American Journal of Analytical Chemistry, 2011, 2, 857-862

doi:10.4236/ajac.2011.28098 Published Online December 2011 (http://www.SciRP.org/journal/ajac)

Determination of Compositions in Cosmetics by


Multiple-Instrument
Changming Zhang1*, Shaoqing Guo2, Changgen Huang1
1
State Key Laboratory of Coal Conversion, Institute of Coal Chemistry, Chinese Academy of
Sciences, Taiyuan, China
2
Taiyuan University of Science and Technology, Taiyuan, China
E-mail: zhangcm@sxicc.ac.cn
Received January 21, 2011; revised April 12, 2011; accepted April 23, 2011

Abstract

An analysis method based on multi-instruments analysis technique coupled solvent extraction to determine
compositions of unknown cosmetic were established. The multi-instruments involve high-performance liquid
chromatography (HPLC), X-ray diffraction (XRD) and Fourier transform infrared (FTIR). The cosmetic
sample was separated and enriched into 4 fractions by the solvent extraction. The compounds were defined
as mercuric ammonium chloride, liquid paraffin, etc.

Keywords: Cosmetic, Analysis, Multi-Instruments, HPLC, FTIR

1. Introduction time, most of these methods were used to determine the


total amount of metal rather than the metal form. Majidi
In modern life, there is more and more emphasis on pro- [13] and Gudzenko [15] reported the determination of
tecting and beautifying facial skin, especially for young methyl mercury and ethyl mercury, and Evans reported
women, and more and more types of cosmetic products the determination of three forms of mercury including
could be found in cosmetics market. However, it is nec- CH3 , C2 H5 and C6 H13 [7]. In addition, there is no
essary to point out that some cosmetics used for a long report about determination of the heavy metal form and
-time may lead to damage of human health due to the simultaneous detection of multi-components in cosmet-
presence of certain harmful substances. For example, ics.
there are a lot of reports about harmful substances being In literature [7-14], there is no report about determina-
prohibited or restricted in cosmetics. They could be de- tion of the heavy metal form and this method established
tected through instruments analysis, including carcino- can analyze the form and content of heavy metal of cos-
gens-N-nitroso-diethanolamine [1], formaldehyde [2], metic.
preservatives [3] hormone [4], antibiotics [5], phenolies Many methods were only used to detect a single com-
[6] and so on. ponent of cosmetic [1-6], and was not useful to defect
Many methods to detect specific components [1, 2-6] many compounds. So the successful enrichment is to
and heavy metals of cosmetics were reported in lots of ensure instrument analysis. The enrichment principle of
literature. For example electrochemical detector detec- components is mainly based on the different solubility of
tion (EC) [8], cold vapor atomic absorption spectrometry components in solvents.
(CVAAS) [8,9], atomic emission spectroscopy (AES) If this component of sample has same group of solvent,
[10], and inductively coupled plasma mass spectrometry then it may be easier to be dissolve and concentrate than
(ICP-MS) [11,12], and so on. There are also some re- the components. For example, when water was used as
ports using capillary electrophoresis (CE) combining extraction reagent, the solubility alcohols were much
with inductively coupled plasma mass spectrometry (CE- higher than other no-coating OH- compounds, and then
ICPMS) [13,14] and capillary electrophoresis combining this fraction were mainly alcohol compounds.
with UV-Vis detection for heavy metals speciation The present analysis methods and the treatment of
[15,16]. These methods have high sensitivity and low samples have some characteristics; this has not been re-
selectivity for detection of heavy metals; at the same ported and will be a reference for related analysis.

