Rated Bus Current [A] 1200 IGBT
panese / Portuguese
] 325 ~ 1050 Rated Breaking Current [kA]
Analog input 4*
16 / 25
Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin Regenerative
Inverter
Self-monitoring
Escalator and Self-
Lighting
Rated Power Applicable for up to 6MW Rectier
140 ~ 460
Communication ModbusImpulse
Lightning / IEC61850
[kV]/ IEC60870-5-103
200 / 350 / Primary 77kV 35kV
diagnosis Function
protocol & Interface
Rated Withstand Voltage Web browser DNP3.0 etc. Traction Substation Passenger Station Facility
0.7(GCB) / 0.7(GIS) Power Frequency [kV] 70 / 140 Rated Voltage
tection Changeover Switch[MPaG] Relay W205D187.8H255.9
Changeover0.05
Switch in Cubicle
Secondary
Application of Changeover Switch
Applicable for DC600V / 750V / 1500V / 3000V Alarms and Commands
JEC / IEC Rated Gas Pressure
Dimensions (at 20C)
e of rise protection MIMIC W149D 23.8H278.5 Applicable Standard JEC / IEC Logs Function
t protection (4 stages) LCD language English / Chinese / Japanese / Portuguese
erload protection (3 stages) Ratings
P11
Measuring Data (voltage,
*Maximum value P14
e protection (2 stages) current, power, power factor
Rated Voltage [kV] 36 FeaturesCooling Method
High Voltage Withstand Decelerating / Regeneration by Brake Accelerating / Powering
ge protection (2 stages) I Current surge protection Vertical heat-pipe self cooling etc.)
GSM / GSP
osing function
GSPF Rated Current [A] 1200
di / dt Current rate of rise protection
Rated PowerCapability ~ 6 MW
72 / 84 / 168 145
Lightning Between
50 Main Circuitprotection
Overcurrent and Earth (4
200
stages) In order to withstand
Rated Voltage the excessive
DC 600V voltage
/ 750V / 1500V / 3000V Connection with Remote
Motor Spring Motor Spring Protection Function
Rated at the phase break point, two vacuum
Impulse [kV]
Control Center (SCADA)

1700
Between
49 Main Circuit
Thermal Terminals
overload 250(2 stages)
protection Applicable Standard JEC / IEC
n* Withstand interrupters are provided in series for the
Tank Live Tank
SWGR, CB) Voltage Power Between
59 Main Circuitprotection
Overvoltage and Earth (3
70stages)
1min. P9
switch.
Frequency [kV] Between Main Circuit Terminals
n 350 / 400 / 750
fuction 650 27 Undervoltage protection100 10min.
(3 stages)
Rated Short Time Withstand Multi-shots
Long Life Operation
edance 12.5 2sec. auto-reclosing function 21F 50F
140 / 160 / 325 275 Current [kA] Aiming for long life operation, a simple
Line test Function
Controll Function electro-magnetic operation mechanism is
n JEC / IEC Switching Lifetime
Mechanical
Interbreaking200,000 times
Function** used. Control/Relay Panel P13
Electrical
Controlling100,000 times
Function(SWGR, CB)
ng 15
00
Metering Function I, V, +Wh, -Wh, Impedance
TO POWER COMPANY 3 phase NETWORK
CB state condition
600
Trip circuit supervision Substation Monitoring System
Power Company 161kV 3
P15
P17 Trip counter monitoring
Monitoring Function This Control/Relay Panel for AC Receiving Substations is installed with G2 Relay and monitoring system that utilizes DMS (Digital
36 40.5 72 84 CB operate time

AC Feeding Protection Relay(GRY-200 Series)


27S1,27G1 27S2,27G2
Rated Voltage [V] DC 750 , 1500 21F 50F Monitoring System). Hence, it can flexiblydeal with both distributed and clustered systems. G2 Relays features include fault

4-7
170 185 350 400 I alarm
Rated Current [A] 3000 , 4000 1,000kWcontinuous rating
waveform collection, transmission functions and a user-friendly LCD interface.
Self supervision 51S1,51G1 Regenerating Inverter mode
51S2,51G2
n 70
the substations
95 are required.
140 160 Rated Breaking Capacity [kA] 50 (at 3106A / sec), 100 (at 1010 6A / sec) Capacity 3,000kW1minute or 4,500kW-30seconds
System monitoring results such as daily and monthly energy status reports and fault history can be displayed through its
Event records Powering Converter mode 1,000kWcontinuous rating only LCD.
250 / 1250 / Rated Short Time Current [kA] 50-1sec , 100-1sec large
800 / 1250 Record Function Fault records relay provides mainly 2
0 2000 Toshibas AC feeding
Applicable Standard protection
JIS (To be developed for IEC) 21F 87T1,51T1,50GT1 50F 87T2,51T2,50GT2 21F 50F
Disturbancevent records Load current with 51GT1 51GT2 1,500VDC Load current with
25 / 31.5
protection functions called Distance Relay (21F), and Thyristor Controlled
Rated InputCarsVoltage Output control mode (Make a selection for your operation ) Thyristor Controlled Cars
Instantaneous Overcurrent Relay
*Communication line (50F).
betweenIfthe
failure is detected,
substation is requieredit -1) Load control: To 6 or 8 output regulation
m)

m)
Angle

Angle
Mtr1 Mtr2
10 nt

10 nt
-2) Constant voltage control
ce rre

ce rre
JEC / IEC / GB
oh

oh
will isolate failure circuit quickly. X X
tan Cu

tan Cu
GPS
g Line

g Line
sis ult

sis ult
X1 Antennae X1
Rated
51B1MOutput Voltage
51B1T 51B2M 1,200VAC
51B2T
Re Fa

Re Fa
Zone1 Zone1
P17
ult um

ult um
Feedin

Feedin
50OT1T 50OT1M 50OT2T 50OT2T
Detected
1Series Rise Current(Ifv)
* 2Parallel * 6Arm * 2Bridge Detected Rise Current
(Fa inim

(Fa inim
Main
When aCircuit Configuration Remote Terminal Unit
OT1 X2 train
Double bridge parallelOT2
on 50F
configuration by Transformer
X2 When a train on 50F
Specifications Applicable equipments
M

M
Zone2 comes, Ifv=(If 2+IL 22If Zone2 comes, Ifv=(If 2+IL 22If
impedance ILcoslf~IL) impedance ILcoslf~IL)
Air Insulated type or
51OT1
Device
zone changes IGBT (3,300V-1,200A) 51OT2T
/ MG1200FXF1US53(P) zone changes
If

If
urrent Control/Status Signal Curren
MV Switchgear Unit 7.2 / 24 / 36kV um Load
C
um Load
Ratings
P13
Solid Insulated type Device Cooling System IL
Maxim in pure water (natural cooling type)
Heat-pipe Control Display Current Input
DMS SW-HUB PC
IL
Maxim

TR : Epoxy Resin Molded Dry Failure


Load current of PWM
Inverter-2,700W * 2,200D * 2,900H Voltage Input Failure
Load current of PWM
Zone FI Zone
DC900 / 1800 12-Pulse Rectifier Unit 21F Distance Protection/ Liquid Silicone
Up to 2,000kW Dimension
Controlled Cars Control Panel of Inverter-800W * 1,000D * 2,300H Controlled Cars

