Chiller selection software

DAIKIN CSS - Rev. 9.5


Printing date: 14/02/2017

SERIES: EWYQ-BAWP

SERIES: EWYQ-BAWP_MAX

GENERAL CHARACTERISTICS

-Inverter chiller
-High efficiency with leader-of-class ESEER (up to 4.33)
-Minimal starting currents and short payback times
-No buffertank required for standard applications
-Daikin scroll compressor
-Large operation range (ambient temperature up to 43C)
-Digital remote controller

Page 1 of 4
Chiller selection software
DAIKIN CSS - Rev. 9.5
Printing date: 14/02/2017

GENERAL CHARACTERISTICS

-Inverter chiller
-High efficiency with leader-of-class ESEER (up to 4.33)
-Minimal starting currents and short payback times
-No buffertank required for standard applications
-Daikin scroll compressor
-Large operation range (ambient temperature up to 43C)
-Digital remote controller

Page 2 of 4
Chiller selection software
DAIKIN CSS - Rev. 9.5
Printing date: 14/02/2017

TECHNICAL SPECIFICATIONS - COOLING MODE (data referred to EN14511)


MODEL EWYQ064BAWP EWYQ064BAWP_MAX

Capacity - Cooling kW 62,3 74,2


Capacity control - Type Inverter controlled Inverter controlled
Unit power input - Cooling kW 27,4 39,9
EER 2,28 1,86
ESEER 3,64 3,64

CASING
Colour * Daikin White Daikin White
Material * GPSS GPSS

DIMENSIONS
Height mm 1684 1684
Width mm 2980 2980
Length mm 780 780

WEIGHT
Unit Weight kg 730 730
Operating Weight kg 738 738

WATER HEAT EXCHANGER


Type * Brazed plate Brazed plate
Fluid Water Water
Fouling factor m C/W 0,0000176 0,0000176
Water Volume l 6 6
Water temperature (in/out) C 12,0/7,0 12,0/7,0
Nominal water flow rate - Cooling l/s 3,0 3,5
Nominal Water pressure drop - Cooling ** kPa 66 83
Insulation material * Nitrile rubber based Nitrile rubber based
elastomeric foam elastomeric foam

AIR HEAT EXCHANGER


Type * HI-XSS HI-XSS

FAN
Type * Direct drive Direct drive
On/Off fans On/Off fans
Drive *
Air temperature C 35,0 35,0

COMPRESSOR
Type Hermetically sealed scroll Hermetically sealed scroll
compressor compressor
Quantity No. 6 6

SOUND LEVEL
Sound Power - Cooling*** dB(A) 83 83

REFRIGERANT CIRCUIT
Refrigerant type R410A R410A
Refrigerant charge kg 19 19
N. of circuits No. 1 1

PIPING CONNECTIONS
Evaporator water inlet/outlet 2" (female) 2" (female)

* IW: Ivory White - GPSS: Galvanized and Painted Steel Sheet - PHE: Plate Heat Exchanger - S&T: Single Pass Shell & Tube.* CC:
Closed Cell - HFP: High efficiency fin and tube type - DPT: Direct Propeller Type - DOL: Direct On Line - VFD: Inverter - BRS:
Brushless.** If red contact factory.***sound power level (@STD conditions) are mesuared in accordance with ISO 9614 and
Eurovent 8/1 for Eurovent certified units

Page 3 of 4
Chiller selection software
DAIKIN CSS - Rev. 9.5
Printing date: 14/02/2017

TECHNICAL SPECIFICATIONS - HEATING MODE


MODEL EWYQ064BAWP EWYQ064BAWP_MAX

Capacity - Heating * kW 63,7 75,6


Unit power input - Heating * kW 21,8 26,8
COP * --- 2,92 2,82

HEAT EXCHANGER - EVAPORATOR


Nominal water flow rate l/s 3,0 3,6
Nominal Water pressure drop kPa 68 85

Fluid: Water
* Heating capacity, unit power input and COP are based on the following conditions: air exchanger 7,0 - 85%C; water exchanger
40,0/45,0, unit at full load operation;

ELECTRICAL SPECIFICATIONS
MODEL EWYQ064BAWP EWYQ064BAWP_MAX

POWER SUPPLY
Phases Nr 3 3
Frequency Hz 50 50
Voltage V 400 400
Voltage tolerance Minimum % -10 -10
Voltage tolerance Maximum % 10 10

COMPRESSORS
Phases Nr 3 3
Voltage V 400 400
Starting method ---

Allowed voltage tolerance 10%. Voltage unbalance between phases must be within 3%. Maximum starting current: starting
current of biggest compressor + current of the compressor at 75% maximum load + fans current for the circuit at 75%.Nominal
current in cooling mode is referred to the following conditions: evaporator 12/7C; ambient 35C; compressors + fans
current.Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed
current.Maximum unit current for wires sizing is based on minimum allowed voltage.Maximum current for wires sizing:
(compressors full load ampere + fans current) x 1,1.(1) Running current based on the following conditions: evaporator
12,0/7,0C; ambient 35,0C;Fluid: Water

For more information, please refer to following web address:


http://www.daikineurope.com/products/index.jsp?singleprv=EWYQ-BAWP

Page 4 of 4