Copyright 2011 SciRes. AJAC


858 C. M. ZHANG ET AL.

2. Experimental and denoted as fraction 2, which was analyzed by HPLC.


The dried fraction 2 was analyzed by FTIR.
2.1. Instruments, Reagents and Samples 3) Separation of fraction 3
The above hexane-insoluble substances were dissolved
HPLC analysis was performed on a Shimadzu LC-3A and extracted with 100 ml trichloromethane. The other
high performance liquid chromatograph (Shimadzu Co., extraction operations were similar to the above-men-
Japan), with a UVD ultraviolet detector, and a RID 3A tioned process. The chloroform-soluble substance was
differential refractometer. The chromatographic columns denoted as fraction 3 and analyzed by HPLC.
used were Zorbax-ODS, Zorbax-NH2 and. SHIMPACK 4) Preparations of fraction 4
GPC-801, the all of them provided by Shimadzu Com- The above chloroform -insoluble substances were ex-
pany. tracted with 50 ml THF, and then were filtrated. The
XRD analysis was performed on a Riguku D/Max insoluble residue with 50 ml THF was extracted again.
2500 system. The THF soluble substances were denoted as fraction 4
FTIR determination was performed on a Bio-Rad Ex- and analyzed by HPLC. The dried samples were ana-
calibur Series FTS 3000 spectrometer in the range of lyzed by XRD and FTIR.
4000 - 400 cm1 using KBr pellets.
Analytical-grade methanol, hexane, tetrahydrofuran, 2.2.2. The conditions of multi-instrument analyses
chloroform, benzene and ethylene glycol obtained from 1) HPLC analysis
Tianjin Chemical Reagent Factory (Tianjin, China). Pure For analysis of fraction 1, R.I.D-3A differential re-
mercuric ammonium chloride, stearic acid, linoleic acid , fractometer and a Zorbax-ODS column were used. Pure-
-linoleic acid ethyl ester, 1,2-propanediol, 1,3-pro- water was used as mobile phase, with a rate of 0.8
panediol, liquid paraffin, polyethylene glycol and glyc- ml/min and column temperature at 20C.
erol, etc were from Shanghai Chemical and Medical Re- For analysis of fraction 2, differential refractometer
agent Company (Shanghai, China). and a Zorbax-NH2 column were used hexane was used as
The cosmetic sample was unknown, which was pro- mobile phase, with a rate of 1.0 ml/min and column tem-
vided by the relating departments of Cosmetics Company perature at 20C.
of Taiyuan city in Shanxi Province (China). For analysis of fraction 3, UV detector at 254 nm and
a Zorbax-NH2 column were used. The heptanes/ chloro-
2.2. Experimental Methods form = 1/1 (V/V) was used as mobile phase, with a rate
of 0.9 ml/min and column temperature at 23C.
2.2.1. Preparations of Fractions by Extraction For analysis of fraction 4the flow rate of THF was
The first step is obtaining optimum conditions for en- 1.0ml/min and the temperature of the column was kept at
richment and separation of fractions. A series of experi- 25C. The wavelength () of UV detector was at 270 nm.
mental factors were investigated involving different re- 2) FTIR analysis
agents and extraction order. The most optimum condition For analysis of fraction 1, fraction 2 and fraction 4, FTIR
was defined, which were described as follows. was used. The spectra of Fourier transform infrared
1) Separation of fraction 1 (FTIR) were acquired in the transmission mode as 64
The operation procedure of extraction: 1.5 - 2 g of scan in the IR range from 4000 to 5000 cm1 at a resolu-
cosmetic sample was weighed with accurate of 0.00001 tion of 4 cm1. KBr standard pellets were used, and the
grams, and then placed into a 250 ml of Separatory Fun- samples were dried and then mixed with KBr, ground,
nels; 100 ml of distilled water was added into the funnels; and palletized.
they were mixed fully by shaking, and then centrifuged. 3) XRD analysis
Then they were rested until the both layers appeared. These For analysis of dried fraction 4 XRD was used. Dif-
water-soluble liquids were denoted as fraction 1, which fraction patterns were recorded with Cu K ( = 0.1542
was subjected to fixed volume and analyzed by HPLC. nm) radiation and the X-ray tube was operated at 40 KV
Preparation of sample for FTIR analysis was that 10 ml and 100 mA. Step scans were taken over the range of 2
of fraction 1 was placed into a Petri dish, under nitrogen from 10 to 70 at a speed of 2/min.
at 90C for remove water and the dried fraction 1 was got.
2) Separation of fraction 2 3. Results and Discussion
The above water-insoluble substances were placed
into a Separatory Funnel and mixed with 100 ml hexane. 3.1. Analysis Results of Fraction 1
The extraction operations were similar to the above-men-
tioned process. Then the hexane-soluble liquid was got The typical HPLC chromatograms of fraction 1 are shown