4000 ~ 12000 51F SR : Heat-pipe Self-cooling


Overcurrent Protection 21F41,50F41 R2 R121F11,50F11 R 21F13,50F13 21F12,50F12 21F14,50F14 R2 R1 R
DC Reacrtor-2,800W * 2,000D * 2,500H
The Greenhouse Eect
Receiving,Feeding Digital Digital
t [kA] 80 Protection Function 27F Voltage
DC 600V, Protection
DC1500V HSCB or HSVCB
DC Switchgear Unit AT Distribution Line Relay(G2) Relay(G2)
Locator
Automatic Reclose System 1 System 2
Sun
[kV] 20 79 Interlock Circuit
m for High Speed Railway
kV] 9.2
Auxiliary Power DC 110V,
50F Instantaneous Lead Storage
Overcurrent Battery AT41
Protection 27F41M
AT11
27F11
AT13
27F13
AT12
27F12
AT14
27F14 (Relay Sequence)
Supply Unit AC 105V / 210V
61 / 60x 2 ; 132 / 27.5x 2
JIS / IEC Multi-shots auto-reclosing function 27F41W P7
VS-A VS-B VS-A VS-B
SW
/ OFAF Trip,Reclose,
Control Function Inter breaking function * 5 Fault display

Controlling function (SWGR, CB) FeaturesRated Voltage


Compact
[kV] Design 36 40.5 72 84 Clamp
Lightning Impulse [kV] 170 185 350 400 CT
P13
Metering Function I, V, W, +Wh, Impedance
Event records
Colored
Rated Withstand LCD touch
Voltage screen for
Power Frequency [kV] 70 95 Atmosphere
140 160
Control Display I
21F Distance Protection human interface
Monitoring Function Fault records
Rated Current [A] 630, 1250, 2500 630, 1250, 2000 Greenhouse Gases
800, 1250 800, 1250
51F Overcurrent Protection Flexible
Rated Short Installation
Time Withstand Current [kA] 25, 31.5 25, 31.5 20, 25, 31.5 Main Circuit20, 25, 31.5
Protection Function Disturbance records Equipment V
27F Voltage Protection Applicable(The touch panel and the main
Standards JEC / IEC
CB and DS status
79 Automatic Reclose
CB and DS response monitoring unit are separated.)
Earth
Record Function Trip circuit supervision Support a wide range of
ormer Trip counter monitoring categorized by breaking level communication protocol
m for High Speed Railway Self-supervision LCD panel (31.5 inch)
2 *Communication lines between the substations are required.
13 P12 P7 14
P10 Rated Voltage [kV]
Rated Voltage [kV] 27.5 36 40.5 72 84
Rated Voltage [kV] 27.5 Rated Lightning Impulse [kV] 170 185 350 400
Rated Current [A] 1250
Withstand
Rated Lightning 200 (to earth and across open contacts) Lightning Impulse [kV] 250 Voltage Power Frequency [kV] 70 95 140 160
Withstand Impulse [kV] 220 (across isolating distance) Rated Withstand Voltage
Power Frequency [kV] 95 630 / 630 /
5 DC Electrification Systems
5-1 Rectifier Transformer
Toshiba also provides a highly-reliable and modernized DC electrification system. In addition to
conventional equipment like rectifier transformers, rectifiers, and high speed circuit breaker (HSCB), a lot
of new equipment has been developed with power electronics and digital technology. Toshiba presents
P15
innovative solutions to meet customers needs.

Power Source
Features For better environmental friendliness, a liquid silicone transformer or vegetable oil transformer can
be used for the rectifier transformer.
Heat pipe Rectifier has a very high thermal efficiency and can be installed outdoors. Gas Insulated Transformer Liquid Silicone Transformer Epoxy Resin Molded Dry Transformer

Transformer High Speed Vacuum Circuit Breaker (HSVCB) has high reliability, safety and can reduce
maintenance
Regenerative Inverter is a good energy saving solution for the efficient use of regenerative braking Features Nonflammable SF6 Gas Insulated
IGBT
Regenerative power from Escalator
rolling stocks.
Lighting Transformer is suitable for indoor use.
Inverter
SCiB Traction Energy Storage System is an energy saving solution which is not only useful Noncombustible liquid silicone
Traction Substationfor storage of Passenger Station Facility
regenerative energy but also for promoting power peak cut, feeder voltage transformer and vegetable
compensation and emergency power supply. oil transformer are friendly to
environment.
Package Type Substation saves space and construction works.
Vegetable Oil Transformer

P6 P11
P14
TOSHIBA's POWER SUPPLY SYSTEMS
Decelerating / Regeneration by Brake
Rated Voltage [kV]
for DC Feeding Substation Rated Voltage [kV]
Accelerating / Powering
72.5 ~ 252 36 / 72 Ratings
Rated Interrupting Current [kA] 25 ~ 63 Rated Bus Current [A] 1200 Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
Rated Lightning Impulse Withstand Voltage [kV] 325 ~ 1050 Rated Breaking Current [kA] 16 / 25 Rated Power Applicable for up to 6MW Rectier
Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Lightning Impulse [kV] 200 / 350
Rated Withstand Voltage Primary 77kV 35kV
Rated Gas Pressure 0.7(GCB) / 0.7(GIS) Power Frequency [kV] 70 / 140 Rated Voltage
Secondary Applicable for DC600V / 750V / 1500V / 3000V
Applicable Standards JEC / IEC Rated Gas Pressure [MPaG] 0.05 (at 20C) Applicable Standard JEC / IEC

Regenerative Inverter Heat-pipe cooled Silicon Rectifier SF6 -Gas Insulated Switchgear(GIS) P11 P14
P6 P11
P7
P13 Power Transformer SF6 -Gas Insulated P14

Traction Rectifier
Rated(Oil
Voltage [kV]
immersed) 36
Transformer Cooling Method Vertical heat-pipe self cooling
Rated Voltage [kV] 72.5 ~ 252 Rated Voltage [kV] 36 / 72