Copyright 2011 SciRes. AJAC


C. M. ZHANG ET AL. 859

in Figure 1. The identities of components were checked bility alcohols were much higher than other no-soluble
by retention time of pure reagents. The qualitative results compounds, and thus, fraction 1 were mainly substances
show that the main components of fraction 1 were poly- of alcohol.
ethylene glycol 200, ethylene glycol, 1,2-propanediol
and glycerin. 3.2. Analysis Results of Fraction 2
The IR spectra of fraction 1 and pure reagents includ-
ing ethanol, glycerol and 1,3-propanediol was shown in The fraction 2 was analyzed by FTIR. The IR spectra
Figure 2. It can be seen evidently, that IR characteristic were shown in Figure 3. It can be seen that the charac-
of fraction 1 is basically same as that of reagents. The teristics of fraction 2 and relational pure reagents were
characteristic peaks around 3316 cm1, 2920 cm1, 1400 basically same. The IR characteristics peaks of 719.45
cm1, and 1044 cm1 respectively are attributed to OH-, cm1, 1377.17 cm1, 2850.78 cm1, 2918.29 cm1 and
CH2, CH3 and C-O group, respectively. 2959.79 cm1 were attributed to peaks of alkanes.
When water was used as extraction reagent, the solu- In HPLC analysis (Figure 4), the liquid paraffin in
fraction 2 was eluted as one peak firstly and its retention
1.4 time was less than benzene (added in). While normal
1. Polyethylene glycol 200
phase chromatography systems (Zorbax-NH2-hexane
2. Glycerol
1.2
3. Ethyl alcohol
system) were used, the non-polar liquid paraffin must be
4. 1,2-Propanediol
4 eluted first [17].
1.0
Through analysis of FTIR and HPLC, finally, the main
composition of fraction 2 was defined as liquid paraf-
0.8
fin.These results imply that liquid paraffin has same CH2
mv

and CH3 groups of hexane, so it might exhibit better


0.6
solubility than other components.
2
1
0.4 3 5 3.3. Analysis Results of Fraction 3
0.2
0 2 4 6 8 10
The fraction 3 was analyzed by HPLC and chroma-
t/min togram was shown in Figure 5. Through retention times
comparisons of sample with pure reagents, finally, li-
Figure 1. The HPLC chromatogram of fraction 1; Chro- noleic acid, stearic acid, linoleic acid methyl ester and
matographic conditions: Shimadzu LC-3A HPLC chro-
matograph Detectors: R. I. D-3A differential refractome- -linoleic acid ethyl ester were defined as main compo-
ter detector a Column: 0.46 25 cm, packed with Zor- nents in fraction 3.
bax-ODS, 5 m; Column temperature: 20C. Mobile In order to further verify the qualitative analysis, the
phase: pure water; Flow rate: 0.8 ml/min. Peaks order: [1] blank experimental about solubility was conducted.
Polyethylene glycol 200 [2] Glycerol [3] Ethyl alcohol [4] The pure reagents which involved linoleic acid, stearic
1,2-propanediol. acid, linoleic acid methyl ester and -linoleic acid ethyl

1,3-Propanediel
C22H46

Glycerel C28H48

C36H74
Ethylalcohol

Fraction 2

Fraction 1

4000 3500 3000 2500 2000 1500 1000 500 4000 3500 3000 2500 2000 1500 1000 500
-1
Frequency CM Frequncy CM
-1

Figure 2. The IR spectra of fraction 1 and pure reagents. Figure 3. The IR spectra of fraction 2 and pure reagents.

Copyright 2011 SciRes. AJAC


860 C. M. ZHANG ET AL.

12 spectra were shown in Figure 6 and Figure 7, respec-


Benzene added
tively. It obviously can be seen that the XRD characteris-
10 tics of fraction 4 were same as that of corresponding pure
2 mercuric ammonium chloride (HgNH2Cl). In IR spec-
8
trums, the characteristics of fraction 4 were also basically
same as that of pure reagent HgNH2Cl. The fraction 4
6
was analyzed by HPLC and chromatogram was shown in
mv

4 Figure 8. The blank experimental was done and the


Liquid paraffin 1 results indicate the pure mercuric ammonium chloride
2 only can be dissolved in THF.
It is necessary to emphasize that the mercuric ammo-
0 nium chloride exhibits highly toxic even at much lower
0 1 2 3 4 5 6
concentrations. It can be easily deposited on skin surface
t/min and transmitted by mobile blood. If they were used for
Figure 4. The HPLC chromatogram of fraction 2. Chro- long-time, eventually, it will cause kidney failure and
matographic conditions: Shimadzu LC-3A HPLC chro- nervous system damage, including loss of motor skills
matograph; Detectors: R.I.D-3A differential refractometer and personality changes, etc. It is a serious problem, so
detector a Column: 0.46 25 cm, packed Zorbax-NH2, 5 consumers and managers of cosmetics must pay great
m Column temperature: 20C. Mobile phase: n-hexane; attention to it.
Flow rate: 1.0 ml/min. Peak: order [1] Liquid paraffin [2]
Benzene added.

HgNH2CL
1 Linoleic acid
2 Stearic acid
3 Linoleic acid methyl ester
4 a - Linoleic acid ethyl ester 4

Fraction 4

2
1 3

20 30 40 50 60 70
Theta
0 2 4 6 8 10
t/min Figure 6. The XRD spectra of fraction 4 and pure
HgNH2CL.

Figure 5. The HPLC chromatogram of fraction 3 Chroma-


tographic conditions: Shimadzu LC-3A HPLC chromato- HgNH2CL
graph; Detectors: UV detector, 254 nm; Column: 0.46 25
cm, packed with Zorbax-NH2, 5 m; Column temperature:
20C. Mobile phase: heptanes/trichloromethane = 1/1 (V/V);
Flow rate: 0.9 ml/min. Column temperature: 23C; Peak
order: [1] linoleic acid [2] stearic acid [3] linoleic acid
methyl ester [4] -linoleic acid ethyl ester. Fraction 4

ester were selected, and then they were dissolved by wa-


ter, hexane, and trichloromethane, respectively, to see
their dissolution natures. The results indicated they are
better soluble in chloroform.
3500 3000 2500 2000 1500 1000 500
3.4. Analysis Results of Fraction 4 -1
Frequency CM

The fraction 4 was analyzed by XRD and FTIR. Their Figure 7. The IR spectra of fraction 4 and pure HgNH2CL.

Copyright 2011 SciRes. AJAC


C. M. ZHANG ET AL. 861

1.8 Table 1. Quantitative result of components.


1.6
Components (1) (W%) (2) (W%) Average (W%)
1.4
Mercuric
HgNH2CL 0.26 101 0.24 101 0.25 101
1.2 ammonium chloride
Polyethylene
1.0 1.52 1.22 1.27
glycol 200
MV