5-2
GSR GSM / GSP GSPF Rated Current [A] 1200
Rated Interrupting Current [kA] 25 ~ 63 Rated Bus Current [A] 1200 Rated Power ~ 6 MW
Rated Voltage [kV] 240 / 300 72 / 84 / 168 145 Between Main Circuit and Earth 200 Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
TO POWER
Rated Lightning Impulse COMPANY 3 phase
Withstand Voltage [kV]NETWORK 325 ~ 1050 Rated Breaking Lightning
Current [kA] 16 / 25 Rated Voltage DC 600V / 750V / 1500V / 3000V
Method of Operation Hydraulic Motor Spring Motor Spring Rated Impulse [kV] Between Main Circuit Terminals 250 Rated Power Applicable for up to 6MW Rectier
Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Withstand Lightning Impulse [kV] 200 / 350 Applicable Standard JEC / IEC
Tank Dead Tank Live Tank Rated Withstand Voltage Primary 77kV 35kV
Rated Gas Pressure 0.7(GCB) / 0.7(GIS) Voltage Power Between Main Circuit and Earth 70 1min.
Power Frequency [kV] 70 / 140 Toshiba has a long history of manufacturing rectifiers
Rated Voltage (diode, thyristor, and IGBT type). Our current Rectifier has a heat pipe cooling
Lighting Frequency [kV] Between Main Circuit Terminals 100 10min. Secondary Applicable for DC600V / 750V / 1500V / 3000V
Rated
Applicable Standards
Impulse [kV]
900 / 1050 350 / 400 / 750
JEC / IEC 650 Rated Gas Pressure [MPaG] 0.05 (at 20C) system using high purity water. It is suitable for repeated overload current and has large cooling capacity and it can be installed outdoor.
Withstand Applicable Standard JEC / IEC
Rated Short Time Withstand 12.5 2sec.
Voltage Power 200-265-200(1min)/
140 / 160 / 325 275 Current [kA] Traction Energy Storage System (TESS)
Frequency [kV] 250-330-250(1min)
Applicable Standards JEC / IEC P11
Switching Lifetime
Mechanical 200,000 times Ratings
P14
P7 Electrical 100,000 times
Rated Voltage [kV] 36 Cooling Method Vertical heat-pipe self cooling
GSR GSM / GSP GSPF
P14~
Rated Current [A] 1200 Rated Power 6 MW
Rated Voltage [kV] 240 / 300 72 / 84 / 168 145 Lightning Between Main Circuit and Earth 200 Rated Voltage DC 600V / 750V / 1500V / 3000V
P8Method of Operation Hydraulic Motor Spring Motor Spring Rated Impulse [kV] Between Main Circuit Terminals 250
Withstand Applicable Standard JEC / IEC
Tank Dead Tank Live Tank P17 P15
Voltage Cubicle type SFBetween
Power 6 -Gas Insulated
Main Circuit and Earth 70 1min.
Rated Voltage [kV]
Lighting 24 36 40.5 72 84 Switchgear(C-GIS)
Frequency [kV] Between Main Circuit Terminals 100 10min.
Rated 900 / 1050 350 / 400 / 750 650 Rated Voltage [V] DC 750 , 1500
Rated Impulse [kV]
Withstand Lightning Impulse [kV] 125 170 185 350 400 Heat 1,000kWcontinuous rating
Current
Rated Short [A] Withstand
Time 3000, 2sec.
4000
Withstand Power
Voltage 200-265-200(1min)/
140
12.5 Theory of Heat Pipe Cooling
Regenerating Inverter mode Radiation
70 / 16095
/ 325 140 275160

Condensation
Power Frequency
Voltage Frequency [kV] 50 Current [kA]
Rated Breaking Capacity [kA] 50 (at 3106A / sec), 100 (at 1010 6A / sec) Capacity 3,000kW1minute or 4,500kW-30seconds
[kV] 250-330-250(1min) Fin
Applicable Standards JEC/ / IEC
630 / 1250 1250 / Rated Short
Switching Time Current [kA] Mechanical
Lifetime
200,000 times
50-1sec , 100-1sec Powering Converter mode 1,000kWcontinuous rating only
Rated Current [A] 800 / 1250 Heat radiation
2000 2000 Applicable Standard Electrical
JIS (To be100,000 times
developed for IEC) => condensation 1,500VDC

Condensation
Rated Short Time Withstand Output control mode (Make a selection for your operation )
25 / 31.5 Rated Input Voltage Maintenance Ene
Current [kA] Heat convection by -1) Load control: To 6 or 8 output regulation PC Manage
-2) Constant voltage control

Vapor Flow
Applicable Standard JEC / IEC / GB Solid Insulated 24kV Metal-clad pressure difference
P8

Liquid Flow

Liquid Flow
Switchgear(SIS) Switchgear P15
P17 Rated Output Voltage 1,200VAC
P17 Pressure rise by
Rated Voltage [kV] 24 36 40.5 72 84 evaporation 1Series * 2Parallel * 6Arm * 2Bridge
Rated Voltage [V] DC 750 , 1500 Main Circuit Configuration
Specifications Applicable equipments Double bridge parallel configuration by Transformer
Evaporate
Rated Lightning Impulse [kV] 125 170 185 350 400 1,000kWcontinuous rating
Rated Current [A] 3000 , 4000 Device IGBT (3,300V-1,200A) / MG1200FXF1US53(P) System LAN-A(HUB)
Withstand MV Switchgear Unit Air Insulated type or Regenerating Inverter mode
7.2 / 24 / 36kV Capacity Coolant evaporation by
Voltage Power Frequency [kV] 50 70 95 140 160 Rated Breaking Capacity [kA] 50 (at 3106A / sec),
Solid100 (at 1010
Insulated 6A / sec)
type Device Cooling System
heat Heat-pipe in pure water (natural cooling3,000kW1minute
type) or 4,500kW-30seconds
System LAN-B(HUB)
Rated Short Time Current [kA] 50-1sec , 100-1sec Powering Converter mode 1,000kWcontinuous rating only

Evaporation
630 / 1250 / 1250 / TR : Epoxy Resin Molded Dry Inverter-2,700W * 2,200D * 2,900H
Rated Current [A] 800 / 1250 High Purity
2000 2000 Applicable Standard JIS (To be developed/ for IEC)Silicone Dimension Coolant and element

Heat
12-Pulse Rectifier Unit Up to 2,000kW Liquid Control Panel
1,500VDC of Inverter-800W * 1,000D * 2,300H
Water
SR : Heat-pipe Self-cooling heat exchange Base Clock Main S
Rated Short Time Withstand Output control mode*(Make
DC Reacrtor-2,800W 2,000Da *selection
2,500H for your operation )
25 / 31.5 Rated Input Voltage
Current [kA] -1) Load control: To 6 or 8 output regulation
P10 DC Switchgear Unit DC 600V, DC1500V HSCB or HSVCB
Applicable -2) Constant voltage control
MV/LV Metal-clad SF6Standard
-Gas Insulated JEC / IEC / GB
Liquid Silicone Transformer DC Switchgear DC Switchgear (HSVCB)
Switchgear Application
Transformer Feeding System for High Speed Railway Auxiliary Power DC 110V,
Supply Unit AC 105V / 210V
Lead Storage Battery Rated Output Voltage 1,200VAC Principle of Heat-pipe Self Cooling Heat-pipe Rectifier
Rated Voltage [kV] 220 / 25x 2 ; 161 / 60x 2 ; 132 / 27.5x 2 P17
15 P7
Main Circuit Configuration
1Series * 2Parallel * 6Arm * 2Bridge 16 PS LAN-A(HUB)
Cooling Type ONAN / ONAF / OFAF Specifications Applicable equipments Double bridge parallel configuration by Transformer
Rated Power [MVA] 84 / 60 Rated Voltage [kV]
Device 36
IGBT (3,300V-1,200A) / MG1200FXF1US53(P) 40.5 72 84 PS LAN-B(HUB)
MV Switchgear Unit 7.2 / 24 / 36kV Air Insulated type or
Overload 200% 5mins Solid Insulated type Device Cooling System Lightning Impulse
Heat-pipe [kV] water (natural
in pure 170cooling type) 185 350 400
P13 Rated Withstand Voltage
Connection Scott PowerInverter-2,700W
Frequency [kV]* 2,200D * 2,900H70 95 140 160
TR : Epoxy Resin Molded Dry
Applicable Standard JEC / IEC 12-Pulse Rectifier Unit Up21F
to 2,000kW Distance Protection
/ Liquid Silicone Rated Current [A]
Dimension 630, 1250,
Control Panel of Inverter-800W 2500* 2,300H 630, 1250, 2000
* 1,000D 800, 1250 800, 1250
PC Metering
Management PC Function I, V, W, +Wh, -Wh, Impedance (Monochrome) (Color)

CB state condition Line test Function


Controll Function
RGB Matrix Switch Interbreaking Function**
Trip circuit supervision
Trip counter monitoring Controlling Function(SWGR, CB)
Monitoring Function Other Video Sources
CB operate time Metering Function I, V, +Wh, -Wh, Impedance
System LAN-A(HUB) I alarm CB state condition
Self supervision Trip circuit supervision
System LAN-B(HUB)
Event records Visual Signal
Trip counter monitoring
Monitoring Function
Record Function Fault records Total Monitoring PCs Operator Console 1 Operator Console 2
CB operate time
Operator Console 3
Base Clock Main Server A Main Server B Main Server C I alarm
Disturbance records
Self supervision

5-3 DC Switchgear * Communication lines between the substations are required.

Record Function
Event records
Fault records 5-4 Protection Relay (GRX-200 Series)
Disturbancevent records
PS LAN-A(HUB)
Based on a strong experience and know-how on the supply of highly quality DC High Speed Circuit Breakers and
*Communication lineDC Switchgears
between the substation is requiered
PS LAN-B(HUB)
since theDS1970s, Toshiba
Negative Incoming developed
Feeder the HS5 DC
with
Feeder Panel Variations
DS Switchgear
with bypasswith
DS our own
with DS DC Protection
and bypass Bypass HSCB Relay which satisfies current global
Ratings
P18

market requirements. This highly reliable MTUDC Switchgear


MTU can efficiently undertake its critical roleBack
Main Bus
in railway power supply systems
Main Bus Main Bus Main Bus Main Bus

Up Console Power Supply Ranges 100 ~ 250 Vdc


such as detection and breaking of fault currents at a very high speed.
DS DS Line
test
HSCB Line
test
HSCB Line
test
HSCB Line
test
HSCB Line
test
HSCB

Device Device Device Device Device Communication Modbus / IEC61850 / IEC60870-5-103 /


HSCB
R Power Supply
R System LAN R R
RTU
R Protocol & Interface Web browser / DNP3.0 etc
LCD Language English / Chinese / Japanese
Ratings
P16 GRX200
RTU
GRX200
RTU
GRX200 GRX200

Bypass Bus
GRX200 GRX200
RTUP13
Bypass Bus
GRX200

Features Compact Design


DS GRX200

Rated Voltage [V] Substations


GRX200 DS DS DS
M
DC900 / 1800M M M
21F Distance Protection
Overcurrent Protection
Bypass Bus
Rated Bus Current [A] 4000 ~ 12000 51F
U> 64 DS DS DS DS Combined with I Delta I protection
Rated Short-circuit Making
Main Bus
and Breaking Current DC
[kA] 80 Protection Function 27F Voltage Protection
N
DC
SAR

Lightning Impulse [kV]


GRX200 SAR GRX200

20
DC
SAR GRX200
DC
SAR GRX200
DC Protection
79
Relay
Automatic Reclose
di / dt Current rate of rise protection
Rated Withstand Voltage 50 Over current protection (4 stages)
Power Frequency [kV] 9.2 User-friendly
50F Instantaneous Overcurrent Protection 49 Thermal overload protection (3 stages)
Applicable Standard JIS / IEC Protection
Human Interface
Multi-shots auto-reclosing function 32 Reverse Overcurrent protection (4 stages)
P16 Control Function Inter breaking function * 64 Grounding overvoltage protection (2 stages) GRX-200 Relay
Controlling function (SWGR, CB) 59 Over voltage protection (2 stages)
Typical Configuration Metering Function I, V, W, +Wh, Impedance 27 Under voltage protection (2 stages)
Event records Multi-shots auto-reclosing function
Feeder Panel Variations Monitoring Function FaultToshibas
records DC Switchgear Line test function
Negative DS Incoming Feeder with DS with bypass DS with DS and bypass Bypass HSCB
Main Bus Main Bus Main Bus Main Bus Main Bus
can berecords
Disturbance configured into Control Inter breaking function *
various
CB and common panel
DS status
DS DS Line
test
HSCB Line
test
HSCB Line
test
HSCB Line
test
HSCB Line
test
HSCB

configurations such as
Controlling function (SWGR, CB) Features Compact Design
Device Device Device Device Device CB and DS response monitoring Section compensation function
HSCB
R R R R
Record Function R
Trip feeder panels with DS,
circuit supervision Colored LCD Touch Screen for
Metering I, V, W, +Wh, -Wh, Impedance
Trip bypass DS, DS and
counter monitoring bypassby breaking level
categorized Human Interface
GRX200
GRX200
GRX200 GRX200 GRX200 GRX200 GRX200 Event records
Bypass Bus Bypass Bus
GRX200
and bypass HSCB.
Self-supervision Record Fault records Flexible Installation (The touch panel
GRX200 DS
DS DS DS
M M M M
Disturbance records and the main unit are separate.)
Bypass Bus
CB and DS status
U> 64
Main Bus
DS DS DS DS
Wide Range of Communication
CB and DS response monitoring
Protocol Supported
DC DC DC DC
N
SAR GRX200 SAR GRX200 SAR GRX200 SAR GRX200
Monitoring Trip circuit supervision
Trip counter monitoring categorized by breaking level Various Protection Elements
Self-supervision
Front View Side View of Feeder Panel
* Communication lines between the substations are required.
Negative Incoming Feeder1 Feeder2 Feeder3 Feeder4 Standby

Section Compensation Function


RELAY RELAY RELAY RELAY RELAY RELAY RELAY
When the train passes the section, sudden
PANEL PANEL PANEL PANEL PANEL PANEL PANEL
change of current might cause unnecessary trip.
I n order to avoid this situation, sec tion
compensation function is provided.
2300

Through the relay s user-


friendly HMI screen the circuit
breaker can be operated and
switchgear conditions can be
checked.

800 600 600 600 600 600 600

4400
Feeder Relay Mimic

Back View
This protection relay can generate, monitor and record wave forms during
failure occurences. Through this, detailed fault analysis can be performed.

LINE TEST DEVICE LINE TEST DEVICE LINE TEST DEVICE LINE TEST DEVICE LINE TEST DEVICE
*1 *2 *1 *2 *1 *2 *1 *2 *1 *2

89FZ1
DS M
89FZ1 89FZ2 89FZ3 89FZ4 HCT
4000A DS DS DS DS
M M M M
4000A 4000A 4000A 4000A HCT

SR(N) DCVT
*1 *1 *1 *1 *1
DS-1 DS-1 DS-1 DS-1

54F1 54F2 54F3 54F4 54FZ


HSCB HSCB HSCB HSCB HSCB
1500V DC Switchgear
54P
HCT 4000A DCVT 4000A DCVT 4000A DCVT 4000A DCVT 4000A
64P HCT HCT HCT HCT
HSCB
4000A *2 *2 *2 *2 *2

DCSAR DCSAR DCSAR DCSAR


RAIL
Section Compensation Principle PC Tool for Fault Waveform Function
17 18
800 600 600 600 600 600 600
Total Monitoring Display
Theory of Heat Pipe Cooling Radiation

Condensation
Fin

Heat radiation
=> condensation
Liquid Crystal Displays

Condensation
Maintenance Energy Printer Printer
Heat convection by PC Management PC (Monochrome) (Color)

Vapor Flow
pressure difference

Liquid Flow

Liquid Flow
RGB Matrix Switch
Pressure rise by
evaporation Other Video Sources
Evaporate
P6 P11
System LAN-A(HUB)
P14

High Speed Vacuum Circuit Breaker (HSVCB) Traction Energy Storage System with SCiB
Coolant evaporation by
Rated Voltage [kV] heat 72.5 ~ 252 Rated Voltage [kV] 36 / 72

5-5 5-7
System LAN-B(HUB)