0.8
Glycerin 6.95 7.01 6.98
0.6
Ethylene glycol 0.83 0.97 0.90
0.4

Fraction 4 1,2-Propanediol 13.57 13.62 13.59


0.2
Linoleic acid 10.12 10.03 10.07
0.0

0 2 4 6 8 10 12 Stearic acid 11.41 11.63 11.52


Min. linoleic acid methyl ester 0.43 0.46 0.45

Figure 8. The HPLC chromatogram of fraction 4 and pure -linoleic acid ethyl ester 6.54 6.58 6.56
HgNH2CL; Chromatographic conditions: Shimadzu LC-3A
HPLC chromatograph; Detectors: UV detector, 270 nm; Liquid paraffin 4.52 4.42 4.47
Column: SHIMPACK GPC-801 (30 cm length, 0.8 cm i.d., Water 31.83 31.75 31.79
polystyrene 6 m); Mobile phase: THF; Flow rate: 1.0
ml/min. Column temperature: 25C.
linoleic acid, linoleic acid methyl ester and -linoleic
3.5. Quantitative Results acid ethyl ester.
An analysis method to effectively determine composi-
The compositions of sample were quantified by the tions of unknown cosmetic was established. The method
chromatographic external standard method and calcula- has a certain universal to analyze other cosmetics.
tion formula as follows.
C x % Cex % Sx Sex Vx Wx Iex I x- (1)
5. Acknowledgements
In which Cx% is the content of component x and the The authors gratefully acknowledge the support from the
unit of Cx% is the weight percentage. Cex% is content of Natural Science Foundation China (20677065) and ex-
corresponding standard and the unit of Cex% is the tend their gratitude to Yang Li from Institute of Coal
weight in 100 ml. Sx and Sex are the chromatographic Chemistry, Chinese Academy.
responses of component x and external standard, respec-
tively. Vx is the volume of fraction containing compo- 6. References
nent x, Wx is the total weight amount of cosmetic. Iex and
Ix- are the chromatographic injection amounts of compo- [1] M. T. Matyska, J. J. Pesek and L. Yang, Screening
nent x and external standard, respectively. Method for Determining the Presence of N-Nitrosodi-
The quantitative results of components were listed in ethanolamine in Cosmetics by Open-Tubular Capillary
Electrochromatography, Journal of Chromatography A,
Table 1. Through qualitative and quantitative analysis, a Vol. 887, No. 1-2, 2000, pp. 497-503.
more complete profile of a cosmetic was known. It doi:10.1016/S0021-9673(00)00451-9
should be noted, these main key compositions of cos- [2] T. R Ren and T. Vinod, Quantitative Determination of
metic were tested only and the quantitative results were Formaldehyde in Cosmetics Using a Combined Solid-
only preliminary, and the issues of these deficiencies Phase Microextraction-Isotope Dilution Mass Spectrome-
need further study. try Method, Journal of Chromatography A, Vol. 1029,
No. 1-2, 2004, pp. 217-222.
doi:10.1016/j.chroma.2003.12.054
4. Conclusions
[3] M. R. Lee, C. Y. lin, Z. G. Li and T. F. Tsai, Simulta-
neous Analysis of Antioxidants and Preservatives in Cos-
The joint application of multiple determination including
metics by Supercritical Fluid Extraction Combined with
HPLC, XRD and FTIR determination and solvent extrac- Liquid Chromatography-Massspectrometry, Journal of
tion was an effective analysis method to study cosmetic. Chromatography A, Vol. 1120, No. 1-2, 2006, pp. 244-
The main compositions of cosmetic were defined as 251. doi:10.1016/j.chroma.2006.01.075
mercuric ammonium chloride, liquid paraffin, 1,2-pro- [4] X. F. Wang, W. F, Zhang, J. Wei and R. Pen, Simulta-
panediol, glycerin, polyethylene glycol 200, stearic acid, neous Determination of Seven Sexual Hormones in Es-

Copyright 2011 SciRes. AJAC


862 C. M. ZHANG ET AL.

sential Oil by Performance Liquid Chromatography with [11] N. Lewen, S. Mathew, M. Schenkenberger and T. Rag-
Diode and Fluorescence Detectors, Chinese Journal of lione, A Rapid ICP-MS Screen for Heavy Metals in
Chromatography, Vol. 27, No. 3, 2009, pp. 328-332. Pharmaceutical Compounds, Journal of Pharmaceutical
[5] Q. Zhang, C. Wang, X. Wang, T. Wu and Q. Ma, De- and Biomedical Analysis, Vol. 35, No. 4, 2004, pp. 739-
termination of Common Antibiotics and Metronidazole in 752. doi:10.1016/j.jpba.2004.02.023
Cosmetics by Ultra Performance Liquid Chromatogra- [12] B. Passariello, M. Barbaro, S. Quaresima and A. Cas-
phy-Tandem Mass Spectrometry, Chinese Journal of ciello and A. Marabini, A Determination of Mercury by
Chromatography, Vol. 27, No. 5, 2009, pp. 237- 239. Inductively Coupled Plasma-Mass Spectrometry, Mi-
[6] M. Padilla, M. Palma and C. G. Barroso, Determination crochemical Journal,Vol. 54, No. 4, 1996, pp. 348-354.
of Phenolics in Cosmetic Creams and Similar Emul- doi:10.1006/mchj.1996.0110
sions, Journal of Chromatography A, Vol. 1091, No. 1-2, [13] V. Majidi and N. J. MillerIhlib, Two Simple Interface
2005, pp. 83-88. Designs for Capillary Electrophoresis-Inductively Cou-
[7] O. Evans and G. D. McKee, Determination of Mercury pled Plasma Mass Spectrometry, Analyst, Vol. 123,
(L1) and Organ Mercury Compounds by Reversed-Phase 1998, pp. 803-808. doi:10.1039/a707770j
Liquid Chromatography with Reductive Electrochemical [14] T. H. Lee and S. J. Jiang, Determination of Mer- cury
Detection, Analyst, Vol. 113, 1988, pp. 243-246. Compounds by Capillary Electrophoresis Inductively
doi:10.1039/an9881300243 Coupled Plasma Mass Spectrometry with Microconcen-
[8] M. Fujita and E. Takabatake, Continuous Flow Reduc- tric Nebulization, Analytica Chimica Acta, Vol. 413, No.
ing Vessel in Determination of Mercuric Compounds by 1-2, 2000, pp. 197-205.
Liquid Chromatography/Cold Vapor Atomic Absorption doi:10.1016/S0003-2670(00)00807-2
Spectrometry, Analatical Chemistry, Vol. 55, 1983, pp. [15] L. V. Gudzenko, R. P. Pantaler and A. B. Blank, Deter-
454-457. doi:10.1021/ac00254a011 mination of Arsenic with Michlers Thioketone, Journal
[9] S. E Birnie, Automated Continuous Monitoring of Inor- of Analytical Chemistry, Vol. 56, No. 8, 2001, pp. 721-723.
ganic and Total Mercury in Wastewater and Other Waters doi:10.1023/A:1016729525970
by Flow-Injection Analysis and Cold-Vapor Atomic Ab- [16] E. P. C. Lai, W. Zhang, X. Trier, A. Georgi, S. Kowalski,
sorption Spectrometry, Journal of Automatic Chemistry, S. Kennedy, T. M. Muslim and E. Dabek-Zlotorzynska,
Vol. 10, No. 3, 1988, pp. 140-143. Speciation of Mercury at ng/ml Concentration Levels by
doi:10.1155/S1463924688000264 Capillary Electrophoresis with Amperometric Detection,
[10] J. M. F. Costa-Fernandez and L. R. A. Pereiro-Garcia, Analytica Chimica Acta, Vol. 364, No. 1-3, 1998, pp.
Direct Coupling of High-Performance Liquid Chroma- 63-74. doi:10.1016/S0003-2670(98)00147-0
tography to Microwave-Induced Plasma Atomic Emis- [17] C. M. Zhang, A. Y. Li,Y. Li and L. M. Zhang, Instru-
sion Spectrometry via Volatile-Species Generation and mental Analysis and Systematic Investigation of Heavy