Evaporation
Rated Interrupting Current [kA] 25 ~High
63 Purity Rated Bus Current [A] 1200 Cooling and Insulating Method Gas
Visual Signal
Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
Coolant and element

Heat
Rated Lightning Impulse Withstand Voltage [kV] 325 ~Water
1050 Rated Breaking Current [kA] 16 / 25 Rated
Total Monitoring PCs Operator Console 1 Operator Console 2
Applicable for up to 6MW Rectier
Operator Console 3
heat exchange Base Clock Main Server A Power
Main Server B Main Server C
Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Lightning Impulse [kV] 200 / 350
Toshiba has developed the innovative HSVCB. The HSVCB consists of theWithstand
Rated VCB, Capacitor,
Voltage Control and Protection units. The aerial arc Primary 77kV 35kV
Rated Gas Pressure 0.7(GCB) / 0.7(GIS) Power Frequency [kV] 70 / 140
chute and the contactor for the conventional HSCB are not used for the HSVCB. It contributes to safe operation and easy maintenance.
Rated Voltage System
Secondary Overview Applicable for DC600V / 750V / 1500V / 3000V
Applicable Standards JEC / IEC Rated Gas Pressure [MPaG] 0.05 (at 20C) Battery(SCiB)
Applicable Standard JEC / IEC
Toshiba developed Traction Energy Storage System (TESS)
Capacitor Unit
PS LAN-A(HUB)
with SCiB, an energy saving solution with Toshibas own
P11 Features P14 battery technology of high quality. TESS efficiently charges
P7 PS LAN-B(HUB) Converter
Control and Protection Unit Rated Voltage [kV] 36
and discharges surplus regenerative energy to/from
Cooling Method Vertical heat-pipe self cooling
GSR GSM / GSP GSPF Rated Current [A] 1200
SCiB. TESS is installedMTU with Toshibas
MTU patented advance Back Up Console
Rated Power
Rated Voltage [kV] 240 / 300 72 / 84 / 168 145 Safe OperationBetween Main Circuit and Earth 200 ~ 6 MW
V-SOC (Voltage-State-of-Charge) control system which
Lightning Rated Voltage DC 600V / 750V / 1500V / 3000V
Method of Operation Hydraulic Motor Spring Motor Spring Rated No Impulse
arc occurs during current breaking due to VCB application.
[kV] Between Main Circuit Terminals 250 allows flexible control of charge-discharge
Power Supply System LAN characteristics RTU
Withstand Applicable Standard JEC / IEC
Tank Dead Tank Live Tank in accordance to the batterys State-of-Charge (SOC). This
Voltage Low Noise Between Main Circuit and Earth 70 1min.
Power
Lighting RTU allows
RTU significant increase in battery lifetime. This system
RTU is
Frequency [kV] Between Main Circuit Terminals 100 10min.
Rated 900 / 1050 350 / 400 / 750 650 VCB application allows low noise.
Impulse [kV] useful not only for energy saving, but for various purposes
Substations
Withstand
Voltage Power 200-265-200(1min)/
P17
VCB Unit Rated Short Time Withstand 12.5 2sec. such as regenerated energy absorption, peak cut, feeder
DC Breaker TESS
Frequency [kV] 250-330-250(1min)
140 / 160 / 325 275 Low Maintenance
Current [kA]
Mechanical voltage compensation and emergency power supply.
Applicable Standards JEC / IEC Maintenance is free from
Switching Lifetime aerial arc200,000 times
chute and the contactor.
Outline of HSVCB Electrical 100,000 times
External Interface
DC-BUS
Converter Battery Panel
Receiving
1800W2380D2300H 600W650D2100H8 panels
P16
Open Command
Detecting
P8 Overcurrent
Control and Ratings
P17 P15
HCT Protection Unit
P6Rated Voltage [kV] 24 36 40.5 (HSTC)
72 84 P11
Rated Voltage [V] DC 750 , 1500 P14
Rated Lightning Impulse [kV]
Sub 125 170 185 350 400 1,000kWcontinuous rating
Feeder Panel Variations
Rated Voltage [kV] 72.5 ~ 252 Turn on the Rated Voltage
Rated Current [kV]
[A] 3000 , 4000 36 / 72
Withstand Valve Negative DS Incoming Regenerating
Feeder Inverter
with DSmode with bypass DS with DS and bypass Bypass HSCB
PowerCurrent
Frequency Open
70 Both25 Thyristor Switch Capacity 3,000kW1minute or 4,500kW-30seconds
Voltage
Rated Interrupting [kA] [kV]
close 50 95~ 63 140 160 Rated Bus
Rated Breaking Capacity
Current [A] [kA] 50 (at 3106A / sec), 100 (at 1010
1200 6A / sec)
Ratings
Main Bus Main Bus Main Bus Main Bus Main Bus
Valves Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
Rated Lightning Impulse Withstand Rated Breaking
Rated Short Time Current
Current [kA] 50-1sec , 100-1sec
[kA] 16 / 25 Powering Converter mode 1,000kWcontinuous rating only
Rated Current [A] openVoltage
630 [kV]
/ 1250 / 1250 325 ~ / 1050
800 / 1250 Rated Power
DS DS
test
Line HSCB Line
test
HSCB Line
test
HSCB
Applicable
Line
test for up to
HSCB
test 6MW Rectier
Line HSCB

2000 2000
Capacitor Charger

Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Applicable Standard JIS (To Impulse
Lightning be developed
[kV] for IEC)
200 / 350 Device Device Device Device Device
500kW~2000kW
Rated Withstand Voltage Primary 1,500VDC 77kV R Rated Power 35kV
/ 31.5 - / 0.7(GIS)
HSCB
R R R R
Rated Gas
Rated Short Time Withstand
Pressure Main 70 / 140 Rated Voltage Output control mode (Make a selection for your operation )
250.7(GCB) Power Frequency [kV] Rated Input Voltage Secondary Applicable for DC600V / 750VBattery / 1500VCapacity/ 3000V 200kWh~800kWh
Current [kA]
Applicable Standards
Valve
close JEC / IEC+ Rated Gas Pressure [MPaG] 0.05 (at 20C)
DC-1)Breaker
Load control: To 6 or 8 output Control regulation Panel 1500V(950V~2000V)
JEC / IEC Rated Voltage for Feeder side
GRX200

Applicable Standard JECoff/ IECon/ GB ApplicableGRX200


Standard -2) ConstantGRX200
voltage control GRX200 GRX200 GRX200 GRX200

When control and protection unit detects the over current or receives open command 600W1700D2100H2 panels 500W600D2100H2 Bypass Bus panels Bypass Bus
open Rated Voltage for Battery side
GRX200 600V(500V~713V)
from external devices, the both valves trip and the thyristor switch of capacitor unit is GRX200
Rated Output Voltage 1,200VAC
DS
M M
DS
M
DS
M
DS

VCB Unit P17the current of capacitor unit is in the opposite direction of the load/fault
turned on. Since Load 1p.u.(1min.) 0.5p.u.(4min.) or 0.5p.u.
BypassPattern
Thyristor Capacitor P11 P14 1Series * 2Parallel * 6Arm * 2Bridge Bus
continuous
current, the zero-cross point of DC current can be achieved. Therefore, the DC load/fault Main
U> Circuit64 Configuration
P7 Switch Unit Specifications Applicable equipments Double bridge parallel
DS DS
configuration DS
by Transformer DS

current can be broken with high reliability and safety. Main Bus
Rated Voltage [kV] 36 Cooling
DC DC DC DC

Device Method Vertical heat-pipe selfSARcooling


SAR SAR SAR
IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
GRX200 GRX200 GRX200 GRX200
Air Insulated type or
N

GSR Load /GSM


Fault/ GSP
Current GSPF MV Switchgear Unit 7.2 / 241200
/ 36kV
Rated Current [A] Solid Insulated type Rated Power ~ 6 MW
Device Cooling System Heat-pipe in pure water (natural cooling type)
Rated Voltage [kV] 240 / 300 of Cutting
Principle 72 / 84
off/DC
168Current 145
by HSVCB Between Main Circuit and Earth 200
Lightning Rated Voltage DC 600V / 750V / 1500V
Inverter-2,700W / 3000V
* 2,200D * 2,900H
Method of Operation Hydraulic Motor Spring Motor Spring Rated Impulse [kV] TR : Epoxy Resin Molded Dry
Between Main Circuit Terminals 250 Applicable
12-Pulse Rectifier Unit Up to 2,000kW
Withstand / Liquid Silicone Dimension Standard JEC / IEC
Control Panel of Inverter-800W * 1,000D * 2,300H
Tank Dead Tank Live Tank Power Between Main Circuit and EarthSelf-cooling
SR : Heat-pipe 70 1min.
Voltage DC Reacrtor-2,800W * 2,000D * 2,500H
Lighting Frequency [kV] Between Main Circuit Terminals 100 10min. Structure at Rated Power 500kW (mm)

Package-Type DC Substation
P10
Rated 900 / 1050 350 / 400 / 750 650 DC Switchgear Unit DC 600V, DC1500V HSCB or HSVCB
Impulse [kV]

5-6
Withstand Rated Short Time Withstand
Voltage
ApplicationPower 200-265-200(1min)/
Feeding System140 for/High Auxiliary[kA]
Power 12.5 2sec.
DC 110V,
160 /Speed
325 Railway275 Current Lead Storage Battery
Frequency [kV] 250-330-250(1min) Supply Unit AC 105V / 210V
Rated Voltage [kV] 220 / 25x 2 ; 161 / 60x 2 ; 132 / 27.5x 2 Mechanical 200,000 times
Applicable Standards JEC / IEC P7
Cooling Type ONAN / ONAF / OFAF Switching Lifetime
Toshiba has developed the compact Package-Type DC Electrical 100,000
Substation. It is suitable for small-capacity times and temporary
substations
Rated Power [MVA] 84 / 60
substations during rehabilitation work, and it reduces substation space.
Rated Voltage [kV] SCiB 36 40.5 72 84
Overload 200% 5mins Lightning Impulse [kV] 170 185 350 400
P13 Rated Withstand Voltage
Connection Scott SCiB Power
is a rechargeable
Frequency [kV]battery which
70uses Lithium Titanate
95 140 Attractive features 160
are realized
P8
Applicable Standard JECVIEW
FRONT / IEC 21F Distance Protection Rated Current [A] Oxide (LTO). Its features include
P15
safety,
630, 1250, 2500long life, rapid
630, 1250, 2000 800, 1250 by using Lithium
800,Titanate
1250
P17
51F Overcurrent Protection charging,
Rated Short Time Withstand high
Current [kA] power output performance,
25, 31.5 and good 25, 31.5 20, 25, 31.5 Oxide (LTO) 20,
in its
25,anode
31.5
Rated Voltage [kV] 24 36 40.5 72 84 Protection Function
Rated
Features
Rated Voltage [V] Compactness Voltage Protection
27FDC 750 , 1500 Applicable Standardscryogenic operation. JEC / IEC
Lightning Impulse [kV] 125 170 185 350 400 79 3000 , 4000
Automatic Reclose 1,000kWcontinuous rating
Rated Current [A]
Withstand Regenerating Inverter mode
P10
Voltage Power Frequency [kV] 50 70 95 140 160 Flexible
Rated Breaking Capacity [kA]
Layout
50 (at 310 A / sec), 100 (at 1010 A / sec)
6 6 Capacity 3,000kW1minute or 4,500kW-30seconds
Powering Converter mode 1,000kWcontinuous rating only * Results of cell level tests under certain conditions.
Example of Roof-delta 630 / 1250 / 1250 /
Connection Transformer Rated Short Time Current[kA]
Short Construction
50-1sec , 100-1sec Period Not a guaranteed performance.
Rated Current [A] 800 / 1250
2000 2000
Utility Feeding System for High Speed Railway
Applicable Standard JIS (To be developed for IEC)
System 1,500VDC
Design
Rated Short Time Withstand DC Output control mode (Make a selection for your operation )
Rated Voltage 25 / 31.5 Rated Input Voltage
Current [kA] [kV] 220kV / 60kV2 switchgear -1) Load control: To 6 or 8 output regulation
DC auxiliary In the introduction of TESS in a railway system,
-2) Constant voltage control P7
Cooling Type
Applicable Standard ONAN JEC / IEC / GB (Negative P12
Power it is important to do an accurate and reliable
Rated Power [MVA] 60 panel) P10
Overload 300% 2min
Ratings
P17
Rated
Rated Output [kV] simulation1,200VAC
VoltageVoltage of the traction power27.5 system during Rated Voltage [kV] 36 40.5 72 84
Rated Lightning Impulse [kV]
Rated Voltage [kV] 27.5 Rated Current [A] the design1Series
Main Circuit Configuration stage.* 2Parallel * 6Arm *1250
2Bridge 170 185 350 400
Connection Roof-delta Specifications Applicable equipments Double bridge parallel configuration by Transformer Withstand
Rated Lightning 200 (to earth and across open contacts) Lightning Impulse [kV] 250 Voltage Power Frequency [kV] 70 95 140 160
Applicable Standard JEC / IEC Withstand Impulse [kV] 220 (across isolating distance)type or Rated Withstand Voltage
Device IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
MV Switchgear Unit 7.2 / 24 / 36kV Air Insulated ToshibaPower
has many experience
Frequency [kV] and
95 consultation
Voltage 630 / 630 / 800 / 800 /
Solid Insulated type Device Cooling System Heat-pipe in pure water (natural cooling type) Rated Current [A]
(Line to Power 95 (to earth and across open contacts) know-how
Rated Short Time Withstand Currentfor[kA]
such energy simulation
25 required 1250 / 1250 / 1250 1250
Earth) Frequency [kV] 110 (across isolating distance)
TR : Epoxy Resin Molded Dry Inverter-2,700W * 2,200D * 2,900H 2500 2000
in designing a highly efficient total energy
/ Liquid Silicone Dimension Rated Short Time Withstand 25 / 25 / 20 / 25 / 20 / 25 /
P10 12-Pulse
Rated Current [A] Unit Up to 2,000kW
Rectifier 1250 Control Panel of Inverter-800W * 1,000D * 2,300H
saving solution for the customer.
SR : Heat-pipe Self-cooling Current [kA] 31.5 31.5 31.5 31.5
DC Reacrtor-2,800W * 2,000D * 2,500H
Rated Voltage [kV]Auxiliary
P10 AC
55 /switchgear
27.5
Rectifier DC switchgear
Rated Short Time Withstand 31.5 This simulation leads to a more suitable design of Applicable Standards JEC / IEC
(Power DC Switchgear
Current [kA] Unit DC 600V, DC1500V HSCB or HSVCB
Type Power Supply ONANReceiving equipment (Feeder panel) the TESS in terms of efficiency and cost as well.
panel panel) Auxiliary
ApplicablePower
Standard DC 110V,
Application
Self Capacity [MVA] Feeding System
4 / 5 / 7.5 / 10 for High Speed Railway IEC Lead Storage Battery
Rated Supply Unit AC 105V / 210V
Rated
PowerVoltage
Line [kV]
Capacity [MVA] 220 / 152 Outline
/ 25x
8 / 10 /; 161 of Package-Type
20 / 60x 2 ; 132 / 27.5x DC
2 Substation
P7
1
19 Cooling Type
Overload ONAN
300% /2min
ONAF / OFAF 20
Rated Power [MVA] 84 / 60
Can withstand thermally and mechanically Rated Voltage [kV] 36 40.5 72 84
Short Circuit Intensity
Overload for 255mins
200% or 35 times of the rated current Lightning Impulse [kV] 170 185 350 400
P13 Rated Withstand Voltage
Applicable Standard
Connection JEC / IEC
Scott Power Frequency [kV] 70 95 140 160
Applicable Standard JEC / IEC 21F Distance Protection Rated Current [A] 630, 1250, 2500 630, 1250, 2000 800, 1250 800, 1250
51F Overcurrent Protection Rated Short Time Withstand Current [kA] 25, 31.5 25, 31.5 20, 25, 31.5 20, 25, 31.5
Protection Function
6 Power SCADA
5-8 Regenerative Inverter
The regenerative inverter is P15
an ideal solution for regenerative braking power from rolling stocks. It converts the DC regenerative
power back to AC power and supplies it to the auxiliary system for passenger stations. Toshiba supplies the IGBT inverters with Overview Features
heat pipe cooling systems.

Toshiba produces Supervisory Control And Data Acquisition (SCADA)


systems for railway power supply systems with ICT which enables
1. High Reliability by Triple Servers
Power Source
The triple-server system enables highly reliable operation. It can allow
stable and highly-reliable train operations. Toshibas abundant duplex servers operation even while maintenance and training. Of
expertise allows for production of user-friendly systems. For instance, course, each of the three servers can be changed automatically or
Features when a fault occurs on the distribution network, many fault signals manually to service, standby or simulation mode.
will be sent simultaneously from some substations to the SCADA
Transformer
2. Server-less Manual Control on Console
server in the Control Center. The operator would subsequently
The performance of the IGBT inverters has been The substation monitoring and the individual manual control functions are
become confused by the many faults and alarms. Our system installed in the Console PC. These functions are therefore available even if
upgraded in comparison with conventional
IGBT therefore collects related information and displays what originally the connection between the servers and Remote Terminal Unit (RTU) fails.
Regenerative Escalator Lighting thyristor inverters.
Inverter happened, and then activates recovery control or shows the recovery
procedure to the operator. In addition, the simulation function 3. Remote Back-up Console for Emergencies
Traction Substation Passenger Station Facility
Reduces Harmonics provides training for immediate and exact recovery. Installing the Console PC in the substation makes remote back up
control possible from the substations.
Harmonics distortion can be reduced due to the advanced Toshiba takes customers requirements into account in its flexible
gate control. approach to producing SCADA systems. 4. Registered Sequential Control
High Power Factor This function controls multiple local equipment sequentially with one
action. The operator can define and register the condition, equipment
The power factor is close to 1.0. to be controlled, and sequence depending on their usability.
Decelerating / Regeneration by Brake Accelerating / Powering

Low Loss 5. Fault Recovery Control


In case of a fault in some substations or the distribution network, the
Easy Operation and Maintenance fault recovery control (consisting of reclosing tripped circuit breakers,
P14
A touch screen on the panel for operation and maintenance. fault location control, etc.) will be done automatically or manually while
36 / 72 displaying recovery procedure to facilitate immediate and exact recovery.
1200 Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
16 / 25 Rated Power Applicable for up to 6MW Rectier
6. Simulation (Training)
200 / 350 This function provides training for operators and conducts test for
Primary 77kV 35kV
70 / 140 Rated Voltage maintenance with a pair of servers and with the operator console in off-
Secondary P13 Applicable for DC600V / 750V / 1500V / 3000V line status with all substations. Playing the Simulation Scenario which
0.05 (at 20C) Applicable Standard JEC / IEC can be made from actual event logs simulates faults and circuit breakers
P14 P18 tripped as if actual accidents had happened. This allows the operator to
experience training that is effective for immediate and exact recovery.
TO POWER COMPANY 3 phase NETWORK
P14

Cooling Method Vertical heat-pipe self cooling


Rated Power ~ 6 MW
Heat
and Earth 200 Rated Voltage DC 600V /Theory
750V / 1500V / 3000V Total Monitoring Display
of Heat Pipe Cooling Radiation
Condensation

Terminals 250 Fin


Applicable Standard JEC / IEC
and Earth 70 1min. Heat radiation
Terminals 100 10min. => condensation
Liquid Crystal Displays
Condensation

Maintenance Energy Printer Printer


Heat convection by PC Management PC (Monochrome) (Color)
Vapor Flow

pressure difference
imes
Liquid Flow

Liquid Flow

Regenerative Inverter RGB Matrix Switch


es Pressure rise by
evaporation Other Video Sources
Evaporate
System LAN-A(HUB)
Coolant evaporation by
heat System LAN-B(HUB)
P15
Evaporation

Ratings Coolant and element


High Purity Visual Signal
Heat

Water Total Monitoring PCs Operator Console 1 Operator Console 2 Operator Console 3
heat exchange Base Clock Main Server A Main Server B Main Server C
1,000kWcontinuous rating
Regenerating Inverter mode
00 (at 1010 6A / sec) Capacity 3,000kW1minute or 4,500kW-30seconds
Powering Converter mode 1,000kWcontinuous rating only
for IEC) 1,500VDC
Rated Input Voltage Output control mode (Make a selection for your operation ) PS LAN-A(HUB)
-1) Load control: To 6 or 8 output regulation
-2) Constant voltage control PS LAN-B(HUB)

Rated Output Voltage 1,200VAC MTU MTU Back Up Console


1Series * 2Parallel * 6Arm * 2Bridge
Main Circuit Configuration
plicable equipments Double bridge parallel configuration by Transformer Power Supply System LAN RTU
sulated type or Device IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
Insulated type Device Cooling System Heat-pipe in pure water (natural cooling type) RTU RTU RTU

poxy Resin Molded Dry Inverter-2,700W * 2,200D * 2,900H Substations


Liquid Silicone
eat-pipe Self-cooling
Dimension
P17
Control Panel of Inverter-800W * 1,000D * 2,300H
DC Reacrtor-2,800W * 2,000D * 2,500H Typical System Configuration
or HSVCB
21 22
Storage Battery External Interface
DC-BUS Receiving
P7
P16
Open Command
Detecting
Overcurrent
Rated Voltage [kV] 36 Control and40.5 72 84
Lightning Impulse [kV] HCT 170 Protection Unit
185 350 400
Toshibas Station Energy Solution Photovoltaic Systems
Toshiba is capable of devising photovoltaic power and energy solutions that fit specific projects.
Toshiba proposes the new idea of Station Energy Solution. It will realize the effective utilization of energy and Engineering know-how, expertise in system development and construction, and a seamless
contribute to environment friendly society. This solution consists of photovoltaic system, regenerative inverter service network that spans the globe are crucial requisites. Toshiba has the experience and
system, battery system and total energy management system. technology to make solar a successful strategy.

500kW Power Conditioning System (PCS)


High efficiency, compact design, and low cost due to
Photovoltaic Panel
recently developed converter circuit.
Standardization by configuration into separate DC
input/Converter/AC output cabinets to enable easy
application as the core of the power plant and to
provide various options for localization.
Less depth for easy container installation.

OIT

52m
OIT

Safe
Using safe material
(LTO)
Regenerative Inverter System Traction Energy Storage System with SCiB Low Temperature High Effective
Operation Capacity
Regenerative DC power from an electronic train converted to AC Regenerative DC power AIS
can now be stored in Toshibas Traction Energy Storage Super Charge Ion Battery (SCiB) Usable in extremely Attractive features are realized by High amount of actual
power via a Regenerative Power Inverter. The AC power is then System which utilizes high performance SCiB batteries. It is controlled cold enviroments usable energy over
using Lithium Titanate Oxide
supplied to nearby passenger stations for auxiliary power (e.g. using a special control system with Toshibas own propriety technology that SCiB is a rechargeable battery. (-30C)
(LTO) in its anode
wide range of SOC
Lighting, Escalators, etc.) promotes batteries longer lifetime. With the use of this equipment, each By using unique oxide materials, SCiB holds high resistance toward
substation can not only thermal runaway resulting from short circuiting caused by physical
save regenerative power stress. SCiB also has good characteristics such as, long life with small
but it can also help promote capacity loss even after 6,000 full charge-discharge cycles, rapid
power peak cut, compensate charging capability with ability to charge 80% of the capacity in as fast Rapid High
voltage unbalance and be 16m as approx. 6 minutes. High power output with performance equivalent Recharging Input & Output
used as emergency power to that of an EDLC (Electric Double-Layer Capacitors), and good Recharges Usable with
in approx. 6 minutes high current
system.43m cryogenic performance with ability to function even at -30C.
Long Life
GIT Over 6,000 charge-
Regenerative discharge cycles
GIS * Results of cell level tests under certain
Inverter SCiB Battery Panel conditions. Not a guaranteed

23 24
11m
GIT
Global Network
Global operations; Japan Global operations; Asia

X Sales / Engineering / Rep Office 1 Head Office (Tokyo, Japan) X Sales / Engineering / Rep Office 32 (TIPL) Toshiba India Private Ltd.
7
Y Production Factory Corporate Staff Y Production Factory
Sales 33 (TAPL) Toshiba Asia Pacific Pte., Ltd. (Singapore)
Engineering
8 34 (TAPL) Toshiba Asia Pacific Pte., Ltd. (Bangkok)
Japan 2 Smart Community Center [Kawasaki, Japan]
Corporate Staff 35 (TAPL) Toshiba Asia Pacific Pte., Ltd. (Kuala Lumpur)
Sales 32 40 38
9 6 Engineering 37 36 (TAPL) Toshiba Asia Pacific Pte., Ltd. (Jakarta)
4 1 India, South East Asia
10 3 2 3 Hamakawasaki Operations 34 37 (TAPL) Toshiba Asia Pacific Pte., Ltd. (Manila)
13 12 11 5 Transformers
14 35 39
7 Hokkaido Branch Switchgears 38 (TTDV) Toshiba Transmission & Distribution Vietnam
Surge Arresters 33 Protection Relays
8 Tohoku Branch On Line Monitoring Systems Substation Automation Systems
36
9 Hokuriku Branch
4 Fuchu Complex 39 (TTDA) Toshiba Transmission
10 Chubu Branch Protection System & Distribution Systems Asia Sdn. Bhd.
11 Kansai Branch Substation Automation System Medium Voltage Switchgears
System Solution vacuum Circuit Breakers
12 Shikoku Branch Medium Voltage Switchgears Ring Main Units, Compact Substations,
EPC of T&D Systems
13 Chugoku Branch 5 Mie Operations
14 Kyushu Branch Distribution Transformers 40 (TTDI) Toshiba Transmission & Distribution Systems India
Power Transformers EHV, UV, Transformers
Protection Equipment Medium Voltage Switchgears
Power Distribution Equipment
6 Kitashiba Electric Co., Ltd.
Distribution Transformers
Power Transformers

Global operations; China Global operations; EMEA and Russia

X Sales / Engineering / Rep Office 15 (TBV) Toshiba Baiyun Vacuum Interrupters (Jinzhou) Co., Ltd. X Sales / Engineering / Rep Office 41 (TIL) Toshiba International (Europe) Ltd. (Durham)
16 23 15 Vacuum Circuit Breakers
Y Production Factory Y Production Factory
China 17 18
42 (TTDE) Toshiba Transmission & Distribution Europe
16 (ETA) EPRI Toshiba Arrester Co., Ltd. 46 EPC of substations
20 19 Surge Arresters (~1,100kV) EPC of PV plants
41
21 17 (PTC) Henan Pinggao Toshiba High-Voltage Switchgear Co., Ltd. 42 43 (JHB) Toshiba Johannesburg Rep. Office
22
High Voltage Switchgears (110~1,100kV)
44 EMEA and Russia 44 (TTDG) Toshiba T&D Systems Gulf SPC. (Abu Dhabi)
18 (CTC) Changzhou Toshiba Transformer Co., Ltd. 45
Large Capacity Transformers (~1,100kV) 45 (TTDG) Toshiba T&D Systems Gulf SPC. (Bahrain)

19 (CTS) Changzhou Toshiba Shuidian Transformer Co., Ltd. 46 (TCIS) Toshiba CIS LLC (Moscow)
Distribution Transformers

20 (THC) CET Toshiba (Henan) Switchgear Components


Manufacturing Co., Ltd.
High Voltage Switchgear Parts 43
21 (GTBS) Guangzhou Toshiba Baiyun Electrical Equipment Co., Ltd.
MV Switchgears

22 (JPC) Zhuhai Xujizhi Power System Automation Co., Ltd.


Distribution Automation System (DAS)

23 (TCH) Toshiba China Co., Ltd.


1 Headquarter in Beijing and 7 Branch Offices in Shanghai,
Guangzhou, Chengdu, Jinan, Xian, Wuhan and Hargzhou

Global operations; NA and SA Global operations; Oceania

X Sales / Engineering / Rep Office 24 (TIC-US) Toshiba International Corp. (Houston) X Sales / Engineering / Rep Office 47 (TIC AUS) Toshiba Intl Corp. (Sydney)
Y Production Factory Headquarters Y Production Factory
Power conditioner, Battery Energy Storage 48 (TIC AUS) Toshiba Intl Corp. (Brisbane)

25 (TIC-US) Toshiba Intl Corp. (Denver) 49 (TIC AUS) Toshiba Intl Corp. (Melbourne)

26 (TIC-US) Toshiba Intl Corp. (San Francisco) Oceania 48 50 (TIC AUS) Toshiba Intl Corp. (Perth)

26 25 27 (TDV) Toshiba de Venezuela C.A. 50


47
24
28 (TDV) Toshiba de Venezuela C.A. Columbia 49
American Continent
29 (TIC-SA) Toshiba Infrastructure Systems
27 South America Ltd. Headquarters (So Paulo)
28
30 (TIC-SA) Transformer Factory
Power Transformers
30 Distribution Transformers
31 29
31 (TIC-SA) Switchgear Factory
Air Insulated Switchgears
Surge Arresters
Protection Relay
Turn-Key Engineering

25 26

S-ar putea să vă placă și